Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compression Algorithms”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Adjunctive treatment of decompression illness with a non-steroidal anti-inflammatory drug (tenoxicam) reduces compression requirement.

We report a randomized trial examining adjunctive administration of the NSAID, tenoxicam, to divers suffering with DCI. 180 subjects were graded for severity on admission and randomized according to a stratified random number schedule. Subjects were recompressed and treatment continued daily until symptom stabilization or complete resolution. Tenoxicam 20 mg or a placebo preparation was administered at the first air break during the initial recompression and continued daily for seven days. The subjects were assessed using a recovery status score at the completion of treatment and at 4-6 weeks. The proportion of patients with mild residual symptoms at discharge and final follow-up was not significantly different (discharge placebo 30% versus tenoxicam 37%, P=0.41; six weeks placebo 20% versus tenoxicam 17%, P=0.58). There was a significant reduction in the number of treatments required to achieve discharge (median treatments placebo 3, tenoxicam 2, P=0.01). 61% of patients in the tenoxicam group required less than 3 compressions, versus 40% in the placebo group (P=0.01, RRR 33 % [95%CI 9%-56%], NNT=5 [95%CI 3-18]). There was no evidence of increased complications of treatment in the tenoxicam group. When given this NSAID, patients with DCI require fewer hyperbaric oxygen (HBO2) sessions to achieve a standard clinical end-point and there is likely to be an associated cost saving.

Adult↗

Auditory brainstem response versus magnetic resonance imaging for the evaluation of asymmetric sensorineural hearing loss.

OBJECTIVES/HYPOTHESIS: Auditory brainstem response (ABR) testing and magnetic resonance imaging (MRI) are compared for the evaluation of patients with asymmetric sensorineural hearing loss (SNHL). MRI with gadolinium administration is the current gold standard for identifying retrocochlear lesions causing asymmetric SNHL. The study seeks to determine the sensitivity and specificity of ABR in screening for possible retrocochlear pathology. Most important among SNHL etiologies are neoplastic lesions such as vestibular schwannomas, cerebellopontine angle (CPA) tumors, as well as multiple sclerosis, stroke, or other rare nonneoplastic causes. The study results will allow the author to recommend a screening algorithm for patients with asymmetric SNHL. STUDY DESIGN: The study is a multi-institutional, institutional review board approved, prospective, nonrandomized comparison of ABR and MRI for the evaluation of patients with asymmetric SNHL. METHODS: Three hundred twelve patients (between the ages of 18 and 87) with asymmetric SNHL completed the study. Asymmetric SNHL was defined as 15 dB or greater asymmetry in two or more frequencies or 15% or more asymmetry in speech discrimination scores (SDS). These patients prospectively underwent both ABR and MRI. The ABR and MRI were interpreted independently in a blinded fashion. In addition to the ABR and MRI results, a variety of clinical and demographic data were collected. RESULTS: Thirty-one (9.94%) patients of the study population of 312 were found on MRI to have lesions causing their SNHL. Of the 31 patients with causative lesions on MRI there were 24 vestibular schwannomas, 2 glomus jugulare tumors, 2 ectatic basilar arteries with brainstem compression, 1 petrous apex cholesterol granuloma, 1 case of possible demyelinating disease, and 1 parietal lobe mass. Twenty-two of the 31 patients had abnormal ABRs, whereas 9 patients (7 with small vestibular schwannomas) had normal ABRs. This gives an overall false-negative rate for ABR of 29%. The false-positive rate was found to be 76.84%. Sensitivity of ABR as a screening test was 71%, and specificity was 74%. CONCLUSIONS: Ten percent of patients with asymmetric SNHL (by this study's criteria) are likely to have causative lesions found on MRI. Although the recently reported annual incidence of vestibular schwannoma in the general population is 0.00124%, for patients with asymmetric SNHL in this study, the incidence was 7.7% (nearly 4 orders of magnitude higher). ABR has been demonstrated to have low sensitivity and specificity in the evaluation of these patients and cannot be relied on as a screening test for patients with asymmetric SNHL. Keeping the use of MRI conditional on the results of ABR will annually result in missed or delayed diagnosis of causative lesions in 29 patients per 1,000 screened. The author recommends abandoning ABR as a screening test for asymmetric SNHL and adoption of a focused MRI protocol as the screening test of choice (within certain guidelines).

Adolescent↗

Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data.

A number of algorithms have been proposed to model the adaptive behavior of bone under load. However, the predictions of several models have neither been compared nor have they been systematically related to in vivo data. To this end, the stress states of loaded implant-bone interfaces were analyzed before and after osseointegration using finite element (FE) techniques. In a preliminary step, an FE mesh of a cylindrical implant encased in a cancellous core surrounded by a cortical layer was constructed, and the stresses and strains that developed at the interface were determined. The implant was loaded with 100 N vertical and 30 N lateral loads. Using this structure, the peak compressive and tensile stresses were determined. Then bone remodeling predictions were assessed using three different models: von Mises equivalent strain, strain energy density and effective stress. Finally, a systematic search of the literature was conducted to relate the numerical predictions to existing in vivo data. The FE simulations led to the following conclusions: (1) calculated compressive stresses were lower than the ultimate compressive stresses of cortical and cancellous bone. (2) Calculated tensile stresses were generally superior to experimental data on the tensile strength of the bone-implant interface. (3) With one exception, the predictions of all models were homogeneously grouped on the stimulus scales. (4) The predictions of the models as to bone gain or loss were not consistent and at times contradictory. It is hypothesized that this effect is linked to a lazy zone that is too narrow. With respect to the application of the numerical models to in vivo data, peak strains and strain energy densities were consistent with in vivo data. No in vivo data were found that supported effective stress as a stimulus.

Adaptation, Physiological↗

Computational modeling of healing: an application of the material force method.

The basic aim of the present contribution is the qualitative simulation of healing phenomena typically encountered in hard and soft tissue mechanics. The mechanical framework is provided by the theory of open system thermodynamics, which will be formulated in the spatial as well as in the material motion context. While the former typically aims at deriving the density and the spatial motion deformation field in response to given spatial forces, the latter will be applied to determine the material forces in response to a given density and material deformation field. We derive a general computational framework within the finite element context that will serve to evaluate both the spatial and the material motion problem. However, once the spatial motion problem has been solved, the solution of the material motion problem represents a mere post-processing step and is thus extremely cheap from a computational point of view. The underlying algorithm will be elaborated systematically by means of two prototype geometries subjected to three different representative loading scenarios, tension, torsion, and bending. Particular focus will be dedicated to the discussion of the additional information provided by the material force method. Since the discrete material node point forces typically point in the direction of potential material deposition, they can be interpreted as a driving force for the healing mechanism.

Animals↗

Elasticity reconstruction for ultrasound elastography using a radial compression: an inverse approach.

To reduce the inherent mechanical artifacts in the strain images, many groups have investigated solutions to the inverse problem in elastography. However, in prostate elastography or intravascular elastography where the compression direction is radial, the inverse problem has not been studied thoroughly. In this paper, an iterative approach is proposed to reconstruct tissue elasticity for ultrasound elastography using a radial compression. The method is based upon the stress-strain relations in the polar coordinates. Computer simulations in an intravascular model are performed to illustrate the feasibility of this method in reducing the mechanical artifacts of the strain images. The reconstructed elasticity error and the contrast-transfer efficiency (CTE) as a function of the iteration number show that the inverse approach converges with a few iterations.

Algorithms↗

Frequency of venous thromboembolism in low to moderate risk long distance air travellers: the New Zealand Air Traveller's Thrombosis (NZATT) study.

BACKGROUND: The frequency and role of risk factors for venous thromboembolism related to air travel is uncertain. We aimed to establish the frequency of this disorder in a group of long distance air travellers and to investigate the role of potential risk factors. METHODS: We designed a prospective study into which we recruited individuals aged between 18 and 70 years, travelling for 4 h or more by aircraft. D-dimer measurement was done before and after travel. Participants with a negative D-dimer (<500 ng/L) before travel were included in the study. Those who became D-dimer positive or developed high clinical probability symptoms during the 3 months after travel were investigated with bilateral compression ultrasonography and CT pulmonary angiography. Suspected clinical and thrombophilic risk factors, and use of prophylactic measures, were assessed. FINDINGS: 1000 individuals were recruited, with 878 meeting inclusion criteria and completing the study. All participants travelled at least 10 h, with a mean total duration of air travel of 39 h (SD 12.5). 112 patients underwent radiological assessment on return. Frequency of venous thromboembolism associated with travel was 1.0% (9/878, 95% CI 0.5-1.9), which included four cases of pulmonary embolism and five of deep venous thrombosis. Six patients with venous thromboembolism had pre-existing clinical risk factors, two had a recognised thrombophilic risk factor, two travelled exclusively in business class, five used aspirin, and four wore compression stockings. INTERPRETATION: Our results suggest an association between multiple long distance air flights and venous thromboembolism, even in individuals at low to moderate risk. The role of traditional risk factors and prophylactic measures in air travel-related venous thromboembolism needs further investigation.

Adolescent↗

Wavelet compression in medical terahertz pulsed imaging.

This paper concerns the robustness of discrete wavelet transform (DWT) compression in terahertz pulsed imaging (TPI). TPI datasets consist of terahertz time-domain series which are sampled at each 'pixel' of the image, leading to file sizes which are typically of the order of several megabytes (MB) per image. This makes efficient compression highly desirable for both transmission and storage. However, since the data may be required for diagnostic purposes it is essential that no relevant information is lost or artefacts introduced. We show that for a nylon step wedge the estimates of refractive index and absorption coefficients are not significantly altered when the terahertz data are reconstructed from only 20% of DWT coefficients.

Algorithms↗

A segmentation-based lossless image coding method for high-resolution medical image compression.

Lossless compression techniques are essential in archival and communication of medical images. In this paper, a new segmentation-based lossless image coding (SLIC) method is proposed, which is based on a simple but efficient region growing procedure. The embedded region growing procedure produces an adaptive scanning pattern for the image with the help of a very-few-bits-needed discontinuity index map. Along with this scanning pattern, an error image data part with a very small dynamic range is generated. Both the error image data and the discontinuity index map data parts are then encoded by the Joint Bi-level Image experts Group (JBIG) method. The SLIC method resulted in, on the average, lossless compression to about 1.6 h/pixel from 8 b, and to about 2.9 h/pixel from 10 b with a database of ten high-resolution digitized chest and breast images. In comparison with direct coding by JBIG, Joint Photographic Experts Group (JPEG), hierarchical interpolation (HINT), and two-dimensional Burg Prediction plus Huffman error coding methods, the SLIC method performed better by 4% to 28% on the database used.

Algorithms↗

The effect on the fatigue strength of bone cement of adding sodium fluoride.

New bone cements that include several additives are currently being investigated and tested. One such additive is sodium fluoride (NaF), which promotes bone formation, facilitating implant integration and success. The influence of NaF on the fatigue performance of the cement as used in biomedical applications was tested in this paper. In fact fatigue failure of the cement mantle is a major factor limiting the longevity of a cemented implant. An experimental bone cement with added NaF (12 wt%) was investigated. The fatigue strength of the novel bone cement was evaluated in comparison with the cement without additives; fatigue tests were conducted according to current standards. The load levels were arranged based on a validated, statistically based optimization algorithm. The curve of stress against number of load cycles and the endurance limit were obtained and compared for both formulations. The results showed that the addition of NaF (12 wt%) to polymethylmethacrylate (PMMA) bone cement does not affect the fatigue resistance of the material. Sodium fluoride can safely be added to the bone cement without altering the fatigue performance of the PMMA bone cement.

Compressive Strength↗

Direct evaluation of erythrocyte aggregability in human, sheep and cow blood samples with a computerized image analysis.

The non-Newtonian properties of blood are caused by the unique properties of red blood cells to aggregate and to deform. Aggregation mechanism of erythrocytes contributes significantly to blood viscosity. Techniques for the assessment of red cell aggregability have major implications for medical practice. A number of techniques based on various principles have been proposed by many researches. However, as yet, none of these techniques have been applied on a wide basis. The aim of the present paper is to determine red cell aggregability in sheep, cow and human blood samples. The red cells remain in the their natural environment (their own blood plasma). First, we had to transform an IBM-PC computer into an Image Acquisition System, so we designed a frame-grabber and the soft driver necessary to assure the image acquisition taken by the TV camera by means of the microscope. These images are digitized, transformed in a standard format BMP and can be compressed and stored or processed. The entire system software is written in C++ assembly language. To evaluate the aggregability index in the blood sample was determined the total area occupied by all automatically detected erythrocytes (Stot) and the overall area occupied by the aggregated erythrocytes (Saggreg). . EAI = (Saggreg/Stot) x 100%; EAI shows the tendency of red blood cell to form aggregates.

Algorithms↗

Influence of methacrylic acid and hydroxypropylmethyl cellulose on the tablet properties and in vitro release of dextromethorphan hydrobromide.

The release of dextromethorphan hydrobromide from matrices containing hydroxypropylmethyl cellulose (HPMC K100LV) and methacrylic acid copolymer (Eudragit L100-55) has been evaluated at different ratios of the polymers. The physicochemical properties (including weight, thickness, crushing strengh, friability and disintegration time) were also determined at 1000, 2000 and 4000 p compression forces. No significant differences in weight uniformity and thickness values were observed between the different formulations. The crushing strength of the tablets increased with increasing compression force and it reached a constant level at 4000 p. The formulations containing only HPMC K100LV resulted in an extended release pattern, however, Eudragit L100-55 alone could not effectively prolong the drug release. A combination of HPMC K100LV and Eudragit L100-55 in a 1:1 ratio at the 40% level provided an almost similar drug release profile than the marketed product.

Acrylic Resins↗

Ultrasound palpation sensor for tissue thickness and elasticity measurement--assessment of transverse carpal ligament.

Palpation is a traditional diagnostic procedure for health care professionals to use their fingers to touch and feel the body soft tissues. It is a common clinical approach, though it is rather subjective and qualitative and the palpation results may vary among different people. Tissue ultrasound palpation sensor (TUPS) provides a feasible solution that makes the palpation of soft tissues not subjective feeling any more. It is comprised of an ultrasound transducer together with a load cell to form the finger-sized probe. The probe is used to push against the soft tissue surface to measure the thickness and elasticity of the soft tissues. TUPS has been successfully applied to the assessment of various human tissues. Recently, we have improved TUPS, which can now be linked to personal computer (PC) via universal serial bus (USB) and provide a better user-interface. The information of ultrasound signal and indentation force is displayed on PC in real time during measurement. In this paper, we introduce the recent application of TUPS for the assessment of the transverse carpal ligament. The tissues at the carpal tunnel regions of five normal male subjects were tested using TUPS. The results showed that the average thickness of the tissues covering the carpal tunnel ligament and the tunnel region was 7.98+/-1.05 mm and 9.59+/-1.12 mm, respectively. Under a compression force of 20 N applied by a cylindrical ultrasound indentor with a diameter of 9 mm, the stiffness of the soft tissue layer and the tunnel region was 6.72+/-2.10 N/mm and 15.63+/-8.42 N/mm, respectively. It is expected that TUPS can be a potential tool for non-invasive assessment of carpal tunnel syndrome.

Algorithms↗

Towards an acoustic model-based poroelastic imaging method: I. Theoretical foundation.

The ultrasonic measurement and imaging of tissue elasticity is currently under wide investigation and development as a clinical tool for the assessment of a broad range of diseases, but little account in this field has yet been taken of the fact that soft tissue is porous and contains mobile fluid. The ability to squeeze fluid out of tissue may have implications for conventional elasticity imaging, and may present opportunities for new investigative tools. When a homogeneous, isotropic, fluid-saturated poroelastic material with a linearly elastic solid phase and incompressible solid and fluid constituents is subjected to stress, the behaviour of the induced internal strain field is influenced by three material constants: the Young's modulus (E(s)) and Poisson's ratio (nu(s)) of the solid matrix and the permeability (k) of the solid matrix to the pore fluid. New analytical expressions were derived and used to model the time-dependent behaviour of the strain field inside simulated homogeneous cylindrical samples of such a poroelastic material undergoing sustained unconfined compression. A model-based reconstruction technique was developed to produce images of parameters related to the poroelastic material constants (E(s), nu(s), k) from a comparison of the measured and predicted time-dependent spatially varying radial strain. Tests of the method using simulated noisy strain data showed that it is capable of producing three unique parametric images: an image of the Poisson's ratio of the solid matrix, an image of the axial strain (which was not time-dependent subsequent to the application of the compression) and an image representing the product of the aggregate modulus E(s)(1-nu(s))/(1+nu(s))(1-2nu(s)) of the solid matrix and the permeability of the solid matrix to the pore fluid. The analytical expressions were further used to numerically validate a finite element model and to clarify previous work on poroelastography.

Acoustics↗

Effects of nonpolar solutes on the thermodynamic response functions of aqueous mixtures.

We investigate the effect of adding nonpolar solutes at atmospheric pressure on water's temperature of maximum density, isothermal compressibility, and isobaric heat capacity, using a statistical mechanical model of water solutions [H. S. Ashbaugh, T. M. Truskett, and P. G. Debenedetti, J. Chem. Phys. 116, 2907 (2002)]. We find that the temperature of maximum density increases with solute hydrophobicity, as characterized by its size, and decreases with its van der Waals attractive parameter a, in agreement with experiment. We predict similar trends for the addition of solutes on the isothermal compressibility and isobaric heat capacity: solute hydrophobicity causes an upward shift in water's anomalies, whereas dispersive interactions as measured by the solute's van der Waals attractive parameter shift the anomalies to lower temperatures. The locus along which the competing contributions of solute size sigma and interaction strength a to the shift in water's response functions balance each other obeys the scaling relationship sigma6 approximately a.

Algorithms↗

Application of artificial neural networks (ANN) in the development of solid dosage forms.

The application of ANN in pharmaceutical development has been assessed using theoretical as well as typical pharmaceutical technology examples. The aim was to quantitatively describe the achieved data fitting and predicting abilities of the models developed with a view to using ANN in the development of solid dosage forms. The comparison between the ANN and a traditional statistical (i.e., response surface methodology, RSM) modeling technique was carried out using the squared correlation coefficient R2. Using a highly nonlinear arbitrary function the ANN models showed better fitting (R2 = 0.931 vs. R2 = 0.424) as well as predicting (R2 = 0.810 vs. R2 = 0.547) abilities. Experimental data from a tablet compression study were fitted using two types of ANN models (i.e., multilayer perceptrons and a hybrid network composed of a self-organising feature map joined to a multilayer perception). The achieved data fitting was comparable for the three methods (MLP R2 = 0.911, SOFM-MLP R2 = 0.850, and RSM R2 = 0.897). ANN methodology represents a promising modeling technique when applied to pharmaceutical technology data sets.

Algorithms↗

Iliofemoral deep vein thrombosis in childhood; developing a management protocol.

OBJECTIVE: To develop an evidence-based protocol for the management of iliofemoral deep vein thrombosis (IDVT) in childhood. METHODS: A search of the literature was undertaken. All publications pertaining to IDVT in childhood were analysed and then categorised according to their level of evidence. Recommendations were then made on the basis of this. RESULTS: The commonest presenting symptoms were pain and swelling in the affected limb (evidence level II). Predisposing risk factors of special significance in children included the recent use of a venous access device, malignancy, prothrombotic disorders, infection, surgery and congenital venous anomalies (evidence level II). The most frequently described imaging modalities were B-mode ultrasonography, duplex, venography, and helical CT (evidence level III). The mainstay of treatment was anticoagulation with LMWH alone or followed by warfarin (evidence level I). Early clot removal through catheter-directed thrombolysis or surgical thrombectomy has been shown to be beneficial (evidence level II/III). There is little evidence for the benefit of early mobilisation and compression therapy in childhood. CONCLUSION: Level I evidence relating to IDVT in childhood is sparse. The possibility of IDVT should be considered when examining a child with a swollen and painful limb. Imaging should be with duplex ultrasound, followed by spiral CT to include assessment of the IVC. A thrombophilia screen should be taken prior to anticoagulation with LMWH (and warfarin). Thrombolysis should be considered in cases of extensive IDVT.

Algorithms↗

Computational study of the self-organization of bidisperse nanoparticles.

We study computationally the self-organization of bidisperse mixtures of thiol-stabilized gold particles in two dimensions through random sequential adsorption (RSA) coupled with the Metropolis algorithm for determining surface diffusion. It was previously shown [Doty et al. Phys. Rev. E 2002, 65, 061503] that ordered lattices of bidisperse particles cannot form with hard sphere interactions. Here we include the effects of interparticle forces. Osmotic and steric interactions provide a repulsive force at close distances, while at longer ranges the van der Waals interaction leads to attraction. Two size ratios (sigma) of 0.375 and 0.577, determined experimentally to form LS (the two-dimensional NaCl analogue) and LS2 (the two-dimensional AlB2 analogue) lattices, were studied. The calculated jamming limits for RSA fall well below the minimum surface coverage necessary for stable ordering as determined by melting simulations. Uniform compression of the particles' positions, as a model of the convection and lateral capillary forces that would be experienced during solvent evaporation, allowed this critical surface coverage to be achieved, and LS lattice formation was observed for sigma = 0.375. No LS2 lattice formation was observed for sigma = 0.577 with compression. The melting coverage of the LS2 lattice far exceeds the coverage observed experimentally and so is not observed.

Adsorption↗

Spinal compression tolerance limits for the design of manual material handling operations in the workplace.

Spinal compression tolerance limits (SCTL) have been widely used by ergonomists in setting work tolerance limits for manual materials handling (MMH) operations. Thus, the effect of personal and experimental factors on spinal compression tolerance limits (SCTL) is reviewed with the aid of regression and correlation analyses performed on data compiled from the published literature. Tables of SCTL from various sources utilizing large number of specimens and personal factors are presented so that they can be accessed by ergonomists easily. Integrated biomechanical guidelines based on SCTL are provided for the design of MMH operations in the workplace. It is suggested that, in order to reduce the probability of MMH injuries, biomechanical tolerance limits should be set at the damage load instead of the load at fracture. The damage load is the weight which causes the first gross signs of damage such as tissue fluid and blood. An algorithm is described to demonstrate the use of a biomechanics approach to the design of MMH operations.

Adult↗