A six-year retrospective study of Molloplast-B-lined dentures. Part I: Patient response.

A 6-year retrospective investigation elicited patient response to wearing Molloplast-B-lined dentures with the following results: 1. For nearly all the patients wearing a Molloplast-B-lined denture, their ability to wear it comfortably outweighs its disadvantages. 2. Nearly all the patients (95.4%) would elect to have a new soft-lined denture should their present one need replacement. 3. Nearly all the patients (93%) thought that their soft-lined dentures were more comfortable than their previous conventional acrylic resin ones. 4. Molloplast-B-lined dentures offered comfort to a significant number of patients in this study who had had a history of chronic discomfort with the wearing of conventional acrylic resin dentures. 5. The presence of a retracted tongue habit is likely to decrease the patient's satisfaction with the dentures.

Consumer Behavior↗

Accuracy of 2 impression techniques for ITI implants.

PURPOSE: The aim of this study was to compare the accuracy of casts produced by 2 impression techniques and elastomeric impression materials commonly used for the fabrication of implant-supported fixed prostheses. MATERIALS AND METHODS: A master model with 4 synOcta ITI implants placed unilaterally in place of the mandibular right central incisor, canine, first premolar, and first molar was constructed. Implant-level impressions were made by direct and indirect techniques. In the direct technique, synOcta impression caps with integral guide screws were used to transfer the implants using a custom-made acrylic resin tray and a polyether impression material (the PE direct technique). In the indirect technique, synOcta plastic positioning cylinders with impression caps were used to transfer the implants with either a custom-made acrylic resin tray and polyether impression material (the PE indirect technique) or with a stock tray with a vinylpolysiloxane impression material (the VPS indirect technique). After impression making, all casts (n = 21) were poured in type IV dental stone. Linear changes in -x or -y direction and numeric and descriptive angular changes between the implants were quantified using a coordinate measuring machine. RESULTS: Seven of 12 distance measurements (6 for -x direction, 6 for -y direction) showed differences between groups (P < .05). Of these, 5 were associated with the PE direct versus PE indirect and PE indirect versus VPS indirect, and 3 were associated with PE direct versus VPS indirect. Two implants also showed angular changes but only for the PE indirect technique versus the VPS indirect technique (P < .05). CONCLUSION: The snap-on VPS indirect impression technique using a stock tray, which has the advantages of being clinically convenient and eliminating repositioning after removal of the impression, resulted in dimensional accuracy similar to that achieved with the PE direct technique.

Dental Implants↗

Fracture resistance of mandibular molars with occlusal class I amalgam preparations.

The finding that large occlusal Class I restorations weaken premolars is not confirmed for natural mandibular molars because no statistically significant difference was found in the mean loads needed to fracture mandibular molars that were unprepared, minimally prepared, or prepared with a large occlusal amalgam restorations. Similarly, there was no statistically significant change in the amount of force necessary to fracture natural mandibular molars prepared with sharp vs round internal line angles (a no. 56 vs a no. 330 bur). Duplication of the experiment in acrylic resin mandibular molars confirmed the results of a previous experiment by Re and Norling as well as the results relating to sharp vs round internal line angles found in this experiment on natural mandibular molars. Acrylic resin teeth of homogeneous shape and substance overcome some of the sampling problems inherent in obtaining suitable human teeth for testing purposes; however, further testing of this material is indicated.

Dental Amalgam↗

An in vitro comparison of four surface preparation techniques for veneering a compomer to stainless steel.

Compomers are a new class of materials reportedly having the anticariogenicity and the bonding ability to metals similar to glass ionomers while maintaining the high esthetic qualities of composite resins. The purpose of this study was to determine and evaluate the shear bond strength and fracture pattern of a compomer (Dyract) to stainless steel crowns (SSCs) using different mechanical and chemical retention procedures for possible future development of a chair-side technique of producing esthetic SSCs. Thirty-two Unitek SSCs, divided into four groups, were mounted in autopolymerizing acrylic resin so that the resulting specimen has the crown's flat lingual surface projecting above and parallel to the top surface of the acrylic resin block. Dyract was placed in transparent nylon cylinders (3 x 3 mm) and bonded to SSC's surfaces directly (group 1) or following sandblasting of the SSCs (group 2). In group 3, Dyract was bonded to stainless steel lingual cleats that were previously spot-welded to the SSCs. In group 4, Dyract was bonded to sandblasted SSC's surfaces using Scotchbond Multi-Purpose Plus dental adhesive. Specimens were placed in deionized water for 1 hr at 37 degrees C. Shear bond strength was measured using a universal testing machine. The mean (SD) shear bond strengths in MPa for groups 1-4 respectively were as follows: 2.998 (1.381), 9.518 (2.464), 13.909 (1.653), and 9.372 (3.723). One-way ANOVA and Tukey's multiple range tests revealed a statistically significant difference between the groups (P < 0.00001). While no significant difference was found between groups 2 and 4 in which Dyract-PSA prime/adhesive and Scotchbond Multi-Purpose Plus dental adhesive were used, group 3 had significantly higher shear bond strength than other groups. Stereoscopic and SEM examinations revealed adhesive and mixed bond failures. It is concluded that the bond strength of Dyract to SSCs could be enhanced significantly by applying simple mechanical means of retention that could be available in dental offices.

Adhesives↗

Influence of the substrate and load application method on the shear bond strength of two adhesive systems.

The difficulty with comparing data obtained from different research centers calls for the standardization of laboratory procedures. This in vitro study compared the shear bond strength (SBS) of two adhesive systems--a self-etching system, Etch&Prime 3.0 and a one-bottle total-etch system, Single Bond--using two methods of load application (orthodontic edge wire loop and knife-edge blade). The hypothesis of substrate influence on the results obtained for both tests was also investigated. Twenty-four recently extracted human teeth were embedded in PVC tubes using acrylic resin and divided into two groups (n=12). A proximal surface of each tooth was wet-ground flat to expose dentin. Etch&Prime 3.0 and Single Bond adhesive systems were applied according to the manufacturers' instructions, and cone-shaped restorations were then built using Z100 resin composite. After storage in distilled water at 37 degrees C for 24 hours, the specimens were submitted to SBS testing using an orthodontic edge wire loop. The same teeth were again embedded in PVC tubes using acrylic resin and the other proximal surface was wet-ground flat to expose dentin. The specimens were prepared as explained above, and after storage in distilled water under the same previous conditions, they were submitted to SBS testing using a knife-edge blade. Two-way ANOVA and Tukey's tests were performed to determine any statistically significant differences among testing conditions. Results indicated that SBS values obtained for Etch&Prime 3.0 were significantly lower than Single Bond for both methods of load application (p<0.001). Regarding the load application method, statistically significant higher values (p<0.01) were obtained for Etch&Prime 3.0 when the knife-edge blade was used, whereas, no significant difference was observed between the two methods for Single Bond. There was a significant correlation between the bond strength values obtained on the same tooth (p<0.05). SEM examination found that Etch&Prime 3.0 demonstrated narrower tags than Single Bond. Moreover, the peritubular dentin was not adequately decalcified when Etch&Prime 3.0 was used.

Analysis of Variance↗

The accuracy of implant verification casts compared with casts produced from a rigid transfer coping technique.

PURPOSE: Prosthodontic techniques for implant-supported prostheses continue to evolve in an effort to facilitate treatment and minimize costs. Because research has shown no impression transfer technique to be without error, some clinicians have attempted to control the fit of prosthetic frameworks by reorienting sections of patterns or frameworks intraorally, fabricating a verification cast, and completing the prosthesis to fit such a cast. One manufacturer has attempted to meet both impression-making and verification-cast objectives by providing metallic impression copings (MICS) with extensions that allow contact between the copings for rigid fixation with acrylic resin before impression making. The purpose of this study was to determine the accuracy of casts produced from the MICS transfer process compared with casts produced from sectioned frameworks, where both techniques used a low-polymerization-shrinkage acrylic resin polymer to rigidly join the sections. MATERIALS AND METHODS: Using stainless steel measurement spheres as a reference point on each implant analog, the distances between analogs on the experimental casts were compared with the distances measured on the master cast. Seven casts were produced for each group and measured with a machinist's microscope at a 4-micron level of precision. RESULTS: The results revealed that the MICS transfer exhibited a mean error of 41 microns, which was significantly less than the verification-cast group mean error of 57 microns (p < .01, Student's t test). CONCLUSIONS: Given these results, clinicians can consider the rigid transfer technique as provided in the MICS transfer to be more accurate than the verification technique as outlined in this study.

Analysis of Variance↗

Use of tannic acid and silver enhancer to improve staining for electron microscopy and immunogold labeling.

Staining by uranyl acetate and lead citrate (UA-LC) of immunolabeled sections of unfixed glomerular basement membrane (GBM) digests embedded in low-acid glycol methacrylate (LA-GMA) is poor. The following were investigated for their ability to enhance contrast when applied to sections before UA-LC: potassium permanganate, phosphotungstic acid, gold chloride, osmium tetroxide, glutaraldehyde-osmium tetroxide, colloidal gold-silver enhancer, tannic acid, and glutaraldehyde-tannic acid. Silver enhancer (2 min incubation, no sodium thiosulfate step) gave dense GBM staining but not with immunogold labeling. Silver enhancer is recommended as a simple alternative to routine silver stains but not for contrast enhancement with immunogold labeling. Tannic acid (1% for 1 min or 0.005% for 10 sec) and glutaraldehyde (2.5% for 5 min) followed by tannic acid enhanced contrast and, when applied after immunolabeling, did not appear to affect probe levels. Tannic acid also enhanced the staining of fixed tissue in LR Gold acrylic resin and LA-GMA, but not of glutaraldehyde-osmium-fixed tissue in epoxy resin, even after sodium metaperiodate treatment. Treatment of sections with tannic acid is recommended for contrast enhancement in immunogold studies when osmium and tannic acid post-fixation must be avoided and the tissue is embedded in methacrylate or acrylic resin.

Basement Membrane↗

Avoiding cross-contamination in prosthodontics.

Reduction of the potential for cross-contamination in prosthodontics may be accomplished in the following ways: 1. Use surface covers such as clear plastic wraps or bags over instruments like face-bow, articulators, and torch handles. 2. Disinfect surfaces with chemical agents such as 1% iodine surgical scrub in 70% isopropyl alcohol in a ratio of 1:2 to 1:20. 3. Use unit-doses of petroleum jelly, impression materials, waxes, indelible pencils, etc. 4. Use mechanical sterilization to sterilize prosthodontic instruments as "set ups" not commonly thought compatible with the mechanical sterilization process (wood-handled knives, spatulas, Boley gauges, bite forks, impression trays, metal rulers, and acrylic resin burs). 5. Use chemical disinfectants such as Cidex, 2% glutaraldehyde; iodophor solution, 1% stock iodine diluted to 0.5% to 0.05% in 70% isopropyl alcohol; and 5.25% sodium hypochlorite diluted to 0.5% to 0.05% with tap water to disinfect removable partial denture frameworks, acrylic resin impression trays, immediate dentures, and mold and shade guide teeth. 6. Use a mask and latex disposable examination gloves during all patient contact. Efficient application of these recommendations will reduce the potential for disease transmission during the delivery of health care.

Communicable Disease Control↗

Color stability of provisional crown and fixed partial denture resins.

STATEMENT OF PROBLEM: Provisional resins are used extensively during fixed prosthodontic treatment and exhibit varying degrees of color change/discoloration over time. Data are needed to help predict color stability of provisional resins. PURPOSE: The purpose of this in vitro study was to measure the color change of 12 provisional prosthodontic materials after immersion in artificial saliva and artificial saliva-coffee solutions for 1, 2, and 4 weeks. MATERIAL AND METHODS: Twelve provisional materials were studied. Methacrylates consisted of Alike, Jet, Temporary Bridge Resin, Unifast, and Zeta CC. Bis-acryl resins included Instatemp, Integrity, Luxatemp, Protemp Garant, Provipont, Provitec, and Temphase. Ten specimens (25.4 mm x 25.4 mm x 2.4 mm) of each material were fabricated. Five specimens were stored at 37 degrees C in artificial saliva and 5 were stored in a solution of artificial saliva (400 cc) and coffee (800 cc). Baseline color was measured using a colorimeter. Further color measurements were made after 1, 2, and 4 weeks of immersion. CIE L *a *b * values were recorded and color differences (DeltaE) between baseline and each storage interval were calculated using a 2-way ANOVA with Bonferroni adjustment for multiple comparisons in conjunction with an overall alpha=.05. RESULTS: Results indicated the presence of strong interaction between material and storage solution regardless of the aspect of color considered (P<.0001 for DeltaE, DeltaL *, Deltaa *, and Deltab *). Coffee solution relative to saliva solution had the most significant impact on color change for Luxatemp, Protemp, and Temphase materials at 4 weeks, but the greatest overall color change for both coffee and saliva solutions was found for Provipont (DeltaE=9.40 coffee; 8.51 saliva) and the least overall color change for both solutions was found for Zeta CC (DeltaE=0.31 coffee; 0.23 saliva). CONCLUSIONS: Under the conditions of this study, 12 provisional crown and fixed partial denture resins demonstrated varying tendency to discolor over a range of time periods when immersed in artificial saliva and artificial saliva-coffee solutions.

Acrylic Resins↗

Effect of water storage on tooth displacement in maxillary complete dentures.

The purpose of this study was to investigate the effect of water storage at 37 degrees C (1 week, 1 month and 3 months) on tooth displacement in maxillary complete dentures. Ten maxillary dentures were constructed with Clássico acrylic resin using the conventional method of packing in metallic flasks. Metallic reference pins were placed in the incisal border of the central incisors (I), labial cusp of the first premolars (PM), and mesiolabial cusp of the second molars (M). Twelve hours after final flask closure, the acrylic resin was cured in water at 74 degrees C for 9 h. The flasks were removed from the thermo-polymerizing unit after water-cooling and the dentures were deflasked, finished and stored in water at a temperature of 37 degrees C for 1 week, 1 month and 3 months. At deflasking and at the water storage intervals, the I-I (incisor to incisor), PM-PM (pre-molar to pre-molar), and M-M (molar to molar) transversal distances, and LI-LM (left incisor to left molar) and RI-RM (right incisor to right molar) anteroposterior distances were measured using an optical microscope with 0.0005 mm accuracy. Data were submitted to ANOVA and Tukey's test (5%). Comparing the evaluation periods for each individual transversal and anteroposterior reference point, no statistically significant differences were observed among deflasking and the water storage intervals for I-I, PM-PM, M-M and RI-RM distances (p>0.05). For LI-LM, however, deflasking values were statistically different from those of 1-week, 1-month and 3-month water storage intervals (p<0.05), which, in turn, did not differ statistically to each other (p>0.05). These results confirm the complexity of tooth displacement in complete dentures. From a clinical standpoint, the difference observed in LI-LM distance after water storage would not be detected by the patients during clinical use.

Dentures↗

[Puncture technology and selective renal biopsy].

An experimental study of puncture technology for the kidney: We investigated the strength characteristics of tissues which are penetrated by the puncture needle for the kidney using a tension test. The tensile strength of the fascia, the muscle, the renal capsule, the renal parenchyma and the renal pelvis were 13.9, 1.1, 29.5, 0.5 and 21.4 kg/cm2, respectively. As the strengths differ, the needles for each tissue clearly need to be changed. Needle tip shape and needle material for kidney puncture were investigated by compression test, acryl resin injection into the renal vasculature, stereo-microscopy and scanning electron microscopy. These investigations revealed that the most suitable needle tip was a sharp cone shape, and material with a smooth surface and some flexibility such as Derlin seemed to be the most appropriate for the puncture needle for the kidney. Using the acryl resin injection method, stereo-microscopy and scanning electron microscopy, we studied the relative safety of single stage puncture and the repeated dilatation method to establish percutaneous nephrostomy. Single stage puncture seems to cause less damage to the kidney than the repeated dilatation method. Selective renal biopsy: A new puncture system using real-time ultrasound was developed at our clinic in 1978. The puncture procedure is monitored in 2 dimensional real-time images by a mechanical sector scanner equipped with an attachment for needle guidance. The application of the system to percutaneous renal biopsy is called "selective renal biopsy" because the specimen can be obtained selectively from any portion of the kidney.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Case report: aesthetic management of a localised periodontal defect with a gingival veneer prosthesis.

Traditionally acrylic resin gingival veneer prostheses have been used to disguise aesthetic deficiencies of maxillary anterior teeth following successful periodontal therapy and have been retained by engaging horizontal undercuts distal to the canine teeth. They are, however, versatile prostheses with uses in fixed and removable prosthodontics and therapeutic treatment of gingival conditions. In the case presented a small acrylic resin gingival veneer prosthesis retained by a resilient lining material was used to manage a localised periodontal defect of the mandibular central incisor teeth.

Adult↗

Immediate functional loading of Brånemark system implants in edentulous mandibles: clinical report of the results of developmental and simplified protocols.

PURPOSE: This report evaluates the 5-year results of 9 of 10 patients in a clinical investigation of immediate functional loading of Brånemark System implants in edentulous mandibles, and of 24 patients treated with a simplified protocol for the same indication. The purpose of the paper is to suggest a simple, reliable, and documented method for immediate implant loading of complete-arch mandibular prostheses. MATERIALS AND METHODS: Ten healthy patients in need of full-arch mandibular implant reconstruction (development group) were treated between December 1993 and December 1994 with 130 Brånemark System standard Implants, placed in fresh extraction and healed sites. Four implants per patient were immediately loaded with acrylic resin fixed prostheses. The prostheses were replaced by metal-framework conversion prostheses approximately 6 weeks later, and definitive metal-reinforced prostheses incorporating all implants were placed after second-stage surgery. An additional 24 patients were treated with a simplified protocol using a total of 144 implants placed between March 1997 and October 2000. In these patients, the acrylic resin prostheses were not disturbed for 3 months, and fewer implants were used with an increasing ratio of implants loaded. Eventually, all Implants were loaded immediately for the last patients treated. RESULTS: The prosthesis survival rate was 100% for the total material. In the developmental group, the implant cumulative survival rate was 80% for the immediately loaded implants after 5 years, while the 2-stage implants reached 96%. Bone level measurements showed no differences between immediate and 2-stage protocols for this group. The implant cumulative survival rate was 97% for the simplified treatment group. DISCUSSION AND CONCLUSION: A predictable and simple concept for loading of immediate implant prostheses in edentulous mandibles was demonstrated. Results from the development of this technique suggest that it may be essential to maintain the initial implant splinting over a healing period of about 3 months and that implant placement between the mental foramina provides optimal support.

Aged↗

Esthetic removable partial dentures.

This article provides information regarding the many ways that removable partial dentures (RPDs) may be used to solve restorative problems in the esthetic zone without displaying metal components or conspicuous acrylic resin flanges. The esthetic zone is defined and described, as are methods for recording it. Six dental categories are presented that assist the dentist in choosing a variety of RPD design concepts that may be used to avoid metal display while still satisfying basic principles of RPDs. New materials that may be utilized for optimal esthetics are presented and techniques for contouring acrylic resin bases and tinting denture bases are described.

Cuspid↗

A comparison of impression techniques for the CeraOne abutment.

PURPOSE: This study measured the accuracy of two impression techniques recommended by Noblepharma to be used with their CeraOne single tooth implant restoration. The first technique was to lute the impression transfer coping to the impression tray with autopolymerizing acrylic resin. The second was to leave the transfer coping free-standing in the impression material. MATERIALS AND METHODS: Thirty-five samples were made of a polyvinyl impression of the CeraOne transfer coping free-standing in the set impression material. Thirty-five samples were made of a polyvinyl impression of the CeraOne transfer coping luted to the impression tray with autopolymerizing acrylic resin. A jig was fabricated and used to record the spatial relations of the impressions and the transfer copings in reference to the jig. A light microscope was used to measure the distance between fixed markings on pressure sensitive paper, representing impression variations. RESULTS: The mean discrepancy in the horizontal plane for nonluted impressions was 0.094 mm, and for luted impressions, it was 0.275 mm. The mean discrepancy in the vertical plane for nonluted impressions was 0.154 mm, and for luted impressions, it was 0.192 mm. The differences found between the group with the luted impression tray and the group with the nonluted impression tray were found to be statistically significant. CONCLUSIONS: The more accurate of the two techniques is to transfer the impression coping without luting it to the impression tray.

Analysis of Variance↗

External skeletal fixation using methylmethacrylate. Current technique, clinical results, and indications.

External skeletal fixation using self-curing acrylic resin was applied by inserting A-O cortical screws into the diaphyseal region and A-O cancellous screws into the epiphyseal and/or metaphyseal regions. The position of the screws was designed to secure three-dimensional fixation. Points of insertion are selected that avoid infected bone, open wounds, thick muscles, and skin that is relatively mobile during joint motion. After reduction the acrylic resin rather than conventional metal linking devices is used for fixation of the screws. Once the fixation is completed, it is adjustable and so rigid that exercises for joint function are possible. The apparatus is light in weight and sufficiently compact to fit under clothing. In the 204 patients treated by this method, open tibial fractures occurred in 123; nonunion or delayed union in 28; metaphyseal and epiphyseal fractures in 30; femoral fractures in ten children; and miscellaneous fractures and other conditions in 13. Nearly all of the operations were successful. Three patients had refractures after removal of the fixation device.

Adult↗

A study of fixed prosthodontics performed at a university clinic 18 years after insertion.

This study obtained information on the long-term efficiency of prosthetic rehabilitation with fixed partial dentures performed by undergraduate students. From a list of discharged patients treated from 1975 to 1976 by undergraduate students at a dental school, 101 were recalled for free clinical examinations after 6, 11, and 18 years. A total of 163 fixed partial dentures were inserted. The majority (85%) of the fixed partial dentures were acrylic resin veneer-gold restorations; 15% were metal ceramic restorations. During this study period, 14 individuals died, leaving 138 fixed partial dentures to be examined. Of these, 35 (25%) were removed after a mean of 11 years in function, which left 75% in place and functioning after 18 years. The main causes for removal included caries, periodontitis, root fracture, and endodontic complications. Fewer metal ceramic restorations than acrylic resin veneer-gold restorations were removed. The removal rate for abutments with cast posts and cores was higher than the removal rate of total abutments. There was no difference in removal frequency between fixed partial dentures with moderate cantilever extensions and those with end-supported extensions.

Adult↗

[Cranioplasty with polymethylmethacrylate. The clinico-statistical considerations].

BACKGROUND: The main purpose of the reconstruction of the cranium is the protection of the brain. Besides we have to consider important functional and aesthetic necessities in order to achieve satisfactory results. METHODS: Thirty-six clinical cases, operated from November 1991 to June 1996, in which the reconstruction of the cranial vault is carried out by a polymethylmethacrylate acrylic resin are analysed. The causes and locations of the most common bone defects and the main indications for reconstruction are examined. While the repair of the osseous gaps caused by neoplasms is immediate, in the traumatic occurrences, in order to reduce the probability of infectious complications, an average time of 11 months elapsed from the first operation. The surgical technique, with slightest alterations, is the same in all the presented cases, preparing the acrylic resin straight on the operating table. The resin, moulded and adapted to the defect until its complete hardening, presents, thanks to its properties, manifold advantages (and few real disadvantages). RESULTS: The results, in terms of complications, are very satisfactory, with an infectious rate of 2.7%. Besides, in one third of the patients, a considerable clinical improvement after the repair has been observed. CONCLUSIONS: According to personal experience, it is possible to affirm that polymethylmethacrylate, with its remarkable plasticity and stability in time, can always guarantee a satisfactory functional and aesthetic result.

Adolescent↗