Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Needlestick Injuries”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Hepatitis C in a ward for cystic fibrosis and diabetic patients: possible transmission by spring-loaded finger-stick devices for self-monitoring of capillary blood glucose.

OBJECTIVE: To identify the routes of transmission in a nosocomial outbreak of hepatitis C virus (HCV) infection. DESIGN: Epidemiological investigation, including screening for HCV of hospitalized patients, and a retrospective cohort study, review of hygiene and medical practices, and molecular comparison of HCV isolates. SETTING: A specialized care unit for cystic fibrosis (CF) and diabetic patients at an acute-care facility in the south of France. RESULTS: Of the 57 CF patients (age in 1995: 2-28 years), 38 (66.7%) were tested and 22 (57.9%) were anti-HCV positive. Eight (50%) of 16 patients with anti-HCV antibody tested by polymerase chain reaction were viremic. No patients had received blood products or had any history of intravenous drug use. All 18 (100%) patients with CF who had ever undergone self-monitoring of capillary blood glucose in the unit were anti-HCV positive, compared to 4 (20%) of 20 who had not (relative risk, 5.0; 95% confidence interval, 2.1-12.0). Seventy (39.5%) of the patients with diabetes were screened for anti-HCV; 12 (18.8%) tested positive, with 3 (25%) positive for HCV-RNA. Patients with diabetes had routine capillary blood glucose monitoring while hospitalized and shared with CF patients the same spring-triggered devices for capillary blood glucose monitoring. The disposable platform of the devices was not changed between patient use. All HCV isolates belonged to the type 1, subtype b, and phylogenetic analysis showed a close homology by sequencing of NS5b and E2/HVR regions. CONCLUSION: As reported earlier for the hepatitis B virus, shared spring-triggered devices for capillary blood glucose monitoring by finger puncture may transmit HCV. Strict application of Standard Precautions procedures is warranted in any healthcare setting.

Adolescent↗

Nosocomial transmission of hepatitis B virus infection among residents with diabetes in a skilled nursing facility.

OBJECTIVE: To identify exposures associated with acute hepatitis B virus (HBV) infection among residents with diabetes in a skilled nursing facility. DESIGN: Residents from Unit 3 and other skilled nursing facility residents with diabetes were tested for serologic evidence of HBV infection. Two retrospective cohort studies were conducted. Potential routes of HBV transmission were evaluated by statistical comparison of attack rates. SETTING: A 269-bed skilled nursing facility. PARTICIPANTS: All skilled nursing facility residents with diabetes and skilled nursing facility residents who lived on the same unit as the index case (Unit 3) for some time during the case's incubation period. RESULTS: All 5 residents with acute HBV infection had diabetes and resided in Unit 3. The attack rate among the 12 patients with diabetes in Unit 3 was 42%, compared with 0% among 43 patients without diabetes (relative risk, 37.2; 95% confidence interval, 4.7 to infinity). Acutely infected patients with diabetes received more morning insulin doses (P = .05), and more insulin doses (P = .03) and finger sticks (P = .02) on Wednesdays than did noninfected patients with diabetes. Two chronically infected patients with diabetes in Unit 3 were positive for hepatitis B e antigen and regularly received daily insulin and finger sticks. Of the 4 acute and 3 chronically infected residents from whom HBV DNA was amplified, all were genotype F and had an identical 678-bp S region sequence. Although no component of the lancets or injection devices was shared among residents, opportunities for HBV contamination of diabetes care supplies were identified. CONCLUSIONS: Contamination of diabetes care supplies resulted in resident-to-resident transmission of HBV. In any setting in which diabetes care is performed, staff need to be educated regarding appropriate infection control practices.

Acute Disease↗

Occupational risk of blood-borne viruses in healthcare workers: a 5-year surveillance program.

OBJECTIVE: This study presents the results of a 5-year surveillance program involving the prospective follow-up of healthcare workers (HCWs) in the Veneto region of Italy exposed to blood-borne viruses. DESIGN: All HCWs who reported an occupational exposure to blood-borne infection joined the surveillance program. Both HCWs and patients were tested for viral markers (hepatitis B surface antigen [HBsAg], antibody to hepatitis B surface antigen [anti-HBs], antibody to hepatitis B core antigen [anti-HBc], antibody to hepatitis C virus [anti-HCV], HCV RNA, and antibody to human immunodeficiency virus [HIV]) and had these markers plus transaminases assayed at 3, 6, and 12 months and then yearly thereafter. Moreover, a program of hepatitis B virus (HBV) prophylaxis was offered to those whose anti-HBs levels were less than 10 IU/mL. PARTICIPANTS: Two hundred forty-five HCWs (156 women and 89 men) with a mean age of 37 (+/- 10) years who reported occupational exposure during the 5-year period. RESULTS: At the time of exposure, 1 HCW was positive for HBsAg (0.4%) and 2 were positive for HCV RNA (0.8%). Among the patients involved, 28 (11.4%) were positive for HBsAg, 68 (27.8%) were positive for HCV RNA, 6 (2.4%) were positive for HIV, and 147 (60.0%) were negative for all viral markers (4 patients were positive for both HCV and HIV). During the follow-up period after exposure (mean, 2.7 [+/- 1.6] years), there was no increase in transaminases or seroconversions to any of the viral markers. CONCLUSION: Our accurate postexposure follow-up revealed a lack of transmission of HBV, HCV, and HIV.

Adult↗

Injection practices in Romania: progress and challenges.

OBJECTIVE: To identify breaks in infection control practices that might put Romanians at risk for transmission of hepatitis B virus (HBV) from injections. METHODS: A standardized questionnaire was administered to a systematic sample of the 1,906 nurses in Vâlcea District, Romania, to collect information on their knowledge, attitudes, and practices regarding injection administration and universal precautions. RESULTS: Of the 180 nurses interviewed, 91% (95% confidence interval [CI95], 86% to 95%) reported having attended training for universal precautions; 58% (CI95, 49% to 67%) accurately reported that HBV remains infectious for at least 1 week in the environment; and 4% (CI95, 2% to 8%) knew that HBV is transmitted more efficiently than HIV through percutaneous exposures. No nurses reported reusing syringes or needles on different patients, but 4 (2%; CI, 1% to 6%) would reuse a syringe and 3 (2%; CI95, 0% to 5%) would reuse a needle on the same patient in an emergency. Fifty-three percent (CI95, 44% to 61%) of nurses reported having a dedicated area for the preparation of injectable medications separate from where blood-contaminated items were handled. Shortages of infection control supplies were common. CONCLUSIONS: Although nurses in Vâlcea do not report reusing injection equipment without sterilization, other unsafe practices occur that may facilitate HBV transmission through injections, including preparing injectable medications in areas potentially contaminated with blood. Inadequate knowledge of blood-borne pathogen transmission and shortages of infection control supplies may contribute to these unsafe practices. Addressing these deficits could improve injection safety in Romania.

Adult↗

Factors promoting consistent adherence to safe needle precautions among hospital workers.

OBJECTIVE: To examine organizational factors and occupational characteristics associated with adherence to occupational safety guidelines recommending never recapping needles. DESIGN: Mail surveys were conducted with healthcare workers (HCWs) and infection control professionals (ICPs). SETTING: The surveys were conducted at all non-federal general hospitals in Iowa, except one tertiary-care hospital. Survey data were linked to annual survey data of the American Hospital Association (AHA). PARTICIPANTS: HCWs were sampled from statewide rosters of physicians, nurses, and laboratory workers in Iowa. Eligible HCWs worked in a setting and position in which they were likely to routinely handle needles. ICPs at all hospitals in the state were surveyed. RESULTS: Ninety-nine ICPs responded (79% response rate). AHA data were available for all variables from 84 (85%) of the hospitals. Analyses were based on 1,454 HCWs who identified one of these hospitals as their primary hospital (70% response rate). Analyses were conducted using multiple logistic regression. Positive predictors of consistent adherence included infection control personnel hours per full-time-equivalent employee (odds ratio [OR], 1.03), frequency of standard precautions education (OR, 1.11), facilities providing personal protective equipment (OR, 1.82), facilities using needleless intravenous systems (OR, 1.42), and management support for safety (OR, 1.05). Negative predictors were use of "blood and body fluid precautions" isolation category (OR, 0.74) and increased job demands (OR, 0.90). CONCLUSION: Healthcare organizations can improve staff safety by investing wisely in educational programs regarding approaches to minimize these risks, providing protective equipment, and eliminating the use of blood and body fluid precautions as an isolation policy.

Equipment Design↗

Efficacy of glove combinations in reducing cell culture infection after glove puncture with needles contaminated with human immunodeficiency virus type 1.

OBJECTIVE: To study the effect of various latex and treated glove combinations in reducing the frequency of human immunodeficiency virus (HIV) infection of tissue culture cells after puncture by surgical needles contaminated with infectious human immunodeficiency virus type 1 (HIV-1). DESIGN: One, two, or three layers of sterile latex glove material, or two latex layers with intermediate cotton or Kevlar (with or without the virucidal compound nonoxynol-9) were used to cover 24-well cell culture dishes containing MT2 cells in cell culture medium. Surgical needles wet with cell culture medium containing HIV-1 (HTLV IIIA strain) were passed through the glove materials into the culture medium in the wells of the culture dishes. The culture medium in each well was then assayed biweekly for HIV-1 p24 antigen as a test for infection of cells in the well. RESULTS: The rate of HIV-1 infection of cell cultures after glove puncture was greater than 90% with a single latex surgical glove barrier, 23% to 60% with double or triple layers of latex gloves, less than 8% with an intermediate cotton glove impregnated with 4% nonoxynol-9, 6% with an intermediate Kevlar glove, and 0% with an intermediate Kevlar glove impregnated with nonoxynol-9. CONCLUSIONS: An intermediate glove of Kevlar or of Kevlar or cotton impregnated with virucidal compound nonoxynol-9 between standard latex gloves may improve surgical glove safety, compared with latex gloves alone with respect to needlestick transmission of HIV-1. The experimental model used may permit rapid investigation of other glove systems as barriers to the transfer of infectious agents through gloves by needlestick.

Gloves, Surgical↗