Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data.

A physiological artifact reduction method based on extracting respiratory motion and cardiac pulsation directly from functional MR data is described. In fast low angle shot (FLASH), respiratory cycles are derived utilizing the phase of the center of a navigator echo, in echo-planar imaging (EPI) from the phase of the center k-space point. Cardiac cycles are determined from projections obtained from the navigator echo (FLASH) and the center k-space line (EPI). Because direct extraction of physiological parameters eliminates the need for external monitoring, the method can be more readily implemented. Experimental results illustrate that the technique provides effective compensation for physiology-related signal fluctuations in functional MRI and performs as well as the retrospective technique using external physiological monitoring.

Artifacts↗

Artifact reduction in EPI with phase-encoded reference scan.

Echo-planar imaging is becoming widely used for various applications. However, because of inherent limitations, images obtained with EPI are often degraded by artifacts arising from the inconsistency between the odd and even echoes in the acquired data. Several correction techniques, including those based on reference measurement, have been previously reported. In this paper, a correction method based on phase-encoded reference measurement is described. This technique is demonstrated with experimental data obtained at 4 Tesla and compared with techniques that use nonphase-encoded reference scan. Results from experimental studies indicate that the present approach reduces the ghost intensity by a factor of 2-3.

Algorithms↗

Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging.

An elliptical centric phase-encoding (PE) order is applied to steady-state 3DFT imaging as performed during a single breath-hold or following contrast agent administration. In a set of simulation, phantom, and in vivo experiments, this truly centric PE order is shown to be both more resistant to breathing artifact and more capable of suppressing undesirable venous signals that can arise following peak arterial enhancement than a number of other centric PE techniques that are presently in use. Unlike other PE orders, the elliptical centric ordering changes with the relative dimensions of the two PE fields of view and is optimal based on increasing k-space radius. It thus creates a temporally diminishing importance to the PE order. The specific advantages of such an acquisition are demonstrated.

Artifacts↗

Concomitant magnetic-field-induced artifacts in axial echo planar imaging.

When a linear magnetic field gradient is used, spatially higher-order magnetic fields are produced to satisfy the Maxwell equations. It has been observed that the higher-order magnetic field produced by the readout gradient causes axial echo planar images acquired with a horizontal solenoid magnet to shift along the phase-encoding direction and lose image intensities. Both the shift and intensity reduction become increasingly severe as the slice offset from the isocenter increases. These phenomena are quantitatively analyzed, and good correlation between experiments and theory has been established. The analysis also predicts a previously unreported Nyquist ghost on images with very large slice offsets. This ghost has been verified with computer simulations. Based on the analysis, several methods have been developed to eliminate the image shift, the intensity reduction, and the ghost. Selected methods have been implemented on a commercial scanner and proved effective in removing these image artifacts.

Artifacts↗

Removing the effect of SVD algorithmic artifacts present in quantitative MR perfusion studies.

Quantitative cerebral blood flow (CBF) values can be obtained from dynamic susceptibility contrast (DSC) MR perfusion studies using the standard singular value decomposition (sSVD) deconvolution algorithm. Reports in the literature from simulation and in vivo studies suggest that CBF estimates obtained using sSVD deconvolution depend on the arterial-tissue delay (ATD). By contrast, Fourier transform (FT) deconvolution produces CBF estimates that are independent of ATD. The diagnostic reliability of quantitative CBF measurements to define areas of normal tissue flow and tissue at risk is brought into doubt by such gross sensitivity to the specifics of the deconvolution approach. This variation of CBF values with ATD is shown to be an artifact associated with the current implementation of the sSVD deconvolution algorithm. A reformulated version of the SVD deconvolution algorithm (rSVD) is presented and compared to the standard SVD algorithm through simulation and patient case studies.

Algorithms↗

Diffusion measurements free of motion artifacts using intermolecular dipole-dipole interactions.

Diffusion encoding, or diffusion weighting, is commonly achieved by applying a pair of balanced pulsed-field gradients during spin evolution. An alternative way to obtain diffusion measurements is to select dipolar correlation distances using the distant dipolar field (DDF) in systems with abundant spin density, such as water in tissues. Diffusion weighting using this effect is unique in that the refocusing "gradient" is carried within the sample, and thus the macroscopic motion of the sample is not expected to interfere with signal formation. The experiments presented here demonstrate that in moving phantoms, the phase shift of the signal due to linear motion is minimal in diffusion-weighted (DW) DDF measurements, and that motion artifacts in images of moving phantoms and the abdomen of live mice are small compared to standard pulsed-field-gradient methods. The technique may facilitate the use of DWI in typically motion-prone regions such as the abdomen, lungs, and heart.

Abdomen↗

Automatic algorithm for correcting motion artifacts in time-resolved two-dimensional magnetic resonance angiography using convex projections.

Time-resolved contrast enhanced magnetic resonance angiography (MRA) may suffer from involuntary patient motion. It is noted that while MR signal change associated with motion is large in magnitude and has smooth phase variation in k-phase, signal change associated with vascular enhancement is small in magnitude and has rapid phase variation in k-space. Based upon this observation, a novel projection onto convex sets (POCS) algorithm is developed as an automatic iterative method to remove motion artifacts. The presented POCS algorithm consists of high-pass phase filtering and convex projections in both k-space and image space. Without input of detailed motion knowledge, motion effects are filtered out, while vasculature information is preserved. The proposed method can be effective for a large class of nonrigid motions, including through-plane motion. The algorithm is stable and converges quickly, usually within five iterations. A double-blind evaluation on a set of clinical MRA cases shows that a completely unsupervised version of the algorithm produces significantly better rank scores (P=0.038) when compared to angiograms produced manually by an experienced radiologist.

Algorithms↗

Compensation for spin-lock artifacts using an off-resonance rotary echo in T1rhooff-weighted imaging.

The origin of image artifacts in an off-resonance spin-locking experiment is shown to be imperfections in the excitation flip angle. A pulse sequence for off-resonance spin locking is implemented that compensates for imperfections in the excitation flip angle through an off-resonance rotary echo. The off-resonance rotary echo alternates the frequency offset and phase of the RF transmitter during two spin-locking pulses of equal duration. The underlying theory is detailed, and MR images demonstrate the effectiveness of the technique in agarose gel phantoms and in in vivo human brain at 3T.

Algorithms↗

Technical artifact simulating "motor axonopathy".

We describe 3 patients, referred for other problems, whose nerve conduction studies revealed low compound motor amplitudes, normal motor conduction velocities and normal sensory nerve studies, consistent with a motor axonopathy. EMG was normal. The unexpected nature of these findings precipitated a search for technical artifact. A partial transection of the active electrode was found. After replacement, repetition of the motor studies was normal. Our explanation was of a normal "reference" signal being subtracted from a present but diminished "active" signal.

Artifacts↗

Artifact-free quantification of free 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine in human plasma by electron capture-negative chemical ionization gas chromatography mass spectrometry and liquid chromatography-electrospray ionization tandem mass spectrometry.

Halogenation and nitration of biomolecules have been proposed as key mechanisms of host defense against bacteria, fungi, and viruses. Reactive oxidants also have the potential to damage host tissue, and they have been implicated in disease. In the current studies, we describe specific, sensitive, and quantitative methods for detecting three stable markers of oxidative damage: 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine. Our results indicate that electron capture-negative chemical ionization-gas chromatography/mass spectrometry (EC-NCI GC/MS) is 100-fold more sensitive than liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-MS/MS) for analyzing authentic 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine. Using an isotopomer of tyrosine to evaluate artifactual production of the analytes during sample preparation and analysis, we found that artifact generation was negligible with either technique. However, LC-MS/MS proved cumbersome for analyzing multiple samples because it required 1.5 h of run and equilibration time per analysis. In contrast, EC-NCI GC/MS required only 5 min of run time per analysis. Using EC-NCI GC/MS, we were able to detect and quantify attomole levels of free 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine in human plasma. Our results indicate that EC-NCI GC/MS is a sensitive and specific method for quantifying free 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine in biological fluids in a single, rapid analysis and that it avoids generating any of the analytes ex vivo.

Artifacts↗

Evidence that TSG101 aberrant transcripts are PCR artifacts.

Critical analysis of the data published so far concerning the TSG101 gene revealed some inconsistencies leading us to its re-evaluation in 80 breast, brain, colon, and neuroectodermal tumors and 37 normal tissue specimens. In this study, the occurrence of TSG101 cDNA aberrant transcripts was verified, but in addition we made observations that are in apparent conflict with the aberrant splicing theory supposed as the underlying mechanism for transcript formation: the location of most deletion breakpoints within exons and nonconformity of these putative splice sites with the highly conserved GT-AG rule, detection of insertions as well as nonreproducible and highly variable results in repeated RT-nested PCRs. Furthermore, we found that reamplification of full-length TSG101 cDNA products leads to the generation of deleted transcripts. In summary, for the first time we provide evidence that the acquired TSG101 transcripts are caused by PCR artifacts.

Artifacts↗

Computerized brain tissue classification of magnetic resonance images: a new approach to the problem of partial volume artifact.

Due to the finite spatial resolution of digital magnetic resonance images of the brain, and the complexity of anatomical interfaces between brain regions of different tissue type, it is inevitable that some voxels will represent a mixture of two or three different tissue types. Outright assignment of such "bipartial" or "tripartial" voxels to one class or another is more problematic and less reliable than assignment of "full-volume" voxels, wholly representative of a single tissue type. We have developed a computerized system for brain tissue classification of dual echo MR data, which uses a polychotomous logistic model for discriminant analysis, combined with a Bayes allocation rule incorporating differential prior probabilities, and spatial connectivity tests, to assign each voxel in the image to one of four possible classes: gray matter, white matter, cerebrospinal fluid, or unclassified. The system supports automated volumetric analysis of segmented images, has low operational overheads, and compares favorably with previous multivariate or "multispectral" approaches to brain MR image segmentation in terms of both validity (bootstrap misclassification rate = 3.3%) and interoperator reliability (intra-class correlation coefficients for all three tissue classes > 0.9). We argue that these improvements in performance stem from better methodological management of the related problems of non-Normality of MR signal intensity values and partial volume artifact.

Artifacts↗

Fixation of whole eyes: the role of fixative osmolarity in the production of tissue artifact.

BACKGROUND: Whole eyes fixed in 4% buffered formaldehyde (10% neutral buffered formalin) demonstrate a variety of artifacts, including separation of the neurosensory retina from the retinal pigment epithelium. We postulate that the osmolarity of 4% buffered formaldehyde causes contraction of the internal compartments of the eye leading to several artifactual changes commonly observed in routine histologic sections. METHODS: In part I of the study, enucleated animal eyes were examined histologically after immersion in different concentrations of formaldehyde. The variables of fixation and processing were kept constant except for the concentration and osmolarity of formaldehyde. In part II, enucleated animal eyes were used to empirically determine the optimal mixture of formaldehyde and glutaraldehyde for fixation based on subjective assessment of histologic sections. RESULTS: In the first part of the study, the post-fixed volume of the anterior chamber and vitreous increased as the concentration (and osmolarity) of formaldehyde decreased. In part II of the study, fixation of whole eyes was optimal with a mixture of 1% buffered formaldehyde and 1.25% glutaraldehyde. The neurosensory retina was less likely to detach from the retinal pigment epithelium, and the anterior chamber retained a more normal shape with this fixative. CONCLUSIONS: Volume contraction of whole eyes fixed in 4% buffered formaldehyde is caused by the relatively high osmolarity of the fixative. Immersion fixation of whole eyes for 36 h (or longer) in 1% buffered formaldehyde/1.25% glutaraldehyde reduces tissue distortion without compromising cellular preservation.

Animals↗

The no-reflow phenomenon is a post-mortem artifact.

Post-ischemic reperfusion impairment, ("no-reflow phenomenon"), was studied in rats subjected to 8-30 minutes of global brain ischemia. During ischemia, rapid and complete loss of cerebral blood flow, EEG and 31P-high energy phosphates (ATP/PCr) was observed. Brain intravascular perfusion defects were examined by injecting carbon black intravenously in a group of rats with stable cardiopulmonary function and in another group subjected to rapid thoracotomy and intraarterial infusion of the carbon marker. Results indicate that global brain ischemic or non-ischemic control rats given intraarterial carbon black after thoracotomy had varying degrees of vessel filling defects in brain resulting in "pale tissue areas" suggestive of impaired perfusion (no-reflow). All rats given carbon black intravenously whether global brain ischemic or not, showed normal cerebrovascular filling of the carbon black and absence of "pale tissue areas". In addition, post-ischemic cerebral reperfusion following 8-30 minutes global brain ischemia can reverse neuroelectric, energy metabolite and cerebral blood flow loss in rats whose cardiopulmonary function is not compromised. These findings indicate that the "no-reflow phenomenon" is an agonal or post-mortem artifact observed in the presence of cardiopulmonary failure.

Adenosine Triphosphate↗

Comparison of different patient positioning strategies to minimize shoulder girdle artifacts in head and neck CT.

The purpose of this study was to analyze different patient positioning strategies for minimizing artifacts of the shoulder girdle in head and neck CT. Standardized CT examinations of three positioning groups were compared (P: patients pushed their shoulders downwards; D: similar optimization by a pulling device; N: no particular positioning optimization). Parameters analyzed were the length of the cervical spine not being superimposed by the shoulder girdle as well as noise in the supraclavicular space. In groups P and D, the portion of the cervical spine not superimposed was significantly larger than in group N (P: 10.4 cm; D: 10.6 cm; N: 8.5 cm). At the supraclavicular space, noise decreased significantly (P: 12.5 HU; D: 12.1 HU; N: 17.7 HU). No significant differences between the two position-optimized groups (P and D) were detected. Optimized shoulder positioning by the patient increases image quality in CT head and neck imaging. The use of a pulling device offers no additional advantages.

Artifacts↗

[Brugada or not-Brugada: misdiagnosis of recorder-induced artifact].

The Brugada-Brugada syndrome is a life threatening cardiac arrhythmia that features syncopal events or aborted sudden death in combination with electrocardiographic characteristics (ST-segment elevation of V(1)-V(3) and right bundle branch block). Typical ECG alterations were recorded in a young man who was admitted to our hospital after syncope and a Brugada-Brugada syndrome was suspected. The following days similar pathological ECG recordings of other patients were noticed. The electrocardiographic artifact was diagnosed as being caused by incorrect handling of the ECG recorder.

Arrhythmias, Cardiac↗

The signature 10-hydroxy stearic acid thought to correlate with infectivity in oocysts of Cryptosporidium species is an artifact.

Heating or freezing leads to loss in infectivity of oocysts of Cryptosporidium parvum toward neonatal BALB/c mice and is reflected in the profile of the polar lipid fatty acids. Upon loss of infectivity, the ratio of polar lipid to neutral lipid fatty acid decreased and the relative proportions of 18:1n-9 also decreased; proportions of 18:2n-6 and 20:5n-6 increased, whereas the proportions of 16:0 remained constant with freezing. During these investigations, a novel fatty acid, 10-OH 18:0, was discovered in the glycolipid fraction. The identification of a fatty acid unique to species of Cryptosporidium was thought to provide a specific biomarker for this organism. Cryptosporidium also demonstrated fluctuations in absolute quantities of 10-OH 18:0 with events that lead to loss of infectivity. This led to the presumed correlation of this biomarker with infectious Cryptosporidium. The 10-OH 18:0 was putatively localized at the sn-2 position of phosphatidylethanolamine. High-performance liquid chromatography/electrospray ionization mass spectrometry revealed that the 10-OH 18:0 existed principally in the free fatty acid form. Herein, we establish that the free fatty acid 10-OH 18:0 was, in actuality, an artifact of the procedures for sample preparation.

Animals↗