Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AEROSOLS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73Linked to original sources

[Chronic obstructive respiration disorders imaged by inhalation scintigraphy. Differential diagnosis and early detection using radio-aerosols].

Inhalation radioaerosol lung imaging was performed in 86 patients with chronic obstructive lung disease (COLD) and in 45 asymptomatic smokers with small airways dysfunction. Within certain limits analysis of abnormal aerosol scans helped distinguish emphysematous from brochitic and asthmatic types of disease. Patients with asthma often responded to bronchodilator treatment and abnormal aerosol images reverted to near normal patterns. Besides a slight aerosol distribution inhomogeneity in the lung periphery, patients with small airways dysfunction showed significant hypodeposition of inhaled particles distal to the ciliated airways. Compared with small airways dysfunction, COLD was associated with an even more decreased aerosol penetrance to the alveoli.

Adult↗

[Comparative scintigraphic analysis of 99mTc aerosol inhalation and 81m Kr ventilation in chronic obstructive bronchial disease].

The usefulness of 99mTc-labelled serum albumin aerosol as a ventilation agent was compared to that of 81mKr gas in normal subjects and in patients with a wide range of pathological pulmonary function. In addition to visual analysis of the scintigrams, lung activity distribution was quantified by an index. In healthy subjects aerosol distribution was very similar to that of 81mKr gas. In patients with persistent obstruction of bronchial air flow, the aerosol tended to penetrate less well than 81mKr gas to the lung periphery and to show a more uneven pulmonary tracer distribution. Consequently the 81mKr gas technique resulted in underestimating bronchial obstructive defects compared with the radioaerosol method. The results indicate that unlike 81mKr gas imaging, small-particle aerosol scintigraphy provides a useful diagnostic technique for the detection of even mild air flow obstructions.

Adult↗

A controlled trial of trimethoprim-sulfamethoxazole or aerosolized pentamidine for secondary prophylaxis of Pneumocystis carinii pneumonia in patients with the acquired immunodeficiency syndrome. AIDS Clinical Trials Group Protocol 021.

BACKGROUND: Pneumocystis carinii pneumonia (PCP) continues to be the most common index diagnosis in the acquired immunodeficiency syndrome (AIDS), but it is not clear which of several available agents is the most effective in preventing a recurrence of PCP. METHODS: We conducted a comparative, open-label trial in 310 adults with AIDS who had recently recovered from an initial episode of PCP and had no treatment-limiting toxic effects of trimethoprim-sulfamethoxazole or pentamidine. All the patients were treated with zidovudine and were randomly assigned to receive either 800 mg of sulfamethoxazole and 160 mg of trimethoprim once daily or 300 mg of aerosolized pentamidine administered every four weeks by jet nebulizer. The participants were followed for a median of 17.4 months. RESULTS: In the trimethoprim-sulfamethoxazole group (n = 154) there were 14 recurrences of PCP, as compared with 36 recurrences (including 1 extrapulmonary recurrence) in the aerosolized-pentamidine group (n = 156). The estimated recurrence rates at 18 months were 11.4 percent with trimethoprim-sulfamethoxazole and 27.6 percent with pentamidine (P < 0.001). The risk of a recurrence (adjusted for initial CD4 cell count) was 3.25 times higher in the pentamidine group (P < 0.001, 95 percent confidence interval, 1.72 to 6.16). There were no significant differences between the groups in survival or in hematologic or hepatic toxicity. Crossovers from trimethoprim-sulfamethoxazole to aerosolized pentamidine were more common than the reverse (27 vs. 4 percent), partly because of the study protocols for the management of leukopenia. There were 19 serious bacterial infections in the trimethoprim-sulfamethoxazole group and 38 in the pentamidine group. The time to a first bacterial infection was significantly greater for those assigned to trimethoprim-sulfamethoxazole (P = 0.017). CONCLUSIONS: In patients with AIDS who are receiving zidovudine, trimethoprim-sulfamethoxazole is more effective than aerosolized pentamidine in conventional doses for the prevention of recurrent pneumocystis infection.

AIDS-Related Opportunistic Infections↗

Efficacy of aerosolized tobramycin in patients with cystic fibrosis.

BACKGROUND: Direct aerosol delivery of aminoglycosides such as tobramycin to the lower airways of patients with cystic fibrosis may control infection with Pseudomonas aeruginosa and improve pulmonary function, with low systemic toxicity. We conducted a randomized crossover study to evaluate the safety and efficacy of aerosolized tobramycin in patients with cystic fibrosis and P. aeruginosa infections. METHODS: Seventy-one patients with stable pulmonary status were recruited from seven U.S. centers for the treatment of cystic fibrosis and randomly assigned to one of two crossover regimens. Group 1 received 600 mg of aerosolized tobramycin for 28 days, followed by half-strength physiologic saline (placebo) for two 28-day period. Group 2 received placebo for 28 days, followed by tobramycin for two 28-day periods. Pulmonary function, the density of P. aeruginosa in sputum, ototoxicity, nephrotoxicity, and the emergence of tobramycin-resistant P. aeruginosa were monitored. RESULTS: In the first 28-day period, treatment with tobramycin was associated with an increase in the percentage of the value predicted for forced expiratory volume in one second (9.7 percentage points higher than the value for placebo; P < 0.001), forced vital capacity (6.2 percentage points higher than the value for placebo; P = 0.014), and forced expiratory flow at the midportion of the vital capacity (13.0 percentage points higher than the value for placebo; P < 0.001). A decrease in the density of P. aeruginosa in sputum by a factor of 100 (P < 0.001) was found during all periods of tobramycin administration. Neither ototoxicity nor nephrotoxicity was detected. The frequency of the emergence of tobramycin-resistant bacteria was similar during both tobramycin and placebo administration. CONCLUSIONS: The short-term aerosol administration of a high dose of tobramycin in patients with clinically stable cystic fibrosis is an efficacious and safe treatment for endobronchial infection with P. aeruginosa.

Adolescent↗

Long-term treatment of primary pulmonary hypertension with aerosolized iloprost, a prostacyclin analogue.

BACKGROUND: Continuous intravenous infusion of epoprostenol (prostacyclin) is an effective treatment for primary pulmonary hypertension. This approach requires the insertion of a permanent central venous catheter, with the associated risk of serious complications. Recently, aerosolized iloprost, a stable prostacyclin analogue, has been introduced as an alternative therapy for severe pulmonary hypertension. METHODS: We evaluated the effects of aerosolized iloprost on exercise capacity and hemodynamic variables over a one-year period in patients with primary pulmonary hypertension. RESULTS: Twenty-four patients with primary pulmonary hypertension received aerosolized iloprost at a daily dose of 100 or 150 microg for at least one year. The mean (+/-SD) distance covered in the six-minute walk test increased from 278+/-96 m at base line to 363+/-135 m after 12 months (P<0.001). During the same period, the mean pulmonary arterial pressure before the inhalation of iloprost declined from 59+/-10 mm Hg to 52+/-15 mm Hg (P=0.006), cardiac output increased from 3.8+/-1.4 liters per minute to 4.4+/-1.3 liters per minute (P=0.02), and pulmonary vascular resistance declined from 1205+/-467 dyn x sec x cm(-5) to 925+/-469 dyn x sec x cm(-5) (P<0.001). The treatment was generally well tolerated, except for mild coughing, minor headache, and jaw pain in some patients. CONCLUSIONS: Long-term treatment with aerosolized iloprost is safe and has sustained effects on exercise capacity and pulmonary hemodynamics in patients with primary pulmonary hypertension.

Administration, Inhalation↗

Release of allergens as respirable aerosols: A link between grass pollen and asthma.

BACKGROUND: Asthma incidence has long been linked to pollen, even though pollen grains are too large to penetrate into the airways where asthmatic responses originate. Pollen allergens found in small, respirable particles have been implicated in a number of asthma epidemics, particularly ones following rainfall or thunderstorms. OBJECTIVE: The aim of this study was to determine how pollen allergens form the respirable aerosols necessary for triggering asthma. METHODS: Flowering grasses were humidified and then dried in a controlled-environment chamber connected to a cascade impactor and an aerosol particle counter. Particles shed from the flowers were analyzed with high-resolution microscopy and immunolabeled with rabbit anti-Phl p 1 antibody, which is specific for group 1 pollen allergens. RESULTS: Contrary to what has been reported in other published accounts, most of the pollen in this investigation remained on the open anthers of wind pollinated plants unless disturbed-eg, by wind. Increasing humidity caused anthers to close. After a cycle of wetting and drying followed by wind disturbance, grasses flowering within a chamber produced an aerosol of particles that were collected in a cascade impactor. These particles consisted of fragmented pollen cytoplasm in the size range 0.12 to 4.67 microm; they were loaded with group 1 allergens. CONCLUSION: Here we provide the first direct observations of the release of grass pollen allergens as respirable aerosols. They can emanate directly from the flower after a moisture-drying cycle. This could explain asthmatic responses associated with grass pollination, particularly after moist weather conditions.

Aerosols↗

Opposing forces of aerosol cooling and El Nino drive coral bleaching on Caribbean reefs.

Bleaching of corals as a result of elevated sea surface temperatures (SST) is rapidly becoming a primary source of stress for reefs globally; the scale and extent of this threat will depend on how the drivers of SST interact to influence bleaching patterns. We demonstrate how the opposing forces of the El Niño-Southern Oscillation (ENSO) and levels of atmospheric aerosols drive regional-scale patterns of coral bleaching across the Caribbean. When aerosol levels are low, bleaching is largely determined by El Niño strength, but high aerosol levels mitigate the effects of a severe El Niño. High aerosol levels, resulting principally from recent volcanic activity, have thus protected Caribbean reefs from more frequent widespread bleaching events but cannot be relied on to provide similar protection in the future.

Aerosols↗

The relationships of aerosol deposition, lung size, and the rate of mucociliary clearance.

Although the effect of deposition pattern of an inhaled aerosol upon subsequent mucociliary clearance is well recognized, the influence of lung size on the rate of clearance has not been clearly defined. To examine the relationships of lung size in terms of the forced vital capacity (FVC) and aerosol deposition pattern to the rate of mucociliary clearance, we measured lung retention of an inhaled 8-micron aerosol for 120 min using a gamma camera in 13 healthy nonsmoking volunteers. The deposition pattern of the inhaled aerosol was defined in terms of the initial skew of the distribution of retained activity within the right lung (skew) and the percent retained at 24 hr (R24). Multiple regression analysis showed that FVC was responsible for approximately 36% of the variability in bronchial retention with time, with a lesser contribution from variations in deposition pattern (skew and R24). Mucociliary clearance was significantly slower (i.e., greater bronchial retention) in male subjects than in female subjects which can probably be attributed to the differences in FVC. Variations in lung sizes as well as deposition pattern should therefore be considered when making between subject comparisons of the mucociliary clearance rate.

Adult↗

Ventilatory responses in awake guinea pigs exposed to acid aerosols.

This study reports experiments designed to evaluate the dose and temporal effects of an atmospheric pollutant, sulfuric acid (H2SO4) aerosol, on the dynamic components of the respiratory cycle. Ventilation was measured in a whole-body barometric plethysmograph in unanesthetized, unrestrained animals following a 4-h exposure to H2SO4 aerosol at 14.1, 20.1, or 43.3 mg/m3. Lung injury was assessed by histopathology and bronchoalveolar lavage (BAL). Aerosol exposure with H2SO4 caused marked alterations in both the magnitude and composition of the ventilatory response, which were both dose and time dependent. At the highest concentration tested, there was a significant increase in tidal volume (deltaVt) and a decrease in breathing frequency (f) immediately after exposure. Analysis of BAL fluid at this time showed increased inflammatory cells and protein in the acid exposed animals, and histology showed hyaline membranes and acute inflammatory cells in the proximal acinar region. By 24 h postexposure, f significantly increased whereas deltaVt decreased. This pattern of breathing was interspersed with short periods of apnea. The onset of rapid, shallow breathing was associated with histological evidence of diffuse pulmonary edema. By contrast, the immediate postexposure period at the lowest concentration of H2SO4 aerosol was characterized by a significant increase in f and little or no effect on deltaVt. These effects diminished with time, and at 24 h postexposure ventilatory parameters were indistinguishable from baseline values. An apparent crossover between the effects associated with the high and low exposure concentrations was seen at the intermediate exposure concentration; however, closer inspection of these findings on an animal-by-animal basis revealed two populations of animals with respiratory characteristics of either the high-exposure or low-exposure groups. The data suggest that the guinea pig exhibits complex interactions between dose and time to response that are consistent with the activation of neural reflexes. The indirect plethysmographic method provides a simple means to assess these responses in a model system that avoids the use of anesthetics, surgery, and restraint.

Administration, Inhalation↗

Human tracheobronchial deposition and effect of a cholinergic aerosol inhaled by extremely slow inhalations.

Ten subjects inhaled the same amounts of cholinergic aerosol of a mass median diameter (MMD) of 7.7 microns in a normal provocation test and in a test with extremely slow inhalations (ESI). This new technique using ESI and large droplets/particles gives a high degree of deposition in small ciliated airways which cannot be obtained by using small particles. The purpose was to compare measured effects with calculated doses of the aerosol in large and small ciliated airways. The effect on large airways was measured by airway resistance (R(aw)), and the effect on small airways was measured by the phase III slope of single breath nitrogen test (N2-delta). Mouth and throat deposition was calculated from human experimental data, and deposition of the cholinergic aerosol into large and small airways was calculated, using a computerized lung model. The study showed that the extremely slow inhalation caused a larger effect on R(aw) and tendency to a larger effect on N2-delta compared to the effect in the normal provocation. Deposited dose in the large airways, in percent of inhaled dose, was calculated to be 25-33% for normal inhalation and 20-24% for ESI. Calculated deposited dose in the small airways (bronchioles; generations 12-16) was 1.8-3.4% for normal inhalation and 18-25% for ESI. For large airways a stronger effect was induced by ESI, perhaps by the more uniform distribution of particles within each generation, compared to normal inhalations when particles deposit near the bifurcations. Concerning the small airways, N2-delta did not differ significantly between normal and ESI provocations, indicating that they did not react much on cholinergic exposure. We believe that our approach using ESI for small airway deposition of a nebulized aerosol can be of value for estimating the effects of various substances on large and small airways.

Administration, Inhalation↗

Sulfuric acid aerosol induces changes in alveolar surface tension in the guinea pig but not in the rat.

The purpose of this study was to investigate the effects of an acid aerosol, at high concentration, on the surface properties of the extracellular fluid lining the airways and alveolae. Guinea pigs and rats were exposed to 43 mg/m3 and 94 mg/m3 of sulfuric acid aerosol mass median aerodynamic diameter (MMAD) 0.9 micron or water aerosol (control), respectively, for 4 hours in an exposure chamber. Surfactant material was extracted from bronchoalveolar lavage fluid (BAL) by centrifugation, and phospholipid, protein, and cell concentrations measured. The extract was reconstituted to 300 micrograms/mL of phospholipid, and its surface properties assessed with a captive bubble surfactometer. The minimum surface tension for the acid-exposed guinea pig BAL was 12.1 +/- 8.48 (mean +/- SD) mN/m, which was significantly higher than the control group, 2.0 +/- 0.43 (mean +/- SD) or the acid-exposed rats, 1.29 +/- 0.11 (mean +/- SD). The change in film area obtained by compressing the film from equilibrium surface tension (25 mN/m) to its minimum value (gamma min) was 62.9 +/- 13.83 (mean +/- SD)% for acid-exposed guinea pigs, compared to 16.3 +/- 5.77 (mean +/- SD)% for the control guinea pigs. The most sensitive index of surfactant inhibition was found to be the maximum film compressibility (Cmax) of the compression isotherm. This index was 119 times greater for the acid-exposed guinea pigs compared to control animals. These abnormalities were associated with an elevation of total protein (0.95 +/- 0.33 [mean +/- SD] mg/mL compared to 0.13 +/- 0.03 [mean +/- SD] mg/mL in controls) and polymorphonuclear leucocytes in the BAL. There was no change in total phospholipids. By contrast BAL retrieved from rats exposed to approximately twice the concentration of acid aerosol showed no cellular nor biochemical abnormalities and its surface tension properties were normal. We conclude that the abnormalities of surfactant activity in the acid-exposed guinea pigs result from the cellular and humoral responses of acute lung injury rather than a direct effect of acid.

Administration, Inhalation↗

Speciation of arsenic in ambient aerosols collected in Los Angeles.

First-time measurements of the potentially toxic inorganic species of arsenic (arsenite and arsenate) have been obtained in fine (less than 2.5 microns AD) and coarse (greater than 2.5 microns AD) atmospheric particles in the Los Angeles area. A recently developed method that includes procedures for sample collection, preparation, and analysis was used in this study. Size-fractionated aerosol samples were collected with a high-volume dichotomous virtual impactor that employed polytetrafluoroethylene filters. Results were obtained for the recovery of arsenic standards added to unexposed and collected filters. Data from this study, indicated that the recently developed speciation method can be used to determine concentrations of As(III) and As(V) in atmospheric particulate matter samples. Size-fractionated aerosol samples were collected in the city of Industry during January and February 1987. In most samples, As(III) and As(V) were above the detection limit (approximately 1 ng m-3 of either species) in both aerosol size fractions. A greater portion (about 75 percent) of the two species were observed in the fine particles. The As(III)/As(V) ratio for both particle sizes was close to 1 (i.e., an equal mixture of both species). Comparison of total suspended particulate arsenic measured by the speciation method to that measured by a routine California Air Resources Board-approved procedure showed good agreement (r = 0.94), indicating both methods were approximately equivalent for the collection and analysis of aerosol arsenic.

Aerosols↗

Characteristics of an aerosol photometer while automatically controlling chamber dilution-air flow rate.

Trials were conducted to determine those factors that affect the accuracy of a direct-reading aerosol photometer when automatically controlling airflow rate within an exposure chamber to regulate airborne dust concentrations. Photometer response was affected by a shift in the aerosol size distribution caused by changes in chamber flow rate. In addition to a dilution effect, flow rate also determined the relative amount of aerosol lost to sedimentation within the chamber. Additional calculations were added to a computer control algorithm to compensate for these effects when attempting to automatically regulate flow based on a proportional-integral-derivative (PID) feedback control algorithm. A comparison between PID-controlled trials and those performed with a constant generator output rate and dilution-air flow rate demonstrated that there was no significant decrease in photometer accuracy despite the many changes in flow rate produced when using PID control. Likewise, the PID-controlled trials produced chamber aerosol concentrations within 1% of a desired level.

Aerosols↗

9-nitrocamptothecin liposome aerosol: lack of subacute toxicity in dogs.

9-Nitrocamptothecin (9-NC) dilauroylphosphatidylcholine (DLPC) liposome aerosol was evaluated for potential toxicity in an 8-wk, subacute toxicity study in dogs. Fourteen adult dogs were divided into 2 groups with 10 animals in the 9-NC-DLPC treatment group and 4 animals in the DLPC-only vehicle control group. 9-NC-DLPC was administered to the animals using an Aerotech II nebulizer flowing at 10 L/min. Full-face exposures for 60 min were conducted for 5 consecutive days a week for 8 wk. The estimated deposited aerosol dose was 24.7 microg/kg/day. Animals in the vehicle control group received aerosolized DLPC only. Body weight, food consumption, urinalysis, in-life observations, hematology, plasma chemistry, and necropsy and histopathology were monitored before and during the treatment period and in a subset of animals for 2 wk following the end of treatment. Animals were observed for signs of pharmacologic and/or toxicologic effects three times on days of dosing and once daily on nondosing days. 9-NC-DLPC liposomes administered as a small-particle aerosol were determined to be nontoxic to dogs when given for 5 days/wk, for a duration of 8 wk. DLPC-only liposome also had no toxic effects.

Administration, Inhalation↗

Short-term inhalation toxicity of polyisocyanate aerosols in rats: comparative assessment of irritant-threshold concentrations by bronchoalveolar lavage.

The object of this study was to compare the relative potency of respirable aerosols of the aliphatic hexamethylene 1,6-diisocyanate homopolymer of the isocyanurate type (HDI-IC) and the aromatic polymeric methylenediphenyl-4,4'-diisocyanate (pMDI) to elicit early changes in bronchoalveolar lavage fluid (BALF). The validity of the concentration x time (C x t) concept was addressed in rats exposed to concentrations from 3.4 to 58.1 mg pMDI/m3 and exposure durations of 6 h to 23 min, respectively (C x t approximately 1200 mg/m3-min). One additional group of rats was exposed to 2.7 mg MDA/m3 for 1 x 6 h, a putative product of hydrolysis of pMDI. In rats repeatedly exposed to 12.9 mg pMDI/m3 (6 h/day, 5 days/wk for 14 days), cumulative exposure-related changes were examined. Results show that total protein and angiotensin-converting enzyme (ACE) in BALF were among the most sensitive endpoints to probe early effects caused by exposure to irritant polyisocyanate aerosols. In the repeated-exposure study, BALF protein was maximal after the first exposure day. Based on these most sensitive endpoints in BALF, a benchmark no-effect threshold concentration of 0.5 and 3 mg/m3 was estimated for the pMDI and HDI-IC aerosol, respectively. The slope of the concentration-effect curve was steeper following exposure to HDI-IC than to pMDI. These estimated acute no-observed-effect levels (NOELs) were almost identical to those observed in longer term inhalation studies using conventional endpoints. It is concluded that pulmonary irritation caused by polyisocyanate aerosols can readily be quantified in an acute rat bioassay by the analysis of total protein in BALF.

Aerosols↗

Dynamics of oropharyngeal aerosol transport and deposition with the realistic flow pattern.

Aerosol flow and deposition in the model of human oropharynx was studied theoretically and experimentally for two realistic inspiratory patterns. The three-dimensional (3D) airflow structure in the sample geometry was solved with the computational fluid dynamics (CFD) code (Fluent), used to calculate dynamic distribution of particle deposition (0.3-10 mum). Experiments were done for the same flow conditions using the silicone-rubber cast with the matching geometry. Nonsteady breathing flows were reproduced with the computer-controlled artificial lung apparatus. Results of computations show that particles smaller than 3 mum easily pass the oropharynx during inspiration, while particles with a size close to 10 mum are substantially deposited, preferentially in the region of the naso-pharyngeal bend. For particles in the submicrometer size range, the spatial and temporal deposition pattern is more complicated, and strongly depends on breathing dynamics. The experiments confirmed that the mass median diameter (MMD) of the aerosol that penetrates the oropharynx and flows to the tracheobronchial tree is reduced. Measured total mass efficiency of deposition of the tested aerosol was in the range of 35-60%, depending on the breathing pattern. These findings are consistent with the CFD results. The methods and the preliminary results enable a more realistic analysis of dynamic effects during the flow of inhaled particles through the complex geometry of the oropharynx. Such analysis is needed for estimation of toxic potential of aerosols, related to their local deposition in different parts of the respiratory tract.

Adult↗

Challenges in validating CFD-derived inhaled aerosol deposition predictions.

Computational fluid dynamic (CFD) techniques have provided unprecedented opportunity for investigating inhaled particle deposition in realistic human airway geometries. Several recent articles describing local aerosol deposition predictions based upon "validated" CFD models have highlighted the challenges in validating local aerosol deposition predictions. These challenges include: (1) defining what is meant by validation; (2) defining appropriate experimental data for validation; and (3) determining when the agreement is not fortuitous. The term validation has numerous meanings, depending on the field and context in which it is used. For example, in computer programming it means the code executes as intended, to the experimentalist it means predicted results agree with matched experimental measurements, and to the risk assessor it implies that predictions using new parameters can be trusted. Based on the current literature it is not clear that a consensus exists for what constitutes a validated CFD model. It is also not clear what types of experimental data are needed or how closely the CFD input values and experimental conditions should be matched (similar or identical airway geometries, entrance airflow, or aerosol profiles) to validate CFD derived predictions. Due to the complexity of CFD computer codes and the multiplicity of deposition mechanisms, it is possible that total aerosol deposition may be accurately predicted and the resulting local particle deposition patterns are incorrect, or vice versa. Specific examples and suggestions for several challenges to experimentalists and modelers are presented.

Aerosols↗

Effects of on-road highway aerosol exposures on autonomic responses in aged, spontaneously hypertensive rats.

Epidemiological studies associate ambient particulate pollution with adverse health outcomes in elderly individuals with cardiopulmonary diseases. We hypothesized that freshly generated ultrafine particles (UFP) contribute to these effects, as they are present in high number concentrations on highways and vehicle passengers are exposed directly to them. Aged spontaneously hypertensive rats (9-12 mo) with implanted radiotelemetry devices were exposed to highway aerosol or filtered, gas-denuded (clean) air using an on-road exposure system to examine effects on heart rate (HR) and heart-rate variability (HRV). On the day of exposure, rats were pretreated with low-dose inhaled or injected lipopolysaccharide (LPS) to simulate respiratory tract or systemic inflammation, respectively. Exposures (6 h) in compartmentalized whole-body chambers were performed in an air conditioned compartment of a mobile laboratory on I-90 between Rochester and Buffalo, NY. HRV parameters were calculated from telemetric blood pressure signals and analyzed for the baseline period and for the first 32 h postexposure. The aerosol size (count median diameter = 15-20 nm; geometric standard deviation = 1.4-4.3) and number concentration (1.95-5.62 x 105/cm3) indicated the predominance of UFP. Intraperitoneal LPS significantly affected all of the parameters in a time-dependent manner; response patterns after inhaled or injected LPS pretreatment were similar, but more prolonged and greater in LPS-injected rats. A significant effect of highway aerosol was found, irrespective of pretreatment, which resulted in decreased HR in comparison to clean air-exposed rats. This effect was more persistent ( approximately 14 h) in those rats that received ip LPS as compared to saline. The highway aerosol also significantly affected short-term alterations in autonomic control of HR, as evidenced by elevations in normalized high frequency power and decreased vagosympathetic balance. These findings show that environmental exposure concentrations of mixed traffic-related UFP/gas-phase emissions can affect the autonomic nervous system.

Administration, Inhalation↗