[Scaphoid percutaneous osteosynthesis by screw using computer assisted surgery: an experimental study].

Scaphoid fractures are sometimes difficult to diagnose and even more difficult to fix. Recent progress such as miniaturization of osteosynthesis material, adoption of the percutaneous route, and widening of the indications to include undisplaced fractures has still not abolished complications. In this context, computer assisted surgery (CAS) may be useful and deserves further study. To apply it to the scaphoid, it is initially necessary to immobilize the "wrist hand fingers" unit in a device adapted to make it a rigid unit. It is then necessary to choose the correct configuration of CAS system. The pedicular fluoroscopic navigation system, which is apparently similar to scaphoid screw insertion, was chosen for this study. The goal of this study is to define the osteosynthesis bases of the scaphoid with CAS. A fresh anatomical subject divided at the elbow joint was prepared at the DETERCA laboratory of the university Bordeaux 2. The solid "wrist hand fingers" unit was immobilized in extension and ulnar deviation of the wrist by a malleable, stable and radio transparent device. The first stage consisted of a calibration of the surgical instruments and the "wrist hand fingers" unit, with a three-dimensional optical localization system. The guide wire was simulated by a gauged stylet. When the axis and the length of the screw had been determined virtually, insertion of the guide wire was carried out under guidance of the virtual images of the computer's screen, without the assistance of the fluoroscopy. Finally the canulated screw was inserted over the guide wire. Insertion was stopped when the screw reached the intra osseous virtually predetermined length. A check using conventional fluoroscopy made it possible to ensure the correct positioning of the screw. Our results show that it is possible to insert a screw into a scaphoid without conventional fluoroscopy, by using the fluoroscopic navigation system. The procedure was performed without difficulty, apart from the need for calibration of the navigation tools one by one. The solid immobilization device, although having the potential for micromovement, did not lead to any misdirection of the guide wire or screw. Our technique cannot be employed at the moment in live human surgery. Its limits are of a geometrical nature "two images available in two planes", data processing "non-specific software dedicated", instrumental "instrument calibration, micromobility of the immobilisation device" and live surgery "no current validation on a fractured scaphoid". Meantime, the development of a percutaneous scaphoid osteosynthesis procedure by CAS can only bring advantages: reduction in the learning curve, widening of the indications, comfort in the technique, reduction in the errors of ostesynthesis and, reduction in the exposure to x-rays. In the current state of knowledge, the method would only be applicable to undisplaced fractures.

Bone Screws↗

Influence of needle position on lumbar segmental nerve root block selectivity.

BACKGROUND AND OBJECTIVES: In patients with chronic low back pain radiating to the leg, segmental nerve root blocks (SNRBs) are performed to predict surgical outcome and identify the putative symptomatic spinal nerve. Epidural spread may lead to false interpretation, affecting clinical decision making. Systematic fluoroscopic analysis of epidural local anesthetic spread and its relationship to needle tip location has not been published to date. Study aims include assessment of epidural local anesthetic spread and its relationship to needle position during fluoroscopy-assisted blocks. METHODS: Patients scheduled for L4, L5, and S1 blocks were included in this prospective observational study. Under fluoroscopy and electrostimulation, they received 0.5 mL of a mixture containing lidocaine 5 mg and iohexol 75 mg. X-rays with needle tip and contrast were scored for no epidural spread (grade 0), local spread epidurally (grade 1), or to adjacent nerve roots (grade 2). RESULTS: Sixty-five patients were analyzed for epidural spread, 62 for needle position. Grade 1 epidural spread occurred in 47% of L4 and 28% of L5 blocks and grade 2 spread in 3 blocks (5%; L5 n = 1, S1 n = 2). For lumbar blocks, the needle was most frequently found in the lateral upper half of the intervertebral foramen. Epidural spread occurred more frequently with medial needle positions (P = .06). CONCLUSION: The findings suggest (P = .06) that the risk of grade 1 and 2 lumbar epidural spread, which results in decreased SNRB selectivity, is greater with medial needle positions in the intervertebral foramen. The variability in anatomic position of the dorsal root ganglion necessitates electrostimulation to guide SNRB in addition to fluoroscopy.

Adult↗

Comparison of the Sideris and Amplatzer septal occlusion devices.

The results of transcatheter atrial septal defect (ASD) occlusion with 2 different devices (Sideris adjustable buttoned device vs Amplatzer Septal Occluder) were compared in 2 consecutive series of patients. Comparative outcomes were assessed by whether a device was implanted or not, by complications and fluoroscopy time of implantation, and by the incidence of residual shunting on transthoracic echocardiography at follow-up. The patient and defect characteristics were similar in both groups. Twenty-eight of 33 Sideris devices and 37 of 39 Amplatzer devices were implanted. The fluoroscopy time for the Amplatzer implants was 13.4 minutes (range 8 to 41) compared with 23.7 minutes (range 11 to 60.6) for the Sideris implants (p <0.001). The complete occlusion rate for the Amplatzer device was 93% compared with 44% for the Sideris device at 1 year (p <0.001). In conclusion, the Amplatzer device produces higher occlusion rates of ASDs with shorter fluoroscopy times.

Adolescent↗

Cardioscopic guidance of linear lesion creation for radiofrequency ablation.

BACKGROUND: The broad use of catheter ablation of atrial fibrillation is limited by the difficulty inherent in creating transmural linear lesions under fluoroscopy. Therefore, we evaluated cardioscopy as a more accurate method of guiding the catheter for the placement of linear lesions. METHODS: Nineteen swine underwent endocardial ablation to create linear conduction block lesions in the right atrium under cardioscopy (group I, n = 13) or fluoroscopy (group II, n = 6). In both groups, the linear lesion was created between the superior and inferior vena cava, perpendicular to hexapolar electrodes placed on the epicardial surface. Each swine received two pairs of epicardial hexapolar electrodes: one pair to measure the conduction delay time across the ablated line and another pair for pacing. The time spent to complete the ablation, number of trials and effective ablations, ratio of effective ablations to trials, length of the lesion, conduction delay under pacing, and postmortem pathology were compared between the two groups. RESULTS: Statistically significant differences were found for the time required for ablation, ratio of effective ablation to total number of trials, and conduction delay. Histologic analysis revealed more homogenous, continuous lesions in group I. CONCLUSIONS: Cardioscopy facilitated the placement of a conduction block line more efficiently than ablation performed under fluoroscopy. Landmarks of tissue relevant to ablation are readily visualized by cardioscopy. Moreover, cardioscopy can be useful for the development of a guiding catheter for the ablation of atrial fibrillation.

Animals↗

Value of saphenous vein graft markers during subsequent diagnostic cardiac catheterization.

BACKGROUND: Although saphenous vein graft (SVG) markers have been available for many years, they have not been widely used in coronary artery bypass graft (CABG) surgery. This is likely due to the paucity of data regarding the utility of these markers in postsurgery cardiac catheterization. METHODS: We performed a prospective study of all post-CABG patients undergoing cardiac catheterization at Barnes-Jewish Hospital over a 6-month period to test our hypothesis that SVG markers would have a beneficial effect on these procedures. Differences in total procedure (arterial) time, time to image only the SVGs, fluoroscopy time, amount of contrast used, number of aortotomies, and number of views required were compared in patients with and without markers. RESULTS: Post-CABG patients undergoing catheterization who had markers (n = 76) required significantly less total procedure time (p = 0.007), fluoroscopy time (p = 0.02), and contrast use (p = 0.008). Even after adjusting for the numbers of SVG ostia and numbers of cine views, patients with markers still required less catheterization and fluoroscopy time (p < 0.01, p < 0.02) and time to image only the SVGs (p < 0.05) than those without markers (n = 106). CONCLUSIONS: SVG markers improve the efficiency of post-CABG catheterizations; they decrease the exposure of patients and cardiologists to ionizing radiation, and they decrease the exposure of patients to potentially toxic contrast agents. SVG markers are beneficial to the vast majority of post-CABG patients.

Cardiac Catheterization↗

Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study.

A prospective controlled clinical study was performed to compare fluoroscopic guidance with fluoroscopy-based surgical navigation for distal locking of intramedullary implants. Forty-two patients with fractures of the lower extremity treated by intramedullary nailing were divided in two groups: distal locking either with fluoroscopic guidance (group I) or with surgical navigation (group II). The average fluoroscopic time to insert one interlocking screw with fluoroscopic guidance was 108 s compared with 7.3s in the navigation group. The average procedure time to insert one interlocking screw in group I was 13.7 min compared with 17.9 min in group II. The drill bit failed to pass through the interlocking hole in one patient from group II. There was no significant difference in the technical reliability between both groups. Fluoroscopic times to achieve equivalent precision are reduced with fluoroscopy-based surgical navigation compared with fluoroscopic guidance. Fluoroscopy-based surgical navigation is recommended for intraoperative guidance in situations where reduction of exposure to radiation is considered advantageous over the increase of procedure time.

Female↗

Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing.

During 41 procedures of intramedullary nailing of femoral and tibial fractures, the primary surgeon and the first assistant wore ring dosimeters on their dominant index fingers. While the average fluoroscopy time per procedure was 4.6 min, the average dose of radiation to the dominant hand of the primary surgeon was 1.27 mSv and 1.19 mSv to the first assistant. The dose limit for the extremities is 500 mSv per year, as recommended by the International Commission on Radiological Protection. Extrapolation of the mean dose of the primary surgeon and first assistant per procedure of 1.23 mSv leads to the result that the recommended dose limit of 500 mSv would only be exceeded if more than 407 intramedullary nailing procedures are carried out per year. The duration of fluoroscopy time correlated with the radiation dose to the hands of the surgeons, though it was determined by phantom measurements that the majority of radiation exposure occurred during brief exposures of the hands in the direct X-ray beam on the X-ray tube near side of the patient. In order to assess the surface doses of the thyroid gland to the primary surgeon with and without a lead shield, we performed in vitro measurements during operative procedures of the lower leg simulating different intraoperative situations under fluoroscopic control. The average registered ionizing dosage without a thyroid shield was approximately 70 times higher than with thyroid lead protection. In a previous study we found average fluoroscopy times during intramedullary nailing of the tibia and femur of 4.6 min per procedure. Extrapolation of this value leads to the result, that even when 1000 intramedullary nailings were carried out without wearing lead protection, only 13 per cent of the dose limit recommended by the International Commission on Radiological Protection for the thyroid of 300 mSv per year would be reached; by wearing the lead protection only 0.2 per cent of the recommended dose would be reached.

Femoral Fractures↗

Radiation exposure during ureteroscopy.

Use of fluoroscopy during ureteroscopy increases the risk of radiation exposure to the urologist and patient. Radiation entrance dosages were measured at skin level in 37 patients, and at the neck, trunk and finger of the urologist, and neck and trunk of the circulating nurse. Radiation exposure time was measured in 79 patients, and was related to the purpose of the procedure and the type of ureteroscope used, whether rigid or flexible. Exposure could be minimized by decreasing the fluoroscopy time. A portable C-arm fluoroscopy unit with electronic imaging and last image hold mode should be used to minimize exposure time. Lead aprons and thyroid shields should be used by the urologist and other personnel in the endoscopy room.

Endoscopy↗

Unrecognized chondral penetration by a Herbert screw in the scaphoid.

The Herbert bone screw as developed by T. Herbert in the early 1980s has been used in the treatment of scaphoid fractures and nonunions. Reports on clinical efficacy have been accompanied by discussions of technical difficulties. This study determines if the curvilinear surface of the proximal pole of the scaphoid leads to errors in screw length and penetration into the joint. The screw was inserted in cadaveric wrists using the technique described by Herbert. Plain x-ray films were taken in the anteroposterior and lateral planes and fluoroscopy was used through 360 degrees. From the imaging studies, we decided whether subchondral penetration of the screw had occurred. The scaphoids were then dissected and the dorsal poles inspected. In our six specimens, two screws were found to be penetrating subchondral bone. The plain x-ray films were accurate in five of six specimens. Fluoroscopy was accurate in all six. Fluoroscopy during placement of the Herbert screw may decrease the rate of subchondral penetration.

Bone Screws↗

Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures.

OBJECTIVES: The aim of this study was to accurately assess the radiation exposure received by patients during cardiac catheterization in a large sample representative of the current state of practice in cardiac angiography. BACKGROUND: Radiation exposure to patients and laboratory staff has been recognized as a necessary hazard in coronary angiography. The effects on x-ray exposure of the increased complexity of coronary angiographic procedures and, in particular, the increasing use of coronary artery stenting, have not been adequately addressed in previous studies. METHODS: X-ray exposure measurements were performed on a consecutive series of 972 patients undergoing 992 diagnostic and interventional studies in the Mayo Clinic catheterization laboratory within an eight week period in late 1997. Data were acquired from 706 diagnostic procedures and 286 interventional procedures using a real-time exposure measurement system to continuously calculate and record the exposure rate and total exposure, reflecting all parameters relevant to the specific patient and procedure situation. RESULTS: The median exposure for all 992 procedures was 41.8 mC/kg (162.1 R); the corresponding values for diagnostic and interventional procedures were 34.9 and 95.6 mC/kg, respectively (135.3 vs. 370.5 R). There were significant differences in the fluoroscopy exposure time between diagnostic and interventional procedures: 4.7 min vs. 21.0 min. Heavier patients (>83 kg) received x-ray exposures at a significantly higher rate than did lighter patients (<83 kg) during both fluoroscopy and cine; 44.9 mC/kg/min (173.9 R/min) vs. 27.9 mC/kg/min (108.3 R/min) for cine exposure rate and 2.3 mC/kg/min (8.8 R/min) vs. 1.5 mC/kg/min (5.8 R/min) for fluoroscopy exposure rate. CONCLUSIONS: Changes in practice have led to higher values for patient x-ray radiation exposures during cardiac catheterization procedures. The real-time display and recording of x-ray exposure facilitates the reduction of exposure in the catheterization laboratory.

Aged↗

Aortoscopy: a guidance system for endoluminal aortic surgery.

PURPOSE: The aim of this project was to evaluate the feasibility of aortoscopy for guidance of endoluminal aortic procedures and to determine whether aortoscopy has advantages over fluoroscopy in a pig model. METHODS: To establish feasibility aortoscopic guidance was used for making endoluminal aortic measurements, cannulating small arteries for arteriograpy, and placing intraaortic stents and grafts in 11 pigs. To compare aortoscopy and fluoroscopy measurements were made and stents were placed by a surgeon using only aortoscopic guidance in 10 pigs and by an interventional radiologist using only fluoroscopic guidance in 10 pigs. Postmortem dissections were performed to determine measurement and device placement accuracy. RESULTS: In the feasibility study aortoscopic measurements differed from postmortem measurements by a mean distance (+/- SD) of 1.2 +/- 0.2 mm. Stents and grafts were placed a mean of 2.3 +/- 1.9 mm distal to the most inferior renal artery with no stent covering an orifice. All attempts at cannulating spinal arteries greater than 2 mm in diameter were successful. In the comparison of aortoscopic and fluoroscopic guidance, fluoroscopic measurements differed from postmortem measurements by 2.6 +/- 2.4 mm (p = 0.223). Stents placed with aortoscopic guidance were 1.1 +/- 1.3 mm distal to the most inferior renal artery, whereas stents placed with fluoroscopic guidance were 3.4 +/- 2.5 mm distal to the most inferior renal artery (p = 0.019). CONCLUSIONS: These results demonstrate that aortoscopy is a useful guidance system for endoluminal aortic procedures and may have advantages over fluoroscopy alone.

Angioscopes↗

Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures.

PURPOSE: Four techniques used to estimate radiation risk were compared to determine whether commonly used dosimetry measurements permit reliable estimates of skin dose. Peak skin dose (PSD) is known to be the most reliable estimate of risk to skin. The purpose of this study is to determine peak skin dose with use of real-time software measurements and to correlate other measures of dose with PSD. MATERIALS AND METHODS: Two hundred twelve patients undergoing arch aortography and bilateral carotid arteriography (referred to as "carotid"), abdominal aortography and bilateral lower extremity runoff ("runoff"), or tunneled chest wall port placement ("port") were studied. Fluoroscopy time, dose-area product (DAP), and cumulative dose at the interventional reference point were recorded for all procedures; PSD was recorded for a subset of 105 procedures. The dose index, defined as the ratio between PSD and cumulative dose, was also determined. RESULTS: In general, correlation values for comparisons between fluoroscopy time and the other measures of dose (r =.29 to.78) were lower than values for comparisons among DAP, cumulative dose, and PSD (r =.52 to.94). For all procedures, pair-wise correlations between DAP, cumulative skin dose, and PSD were statistically significant (P <.01) The ratio between PSD and cumulative skin dose (dose index) was significantly different for ports versus other procedures (carotid, Z = 4.62, P <.001; runoff, Z = 4.52, P <.001), but carotid and runoff procedures did not differ significantly in this regard (Z = 0.746, P =.22). Within each individual procedure type, the range of values for the dose index varied 156.7-fold for carotid arteriography, 3.2-fold for chest ports, and 175-fold for aortography and runoff. CONCLUSION: Fluoroscopy time is a poor predictor of risk because it does not correlate well with PSD. Cumulative dose and DAP are not good analogues of PSD because of weak correlations for some procedures and because of wide variations in the dose index for all procedures.

Computer Systems↗

Biopsy of lung nodules with use of I-I device under intermittent CT fluoroscopic guidance: preliminary clinical study.

PURPOSE: To investigate the efficacy of computed tomography (CT) fluoroscopy and a new needle holder (the I-I device) in lung nodule biopsy. MATERIALS AND METHODS: The I-I device is made of acrylate resin and was used to keep the entire needle in the tomographic plane. This study consisted of biopsies of 79 lung nodules in 77 patients. The final diagnoses were malignant in 54 patients, benign in 23, and unconfirmed in two. The biopsy procedure time from the beginning of the CT fluoroscopy procedure to the removal of the needle was measured for 24 needle passes. The radiation dose on the physician's hand was measured in five cases with use of a thermoluminescence ring. RESULTS: Fifty-one malignant and 20 benign lesions were correctly diagnosed with histologic specimens (90%). In 58 of 77 patients (75%), the biopsy procedures were completed within a single breath-hold. Pneumothorax occurred in 20 of 77 patients (26%) and chest tube insertion was required in five. The incidence of pneumothorax was significantly lower in patients who held their breath during biopsy procedures compared with those who did not (P < .0001; chi2 test). The biopsy procedure time ranged from 15 to 39 seconds (mean: 28.2 sec). The mean radiation dose on the physician's hand was 2 mSv/case. CONCLUSION: The diagnostic accuracy of biopsy with use of the I-I device under CT fluoroscopic guidance is comparable with that of the conventional method; however, a combination of CT fluoroscopy and the I-I device enables rapid biopsy procedures.

Biopsy, Needle↗

Sonographic needle guidance in cholangiography in children.

PURPOSE: To evaluate feasibility and benefits of sonographic guidance of percutaneous transhepatic cholangiography (PTC) in children with liver transplants. MATERIALS AND METHODS: The authors prospectively followed 24 PTC procedures in 19 pediatric patients (11 females, 8 males; age 3 months to 17 years) randomized to fluoroscopic or sonographic guidance. The number of needle passes, the contrast material dose, fluoroscopy time, and procedure time for each procedure were recorded. All patients were transplant recipients-six whole and 13 reduced-size grafts. Cases were randomly assigned to two groups: group I, fluoroscopically guided PTC (12 procedures); group II, sonographically guided PTC (12 procedures). RESULTS: The technical success rate was 92% (11 of 12) for each group. In group I, there were two procedure-related complications: postprocedural fever caused by biliary to portal vein fistula, and peritoneal bleeding requiring surgery. In group II, there were no procedure-related complications. A mean of 8.2 +/- 3.7 needle passes were required in group I compared to only 2.0 +/- 1.3 in group II (P < .0001). A mean contrast material dose of 19.5 mL +/- 13.4 was required in group I compared to only 2.5 mL +/- 1.9 in group II (P < .001). A mean procedure time of 15.7 minutes +/- 7.4 was required in group I compared to only 6.1 minutes +/- 4.5 in group II (P < .001). A mean fluoroscopy time of 10.4 minutes +/- 5.0 was required in group I compared to only 1.0 minutes +/- 0.7 in group II (P < .0001). CONCLUSION: In pediatric patients who have undergone liver transplantation, sonographic guidance significantly decreases the number of needle passes, contrast material dose, and fluoroscopy time required for PTC.

Child, Preschool↗

Intravascular MR-monitored balloon angioplasty: an in vivo feasibility study.

PURPOSE: To develop a new method for monitoring balloon angioplasty by using an intravascular magnetic resonance (MR) imaging technique. MATERIALS AND METHODS: Nine New Zealand White rabbits were used: seven for technique refinement, including surgery, device insertion, stenosis creation, and MR protocol development; and two for the final MR imaging of the balloon angioplasty. The in vivo experimental method involved insertion of a catheter antenna and a balloon catheter, via femoral arteriotomies bilaterally, into the target site of the upper abdominal aorta, where a stenosis was artificially created by binding a plastic cable tie. Then, the entire process of the dilation of the stenosis with balloon inflation was monitored under MR fluoroscopy. RESULTS: Catheter insertions were successful, and a 5-mm-long stenosis of the aorta was produced in all nine rabbits. Eight complete balloon angioplasty procedures were satisfactorily monitored and recorded, showing clearly the stenosis of the aorta at the beginning of the procedure, the dilation of the stenosis during the balloon inflation, and the complete opening of the stenosis after balloon dilation. CONCLUSION: Preliminary results of in vivo balloon angioplasty monitored with intravascular MR imaging are presented. MR fluoroscopy, based on the intravascular MR imaging technique, may represent a potential alternative to x-ray fluoroscopy for guiding interventional treatment of cardiovascular diseases.

Angioplasty, Balloon↗

Vertebroplasty: clinical experience and follow-up results.

This study was undertaken to report the clinical experience with percutaneous minimal invasive vertebroplasty using polymethyl-methacrylcate (PMMA) for a consecutive group of patients. Over the period of the last 4 years, 40 patients were treated at 68 vertebral segment levels with the intention to relieve pain related to vertebral body lesions. Reduced vertebral body height and destruction of the posterior vertebral wall were not considered to be exclusion criterias. The vertebroplasty procedure was performed under general anesthesia and in prone position with imaging control using mostly biplane DSA fluoroscopic guidance, and rarely with single-plane mobile DSA combined with computed tomographic guidance. Unilateral, but more frequently bilateral, transpedicular introduction of a 2-3-mm OD needle was followed by an injection of polymethyl-methacrylcate (PMMA). PMMA preparation involved a diluted mixture (20 mL powder for 5 mL liquid) allowing for an extended polymerization time of up to 8 min. The PMMA was mixed with metallic powder to enhance its radio-opacity. Before PMMA injection, a vertebral phlebography was obtained to evaluate the filling pattern and identify sites of potential PMMA leakage. Injection of opacified PMMA was performed under continuous visual control with fluoroscopy to obtain adequate filling and to avoid important PMMA leakage. Clinical follow-up involved an evaluation using a questionnaire for assessment of pain, pain medication, and mobility. One to six levels were treated in one to three treatment sessions for patients with metastatic, osteoporotic, and hemangiomatous lesions of the vertebral bodies who presented with pain. The results observed matched those reported previously with a success rate of approximately 80% and a complication rate below 6% per treated level. Treatment failure and complications observed were related to leakage, insufficient pretreatment evaluation, anesthesia, or patient position during treatment. Image guidance with fluoroscopy was efficient both for precise transpedicular approach and PMMA implantation control. Vertebroplasty is very efficient for treatment of pain. Treatment failure was mostly related to insufficient pretreatment clinical evaluation, and complication due to excessive PMMA volume injection. Control of PMMA volume seems to be the most critical point for avoiding complications. A good fluoroscopy control is therefore mandatory.

Adult↗

Reduction of radiation exposure in the cardiac electrophysiology laboratory.

The purpose of this study was to determine the effects of various protective measures on patient and operator radiation dose levels in catheter ablation procedures. Catheter ablation procedures are associated with significant radiation levels. The patient's skin and operator radiation levels were measured (1) at baseline, (2) after primary beam filtration by 0.3-mm copper sheet and 2-mm aluminium plate and implementation of the LocaLisa system, and (3) after reduction of the left anterior oblique fluoroscopic pulse rate and installation of a lead glass screen. Additionally, a comparative analysis of radiation exposure levels was performed in the seven Dutch catheter ablation centers. Filtration of both primary beams resulted in a more than two-fold reduction in patient skin dose. Together with the LocaLisa system, this resulted in a six-fold reduction in patient and operator dose. As expected, lowering of the left anterior oblique pulse rate from 25 to 12.5 Hz reduced the corresponding patient skin dose with a factor 2 while the lead-glass protection caused an extra factor 2 reduction for the operator. Large differences were observed between fluoroscopy systems used for catheter ablation in the Netherlands. Depending on patient body mass and fluoroscopy system, patient skin dose varied between 0.2 and 8.4 Gy/hour. Proper measures may allow for a significant reduction of patient and operator radiation exposure in catheter ablation procedures. The large influence of body mass and equipment on patient's skin dose requires a more direct monitoring of skin dose than total fluoroscopy time.

Catheter Ablation↗

Radiation exposure during radiofrequency catheter ablation for atrial fibrillation.

RF catheter ablation of paroxysmal atrial fibrillation (PAF) is associated with prolonged fluoroscopy. The procedural duration and fluoroscopic exposure to patients and medical staff were recorded and compared among 43 ablation procedures for PAF, 20 for common atrial flutter, and 16 for accessory pathways. Patient radiation exposure was measured by dosimeters placed over the xyphoid, while that of physicians and nurses was measured by dosimeters placed outside and inside the lead apron. The mean fluoroscopy time was 57 +/- 30 minutes for PAF, 20 +/- 10 minutes for common flutter, and 22 +/- 21 minutes for accessory pathway ablation. The patient median radiation exposure was 1110 microSv for PAF, compared with 500 microSv for common flutter and 560 microSv for accessory pathway ablation (P < 0.01). The median radiation exposure to physician and nurse inside the lead apron were, respectively, 2 microSv and 3 microSv for PAF, 1 microSv and 2 microSv for common flutter, and < 0.5 microSv and 3 microSv for accessory pathway ablations. RF catheter ablation for PAF was associated with prolonged fluoroscopy times and a twofold higher radiation exposure to the patient and physician compared with other ablation procedures. Assuming 300 procedures/year, radiation exposure to the medical staff was below the upper recommended annual dose limit.

Atrial Fibrillation↗