Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74Linked to original sources

An in-vitro study of the effects of various disinfectants on prosthetic and surface materials.

OBJECTIVE: This study assessed the effect of various disinfectants on several contaminated prosthetic and surface-covering materials. METHODS: The efficacy of 6 disinfectants used at King Abdulaziz University, Jeddah, Kingdom of Saudi Arabia, on prosthetic and surface-covering materials, irreversible hydrocolloid and elastomer impression materials, wax, acrylic resin, metal, bench-covering material, and floor carpet. These materials were contaminated with Pseudomonas aeruginosa, Escherichia coli, and Staphylococcus aureus. Counts of viable bacteria on the materials was determined by incubated replica plating on blood agar plates at 5 minute intervals. A 3 way non parametric analysis of variance was used to evaluate the main effects and interactions of the disinfectants, bacteria, and materials. RESULTS: Statistical analysis showed that material, type of disinfectant, and interactions between material and bacteria were significant. Carpet has a significantly higher bacterial count than many other items (P < 0.0001) such as acrylic resin, irreversible hydrocolloid, chrome-cobalt casting, and laminated bench surfaces. CONCLUSION: Quaternary ammonia compound and the tertiary ammonia phenol were the most effective disinfectants. Efficacy of the disinfectant depends partly on the bacteria used for contamination. Carpets in dental clinics showed high potential to retain microorganisms.

Colony Count, Microbial↗

Acrylic denture distortion following double processing with microwaves or heat.

The present study compared the fit of acrylic resin bases subjected to two curing cycles in a water-bath or in a microwave oven. Resin bases were processed on duplicate stone casts prepared from a cobalt chromium master die. Ten bases, composed of conventional polymethylmethacrylate, were cured in a water-bath for 7 h at 70 degrees C and 3 h at 100 degrees C, and a further 10 cured in a domestic microwave oven at 65 W for 25 min. Ten bases composed of polymethylmethacrylate modified by means of a chemical activator were cured at 100 degrees C in a water-bath for 20 min. All bases were then subjected to a second curing cycle following addition of new acrylic resin to the alveolar ridge areas. Following each curing cycle the fit of the posterior border of each base was evaluated. A silicone impression material was used to form indices between the bases and the master die, these were then invested in stone and sectioned to allow cross-sectional measurement by means of an eyepiece micrometer. A one-way analysis of variance and unpaired Student's t tests were employed to compare the differences in distortion of the three groups. The differences in distortion between the first and second curing cycles were significant for all curing methods (P less than 0.001). However, microwave curing caused significantly less distortion of the denture base than short water-bath curing, especially in the centre of the palate (P less than 0.001).

Analysis of Variance↗

[Analysis of morphological variations of the maxilla in unilateral complete cleft lip and palate after presurgical orthopedic treatment by a functional obturating plate].

BACKGROUND: The authors' aim is to show, through a morphological analysis, how the use of a passive functional plate in hard acrylic resin can guide the growth of the maxillary segments in babies born with cleft lip and palate. METHODS: The authors have obtained, with a scanner gray scales, bidimensional monochromatic images of nine babies' dental casts with cleft lip and palate at birth and at the time of the first cheilo-rhinoplastic surgery. A graphic analysis on these images was made comparing the charts drawn by Bolter's points identified on the maxillary alveolar arch. RESULTS: The overlapping of the graphic analysis of the mean of values recorded at birth and after the application of the functional passive plate in hard acrylic resin shows how it is possible to promote the growth of maxillary alveolar arch with unilateral complete cleft. CONCLUSIONS: The authors believe that the presurgical orthopedic functional treatment can lay the bases for a symmetric and balanced skeletal growth of the cleft maxillary. This treatment will promote a better future occlusal relationship. It's also pointed out how this functional approach can favour plastic surgery in reducing cleft's size.

Age Factors↗

In vitro color stability, stain resistance, and water sorption of four removable gingival flange materials.

STATEMENT OF PROBLEM: Evaluation of the color stability of materials used for removable gingival flange prostheses may provide information on their serviceability. PURPOSE: This in vitro study compared the color stability, stain resistance, and water sorption of 4 materials commonly used for gingival flange prostheses. MATERIAL AND METHODS: Forty-five cylindrical disks (15 mm in diameter and 10 mm thick) were fabricated out of 1 silicone (Gingivamoll), 1 copolyamide (Flexite Supreme), and 2 heat-polymerized acrylic resins (QC-20 and Vertex). Ten specimens of each material were evaluated by a spectrophotometer after 7, 14, 30, 60, 120, and 180 days of immersion in staining solutions of coffee and tea, whereas specimens placed in water and exposed to air, served as controls. Color differences before staining and after storage periods were assessed. Another 5 specimens of each material were tested for water sorption after 56 days. Data for color change (DeltaE) and weight difference (DeltaW) were analyzed by use of a repeated measures analysis of variance and Scheffe's multiple comparisons (alpha=.05). RESULTS: The coffee solution produced the highest discoloration value in the silicone material (DeltaE=7.31 +/- 0.57, P<.001), followed by the copolyamide (DeltaE=4.22 +/- 0.40, P<.001), and 2 acrylic resins. In the tea solution, the copolyamide had the greatest staining (DeltaE=2.74 +/- 0.56), whereas the other materials had smaller color changes (P<.001). All investigated materials were relatively color stable (DeltaE < 2) when stored in air and water for 6 months. The copolyamide material showed the greatest water uptake, whereas silicone adsorbed the least water (P<.001). CONCLUSIONS: All flange materials tested demonstrated color stability in air and water. However, the color changes of silicone and copolyamide materials stored in coffee solution for 180 days were greater than 3 NBS (National Bureau of Standards) units, which would be characterized as appreciable and considered clinically unacceptable.

Absorption↗

Immediate replacement removable partial dentures with cobalt-chromium frameworks: rationale, technology and a case report.

The advantages of removable partial dentures with cobalt-chromium frameworks over those made entirely of acrylic resin, in oral health and hygiene, are well documented. However, in cases where teeth are to be extracted for fitting the removable partial denture, a difficulty arises because of the need to test the fit of the removable partial denture framework. The advent of two modern technologies-- laser welding and metal bonding agents -- make it possible to test the fit of the major part of the framework prior to adding additional metal components to support artificial teeth. A case is described in which the four lower incisors were extracted. The main part of the framework was constructed and its fit tested. A second casting was laser-welded to the lingual plate of the first casting to support the artificial incisor teeth. This technique avoids the need to make an acrylic resin temporary denture but incurs the cost of the additional technical work and so the advantages may be considered to be economically neutral.

Adult↗

Bond strength variation of synthetic resin teeth in dentures.

The bond strength of denture teeth to acrylic resin denture bases was determined by producing tensile test specimens from standardised and anonymously presented partial dentures. Ten dentures were produced by randomly selected commercial dental laboratories and five were produced in a university dental laboratory. The tooth debonding forces exhibited a wide range of variation both within and between dentures. The university-produced dentures showed, on average, a slightly improved tooth bond strength. This study highlights the need for further investigation of this problem and for the development of a standardised technique to provide satisfactory denture tooth bonding.

Acrylic Resins↗

Thermomechanical investigation of poly(methylmethacrylate) containing an organobismuth radiopacifying additive.

Previously we demonstrated the feasibility of using up to 24% triphenylbismuth (TPB) as a radiopaque, monomer-miscible additive for dental acrylic resins. In this study we examined the influence of TPB on thermomechanical properties of a representative polymethylmethacrylate (PMMA) ambient-cured resin used for temporary dental crowns and bridges. TPB (0%, 5%, 15% or 30% w/w) was dissolved in the monomer component, added to the powder component, and allowed to cure in rectangular molds. After 1 h they were either stored at 23 degrees C for 23 h, or heated for 5 min at either 40 degrees C or 50 degrees C, and then stored for 23 h. They were then scanned from -10 degrees to 125 degrees C in a dynamic mechanical thermal analyzer using the three-point bending mode of deformation at 1-Hz frequency. The onset to the glass-transition temperature (Tg) is decreased by 13 degrees to 32 degrees C by addition of TPB, while the storage modulus (E') at 25 degrees C is either unchanged or is slightly increased. TPB did not interfere with the curing reaction, and postcure heating at 40 degrees C had no effect on either E' or Tg. However, heating at 50 degrees C generally increased Tg but had very little effect on E' throughout the 0-50 degree C operating temperature range. TPB crystals were observed to have precipitated at TPB levels above 8%. These crystals, dispersed throughout the PMMA, act as reinforcing fillers. This reinforcement can account for the lack of a decrease in E', as would be expected if TPB had a plasticizing effect below Tg. However, even at 5%, a concentration at which all the TPB remains dissolved in the solid polymer, no decrease in E' was observed. This implies that TPB exerts an antiplasticizing effect at temperatures below 50 degrees C, possibly by occupying free volume among the polymer chains. It is concluded that TPB, in amounts adequate to impart diagnostic levels of radiopacity, is unlikely to adversely affect the clinical utility of PMMA-based dental acrylic resins.

Biocompatible Materials↗

[Model investigation of push-out test used for quantitative evaluation of dental implant osseointegration].

A frequently used method for quantitative evaluation of implant-bone interface strength is the push-out test. The objective of the authors' study was to determine the effect of implants' geometric characteristics on the results of push-out method. The degree of osseointegration is determined by a complicated interaction of mechanical, biological and chemical factors. As this study focused on the effects of geometrical characteristics of dental implants, the authors tried to reduce the influence of biological and chemical factors as much as possible. For this reason a model of push-out test was set up. Cylindrical metal rods were imbedded in acrylic resin and were pushed out, meanwhile the force needed to disrupt the connection between the surface of the metal rods and the resin was measured and push-out strengths were calculated. Metal rods with three different lengths (7, 9, and 13 mm) and three different diameters (3.4, 4, 4.5 mm) were investigated. No correlation was found between implant length and maximum push-out strength. The mean push-out strengths were 17.32 MPa, 15.99 MPa and 15.56 MPa in groups, with 3.4, 4 and 4.5 mm diameter, thus the push-out strength decreases with increasing metal rod diameter. This may be attributed to the different distance between the outer circumference of the metal rods and the hole of the supporting table. Supporting this theory metal rods with identical diameter were examined, while the diameter of the hole on the supporting table was changed. The results demonstrated that larger holes on the supporting table resulted in higher push-out strengths. This indicates that comparisons of this variable should only be performed with standardized clearance of the hole on the supporting table. Push-out strengths of groups of cylindrical and conical implants with 9 degrees convergence were also investigated. The mean values were 16.57 MPa and 16.43 MPa, respectively. There was no statistically significant difference between the two groups. This means that results of experiments with all the above mentioned implant types are comparable, at least to that degree of conicity. As masticatory forces act usually on a surface, which is not perpendicular to the implant axis, we compared forces and push-out strengths that acted on surfaces with 10 degrees and 15 degrees inclination. The calculated average push-out strengths were 24.89 MPa and 22.56 MPa, respectively. More than twice as high push-out strengths were measured when threaded metal rods were compared to unthreaded ones (30.15 MPa, 14.89 MPa, respectively). Examining the effect of pitch of threads we compared the mean push-out strengths in three groups of threaded metal rods with pitch of threads 0.7, 1.0 and 1.25. The results were 28.86 MPa, 30.48 MPa, 31.12 MPa, respectively. The differences can be explained with the alteration in the dimension of the interface covered by the acrylic resin. Thus the effect of diameter, inclined opposing surface and threads must not be ignored if one compares the osseointegration capacity of different implants.

Dental Implantation, Endosseous↗

Evaluation of the accuracy of three techniques used for multiple implant abutment impressions.

STATEMENT OF PROBLEM: Movement of pick-up type impression copings inside the impression material during clinical and laboratory phases may cause inaccuracy in transferring the spatial position of implants from the oral cavity to the master cast. As a consequence, the laboratory technician may fabricate a restoration that requires corrective procedures. PURPOSE: This in vitro study evaluated the accuracy of 3 different impression techniques using polyether impression material to obtain a master cast for the fabrication of a prosthesis that would fit passively on multiple implants. MATERIAL AND METHODS: A machined metal model with 6 implants and abutments and a corresponding, passively fitting, matching metal template were fabricated. A total of 45 medium-consistency polyether impressions (Impregum Penta) of this model were made with pick-up type square impression copings. Three groups of 15 each were made with different impression techniques: in group 1, nonmodified square impression copings were used; in group 2, square impression copings were used and joined together with autopolymerizing acrylic resin before the impression procedure; and in group 3, square impression copings previously airborne particle-abraded and coated with the manufacturer-recommended impression adhesive were used. The matching metal template, which had been passively fit to the metal model so that it encountered no visually perceptible resistance or rocking on the abutments, was used as the control for evaluation of the accuracy of passive fit. A single calibrated and blinded examiner visually evaluated each cast. Positional accuracy of the abutments was numerically assessed with an optical scanner at original magnification x 10, which provided measurements to within 2 microm of the variations of the casts with respect to the horizontal distances between the 2 most posterior abutments and the 2 most anterior abutments. Data were analyzed with a 1-way analysis of variance at alpha=.05, followed by the Student Newman-Keuls method (P=.05). RESULTS: Visual examination of the casts from group 1 revealed discrepancies between 1 or more abutments and the metal template. Visual analysis of the master casts from groups 2 and 3 revealed close alignment of the metal template on all 6 abutments. One-way analysis of variance analyzed the numerical data obtained with the optical scanner and revealed significant differences among the 3 impression techniques (P<.001). The Newman-Keuls procedure disclosed significant differences between the groups, with group 2 and 3 casts being significantly more accurate than group 1 casts (P=.05). The distance between abutments 1 and 6 compared to the standard metal model was 33.83 microm (SD +/- 5.4) greater on group 2 casts, 31.72 microm (SD +/- 4.6) greater on group 3 casts, and 78.16 microm (SD +/- 22.14) greater on group 1 casts. Distances between the most anterior abutments were also greater than those recorded on the metal model. The distance was 31.42 microm (SD +/- 7.6) greater on group 2 casts, 30.34 microm (SD +/- 6.4) greater on group 3 casts, and 67.91 microm (SD +/- 15.34) greater on group 1 casts. CONCLUSION: Within the limitations of this study, improved accuracy of the master cast was achieved when the impression technique involved square impression copings joined together with autopolymerizing acrylic resin or square impression copings that had been airborne particle-abraded and adhesive-coated.

Air Abrasion, Dental↗

Rapid fixation and embedding method for immunocytochemical studies of tomato spotted wilt tospovirus (TSWV) in plant and insect tissues.

A new rapid fixation and embedding technique using microwave energy was evaluated for immunolabelling and examination of ultrastructure of plant and insect cells. Tissues in gluteraldehyde-paraformaldehyde were fixed for fifteen seconds in a microwave at 100% power, and dehydrated. Microwave energy was then used to polymerize the London Resin White (LR White) acrylic resin during the embedding process. Embedded specimens were then thin sectioned (90 nm) and treated with anti-tomato spotted wilt tospovirus (TSWV) antiserum followed by protein A-gold label, or antisera against a TSWV encoded nonstructural protein followed by goat anti-rabbit gold label. Using this technique, structural and nonstructural proteins of TSWV were readily detected and specifically labelled in cells of the insect vector, the western flower thrips, Frankliniella occidentalis (Pergande), and in infected cells of the plant species, Emilia sonchifolia L.

Animals↗

Management of severe partial hypodontia: case report.

Hypodontia is characterized by partial or total congenital missing of one or more teeth, on one or both dentitions. Heredity is the main etiological factor and the principal clinical features are reduction on number, size and form of teeth, and late eruption. Removable partial prosthesis, fixed prosthesis, overdentures and adhesive prosthesis are alternative treatments; and the indication is type dependent. The aim of this study was to describe the clinical case of an eleven-year-old child with eight missing permanent teeth of idiopathic etiology. The patient had facial and skeletal symmetry, normal development and was not related to any syndrome. Clinical characteristics: permanent teeth with good periodontal conditions (16, 12, 11, 21, 22, 26, 36, 31, 42, 46), primary teeth (53, 63, 64, 73, 83); overbite and microdontia on teeth 12 and 22. The treatment plan was done initially by documenting of the case for teeth analysis (study casting models, periapicals and panoramic x-rays, and photographs), and followed by the exodontics of teeth 73 and 83. A removable appliance in autocured acrylic resin, using teeth in acrylic for maintenance of functional space and occlusion was planned and carried out. An anterior track for vertical dimension gain was used because of his accentuated overbite. The patient will be monitored until the end of the craniofacial growth, when it will be again evaluated and forwarded for the final oral rehabilitation. Hypodontia diagnosis and management should be performed as early as possible not to interfere with the craniofacial development of the child.

Age Factors↗

Dynamic orificial resin adjustable nasal stents.

A technique is described for use of intranasal acrylic resin stents with finger springs and/or orthodontic jackscrew expanders for initiating and maintaining a desired amount of opening in the presence of scar tissue or grafts.

Acrylic Resins↗

Antigen detection on resin sections and methods for improving the immunogold labeling by manipulating the resin.

Considering the importance of immunolocalization of cellular substances combined with good ultrastructure and ease of use, this review is focused on the use of resin and the possibilities of manipulating the resin before and after embedding in order to improve the immunolabeling of resin sections for electron microscopy. The qualities of acrylic resins and conventional epoxy resin for immunoelectron microscopy are discussed. Acrylic sections are usually more suited for immunoelectron microscopy than conventional epoxy sections. Different etching procedures (sodium ethoxide or sodium metaperiodate) may be applied to conventional epoxy sections to enhance the yield of immunolabeling. Lately, a method which does not involve any kind of etching has been developed for enhancing the immunogold labeling of epoxy sections up to about 8 times. This method involves increased concentration of accelerator in the epoxy resin mixture when processing the tissue. The ultrastructural preservation of the tissue is important in immunoelectron microscopical procedures, and not only the intensity of the immunolabeling; in this respect no resin may compete with the widely used epoxy resins.

Acrylic Resins↗

Fracture toughness of composite and unfilled restorative resins.

Fracture toughness, critical strain energy release rate, and critical stress intensity factor were determined for experimental and commercial restorative resins. A composite resin had lower resistance to crack initiation than an unfilled acrylic resin. The data were consistent with surface failure observed in single-pass wear studies of these resins.

Acrylic Resins↗

A clinical survey of removable partial dentures. --Analysis of follow-up examinations over a sixteen-year period--.

In order to carry out the proper prosthetic treatment, it is necessary to select the method of treatment on the basis of accurate information concerning the prognosis of the prosthetic appliance. The oral structures are particularly proved to change when partial dentures are being used because the structures of the partial dentures are quite complex and they are easily broken. Therefore, in an attempt to analyze the changes that occur in the oral structures and partial dentures after insertion of the partial dentures, we conducted 3 series of follow-up examinations. The author sent out questionnaires and also conducted follow-up examinations of the patients. A summary of the major findings is as follows: 1) The percentage of those patients who came for their follow-up examinations, using metal based dentures, rose sharply over time. There were only 11.99% of the patients using the metal based dentures at the time the first study was conducted, but this rose to 58.13% at the time of the second study and 73.73% at the time of the third study. 2) The proportion of the patients who had anterior partial dentures declined over time from 9.36% at the time of the first study to 8.74% at the time of the second study and finally to 5.61% at the time of the third study. 3) The proportion of the partial dentures that had fractured was 23.15% at the time of the first study and 16.37% at the time of the second study and 16.67% at the time of the third study. 4) There was a striking difference in the fracture frequency of the acrylic resin based partial dentures and that of the metal based partial dentures. The denture bases of the acrylic resin-based partial dentures fractured about four times as often as those of the metal based partial dentures. 5) In all three studies it was found that about 60% of the caries occuring on the abutment tooth occurred on the edentulous proximal side. 6) Changes in the mucous membrane, such as inflammation or development of ulcers, had occurred in 48.86% of the cases at the time of the first study. This proportion declined to approximately 47% at the time of the second and finally to 43% at the time of the third study. 7) In examining the changes in the mobility of the abutment teeth, it was found that in all three studies approximately 20 to 30% of the abutment teeth demonstrated increased mobility, and about 10 to 20% showed decreased mobility while 55 to 65% showed no change.

Acrylic Resins↗

Resins for combined light and electron microscopy: a half century of development.

The last fifty years have seen enormous improvements in the way biological specimens are prepared for microscopy. The Fifties produced the essential groundwork upon which many of our current methodologies are based. Acrylic resin embedding was introduced in 1949, with subsequent publications seeking improvements to resin formulations, embedding protocols, and modes of polymerisation. Procedures for progressive lowering of temperature processing, cryosubstitution, freeze-drying and polymerisation by ultra-violet light at low temperatures, all had their genesis in this decade of great innovation. The Sixties marked the period when the acrylics were eclipsed by the more stable and reliable epoxy resins, and much of our present-day understanding of ultrastructure was elucidated. The Seventies carried on this work with advances in technical developments concerned mainly with freezing methodologies. The beginning of the Eighties saw a resurrection of the acrylic resins, with new formulations of these resins giving reliable and stable embeddings. The low temperature and freezing methodologies pioneered in the Fifties, backed up by recent improvements to low temperature technologies, were used to further our understanding of ultrastructure and breathe new life into the science of immunocytochemistry. The remainder of the Eighties and Nineties has seen the ever increasing application of these various microscopical techniques to a wide range of biological studies. The flexibility offered by the acrylic resins in choosing between different processing, embedding and polymerisation methods has provided the impetus for detailed studies to bring to the attention of microscopists the underlying trends governing specimen preparation. Therefore, looking forward to the new Millennium, this has allowed for a more reasoned choice in organising a strategy to deal with a variety of microscopical requirements and for planning an appropriate protocol.

Catalysis↗

Localized three-body wear of six types of composite resin veneering materials.

The wear resistance of six types of composite resin veneering materials was determined in vitro by use of a three-body wear-testing device. This investigation examined the wear characteristics of the veneering composite resins in heavy occlusal contact areas. After repeated cyclic loading, wear values were measured with a profilometer, and surface textures were evaluated with a scanning electron microscope. All of the composite resin veneering materials were significantly more wear resistant than unfilled acrylic resin; but the composite resin materials demonstrated rougher surfaces than unfilled resin. Three of the composite resins exhibited fractures in the contact areas.

Acrylic Resins↗