Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Experimental demonstration of a laterally deformable optical nanoelectromechanical system grating transducer.

We experimentally demonstrate operation of a laterally deformable optical nanoelectromechanical system grating transducer. The device is fabricated in amorphous diamond with standard lithographic techniques. For small changes in the spacing of the subwavelength grating elements, lossy propagating resonant modes in the plane of the grating cause a large change in the optical reflection amplitude. An in-plane motion detection sensitivity of 160 fm/square root(Hz) was measured, exceeding that of any other optical microelectromechanical system transducer to our knowledge. Calculations predict that this sensitivity could be improved to better than 40 fm/square root(Hz) in future designs. In addition to having applications in the field of inertial sensors, this device could also be used as an optical modulator.

Journal Article↗

Fabrication of subwavelength structure for improvement in light-extraction efficiency of light-emitting devices using a self-assembled pattern of block copolymer.

A new fabrication method to improve the optical extraction efficiency of light-emitting devices is presented. The morphology of a self-assembled block copolymer was transferred to the surface of a compound semiconductor to achieve a subwavelength columnar structure. The optical extraction efficiency of the substrates with subwavelength columnar structures of 350 nm pillar height, 130 nm diameter, and 180 nm pitch, improved 2.2 times compared to unprocessed substrates. This method does not require expensive exposure lithography tools and is therefore suitable for conventional semiconductor processes.

Journal Article↗

Chapter 10: Cervical cancer screening using visualization techniques.

There is a resurgence of interest in the use of visual techniques to identify cervical intraepithelial neoplasia (CIN). These visual techniques can be divided into two general categories. One is the simple visual screening method, such as direct visual inspection (DVI), during which the cervix is visualized with either the naked eye or a low-power magnification device after the application of a solution of 3% to 5% acetic acid that is used as a chemical contrast agent to highlight regions of CIN. DVI has been evaluated in a number of large clinical trials and is considered by some to be a possible alternative to cervical cytology for primary cervical cancer screening in low-resource settings. The advantages of DVI compared with cervical cytology for these settings are that it is inexpensive, it does not require a laboratory infrastructure, and it provides an immediate result, allowing the use of "screen and treat" protocols. The major disadvantage of DVI is that it is relatively nonspecific and that its sensitivity is low compared with testing for human papillomavirus. The other category of visual techniques includes devices that use electro-optical sensors and light of specific wavelengths produced by lasers or specialized light sources to identify and localize regions of CIN on the cervix. Although these "high-technology" devices are not yet in routine clinical use, several groups and companies have such devices in clinical trials.

Clinical Competence↗

Continuous on-line optical absorbance recording of blood volume changes during hemodialysis.

Conventional techniques that measure blood volume changes during hemodialysis are invasive, hard to reproduce, and provide only intermittent evaluations. To overcome these drawbacks, we have developed an optoelectronic instrument that estimates intradialytic blood volume percentage changes by the optical absorbance of blood. This device is based on the absorption of light transmitted through blood, which is directly related to the hemoglobin concentration. A personal computer interfaced to the device provides a continuous on-line graphic display of the hemoglobin levels and the percentage changes in blood volume. The noninvasive measurement of dialysis blood volume changes by an optical method may be helpful in detecting the appearance of severe hypovolemia that can be dangerous in critically ill patients.

Absorption↗

Single-trocar-access thoracoscopy for fully optical controlled routine chest drainage: a technical report and feasibility study.

Complications of tube thoracostomy, e.g., organ lesions and malpositioned tubes, are not uncommon. To date, techniques for tube placement have been nonvisualized. The authors believe that a fully visualized penetration of the thoracic wall layers should help to avoid not only perforations and organ lesions but also functionally malpositioned tubes. This article describes a modified endoscopic device, allowing fully visualized and optically controlled access to the pleural cavity for routine chest tube placement. The results of the technical feasibility study for 28 human cadavers showed that it was possible to place the tube as desired. No organ lesions were present. The results suggest that this device and the technique could reduce the risk of complications. The handling of the device is easy and safe. The technique is minimally invasive. The authors' next goal is to prove the results in a clinical study.

Cadaver↗

A versatile intravital microscope design.

A new intravital microscope system with a versatile arrangement of optical elements and different photosensitive detection devices is described. The image formed by the microscope modified for telescopic imaging is transferred to an optical platform. Through an arrangement of beam splitters and mirrors, the image can be projected simultaneously into three of four different recording systems, including video- and photocameras and a velocity measuring system. In contrast to earlier approaches, the presented system simultaneously generates images on several devices. These images have the same orientation and field of view as that seen through the oculars. This allows the parallel application of different measuring techniques to a given area of the microcirculation.

Humans↗

[Application of spectral optical coherent tomography (SOCT) in ophthalmology].

The article describes spectral optical coherent tomography (SOCT) constructed by Medical Physics Group, Faculty of Physics, Astronomy and Informatics at Nicholas Copernicus University in Toruń (Poland). It presents the physical bases for the functioning of the constructed device and includes pictures of optical sections of various elements of the eyeball: an optic disc and the region of central fovea, a cornea and angle structures (trabecular meshwork). The article also discusses potential application of SOCT in ophthalmic diagnosis of anterior and posterior segments of the eye.

Eye Diseases↗

Cross-correlation of optical microcavity biosensor response with immobilized enzyme activity. Insights into biosensor sensitivity.

Porous silicon multilayer structures have remarkable optical and morphological properties that can be exploited for biosensing. In particular, a high internal surface area (>100 m(2)/cm(3)) and a linear response profile to changes in the dielectric environment enable fabrication of sensitive devices and a straightforward quantitation of the optical response. These essential operating characteristics are illustrated for p+ mesoporous silicon (pore diameter 15-20 nm) optical microcavities. A series of devices were prepared to permit the immobilization of glutathione-S-transferase ( approximately 50 kDa) within the porous matrix. Enzyme activity was exploited as an indirect means to quantitate the amount of protein immobilized. Activity was positively correlated with the optical sensor response. However, at high enzyme load the activity becomes nonlinear while the microcavity response remains linear. These data were used to determine the transduction limit (minimum amount of protein required to transduce an optical response), which is reported as areal mass sensitivity ranging between 50 and 250 pg/mm(2). This value is considered in context with the dynamic range of the bulk sensitivity, defined as the magnitude of the wavelength shift per refractive index unit, which was measured as a function of microcavity design parameters. This work has uncovered key parameters that can be tuned to improve the detection limit of this sensor modality. Because of the ever increasing number of emerging new biosensor technologies, defining sensor detection limits has become an ambiguous topic and a need exists to standardize measurements and sensitivity units. For chip-based devices, it seems appropriate to report sensitivity in terms of the minimum number of grams of bound target per surface area.

Biosensing Techniques↗

Computer modelling of mixed metal fluorides for optical applications.

This paper describes a new computational method for predicting the optical behaviour of doped inorganic materials. There is considerable interest in using inorganic materials in photonic devices, and in many cases, the optical properties of these materials depend on doping by ions such as those from the rare earth series. Among the inorganic materials of interest are the mixed metal fluorides (e.g. BaLiF(3), BaY(2)F(8), YLiF(4), LiCaAlF(6), LiSrAlF(6)), doped with trivalent rare earth ions. The paper describes the use of Mott-Littleton calculations to determine the optimum location for dopant ions, followed by crystal field calculations which make direct use of the output of the Mott-Littleton calculations to calculate the optical properties of the dopant ion taking into account its symmetry and the positions of the surrounding ions, including any vacancies or interstitial ions present by virtue of charge compensation. It is then possible to predict whether a given dopant ion at a particular site in a material will have favourable optical properties.

Journal Article↗

Ultrasonic bone curettage for optic canal unroofing and anterior clinoidectomy. Technical note.

Extradural unroofing of the optic canal and subsequent mobilization of the optic nerve is a useful technique in the surgical treatment of parasellar tumors; however, the drilling procedure itself is associated with the risk of optic nerve damage. A safer technique would certainly be beneficial. The ultrasonic bone curette is a device developed in Japan for safer bone removal. Its use in intradural anterior clinoidectomy and opening of the internal auditory meatus has been reported before. In this article the authors describe their experience in using this device for extradural unroofing of the optic canal in patients with parasellar tumors. Between March 2002 and November 2004, the aforementioned technique was used in the treatment of eight patients with parasellar tumors. After undertaking a frontotemporal craniotomy and orbital osteotomy, an ultrasonic bone curette was used to unroof the optic canal via an epidural approach; in five cases anterior clinoidectomy was added subsequently. Using an ultrasonic bone curette, unroofing of the optic canal was completed safely and required much less expertise than that required for standard drilling. The mortality and major morbidity rates were 0%. The visual function outcome was satisfactory, with the overall visual status improving in all seven patients in whom this symptom was present preoperatively. The ultrasonic bone curette makes the unroofing of the optic canal safer and easier, possibly improving the visual outcome of patients undergoing surgery for parasellar tumors.

Craniotomy↗

Optical grating coupler biosensors.

By incorporating a grating in a planar optical waveguide one creates a device with which the spectrum of guided lightmodes can he measured. When the surface of the waveguide is exposed to different solutions, the peaks in the spectrum shift due to molecular interactions with the surface. Optical waveguide lightmode spectroscopy (OWLS) is a highly sensitive technique that is capable of real-time monitoring of these interactions. Since this integrated optical method is based on the measurement of the polarizability density (i.e., refractive index) in the vicinity of the waveguide surface, radioactive, fluorescent or other kinds of labeling are not required. In addition, measurement of at least two guided modes enables the absolute mass of adsorbed molecules to be determined. In this article, the technique will be described in some detail, and applications from different areas will be discussed. Selected examples will be presented to demonstrate how monitoring the modification of different metal oxides with polymers and the response of the coated oxides to biofluids help in the design of novel biomaterials; how OWLS is useful for accurate bioaffinity sensing, which is a key issue in the development of new drugs; and how the quantitative study of protein-DNA/RNA and cell surface interactions can enhance the understanding of processes in molecular and cellular biology.

Adsorption↗

The effect of photomask resolution on separation efficiency on microfabricated devices.

Separation quality on glass microfluidic devices fabricated from photomasks of different optical resolutions was compared by measuring the dispersion (apparent diffusion) coefficients of a set of standard compounds separated on these devices. Currently, the channel manifolds of most microfluidic devices are patterned using chrome photomasks. A much cheaper, more robust alternative to chrome photomasks are laser photoplotted masks. The primary disadvantage to using laser photoplots is that the optical resolution of these masks is not as high as that of chrome masks, and this feature increases the side-wall roughness of etched channel manifolds patterned using such masks. The increased wall roughness may affect the fluid flow within the channels and, therefore, the separation quality. To determine the effect of increased sidewall channel roughness, microchip channel manifolds were patterned in soda lime glass using a chrome photomask and laser photoplots printed at resolutions of 620, 1240, 3100 and 6200 dots per centimetre (dpc). Separations were performed on these devices using dilute solutions of fluorescently labeled amino acids. The peak variances of the amino acids were calculated at increasing distances down the separation channel and plotted as a function of migration time. From this plot, dispersion coefficients of the analytes were measured. This allowed for a reliable, relatively easy, direct separation analysis among microchips fabricated from the various photomasks. After multiple separations using microchips fabricated from each resolution mask, we found that the change in sidewall surface roughness did not significantly affect the dispersion coefficients measured, and thus the separation quality. The lower mask resolution limit, rather, was governed by the fidelity to which the mask could capture the original CAD design.

Journal Article↗

A trap-and-release integrated microfluidic system for dynamic microarray applications.

Dynamic microarrays hold great promise for advancing research in proteomics, diagnostics and drug discovery. However, this potential has yet to be fully realized due to the lack of reliable multifunctional platforms to transport and immobilize particles, infuse reagents, observe the reaction, and retrieve selected particles. We achieved all these functions in a single integrated device through the combination of hydrodynamic and optical approaches. Hydrodynamic forces allow simultaneous transportation and immobilization of large number of particles, whereas optical-based microbubble technique for bead retrieval gives dexterity in handling individual particles without complicated circuitry. Based on the criterion derived in this paper, the device was designed, and fabricated using standard photolithography and soft lithography methods. We examined the dynamics of bubble formation and dissipation in the device, and parametric studies revealed that higher power settings at short intervals were more efficient than low power settings at longer intervals for bead retrieval. We also demonstrated the capabilities of our device and its potential as a tool for screening methods such as the "one-bead-one-compound" (OBOC) combinatorial library method. Although both approaches, hydrodynamic confinement and optical-based microbubbles, are presented in one device, they can also be separately used for other applications in microchip devices.

Journal Article↗

Vertical-cavity semiconductor devices for fluorescence spectroscopy in biochips and microfluidic platforms.

This paper describes the properties of vertical-cavity semiconductor devices designed to emit light when driven in forward bias mode and detect optical radiation at wavelengths longer than that of emission when driven in reverse bias mode. The study of this type of devices is motivated by the miniaturization and integration into a single unit of the three functions that a microfluorimeter has to perform, optical pumping, optical detection, and optical filtering of weak light sources. The devices produced can generate fluorescence with a low output power since their emission wavelength can be tuned with that of maximum absorption of the fluorescent dye. We demonstrate also that they can detect low power fluorescence generated in a small volume of concentrated solution of a commercial dye. These devices can find useful application in microanalytical systems such as microfluidic devices or optical biochips.

Biosensing Techniques↗

Terahertz all-optical modulation in a silicon-polymer hybrid system.

Although gigahertz-scale free-carrier modulators have been demonstrated in silicon, intensity modulators operating at terahertz speeds have not been reported because of silicon's weak ultrafast nonlinearity. We have demonstrated intensity modulation of light with light in a silicon-polymer waveguide device, based on the all-optical Kerr effect-the ultrafast effect used in four-wave mixing. Direct measurements of time-domain intensity modulation are made at speeds of 10 GHz. We showed experimentally that the mechanism of this modulation is ultrafast through spectral measurements, and that intensity modulation at frequencies in excess of 1 THz can be obtained. By integrating optical polymers through evanescent coupling to silicon waveguides, we greatly increase the effective nonlinearity of the waveguide, allowing operation at continuous-wave power levels compatible with telecommunication systems. These devices are a first step in the development of large-scale integrated ultrafast optical logic in silicon, and are two orders of magnitude faster than previously reported silicon devices.

Journal Article↗

Experimental targeting and control of spatiotemporal chaos in nonlinear optics.

We demonstrate targeting and control over spatiotemporal chaos in an optical feedback loop experiment. Different stationary target patterns are stabilized in real time by means of a two dimensional space extended perturbation field driven by an interfaced computer and applied in real space to a liquid crystal display device inserted within a control optical loop. The flexibility of the system in switching between different target patterns is also demonstrated.

Journal Article↗

Design and fabrication of diffractive optical elements by use of gray-scale photolithography.

Diffractive optical elements (DOEs) are key components in the miniaturization of optical systems because of their planarity and extreme thinness. We demonstrate the fabrication of DOEs by use of gray-scale photolithography with a high-energy-beam sensitive glass photomask. We obtained DOE lenses with continuous phase profiles as small as 800 microm in diameter and 5.9 microm in the outermost grating pitch by selecting a suitable optical density for each height level and optimizing the process variables. Microlenses patterned with eight levels and replicated by UV embossing with the polymer master mold showed a diffraction efficiency of 81.5%, which was sufficiently high for the devices to be used as optical pickups. The effects of deviations in diffraction efficiency between the DOE height and profile design were analyzed.

Journal Article↗

Use of the balloon dissector in minimally invasive aesthetic and reconstructive surgery.

The use of minimally invasive surgery continues to evolve in all fields of surgery with new developments in techniques and instrumentation. One instrument that has evolved and become useful in the field of plastic surgery is the balloon dissector. The purpose of this paper is to examine the role of the balloon dissector in minimally invasive aesthetic and reconstructive plastic surgery. We define the concept of the fascial cleft-the loose areolar space between fascial linings. In addition, the balloon dissector and its use is described. The optical cavity created by the balloon dissector device is discussed, along with the two techniques used to maintain the optical cavity, and manual retraction and carbon dioxide insufflation. The application of the balloon dissector in various regions of the body is discussed along with its use in free tissue transfers. Three patients are presented to illustrate the application of the balloon dissector.

Adult↗