Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RECORDS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Early detection of hepatic encephalopathy by recording visual evoked potential (VEP).

The visual evoked potential (VEP) record in response to a pattern stimulus is a non invasive and reliable method of detecting central and peripheral nerve system abnormalities. VEP recording have been used in animals with fulminant hepatic failure, and also in-patients with hepatic encephalopathy and acute severe hepatitis. Our aims were: a. to evaluate the potency of PVEP in assessing hepatic encephalopathy. b. to find the rate of pathologic PVEP in patients with advanced liver cirrhosis. VEP was recorded in 14 chronic liver cirrhotic patients (6 alcoholic, 6 HCV-related, 2 cryptogenic) and 14 controls. Patients with any neurologic abnormalities were excluded from the study. All patients were subjected to the Mental State Score (MSS) test, and venous blood ammonia was measured on the same day of VEP recording. In 10/14 (71%) patients some VEP recording abnormality was detected. In the cirrhotic patients, P100 latency was significantly longer (P < 0.05) than in controls. Low amplitude was observed in 8 patients compared to controls. Marked increase of N75 (3 patients) and marked increase of N145 (2 patients) were observed. Mean blood ammonia and MSS score were normal in all patients. No correlation was found between both MSS score and blood ammonia levels and the P100 delay. Five out of 10 patients with pathologic VEP developed hepatic encephalpathy during a follow-up of one year, compared to one out of 4 patients with no pathology on VEP recording. VEP recording may be a valuable tool in assessing patients with early hepatic encephalopathy and in predicting encephalopathy.

Adult↗

Semi-automatic analysis of unit channel conductance from voltage ramp records.

An IBM PC-compatible computer program, RAMP, for evaluation of single-channel recordings acquired using voltage ramp protocols is presented. The program uses semi-automatic procedures to make necessary corrections to a record (e.g. subtraction of baseline shift) and to measure all channel slope conductances as well as reversal potentials. The output is either a hardcopy of graphic display, which includes the calculated parameters, or data in ASCII format for further use (e.g. plots using various graphic software). Originally, the software was developed for the evaluation of voltage ramp records of single channel data from maxi chloride channels in myoblasts of a muscle cell line (Hurnák and Zachar 1992). Records from these membrane patches were also used in this work to demonstrate basic principles of the software and its practical use in evaluating single channel records obtained in response to the application of voltage ramps. The channel conductances calculated from ramp records were compared with those obtained by classical evaluation procedures from voltage step records.

Animals↗

Arm movement and EMG mean power frequency in the trapezius muscle: a comparison between surface and intramuscular recording techniques.

In a previous study it has been shown that there is a systematic variation of the EMG mean power frequency recorded under dynamic conditions with surface electrodes from non-fatigued trapezius muscle. The variation was most pronounced in relation to shoulder joint angle. The aim of the present study was to find out whether this variation was caused by geometric factors such as electrode displacement, or by neuromuscular factors within the muscle. A comparison has been made between surface and intramuscular recordings. EMG was recorded with standard surface electrodes and with a monopolar "hooked wire" intramuscular electrode. The recordings were analyzed for calculation of mean power frequency (MPF) and root mean squared (RMS) signal level. For MPF we found a low, but statistically significant correlation (r = 0.30) between surface and intramuscular recordings. For RMS the corresponding correlation was high (r = 0.92). Analysis of variance showed a high proportion of explained variance related to the shoulder joint angle for surface recordings, but not for intramuscular recordings. The results were confirmed in the regression analysis. The results indicate that the observed variation is largely caused by geometric displacement of the surface electrodes and not by intrinsic neuro-muscular factors.

Adult↗

Exploration of multifocal rod electroretinograms recording in human.

PURPOSE: To test the feasibility of recording rod multifocal electroretinograms (ERG) in humans and observe appropriate recording conditions. METHODS: Multifocal rod ERG were recorded using a stimulus array of 61 equalsized hexagons in two normal subjects after the dark adaptation. Flashes were blue (W47B). Blank frames between two successive flashes of hexagons varied from 0 to 14. Length of the m-sequence, bandwidth, flash frequency, flash intensities and background intensities were changed to obtain appropriate recording conditions for the clinical use. RESULTS: Multifocal rod ERG were clearly recordable and well formed. They had an early implicit time, very small negative wave and a late implicit time, large positive wave. The positive wave was bimodal, whose timing and waveform were similar to the full-field rod ERG. The local response amplitudes can be suppressed with increase in flash frequency or background intensity, decrease in flash intensity or the size of stimulus elements. CONCLUSIONS: Multifocal rod ERG can be recorded in human and can provide topographical maps of retinal function that have clinical usage. 2(12)-1 m-sequence length, 3F blank frames and 3 - 300 Hz bandwidth were suggested to appropriate recording conditions.

Adult↗

[Comparison of fetal ECG recordings using STAN S21 analyser and external ECG of newborns, in relation to enzymatic ischaemic markers and acid-base parameters in umbilical blood].

DESIGN: Neonatal hypoxia is often responsible for myocardial ischaemia. To evaluate cardiac involvement in neonates, fetal and neonatal ECG recordings have been performed and parameters indicating heart dysfunction have been analysed. OBJECTIVES: Our interest has been focused on analysis of fetal electrocardiogram recordings using STAN S21 analyser during labour, compared to newborns ECG recordings in the first 12 hours of life, in relation to enzymatic ischaemic markers and acid-base parameters in umbilical blood. MATERIALS AND METHODS: The data were collected from 8 term fetuses and neonates, continuously monitored in the first and second stage of labor. All ECG were recorded with a single spiral scalp electrode connected to the STAN S21 analyser. After birth, umbilical venous blood samples have been collected for determination of pH, base excess and concentrations of creatinine kinase (CK), its isoenzyme (CK-MB), myoglobin, lactate dehydrogenase (LDH), alanine transaminase, aspartate aminotransferase. In the first 12 hours of life, external neonatal ECG was performed. RESULTS: P,QRS and T waves have been present in all cases recorded. There was no suggestion of fetal hypoxia in any case. A little variety of QRS complex has been observed. In our study, we didn't noticed any pathological changes in ECG recordings. The QT interval, corrected by the Bazett formula was normal in all cases. Nevertheless correct ECG recordings, increase of enzymatic ischaemic markers (LDH, CK,CK-MB) has been observed in two cases, corresponding to the normal fetal outcome.

Acid-Base Equilibrium↗

[Clinical evaluation of ECG at the onset subjective symptoms using real-time analysis electrocardiograph (event recorder)].

Examination of patient complaining of palpitation, chest pain and chest discomfort is usually performed by 12-lead electrocardiograph. However, the recording time is short and there are few opportunities to capture an ECG demonstrating conditions during subjective symptoms. To investigate the cause, we need to obtain an ECG during subjective symptoms. Thus, we frequently use a Holter ECG, which can be recorded for 24 hours. However, some patients have a low frequency of subjective symptoms, which may not appear during a 24-hour examination. We used a real-time electrocardiograph (Event Recorder CG-6106 made by Card Guard Scientific Survival Limited) as a monitor during subjective symptoms. Thereafter, ECG findings at the onset of subjective symptoms could be analyzed in 30 patients who did not have a clear cardiac disease. In this examination, arrhythmia was recorded in 25 of 30 cases. Although in these cases ECG during subjective symptoms could not be captured even when Holter examination was performed several times ECG during subjective symptoms was captured using an Event Recorder. This method using an Event Recorder is simple and convenient, moreover, is considered very useful for investigation of subjective symptoms. In the future, the use of an Event Recorder for heart-health-care in the daily life of healthy people and/or cardiac disease patient is highly anticipated.

Adult↗

Assessment of ambulatory blood pressure recorders: accuracy and clinical performance.

There are now more than ten different manufacturers of non-invasive, portable blood pressure monitors in North America, Europe, and Japan. These ambulatory blood pressure recorders measure blood pressure by either auscultatory or oscillometric methodology. Technologic advances in the recorders have resulted in reduction in monitor size, reduction in or absence of motor noise during cuff inflation, ability to program the recorder without an external computer system, and enhanced precision. Recently, there has been concern that more structured validation protocols have not been implemented prior to the widespread marking of ambulatory blood pressure recorders. There is a need for proper assessment of recorders prior to use in clinical research or practice. Data on several existing recorders suggest that while most are reasonably accurate during resting measurements, many lose this accuracy during motion, and clinical performance may vary among the monitors. Validation studies of ambulatory recorders should include comparison with mercury column and intra-arterial determinations, resting and motion measurements, and assessment of clinical performance in hypertensive patients.

Blood Pressure↗

Single-channel K+ currents recorded from the somatic and dendritic regions of cerebellar Purkinje neurons in culture.

Voltage-sensitive K+ channels were studied in rat cerebellar Purkinje neurons in culture using the single-channel recording technique. Recordings in the cell-attached and outside-out configuration revealed multiple voltage-sensitive K+ channel types in patches from both the somatic and the dendritic regions. K+ channel types were present in all patches studied. The same channel types were observed in somatic and dendritic recordings. Channel types were identified by reversal potential, single-channel conductance, voltage sensitivity, and patterns of activity. In cell-attached patches recorded under physiological conditions, 3 channel types were identified. Mean single-channel conductances were 92, 57, and 12 pS. All 3 channel types were activated by membrane depolarization. Similar channel types were identified in inside-out and outside-out patches recorded under physiological conditions. Two additional channel types were identified in the outside-out patches, with mean single-channel conductances of 41 and 26 pS. In cell-attached recordings under symmetrical K+ conditions, 6 channel types were identified. Mean single-channel conductances were 222, 134, 39, 25, 14, and 15 pS. Channel types with mean conductances of 222, 134, and 39 pS required membrane depolarization for activation. A comparison of channel properties indicated that these channel types correlated with the 3 channel types observed in cell-attached patches under physiological conditions. The 3 smaller-conductance channel types (25, 14, and 15 pS) were active at potentials around rest or at hyperpolarized membrane potentials. Two K+ channel types (39 and 25 pS) were commonly associated with the late phase of extracellularly recorded spontaneous spike events, suggesting a functional role in the repolarizing phase of somatic and dendritic action potentials. These results demonstrate that voltage-sensitive K+ channels are a prominent component of both the somatic and the dendritic membrane of the cerebellar Purkinje neuron and support the view that multiple voltage-sensitive K+ channel types contribute to the membrane functions of both cellular regions in this CNS neuronal type.

Animals↗

The NCHS pilot project to link birth and infant death records: stage 1.

The National Center for Health Statistics (NCHS) has completed a pilot test of its method to develop national linked files of birth and infant death records. A linked file of the 1982 birth cohort was produced that successfully linked 97 percent of the death records for infants who died in a nine-State area. The method NCHS uses to create national linked files takes full advantage of two existing data sources: the NCHS fully coded natality and mortality files and State files of matched births and infant deaths. For the nine-State pilot area, NCHS obtained computerized linked files from the States and extracted from them the certificate numbers on matching birth and death records. With the use of these numbers, NCHS selected and linked birth and death statistical records from its final natality and mortality files, thus creating new statistical linked records. The initial match rate of 93.2 percent for the project's linked record file was increased to 96.7 percent as a result of efforts by the pilot States to complete the matching of birth and infant death records. Matching in the nine-State linked file appears to be highly accurate, based on the results of two evaluation studies. In the second stage of the project, now underway, NCHS will continue to evaluate and improve State and national linked files for the four birth cohorts of 1983-86. With funding from the Department of Health and Human Services' Office of the Assistant Secretary for Planning and Evaluation, stage 2 will be conducted in collaboration with each of the 50 States, the District of Columbia, Puerto Rico, the Virgin Islands, and New York City, an independent registration area.

Birth Certificates↗

[Studies on the cardiotocograms recorded by a new system with 1 MHz ultrasound and autocorrelation heart rate meter].

Improved FHR records were obtained by the use of a new 1 MHz ultrasound transducer and autocorrelation heart rate meter. The results were compared with conventional 2.5 MHz continuous wave ultrasound device. The rate of the loss of FHR recording was 0 to 6.6% (2.8 +/- 2.1%) in the new device, and it was 2.1 to 23.5% (8.7 +/- 6.2%) in the old one. The loss of FHR record in the 2nd stage of labor was 3.2% when 1 MHz ultrasound and new device were used, and it was 2.0% with direct fetal ECG signal using scalp electrode and the same device. More clear record was obtained with use of ultrasound at a crowning of fetal head than that of direct fetal ECG. In the use of 1 MHz ultrasound, 51% cases in 55 patients showed undisturbed FHR record 1 minute before delivery of the fetus. Slightly noisy but analysable FHR record was obtained in 36%. Hence, the FHR records were clearly evaluated until 1 minute before delivery of the infant in 87% of the cases. Maternal heart rate signal was mixed with FHR in 2 cases in routine intrapartum ultrasonic FHR monitoring. However, the maternal signal disappeared after moving the transducer to other position where fatal heart beat was more clearly detected.

Electrocardiography↗

The role of home and ambulatory blood pressure recording in the management of hypertension.

A review of the literature shows that doctor-recorded measurement (DRM) of blood pressure is higher than patient-recorded measurement (PRM) by either home-recording or ambulatory measurement. The role of home-recording and ambulatory measurement as a means of supplementing doctor-recorded measurement is discussed. The results of two studies comparing home-recording with clinic and ambulatory blood pressure showed that home-recording of blood pressure did not lower blood pressure.

Blood Pressure Determination↗

[Incidence of identification and configuration variants of the NSEP signal in relation to the recording site and measuring moment].

The component evaluation of the spinal and cortical recorded SEP-signals of thirty healthy volunteers after stimulation of the median nerve at the wrist gave information about variation of waveforms and frequency of peak identification with respect to the position of the active electrode and the repetition of the SEP recording. Basically one can distinguish three main groups of NSEP waveforms (Fig. 1). Firstly the "classical form" (i.e. N11 in the ascending part, N13 at the highest peak of the NSEP main component and N14 in the descending part of the curve). Secondly the "plateau-form" and thirdly the "polypeak form" (i.e. many peaks of the same amplitude). The latter two configurations were seen in more than a third of the evaluated NSEP maincomponents. Neither the position of the active electrode (C2 and C7) nor repetition of the SEP recording were found to have significant influence on the waveform. The position of the active electrode influenced the number of identificable peaks: the early components (N9 and N11) were more often recognisable when the recording was made over the lower neckregion (C7), N14 when the recording was made over the upper neckregion (C2). N13 was always identificable in both electrode positions. The repetition of the SEP recordings immediately after the first run is helpful if there was difficulty in identifying the peaks. The normal values of the SEP latency of the spinal and cortical recorded signals were evaluated taking above mentioned criteria into account.

Adult↗

Percutaneous recording of evoked spinal cord potentials of dogs.

Using a signal-averaging system, potentials evoked by stimulation of nerves in the limbs or tail of dogs were recorded through needle electrodes placed adjacent to the vertebral column. Cord dorsum potentials (consisting of a small triphasic wave followed by a large negative peak and a subsequent slow positive phase) were recorded at the level of the lumbar enlargement after stimulating nerves in the pelvic limb or tail, and at the cervical enlargement after forelimb nerve stimulation. Ascending volleys were recorded from appropriate levels of the spinal cord or from regions of the cauda equina. After forelimb nerve stimulation, a large slow potential, reflecting activation of an unidentified neuronal pool, was recorded at the level of the first cervical vertebra. Percutaneously recorded potentials were closely similar to those recorded directly from the dura mater, suggesting that the method accurately recorded spinal cord electrical events and, therefore, might be of use in studying clinical or experimental spinal cord disease.

Animals↗

[Comparison of 3 methods of recording esophageal pH in the diagnosis of gastroesophageal acid reflux].

The aim of this prospective work was to analyze the results of 3 methods of esophageal pH recording (i. e. short-term pH test, 3-hr postprandial recordings, and 12-hr nocturnal pH recording) in 47 patients with suspected gastroesophageal reflux. Nocturnal pH recording was used as a reference for evaluation of the diagnostic value of the 2 other pH tests. Normal ranges were established from 20 control subjects. Esophageal endoscopy with biopsies were performed systematically in order to evaluate the relationship between pH results and the grades of esophagitis. According to the results of nocturnal pH recordings, 32 patients were considered to suffer from acid gastroesophageal reflux and 15 patients as being free of reflux. The sensitivity and specificity of the pH measurements were 0.94 and 0.13 for the short-term pH test and 0.91 and 0.80 for 3-hr postprandial recordings respectively. The total duration of reflux (expressed as a percentage of total duration of the test) was the most discriminative parameter for the diagnosis of reflux and was simpler to determine than previously described pH scores. Because of the absence of lamina propria in the biopsy specimens obtained at endoscopy, histological diagnosis of esophagitis was possible in only 35 patients (74 p. 100). No relationship was found between the grade of esophagitis and the results of short-term pH tests. On the other hand, the mean duration of reflux episodes, the duration of the longest episode, the total duration of reflux measured by 12-hr nocturnal pH recording, and the number of low pH reflux episodes determined by postprandial tests were significantly higher in patients with macroscopic lesions than in those with normal endoscopic aspect or mild (histological) lesions of esophagitis.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Effects of diazepam on evoked potential recorded from basal medial amygdaloid nucleus, lateral hypothalamus and midbrain reticular formation (author's transl)].

The evoked potential in the lateral hypothalamus (LH) recorded by stimulation of basal medial amygdaloid nucleus (Abm) showed a triphasic pattern and diazepam (2 mg/kg, i. p.) decreased the late component. The evoked potential in the midbrain reticular formation (MRF) recorded by stimulation of Abm showed a fast component with a relatively short latency followed by a biphasic late component and diazepam decreased the late component. Though the evoked potential in the Abm recorded by stimulation of LH showed a triphasic pattern, diazepam had no influence on the amplitude. Diazepam increased markedly the amplitude of evoked potential in the MRF recorded by stimulation of LH. Diazepam was ineffective on the evoked potential in the Abm recorded by stimulation of MRF. Diazepam decreased markedly the late component of evoked potential in the LH recorded by stimulation of MRF. These results suggest that the depression of emotional behavior by diazepam may be particularly related to the fact that the evoked potential in the LH recorded by stimulation of Abm was decreased by diazepam.

Amygdala↗

[Continuous recordings of the echocardiogram and electrocardiogram through the night in patients with nocturnal angina: "All-night echocardiography"].

Continuous observation of the left ventricular (LV) wall motion through the night has not been reported yet. So we developed the long-term recording system of the echocardiogram through all of the night, which was proved useful in a clinical setting. In order to record a long-term echocardiogram, a superimposed echocardiogram of each cardiac cycle was developed on the monitor television by using QRS complex as its trigger. This monitor view has a capacity to display such an echocardiogram with 2-channel electrocardiogram (ECG). Sudden changes of the cardiac motion during the recording were easily detected on the monitor view. These pictures were also recorded on the video cassette recorder through the video camera. We call this system "All-night echocardiography". Complete review of the video tape for 10 hours was possible for only 50 minutes by changing the speed of the review tape (one-twelfth of real time). A probe (Monitoring Probe) was fixed on the chest wall during the recording. "All-night echocardiograms" were recorded in eight patients for 10 hours in total 10 nights. LV posterior wall (PW) monitoring was succeeded in 3 patients for 4 nights during the anginal attack. Systolic motion of LVPW was decreased with ST elevation in a VF in the simultaneous ECG during spontaneous attack (Fig. 5).

Angina Pectoris↗

A comparison of close proximity concentric and modified single fiber electromyographic recordings from extensor digitorum communis.

Using a combined concentric (CN) and modified single fiber (MSF) electromyography (EMG) needle electrode with both recording surfaces at the tip approximately 25 microns apart, 30 motor unit action potentials (MUAP) were recorded from one extensor digitorum communis (EDC) muscle, triggering from the CN and averaging both the CN and MSF recordings. Correlations of MUAP amplitude (r = 0.767), number of turns (r = 0.839), and number of negative-going-positive-going turn (NT) (r = 0.737) between the CN and MSF recordings were statistically significant (p < 0.001). For NTs common to both recordings, correlations of rise time (r = 0.866), amplitude (r = 0.816), and interpeak interval (IPI) (r = 0.999) were statistically significant (p < 0.001). Mean +/- SD single fiber potentials (SFP), approximate SFP with rise times less than 500 microseconds, and NTs for the MSF recordings and NTs for the CN recordings were 0.73 +/- 0.69, 1.20 +/- 0.48, 1.83 +/- 0.87, and 1.93 +/- 0.78, respectively. This study supports evidence that one or a few SFP contribute to the spike component of the MUAP.

Action Potentials↗

[External recording of His bundle electrical activity (author's transl)].

A noninvasive method to record His' potentials in man is described. In several patients who needed intracardiac recording, a bipolar lead was placed across the chest, directed as conveniently as possible for the recording of His bundle electrical activity. A signal filtered (70-300 Hz) and amplified (X 100.000), was processed by a multichannel analyzer for averaging. The temporal regime of the averager was determined by a trigger which established a fiducial point on the ECG. For this purpose a QRS detector fed to a normal peripheral bipolar lead was used. The temporal stability of the system was continually checked in order to reject the recordings over the limits of +/- 1 msec. The computer program was chosen in order to select a window (usually 200 msec) which occurred up to 150 msec prior and 50 msec after the trigger signal. The sampling rate was 5 KHz for 1024 samples and the sweep counts were fixed from 128 to 512. At the same time, the D1, D2 and D3 were recorded in the other three channels of the analyzer for a more accurate measurement of the HV interval. Then an example comparing the external and interval recording was presented. Finally several external recordings were measured and the exact reproducibility of the G wave was confirmed. In conclusion we can say that the G wave is significant and suggests the electrical activity of the bundle of His.

Bundle of His↗