The use of a new continuous wireless cardiorespiratory telemonitoring system by elderly patients at home.

The diagnosis and management of increasing numbers of patients with chronic diseases in the community require new technologies and strategies of care. We have used a new wireless cardiorespiratory telemonitoring system to monitor 14 elderly patients with a variety of chronic diseases at home. The electrocardiogram (ECG), heart rate and variability, and breathing were recorded on two separate occasions for 24 h. There was no difference in the data recorded when a research nurse applied the monitoring system and when the patients applied it themselves. The ECG and heart rate were recorded for 98% of the monitored time, and the frequency and periodicities of breathing were recorded for 74% and 61% of sleep and rest time by visual and automatic analysis, respectively. The results show that 24 h activity and cardiorespiratory telemonitoring can be performed by elderly patients at home. Significant unsuspected abnormalities of breathing and heart rhythm, amenable to treatment, were also detected.

Aged↗

A data-logging system to monitor bone fracture movement continuously.

A compact system is presented, which can continuously monitor the occurrence of fracture site movement in patients with tibial shaft fractures treated with an Orthofix external fixator allowing limited axial movement. The system comprises a microswitch and data logger board, which are both attached to the fixator. Each time the switch is closed by the movement of the fixator, the data logger records it as an event. The number of events per half hour is stored to the board's memory. The data logger can record the frequency of movement for at least a four-week period, at which time, the data can be transferred to a computer via a serial link. The system has been proven in a limited patient trial. The results highlight the variation in patient mobility. The significance of continuously monitoring the fracture site movement during the healing period is discussed.

Biomedical Engineering↗

Automatic systems for monitoring vinyl chloride in working atmospheres.

During the past two years, Union Carbide Corporation (UCC) has developed completely automatic systems for monitoring 0-25 ppm vinyl chloride monomer (VCM) in working atmospheres and for processing the data obtained. Each system includes a process gas chromatograph, a sampling system capable of monitoring up to 19 points and data processing equipment. The data systems compute and print out statistical summaries on shift, daily and monthly bases and estimate the maximum exposure to VCM for each job. These systems are now essential operating tools at several UCC production units.

Air↗

Hypoglycemia warning signal and glucose sensors: requirements and concepts.

Hypoglycemia is the most feared side effect of diabetes therapy with blood glucose-lowering agents. The fear of hypoglycemia often contributes to poor metabolic control of patients with diabetes. Therefore, integration of a hypoglycemia warning signal into continuous glucose monitoring systems represents an important additional help for patients with diabetes. The warning signal can be triggered at a preset level based on the current glucose values (as provided with the presently available glucose monitoring systems) or on prospective trend analysis offering the possibility to predict the risk of a hypoglycemic event in an anticipatory manner. Using the approach of a "Finite State Machine," such a more advanced warning system can completely be described as a finite collection of four states and possible transitions in-between. Most of the currently available glucose monitoring systems measure glucose in the interstitial fluid (ISF) of the dermal or subcutaneous tissue but are calibrated to blood glucose levels. This requires a number of factors to be taken into account: precision and accuracy of the glucose measurements, physiological and physical lag time, and calibration of the glucose monitoring system. From our point of view, the analytical performance of the system should be such that the majority of all hypoglycemic episodes are correctly diagnosed (>75%). Inconsistent findings regarding physiological discrepancies between blood and ISF glucose, which usually are described as a physiological lag time, range from some seconds up to 15 min. They can be observed especially during dynamic blood glucose changes (>3 mg/dL/min) and may represent major challenges for the development of a reliable hypoglycemia warning signal. In addition to possible physiological time lags, device-inherent physical lag times must be considered when selecting the threshold for the warning signal. Despite these problems, most probably all patients with diabetes who are treated with blood glucose-lowering agents will benefit from such a system since their safety and quality of life can be greatly improved, including an optimized metabolic control and lowered diabetes-related mortality. The benefit will be greatest for patients with hypoglycemia unawareness or impaired perception of hypoglycemic symptoms. The risks related to the use of a hypoglycemia warning signal seem to be low if certain precautionary measures are taken. In any case, additional clinical-experimental studies in healthy subjects as well as long-term clinical studies in diabetic patients are necessary to further evaluate the efficacy, benefits, and risks of different hypoglycemia warning concepts implemented in the different continuous glucose monitoring systems.

Biosensing Techniques↗

Fitts' principles still applicable: computer monitoring of fighter aircraft emergencies.

When examining the impact of automation in the cockpit, a careful distinction must be drawn between the role of a multi-crew civilian aircraft and a single-seat military aircraft. For the former, there are some concerns that automation can have a negative impact on the crew by reducing their proficiency. However, for a single-seat military aircraft on an attack mission, the role of automation is not only helpful to the pilot now but in the future may be necessary to achieve mission success. These distinctions must constantly be brought to mind in explaining the concepts of Fitts' principles. For a single-seat military aircraft, it is believed that these principles still apply, and that computer monitoring of system failures will further enhance their application. Three approaches to computer-augmented system monitoring are discussed.

Aerospace Medicine↗

Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave.

Edwards Lifesciences has recently introduced the FloTrac sensor and Vigileo monitor system for monitoring cardiac output continuously. It does not require thermodilution or dye dilution, but rather bases its calculations on arterial waveform characteristics in conjunction with patient demographic data. It is unique among arterial waveform cardiac output systems in that it does not require calibration with another method. Studies thus far indicate that it is robust and accurate over a wide range of cardiac output and clinical conditions. It will be valuable in the care of many patients, such as those with critical illness, cardiovascular dysfunction, trauma or undergoing major surgery.

Algorithms↗

A new miniaturized system for monitoring the epidural pressure in children and adults.

A new miniaturized epidural pressure transducing system for monitoring intracranial pressure (ICP) has been developed. The system is of the as yet smallest known dimensions. The transducer is implanted automatically coplanar to the dura via a burr hole of 4 mm diameter in the conscious patient without special surgical equipment. Application is possible in adults, children and infants. We have achieved a maximal resolution of 10(-3) mm of Hg. At a full scale range of 100 mm of Hg the zero-point drift is less than 1 mm of Hg/24 h.

Adult↗

Rapid and onsite BOD sensing system using luminous bacterial cells-immobilized chip.

A BOD monitoring system based on a bio-chip which immobilized luminous bacterium in micrometer-order holes were arrayed and fabricated by micro-machine techniques, was developed. The acrylic chip (3 cmx3 cm) comprises nine micro-holes (diameter: 700 microm or 1 mm, depth: 100 microm) arranged in a three by three array. Cells of the marine luminous bacterium, Photobacterium phosphoreum IFO 13896, which was grown at 15 degrees C for 15 h, were immobilized with 3% or 15% sodium alginate gel. BOD standard solutions or actual sample solution (approximately 10 microl) was fallen onto the cell-arrayed chip, and then the chip was incubated at 25 degrees C for 25 min. After incubation, bioluminescence from the each hole was gray-scaled and measured by a chemi-imager or newly developed onsite-type-monitoring system using a digital camera and a mobile-type personal computer. BOD values less than 16 ppm could detect by the chip, in particular, linear relationship at the concentrations between 0 and 16 ppm could be observed when luminous cells were immobilized with 3% sodium alginate gel. Steady bioluminescence was observed on the chip in the presence of BOD standard solution (GGA solution) which contained mineral elements. Furthermore, simultaneous detection of BOD values in various samples could be employed in the single chip. These results showed that the monitoring system with bio-chip could achieve high-through-put and onsite BOD detection. Our newly developed onsite-type BOD detection system which was used a digital camera and a (mobile) laptop computer was applied to measure and detect organic pollution due to biodegradable substances in wastewater treatment system. The same performance as the chemi-imager system was obtained for data of bioluminescence. The obtained BOD values showed a similar correlation with that of the conventional method for BOD determination (BOD5). These results suggested for successful achievement of high-though-put and onsite detection of BOD in practical.

Biosensing Techniques↗

[ComGIS-based regional landscape pattern monitoring information system].

Based on the requirement of scientifically managing landscape ecological data and dynamically monitoring regional landscape pattern, and with the Zhifanggou region in North Shaanxi Province as an example, this paper developed a regional landscape pattern monitoring information system (RLPMIS) by the combination of Delphi and MapX. The planning route and establishing method of the system were simply explained, and its basic structure and function were explicated. This system was mainly divided into four parts, i.e., data management module, query management module, landscape index analysis module, and landscape forecasting module. In this system, the graphics and the attributes of the landscape data were integrated entirely and managed effectively, and thus, the spatial information could be displayed, located and inquired in the RLPMIS. The landscape pattern could be comprehensively analyzed based on the various landscape indexes of landscape elements or whole landscape being calculated, and the landscape developing trend could be forecasted and simulated. At the same time, the statistical graph and table, which visually reflected the landscape pattern, developed and changed disciplinarian in different periods, could be dynamically generated.

Ecosystem↗

A computer-based, automated, telephonic system to monitor patient progress in the home setting.

In this report we describe an automated, telephonic system to monitor the progress of patients convalescing at home. The system includes a computerized central station that is capable of automated voice communication over the telephone, using voice reproduction, and touch-tone recognition. Peripheral hardware in multiple monitored homes need include only a touch-tone telephone, but may also be augmented by inexpensive, rudimentary diagnostic aids, such as a scale for body weight, a thermometer, or a blood pressure cuff and manometer. Current central hardware includes a NeXT computer, a fax modem, and a specialized telecommunications modem developed specifically for voice telecommunication using the NeXT. The central station acts like a robotic nurse in that it asks patients a series of questions and records the responses. The subjective questions to be asked are patient individualized and pre-selected by the physician from a question menu including items targeted specifically for the patient's disease or condition. In addition, clinical data such as body weight, blood pressure, and body temperature obtained from in-home diagnostic aids may be transmitted to the central station over the telephone using touch tones. The time-of-day and frequency of calling are pre-selectable, according to the patient's preference and clinical status. Data obtained by the central station can be easily accessed by the duty nurse via menu driven software. Reports depicting significant responses as a function of time are generated in graphical format to facilitate rapid identification of adverse trends. Hard copy reports can be dispersed directly by fax. Results from a pilot study show patients with cardiac disease readily use the system without difficulty or complaints. In one patient a five pound increase in body weight was detected, which prompted the patient's cardiologist to adjust his medication. In this way automated telephone follow-up can provide early detection of complications before they become severe, making the home environment safer and more secure for convalescence and contributing to reduced health-care costs.

Computer Systems↗

Functional mapping against Escherichia coli for the broad-spectrum antimicrobial peptide, thanatin, based on an in vivo monitoring assay system.

Previously, we established for the first time an in vivo monitoring assay system conjugated with random mutagenesis in order to study the structure-function relationship of the antimicrobial peptide, apidaecin [Taguchi et al. (1996) Appl. Environ. Microbiol. 62, 4652-4655]. In the present study, this methodology was used to carry out the functional mapping of a second target, thanatin, a 21-residue peptide that exhibits the broadest antimicrobial spectrum so far observed among insect defense peptides [Fehlbaum et al. (1996) Proc. Natl. Acad. Sci. USA 93, 1221-1225]. First, a synthetic gene encoding thanatin was expressed in a fused form with Streptomyces protease inhibitor protein, SSI, under the control of tac promoter in Escherichia coli JM109. Expression of the thanatin-fused protein was found to depend on the concentration of the transcriptional inducer, isopropyl-beta-D-thio-galactopyranoside (IPTG), and to parallel the degree of growth inhibition of the transformant cells. When a PCR random mutation was introduced into the structural gene for thanatin, diminished growth inhibition of the IPTG-induced transformed cells was mostly observed in variants as measured by colony size (plate assay) or optical density (liquid assay) in comparison with the wild-type peptide, possibly depending on the decreased antimicrobial activity of each variant. Next, wild-type thanatin and three variants screened by the in vivo assay, two singly mutated proteins (C11Y and M21R) and one doubly mutated protein (K17R/R20G), were stably overproduced with a fusion partner protein resulting in the efficient formation of inclusion bodies in E. coli BL21(DE3). The products were isolated in large amounts (yield 30%) from the fused protein by successive chemical and enzymatic digestions at the protein fusion linker site. Anti-E. coli JM109 activities, judged by minimum inhibitory concentration, of the purified peptides were in good agreement with those estimated semi-quantitatively by the in vivo assay. Based on the NMR solution structure and molecular dynamics, the structure-function relationship of thanatin is discussed by comparing the functional mapping data obtained here with the previous biochemical data. The functional mapping newly suggests the importance of a hydrogen bonding network formed within the C-terminal loop joining the beta-strands arranged antiparallel to one another that are supposed to be crutial for exhibiting anti-E. coli activity.

Amino Acid Sequence↗

Slimline vs. glass pH electrodes: what degree of accuracy should we expect?

BACKGROUND: Ambulatory pH monitoring is considered the gold standard for measuring oesophageal acid exposure, however, data comparing antimony and glass electrodes are limited. AIM: To compare the accuracy of the Slimline antimony pH monitoring system and a conventional glass electrode catheter pH monitoring system during ambulatory conditions. METHODS: Eighteen subjects (13 males, 23-45 years) underwent simultaneous pH monitoring using the Slimline antimony pH electrode and MIC M3 glass pH electrode pH monitoring systems for 12 h. Acid exposure was analysed and compared by manual extraction of the data onto an excel spreadsheet. RESULTS: There was no statistical difference in the median per cent time the pH was <4 recorded by the two systems (Slimline, 3%, Glass MIC M3, 2%, P = 0.77) and the correlation was excellent (r = 0.84). The difference in recorded reflux events was also not significantly different between the two systems, with the absolute difference being 23 events (s.d., 26). Point-by-point discrepancy was 28% (s.d., 18%), however, the agreement in terms of reflex events was excellent (Kappa value, 0.89, s.d., 0.09). CONCLUSION: Despite substantial point-by-point disagreement, the antimony Slimline pH catheter compares favourably to the Glass MIC M3 pH catheter in terms of measuring standard pH parameters.

Adult↗

Intraoperative monitoring of intracranial pressure in five dogs with space-occupying intracranial lesions.

Five dogs with space-occupying intracranial lesions underwent lateral craniectomy. Brain tissue pressures, reflective of intracranial pressure, were monitored during the surgical procedure, using a fiberoptic intracranial pressure monitoring system. The intracranial pressure monitoring cable was placed superficially in brain parenchyma on the side contralateral to the primary lesion. Recordings were made continually throughout the surgical procedure. Each dog was treated preoperatively with mannitol, which caused a decrease in intracranial pressure prior to craniectomy in only those dogs that initially had high intracranial pressure. Complications associated with use of the fiberoptic intracranial monitoring system were not evident. Although absolute values for pressure varied, pressure trends were helpful in determining effects of surgical manipulations on intracranial pressure in these dogs.

Animals↗

Invasive and non-invasive physiological monitoring of blunt trauma patients in the early period after emergency admission.

Pulmonary artery catheterization is usually not available to critically injured patients before admission to the intensive care unit, where action to correct values derived from such monitoring may be too late. Methods allowing hemodynamic monitoring during the early stages after trauma need to be explored. We used non-invasive monitoring systems (bioimpedance cardiac output monitoring, pulse oximetry and transcutaneous oximetry) to evaluate early temporal hemodynamic patterns after blunt trauma, and compared these to invasive PA monitoring. We included prospectively 134 patients monitored shortly after admission to the emergency department. The non-invasive impedance cardiac output estimations under extenuating emergency conditions approximated those of the thermodilution method: r = 0.83, r2 = 0.69, P<0.001; bias and precision were -0.02+/-0.78 l/min/m2. In the intensive care unit, these values improved further to: r = 0.91, r2 = 0.83, P<0.001; bias and precision = 0.36+/-0.59 l/min/m2. Monitoring revealed episodes of hypotension, low cardiac index, arterial hemoglobin desaturation, low transcutaneous oxygen and high transcutaneous carbon dioxide tensions, and low oxygen consumption during initial resuscitation. Low flow and poor tissue perfusion were more pronounced in non-survivors by both methods. Multicomponent non-invasive monitoring systems give continuous on-line, real-time displays of physiological data that allow early recognition of circulatory dysfunction. Such systems provide information similar to that provided by the invasive thermodilution method, and are easier and safer to use.

Adult↗

[Measurement and estimation system for monitoring physiologic parameters of man and biological feedback training].

A flexible instrumental programmed system realizing the biological feedback (BFB) method and permitting an easy tuning of the channels and parameters for treatment and reflection of physiological information is designed. A measurement and estimation real-time medical system for monitoring and BFB training is described, based on visual programming. An example of practical clinical application of the system to BFB training for the EEG rhythms is offered.

Alcoholism↗

Indirect measurement technique for a portable artificial heart drive system.

Monitoring of blood pressures is essential to the physiological control of the blood circulatory system when artificial hearts are used. Efforts to obtain long term, reliable direct measurements of blood pressures have not been successful because of blood clotting impairing the function of sensors, baseline drift, artifacts on measurements, and health hazard-related catheterization. This paper is concerned with an on-line estimation technique of blood pressures for a portable artificial heart drive system. The technique is based on measurements made for the drive system outside of the body and on mathematical models of the drive system components. The test of the on-line estimation technique with a mock circulatory loop showed successful correlations between the actual values and their optimal estimates. The developed approach offers the following advantages: elimination of blood clotting problems, accessibility to the pressure transducer for recalibration, and noninvasive location of the transducers.

Blood Pressure↗

Issues in selecting and using apnea documentation systems.

The primary purpose of apnea monitoring is to ensure adequate warning of certain life-threatening respiratory and cardiac events, often in infants monitored at home. However, parents often become frustrated by frequent alarms, and other may not use the monitor at all. Unfortunately, ECRI has received a number of incident reports in which infants have died while not connected to their monitors or where a failure to monitor was suspected. We believe that some of these deaths may have been prevented if monitoring had been used properly. The most important step that parents can take to achieve effective monitoring is to faithfully follow the directions of their doctor. In an effort to ensure parental compliance, documentation capability has been added to many of today's monitors. In addition, those involved in providing patient care, especially the prescribing physicians, durable medical equipment (DME) providers, report scorers, interpreting physicians, and other clinicians, should carefully review their monitoring programs and the available documentation monitoring systems to determine how they can best meet their patients' needs. Below, we discuss the factors to consider when contemplating documented apnea monitoring and when selecting a documented monitoring system. The documentation features discussed are those we considered to be distinguishing factors among the systems evaluated in this issue and affected how we rated and ranked these units.

Apnea↗

Comparative evaluation of Narcotrend, Bispectral Index, and classical electroencephalographic variables during induction, maintenance, and emergence of a propofol/remifentanil anesthesia.

UNLABELLED: In the present study, we sought to compare the abilities of Narcotrend (NT) with the Bispectral Index (BIS) electroencephalographic system to monitor depth of consciousness immediately before induction of anesthesia until extubation during a standardized anesthetic. We investigated 26 patients undergoing laminectomy. Investigated states of anesthesia were: awake, loss of response, loss of eyelash reflex, steady-state anesthesia, first reaction, and extubation during emergence. NT, BIS, spectral edge frequency, median frequency, relative power in delta, theta, alpha, beta, and hemodynamics were recorded simultaneously. The ability of all variables to distinguish between awake versus loss of response, awake versus loss of eyelash reflex, awake versus steady-state anesthesia, steady-state anesthesia versus first reaction and extubation were analyzed with the prediction probability. Effects of remifentanil during propofol infusion were investigated with Friedman's and post hoc with Wilcoxon's test. Only NT and BIS were able to distinguish all investigated states accurately with a prediction probability >0.95. After start of remifentanil infusion, only hemodynamics changed statistically significantly (P < 0.05). NT and BIS are more reliable indicators for the assessment of anesthetic states than classical electroencephalographic variables and hemodynamics, whereas the analgesic potency of depth of anesthesia could not be detected by NT and BIS. IMPLICATIONS: The modern electroencephalographic monitoring systems Narcotrend and Bispectral Index are more reliable indicators for the assessment of anesthetic states than classical electroencephalographic and hemodynamic variables to predict anesthetic conditions from before induction of anesthesia until extubation during a standardized anesthetic regime with propofol and remifentanil. The analgesic potency of depth of anesthesia could not be detected by Narcotrend and Bispectral Index.

Adult↗