Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “sample preparation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Formation of an artifact of diclofenac during acidic extraction of environmental water samples.

Solid-phase extraction at an acidic pH is used as a common sample preparation method for analyzing residues of the analgesic drug diclofenac (2-[(2,6-dichlorophenyl)amino] benzeneacetic acid) in environmental water samples. This paper describes the matrix-dependent formation of an artifact of diclofenac during sample preparation resulting in an up to 40% underestimation of diclofenac concentrations especially in matrix-prone samples such as sewage effluents or surface water. The artifact most likely being formed during acidification of the sample was unequivocally identified as 1-(2,6-dichlorophenyl)indolin-2-one by capillary gas chromatography-mass spectrometry. To avoid an underestimation of the analytical results quantification of both diclofenac and its artifact is recommended.

Anti-Inflammatory Agents, Non-Steroidal↗

Xq27-28 deletions in prostate carcinoma.

Linkage studies have implicated a prostate cancer susceptibility locus at Xq27-28 (termed HPCX), estimated to be responsible for approximately 16% of hereditary prostate cancer cases. To date, this region has not been investigated in sporadic disease. In this study, we examined tumor DNA samples prepared from patients with sporadic prostate cancer, prostate cancer cell lines, and prostate cancer xenografts for evidence of genomic alterations within the Xq27-28 region. To facilitate the detection of nullizygosity, we examined a unique series of highly tumor-enriched DNA samples prepared from men with multi-sampled metastatic prostate cancer, as well as a series of prostate cancer xenografts and cell lines. PCR amplification of carcinoma and normal DNA templates was performed for 11 loci spanning an Xq27-28 interval of approximately 16 cM. Among 19 patients studied, somatic deletions in this region were found in two cases. Within these two cases, each independent metastatic tumor sample available from an individual (n = 4 sites and 8 sites, respectively) showed the same reduction to nullizygosity, suggesting a pre-metastatic origin for the deletion events in both. Mapping of the deletion boundaries with eight additional sets of markers indicated that both deletions had breakpoints within an approximately 500- to 800-kb interval containing FMR1; however, the deletions were non-overlapping. The lack of a common region of deletion suggests one of three possibilities: (1) that these two deletions are unrelated, (2) that the deletions affect the opposite ends of an as yet unknown gene, or (3) that each deletion has inactivated a single copy of an unknown gene arranged in cis in the region of interest. These data clearly indicate that deletions do occur within the HPCX locus in a subset of sporadic prostate cancers and therefore raises the possibility that the gene at this locus may prove to play a role in sporadic disease.

Animals↗

Glutathione stability in whole blood: effects of various deproteinizing acids.

High-performance liquid chromatography separation of reduced and oxidized glutathione (GSH and GSSG) in biologic samples using electrochemical detection offers the convenience of both simultaneous quantitation and simple sample preparation. Rapid acidification is required to prevent GSH autooxidation, GSH and GSSG degradation, and precipitate proteins that interfere with analysis. Currently, little consistency exists in the literature regarding acid selection or the feasibility of sample storage before analysis. The purpose of this work was to examine the effects of perchloric (PCA), trichloroacetic (TCA), metaphosphoric (MPA), and 5-sulfosalicylic (SSA) acids on the short-term stability of GSH and GSSG measurements in whole blood. Samples were collected from adult volunteers and treated with multiple concentrations of each acid. The samples were analyzed immediately and aliquots were stored at -80 degrees C for up to 28 days. The suitability of each acid was assessed by percentage change of GSH and GSSG from baseline, efficiency of protein removal, and alteration of chromatogram characteristics. In general, increasing the acid concentration improved sample stability. Nevertheless, SSA did not achieve acceptable sample stability at any concentration tested. MPA was found to leave substantial amounts of protein in the samples, and TCA may interfere with the peaks of interest. Based on these results, a final concentration of 15% PCA is suggested for analysis of glutathione in whole blood. Although immediate sample preparation is preferred, 15% PCA can maintain sample integrity for 4 weeks after storage at -80 degrees C.

Adult↗

New methods of track membrane treatment in the preparation of samples for further observation with scanning electron microscopy.

Track membranes are porous systems consisting of a polymer foil with thin channels (i.e. pores) piercing it from surface to surface. The creation of non-cylindrical pores in a track membrane is important for the optimization of membrane characteristics, i.e. the highest productivity at the required selectivity. A new method of cleavage preparation (the irradiation of track membrane samples with accelerated electrons) for the observation of channel shapes directly in the membrane cross-sections is presented. Diagrams showing the tensile and burst strengths as a function of the irradiation dose, and images of surfaces and cleavages of track membrane samples are presented in this work. The changes in the pore sizes and shapes along the channel were clearly seen. These results can be used for the optimization of track membrane production.

Journal Article↗

A sensitive method for the determination of uranium in biological samples utilizing kinetic phosphorescence analysis (KPA).

Kinetic phosphorescence analysis is a technique that provides rapid, precise and accurate determination of uranium concentration in aqueous solutions. This technique utilizes a laser source to excite an aqueous solution of uranium, and measures the emission luminescence intensity over time to determine the luminescence decay profile. The lifetime of the luminescence decay profile and the linearity of the log luminescence intensity versus time profile are indications of the specificity of the technique for uranium determination. The luminescence intensity at the onset of decay (the initial luminescence intensity), which is the luminescence intensity at time zero after termination of the laser pulse used for excitation, is proportional to the uranium concentration in the sample. Calibration standards of known uranium concentrations are used to construct the calibration curve between the initial luminescence intensity and uranium concentration. This calibration curve is used to determine the uranium concentration of unknown samples from their initial luminescence intensity. We developed the sample preparation method that allows the determination of uranium concentrations in urine, plasma, kidney, liver, bone spleen and soft tissue samples. Tissue samples are subjected to dry-ashing in a muffle furnace at 600 degrees C and wet-ashing with concentrated nitric acid and hydrogen peroxide twice to destroy the organic component in the sample that may interfere with uranium determination by KPA. Samples are then solubilized in 0.82 M nitric acid prior to analysis by KPA. The assay calibration curves are linear and cover the range of uranium concentrations between 0.05 micrograms l-1 and 1000 micrograms l-1 (0.05-1000 ppb). The developed sample preparation procedures coupled with the KPA technique provide a specific, sensitive, precise and accurate method for the determination of uranium concentration in tissue samples. This method was used to quantify uranium in different tissue samples obtained over a period of 90 days following a single intraperitoneal uranium dose of 0.1 mg kg-1 in rats.

Animals↗

Phosphate removal from aqueous solutions using raw and activated red mud and fly ash.

The effect of acidification and heat treatment of raw red mud (RM) and fly ash (FA) on the sorption of phosphate was studied in parallel experiments. The result shows that a higher efficiency of phosphate removal was acquired by the activated samples than by the raw ones. The sample prepared by using the RM stirred with 0.25 M HCl for 2h (RM0.25), as well as another sample prepared by heating the RM at 700 degrees C for 2h (RM700), registered the maximum removal of phosphate (99% removal of phosphate). This occurred when they were used in the phosphate sorption studies conducted at pH 7.0 and 25 degrees C with the initial PO(4)(3-) concentration of 155 mg P/l. The FA samples treated in the same way described above can achieve 7.0 and 8.2 mg P/l phosphate removal for FA0.25 and FA700 respectively, corresponding to 45.2% and 52.9% removal. The activated materials performed higher phosphate removal over broader pH range compared with the raw ones. The influences of various factors, such as initial pH and initial phosphate concentration on the sorption capacity were also studied in batch equilibration technique. Solution pH significantly influenced the sorption. Each sample achieved the maximal removal of phosphate at pH 7.0. The amount of phosphate removal increased with the solute concentration. The Freundlich and Langmuir models were used to simulate the sorption equilibrium. The results indicate that the Langmuir model has a better correlation with the experimental data than the Freundlich model.

Adsorption↗

High spatial resolution imaging of bone mineral using computed microtomography. Comparison with microradiography and undecalcified histologic sections.

RATIONALE AND OBJECTIVES: The application of various high-resolution (< 100 microns) imaging techniques for in vitro bone mineral analysis is explored. METHODS: The techniques of contact microradiography and microtomography, using the x-ray spectrum filtered out of synchrotron radiation (SR) and conventional staining techniques, are compared to each other by presenting a variety of different samples. The relationship between radiation exposure and spatial resolution micro-computed tomography (CT) images of a finger bone is explored. The relevant properties of SR are explained. RESULTS: In CT images, a spatial resolution of 100 microns was obtained. New bone mineral induced by mechanical periosteal irritation in a rabbit tibia was quantified. In one case a microradiogram and a microtomogram of the same slice were taken for comparison. Histologic sections and microradiograms taken from a specimen of a human femur for comparison are presented. CONCLUSIONS: Microradiography and staining techniques require rather sophisticated sample preparation; quantitative image analysis is more difficult as the resulting image must be digitized. The CT technique requires almost no sample preparation and allows for accurate bone mineral quantification. However, CT images with a resolution of several microns limit the sample size to a few mm. Micro-CT and microradiography can be performed with conventional x-ray sources, but the use of SR is of particular interest in high resolution imaging, because its white spectrum allows for optimum x-ray energy selection and its high intensity for short scan times.

Absorptiometry, Photon↗

Determination of depleted uranium in environmental samples by gamma-spectroscopic techniques.

The military use of depleted uranium initiated the need for an efficient and reliable method to detect and quantify DU contamination in environmental samples. This paper presents such a method, based on the gamma spectroscopic determination of 238U and 235U. The main advantage of this method is that it allows for a direct determination of the U isotope ratio, while requiring little sample preparation and being significantly less labor intensive than methods requiring radiochemical treatment. Furthermore, the fact that the sample preparation is not destructive greatly simplifies control of the quality of measurements. Low energy photons are utilized, using Ge detectors efficient in the low energy region and applying appropriate corrections for self-absorption. Uranium-235 in particular is determined directly from its 185.72 keV photons, after analyzing the 235U-226Ra multiplet. The method presented is applied to soil samples originating from two different target sites, in Southern Yugoslavia and Montenegro. The analysis results are discussed in relation to the natural radioactivity content of the soil at the sampling sites. A mapping algorithm is applied to examine the spatial variability of the DU contamination.

Algorithms↗

European interlaboratory comparison of breath 13CO2 analysis.

The BIOMED I programme Stable Isotopes in Gastroenterology and Nutrition (SIGN) has focused upon evaluation and standardisation of stable isotope breath tests using 13C labelled substrates. The programme dealt with comparison of 13C substrates, test meals, test conditions, analysis techniques, and calculation procedures. Analytical techniques applied for 13CO2 analysis were evaluated by taking an inventory of instrumentation, calibration protocols, and analysis procedures. Two ring tests were initiated measuring 13C abundances of carbonate materials. Evaluating the data it was found that seven different models of isotope ratio mass spectrometers (IRMS) were used by the participants applying both the dual inlet system and the continuous flow configuration. Eight different brands of certified 13C reference materials were used with a 13C abundance varying from delta 13CPDB -37.2 to +2.0/1000. CO2 was liberated from certified material by three techniques and different working standards were used varying from -47.4 to +0.4/1000 in their delta 13CPDB value. The standard deviations (SDs) found for all measurements by all participants were 0.25/1000 and 0.50/1000 for two carbonates used in the ring tests. The individual variation for the single participants varied from 0.02 /1000 (dual inlet system) to 0.14/1000 (continuous flow system). The measurement of the difference between two carbonates showed a SD of 0.33/1000 calculated for all participants. Internal precision of IRMS as indicated by the specifications of the different instrument suppliers is < 0.3/1000 for continuous flow systems. In this respect it can be concluded that all participants are working well within the instrument specifications even including sample preparation. Increased overall interlaboratory variation is therefore likely to be due to non-instrumental conditions. It is possible that consistent differences in sample handling leading to isotope fractionation are the causes for interlaboratory variation. Breath analysis does not require sample preparation. As such, interlaboratory variation will be less than observed for the carbonate samples and within the range indicated as internal precision for continuous flow instruments. From this it is concluded that pure analytical interlaboratory variation is acceptable despite the many differences in instrumentation and analytical protocols. Coordinated metabolic studies appear possible, in which different European laboratories perform 13CO2 analysis. Evaluation of compatibility of the analytical systems remains advisable, however.

Breath Tests↗

The detection of nitrated tyrosine in neuropeptides: a MALDI matrix-dependent response.

Neuropeptides are a diverse class of signaling molecules that typically have one or more posttranslational modifications. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is an effective tool for identification and characterization of neuropeptides from samples as small as individual neurons. However, the detection of one particular posttranslational modification-nitrotyrosine-has been problematic because of the lability of the nitro group of nitrotyrosine under MALDI-MS conditions. The detection of nitrated tyrosine in peptide standards was dependent on the MALDI matrix used for the analysis. Specifically, sinapinic acid was the optimum matrix tested to observe this modification while it was not consistently detected with matrices such as 2,5-dihydroxybenzoic acid. Using the optimized procedures, several identified nitric-oxide-synthase positive neurons from Lymnaea stagnalis were tested to determine if the neuropeptides present were nitrated. In all cases, the nitrated form of the neuropeptide was not observed. The dependence on the sample-preparation procedures of observing this particular chemical modification demonstrates the need for careful selection of sample-preparation methods with MALDI or the use of other ionization methods.

Amino Acid Sequence↗

High-performance liquid chromatographic method for the simultaneous determination of the camptothecin derivative irinotecan hydrochloride, CPT-11, and its metabolites SN-38 and SN-38 glucuronide in rat plasma with a fully automated on-line solid-phase extraction system, PROSPEKT.

We established a high-performance liquid chromatography (HPLC) method for the simultaneous determination of the camptothecin (CPT) derivative, irinotecan hydrochloride (CPT-11) and its metabolites, 7-ethyl-10-hydroxycamptothecin (SN-38) and SN-38 glucuronide (SN-38G) in rat plasma with a fully automated on-line solid-phase extraction system, PROSPEKT. Plasma samples were pretreated with 0.146 M H3PO4 to inactivate carboxylesterase and beta-glucuronidase in rat plasma, and added with the internal standard solution (0.146 M H3PO4 containing 1 microgram/ml CPT) and then analyzed. The method was validated for CPT-11 (5 to 25,000 ng/ml), SN-38 (5 to 2500 ng/ml) and SN-38G (2.5 to 500 ng/ml). This method enabled the determination of many samples within a relatively short time with easy sample preparation. It also had four advantages compared with conventional determination methods, i.e. automation of a complicated sample preparation, time-saving by the simultaneous determination of three compounds, the direct determination of SN-38G, and the small amount of plasma required for the determination.

Animals↗

A simplified method for large scale quantification of transcriptional activity and its use in studies of steroids and steroid receptors.

Chloramphenicol acetyltransferase (CAT) is widely used as a reporter to determine the transcriptional specificity of promoters and for the quantification of transcriptional activity of transcription factors such as nuclear receptors. However, large-scale quantification of CAT activity in transfected mammalian cells is still heavily labor-intensive, time-consuming and expensive. Here, we describe a simplified method that combined using multiwell tissue culture plates in transfection and sample preparation and a modified single step method for quantitatively assaying CAT activity. By using multiwell plates, the tedious sample preparation procedure was dramatically simplified. The CAT assay is performed by mixing cell lysate, chloramphenicol, 3H-acetyl co-enzyme A and non-aqueous scintillation fluid in scintillation vials, followed by automatically continuously counting samples two or three cycles at fixed time intervals. The catalytic reaction and determination of CAT activity are carried out in the vials simultaneously. This simplified protocol is faster, less expensive and more accurate than other CAT assay procedures and the results can be normalized easily. The utility of the assay is demonstrated by the analysis of the transcriptional activity of the glucocorticoid and androgen receptors cotransfected into cells with a CAT reporter.

Animals↗

Analytical microextraction: current status and future trends.

Analytical microextractions, defined as nonexhaustive sample preparation with a very small volume of extracting phase (microliter range or smaller) relative to the sample volume, represent an important development in the field of analytical chemistry. Analytes are extracted by a small volume of a solid or semi-solid polymeric material, as in solid-phase microextraction (SPME), or alternatively by a small volume of a liquid, as in liquid-phase microextraction (LPME). This paper gives an overview of the SPME and LPME techniques and discusses future trends. This includes a discussion of the different extraction formats available, commercial equipment, method transfer from traditional sample preparation methods to microextraction, and performance as well as robustness for the latter type of systems. In addition, the paper contains a unified approach to the understanding of extraction thermodynamics and kinetics applicable to both SPME and LPME.

Chemical Fractionation↗

Transcutaneous photodynamic therapy alters the development of an adoptively transferred form of murine experimental autoimmune encephalomyelitis.

Transcutaneous photodynamic therapy (PDT), utilizing benzoporphyrin derivative monoacid ring A (BPD, verteporfin) and whole-body light exposure, was assessed for its capacity to modify the course of adoptively transferred experimental autoimmune encephalomyelitis (EAE) in PL mice. Using a novel cell culture technique to facilitate the induction of this neurodegenerative condition, disease signs commenced 3-4 weeks after the transfer of myelin basic protein (MBP)-reactive lymph node or spleen cells to naive syngeneic recipients. Mice administered MBP-sensitized lymph node cells preincubated with BPD followed by whole-body 690 nm light irradiation (15 J/cm2) did not display symptoms of EAE. Although almost all animals given MBP-sensitized spleen cells developed EAE, mice given BPD (1 mg/kg) and the light treatment 24, 48 or 120 h after spleen cell transfer exhibited significantly less severe disease symptoms than control animals. Mice given the photodynamic treatment 24 h after spleen cell transfer also exhibited a significantly later disease onset than the control animals. Treatment of mice with PDT 24 h prior to spleen cell transfer did not influence subsequent disease severity but modestly delayed its onset. In the absence of directed light, BPD did not influence the development of EAE. Spinal cord tissues were evaluated for the presence of T cell receptor (TCR) V alpha 4 mRNA transcripts that specifically encode for the TCR alpha-chain of MBP-reactive T cells of PL mice. Using the polymerase chain reaction, V alpha 4 TCR mRNA transcripts were present in spinal cord samples prepared from almost all control mice but in only about one-half of spinal cord samples prepared from mice treated with PDT 24 h after spleen cell transfer. These observations indicated that PDT had limited the expansion of MBP-specific V alpha 4+ T cells within the central nervous system. Transcutaneous PDT represents a new technique with which to approach the treatment of autoimmune disease.

Animals↗

Measurement of plasma-derived substance P: biological, methodological, and statistical considerations.

The undecapeptide substance P (SP) is a member of the tachykinin family of neurotransmitters, which has a pivotal role in the regulation of inflammatory and immune responses. One of the major barriers to the study of the in vivo role of SP in a number of immune disorders is the accurate measurement of SP in fluids. This is reflected in the variability of reported SP levels in serum and plasma of humans in both healthy and diseased states. This study was initiated in order to identify sources of variability by the comparative evaluation of the influences of sample preparation and analytical detection methods on the measurement of SP in plasma. The results indicate that sample preparation (peptide extraction versus no extraction) and the choice of analytical method for SP quantitation may yield significantly different values and may contribute to the variability in SP values reported in the literature. These results further emphasize the need for careful consideration in the selection of methods for SP quantitation, as well as caution in the interpretation and comparison of data reported in the literature.

Animals↗

Quality assurance in the determination of metals in clinical chemistry and toxicology: the METOS project. Metalli Tossici.

National external quality assessment schemes (EQAS) for the determination of trace elements in blood (Al, Cd, Cu, Pb, Zn) have been promoted in Italy since 1983. They were organized by a working group of the Istituto Superiore di Sanità and known as "METOS (Metalli Tossici, toxic metals) project". The organization of the schemes included the preparation of suitable control materials by the promoting centre and the elaboration of valuable strategies of sample distribution, treatment of data and evaluation of results, that could be applied even to a small number of participants. The procedures used and the results obtained in ten years of activity of the METOS project are reported. Within the framework of the programme some information has been obtained, confirming the validity of the procedures used for sample preparation, sample distribution and evaluation of laboratories performance.

Chemistry, Clinical↗

Immunomagnetic separation of Salmonella from foods and their detection using immunomagnetic particle (IMP)-ELISA.

An immunomagnetic particle based ELISA (IMP-ELISA) for the detection of Salmonella from foods has been developed using Dynabeads anti-Salmonella (Dynal, Oslo, Norway). Appropriate sample preparation protocols to allow rapid detection of Salmonella serovariants in processed (powdered egg products) and non-processed (raw chicken) samples have been established. Pre-enriched broths of heat processed samples likely to harbour only low levels of competitive enteric flora, were boiled and used directly for IMP-ELISA. For non-heat processed or raw samples likely to contain higher numbers of such competing organisms, live Salmonella cells were first isolated by immunomagnetic separation (IMS) from standard pre-enrichment broths, and then post-selectively enriched for a short time in M-broth followed by boiling before IMP-ELISA. The total assay time including sample preparation was under 26 h for both types of procedure, with a lower detection limit of 10(5) Salmonella cells/ml of sample. In an evaluation of naturally contaminated poultry samples, all 45 of 48 samples previously shown to contain salmonellae in a comparison of ISO, IMS-Plating, Salmonella-Tek ELISA (Organon Teknika, Inc. Durham, NC) and a modification of the latter based on IMS, were identified as positive. None of the other methods gave positives for all 45.

Animals↗

Search on ruggedness of fast gas chromatography-mass spectrometry in pesticide residues analysis.

In this study, suitability of fast gas chromatography-mass spectrometry (GC-MS) on a narrow-bore column with a programmed temperature vaporizer for the analysis of pesticide residues in non-fatty food was evaluated. The main objectives were ruggedness and stability of chromatographic system with regards to co-extractives injected. The chromatographic matrix induced response enhancement was found to be strongly dependent on the concentration of residues and is reaching up to 700% compared to the pesticides solutions in a neat solvent. However, the responses of pesticides in matrix-matched standards at different concentration levels do not significantly change during 130 injections. Response enhancement/or decrease is influenced by the sample preparation technique. External calibration with matrix-matched calibration standards should, therefore, provide results with good precision also at the concentration level of 0.005 mg kg(-1). Special attention is given to the performance of the chromatographic column and retention gap with regards to peak widths, peak tailing and different sample preparation methods. During approximately 460 matrix sample injections, the performance of the analytical column was acceptable. GC-MS set-up with 0.15 mm i.d. column can be successfully utilized for the pesticide residues analysis.

Food Analysis↗