Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLATES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74Linked to original sources

Azocrosslinked poly(acrylic acid) for colonic delivery and adhesion specificity: in vitro degradation and preliminary ex vivo bioadhesion studies.

This study reports on the performance of a novel polymeric material that is capable of providing site specificity in active agent delivery and the development of mucoadhesive interactions. Azo-networks, based on an acrylic backbone crosslinked with 4,4'-divinylazobenzene, were subjected to in vitro degradation and mucoadhesion (before and after degradation) testing in order to model their performance in the gastrointestinal tract. Advanced surface characterisation techniques (SEM, AFM, FTIR microscopy) were used to examine the network morphology prior to, and after degradation. The data obtained from these studies indicate that there is an optimum crosslinking density to allow non-adhesive particles to reach the colon. Within the colonic environment, the azo network degrades to produce a structure capable of developing mucoadhesive interactions with the colonic mucosa.

Acrylic Resins↗

Azocross-linked poly(acrylic acid) for colonic delivery and adhesion specificity: synthesis and characterisation.

A new synthetic pathway to 4,4'-divinylazobenzene is presented together with a procedure for the copolymerisation of this compound with acrylic acid. The chemical structure of the synthesised series of copolymers is examined in the light of infrared spectroscopy results and nuclear magnetic resonance data. The thermal properties of the materials are assessed using a combination of thermal analysis techniques and their swelling behaviour is evaluated at physiologically relevant buffers designed to mimic the gastrointestinal environment.

Acrylic Resins↗

Preparation and in vitro release studies of ibuprofen-loaded films and microspheres made from graft copolymers of poly(L-lactic acid) on acrylic backbones.

The present article describes the preparation of films of various thickness and microspheres from new resorbable graft copolymers of polyacrylic (methyl methacrylate, MMA, or methyl acrylate, MA), or polyvinylic (vinyl pyrrolidone, VP) chains and poly(l-lactic acid) (PLLA) side blocks charged with 15-20% of ibuprofen (IBU) (a non-steroidic antiinflammatory agent). In the case of MMA-LLA and MA-LLA graft copolymers the release of IBU in buffered solution is modulated by the flexibility of the copolymer chains in a first step of one to two days and in a second step by the diffusive properties of the system as well as by the biodegradation of the polymers. The VP-PLLA graft copolymers are highly hydrophilic and the release of IBU is modulated by the diffusion of the drug through the swollen system. Specific interactions between the IBU molecules and the pyrrolidone rings also participate in the kinetic behaviour of the release process.

Acrylates↗

Drug release from poly(acrylic acid) grafted poly(vinylidene fluoride) membrane bags in the gastrointestinal tract in the rat and dog.

Stomach-specific drug delivery systems would be of value in treating diseases of the upper gastrointestinal tract. The present study measured in vitro and in vivo drug release from pH-sensitive membrane bags, constructed of poly(acrylic acid) grafted onto a poly(vinylidene fluoride) (PAA-PVDF) membrane, which might be suitable for stomach-specific drug delivery. The used model drugs were propranolol-HCl (1.0 mg) and FITC-dextran MW 4400 (1.0 mg). Drug release in vivo was studied by inserting membrane bags into the stomach and proximal duodenum of anesthetized rats and dogs. At 30 and 180 min, the bags were removed from the lumens and residual drug content was determined. The release of either propranolol or FITC-dextran were comparable in both stomach and duodenum, showing that in vivo drug release did not depend on environmental pH. In vitro results suggested that these results could be explained by interactions between PAA and the mucous layers of the stomach and duodenum.

Acrylic Resins↗

Acrylic acid: two-generation reproduction toxicity study in Wistar rats with continuous administration in the drinking water.

In a two-generation reproduction toxicity study, groups of 25 male and 25 female Wistar rats (for both F0 and F1 generations) received acrylic acid (AA) in the drinking water at concentrations of 0 (control), 500, 2500 and 5000 ppm for at least 70 days prior to mating, through mating, gestation, lactation and to weaning. The study continued through to weaning of the F2 offspring at 21 days of age. Achieved intakes of AA for the F0 and F1 parents during premating ranged from 46 (500 ppm) to 502 (5000 ppm) mg/kg/day. AA had no adverse effects on fertility and reproductive performance of the parent rats at doses up to 5000 ppm. General systemic toxicity was apparent with reduced body weights, food and water consumption in F0 parents at 5000 ppm and in F1 parents at 2500 and 5000 ppm; the only treatment-related pathological finding was a minimal hyperkeratosis of the limiting ridge of the forestomach with a minimal oedema of the submucosa of the glandular stomach in both parental generations at 5000 ppm. Dose-related signs of developmental toxicity were detected in F1 and F2 pups at 2500 and 5000 ppm in the form of retarded growth and some delay in the eye/auditory canal opening in F2 pups, but there was no evidence that AA had an adverse influence on pup morphology. Thus, the no-observed-adverse-effect level (NOAEL) is 5000 ppm for fertility and reproductive performance of the parents, 2500 ppm (F0 parents) or 500 ppm (F1 parents) for general systemic toxicity and 500 ppm for developmental toxicity.

Acrylates↗

Effect of the curing conditions on the properties of an acrylic denture base resin microwave-polymerised.

OBJECTIVES: The aim of this study is to evaluate the effect of the different conditions of curing on the residual monomer levels, hardness and impact strength of a microwave-polymerised acrylic resin. METHODS: The material was polymerised in a microwave oven in four different conditions of power and curing time. The kinetics of release of residual monomer in water was evaluated by spectrophotometric method up to 24 h. The hardness of the sample was determined by the Rockwell method and the impact strength tested by the Charpy method. The results were subjected to statistical analysis using ANOVA and Tukey's test for comparison. RESULTS: The levels of residual monomer were found dependent upon the curing conditions and they were correlated with the values of impact strength. Significant differences were observed in this property regarding the analysed conditions (p<0.001). CONCLUSIONS: From the appropriate selection of power and time of curing of the resin, it is possible to optimise the level of residual monomer and a low cytotoxicity keeping at the same time the best mechanical properties.

Acrylic Resins↗

Quantitative determination of BMS186716, a thiol compound, in dog plasma by high-performance liquid chromatography-positive ion electrospray mass spectrometry after formation of the methyl acrylate adduct.

As it is extremely unstable in blood, the thiol compound BMS186716 was stabilized by the addition of methyl acrylate (MA) to blood samples. The blood samples were then kept in ice for 10-15 min for completion of the Michael addition reaction to occur between the thiol group of BMS186716 and MA, after which the plasma was separated by centrifugation under refrigeration. For sample analysis, the standard and quality control samples were prepared by spiking blank plasma with the BMS186716-MA adduct. After addition of the internal standard, BMS 188035-MA, each sample was acidified with HCI and then extracted with methyl tert.-butyl ether. Each reconstituted extract was injected into a high-performance liquid chromatography-positive ion electrospray ionization mass spectrometric system. The electrospray condition was chosen to enhance the [M+NH4]+ signal at the expense of the [M+H]+ signal. Monitoring the [M+NH4]+ signal, a lower limit of quantitation of 2.5 ng/ml was achieved, with 0.5 ml plasma. We have thus shown that a sulfhydryl compound (BMS186716) in blood can successfully be stabilized by reacting it with MA and that the adduct produced is adequately stable in blood and plasma to allow the development of a rugged quantitative bioanalytical method.

Acrylates↗

The influence of vacuum mixing on methylmethacrylate liberation from acrylic cement powder.

Polymethylmethacrylate (PMMA) bone cement is a biomaterial used to anchor prostheses during joint replacement surgery. Residual methylmethacrylate monomer (MMA) may be related with the cytotoxic effect of PMMA. The aim of the present paper was to investigate the effect of two different cement mixing methods: hand stirring at atmospheric pressure and under partial vacuum (0.330 and 0.154 bar) on residual monomer liberation in phosphate buffer saline solution from acrylic cement powder. Residual MMA content was determined by high-performance liquid chromatography. Mathematical models were applied to experimental dissolution data revealing that monomer release was significantly reduced in bone cement powder obtained at 0.154 bar vacuum pressure compared to the other mixing conditions. The kinetic models applied are consistent with a simple diffusion mechanism of the monomer from the polymer matrix.

Acrylates↗

Influence of ionic strength on drug adsorption onto and release from a poly(acrylic acid) grafted poly(vinylidene fluoride) membrane.

Ion exchange resins have several applications in pharmacy for controlled or sustained release of drugs. In the present study, effects of the ionic strengths of adsorption medium and dissolution medium on drug adsorption onto and release from a acrylic acid grafted poly(vinylidene fluoride) (PAA-PVDF) were studied. Despite their porosity, PAA-PVDF membranes act reasonable well as cation exchange membranes. It was observed, that ionic strength of adsorption medium, degree of grafting and concentration of propranolol-HCl in adsorption medium affect propranolol-HCl adsorption onto the membrane. The fluxes of smaller molecules (MW < 500) across the membrane decreased with ionic strength of buffer solution, whereas the fluxes of the large molecules (FITC-dextran, MW 4400) increased with ionic strength. Release rate of adsorbed propranolol-HCl from the membrane into phosphate buffer was greatly affected by ionic strength of adsorption medium. These results can be explained by a cation exchange process between membrane and cations present in the buffer solution and swelling behavior of the grafted PAA chains.

Acrylates↗

Investigations into the structure and composition of beta-cyclodextrin/poly(acrylic acid) microspheres.

Microspheres composed of the hydrophilic polymer poly(acrylic acid) (PAA), with and without beta-cyclodextrin (beta-CD), were prepared by a water-in-oil (w/o) solvent evaporation technique. Microspheres were characterised for particle size, beta-CD and residual oil content. The type of matrix formed during microsphere synthesis was investigated by solid state carbon 13C NMR, in vitro release of beta-CD and swelling measurements. A high encapsulation efficiency of the beta-CD was observed (?90%). The in vitro release of beta-CD in water over 24 h was initially rapid ( approximately 70% in 3 h) with no further loss thereafter, suggesting potential covalent binding of the residual beta-CD. NMR indicated that in the presence of beta-CD, two concomitant chemical processes occur during microsphere synthesis: (i) esterification of the hydroxyl group(s) of the beta-CD with the carboxylic acid groups of the PAA; and (ii) the formation of intra-/inter-polymer acid anhydrides.

Acrylic Resins↗

Simultaneous determination of tiopronin and its metabolites in rat blood by LC-ESI-MS-MS using methyl acrylate for stabilization of thiol group.

A sensitive and reproducible HPLC-electrospray tandem mass spectrometric method has been developed for the analysis of tiopronin (TP) and its metabolites, 2-mercaptopropionic acid (2-mpa) and S-methylated TP (SA13), in rat blood using methyl acrylate (MA) for the stabilization of a thiol group. The thiol groups of TP and 2-mpa in rat blood were immediately derivatized by the addition of MA-acetonitrile solution in 0.1 M Tris HCl (pH 9.1). The purification of the derivatives was accomplished by a simple liquid-liquid extraction procedure involving protein precipitation step. The analysis was performed on a Zorbax SB-C18 analytical column by a gradient elution with methanol-0.05 M acetic acid (15:85 and 7:3, v/v). Negative ion electrospray ionization with selected reaction monitoring was employed for the detection of analytes. Linearity of calibration was observed over the range of 0.5-1000 ng/ml for TP and 2-mpa, and 2-1000 ng/ml for SA13. The intra- and inter-assay variability for all analytes at the limit of quantitation (LOQ) level ranged from 5.47 to 16.75% and 4.95 to 7.23%, respectively. The LOQs estimated for TP, 2-mpa and SA13 were 0.5, 0.5 and 2 ng/ml, respectively. This assay method was successively applied to a pharmacokinetics study after an oral administration of TP (10 mg/kg) to rats.

Acrylates↗

Visual complaints associated with the AcrySof acrylic intraocular lens(1).

PURPOSE: To describe the visual complaints of a series of patients implanted with the AcrySof(R) (Alcon Surgical) acrylic intraocular lens (IOL) that resolved with IOL exchange. SETTING: Jules Stein Eye Institute, Los Angeles, California, and John A. Moran Eye Center, Salt Lake City, Utah, USA. METHODS: This was a retrospective review of patients who had AcrySof IOL exchange from January 1997 to December 1998. RESULTS: Eight patients (9 eyes) with bothersome visual symptoms following AcrySof IOL implantation were identified. Problems included glare, halos around point light sources, and peripheral arcs of light, often worse at night. In each case, the IOL was well-centered in the capsular bag and there was no significant posterior capsule opacification. Six patients (7 eyes) had the MA30BA model with a 5.5 mm optic, and 2 patients (2 eyes) had the MA60BM model with a 6.0 mm optic. No extralenticular reasons for the patients' complaints could be identified. Exchanging the AcrySof IOLs with silicone or poly(methyl methacrylate) IOLs alleviated most symptoms. In 5 of 8 patients, dysphotopsias resolved completely. CONCLUSIONS: A small number of patients implanted with AcrySof IOLs have specific complaints of glare, halos, and peripheral arcs of light. Optical considerations that may help explain these symptoms include the high refractive index of the IOL material and the truncated design of the optic. Patients who are highly observant and those with large pupils may be particularly symptomatic. Intraocular lens exchange may be necessary in some cases.

Acrylates↗

Posterior capsule opacification and lens epithelial cell layer formation: Hydroview hydrogel versus AcrySof acrylic intraocular lenses.

PURPOSE: To quantitatively compare the incidence of visually significant posterior capsule opacification (PCO) and lens epithelial cell (LEC) layer formation on the anterior surface of Hydroview hydrogel and AcrySof acrylic foldable intraocular lenses (IOLs) after implantation. SETTING: Single-surgeon ophthalmology practice, Orange Base Hospital, and Dudley Private Hospital, Orange, New South Wales, Australia. METHODS: This retrospective study comprised 166 eyes of 150 patients (after exclusions) who had cataract extraction and insertion of a foldable IOL in the capsular bag by a single surgeon using a standardized phacoemulsification technique from December 1997 to September 1998. The mean follow-up was 13.1 months (range 6.0 to 23.6 months). The eyes were divided into 2 groups based on the type of IOL implanted: Storz Hydroview H60M (81 eyes) or Alcon AcrySof MA30BA (85 eyes). A neodymium:YAG posterior capsule laser capsulotomy (PC YAG) was performed for an objective decrease in Snellen best corrected visual acuity (BCVA) of more than 1 line, significant visual symptoms, or both. This was used as a measure of visually significant PCO. An Nd:YAG anterior surface clearance (ASC YAG) was done for LEC layer formation anterior to the IOL to better visualize or facilitate treatment of PCO. The rates of PC YAG and ASC YAG after Hydroview and AcrySof IOL implantation were statistically compared. RESULTS: Forty-five eyes (55.6%) in the Hydroview IOL group and 3 eyes (3.5%) in the AcrySof IOL group required a PC YAG; the risk difference was 52.0% (P <.001). An ASC YAG was required in 27 eyes (33.3%) in the Hydroview group and 1 eye (1.2%) in the AcrySof group; the risk difference was 32.2% (P <.001). Survival analysis demonstrated that the only independent predictor of the incidence of PC YAG and ASC YAG over time was IOL type, with the Hydroview IOL group having a statistically significantly higher incidence of both procedures. CONCLUSION: There was a greater incidence of visually significant PCO and LEC layer formation on the anterior surface of Hydroview IOLs than of AcrySof IOLs.

Acrylic Resins↗

Patient satisfaction after uneventful cataract surgery with implantation of a silicone or acrylic foldable intraocular lens. Comparative study.

PURPOSE: To compare patient satisfaction with vision 12 months after implantation of a silicone or acrylic foldable intraocular lens (IOL). SETTING: John A. Moran Eye Center, University of Utah Medical Center, Salt Lake City, Utah, USA. METHODS: Selection criteria included patients who had uneventful cataract extraction by phacoemulsification with a temporal clear corneal incision or superior scleral tunnel incision, a curvilinear capsulorhexis, and in-the-bag IOL placement. One hundred sixty-two patients surveyed had a mean follow-up of approximately 15 months (range 12 to 18 months). Patients were divided into 3 groups of 54 each based on IOL type: AMO SI-30/40, Alcon MA30BA, and Alcon MA60BA. All patients were surveyed over the telephone using a standardized questionnaire protocol. They were questioned about their perception of vision with best optical correction in relation to visual blurring symptoms, glare symptoms, night vision, near vision, and overall vision. RESULTS: There were no significant differences in patient satisfaction among the 3 IOL groups in visual blurring or night vision. Patients in the SI-30/40 and MA60BA groups reported significantly higher satisfaction with glare symptoms, near vision, and overall satisfaction than patients in the MA30BA group. CONCLUSION: The SI-30/SI-40 and the MA60BA IOLs received significantly higher patient satisfaction scores than the MA30BA IOL in glare symptoms, near vision, and overall satisfaction.

Acrylic Resins↗

Suture fixation of a foldable acrylic intraocular lens for ectopia lentis.

A 5-year-old boy with severe ectopia lentis had bilateral lensectomy and suture fixation of a foldable acrylic intraocular lens (IOL) through a 3.0 mm clear corneal incision. Sodium hyaluronate (Healon GV) enhanced stability of the crystalline lens during aspiration and maintenance of the anterior chamber during passage of the needles through the ciliary sulcus. The haptic design of the single-piece AcrySof (Alcon) IOL permitted secure fixation of the suture to the haptic. The patient experienced rapid visual rehabilitation, achieving an uncorrected visual acuity of 20/40 in both eyes.

Acrylic Resins↗

Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly(methyl methacrylate) lenses.

PURPOSE: To evaluate how and how fast a capsular bend is created clinically at the optic edge of an intraocular lens (IOL) after cataract surgery. SETTING: Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. METHODS: Capsular bend formation was observed by slitlamp after maximum pupil dilation in 45 eyes of 45 patients with senile cataract. Fifteen eyes each received an AcrySof MA60BM acrylic (Alcon), PhacoFlex II SI-40NB silicone (Allergan), or UV26T poly(methyl methacrylate) (PMMA) (Menicon) IOL. Patients were evaluated prospectively at 1 day and 1, 2, and 4 weeks and retrospectively (15 eyes per IOL) 1 year after cataract surgery. A capsular bend index was developed to document and categorize the capsular bend formation process at the IOL optic edge. RESULTS: The anterior and posterior capsules adhered, with the latter attracted to the former. The adhesion always progressed from the periphery to the optic edge so that the posterior capsule eventually wrapped around the posterior optic edge, although not fully circumferentially in all cases. The process took place in 4 stages. Capsular bend formation was complete 1 month after surgery with the foldable IOLs (AcrySof, PhacoFlex II) but was significantly delayed with the PMMA IOL. After 1 year, the capsular wrapping was firm and fully circumferential at the optic edge with all IOL types in all cases. CONCLUSIONS: Capsular bend formation progressed in the same fashion but at significantly different speeds among the IOLs, suggesting that the process depends on IOL material and design. Fast, early capsular bend formation may be 1 reason AcrySof and PhacoFlex II IOLs prevent PCO statistically better than PMMA IOLs. The results indicate that PCO is prevented by the sharp capsular bend created by sharp optic edges and by quick bend formation.

Acrylic Resins↗

Complete anterior capsule contraction after phacoemulsification with acrylic intraocular lens and endocapsular ring implantation.

A 69-year-old man with pseudoexfoliation syndrome and bilateral cataract had phacoemulsification with continuous curvilinear capsulorhexis and implantation of a morcher endocapsular ring and AcrySof acrylic intraocular lens (IOL) (Alcon). Two months later, the patient had vision loss in the left eye with a visual acuity of 20/500. He presented with anterior capsule fibrosis in both eyes, with complete occlusion of the capsule opening in the left eye and mild occlusion in the right eye. After a neodymium:YAG laser anterior capsulotomy in the left eye, visual acuity was 20/20. This case shows that endocapsular ring implantation does not prevent anterior capsule contraction syndrome but can prevent IOL decentration.

Acrylic Resins↗

Visual discomfort after acrylic intraocular lens implantation.

A 64-year-old man had phacoemulsification in both eyes. In January 1998, an Allergan SI-30NB silicone intraocular lens (IOL) with a 6.0 mm optic was implanted in the right eye. In April, an Alcon AcrySof MA60BN acrylic IOL with a 6.0 mm optic was implanted in the left eye. The following October, the patient experienced visual discomfort in the left eye. Two superior radial minikeratotomies were performed. The patient continued to have visual discomfort and the next month, a topographic ablation was performed in the same eye. In January 2000, the left IOL was replaced with a 5.5 mm Allergan SI-55NB silicone IOL. Visual impairment resolved 1 day after surgery.

Acrylic Resins↗