Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Nuclear organization of active and inactive chromatin domains uncovered by chromosome conformation capture-on-chip (4C).

The spatial organization of DNA in the cell nucleus is an emerging key contributor to genomic function. We developed 4C technology (chromosome conformation capture (3C)-on-chip), which allows for an unbiased genome-wide search for DNA loci that contact a given locus in the nuclear space. We demonstrate here that active and inactive genes are engaged in many long-range intrachromosomal interactions and can also form interchromosomal contacts. The active beta-globin locus in fetal liver preferentially contacts transcribed, but not necessarily tissue-specific, loci elsewhere on chromosome 7, whereas the inactive locus in fetal brain contacts different transcriptionally silent loci. A housekeeping gene in a gene-dense region on chromosome 8 forms long-range contacts predominantly with other active gene clusters, both in cis and in trans, and many of these intra- and interchromosomal interactions are conserved between the tissues analyzed. Our data demonstrate that chromosomes fold into areas of active chromatin and areas of inactive chromatin and establish 4C technology as a powerful tool to study nuclear architecture.

Animals↗

Chip and solution detection of DNA hybridization using a luminescent zwitterionic polythiophene derivative.

Electronic polymers in aqueous media may offer bioelectronic detection of biospecific interactions. Here we report a fluorometric DNA hybridization detection method based on non-covalent coupling of DNA to a water-soluble zwitterionic polythiophene derivative. Introduction of a single-stranded oligonucleotide will induce a planar polymer and aggregation of the polymer chains, detected as a decrease of the intensity and a red-shift of the fluorescence. On addition of a complementary oligonucleotide, the intensity of the emitted light is increased and blue-shifted. The detection limit of this method is at present approximately 10(-11) moles. The method is highly sequence specific, and a single-nucleotide mismatch can be detected within five minutes without using any denaturation steps. The interaction with DNA and the optical phenomena persists when the polymer is deposited and patterned on a surface. This offers a novel way to create DNA chips without using covalent attachment of the receptor or labelling of the analyte.

DNA↗

Proteome chips for whole-organism assays.

Over the past 5 years, protein-chip technology has emerged as a useful tool for the study of many kinds of protein interactions and biochemical activities. The construction of Saccharomyces cerevisiae whole-proteome arrays has enabled further studies of such interactions in a proteome-wide context. Here, we explore some of the recent advances that have been made at the '-omic' level using protein microarrays.

Animals↗

The use of bone-chip grafts fixed with absorbable bone sealant (Absele).

In this study we have investigated the use of bone-chip grafts which were fixed by Absele. In the study 33 adult guinea-pigs were used. Bone grafts for cervical intervertebral fusions were carried out. At the end of the sixth week the bones were examined histopathologically. Both in the control fusion group and in the experiment group the bone grafts were found to be in good condition, but in the free graft group some bone fragments were found in muscle tissue. There was no evidence of foreign body reaction.

Absorption↗

Yeast homolog of human SAG/ROC2/Rbx2/Hrt2 is essential for cell growth, but not for germination: chip profiling implicates its role in cell cycle regulation.

In an attempt to understand the signaling pathway mediating redox-induced apoptosis, we cloned SAG, an evolutionarily conserved zinc RING finger gene that, when overexpressed, protects cells from apoptosis induced by redox agents. Here we report functional characterization of SAG by the use of yeast genetics approach. Targeted disruption of ySAG, yeast homolog of human SAG, and subsequent tetrad analysis revealed that ySAG is required for yeast viability. Complementation experiment showed that the lethal phenotype induced by the ySAG deletion is fully rescued by wildtype SAG, but not by several hSAG mutants. Complementation experiment has also confirmed that ySAG is essential for normal vegetative growth, rather than being required for sporulation. Furthermore, cell death induced by SAG deletion was accompanied by cell enlargement and abnormal cell cycle profiling with an increased DNA content. Importantly, SAG was found to be the second family member of Rbx (RING box protein) or ROC (Regulator of cullins) or Hrt that is a component of SCF E3 ubiquitin ligase. Indeed, like ROC1/Rbx1/Hrt1, SAG binds to Cul1 and SAG-Cul1 complex has ubiquitin ligase activity to promote poly-ubiquitination of E2/Cdc34. This ligase activity is required for complementation of death phenotype induced by ySAG disruption. Finally, chip profiling of the entire yeast genome revealed induction of several G1/S as well as G2/M checkpoint control genes upon SAG withdrawal. Thus, SAG appears to control cell cycle progression in yeast by promoting ubiquitination and degradation of cell cycle regulatory proteins. Oncogene (2000) 19, 2855 - 2866

Carrier Proteins↗

Capillary electrophoresis system with flow injection sample introduction and chemiluminescence detection on a chip platform.

A capillary electrophoresis (CE) system with chemiluminescence (CL) detection was combined with flow injection (FI) sample introduction on a chip platform. A falling-drop interface was applied to perform FI split-flow sample introduction while achieving electrical isolation from the CE high voltage. A tubular reservoir at the capillary outlet served as both the CL reaction and detection cell for the luminol-peroxide-metallic ion chemiluminescent reaction, with the luminol included in the separation buffer and CL reagent H2O2 continuously introduced into the outlet reservoir. An optical fiber was positioned within the outlet reservoir directly opposite, and 300 microns away from, the capillary outlet for collecting and transferring the generated CL to the PMT. The peak height signals and the separation efficiency were almost independent of the reagent flow-rate, making the system a robust one. The performance of the system was illustrated by the separation of Co(II) and Cu(II), achieving baseline separation in 60 s. Detection limits (3 sigma) were 1.25 x 10(-8) and 2.3 x 10(-6) mol dm-3 for Co(II) and Cu(II), respectively. Peak height precision was 1.9% RSD (n = 9) at the 10(-7) mol dm-3 Co level.

Journal Article↗

Integration of a wet analysis system on a glass chip: determination of Co(ii) as 2-nitroso-1-naphthol chelates by solvent extraction and thermal lens microscopy.

The integration of a wet analysis system on a glass chip was demonstrated and determination of Co(II) was performed using this system. The Co(II) was extracted into m-xylene from aqueous solution as 2-nitroso-1-naphthol chelates, and colorimetric determination of the m-xylene phase was applied by a thermal lens microscope. The integration of the chemical operation procedures shown here leads to a considerable reduction in analyzing time. The time for extraction in the integrated system, 10 min, was about tenfold shorter than a conventional system using a separatory funnel and mechanical shaker. Moreover, troublesome operations such as phase separation necessary for the conventional system could be omitted. The determination of Co(II) in the range 2 x 10(-7)-1 x 10(-8) M, which was estimated to be 0.072-1.44 zmol, was achieved.

Journal Article↗

A novel type of microscopic size chip based on double-stranded nucleic acids.

The double-stranded molecules of nucleic acids (NA) of B- and A-families fixed in the structure of cholesteric liquid-crystalline dispersions, formed as a result of phase exclusion of these molecules from polymer-containing solution, have been used as 'building blocks' for the molecular design. Using the formation of polymeric chelate bridges between NA molecules, three-dimensional structures consisting of alternating NA, anthracycline and copper ions, were created. The formation of the polymeric chelate bridges allows one to stabilize the initial spatial mode of ordering of neighboring NA molecules in a form of so-called 'molecular constructions', immobilize these constructions onto supporting film and evaluate their sizes and shape. The creation of NA molecular constructions is accompanied by an 'extra-increase' in the amplitude of the bands in the CD spectra, despite the initial sense of cholesteric twisting characteristic of liquid-crystalline dispersions. Destroying of polymeric chelate bridges between NA molecules by action of biologically relevant compounds results in disintegration of NA liquid-crystalline molecular constructions. Three-dimensional NA molecular construction can be used as a microscopic size multifunctional chemical unit (chip) for biological or chemical needs.

Circular Dichroism↗

On-chip culture system for observation of isolated individual cells.

To investigate the properties of isolated single cells with their environment, we developed the differential analysis method for single cells using an on-chip microculture system. The advantages of the system are, (i). continuous cultivation of a series of isolated single cells or a group of cells under contamination free conditions, (ii). continuous observation and comparison of those cells with 0.2 microm spatial resolution by a phase-contrast/fluorescent microscopy system with digital image processing. The core of the system is an n x n (n = 20-50) array of chambers, where each is 20-70 microm in diameter and 5-30 microm deep holes etched into a biotin-coated 0.17 mm thick glass slide. The biotin-coated glass slide is covered with the streptavidin coated cellulose semipermeable membrane, which is fixed on the surface of the glass slide by streptavidin-biotin attachment, separating those holes from the nutrient medium circulating through a 'cover chamber' above. A single cell or group of cells can thus be isolated from environment perfused with the same medium, and the medium in each chamber can be changed within the diffusion time (<1/30 s). In addition, the microchamber volumes of specific cells or cell groups can be controlled by the sizes of the chambers. By using this system we found that the length of isolated Escherichia coli increased at 0.06 microm min(-1) between cell divisions regardless of the chamber volume, and that the cell concentration reached 10(12) cells ml(-1) under contamination free conditions. The system is thus particularly useful for one cell level analysis because the direct descendants of single cells can be cultured and compared in the isolated microchambers, and the physical properties of the cells in each microchamber can be continuously observed and compared.

Buffers↗

Glow discharge in microfluidic chips for visible analog computing.

Here we present a novel visible analog computing approach for solving a wide class of shortest path problems. Using a microfluidic chip for computation, based on the lighting up of a glow discharge, the solution to maze search problems, the solution of a network shortest path and k-shortest paths problems and the practical application of finding the shortest paths between several landmarks from a street map are presented. The solution and visible display (in real time) for these problems shows only a small difference in practical problem solving time among problems with varying differences in size.

Journal Article↗

Generation of concentration gradient by controlled flow distribution and diffusive mixing in a microfluidic chip.

We have developed a simple method to generate a concentration gradient in a microfluidic device. This method is based on the combination of controlled fluid distribution at each intersection of a microfluidic network by liquid pressure and subsequent diffusion between laminas in the downstream microchannel. A fluid dynamic model taking into account the diffusion coefficient was established to simulate the on-chip flow distribution and diffusion. Concentration gradients along a distance of a few hundred micrometers were generated in a series of microchannels. The gradients could be varied by carefully regulating the liquid pressure applied to the sample injection vials. The observed concentration gradients of fluorescent dyes generated on the microfluidic channel are consistent with the theoretically predicted results. The microfluidic design described in this study may provide a new tool for applications based on concentration gradients, including many biological and chemical analyses such as cellular reaction monitoring and drug screening.

Journal Article↗

Chemiluminescence biosensor chip based on a microreactor using carrier air flow for determination of uric acid in human serum.

A chemiluminescence biosensor on a chip coupled to a microfluidic system and a microreactor is described in this paper. The chemiluminescence biosensor measured 25 x 75 x 6.5 mm in dimension, and was readily produced in an analytical laboratory. The sol-gel method is introduced to co-immobilize horseradish peroxidase (HRP) and luminol in the microreactor, and to immobilize uricase in the enzymatic reactor. The main characteristic of the biosensor was to introduce air as the carrier flow instead of the more common solution carrier for the first time. The uric acid was determined by a chemiluminescent (CL) reaction between the hydrogen peroxide produced from the enzymatic reactor and luminol under the catalysis of HRP in the microreactor. The linear range of the uric acid concentration was 1 to 100 mg L(-1) and the detection limit was 0.1 mg L(-1) (3sigma).

Biosensing Techniques↗

Bidirectional isotachophoresis on a planar chip with integrated conductivity detection.

The use of a miniaturised planar separation device with integrated conductivity detection for performing bidirectional isotachophoresis (ITP) is described. The chips were produced in poly(methyl methacrylate) (PMMA) using a milling procedure. To enable bidirectional ITP the devices were designed to inject samples into the centre of the section channel and incorporated two integrated on-column conductivity detectors, positioned at opposite ends of this channel. When used with a hydrodynamic sample transport system the devices were used for the analysis of a range of small ions: NH4+; Na+; Mg2+; Ca2+; Li+; NO3-; ClO4-; SO4(2-); F-. Results sucessfully achieved included the simultaneous separation of three anions and three cations.

Journal Article↗

Measurement of density and chemical concentration using a microfluidic chip.

A new microfluidic product for measuring fluid density, specific gravity and chemical concentration has been developed. At the core of this lab-on-a-chip sensor is a vacuum-sealed resonating silicon microtube. Measurements can be made with under a microliter of sample fluid, which is over 1000x less than is conventionally required. Since the product is MEMS-based the overall system size is a fraction of conventional density meters and it weighs much less than the traditional desk-top, temperature controlled, density meters. The syringe or pipette loaded system includes a dynamic temperature control system that operates between 0 degree C and 90 degree C with an accuracy of less than 0.01 degree C. Density measurement accuracies of 4 to 5 digits have been observed with aqueous solutions. Measurement examples and applications will be discussed.

Equipment Design↗

Soxhlet extraction of acrylamide from potato chips.

The problem of complete extraction of acrylamide from potato chips was investigated. A method was developed based on the Soxhlet extraction technique. A defatted sample was extracted continuously with methanol, for 10 days, in a Soxhlet extractor. After about 7 days, a constant concentration of acrylamide was reached. This indicates that all the acrylamide that could be removed from the sample had been extracted. Acrylamide was identified in the extract using GC-MS and scan mode. Total concentration was 14500 microg kg(-1) using GC-FID and standard additions. Complementary determinations, using an external standard (GC-FID and GC-MS) and an internal standard (GC-FID), showed results within +/- 5%. A previously published study, using a static extraction method and GC-MS and LC-MS-MS, showed concentrations of 2287 and 1993 microg kg(-1), respectively. The results are discussed in relation to a recent model and analogous experiments. The extracted amount of acrylamide is affected by several parameters: solvent properties, solvent volume, extraction time, temperature, particle size, and the microstructure of the sample.

Acrylamide↗

Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip.

A microfluidic system was developed for the analysis of single biological cells, with functional integration of cell sampling, single cell loading, docking, lysing, and capillary electrophoretic (CE) separation with laser induced fluorescence (LIF) detection in microfabricated channels of a single glass chip. Channels were 12 microm deep and 48 microm wide, with a simple crossed-channel design. The effective separation channel length was 35 mm. During sampling with a cell suspension (cell population 1.2 x 10(5) cells per mL in physiological salt solution), differential hydrostatic pressure (created by adjusting liquid levels in the four reservoirs) was used to control cell flow exclusively through the channel crossing. Single cell loading into the separation channel was achieved by electrophoretic means by applying a set of potentials at the four reservoirs, counteracting the hydrostatic flow. A special docking (adhering) procedure for the loaded cell was applied before lysis by repeatedly connecting and disconnecting a set of low potentials, allowing precise positioning of the cell within the separation channel. Cell lysis was then effected within 40 ms under an applied CE separation voltage of 1.4 kV (280 V cm(-1)) within the working electrolyte (pH 9.2 borate buffer) without additional lysates. The docked lysing approach reduced dispersion of released intracellular constituents, and significantly improved the reproducibility of CE separations. Glutathione (GSH) was used as a model intracellular component in single human erythrocyte cells. NDA derivatized GSH was detected using LIF. A throughput of 15 samples h(-1), a retention time precision of 2.4% RSD was obtained for 14 consecutively injected cells. The average cellular concentration of GSH in human erythrocytes was found to be 7.2 [times] 10(-4)+/- 3.3 x 10(-4) M (63 +/- 29 amol per cell). The average separation efficiency for GSH in lysed cells was 2.13 x 10(6)+/- 0.4 x 10(6) plates per m, and was about a factor of 5 higher than those obtained with GSH standards using pinched injection.

Electrophoresis, Capillary↗

Integrated polymer chip for two-dimensional capillary gel electrophoresis.

Two-dimensional (2D) gel electrophoresis (GE) is one of the most powerful methods for nucleic acid and protein separation, but generally suffers from high laboratory efforts connected with high analysis costs. Therefore, we herein present the development of a miniaturized 2D capillary GE (CGE) device which allows for an efficient protein separation in analysis times of about 1.5 h. This integrated 2D-CGE chip comprises a first channel for isoelectric focussing (IEF), a second specially designed transfer channel, 300 parallel micro channels, each having a cross section of 50 microm x 50 microm, and buffer reservoirs. The present work discusses fabrication aspects, in particular the combination of different microfabrication technologies, experimental separation performances of isoelectric focussing (IEF) and CGE, and presents computer simulations and first experimental results of protein transfer from the first to the second dimension.

Animals↗