Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PERCHLORIC ACID”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Simultaneous determination of levodopa and 3-O-methyldopa in human plasma by liquid chromatography with electrochemical detection.

A simple and rapid assay is described for the simultaneous analysis of levodopa (l-DOPA) and 3-O-methyldopa (3-OMD) in human plasma samples, applying an ion-pair reversed-phase liquid chromatographic method with electrochemical detection, designed for clinical trials performed to study the effect of peripheral catechol-O-methyltransferase inhibitors on the metabolism of l-DOPA. After protein precipitation of 100 microl plasma sample aliquots with perchloric acid, the analytes are directly injected, separated within 10 min and simultaneously quantified down to 20 ng/ml by an electrochemical detector equipped with a dual-electrode system operating in redox mode eliminating effectively potential endogenous and exogenous interferences. The intra-assay precision for l-DOPA and 3-OMD was 1.34-6.54 and 3.90-5.50%, whereas the inter-assay precision was 2.09-7.69 and 4.16-9.90%, respectively. The recoveries were close to 90% for l-DOPA and almost 100% for 3-OMD. Satisfactory storage stability was achieved for up to 16 weeks at -70 degrees C by stabilizing plasma samples with antioxidants.

Calibration↗

Determination of lamivudine in plasma, amniotic fluid, and rat tissues by liquid chromatography.

An HPLC method for the quantification of lamivudine (3TC) in rat plasma, amniotic fluid, placental and fetal tissues has been developed, validated and applied to the study of the placental transport of this drug in the pregnant rat. Placental and fetal tissues were processed using liquid-liquid extraction enhanced by salting out the sample using a saturated solution of ammonium sulfate. Plasma and amniotic fluid samples were processed by protein precipitation using 2 M perchloric acid. Reverse phase chromatography was performed using a phenyl column (5 microm, 150 mm x 2 mm i.d.) under a flow rate of 0.2 ml/min. The mobile phase consisted of 5% methanol in 20 mM dibasic phosphate buffer (pH 6). The method was validated over the range from 0.1 to 50 microg/ml for plasma and amniotic fluid and 0.2-50 microg/ml for the placental and fetal tissues.

Amniotic Fluid↗

Liquid chromatographic determination of amodiaquine in human plasma.

A normal-phase high-performance liquid chromatographic method using dichloromethane- methanol-1M perchloric acid (100:10:0.9, v/v/v) at a flow rate of 1.0 ml min(-1) on a LiChrospher Si column with UV (254 nm) detection has been developed for the determination of amodiaquine and its metabolites desethyl amodiaquine and bisdesethyl amodiaquine in plasma. The limit of quantification was 5 ng ml(-1). Mean within-day and day-to-day coefficients of variation (CV) were 4.10 and 6.27% for amodiaquine, 3.43 and 4.80% for desethyl amodiaquine and 3.53 and 5.23% for bisdesethyl amodiaquine, respectively. Mean extraction recovery of amodiaquine, desethyl amodiaquine and bisdesethyl amodiaquine from plasma were 82.48, 74.50 and 69.65%, respectively. Chloroquine and its metabolite desethyl chloroquine, quinine, sulfadoxine and primaquine do not interfere in the detection of amodiaquine, desethyl amodiaquine and bisdesethyl amodiaquine in plasma.

Amodiaquine↗

Validated liquid chromatographic determination of 5-fluorouracil in human plasma.

A sensitive, reproducible, selective and accurate high performance liquid chromatographic (HPLC) method for the quantitative determination of 5-flurorouracil in plasma has been developed and validated using isocratic elution and UV detection. The method provides a selective quantifications of 5-flurorouracil without any interference of the endogenous uracil. The assay is performed after a double extraction of 5-flurorouracil and thymine (internal standard) from human plasma using ethyl acetate. The drug and the internal standard were eluted from a Genesis C(18) analytical column at ambient temperature with mobile phase consisting of methanol:water (10:90, v/v) adjusted to pH 3.2 with perchloric acid at a flow rate of 1.0 ml/min. The effluent was monitored with an ultraviolet detector at 260 nm. Quantification was achieved by the measurement of the peak-height ratios and the limit of quantification for 5-flurorouracil in plasma was 30 ng/ml. The retention times for 5-flurorouracil, uracil, and thymine were 4.5, 6.0, and 9.0, respectively. The intra-day coefficient of variation (CV) ranged from 1.35 to 4.53% at three different concentrations and the inter-day CVs varied from 1.29 to 4.98%. The relative and absolute recoveries varied from 96 to 101%. Stability tests showed that 5-flurorouracil is stable for at least 72 h in plasma after freezing. The simple method may permit the assessment of 5-flurorouracil plasma concentrations for pharmacokinetic studies in combination with clinical trials.

Antimetabolites, Antineoplastic↗

Simultaneous determination of haloperidol and bromperidol and their reduced metabolites by liquid-liquid extraction and automated column-switching high-performance liquid chromatography.

This study describes a new simultaneous determination of haloperidol and bromperidol and their reduced metabolites by modification of automated column-switching high-performance liquid chromatography. The test compounds were extracted from 1ml of plasma using chloroform-hexane (30:70 (v/v)), and the extract was injected into a hydrophilic metaacrylate polymer column for clean-up and a C(18) analytical column for separation. The mobile phases consisted of phosphate buffer (0.02M, pH 4.6), perchloric acid (60%) and acetonitrile (54:1:45 (v/v)) and was delivered at a flow-rate of 0.6ml/min. The peak was detected using a UV detector set at 215nm. The method was validated for the concentration range 1-100ng/ml, and good linearity (r >0.999) was confirmed. Intra-day coefficient variations (CVs) for haloperidol, reduced haloperidol, bromperidol and reduced bromperidol were less than 2.5, 3.1, 2.4 and 2.5%, respectively. Inter-day CVs for corresponding compounds were 3.9, 5.1, 2.6 and 4.4%, respectively. Relative errors ranged from -5 to 10% and mean recoveries were 96-100%. The limit of quantification was 1.0ng/m for each compound. This method shows good specificity with respect to commonly prescribed psychotropic drugs, and it could be successfully applied for pharmacokinetic studies and therapeutic drug monitoring, particularly in patients receiving both haloperidol and bromperidol.

Antipsychotic Agents↗

Determination of trimethoprim in low-volume human plasma by liquid chromatography.

Trimethoprim is an anti-infective agent used in the treatment of urinary and respiratory tract infections and mild to moderate pneumocystis carinii pneumonia. Trimethoprim is also a selective in vitro inhibitor of cytochrome P450 2C8 and may have utility as an in vivo inhibitor of this enzyme. A simplified high performance liquid chromatography (HPLC) method was developed to determine trimethoprim in human plasma. Samples are processed by protein precipitation with perchloric acid and chromatographic separation is achieved on a Synergi Polar-RP column (4 micron, 150 mm x 4.6 mm) using a mobile phase consisting of 50 mM ammonium formate-acetonitrile-methanol (pH=3.0; 90:6:4 (v/v/v)). Detection is monitored at 280 nm. Intra- and inter-day precision ranged from 1.1 to 1.9 and 0.9 to 4.1%, respectively. The assay is simple, economical, precise, and is directly applicable to human studies involving steady state trimethoprim pharmacokinetics.

Anti-Bacterial Agents↗

Automated solid-phase extraction method for the determination of piperaquine in capillary blood applied onto sampling paper by liquid chromatography.

A bioanalytical method for the determination of piperaquine in 100 microL blood applied onto sampling paper, by solid-phase extraction and liquid chromatography, has been developed and validated. Blood spots were cut into small pieces prior to addition of 0.3M perchloric acid, acetonitrile and phosphate buffer containing an internal standard. The liquid phase was loaded onto a mixed phase cation-exchange (MPC) solid-phase extraction column. Piperaquine and the internal standard were analysed by liquid chromatography and separated on a Chromolith Performance (100 mm x 4.6 mm) column with acetonitrile:phosphate buffer pH 2.5, I = 0.1 (8:92, v/v) at the flow of 3.5 mL/min. The UV detection was performed at 345 nm. The intra-assay precision was 12.0% at 0.150 microM, 7.3% at 1.25 microM and 7.3% at 2.25 microM. The inter-assay precision was 1.8% at 0.150 microM, 5.2% at 1.25 microM and 2.8% at 2.25 microM. The lower limit of quantification (LLOQ) was determined to 0.050 microM where the precision was 14.7%.

Antimalarials↗

Rapid determination of loratadine in small volume plasma samples by high-performance liquid chromatography with fluorescence detection.

A simple and rapid high-performance liquid chromatographic method with fluorescence detection was developed for the determination of loratadine in small volume plasma samples. Liquid-liquid extraction of loratadine and diazepam (as internal standard) from plasma samples was performed with n-butyl alcohol/n-hexane (2:98, v/v) in alkaline condition followed by back-extraction into diluted perchloric acid. Chromatography was carried out using a C8 column (250 x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-20 mM sodium dihydrogen phosphate-triethylamine (43:57:0.02, v/v), pH 2.4. Analyses were run at a flow-rate of 1.0 ml/min at room temperature. The method was specific and sensitive with a quantitation limit of 0.62 ng/ml and a detection limit of 0.2 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery of loratadine from plasma was 84%, while the intra-and inter-day coefficient of variation and percent error values of the assay method were all less than 9.7%. Linearity was assessed in the range of 0.62-20 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method has been used to analyze several hundred human plasma samples for bioavailability studies.

Calibration↗

Sensitive determination of midazolam and 1'-hydroxymidazolam in plasma by liquid-liquid extraction and column-switching liquid chromatography with ultraviolet absorbance detection and its application for measuring CYP3A activity.

This manuscript described a new sensitive determination of midazolam and its metabolite 1'-hydroxymidazolam by automated column-switching high-performance liquid chromatography. The test compounds were extracted from 2 ml of plasma using chloroform-hexane (30:70, v/v) and the extract was injected into a column I (TSK-PW precolumn, 10 microm, 35 mm x 4.6 mm i.d.) for clean-up and column II (C18 STR ODS-II analytical column (5 microm, 150 mm x 4.6 mm i.d.) for separation. The mobile phase for separation consisted of phosphate buffer (0.02 M, pH 4.6), perchloric acid (60%) and acetonitrile (57.9:0.1:42, v/v/v) and was delivered at a flow-rate of 0.6 ml/min. The peak was detected using a UV detector set at 254 nm. The method was validated for the concentration range 0.3-100 ng/ml, and good linearity (r > 0.998) was confirmed. Intra- and inter-day coefficient variations for midazolam and 1'-hydroxymidazolam were less than 8.5 and 6.1%, respectively, at the concentrations of 0.5, 5 and 50 ng/ml for the test compounds. Relative errors ranged from -14 to 6% and mean recoveries were 78-85%. The limit of quantification was 0.5 ng/ml for each compound. This method was sensitive enough for pharmacokinetic studies measuring CYP3A activity in human volunteers following an intravenous (1 mg) and a single-oral administration (2 mg) of a subtherapeutic midazolam dose.

Adult↗

LC-MS/MS determination in rabbit plasma of the main photoproduct of RLP068/Cl, a cationic sensitizer proposed for photodynamic therapy (PDT) of microbial infections.

The clinical development of a sensitizer for photodynamic therapy (PDT) requires the structural identification of the photoproducts and their quantification in biological fluids and tissues. We describe the LC-MS identification of the most important photoproducts of a cationic phthalocyanine sensitizer (RLP068/Cl) and a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of the main photoproduct (the cationic phthalimide derivative 3-[(1,3-dioxo-2,3-dihydro-1H-isoindol-4-yl)oxy]-N,N,N-trimethylbenzenaminium chloride) in rabbit plasma. The tri-deuterated product was used as co-eluting internal standard. The cationic photoproduct was isolated from plasma samples by protein precipitation with perchloric acid in methanol (7%, v/v). HPLC step was performed on a Phenomenex Synergi Hydro-RP column (20 mm x 2.0 mm, 2 microm particles) with a mobile phase of 0.5% (v/v) aqueous TFA/methanol (85:15, v/v). Flow rate was 0.2 mL/min and 40 microL injection were performed. Run time was 10 min. Detection was achieved by means of a Bruker Esquire 3000+ ion trap mass spectrometer equipped with an ESI source working in positive mode. A multiple reaction monitoring method following the transitions 297.1 --> 282.1 for the analyte and 300.1 --> 282.1+285.1 for the internal standard was used. The analytical method was validated over the concentration range 0.46-91.2 ng/mL and lower limits of detection (LLOD) and quantification (LLOQ) respectively of 0.2 and 0.5 ng/mL were found.

Animals↗

Simple and cost-effective liquid chromatographic method for determination of pyrimethamine in whole blood samples dried on filter paper.

A cost-effective HPLC method for determination of pyrimethamine (PYR) in human whole blood samples dried on filter paper (Whatman) is reported. Trimethoprim (TMP) was used as an internal standard. Whole blood spiked with PYR was transferred (100 microl) onto filter paper and dried at room temperature. Capillary blood samples (100 microl) after ingestion of three tablets of sulfadoxine-pyrimethamine (SP) by one subject were also tested. PYR and an internal standard (IS) TMP were extracted into di-isopropyl ether as bases and then re-extracted with 150 microl mobile phase. A C-18 column was used and the mobile phase consisted of phosphate buffer (0.05 M, pH 5):acetonitrile:concentrated perchloric acid (750:300:2.5, v/v/v). The absorbances of PYR and IS were monitored at 270 nm. The limit of quantification was 40 ng/ml. The within- and between-assay coefficient of variations were <10% at the limit of quantification.

Antimalarials↗

Determination of thiamine and its phosphate esters in rat tissues analyzed as thiochromes on a RP-amide C16 column.

A new reversed-phase chromatographic method is described for the separation and quantification of thiamine (T), thiamine monophosphate (TMP) and diphosphate (TDP) in rat tissues. Sample extraction with perchloric acid (HClO(4)) was found more suitable than extraction with trichloroacetic acid (TCA), as regards convenience and background fluorescence. Derivatization of thiamine vitamers to thiochromes was optimized and complete separation of TDP and TMP thiochromes was obtained on a RP-amide C16 column in isocratic elution, with T thiochrome eluting in less than 10 min. The precision and the accuracy of the HPLC procedure were assessed: ranging from 0.5 to 7.7% for intra-day and from 2.0 to 9.4% for inter-day precision, a recovery average of 101% was determined (range 90-111%). Mean values of recovery for TDP, TMP or T were 91, 96 and 90% for liver extracts, respectively. Analysis of vitamers in tissues of rat submitted to 8 days thiamin deficiency, followed by a 14 days repletion, showed a significant reduction of TPP after 8 days of depletion in liver (-67%), brains (-50%), kidneys (-60%), followed by a complete recovery upon repletion.

Animals↗

Development and validation of an HPLC-UV method for determination of iohexol in human plasma.

An HPLC-UV analytical method for estimation of iohexol in human plasma was developed and validated. Protein precipitation and iohexol extraction from plasma (100 microl) was carried out by adding 800 microl perchloric acid (5%, v/v in water) containing iohexol related compound B as the internal standard followed by vortex mixing and centrifugation. The supernatant (90 microl) was then injected onto a microBondapak C(18) column (150 mm x 3.9 mm, 10 microm) maintained at 30 degrees C. The mobile phase comprised of various proportions of acetonitrile and water with a total run time of 12 min and the wavelength of the UV detector was set at 254 nm. The extraction recovery of iohexol from plasma was >95% and the calibration curve was linear (r(2)=0.99) over iohexol concentrations ranging from 10 to 750 microg/ml (n=8). The method had an accuracy of >92% and intra- and inter-day CV of <3.7% and <3.6%, respectively. The method reported is simple, reliable, precise, accurate and has the capability of being used for determination of iohexol in clinical settings.

Blood Chemical Analysis↗

Liquid chromatographic quantitation of the lactone and the total of lactone and carboxylate forms of 9-nitrocamptothecin in human plasma.

Simple and sensitive high-performance liquid chromatography (HPLC) assays were developed and validated for the quantitation of the investigational anticancer drug 9-nitrocamptothecin (9-NC) as the lactone form and as the total of the lactone(I) and carboxylate(II) forms in human plasma. For the assay of lactone form (9NC-lac), the analytical method involved a protein precipitation step with adding a mixture of cold acetonitril-chloroform (5:1 (v/v), -20 degrees C) to plasma sample that stabilized the pH-dependent conversion of I to II. After evaporation under gentle stream of nitrogen gas (40 degrees C) the dry extract was dissolved in mobile phase (pH 5.5). For determination of the total of the lactone and carboxylate forms of the drug (9NC-tot), plasma samples were deproteinated with cold acetonitril (-20 degrees C) acidified with perchloric acid (5%), which resulted in the conversion of the carboxylate into the lactone form. After centrifugation the upper solvent was evaporated (nitrogen, 40 degrees C) and the dry extract was dissolved in mobile phase (pH 3.5). All separations were performed on a RP-C(8) column, using a mixture of acetonitril-water as eluent (pH 3.5 for total form and pH 5.5 for lactone form) and UV detection. The presented assay was linear over a concentration range of 25-1500 ng/ml with lower limit of quantitation of 25 ng/ml for both 9NC-tot and 9NC-lac. Within-run and between-run precision was always less than 7.5% in the concentration range of interest. The reported assay method showed good characteristics of linearity, sensitivity, selectivity and precision allowing applying in pharmacokinetic studies.

Antineoplastic Agents↗

Determination of levetiracetam in human plasma with minimal sample pretreatment.

We here present a method for the routine quantification of the novel antiepileptic drug levetiracetam in human serum by HPLC-UV. The procedure is very easy, quick, inexpensive and rugged. The sample preparation consists only in the precipitation of serum proteins by perchloric acid and extraction of unpolar components by cyclohexane. The aqueous phase containing the analyte levetiracetam is injected onto a porous graphitic carbon analytical HPLC-column and separated by gradient elution with diluted phosphoric acid/acetonitrile. Detection is carried out at a wavelength of 205 nm. The calibration function is linear in the range of 1-75 microg/ml. The detection limit is 0.1 microg/ml. Using four quality control sample concentrations, the inter-day relative standard deviations (R.S.D.) are lower than 3% and the accuracies are better than 6%. The respective inter-day values are: R.S.D. < 4% and accuracies better than 2%. Frequently co-administered antiepileptic drugs do not interfere with the assay. The method has been successfully applied to patient samples.

Anticonvulsants↗

Determination of talinolol in human plasma using automated on-line solid phase extraction combined with atmospheric pressure chemical ionization tandem mass spectrometry.

A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.

Automation↗

Improved solid-phase extraction and HPLC measurement of torasemide and its important metabolites.

Torasemide is a "loop type" diuretic drug. For pharmacokinetic studies sensitive analytic methods are essential for authentic qualitative and quantitative information. A robust, selective and sensitive HPLC method is described for the simultaneous determination of torasemide, its major metabolite M5 and its active metabolites M1 and M3 and an internal standard within 17 min. Solid-phase extraction with C(2)-cartridges was used for the clean-up of plasma samples. The chromatographic separation was carried out on a CN-column with a mobile phase consisting of perchloric acid (0.02 M, pH 2.5)/acetonitrile (90/10, v/v)). The calibration range used reached from 20 to 1000 ng/ml for all analytes. Coefficients of variation were less than 10% at every calibration point for each analyte. Plasma concentrations in samples obtained from volunteers in the course of a clinical study could be reliably measured with this method. Median maximum concentrations in plasma after a 10mg oral dose during a 24h study interval were located at 1h for torasemide, 1h for M1 and 2h for M5. Concentrations between 2226 and <20 ng/ml for torasemide, between 159 and <20 ng/ml for M1 and between 420 and <20 ng/ml for M5 were observed.

Aryl Hydrocarbon Hydroxylases↗

Improvement and validation of an HPLC method for examining the effects of the MDR1 gene polymorphism on sparfloxacin pharmacokinetics.

A rapid, simple, accurate, and precise reverse-phase high-performance liquid chromatography (HPLC) method for measuring sparfloxacin in human serum was improved, validated, and applied to determine the influence of polymorphisms in MDR1 (exons 12, 21, and 26) gene on sparfloxacin pharmacokinetics. Sparfloxacin and an internal standard, ciprofloxacin, were extracted from human serum by protein precipitation with dilution and analyzed on a Luna C(18) 5-microm column in a mobile phase of acetonitrile-0.035 M perchloric acid (28:72, v/v, adjusted to pH 2.0 with 0.015 M triethylamine) and UV detection at 300 nm. This analysis was performed at three different laboratories using the same quality control (QC) samples. The chromatograms showed good resolution, sensitivity, and no interference by human serum. The method showed linear responses over a concentration range of 0.05-2 microg/ml, with correlation coefficients of greater than 0.999 at the three laboratories. Intra- and inter-day assay precision and accuracy fulfilled international requirements. The mean absolute recovery for human serum was 98.8+/-5.7%. Sparfloxacin in human serum was stable during storage and the assay procedure. The lower limit of quantification using 0.2 ml of serum was 0.05 microg/ml, which was sensitive enough for pharmacokinetic studies. This method was used to study the pharmacokinetics of sparfloxacin in human volunteers, following a single oral administration of sparfloxacin (100 mg) two tablets at three different laboratories. MDR1 polymorphisms did not significantly (P < 0.01) affect the pharmacokinetic parameters (AUC and C(max)) of sparfloxacin.

Anti-Bacterial Agents↗