Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AUTOMATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74Linked to original sources

Do automated calls with nurse follow-up improve self-care and glycemic control among vulnerable patients with diabetes?

PURPOSE: We sought to evaluate the effect of automated telephone assessment and self-care education calls with nurse follow-up on the management of diabetes. SUBJECTS AND METHODS: We enrolled 280 English- or Spanish-speaking adults with diabetes who were using hypoglycemic medications and who were treated in a county health care system. Patients were randomly assigned to usual care or to receive an intervention that consisted of usual care plus bi-weekly automated assessment and self-care education calls with telephone follow-up by a nurse educator. Outcomes measured at 12 months included survey-reported self-care, perceived glycemic control, and symptoms, as well as glycosylated hemoglobin (Hb A1c) and serum glucose levels. RESULTS: We collected follow-up data for 89% of enrollees (248 patients). Compared with usual care patients, intervention patients reported more frequent glucose monitoring, foot inspection, and weight monitoring, and fewer problems with medication adherence (all P -0.03). Follow-up Hb A,, levels were 0.3% lower in the intervention group (P = 0.1), and about twice as many intervention patients had Hb A1c levels within the normal range (P = 0.04). Serum glucose levels were 41 mg/dL lower among intervention patients than usual care patients (P = 0.002). Intervention patients also reported better glycemic control (P = 0.005) and fewer diabetic symptoms (P <0.0001 ), including fewer symptoms of hyperglycemia and hypoglycemia. CONCLUSIONS: Automated calls with telephone nurse follow-up may be an effective strategy for improving self-care behavior and glycemic control, and for decreasing symptoms among vulnerable patients with diabetes.

Adult↗

Robotic automation performs a nested RT-PCR analysis for HCV without introducing sample contamination.

The Polymerase Chain Reaction (PCR) is a popular method to amplify and detect specific RNA and DNA sequences. To obtain maximum performance of PCR, it is best performed by highly skilled technologists because of the complexity of the assay and the potential for laboratory contamination from the amplification products produced. We chose to automate this nested RT-PCR for hepatitis C assay to significantly reduce the need for manual pipetting while preserving the excellent non-contamination performance of the corresponding manual test. A three axis cartesian robotic pipetting station was equipped to perform RT-PCR using an on-board automated thermal cycling device. 104 sera were analyzed using this modified pipetting station and we found a very close agreement (100% sensitivity and 98% specificity) with results previously obtained by corresponding manual RT-PCR analysis. This study demonstrated a user-programmed robotic pipetting system could successfully automate a complex PCR assay without contamination. Our results suggest that use of robotic pipetting station can provide cost efficient alternative to performance of molecular diagnostic assays while demonstrating minimal inter sample contamination.

Electrophoresis, Agar Gel↗

Fully-automated spectrophotometric method for measurement of antioxidant activity of catalase.

OBJECTIVES: Develop fully automated assay of antioxidant catalatic activity of catalase. DESIGN AND METHODS: The assay is based on standard, clinical chemistry automated analyzer methods for measuring hydrogen peroxide by using the Trinder reagent. Catalase competes with 324 U/L horseradish peroxidase (type XII) and Trinder reagent for hydrogen peroxide produced by 46 U/L uricase action on urate. Unit activity is defined as 50% inhibition of maximal color development. RESULTS: Within-run coefficients of variation (cv) were 2% for standards and samples, whereas between-run cv was 3.1% for standards and 7.3% for samples. Dilutional parallelism and linearity were demonstrated for 8-fold dilutions of samples over the range 0.1 to 1.1 U/mL. Recovery of added catalase was complete. Samples are stable to freezing and storage for 1 week at -80 degrees C. Activities (units/mL) ranged from 0.29 to 0.41 in human and canine plasma, and for erythrocytes from 48 to 70 in man, 17 to 19 in dogs, and 60 to 89 in rats. Rat liver activity (units/g wet weight) was age-dependent and ranged from 17 to 24 at 2 months, and from 19 to 37 at 6 months. CONCLUSION: The first, fully automated assay for the measurement of catalatic activity of catalase in plasma, erythrocytes, and liver is demonstrated for multiple species. The assay is simple, precise, relatively inexpensive, and rapid.

Animals↗

Automated determination of urine and cerebrospinal fluid proteins with Coomassie Brilliant Blue and the Abbott ABA-100.

We have evaluated the use of Coomassie Brilliant Blue (CBB) dye to measure the protein of urine and cerebral spinal fluid. The method was automated and compared with the turbidimetric method and with Ponceau S dye. With both the manual and automated procedures the CBB method could be used to protein concentrations of 160 mg/dl. Comparing this method to the method measuring the turbidity produced by trichloracetic acid (TCA) we found a correlation coefficient (r) of 0.96. The regression line was CBB = 0.84 TCA + 4.97. A similar comparison to the method using Ponceau S (PS) produced an r = 0.98 and the regression line, CBB = 0.91 P-S + 3.2. The CBB method was not as affected by turbidity in the samples or by xanthochromia as was the TCA Method. It is simpler to perform than the P-S method, since it does not require decantation. With the manual method, the coefficient of variation (CV) at 40 mg/dl for within-day determinations was less than 2% and, for between-day determinations, less than 4%. While the CV was somewhat higher with the ABA than with the manual method at 40 mg/dl, it was below 5% for both within-day and between-day determinations at the concentrations between 70 and 170 mg/dl. The method using CBB is useful as both a manual and automated procedure to measure protein in urine and cerebral spinal fluid.

Autoanalysis↗

Clinical value of using an automated sperm morphology analyzer (IVOS).

OBJECTIVE: To determine the clinical value of automated normal sperm morphology outcomes. DESIGN: Prospective clinical study. SETTING: Clinical and research assisted reproduction laboratory. PATIENT(S): Two hundred seven GIFT cycles. INTERVENTION(S): The wife was induced to superovulate, laparoscopically aspirated, and the gametes were transferred laparoscopically. The husband's sperm morphology was evaluated with use of a sperm morphology analyzer using the strict criteria classification system. MAIN OUTCOME MEASURE(S): Normal sperm morphology, IVF, and pregnancy outcomes. RESULT(S): The logistic regression model showed that normal sperm morphology was significantly associated with fertilization in vitro, as dependent (age) and independent variables. Analyzing the fertilization rates across the 5% normal sperm morphology cutoff point, a fertilization rate of 39.39% (< or = 5%) compared with 62.92% (>5%) was obtained. The logistic regression model showed that normal sperm morphology was also a significant predictor of pregnancy when allowing for the number of oocytes transferred and female age. Analyzing the pregnancy rates across the 5% normal sperm morphology cutoff point, pregnancy rates of 15.15% (< or = 5%) and 37.36% (>5%) were obtained. CONCLUSION(S): Normal sperm morphology as evaluated by the automated semen analyzer (IVOS) was shown to adhere to the same fertility cutoff point (5%), as determined by the manual evaluation of sperm morphology. Automated normal sperm morphology outcomes also were found to be significant predictors of IVF and pregnancy in a GIFT program.

Adult↗

Automated phenylthiocarbamyl amino acid analysis of carboxypeptidase/aminopeptidase digests and acid hydrolysates.

A fully automated exopeptidase digestion procedure for the partial determination of N- and C-terminal peptide/protein sequence is described. The digestion of various substrates with aminopeptidase M, carboxypeptidase A, P or Y was accomplished with the Varian 9090 autosampler's robotic automix routines. The released free amino acids, in addition to free amino acids from acid hydrolysates, were derivatized with phenylisothiocyanate in an automated fashion and subsequently chromatographed on a C18 column for separation and quantitation. The advantages of automating this precolumn phenylisothiocyanate derivatization are the virtual elimination of sample manipulation errors and very reproducible data due to the precise control of the reaction conditions both of which, facilitate the interpretation of the exopeptidase reaction kinetic data.

Amino Acids↗

Performance of an automated real-time ST-segment analysis program to detect coronary occlusion and reperfusion.

Continuously updated ST-segment recovery analysis has been shown to accurately predict infarct-related artery patency. Salient principles were converted into algorithms and incorporated into a portable ST monitor for optimal application. This study tested the automated program's ability to detect occlusion and reperfusion during balloon angioplasty. ST-segment recordings during 78 balloon occlusions in 31 patients were analyzed. The program requires at least one electrocardiogram with ST elevation of 200 microV or greater in the recording, caused by the current occlusion or by a previous occlusion, before it will yield a patency prediction. All 35 inflations causing peak ST elevation of 200 microV or more were indeed detected. All five inflations causing less than 200 microV ST elevation preceded by an inflation causing 200 microV or higher ST elevation were also detected. Occlusion was detected a median of 40 seconds after inflation, and reperfusion a median of 17 seconds after deflation. Peak ST elevation greater than 200 microV occurred in 19 of 26 left anterior descending artery inflations (73%), 1 of 22 left circumflex artery LCX inflations (5%), and 15 of 30 right coronary artery inflations (50%). Five different leads identified peak ST elevation through 12-lead surveillance. In this model of coronary occlusion during angioplasty balloon inflation, the automated patency assessment program appears to detect coronary angioplasty balloon occlusion and reperfusion within seconds in all occlusions causing a peak ST elevation of 200 microV or greater. Testing this automated patency assessment program as a noninvasive triage tool in myocardial infarction patients seems warranted.

Adult↗

An automated multi well cell track system to study leukocyte migration.

Design of automated image processing systems to determine migration characteristics of individual cells is not trivial. Every test sample requires separate recording and the analysis of individual cell tracks in two- or three-dimensional migration systems by time-lapse microscopy is extremely laborious. Here, we describe a new Automated Cell Track System (ACTS). In addition to contrast differences, which are used by existing analysis systems, the ACTS algorithms recognize cells on the basis of morphological similarities in successive images and adapt to the continuous shape changes of individual cells during migration. The system facilitates simultaneous analysis of multiple cells and the measurement of multiple wells in one single experiment. We validated the system studying HSB-2 T cell migration in standard 96-well microtiter plates coated with ICAM-1-Fc protein or control CD14-Fc protein. Migration of HSB-2 T cells on ICAM-1-Fc is Leukocyte Function-associated Antigen-1 (LFA-1)-mediated and both the number and the speed of migrating cells depend on the ICAM-1-Fc concentration. We show that automated analysis of the migration data yields similar results as manual analysis, but in a fraction of the time. We conclude that this system is extremely well suited to precisely monitor the migratory behavior of individual cells. The analysis of multiple wells in parallel makes this set-up appropriate in high throughput screening in which multiple components are simultaneously tested for their effect on cell migration.

Algorithms↗

Particle counting assay for anti-toxoplasma IgG antibodies. Comparison with four automated commercial enzyme-linked immunoassays.

An assay for anti-toxoplasma IgG antibodies based on agglutination of latex particles was set up and compared with commercial immunoassays. The reaction was measured by instrumental counting of particles remaining unagglutinated. The running time was 45 min. This test (PaC) was compared using 243 serum samples with four automated commercial immunoassays: the Enzymum test Toxo IgG (ES300, Boehringer), the Vidas Toxo IgG (Biomérieux), the IMX Toxo IgG (Abbott), the Magia Toxoplasma gondii IgG (Merck). The mean values (+/- SD) obtained by IMX (25 IU +/- 68) and ES300 (45 IU +/- 142) were significantly lower than the values obtained by Vidas (73 IU +/- 237, p < 10(-4) and p = 0.006, respectively), by Magia (80 IU +/- 300, p < 10(-4) and p = 0.0005) and by PaC (70 IU +/- 260, p < 10(-4) and p = 0.0126). The correlations between PaC and Toxo IgG Boehringer, Biomérieux, Abbott, Merck were r = 0.97, r = 0.98, r = 0.94, r = 0.98, respectively. The correlation coefficients between the enzyme-immunoassays ranged from 0.96 to 0.99. All positive samples by PaC were found to be positive by enzyme-immunoassays except for eight sera which were doubtful positives by the Enzymum test ToxoIgG from Boehringer. No negative sample by PaC was found positive by any of the enzyme-immunoassays. In PaC, when two latex preparations coated with different antigen were compared, the correlation was rather weak (r = 0.93) suggesting that the selection of the antigen can be critical. In conclusion, the four automated commercial immunoassays now available gave similar results. However, the discrepancies observed in this study underlined the importance of clinical and biological follow-up of the patients and the necessity to confirm the result. The introduction of a new technique such as PaC, which is now available for a large variety of assays in Clinical Chemistry and Microbiology, is justified by its intrinsic advantage of homogeneity. Therefore, automation is easy as well as the control of possible interference.

Animals↗

Automated erythrocytopheresis for relief of priapism in sickle cell hemoglobinopathies.

Priapism, a complication of male patients with sickle hemoglobinopathies, has been managed by a variety of surgical and nonsurgical forms of therapy that often are unsuccessful. The application of automated erythrocytopheresis (red blood cell exchange) by continuous-flow and semicontinuous-flow procedures appears to offer distinct advantages in the treatment of complications resulting from sickle hemoglobinopathies. The successful application of erythrocytopheresis for the relief of priapism in a patient with hemoglobin SC disease is presented and probably represents the first case reported on the use of automated red blood cell exchange procedures in the treatment of this condition. Data and results of automated erythrocytopheresis in 4 additional patients are presented. The advantages and disadvantages of erythrocytopheresis in the treatment of priapism (and other complications of sickle hemoglobinopathies) are discussed and the method is compared to other modes of therapy.

Adult↗

Automated tracing and change analysis of angiogenic vasculature from in vivo multiphoton confocal image time series.

Automated methods are described for tracing and analysis of changes in angiogenic vasculature imaged by a multiphoton laser-scanning confocal microscope. Utilizing chronic animal window models, time series of in vivo 3-D images were acquired on approximately the same target volume of the same specimen while undergoing angiogenic change (typically every 24 h for 7 days). Objective, precise, 3-D, rapid, and fully automated vessel morphometry was performed using an adaptive tracing algorithm that is based on a generalized irregular cylinder model of the vasculature. This algorithm was found to be not only adaptive enough for tracing angiogenic vasculature, but also very efficient in its use of computer memory, and fast, taking less than 1 min to trace a 768 x 512 x 32, 8-bit/pixel 3-D image stack on a Dell Pentium III 1-GHz computer. The automatically traced centerlines were manually validated on six image stacks and the average spatial error was measured to be 2 pixels, with an average concordance of 81% between manual and automated traces on a voxel basis. The tracing output includes geometrical statistics of traced vasculature and serves as the basis of statistical change analysis. The computer methods described here are designed to be scalable to much larger hypothesis testing studies involving quantitative measurements of tumor angiogenesis, gene expression relative to known vascular structures, and impact of drug delivery.

Algorithms↗

Comparative material on automated and semiautomated perimeters-1983.

In reviewing all the responses from the private practitioners and clinicians in Departments of Ophthalmology throughout the United States and Canada, it would appear that the majority of individuals are quite happy with the automated perimeters they have purchased. Clinicians should be aware that this is a rapidly changing field and several devices which were previously available are no longer being manufactured. In addition, because of the competition which has recently developed in the automated perimetry industry, prices are continuing to come down. Some practitioners have been unhappy with the fact they paid a higher price for a device which is currently selling at a lower price. However, a similar phenomenon has happened in the computer world and is to be expected as competition increases. The major problems which seem to be of concern to all ophthalmologists, are the difficulty in interpreting data and the management of the data. We believe one of the major frustrations of all practitioners using automated perimeters relates to the fact that this is a totally new technique, which requires time and practice to gain familiarity. In general, it would appear that most of the practitioners have been happy with the service provided by various companies, although there are a few exceptions. Read the enclosed responses and develop your own conclusions. We hope you find the information useful.

Catalogs, Commercial as Topic↗

Evaluation of diagnostic capabilities of interactive test strategies in automated perimetry.

Simple strategies for visual field screening with automated perimeters can detect abnormalities at acceptable rates. However, the information available from a screening field chart is often insufficient to assign the field into a diagnostic category, and further field testing is necessary. Automated perimeters can be programmed to alter the suprathreshold stimulus intensity based on patient response or do further testing in areas of detected abnormality. Two such programs were compared to a simple screening method using a single automated perimeter in 75 eyes. The charts generated by the interactive programs were more diagnostically useful than those produced by the simple strategy. However, these interactive strategies produced an increased rate of false alarms and testing time which substantially reduced their value as screening visual field tests.

Evaluation Studies as Topic↗

A prospective three-year study of response properties of normal subjects and patients during automated perimetry.

PURPOSE: The purpose of this study is to evaluate prospectively the reliability characteristics of patients undergoing automated perimetry over a 3-year period and compare these results with the results of previous investigations. METHODS: The subjects included 48 normal observers, 32 ocular hypertensive subjects, and 19 patients with early glaucomatous visual field loss. Both eyes were tested annually for 3 years with automated perimetry, using the standard procedures for the Humphrey Field Analyzer. Fixation losses, false-positive errors, false-negative errors, and short-term variability (double determinations) were evaluated. RESULTS: Short-term variability was slightly higher for the early glaucoma group than for the normal observer and ocular hypertensive groups, but there were no meaningful changes in short-term variability over 3 years. False-positive errors were very low in all three groups throughout the investigation. False-negative errors were slightly higher in the early glaucoma group, but all three groups had relatively low false-negative error rates throughout the study. Fixation losses were the most common source of unreliable results. The number of fixation losses decreased for the second and third years of the study. CONCLUSION: Contrary to a previous report, a relatively low number of unreliable tests were found for both initial and follow-up visits. The majority of unreliable visual field tests were sporadic events. Only a few subjects repeatedly produced unreliable test results. The authors conclude that automated perimetry can provide a reliable means of following patients over extended periods of time.

Adult↗

Automated surgical equipment requires routine disinfection of vacuum control manifold to prevent postoperative endophthalmitis.

PURPOSE: Contamination of automated surgical equipment is a potential source of postoperative endophthalmitis. The effect of disinfecting the unsterile vacuum control manifold (VCM) on contamination of the aspiration fluid was studied. DESIGN: Comparative prospective microbiologic contamination study. SPECIMENS AND CONTROLS: The 37 aspiration fluid specimens studied or examined consisted of 25 from three automated evacuation systems equipped with an internal VCM (experimental groups) and 12 from one system equipped with a modified external VCM (control group). In addition, the tubings of two internal VCMs were investigated. METHODS: We investigated aspiration fluid specimens from routine cataract and vitrectomy operations performed with automated evacuation systems. After tracing the source of contamination to the internal VCM, the system was modified, creating an external VCM with the possibility for disinfection, and the study was continued. Whereas no sterilizing rinsing procedures were applied to the hidden internal VCM, the modified external VCM was regularly rinsed and filled overnight with 70% isopropanol. All samples were collected under sterile conditions, centrifuged, and cultured for bacterial growth on blood agar and MacConkey agar for 24 to 48 hours at 37 degrees C. The samples of the two internal VCMs were cultured for fungi as well. MAIN OUTCOME MEASURES: Bacterial growth was quantified, and bacteria and fungi were isolated and identified according to standard microbiologic procedures. RESULTS: In all aspiration fluid specimens from internal VCM-systems, 2+ to 4+ bacterial growth was found. Pseudomonas-related genera (Stenotrophomonas maltophilia, 17x; Comamonas acidovorans, 8x; Chryseomonas spp., 3x), Agrobacterium radiobacter (1 3x), Flavobacterium spp. (3x), and Micrococcus luteus (7x) were found most frequently. The tubing of the two VCMs contained biofilms exhibiting several of these bacteria and fungi. All specimens from the modified external VCM-system remained sterile. There was a significant difference with regard to the frequency of contamination of the aspiration fluid between the experimental and control groups (chi-square: P = 0.0001). CONCLUSIONS: The technical modification described herein allows facile hygienic measures, by which contamination of aspiration fluid by the VCM can be eliminated, which otherwise can be a significant source of contamination.

Aqueous Humor↗

An extended boiling method for small-scale preparation of plasmid DNA tailored to long-range automated sequencing.

Automated fluorescence sequencing depends on high-quality plasmid DNA, which is conveniently prepared by minipreparation procedures. While those procedures are effective for high-copy number plasmids, purity and yields of low-copy number plasmids are often not sufficient to achieve reasonable sequencing results. Here, we describe a reproducible and cheap procedure for the small-scale preparation of plasmid DNA, which is based on the original Holmes and Quigley protocol, comprising a boiling and two selective precipitation steps. Besides various other modifications, this procedure utilizes polyethylene glycol (PEG) precipitation as a key step to further purify plasmid DNA tailored to automated fluorescence sequencing. Independent of the plasmid size and copy number, the modified procedure yields plasmid DNA, which gives average reading lengths of 800 and more bases with a standard fluorescence cycle sequencing protocol. To demonstrate the efficiency and reproducibility of the method, sequencing data of various human interleukin-6 gene variants cloned in different vectors are presented. This procedure offers an economical alternative to commercial miniprep kits, utilizing silica resins or anion-exchanger matrices and, moreover, is more reliable and consistent with respect to reading lengths and accuracy in automated fluorescence sequencing.

Base Sequence↗

Evaluation of an improved automated analysis of freezing behaviour in rats and its use in trace fear conditioning.

Pavlovian fear conditioning in rodents often involves the assessment of freezing behaviour. Since human-based scoring is labour-intensive and subject to biases, several automated methods have been proposed, but few of them have been assessed for temporal definition. An accurate method for the automated analysis of freezing in rats is presented. It is based on a comparison of contrast from successive video images (Learn. Mem. 7 (2000) 58). A major improvement involves subtracting a previously recorded image of the empty background from each frame before processing. This simple operation greatly improves reliability, since it cancels the influence of video noise outside the region of interest in the image (the rat), and can also take advantage of the movements of a patterned animal over a textured background. The technique is compared with manual scoring and with the Anagnostaras method in a trace fear conditioning experiment. The method is appropriate to monitor the time course of freezing behaviour. The same system with a different threshold can also score locomotor activity. A quantitative evaluation of the residual errors inherent to automated methods is attempted.

Algorithms↗

Semi-automated analysis of NMDA-mediated toxicity in digitised colour images from rat hippocampus.

The evaluation of neuronal cell survival after, for example, mechanical, hypoxic or drug-mediated injury requires the analysis of a high number of histological specimens. Since this is a time-consuming occupation, we have developed a semi-automated analysis routine for the determination of the distribution of live and dead cells. After digitalization of the histological preparations, 8-bit colour bitmaps were assessed using a compiled image-analysis programme of the software package Khoros. In the current study a detailed example of the application of this image-processing approach is described for the investigation of the cell survival after intraventricular application of N-methyl-D-aspartate (NMDA). The samples were prepared as fuchsin acid/toluidine blue stained hippocampal thin slices. The calculated areas of the live and dead cells were highly correlated with manual counts of live and dead cells in the 100 samples examined in this study. Twenty-four hours following NMDA-treatment animals (n = 5) were found to have significantly fewer live and more dead hippocampal cells than the saline-treated animals (n = 5), using either automated or manual examination techniques. The automated technique also revealed that NMDA treatment resulted in a reduction in the density of live cell distribution.

Animals↗