Quantitative transcutaneous arterial velocity measurements with Doppler flowmeters.

A controlled in vitro and in vivo comparative evaluation of four Doppler ultrasonic blood velocimeters was performed to evaluate their ability to measure fluid velocity throughout a wide range of flow rates and velocity profiles, during both steady and pulsatile flow. The instruments tested were the Versatone Bidirectional Doppler M-9, the Sonicaid BV380, the Parks 806 B, and the Delalande DUD 400. All instruments responded linearly to velocities of from 5 to 70 cm/s, and were accurate to within 5% through a wide range of in vitro changes in velocity, pulse frequency, and cross-sectional velocity profile. Quantitative velocity measurements and their derivatives are an inexpensive, simple, and useful tool in the evaluation conditions of patients with peripheral vascular disease, and widespread clinical trials of their value are appropriate at this time.

Animals↗

Three-dimensional time-of-flight MR angiography using selective inversion recovery RAGE with fat saturation and ECG-triggering: application to renal arteries.

A three-dimensional (3D), ECG-triggered, selective inversion recovery (SIR) rapid gradient-echo (RAGE) technique is proposed to obtain MR angiograms of the main renal arteries. By using the selective inversion recovery and fat saturation, the background is significantly suppressed while blood maintains a high signal intensity as compared with conventional 3D time-of-flight (TOF) MR angiography. The sequence is ECG-triggered so that blood in-flow is maximized during systole, and intravoxel dephasing and pulsatile flow artifacts are minimized by collecting data during diastole. As a result, vessel boundary blurring and ghosting artifacts due to background motion are dramatically reduced, and the conspicuity and lumen definition of the arteries are significantly improved. High-quality MR angiograms of the main renal arteries with excellent blood/tissue contrast and suppression of motion artifacts have been consistently obtained for normal volunteers, with the length of visualization being 51 +/- 07 mm for the left, and 57 +/- 06 mm for the right renal arteries, significantly greater than using conventional 3D TOF pulse sequences. Statistical analysis was performed by using a one-sided Student's t test.

Angiography↗

Qualitative venous Doppler waveform analysis improves prediction of critical perinatal outcomes in premature growth-restricted fetuses.

BACKGROUND: Our aim was to test the hypothesis that qualitative ductus venosus and umbilical venous Doppler analysis improves prediction of critical perinatal outcomes in preterm growth-restricted fetuses with abnormal placental function. METHODS: Patients with suspected intrauterine growth restriction (IUGR) underwent uniform fetal assessment including umbilical artery (UA), ductus venosus (DV) and umbilical vein (UV) Doppler. Absent or reversed UA end-diastolic velocity (UA-AREDV), absence or reversal of atrial systolic blood flow velocity in the DV (DV-RAV) and pulsatile flow in the umbilical vein (P-UV) were examined for their efficacy to predict critical outcomes (stillbirth, neonatal death, perinatal death, acidemia and birth asphyxia) before 37 weeks' gestation. RESULTS: Seventeen (7.6%) stillbirths and 16 (7.1%) neonatal deaths were observed among 224 IUGR fetuses. Forty-one neonates were acidemic (19.8%) and seven (3.1%) had birth asphyxia. Logistic regression showed that UA-AREDV had the strongest association with perinatal mortality (R(2) = 0.49, P < 0.001), stillbirth (R(2) = 0.48, P < 0.001) and acidemia (R(2) = 0.22, P = 0.002) while neonatal death was most strongly related to DV-RAV and P-UV (R(2) = 0.33, P = 0.007). UA waveform analysis offered the highest sensitivity and negative predictive value and DV-RAV and P-UV had the best specificity and positive predictive values for outcome prediction. Overall, DV-RAV or P-UV offered the best prediction of acidemia and neonatal and perinatal death irrespective of the UA waveform. In fetuses with UA-AREDV, prediction of asphyxia and stillbirth was significantly enhanced by venous Doppler. CONCLUSION: Prediction of critical perinatal outcomes is improved when venous and umbilical artery qualitative waveform analysis is combined. The incorporation of venous Doppler into fetal surveillance is therefore strongly suggested for all preterm IUGR fetuses.

Asphyxia Neonatorum↗

In vitro evaluation of a rheolytic thrombectomy system for clot removal from five different temporary vena cava filters.

PURPOSE: To evaluate the feasibility of thrombus removal from temporary vena cava filters using a rheolytic thrombectomy device and to assess the embolization rate of this procedure. METHODS: Five temporary vena cava filters together with porcine thrombi were placed in a vena cava flow model (semitranslucent silicone tube of 23 mm diameter, pulsatile flow at a mean flow rate of 4 L/min). A rheolytic thrombectomy system (Hydrolyser) was used with a 9 Fr guiding catheter to remove the clots. The effluent was passed through filters of different size and the amount of embolized particles as well as the remaining thrombus were measured. RESULTS: Thrombus removal rates ranged from 85% to 100%. Embolization rates between 47% and 60% were calculated for the different filters. CONCLUSION: The Hydrolyser is able to remove sufficiently high amounts of thrombus from temporary vena cava filters. However, the amount of embolized particles makes it impossible to utilize this method without special precautions against embolization.

Animals↗

A simple method to determine anastomotic quality of coronary artery bypass grafting in the operating room.

Anastomotic quality of coronary artery bypass grafting is directly associated with peri-operative and long-term clinical results. In this study, we investigated a cut-off value for intra-operative flow measurement. This value could be of use to a surgeon in determining the anastomotic quality of grafts. Intra-operative transit-time flow variables (mean flow, pulsatility index, % efficiency, fast Fourier transformation (FFT) of the flow curve) and the 2-week post-operative angiographic findings were examined in 66 coronary artery bypass grafts, including 33 internal thoracic arteries. There were significant differences between patent and non patent grafts in all of the intra-operative flow parameters. Only the FFT ratio, the ratio of powers of the fundamental frequency and its first harmonic, could be utilized as a cut-off value to distinguish patent from non patent grafts. All stenotic or occluded grafts showed an intra-operative FFT ratio of <1.0, while all patent grafts yielded a ratio of >1.0. Based upon these results, we concluded that power spectral analysis of flow measurement might be useful for intra-operative differential diagnosis of the anastomotic quality in coronary artery bypass grafting.

Aged↗

Effects of left ventricular assist device on cardiac function: experimental study of relationship between pump flow and left ventricular diastolic function.

The left ventricular assist device (LVAD) with centrifugal pump has two characteristics. One is a pump flow wave of the centrifugal pump, consisting of the pulsatile flow of the native heart and the nonpulsatile flow of the centrifugal pump. The other is that the centrifugal pump fills from the native heart not only in the systolic phase, but also in the diastolic phase. In the case of the apex outlet LVAD with centrifugal pump, blood flows from the left atrium through the left ventricle to the pump. Pump flow is regulated by preload, and preload is regulated by diastolic hemodynamics. The aim of this study is to analyze the relationship between pump flow and the diastolic hemodynamics of the native heart. Ten anesthetized intact pigs were studied after placement of an LVAD. Data were recorded with the LVAD off (control) and the LVAD on. The assist rate was changed to 25%, 50%, and 75%. The indexes of left ventricular (LV) diastolic function included LV myocardial relaxation (time constant of isovolumic pressure decay [Tau] and maximum negative dP/dt [LV dP/dt min]) and LV filling (peak filling rate [PFR], time to peak filling rate [tPFR], and diastolic filling time [DFT]). Stroke volume decreased significantly in 75% assist. LV end-systolic pressure decreased significantly in 50% and 75% assist. LV end-diastolic volume decreased as assist rate increased, but there were no significant changes. Stroke work decreased significantly in 50% and 75% assist. LV dP/dt min decreased significantly in 50% and 75% assist. Tau prolonged as assist rate increased, but there were no significant changes. DFT shortened significantly in 75% assist. PFR increased significantly in 75% assist. tPFR shortened significantly in 50% and 75% assist. In this study, LV relaxation delayed as an increasing of pump assist rate, but it suggested a result of reduction of cardiac work. Also, it was suggested that LVAD increases the pressure difference between the left atrium and the left ventricle in the diastolic phase. This phenomenon is due to the filling of the left ventricle. In this study it was suggested that as pump assist rate increases, it is more effective to keep cardiac function in the diastolic phase.

Animals↗

Quantification of instantaneous flow rate and dynamically changing effective orifice area using a geometry independent three-dimensional digital color Doppler method: An in vitro study mimicking mitral regurgitation.

OBJECTIVE: Our study was intended to test the accuracy of a 3-dimensional (3D) digital color Doppler flow convergence (FC) method for assessing the effective orifice area (EOA) in a new dynamic orifice model mimicking a variety of mitral regurgitation. BACKGROUND: FC surface area methods for detecting EOA have been reported to be useful for quantifying the severity of valvular regurgitation. With our new 3D digital direct FC method, all raw velocity data are available and variable Nyquist limits can be selected for computation of direct FC surface area for computing instantaneous flow rate and temporal change of EOA. METHODS: A 7.0-MHz multiplane transesophageal probe from an ultrasound system (ATL HDI 5000) was linked and controlled by a computer workstation to provide 3D images. Three differently shaped latex orifices (zigzag, arc, and straight slit, each with cutting-edge length of 1 cm) were used to mimic the dynamic orifice of mitral regurgitation. 3D FC surface computation was performed on parallel slices through the 3D data set at aliasing velocities (14-48 cm/s) selected to maximize the regularity and minimize lateral dropout of the visualized 3D FC at 5 points per cardiac cycle. Using continuous wave velocity for each, 3D-calculated EOA was compared with EOA determined by using continuous wave Doppler and the flow rate from a reference ultrasonic flow meter. Simultaneous digital video images were also recorded to define the actual orifice size for 9 stroke volumes (15-55 mL/beat with maximum flow rates 45-182 mL/s). RESULTS: Over the 9 pulsatile flow states and 3 orifices, 3D FC EOAs (0.05-0.63 cm(2)) from different phases of the cardiac cycle in each pump setting correlated well with reference EOA (r = 0.89-0.92, SEE = 0.027-0.055cm(2)) and they also correlated well with digital video images of the actual orifice peak (r = 0.97-0.98, SEE = 0.016-0.019 cm(2)), although they were consistently smaller, as expected by the contraction coefficient. CONCLUSION: The digital 3D FC method can accurately predict flow rate, and, thus, EOA (in conjunction with continuous wave Doppler), because it allows direct FC surface measurement despite temporal variability of FC shape.

Blood Flow Velocity↗

Limitation of pulsatility index as a diagnostic tool in the newborn.

Pulsatile flow in the anterior cerebral arteries was studied and pulsatility index (PI) calculated by 3 observers in 10 newborn infants in order to establish the reproducibility of a noninvasive Doppler technique. No significant differences were noted among the observers and the estimated error of observation was 0.073. Subsequently, 14 healthy preterm infants were studied daily by a single observer in an attempt to establish a normal range of PI for prematures in the first 5 days of life. The babies were concomitantly studied with serial ultrasound examinations to rule out intracranial hemorrhage. The study revealed good interobserver reliability but wide variation of PI in normal, healthy premature infants with values falling within abnormal ranges previously described in asphyxiated infants or those with intraventricular hemorrhage (IVH). Caution is advised in using the PI to predict outcome.

Cerebral Arteries↗

Flow-induced release of endothelium-derived relaxing factor.

To analyze the potential mediator(s) involved in flow-induced endothelium-dependent vasodilation, we measured the wall tension of intraluminally perfused canine femoral artery segments and compared the content of 6-ketoprostaglandin F1 alpha (determined by radioimmunoassay) and the relaxing activity of the effluent (determined by bioassay on canine coronary artery rings). During perfusion at a steady flow of 2 ml/min the effluent contained 6-keto-prostaglandin F1 alpha and relaxed the bioassay rings. Sudden increase in steady flow rate to 4 ml/min, or the introduction of pulsatile flow, increased the release of 6-keto-prostaglandin F1 alpha and induced further relaxations of the bioassay ring. No relaxations were observed with the effluent passing through a femoral artery segment without endothelium. Indomethacin significantly depressed the release of 6-keto-prostaglandin F1 alpha during increases in flow but had no significant effect on the relaxing activity of the effluent. In the presence of indomethacin, increases in flow produced significant relaxation in the perfused femoral artery segments with endothelium. Superoxide dismutase restored the relaxing activity of the effluent during increases in flow at a transit time of 30 seconds. These data demonstrate that in addition to prostacyclin, flow triggers the release of another relaxing substance (or substances) from vascular endothelial cells that has characteristics similar to the endothelium-derived relaxing factor released by acetylcholine.

6-Ketoprostaglandin F1 alpha↗

Phasic blood flow patterns in the common umbilical vein of fetal sheep during umbilical cord occlusion and the influence of autonomic nervous system blockade.

The blood flow pattern in the common umbilical vein is under normal conditions nonpulsatile in contrast to the flow in the fetal inferior vena cava. We observed pulsatile flow patterns in the common umbilical vein of fetal lambs during changes in the fetal hemodynamic equilibrium. These pulsations may influence the mixing of oxygen-rich ductus venosus blood and oxygen-poor inferior vena cava blood. This study deals with the phasic changes in umbilical venous blood flow during cord occlusion. The experiments were performed in eight chronically instrumented fetal lambs between 114 and 133 days gestation (term 146 days). Umbilical venous blood flow was measured with an electromagnetic flow transducer around the intraabdominal common part of both umbilical veins. The fetuses were provided with catheter in the fetal abdominal aorta and with electrodes for monitoring arterial blood pressure and heart rate. Occlusion of the umbilical cord was performed by means of an inflatable balloon occluder around the total cord (occlusion time 20 to 90 seconds). Occlusions were performed in fetuses with an intact autonomic nervous system and after blockade of the alpha-adrenergic, beta-adrenergic or cholinergic part of the autonomic nervous system.

Animals↗

Correlation of hemodynamic impact and morphologic degree of renal artery stenosis in a canine model.

In a noninvasive comprehensive magnetic resonance (MR) examination, the morphologic degree of renal artery stenosis was correlated to corresponding changes in renal artery flow dynamics. Different degrees of stenosis were created with the use of a chronically implanted inflatable arterial cuff in seven dogs. For each degree of stenosis, an ultrafast three-dimensional gadolinium MR angiography with high spatial resolution was performed, followed by cardiac-gated MR flow measurements with high temporal resolution for determination of pulsatile flow profiles and mean flow. Flow was also measured by a chronically implanted flow probe. In three of the dogs, trans-stenotic pressure gradients (DeltaP) also were measured via implanted catheters. Five different degrees of stenosis could be differentiated in the MR angiograms (0%, 30%, 50%, 80%, >90%). The MR flow data agreed with the flow probe within +/-20%. Stenoses between 30 and 80% gradually reduced the early systolic peak (Max(1)) of the flow profile but only minimally affected the midsystolic peak (Max(2)) or mean flow. Stenoses of more than 90% significantly depressed mean flow by more than 50%. The ratio between Max(1) and Max(2) (Rmax(1/2)) gradually fell with the degree of stenosis. The onset of significant mean flow reduction and DeltaP was indicated by a drop of Rmax(1/2) below 1 to 1.2. Thus, the analysis of high-resolution flow profiles allows detection of early hemodynamic changes even at degrees of stenoses not associated with a reduction of mean flow. Rmax(1/2) allows differentiation of the grade of hemodynamic compromise for a given morphologic stenosis independent of mean flow in a single comprehensive MR examination.

Angiotensin II↗

Blood flow velocity and pulsatile diameter changes in the fetal descending aorta: a longitudinal study.

Blood flow velocity and pulsatile diameter changes in the fetal descending aorta were measured subsequently with pulsed Doppler ultrasonography and phase-locked echo-tracking technique, respectively. Blood flow velocity and pulse-wave curves with equal beat-to-beat intervals were synchronized by external fetal electrocardiogram. The systolic increase in blood flow velocity and in vessel diameter started simultaneously. The velocity peak preceded the diameter peak by a significant margin (p in the range 0.0001 to 0.0014). The time interval was more pronounced in the thoracic than in the abdominal part of the aorta and was slightly smaller near term. The effective diameter, calculated from the synchronized integrals of the blood flow velocity and the diameter curves, was significantly greater (p in the range 0.0001 to 0.0016) than the mean diameter. The difference tended to decrease with advancing gestational age and was more pronounced in the thoracic than in the abdominal aorta. The maximum error incurred by the use of nonsimultaneous measurements of blood flow velocity and vessel diameter when calculating volume blood flow was found to be less than 8% and thus probably of little practical importance.

Aorta, Thoracic↗

In vitro validation of Doppler indices using blood and water.

Using an in vitro flow model, volume flow and pressure were measured to compare calculated resistance with simultaneously measured continuous-wave Doppler indices during imposed changes in downstream resistance to pulsatile flow. With stepwise reductions in flow, the peak (S) and trough (D) points of the maximum shifted-frequency envelope fell in parallel in a linear fashion until D reached zero. Pressure remained constant, and the pressure waveform remained unchanged. As calculated resistance increased, resistance index (RI) and pulsatility index (PI) both increased in a linear fashion until the point at which D became zero. However, S/D ratio was not linear, and the slope increased as resistance increased. The results obtained from microspheres suspended in water and with heparinized sheep's blood were similar. The results indicate that, with reductions in flow at constant pressure in vitro, S/D ratio does not relate to calculated resistance in the same linear manner as PI and RI.

Animals↗

[Comparative studies on pulsatile and continuous flow during extracorporeal circulation. Effects on liver function and endocrine pancreas secretion].

The effects of pulsatile and nonpulsatile flow pattern on pancreas and liver blood flow were studied in nine dogs on cardiopulmonary bypass (CPB). Furthermore, plasma levels of glucose, insulin, glucagon, growth hormone, and cholinesterase were compared in 20 patients subjected to open heart surgery with either pulsatile or nonpulsatile perfusion. Impairment of liver and pancreas function was significantly greater at the end of CPB and 48 h afterwards with nonpulsatile flow as compared with the pulsatile flow pattern. A decrease of intestinal blood flow that was demonstrated in dogs subjected to nonpulsatile perfusion could at least in part be responsible for the difference in postoperative organ function observed in patients after CPB.

Animals↗

Portal vein pulsatility in normal and cirrhotic adults without cardiac disease.

The literature indicates that Doppler demonstration of pulsatile flow in the portal vein suggests heart disease, and that retrograde transsinusoidal transmission of atrial pulsations is the mechanism. We noninvasively investigated portal vein pulsatility (PVP) in normal subjects and in patients with cardiac and liver disease, and performed invasive studies in cirrhotic humans and normal pigs. We found that accentuated PVP occurred in some normal subjects and in some patients with cirrhosis, and that mechanisms other than transsinusoidal transmission of atrial pulsations contributed to PVP. Determinants of PVP may include pulsatile portal inflow, transmission of pulsations from the vena cava (IVC) and location of the Doppler sample volume relative to the IVC.

Adolescent↗

Evaluating pulsatile ocular blood flow analysis in normal and treated glaucomatous eyes.

PURPOSE: To evaluate pulsatile ocular blood flow (POBF) analysis in normal subjects and glaucoma patients by comparison of POBF measurements with functional (as determined by visual field [VF]) and structural (as determined by optical coherence tomography [OCT]) measures. DESIGN: Prospective, cross-sectional study. METHODS: Forty-one eyes of 24 consecutive glaucoma patients and 20 eyes of 10 healthy subjects were studied; POBF analysis was performed on all subjects at the same visit as VF testing and OCT retinal nerve fiber layer (NFL) thickness measurement. The mean results of normal and glaucomatous eyes were compared for each method. Correlation between measurements obtained with each modality and the discriminating power using receiver operator characteristic curves was tested. RESULTS: The mean POBF (standard deviation [SD]) in the normal group was 1,010.4 (292.8) microl/min and 989.3 (305.5) microl/min in the glaucoma group (P =.90). Significant differences between groups were found for VF mean deviation and pattern standard deviation (P =.02, P =.004, respectively) and OCT mean NFL thickness (P <.0001). No correlation was found between POBF parameters and intraocular pressure, VF, or OCT variables except for intraocular pressure in glaucoma group (r = -.43, P =.003). The area under the receiver operator characteristic curves was higher for VF indexes and OCT mean NFL thickness than POBF parameters for distinguishing between normal and glaucomatous eyes. CONCLUSIONS: The wide range of normal values and the low discriminating power of POBF between normal and glaucomatous eyes limits the clinical use of the device for glaucoma patients.

Aged↗

Calculation of the pulsatile ocular blood flow.

Based on reasonable assumptions, it is theoretically possible to determine the pulsatile ocular blood flow. The pertinent parameter is not the pulse amplitude but the steepest decay value of record (ie, the minimum of dV(t)/dt). Some advantages of developing the record in Fourier series are discussed. The importance of careful analysis of the recording system is stressed.

Blood Flow Velocity↗

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.

AIMS: To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS: 479 subjects underwent intraocular pressure measurements with the Goldmann applanation tonometer and the pulsatile ocular blood flow tonograph. Of these, 334 patients underwent additional measurement of central corneal thickness with an ultrasonic pachymeter and corneal curvature measurement with a keratometer. RESULTS: The intraocular pressure measurements obtained with both the Goldmann applanation tonometer and the pulsatile ocular blood flow tonograph varied with central corneal thickness and mean keratometric reading. Intraocular pressure measured using the Goldmann applanation tonometer increased by 0.027 mm Hg per micro m increase in central corneal thickness. Intraocular pressure measured using the pulsatile ocular blood flow tonograph increased by 0.048 mm Hg per micro m increase in central corneal thickness. For an increase of 1 mm of mean corneal curvature there was rise in intraocular pressure of 1.14 mm Hg measured by the Goldmann applanation tonometer and of 2.6 mm Hg measured by the pulsatile ocular blood flow tonograph. When compared to the Goldmann applanation tonometer, the pulsatile ocular blood flow tonograph underestimated at low intraocular pressure and overestimated at higher intraocular pressure. CONCLUSION: Central corneal thickness and corneal curvature affected measurements obtained with the pulsatile ocular blood flow tonograph more than they affected measurements obtained with the Goldmann applanation tonometer.

Adolescent↗