Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CLAMPS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Corticosteroid-mediated modulation of carbachol responsiveness in CA1 pyramidal neurons: a voltage clamp analysis.

Pyramidal neurons in the rat hippocampal CA1 area contain mineralocorticoid (MRs) and glucocorticoid (GRs) receptors for corticosterone. Previous current clamp experiments showed that depolarizations evoked by carbachol (1-3 microM) depend on relative MR/GR occupation: carbachol responses are small with predominant MR-activation and larger when both receptor types are occupied. Multiple K-conductances underlie the carbachol-induced depolarization. In the present study we used the single electrode voltage clamp technique to examine which K-conductances modulated by carbachol are sensitive to corticosteroid treatment in vitro. We observed that 1 microM carbachol significantly reduced the IK,Leak while the IM was hardly affected; carbachol effects on the IK,Leak were significantly reduced under conditions of predominant MR activation compared to simultaneous activation of MRs and GRs. With a higher (10 microM) carbachol dose, steroid modulation of the IK,Leak showed a similar tendency. The amplitude of the IM was largely reduced by 10 microM carbachol but appeared to be not affected by steroid treatment. We conclude that the previously described suppression of the carbachol-induced depolarization with predominant activation MRs is caused by an attenuation of the carbachol action on the IK,Leak.

Adrenal Cortex Hormones↗

Patch-clamp capacitance measurements: new insights into the endocytic uptake of transferrin.

Since its introduction by Neher and Sakmann in 1976 the patch-clamp technique has been extensively used to study processes such as signalling and synaptic transmission, but also for monitoring endo- and exocytosis. Since biological membranes behave like electrical capacitors high-resolution measurements of membrane capacitance allow detection of small changes in membrane surface area that accompany exocytosis and endocytosis. We here describe our recent work on patch-clamp capacitance measurements in stably transfected HeLa cells expressing HFE, the hereditary hemochromatosis gene product, under the control of a tetracycline-sensitive promotor. By means of whole-cell and cell-attached techniques we were able to reveal transferrin-induced decreases in membrane capacitance reflecting increased endocytosis at the single cell level. Moreover, cell-attached recordings revealed significant alterations in the formation of single endocytic vesicles. Time-resolved measurements of cell membrane capacitance provide a new methodological approach to study the endocytic uptake of transferrin and its regulation by HFE, the hereditary hemochromatosis protein.

Cytoplasmic Vesicles↗

A nitric oxide concentration clamp.

We report a new method of generating nitric oxide (NO) that possesses several advantages for experimental use. This method consists of a photolysis chamber where NO is released by illuminating photolabile NO donors with light from a xenon lamp, in conjunction with feedback control. Control of the photolysis light was achieved by selectively gating light projected through a shutter before the light was launched into a light guide that conveyed the light to the photolysis chamber. By gating the light in proportion to a sensor that reported nearly instantaneous concentration from the photolysis chamber, a criterion NO concentration could be achieved, which could be easily adjusted to higher or lower criterion levels. To denote the similarity of this process with the electrophysiological process of voltage clamp, we term this process a concentration "clamp." This development enhances the use of the fiber-optic-based system for NO delivery and should enable the execution of experiments where the in situ concentration of NO is particularly critical, such as in biological preparations.

Feedback↗

Patch-clamp study on membrane properties and transmitter activated currents of rabbit area postrema neurons.

Using the patch-clamp technique in combination wit sliced tissue preparation the membrane properties of newborn rabbit area postrema neurons were investigated. The neurons responded upon depolarization with a fast Na+-current followed by an inactivating and non-inactivating K+-current. GABA-activated currents were investigated resulting in a large C1-(-)conductance, indicating the expression of GABAA-receptors. The expression of glutamate receptor mRNA was studied by in situ hybridization and electrophysiological measurements of these receptors by means of the patch-clamp technique. As a main result it was found that ionotropic glutamate receptors in the area postrema are composed of "flop" variants of the GluA-, GluB- and GluC-subunits.

Animals↗

Correlation of open cell-attached and excised patch clamp techniques.

The excised patch clamp configuration provides a unique technique for some types of single channel analyses, but maintenance of stable, long-lasting preparations may be confounded by rundown and/or rapid loss of seal. Studies were performed on the amiloride-sensitive Na+ channel, located on the apical surface of A6 cells, to determine whether the nystatin-induced open cell-attached patch could serve as an alternative configuration. Compared to excised inside-out patches, stable preparations were achieved more readily with the open cell-attached patch (9% vs. 56% of attempts). In both preparations, the current voltage (I-V) relation was linear, current amplitudes were equal at opposite equivalent clamped voltages, and Erev was zero in symmetrical Na+ solutions, indicating similar Na+ activities on the cytosolic and external surfaces of the patch. Moreover, there was no evidence that nystatin altered channel activity in the patch because slope conductance (3-4pS) and Erev (75 mV), when the bath was perfused with a high K:low Na solution (ENa = 80 mV), were nearly equal in both patch configurations. Our results therefore indicate that the nystatin-induced open cell-attached patch can serve as an alternative approach to the excised inside-out patch when experiments require modulation of univalent ions in the cytosol.

Animals↗

Staphylococcus aureus alpha-toxin-induced pores: channel-like behavior in lipid bilayers and patch clamped cells.

The conductance of pores induced by Staphylococcus aureus alpha-toxin in Lettre cells has been compared to that in bilayers composed of synthetic lipids or Lettre cell membrane constituents. Previously described characteristics of toxin-induced conductance changes in lipid bilayers, namely rectification, voltage-dependent closure, and closure at low pH or in the presence of divalent cations (Menestrina, 1986) are displayed also in bilayers prepared from Lettre cell membranes and in patch clamped Lettre cells. It is concluded that endogenous proteins do not affect the properties of alpha-toxin-induced channels significantly and that the relative lack of ion channels in Lettre cells makes them ideal for studies of pore-forming toxins by the patch clamp technique.

Animals↗

Comparative dose-related time-action profiles of glibenclamide and a new non-sulphonylurea drug, AG-EE 623 ZW, during euglycaemic clamp in healthy subjects.

Insulin and glucose responses to glibenclamide were studied in comparison to a novel non-sulphonylurea drug (AG) by means of the euglycaemic clamp technique. Nine fasting male subjects were connected to a Biostator and 1.75, 3.5 or 7.0 mg glibenclamide or 1.0, 2.0 or 4.0 mg AG were given and blood glucose concentrations were clamped at 10% below basal values. Glucose infusion rates were registered over 10 h after administration of the tablet. Maximal glucose infusion rates after glibenclamide were 40% higher compared to AG (1.75 vs 1.0 mg, 3.5 vs 2.0 mg, 7.0 vs 4.0 mg, respectively) and were reached after 3-3.5 h for all doses. After glibenclamide, area under the glucose infusion curves and maximal incremental serum insulin responses were higher by 25-40% and by 30% compared to AG when low, medium and high doses of each drug were tested. However, a linear dose relationship was obtained for both drugs when the glucose infusion rate was plotted against the area under the insulin curve. In fact, both drugs were equipotent on a molecular weight basis. The hypoglycaemic index of both drugs (integrated glucose infusion rate divided by integrated insulin release) expressed per mumol of drug revealed a dose-dependent and parallel inverse curvilinear relation to increasing doses. This methodological approach allowed us to quantify and compare the metabolic effects of oral hypoglycaemic agents under standardised experimental conditions.

Administration, Oral↗

A simple technique for on-line measurement of contractions of single smooth muscle fibers under current or voltage clamp.

This paper describes a simple technique for routine on-line measurement of length and unloaded, isotonic contractions of single smooth muscle fibers during electrophysiological experiments. The fiber is held by the recording electrode itself, stretched straight in a fast-flowing stream of solution. The video image of the fiber is measured on-line by a simple computer program. Unlike other optical methods of tracking fiber length, the technique does not require a rigid one-dimensional contraction of the fiber. The technique is reliable and easy to use, and readily compatible with current clamp, voltage clamp, and rapid reversible application of neurotransmitters and drugs.

Algorithms↗

The glucose clamp technique for the study of patients with hypoglycemia: insulin resistance as a feature of insulinoma.

Occurrence of hypoglycemia during a prolonged fasting, accompanied by inappropriately high serum insulin levels, is considered a reliable index of the presence of insulinoma. Previous in vitro studies on insulin receptors, and in vivo hyperinsulinemic clamps have shown that patients with insulinoma are insulin resistant. In the present study 10 patients with insulinoma, 6 patients with nontumoral (also called functional or reactive hypoglycemia) hypoglycemia and 6 normal subjects were fasted for 24 h and their blood glucose levels were maintained constant by means of a programmed glucose infusion (isoglycemic glucose clamp) delivered by an artificial pancreas (Biostator). Blood glucose levels were monitored in continum, glucose infused (M) and glucose clearance (MCR) were evaluated at hourly intervals, and serum insulin (IRI) levels were evaluated every 6 h. Blood glucose levels were higher in controls than in patients with insulinoma and in patients with non tumoral hypoglycemia; M, MCR and IRI were progressively higher in controls, in patients with nontumoral hypoglycemia and in patients with insulinoma. The M/I index (M divided by IRI levels, an index of insulin sensitivity) was lower in patients with insulinoma than in other subjects and patients, indicating the existence of insulin resistance. These data indicate that: i) patients with insulinoma require large amounts of glucose to remain isoglycemic during a prolonged fast; ii) insulin resistance is a common feature of insulinoma and can be shown even under near physiologic conditions such as a 24-h fasting. The present study does not clarify whether insulin resistance occurs at the hepatic level or at other, peripheral levels.

Adolescent↗

Distributions-per-level: a means of testing level detectors and models of patch-clamp data.

Level or jump detectors generate the reconstructed time series from a noisy record of patch-clamp current. The reconstructed time series is used to create dwell-time histograms for the kinetic analysis of the Markov model of the investigated ion channel. It is shown here that some additional lines in the software of such a detector can provide a powerful new means of patch-clamp analysis. For each current level that can be recognized by the detector, an array is declared. The new software assigns every data point of the original time series to the array that belongs to the actual state of the detector. From the data sets in these arrays distributions-per-level are generated. Simulated and experimental time series analyzed by Hinkley detectors are used to demonstrate the benefits of these distributions-per-level. First, they can serve as a test of the reliability of jump and level detectors. Second, they can reveal beta distributions as resulting from fast gating that would usually be hidden in the overall amplitude histogram. Probably the most valuable feature is that the malfunctions of the Hinkley detectors turn out to depend on the Markov model of the ion channel. Thus, the errors revealed by the distributions-per-level can be used to distinguish between different putative Markov models of the measured time series.

Algorithms↗

Current oscillations under voltage-clamp conditions: an interplay of series resistance and negative slope conductance.

Using the patch-clamp technique, we observed profound oscillations of the whole-vacuole outward current across the tonoplast of Mesembryanthemum crystallinum L. (common ice plant). These current oscillations showed a clear voltage dependence and appeared at membrane potentials more positive than 90-100 mV. This paper describes the oscillations in terms of two separate mechanisms. First, the Mesembryanthemum vacuolar membrane shows a negative slope conductance at membrane potentials more positive than 100-120 mV. The fact that the oscillations and the negative slope conductance show a similar threshold potential suggests that (part of) the same mechanism is involved in both phenomena. The second mechanism involved is the voltage drop across the series resistance. As a result, the potential actually experienced by the vacuolar membrane deviates from the command potential defined by the patch-clamp amplifier. This deviation depends in an Ohmic manner on the current magnitude. We suggest that the interplay of the negative slope conductance and the voltage drop across the series resistance can cause a positive feedback which is responsible for the current oscillations.

Electric Conductivity↗

A patch-clamp study of ion channels in protoplasts prepared from the marine alga Valonia utricularis.

The giant marine alga Valonia utricularis is a classical model system for studying the electrophysiology and water relations of plant cells by using microelectrode and pressure probe techniques. The recent finding that protoplasts can be prepared from the giant "mother cells" (Wang, J., Sukhorukov, V.L., Djuzenova, C.S., Zimmermann, U., Müller, T., Fuhr, G., 1997, Protoplasma 196:123-134) allowed the use of the patch-clamp technique to examine ion channel activity in the plasmalemma of this species. Outside-out and cell-attached experiments displayed three different types of voltage-gated Cl(-) channels (VAC1, VAC2, VAC3, Valonia Anion Channel 1,2,3), one voltage-gated K(+) channel (VKC1, Valonia K(+) Channel 1) as well as stretch-activated channels. In symmetrical 150 mm Cl(-) media, VAC1 was most frequently observed and had a single channel conductance of 36 +/- 7 pS (n = 4) in the outside-out and 33 +/- 5 pS (n = 10) in the cell-attached configuration. The reversal potential of the corresponding current-voltage curves was within 0 +/- 4 mV (n = 4, outside-out) and 9 +/- 7 mV (n = 10, cell-attached) close to the Nernst potential of Cl(-) and shifted towards more negative values when cell-attached experiments were performed in asymmetrical 50:150 mm Cl(-) media (bath/pipette; E(Cl(-)) -20 +/- 7 mV (n = 4); Nernst potential -28 mV). Consistent with a selectivity for Cl(-), VAC1 was inhibited by 100 micronM DIDS (4, 4'-diisothiocyanatostilbene-2,2'-disulfonic acid). VAC1 was activated by a hyperpolarization of the patch. Boltzmann fits of the channel activity under symmetrical 150 mm Cl(-) conditions yielded a midpoint potential of -12 +/- 5 mV (n = 4, outside-out) and -3 +/- 6 mV (n = 9, cell-attached) and corresponding apparent minimum gating charges of 15 +/- 3 (n = 4) and 18 +/- 5 (n = 9). The midpoint potential shifted to more negative values in the presence of a Cl(-) gradient. VAC2 was activated by voltages more negative than E(Cl(-)) and was always observed together with VAC1, but less frequently. It showed a "flickering" gating. The single channel conductance was 99 +/- 10 pS (n = 6). VAC3 was activated by membrane depolarization and frequently exhibited several subconductance states. The single channel conductance of the main conductance state was 36 +/- 5 pS (n = 5). VKC1 was also activated by positive clamped voltages. Up to three conductance states occurred whereby the main conductance state had a single channel conductance of 124 +/- 27 pS (n = 6). In the light of the above results it seems to be likely that VAC1 contributes mainly to the Cl(-) conductance of the plasmalemma of the turgescent "mother cells" and that this channel (as well as VAC2) can operate in the physiological membrane potential range. The physiological significance of VAC3 and VKC1 is unknown, but may be related (as the stretch-activated channels) to processes involved in turgor regulation.

4,4'-Diisothiocyanostilbene-2,2'-Disulfonic Acid↗

Voltage-gated calcium and Ca2+-activated chloride channels and Ca2+ transients: voltage-clamp studies of perfused and intact cells of Chara.

The voltage-clamp technique was used to study Ca(2+) and Cl(-) transient currents in the plasmalemma of tonoplast-free and intact Chara corallina cells. In tonoplast-free cells [perfused medium with ethylene glycol bis(2-aminoethyl ether)tetraacetic acid] long-term inward and outward currents through Ca channels consisted of two components: with and without time-dependent inactivation. The voltage dependence of the Ca channel activation ratio was found to be sigmoid-shaped, with about -140-mV activation threshold, reaching a plateau at V>50 mV. As the voltage increased, the characteristic activation time decreased from approximately 10(3) ms in the threshold region to approximately 10 ms in the positive region. The positive pulse-activated channels can then be completely deactivated, which is recorded by the Ca(2+) tail currents, at below-threshold negative voltages with millisecond-range time constants. This tail current is used for fast and brief Ca(2+) injection into tonoplast-free and intact cells, to activate the chloride channels by Ca(2+) . When cells are perfused with EDTA-containing medium in the presence of excess Mg(2+), this method of injection allows the free submembrane Ca(2+) concentration, [Ca(2+)](c), to be raised rapidly to several tens of micromoles per liter. Then a chloride component is recorded in the inward tail current, with the amplitude proportional to [see text]. When Ca(2+) is thus injected into an intact cell, it induces an inward current in the voltage-clamped plasmalemma, having activation-inactivation kinetics qualitatively resembling that in EDTA-perfused cells, but a considerably higher amplitude and duration (approximately 10 A m(-2) and tau(inact)~0.5 s at -200 mV). Analysis of our data and theoretical considerations indicate that the [Ca(2+)](c) rise during cell excitation is caused mainly by Ca(2+) entry through plasmalemma Ca channels rather than by Ca(2+) release from intracellular stores.

Calcium↗

Grey-box pharmacokinetic/pharmacodynamic modelling of a euglycaemic clamp study.

Grey-box pharmacokinetic/pharmacodynamic (PK/PD) modelling is presented as a promising way of modelling the pharmacokinetics and pharmacodynamics of the in vivo system of insulin and glucose and to estimate model and derived PK/PD parameters. The concept behind grey-box modelling consists in using a priori physiological knowledge along with information from data in the estimation of model parameters. The PK/PD properties of two types of insulin are investigated in a euglycaemic clamp study where a single bolus of insulin is injected subcutaneously. The effect of insulin on the glucose disappearance is investigated by artificially maintaining a blood glucose concentration close to the normal fasting level. The infused glucose needed to maintain the clamped blood glucose concentration can therefore be used as a measure for the glucose utilization. The PK and PD parameters are successfully estimated simultaneously thereby describing the uptake, distribution, and effect of the two different types of insulin.

Adolescent↗

Cytochemical and patch-clamp studies of calcium influx through voltage-dependent Ca2+ channels in vestibular supporting cells of guinea pigs.

To clarify whether or not vestibular supporting cells have voltage-dependent Ca2+ channels, cytochemical and patch-clamp studies were performed using cells isolated from the ampullae of the semicircular canal of the guinea pig. Image analysis used fura-2 as a Ca(2+)-sensitive fluorescence dye and showed that the intracellular Ca2+ concentration ([Ca2+]i) increased with bath application of high (150 mM)K+, but was unaffected by 80 mM K+. The increase in [Ca2+]i induced by high K+ was completely blocked by 1 microM nifedipine as an L-type Ca2+ channel antagonist. In the patch-clamp whole-cell recording of the isolated supporting cells, the voltage-dependent inward current was induced by a depolarizing pulse lasting 2 s in a high (50 mM) Ca2+ and tetraethylammonium-containing external solution replaced by choline chloride and a Cs(+)-containing internal solution. The inward current was obtained when the membrane was depolarized to -50 mV and maximum current was observed at -10 to +10 mV. This inward current was completely blocked by 1 microM nifedipine. These findings strongly suggest that voltage-dependent Ca2+ channels exist in the vestibular supporting cells and regulate Ca2+ concentration in the vestibular endolymph.

Animals↗

Corrections for space-clamp errors in measured parameters of voltage-dependent conductances in a cylindrical neurite.

The ability to correct parameters of voltage-gated conductances measured under poor spatial control by point voltage clamp could rescue much flawed experimental data. We explore a strategy for correcting errors in experiments that employs a full-trace approach to parameter determination. Simulated soma voltage-clamp runs are made on a model neuron with a single voltage-gated, Hodgkin-Huxley channel type distributed uniformly along an elongate process. Estimates for both kinetic and I(V) parameters are obtained by fitting a form of the Hodgkin-Huxley equations to the complete time course of leak-subtracted current curves. The fitted parameters are used to determine how much correction in each parameter is needed to regenerate the set actually belonging to the channel. Corrections are generated for a range of neurite lengths, conductance densities, and channel characteristics.

Action Potentials↗

Patch-clamp recording in brain slices with improved slicer technology.

The use of advanced patch-clamp recording techniques in brain slices, such as simultaneous recording from multiple neurons and recording from dendrites or presynaptic terminals, demands slices of the highest quality. In this context the mechanics of the tissue slicer are an important factor. Ideally, a tissue slicer should generate large-amplitude and high-frequency movements of the cutting blade in a horizontal axis, with minimal vibrations in the vertical axis. We developed a vibroslicer that fulfils these in part conflicting requirements. The oscillator is a permanent-magnet-coil-leaf-spring system. Using an auto-resonant mechano-electrical feedback circuit, large horizontal oscillations (up to 3 mm peak-to-peak) with high frequency ( approximately 90 Hz) are generated. To minimize vertical vibrations, an adjustment mechanism was employed that allowed alignment of the cutting edge of the blade with the major axis of the oscillation. A vibroprobe device was used to monitor vertical vibrations during adjustment. The system is based on the shading of the light path between a light-emitting diode (LED) and a photodiode. Vibroprobe monitoring revealed that the vibroslicer, after appropriate adjustment, generated vertical vibrations of <1 microm, significantly less than many commercial tissue slicers. Light- and electron-microscopic analysis of surface layers of slices cut with the vibroslicer showed that cellular elements, dendritic processes and presynaptic terminals are well preserved under these conditions, as required for patch-clamp recording from these structures.

Animals↗

High-speed pressure clamp.

We built a high-speed, pneumatic pressure clamp to stimulate patch-clamped membranes mechanically. The key control element is a newly designed differential valve that uses a single, nickel-plated piezoelectric bending element to control both pressure and vacuum. To minimize response time, the valve body was designed with minimum dead volume. The result is improved response time and stability with a threefold decrease in actuation latency. Tight valve clearances minimize the steady-state air flow, permitting us to use small resonant-piston pumps to supply pressure and vacuum. To protect the valve from water contamination in the event of a broken pipette, an optical sensor detects water entering the valve and increases pressure rapidly to clear the system. The open-loop time constant for pressure is 2.5 ms for a 100-mmHg step, and the closed-loop settling time is 500-600 micros. Valve actuation latency is 120 micros. The system performance is illustrated for mechanically induced changes in patch capacitance.

Animals↗