Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CENTRIFUGATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

Membrane hybridization by centrifugation analysed by lipid phase transitions and reconstitution of NADH-oxidase-activity.

A procedure is described to hybridize cytoplasmic membranes of Escherichia coli. The method involves high-speed contrifugation of two different vesicle preparations at 37 degrees C in the presence of cations such as spermine or Mg2+. The occurrence of hybridization is shown by the following experiments. Firstly, formation of a mixed lipis phase starting from two membranes having a different hydrocarbon chain composition in their phospholipids. Secondly, formation of a hybrid membrane having an intermediate lipid to protein ratio from two membrane fractions having different lipid to protein ratios. Thirdly, reconstitution of NADH oxidase activity by hybridization of two membrane fractions, one lacking active cytochromes and the other being deficient in quinones. It is proposed that hybridization occurs by fusion of vesicles during the tight association of collapsed vesicles under high centrifugal forces. This interpretation is supported by electron microscopy of the membrane pellets after centrifugation. However, lipid transfer as the mechanism of hybridization cannot be excluded and attempts to reconstitute active galactoside transport by complementation of beta-galactoside transport-deficient membranes and cytochrome-deficient membranes have been unsuccessful.

Calcium↗

Uptake and release of gamma-aminobutyric acid in the guinea pig cochlear nucleus after axotomy of cochlear and centrifugal fibers.

This study attempts to determine if gamma-aminobutyric acid (GABA) may be a transmitter of cochlear nerve fibers projecting from the cochlea to the cochlear nucleus, and of centrifugal fibers projecting to the cochlear nucleus via the trapezoid body and the acoustic striae of the medulla. The uptake and the electrically evoked release of exogenous [14C]GABA were measured, in vitro, in the three major subdivisions of the guinea pig cochlear nucleus; the anteroventral, posteroventral, and dorsal cochlear nuclei. These activities were compared using unlesioned animals, animals with bilateral cochlear ablations, and animals whose trapezoid body and acoustic striae were interrupted on the right side of the medulla. Subdivisions from unlesioned animals took up [14C]GABA, achieving concentrations in the tissues that were 11-19 times that in the medium. Electrical stimulation evoked a Ca2+-dependent release of [14C]GABA from each subdivision. Bilateral cochlear ablation, which presumably destroyed the cochlear nerve fibers, had no effect on [14C]GABA uptake and release. Section of the trapezoid body and the acoustic striae on the right side of the medulla typically severed all known connections of the right posteroventral and dorsal cochlear nuclei with the rest of the brain, but left intact many connections involved with the right anteroventral cochlear nucleus. This lesion partially depressed [14C]GABA uptake and release in the right posteroventral and dorsal cochlear nuclei, but not in the right anteroventral cochlear nucleus. These findings suggest that one or more of the centrifugal tracts projecting to the cochlear nucleus may be GABAergic, 88% or more of the cochlear nerve fibers probably are not GABAergic, and some neurons of the cochlear nucleus are probably GABAergic.

Animals↗

In-vitro assessment of centrifugal pumps for ventricular assist.

Currently two major types of centrifugal pumps are commercially available for ventricular assist: the Biomedicus-cone (Group I) and the Centrimed-impeller pump (now Sarns 3M) (Group II). To compare them for blood trauma and hemolysis, an in-vitro experiment was designed with a Stöckert roller pump as a standard control (Group III). The in-vitro circuit was constructed consisting of a pump head, electromagnetic flow probe, polyvinyl chloride tubing and a reservoir, identical for all groups. Human ACD blood was used for priming and was circulated with a flow rate of 2 L/min for 24 h. Blood samples were taken at 0, 1, 3, 6, 12, and 24 h and zero control values were subtracted from the resulting data per time interval. Among the 16 parameters studied, a highly significant difference in favor of Group I was found for glutamate oxalacetate transaminase (GOT) and lactate dehydrogenase (p less than 0.0001) and for the free plasma hemoglobin (p less than 0.0001) after 12 and 24 h, respectively. The hemolytic index (Allen) again was lowest for group I in contrast to Groups II and III (0.012 versus 0.060 and 1.70) after 24 h. All other parameters studied did not render significant differences between the systems tested. The authors conclude that the Biomedicus pump currently is the least traumatic centrifugal pump for ventricular assist.

Blood↗

Centrifugal blood pump with a magnetically suspended impeller.

A centrifugal blood pump with a magnetically suspended impeller has been developed. It has a single inlet and outlet, and it generates centrifugal forces by the rotating impeller. The fluid-dynamical design for inflow and outflow through the impeller leads to elimination of the axial force and unbalanced radial force acting on the impeller. Consequently, three-component control systems, instead of five-component ones, are enough to position the impeller. The magnetically suspended impeller rotates by the magnetic coupling with the permanent magnets embedded in the outer rotator of the motor. This pump has enough performance to function as a blood pump. Further research on the null-power magnetic suspension and the generation of an efficient rotating magnetic field is in progress.

Equipment Design↗

A compact centrifugal pump for cardiopulmonary bypass.

A majority of the cardiopulmonary bypass (CPB) systems still utilize bulky roller pumps. A direct-drive small centrifugal pump intended for second-generation CPB pump has been developed. The pump has a 50 mm diameter impeller and provides a 6 L/min flow at 3,000 rpm against 300 mm Hg. A flexible drive shaft allows us to separate the pump head from the console resulting in easier manipulation. An in vitro study showed that the pump generated less hemolysis (index of hemolysis = 0.0011, comparable to the value for Bio-medicus BP-80). To improve blood flow around the shaft-seal region and to reduce thrombus formation around the shaft, six holes were drilled through the impeller. In biventricular bypass experiments using calves, our pump demonstrated excellent antithrombogenicity and durability for 48 h. And the compact and atraumatic centrifugal pump system showed excellent performance and easy manipulation under actual CPB conditions in animal.

Animals↗

A flow visualization study of centrifugal blood pumps developed for long-term usage.

We have developed centrifugal pumps for long-term circulatory assistance, with the final goal of a completely implantable ventricular assist device or total artificial heart. The previous model, NCVC-0, was characterized by a nonseal design and few flow-stagnating parts and acquired high durability and antithrombogenicity. To improve its pumping performance, NCVC-0 was modified. In the new model, NCVC-1, the profile shape of the impeller was changed from flat to conical, the number of vanes from 4 to 6, and the vane entrance angle from 30 degrees to 60 degrees. A flow visualization study performed by means of a combination of the polystyrene tracer method and the light-cutting method indicated decreased flow turbulence between vanes in NCVC-1, which corresponded well with the increased pumping performance. Flow visualization is a useful method to evaluate the design elements that are closely related to the pumping performance of a centrifugal blood pump.

Equipment Design↗

Development of the Baylor-Nikkiso centrifugal pump with a purging system for circulatory support.

The Baylor-Nikkiso centrifugal pump is a magnetically coupled system with a V-ring seal separating the pump and the actuator chamber. To prevent thrombus formation behind the impeller and to extend the life of the pump to 2 weeks of continuous operation, we incorporated a purging chamber behind the V-ring seal. An external pump connected to this purging chamber infused fluid at a constant rate to wash the shaft-seal area. To evaluate the effectiveness of the purging system, we have carried out biventricular bypass experiments using calves. The purging system was successful in reducing the level of thrombus formation after 2 weeks of operation. The results of these studies confirmed that the Baylor-Nikkiso centrifugal pump with this purging system is suitable for at least 2 weeks of continuous operation as a circulatory support system.

Animals↗

Frequency of seal disruption with the sarns centrifugal pump in postcardiotomy circulatory assist.

We have used the Sarns centrifugal pump for uni- or biventricular assist in 58 patients with postcardiotomy cardiogenic shock. This device utilizes a spinning impeller pump that is magnetically coupled to a motor imparting rotary motion to incoming perfusate. Nine patients (16%) experienced 22 device failures, which consisted of a nonvisible disruption of the seal within the pumphead. This allowed fluid to accumulate between the pumphead and the motor necessitating change of the pumphead. The time to seal disruption was 10-149 h (median 48). Of the 22 seal disruptions, 18 occurred in 73 left ventricular pumps (25%), and 4 occurred in 38 right ventricular pumps (11%) p = 0.015. Left ventricular pumps failed at 10-144 h (median 48), and right ventricular pumps failed at 48-149 h (median 83) p = 0.02. The Sarns centrifugal pump is dependable for its intended use of cardiopulmonary perfusion. However, when used for postcardiotomy assist, seal disruption should be expected. It occurs sooner and is more common during left ventricular assist. We recommend inspection of the magnet chamber for evidence of seal disruption every 12 h with left ventricular assist and every 24 h with right ventricular assist.

Adolescent↗

The next generation Baylor C-Gyro Pump: antithrombogenic "free impeller" design for long-term centrifugal VAD.

The new generation centrifugal blood pump, the C2 Gyro Pump "Free Impeller Model" specifically designed for long-term ventricular assistance and a bridge to transplantation, has been developed. In the free impeller design, the impeller was completely freed from mechanical tethers by eliminating the shaft. This unique design allowed the incorporation of a center-penetrating hole in the impeller, called the center conduit, which accelerates the secondary blood flow from the bottom to the top of the impeller. During in vitro performance tests, two characteristic impeller motions, called floating mode and wandering rotational axis, were observed. In the floating mode, the impeller seemed to be floating without touching the pump casing and resulted in the idea of no bearing contact. Also, the rotational axis of the impeller exhibited a small circular motion and illustrated the idea of no stationary area in the blood path. These three characteristics are expected to be advantageous for anti-thrombogenicity and low hemolysis which are essential for a long-term centrifugal VAD.

Equipment Design↗

A miniaturized centrifugal pump for assist circulation.

The newly developed Nikkiso HMS-15 is a miniaturized centrifugal pump. It has an impeller diameter of only 50 mm and a priming volume of only 25 ml. A totally new approach was applied to develop this very small pump. The new pump showed comparable hemolysis with pumps twice as big (e.g., the most widely used cone-shaped centrifugal pump [index of hemolysis, 0.005]). This finding refutes the belief that the pump diameter must be sufficiently large in size. Clinical application for cardiac assist was performed for 48 h without any thrombus formation despite low heparin dosage. Also, the pump showed quite favorable blood trauma when applied as a pump for cardiopulmonary bypass during open heart surgery. The compactness, the high controllability, and the system versatility proved to be very effective for clinical application. This pump is considered very reliable for its highly optimized design.

Aged↗

Less platelet damage in the curved vane centrifugal pump: a comparative study with the roller pump in open heart surgery.

The centrifugal pump with the curved vane (Lifestream Centrifugal Pump [LCP]) was applied to cardiopulmonary bypass (CPB) in 10 patients who underwent elective coronary artery bypass grafting. Serum hemoglobin levels, platelet counts, and serum beta-thromboglogulin (beta-TG) levels were measured during CPB. The results were compared with those for a comparative roller pump (RP) group (n = 10). There was no difference in CPB time between LCP (112 +/- 22 min) and RP (121 +/- 22 min) groups. Serum beta-TG levels (ng/ml) were lower in the LCP group than in the RP group (34 +/- 9 vs. 101 +/- 80, 5 min; 81 +/- 33 vs. 236 +/- 112, 30 min; 120 +/- 53 vs. 314 +/- 100, 60 min after initiation of CPB; p < 0.05). There were no significant differences in hemolysis and platelet depletion. The LCP showed excellent hemodynamic performance with less blood trauma in clinical application to open heart surgery.

Cardiopulmonary Bypass↗

Clinical experience with Nikkiso centrifugal pumps for extracorporeal circulation.

A comparative study of a newly developed impeller-type centrifugal pump, Nikkiso HMS-15, was made to assess the effects on hemolysis, platelet function, and renal function for extracorporeal circulation (ECC) during open heart surgery. The Bio-pump (cone-type, Medtronic) and the roller pump were used as controls. The increase of serum hemoglobin level in the Nikkiso pump was significantly lower than that in the other pumps. The decrease of platelet counts was recognized after the initiation of ECC in the three pumps whereas the levels of platelet factor 4 and beta-thromboglobulin in the Nikkiso pump group increased by far less than in the other two groups. Moreover, renal function was better maintained in the Nikkiso pump group; in particular, a significantly higher urine output was recorded during ECC and for 1 h after the termination of ECC. The results of our clinical studies suggest that the Nikkiso centrifugal pump is suitable for ECC during open heart surgery.

Extracorporeal Circulation↗

Computational prediction of hemolysis in a centrifugal ventricular assist device.

This paper describes the use of computational fluid dynamics (CFD) to predict numerically the hemolysis in centrifugal pumps. A numerical hydrodynamical model, based on the full Navier-Stokes equation, was used to obtain the flow in a vaneless centrifugal pump (of corotating disks type). After proper postprocessing, critical zones in the channel were identified by means of two-dimensional color-coded maps of %Hb release. Simulation of different conditions revealed that flow behavior at the entrance region of the channel is the main cause of blood trauma in such devices. A useful feature resulting from the CFD simulation is the visualization of critical flow zones that are impossible to determine experimentally with in vitro hemolysis tests.

Heart-Assist Devices↗

Flow visualization study on centrifugal blood pump using a high speed video camera.

Flow visualization is widely applied to evaluate rotary blood pumps; however, it is very difficult to visualize flow near the vanes of centrifugal blood pumps because the rotational speed of the impeller is usually several thousand rpm. In this study, a tracer method with a high speed video camera that can take more than 2,000 frames/s was utilized for flow visualization together with computer-assisted image measurement. This method visualized the complex secondary flow pattern near the vanes of the impeller, such as the vortex and recirculation. It also visualized the enhanced washout effect by the secondary washout vanes on the backside of the impeller. The proposed method was effective to analyze the flow pattern in the centrifugal blood pump by providing useful information for better design of the pump hemolysis and thrombus formation.

Blood Flow Velocity↗

A preliminary flow visualization study in a multiple disk centrifugal artificial ventricle.

Flow patterns in a multiple disk centrifugal pump were analyzed so that the device could be incorporated as a ventricular assist or a bridge-to-transplant device. The pump operates either in pulsatile or steady flow modes with the ability to change modes within a fraction of a second. The pump was tested on a mock circulatory system consisting of an arterial fluid capacitor, a systemic resistor, and a venous capacitor. Arterial volume flow rate, arterial pressure, inlet (venous) pressure, and pump rotation speed are continually monitored. A glycerin/water solution is used as a blood analog. Flow visualization was performed with a 3 mW yellow laser, sheet lens, neutrally buoyant amberlite particles, and both still and motion picture photography. Flow patterns matched theoretical predictions very well; inlet flow spread radially outward through the disk annular spaces while propelled by shear and centrifugal forces.

Blood Cells↗

Eccentric inlet port of the pivot bearing supported Gyro centrifugal pump.

An eccentric inlet port is a unique feature of the pivot bearing supported Gyro Compact-1 Eccentric Inlet Port Model 3 (C1E3) centrifugal pump, a completely sealless centrifugal pump. The latest C1E3 has an eccentric inlet port with a 30 degree vertical angle. To investigate the adequacy of this 30 degree angle, flow visualization studies and in vitro hemolysis tests were performed, comparing 4 pumps, each with a different angle of the eccentric inlet port (0, 30, 60, and 90 degrees). The flow visualization study utilizing a tracer method focused on the flow pattern just distal to the inlet port of each pump, and each pump was operated at 5 L/min against 100 mm Hg and 5 L/min against 350 mm Hg. In the pumps with angles of 90 and 60 degrees, the flow direction changed horizontally, causing a vortex formation. In the pump with the 30 degree angle, the inflow did not change its course, resulting in minimal space for vortex formation. In the pump with the 0 degree angle, the inflow collided with the pump housing, resulting in a small vortex formation along the housing surface. The in vitro hemolysis tests at 5 L/min against 350 mm Hg revealed that the pump with the 30 degree angle was the least hemolytic and the pump with the 90 degree angle was the most hemolytic among the 4 pumps. These results suggest that the angle of the eccentric inlet port of the Gyro C1E3 pump should be 30 degrees to have less vortex formation and less red blood cell trauma.

Animals↗

Centrifugal leukocytapheresis therapy for ulcerative colitis without concurrent corticosteroid administration.

Corticosteroid administration is an important therapy for active ulcerative colitis. However, long-term corticosteroid use is associated with serious complications such as osteoporosis, diabetes, and growth retardation. The effect of combination therapy corticosteroid plus leukocytapheresis has been previously reported, but that of leukocytapheresis with no corticosteroid is unknown. We carried out a preliminary study of six patients (two men and four women) with active ulcerative colitis (severe in two, moderately severe in four) who did not respond to 5-aminosalicylate derivatives, but refused corticosteroid use. Centrifugal leukocytapheresis was carried out once per week totaling four sessions per course. Treatment was considered effective when patients experienced clinical remission, which was defined as a frequency of diarrhea of four times or less and absence of visible blood in the stool, after one course. Leukocytapheresis was effective in five of six patients(83%). With cases stratified by severity, both severe cases and three of four moderately severe cases showed effectiveness. Clinical activity scores according to Lichtiger et al. in cases where leukocytapheresis was effective decreased from 9.8 to 6.6 at 1 week (P < 0.0001), declining further 2.4 at the end of the course. No obvious complications of leukocytapheresis were noted except for a decrease in hemoglobin by 1 g/dL. Centrifugal leukocytapheresis without corticosteroid treatment can induce remission in patients with active ulcerative colitis, and might be particularly beneficial for patients in whom adverse effects preclude the use of corticosteroids.

Adolescent↗

Centrifugal dorsal root discharges induced by motoneurone activation.

1. It has been confirmed that antidromic stimulation of motoneurones in the cat lumbar cord can induce, when properly conditioned, a centrifugal discharge in dorsal root afferent fibres.2. The effective conditioning can be (a) an orthodromic volley to the same or an adjacent dorsal root, (b) a volley to the dorsal column one or two segments above the tested level, or (c) a natural stimulus applied to the ipsi- or contralateral hind limb.3. The conditioning stimulus acts by increasing presynaptic excitability; the peak of its effect (maximum presynaptic depolarization) occurs 7-10 msec after the arrival of the conditioning volley to the cord and then quickly decays.4. A large antidromic field potential in the ventral horn is not necessary for the production of a centrifugal dorsal root discharge. Activation of a ventral root filament of approximately 100 mu in diameter can still induce such a discharge in a single dorsal root fibre. Furthermore, antidromic stimulation of the remaining fibres of the same ventral root cannot affect the terminals activated by the thin ventral root filament.5. The phenomenon of motoneurone-presynaptic interaction was obtained in different types of experimental preparations: acute and chronic spinal, anaemic and midcollicular decerebrate, animals with intact supraspinal centres, and one animal without acute laminectomy.

Action Potentials↗