Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “GLASSES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

An improved method for the quantification and recovery of rat uterine nuclear type II [3H]estradiol binding sites immobilized on a glass fiber matrix.

An improved assay for measuring ligand binding to extracted nuclear type II estrogen binding sites which involves preimmobilization on glass fiber filters is described. At least two classes of specific estrogen binding sites have been demonstrated in rat uterus as well as in a variety of other tissues and species and have been designated as type I and type II. Although the endogenous ligand to the type II binding site has recently been identified as methyl p-hydroxyphenyllactate (MeHPLA), tritiated estrogens are generally used for radiolabeling this site due to the susceptibility of MeHPLA to enzymatic hydrolysis in in vitro assays. After extracting the type II site from the nuclear matrix, ligand binding and protein stability appear to be significantly enhanced by first immobilizing the site on an artificial matrix, such as hydroxylapatite, before incubating with radiolabeled ligand. Immobilization of the extracted site on glass fiber filters results in higher specific binding and lower nonspecific binding when compared to hydroxylapatite and a number of other immobilization matrices. The glass fiber ligand exchange procedure for measuring type II binding can also be performed on smaller samples and requires less time than other methods. Type II sites are significantly stabilized when immobilized on glass and exhibit sigmoidal binding curves when incubated with increasing concentrations of [3H]estradiol and [3H]estrone and display inhibition data characteristic of that observed using more traditional assays.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Fibrin configuration on glass led to decrease of neutrophil adherence in systemic lupus erythematosus.

Using a previously developed in vitro assay of glass adherence of neutrophils following blood clotting, we compared the results of new patients with systemic lupus erythematosus (SLE), juvenile rheumatoid arthritis (JRA) and those of normal controls. In acute phase of the disease, all 33 patients (100%) of SLE, 2 of 35 patients (5.7%) with JRA had a significantly low neutrophil adherence to glass surface (less than 25% of the normal values). During 2 years follow-up in 18 patients with SLE from the onset of the disease, we consistently observed the low cell adherence during the relapses of the disease in all the patients. When remains of glass surfaces were examined under scanning electron microscope (SEM), we found a notable morphologic difference of fibrin configuration between the specimens of active SLE and normal controls. We conclude that the varied results of neutrophil adherence on glass may reflect the forming of different fibrin configuration induced by the in vitro contact system of coagulation. The findings may explain the increased thrombotic complications reported in patients with active SLE.

Adolescent↗

Release of 6-keto-prostaglandin F1 alpha and thromboxane B2 from mouse peritoneal macrophages during their adhesion and spreading on a glass surface.

The release of 6-keto-prostaglandin F1 alpha (6KF1 alpha) and of thromboxane B2 (TXB2) from cells were investigated using mouse peritoneal exudate cells (PECs) and non-cultured peritoneal macrophages. They were prepared by adhesion to glass dishes and incubated for 1 hr at 37 degrees C in 5% CO2 in air. Both the percentage of spreading macrophages and the release of 6KF1 alpha and TXB2 increased in proportion to the incubation time. 6KF1 alpha and TXB2 were released from the macrophages, not from the non-coated glass dishes, the spreading of macrophages was hardly detected and lower amounts of 6KF1 alpha and TXB2 were released from these cells compared with cells incubated in non-treated glass dishes. These findings suggest that adhesion with the correlated spreading of macrophages on glass dishes serve as a considerable physical factor for the release of 6KF1 alpha and TXB2.

6-Ketoprostaglandin F1 alpha↗

Effects of etching and rinsing times and salivary contamination on etched glass-ionomer cement bonded to resin composites.

This study investigated the effect of salivary contamination on glass-ionomer/resin-composite bond strength after establishment of an appropriate etching and rinsing time for the glass-ionomer cement. Three hundred and thirty samples of glass-ionomer cement (Ketac-Fil) were injected into cavities prepared in acrylic molds. Groups containing 15 samples each were etched for 0, 15, 30, or 60 sec, after which Scotchbond and either Silux or P-30 were applied and polymerized. The samples were stored under water for 24 hr at 37 degrees C and were then tested in shear. A 30-second etching time was found to be optimal when Silux and P-30 were considered together. In a similar manner, a 20-second optimal rinsing time was determined. Samples of glass-ionomer cement were then contaminated with saliva, dried, and bonded to composite resins and tested in shear as before. Significantly lower bond strengths resulted than with the uncontaminated controls. Efforts to clean contaminated samples by rinsing or re-etching failed to increase the bond strength obtained with the contaminated samples.

Acid Etching, Dental↗

Creep behavior of glass-ionomer restorative materials.

The creep of microspecimens of five glass-ionomer filling materials and one glass-ionomer-cermet cement was studied by means of a torsional creep apparatus. The glass-ionomer specimens were aged one week and conditioned in 37 degrees C water. Shear stress of 2.47 x 10(-4) N.m was maintained for three h, and recovery was followed for 50 h. Creep curves were obtained at 21, 37, and 50 degrees C. The effect of temperature increase was studied. All the glass ionomers exhibited linear visco-elastic behavior at low deformations. Their shear moduli and resistance to creep were similar to those of some composites measured by the same method. The increase of temperature influenced the creep behavior and moduli of the materials (i.e., increased creep and residual strains and decreased shear modulus). Although the applied torque was very small, there was permanent deformation, the result of viscous flow in all experiments which was more pronounced at 50 degrees C.

Cermet Cements↗

Optimization of glass-ceramic crystallization based on DTA exotherm analysis.

OBJECTIVES: Crystallization of glass-ceramics is traditionally achieved through a two-stage heat treatment consisting of an isothermal nucleation stage followed by an isothermal growth stage. A method for determining a more efficient heat treatment schedule for a glass-ceramic material using a thermal analysis technique is proposed. The goal of an optimized heat treatment schedule is the production of a glass-ceramic with a desired microstructure (number of crystals per volume) in the shortest amount of time. METHODS: The proposed method involves differential thermal analysis (DTA) to measure glass crystallization exotherm characteristics which are correlated with the population density of growing crystals, and therefore, to the effectiveness of any prior heat treatment. Traditional thermal processing parameters were investigated and optimized. A method for generating a more efficient heat treatment schedule composed of a series of increasing heating rates was also demonstrated. RESULTS: The thermal analysis method measured a significant effect upon the number density of crystals generated as a function of several experimental variables. Micrographs from samples crystallized with a more time-efficient heat treatment schedule were shown to have equivalent crystal number densities compared to those crystallized with a more time consuming, traditional schedule. SIGNIFICANCE: This work demonstrated that a rapid thermal analysis method was capable of measuring the relative effectiveness of heat treatment schedules to generate crystalline populations. A novel heat treatment schedule was developed based on progressive adjustment of processing heating rates to generate the maximum crystal population in the shortest amount of time.

Ceramics↗

Transverse strength and fatigue of denture acrylic-glass fiber composite.

OBJECTIVES: The aims of this experiment were: 1) to test the effect of a high concentration of continuous glass fibers on the transverse strength of test specimens made of heat-cured acrylic resin; and 2) to determine the fatigue weakening of both unreinforced and continuous glass fiber-reinforced specimens of heat-cured acrylic resin shaped into upper complete dentures. METHODS: A three-point loading test was used to determine the transverse strength of test specimens (n = 30 per group). The fatigue test was the constant deflection test (n = 10 per group). RESULTS: The results revealed that, compared to unreinforced specimens, continuous glass fibers at a concentration of 58 wt% enhanced the transverse strength of the test specimens up to 146% (p < 0.001) and increased the fatigue resistance (p < 0.001) during 5 x 10(5) loading cycles. SIGNIFICANCE: This study suggests that by incorporating glass fibers into PMMA denture bases, the strength of the denture can be increased.

Composite Resins↗

Resin-modified glass ionomers for luting posterior ceramic restorations.

OBJECTIVES: Until recently, esthetic inlay restorations in posterior teeth have been limited to cavities surrounded by enamel. Dentin adhesive systems in combination with luting composites and light-cured resin-modified glass ionomer cements offer a possibility for bonding ceramic inlays to cavities when the cervical margin is in dentin. This study was designed to compare in vitro marginal integrity of ceramic inlays bonded to dentin to restorations placed in cavities with margins located entirely in the enamel. METHODS: In the present in vitro study, the sealing abilities of a dentin bonding agent/luting composite combination (Syntac/Dual Cement, Vivadent) and resin-modified glass ionomers (Photac Fil, Photac Bond, ESPE; Dyract, De Trey Dentsply; Fuji II LC, GC Dental Industrial Corp.; and Vitremer, 3M Dental Products) used as luting agents in cavities extending beyond the cemento-enamel junction, were compared to the sealing abilities of a conventional luting composite (Vita Cerec Duo Cement, Vita) in cavities within sound enamel. SEM analysis and dye penetration were performed to evaluate marginal integrity at the cervical cavity margins. RESULTS: The dentin bonding agent/luting composite combination (Syntac/Dual Cement) rendered a marginal seal within the dentin similar to the quality obtained with the conventional luting procedures within sound enamel. When three out of the five resin-modified glass ionomers were used as luting agents (Dyract, Fuji II LC and Vitremer), the results were comparable to those reported for the dentin bonding agents and the conventional method. SIGNIFICANCE: Light-cured resin-modified glass ionomer cements may be considered as an alternative to dentin bonding agents when the cavity margins of ceramic inlay restorations are within the dentin. However, further studies, e.g., wear resistance, must be performed.

Bicuspid↗

Phosphate glass cement bone graft.

The objective of this study was to prepare cement-forming substances from phosphate glasses for use as a bone graft. The glass-forming system of CaO-SrO-Na2O-P2O5 was explored and ten phosphate glasses were prepared of varying compositions. Cements were made by reducing the glass to powders and reacting them with a water solution of calcium hydroxide or phosphoric acid. The cements were evaluated by X-ray diffraction, electron microscopy, density and porosity measurements, pH change during reaction and solubility in water. Because of the water solubilities of these cement materials, they may be useful as bone grafts containing drugs such as antibiotics which would be slowly released as the graft material degrades.

Biocompatible Materials↗

Short-term behaviour of two similar active glasses used as granules in the repair of bone defects.

The bioactivity of two similar vitreous materials used in the form of granules of 'critical' size was investigated in bone defects in jaws of two sheep. The granules consisted of Hench's Bioglass and another glass with the same chemical composition made in Italy. Two months after implantation, the sheep were killed and elemental analyses carried out on sections of the embedded jaws. The microanalyses for both the glasses showed a diffusion from the granules towards the surrounding tissue of silicon and sodium, and an inverse diffusion (from the surrounding tissue towards the granules) of calcium and phosphorus. The degradation for the Italian glass was slower than for the Bioglass. No significant osteoinduction was seen after that time at the interface of the glass granules or in the bone pocket.

Animals↗

Analysis of the in vivo reactions of a bioactive glass in soft and hard tissue.

A bioactive glass, S53P4, was implanted as granules subcutaneously in muscles and connective tissue of rabbits, as well as in the mandibular bone of a sheep. After the implantation period of 2-3 months, cross-sections were prepared and studied by scanning electron microscopy and energy dispersive X-ray analysis. The glass reacted essentially in the same way in all types of tissue. The granules consisted of an unreacted core and a reacted layer with a silica-rich and calcium phosphate-rich zone. Large hydroxyapatite crystals were occasionally found on top of the calcium phosphate surface of the granules implanted in soft tissue. On the basis of elemental analysis of the reaction layers it was found that the release of calcium from inside the glass is sufficient to account for the formation of the calcium phosphate surface layer, whereas the release of phosphate from the glass is not sufficient.

Animals↗

19F NMR spectroscopy of glass ceramics containing fluorapatites.

Glass ceramics which contain apatite crystals are used as implant materials in medicine. Because most of these glass ceramics are comprised of fluoride-containing glass compositions, the apatites should be fluoride-containing apatites. The fluorine content of these apatites is important for medical applications. The purpose of the current study was to determine the possibilities of measuring the fluorine content of these apatites. High resolution solid state 19F Magic Angle Spinning (MAS) Nuclear Magnetic Resonance (NMR) spectra of apatite-containing glass ceramics have been obtained. Using the correlation between the isotropic 19F chemical shift and the fluorine content, it was possible to determine the fluorine content of the apatites.

Apatites↗

Albumin adhesion on some biological and non-biological glasses and connection with their Z-potentials.

Evaluating the properties of absorption of albumin on the surface of biomaterials is an important matter in developing information in the field of biomaterials, since it is the most abundant protein present in the human body and it is an any case the first protein that rapidly flows in quantity in a damaged area of a tissue. This study has taken into consideration three different biological glasses and the results were compared with those coming from three different biologically inert glasses. The values obtained were also compared with those coming from the measurements of the Z-potential of the same glasses to verify if a correlation between albumin absorption and Z-potential of the glasses exists. Both types of measurements were carried out at two different pH values: 4.5 and 7.4. These values were selected since the first may be indicative of an acid environment to simulate that of macrophagic action (other than of inflammatory states) and the second simulates the normal condition of a tissue like healthy bone.

Absorption↗

In vitro investigation of fluoride ion release from four resin-modified glass polyalkenoate cements.

Conventional glass ionomer cements are known to release fluoride ions to the surroundings. Recently, resin-modified glass ionomer cements have been produced. These have differing chemical formulations and this may affect their ability to release fluoride ions. The study evaluates both the fluoride release and compressive strength of one conventional and four resin-modified glass ionomer cements with respect to time. The results showed that the formulation of the resin-modified materials influenced the fluoride release. One resin-modified glass ionomer (PhotacFil) released more fluoride than all other materials, while Vitremer, Fuji II LC and Chemfil Superior release similar amounts. Variglass had a very much smaller elution of fluoride ions. This suggests that there is considerable variation in fluoride release between materials of similar generic origin. The compressive strength of these materials was not affected with time.

Biocompatible Materials↗

Method for enhancing the fluoride release of a glass-ionomer cement.

The cariostatic action of the glass-ionomer cement has been attributed to its sustained release of fluoride. The fluoride in the set cement originates from the glass particles which are eroded, in part, during the setting reaction. In this study a water-activated glass-ionomer was mixed with sodium fluoride (NaF) solutions of different concentrations (0%, 2% and 4%). The different cements were used to prepare discs which were stored individually in demineralized water at 37 degrees C, the fluoride concentration of the storage solutions were measured, at intervals, until the specimens were 80 days old. The effect of the different mixing solutions on the working and setting times and compressive strength were also determined. It was found that the cement mixed with the 4% solution of NaF released significantly more fluoride than the water mixed control. The fluoride solution mixed materials had longer setting times than the control, but there was no significant difference in the compressive strengths. All the materials became progressively stronger on storage. Mixing the cement with a 4% solution of NaF increased the initial fluoride release of the glass-ionomer without seriously affecting other physical properties.

Delayed-Action Preparations↗

A versatile technique for patterning biomolecules onto glass coverslips.

A fast, inexpensive, and versatile technique for patterning the surface of glass coverslips with molecules of biological interest is described. The technique combines photolithographic, silane-coupling, and protein adsorption procedures to pattern coverslips with amines, alkanes, and proteins with micrometer spatial resolution. The attachment of amines and alkanes was verified using contact angle and X-ray photoelectron spectroscopic (XPS) measurements. XPS results showed that amines and alkanes were attached in 1-4 nm thickness covering approximately 20% and 45%, respectively, of the surface. Patterns of amines were visualized using fluorescent staining, and patterns of proteins were detected immunochemically. Patterned coverslips were used to investigate adhesion and neurite outgrowth of mouse neuroblastoma (N1E-115) cells. Cells were examined on the following patterns: alkane-glass, protein-glass, amine-alkane, and amine-protein. Cell attachment and neurite outgrowth on patterned coverslips displayed the following preferences: laminin, fibronectin, or collagen IV > amine or glass > alkane or bovine serum albumin. This patterning method should be useful for studies of cell-surface interactions, cell migration, nerve regeneration, and the formation of neural networks in vitro.

Alkanes↗

A simplified method for manufacturing glass-insulated metal microelectrodes.

A simplified method to manufacture durable, glass-insulated, tungsten microelectrodes with sufficient control of the final electrode impedance is described. This method requires only two instruments, an electrolytic etcher for wires and pipette puller, for manufacturing these electrodes. The manufacture of these electrodes involves 3 steps: (1) etching tungsten wire to sharpen the tip, (2) insulating the electrode by pulling a glass pipette over the sharpened tungsten wire and (3) assessing and adjusting the tip exposure and impedance of the electrode to meet recording requirements. Control over the electrode impedance is easily accomplished by varying the distance between the uppermost portion of the heating coil and the sharpened wire tip before a glass pipette is pulled over the wire tip. This distance determines the area of tip exposure and also the location where the glass insulation ends and the exposed electrode tip begins. A performance test of these electrodes in a chronically prepared monkey showed that they were strong enough to repeatedly penetrate thickened dura mater without significant changes in impedance and to isolate cortical neuronal activity after these multiple penetrations. Furthermore, the strength of these microelectrodes eliminated the need to remove reactive granular tissue from the dura overlying the recording site.

Animals↗

Adsorption-elution with negatively and positively-charged glass powder for the concentration of hepatitis A virus from water.

Two methods based on virus adsorption and elution from glass powder were developed for the concentration of hepatitis A virus (HAV) from large volumes of water. The cytopathogenic pHM-175 strain of HAV was used to test these procedures in tap water, fresh water, sea water and raw sewage. HAV was quantitated by a plaque assay in the FRhK-4 cell line. HAV was concentrated by glass powder adsorption-elution from 20-liter samples with satisfactory efficiencies in all types of water: 100% for tap water, 80% for freshwater, 75% for sea water and 61% for sewage. The charge of glass powder was modified by polyethylenimine treatment to avoid the need to pretreat the sample. Concentration efficiencies of HAV in 20-1 samples through adsorption to and elution from positively-charged glass powder were 100% for tap water, 94% for sea water, and 61% for fresh water and sewage. Both methods were used for the detection of wild-type HAV in raw sewage. Wild-type HAV in concentrated sewage samples was detected by molecular hybridization with a digoxigenin-labelled cDNA probe.

Adsorption↗