Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “phasing”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Solid-phase extraction and reversed-phase high-performance liquid chromatographic technique for isolation and estimation of platelet activating factor in plasma.

A solid-phase extraction technique for the isolation of platelet activating factor [1-O-alkyl-2-acetyl-sn-glycero-3-phosphocholine (AGEPC)] from biological matrices was developed. Amberlite XAD-2 was effective in retaining different molecular species of AGEPC from plasma and incubation media. The recovery of the three molecular species (C14-, C16-, and C18-AGEPC) was greater than 95%. XAD-2 also removed large amounts of plasma impurities, giving a cleaner high-performance liquid chromatographic (HPLC) profile. AGEPC in plasma or incubation media was not significantly removed by passage of the sample through a column packed with ODS-silica. A reversed-phase HPLC technique for separation and estimation of different species of AGEPC was developed. Resolution of C14-, C16- and C18-AGEPC was accomplished on a Hamilton PRP-1 resin column using an aqueous acetonitrile gradient containing 1 mM methanesulphonic acid. The detection limit was of the order of 50 ng of AGEPC at 210 nm. The AGEPC purified by the technique described retained its biological activity as determined by its ability to release endogenous serotonin from rabbit platelets.

Chromatography, High Pressure Liquid↗

Determination of ketorolac in human plasma by reversed-phase high-performance liquid chromatography using solid-phase extraction and ultraviolet detection.

An improved high-performance liquid chromatographic method has been developed to measure human plasma concentrations of the analgesic nonsteroidal anti-inflammatory drug ketorolac for use in pharmacokinetic studies. Samples were prepared for analysis by solid-phase extraction using Bond-Elut PH columns, with nearly complete recovery of both ketorolac and the internal standard tolmetin. The two compounds were separated on a Radial-Pak C18 column using a mobile phase consisting of water-acetonitrile-1.0 mol/l dibutylamine phosphate (pH 2.5) (30:20:1) and detected at a UV wavelength of 313 nm. Using only 250 microl of plasma, the standard curve was linear from 0.05 to 10.0 microg/ml.

Adolescent↗

A simple method for the assay of colistin in human plasma, using pre-column derivatization with 9-fluorenylmethyl chloroformate in solid-phase extraction cartridges and reversed-phase high-performance liquid chromatography.

A simple, selective and sensitive high-performance liquid chromatographic (HPLC) method is described for the determination of colistin in human plasma. Derivatization with 9-fluorenylmethyl chloroformate was performed in the same solid-phase extraction C18 cartridge used for sample pre-treatment, followed by reversed-phase HPLC with fluorimetric detection. Quantification was achieved using the ratio of the summed peak areas of colistin A and B derivatives to that of the derivative of netilmicin (internal standard). Linear calibration curves were obtained within the concentrations of colistin sulfate from 0.10 to 4.0 mg/l in plasma. Accuracy was within 10% and reproducibility (RSD) was less than 10%.

Calibration↗

Identification of phase I and phase II metabolites of ketobemidone in patient urine using liquid chromatography-electrospray tandem mass spectrometry.

Ketobemidone and five of its phase I metabolites were identified in the urine of four patients post intravenous administration of Ketogan Novum. Furthermore, indications of the presence of the glucuronide conjugates of ketobemidone and norketobemidone is presented. Both hydrolyzed (beta-glucuronidase) and unhydrolyzed human urine was extracted on a mixed-mode slightly polar cation-exchange SPEC cartridge prior to analysis with LC-ESI-MS-MS. The phase I metabolites were identified by comparison of their daughter spectra with those of synthesized standards. The glucuronides were identified by their molecular mass and interpretation of the daughter spectra, as no standards were available for these compounds.

Analgesics, Opioid↗

Simultaneous determination of a novel calcium entry blocker, monatepil maleate, and its metabolites in rat plasma by means of solid-phase extraction and reversed-phase liquid chromatography with electrochemical detection.

A reversed-phase LC method with electrochemical detection is described for the simultaneous determination of monatepil maleate (AJ-2615, AJ), a novel calcium entry blocker, and its three S-oxidized metabolites in plasma. These compounds were extracted from plasma by solid-phase extraction and injected onto an ODS column. The determination limit in plasma (0.5 ml) was 10 ng/ml for AJ and 5 ng/ml for the three metabolites. The method was applied to the determination of AJ and the metabolites in rat plasma samples.

Animals↗

Role of Fourier transform infrared spectroscopy in the rehearsal phase of combinatorial chemistry: a thin-layer chromatography equivalent for on-support monitoring of solid-phase organic synthesis.

The adaptation of diverse organic reactions to solid supports requires significant reaction optimization efforts. A convenient on-support analytical method functionally similar to TLC in solution chemistry is very advantageous. As a TLC-equivalent method, the single bead FTIR is a simple, sensitive, fast, and convenient analytical method to monitor SPOS without stopping the reaction or cleaving the product. As with TLC, single bead FTIR provides a wide range of information such as qualitative assessment, quantitative determination, and reaction kinetics. Studies with the single bead FTIR have not only provided a tool for daily monitoring of the solid-phase reactions, but a way to understand the properties of polymer-bound substrate and the nature of polymer-supported organic reactions. It has assisted in the selection of a wide range of reaction conditions rapidly for SPOS in the rehearsal phase of combinatorial chemistry. Due to its convenience and efficiency, FTIR internal reflection spectroscopy has evolved as a useful analytical methodology for monitoring of combinatorial chemistry reactions directly on polymer surface.

Chemistry, Pharmaceutical↗

Simultaneous assay of morphine, morphine-3-glucuronide and morphine-6-glucuronide in human plasma using normal-phase liquid chromatography-tandem mass spectrometry with a silica column and an aqueous organic mobile phase.

Morphine (MOR) is an opioid analgesic used for the treatment of moderate to severe pain. MOR is extensively metabolized to morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). A rapid and sensitive method that was able to reliably detect at least 0.5 ng/ml of MOR and 1.0 ng/ml of M6G was required to define their pharmacokinetic profiles. An LC-MS-MS method was developed in our laboratory to quantify all three analytes with the required sensitivity and a rapid turnaround time. A solid-phase extraction (SPE) was used to isolate MOR, M3G, M6G, and their corresponding deuterated internal standards from heparinized plasma. The extract was injected on a LC tandem mass spectrometer with a turbo ion-spray interface. Baseline chromatographic separation among MOR, M3G, and M6G peaks was achieved on a silica column with an aqueous organic mobile phase consisting of formic acid, water, and acetonitrile. The total chromatographic run time was 3 min per injection, with retention times of 1.5, 1.9 and 2.4 min for MOR, M6G, and M3G, respectively. Chromatographic separation of M3G and M6G from MOR was paramount in establishing the LC-MS-MS method selectivity because of fragmentation of M3G and M6G to MOR at the LC-MS interface. The standard curve range in plasma was 0.5-50 ng/ml for MOR, 1.0-100 ng/ml for M6G, and 10-1000 ng/ml for M3G. The inter-day precision and accuracy of the quality control (QC) samples were <7% relative standard deviation (RSD) and <6% relative error (R.E.) for MOR, <9% RSD and <5% R.E. for M6G, and <3% RSD and <6% R.E. for M3G. Analyte stability during sample processing and storage were established. Method ruggedness was demonstrated by the reproducible performance from multiple analysts using several LC-MS-MS systems to analyze over one thousand samples from clinical trials.

Chromatography, Liquid↗

Simultaneous determination of SU5416 and its phase I and phase II metabolites in rat and dog plasma by LC/MS/MS.

SU5416, Z-3-[(2,4-dimethylpyrrol-5-yl)methylidenyl]-2-indolinone, is a cytostatic substance in development as an anti-angiogenic agent. SU5416 has several phase I and phase II metabolites including SU9838, SU6595, SU6689, 5'-hydroxy glucuronide of SU5416 and 5'-acyl glucuronide of SU5416. In order to support the preclinical studies, a liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) method for simultaneous determination of SU5416 and its metabolites in rat and dog plasma was developed. This method is fast, simple, sensitive (LOQ=2.0 ng/ml), reproducible and has a wide linear range (2.0-5000 ng/ml for SU5416, 2.0-2000 ng/ml for SU6689 and 2.0-1000 ng/ml for SU9838 and SU6595). This method was applied to rat and dog plasma samples obtained from pharmacokinetic and toxicokinetic studies.

Angiogenesis Inhibitors↗

Comparison of reversed phase and reversed phase ion pair high performance liquid chromatography for analysis of TcO and TcN complexes of L,L-ethylene dicysteine di-ethylester and its acid analogues.

99mTc(V)-oxo complexes of L,L-ethylene dicysteine (L,L-EC) and its di-ester derivative L,L-ethyl cysteinate dimer (L,L-ECD) are useful tracer agents for evaluation of renal function and cerebral blood flow respectively. Labelling of these molecules with a 99mTc(V)-nitrido core instead of the 99mTc(V)-oxo core alters their biological and physiochemical behavior. In the reversed phase high performance liquid chromatography (HPLC) method presently used to analyse 99mTc(V)-oxo preparations of L,L-EC and L,L-ECD, the 99mTc(V)-nitrido-L,L-EC complex and the possible impurities of a 99mTc(V)-nitrido-L,L-ECD preparation were found to elute with the void volume. In this study, a reversed phase ion pair HPLC method has been developed that is useful for the analysis of both 99mTc(V)-oxo and 99mTc(V)-nitrido preparations of L,L-EC and L,L-ECD. Tetrabutylammonium hydroxide is used as a cationic ion pairing agent.

Chromatography, High Pressure Liquid↗

Stereoselective determination of R(-)- and S(+)-prilocaine in human serum using a brush-type chiral stationary phase, solid-phase extraction and UV detection.

A chiral HPLC method was developed for the quantitation of R(-)- and S(+)-prilocaine in human serum. The method involves sensitive and selective detection of R(-)- and S(+)-prilocaine using normal-phase chiral HPLC on a pirkle-type naphthyl ethylamine stationary phase (Sumichiral OA-4700, 250 mm x 4 mm i.d.) at ambient temperature with a flow rate of 0.8 ml min-1. A sample clean-up procedure was used for isolation of the analytes of interest from human serum using Bond-Elut C18 columns with high recovery and selectivity. The detection limits were 4 ng ml-1 for R-prilocaine and 5 ng ml-1 for S-prilocaine. The limits of quantitation were 10 ng ml-1 for both enantiomers. Linear calibration curves in the 10-1000 ng ml-1 range showed good coefficients of determination > 0.999 (n = 3). Precision and accuracy of the method were within 4-5.8% and 1.5-4.8% respectively for R(-)-prilocaine, and 2.8-5.7% and 3.2-5.2% respectively for S(+)-prilocaine.

Anesthetics, Local↗

Determination of U-89968E, a 5HT1a agonist in rat plasma using solid-phase extraction, precolumn derivatization and reversed-phase high-performance liquid chromatography.

A selective and sensitive HPLC method was developed for the determination of U-39968E in rat plasma. The assay involved solid-phase extraction of the analyte and the internal standard and precolumn derivatization with cyclohexane-1,3-dione reagent before injection on to the HPLC column. The samples were chromatographed on a Spherisorb S5 CN column (25 cm x 4.6 mm i.d.) with a mobile phase containing acetonitrile-trifluoroacetic acid-water (17:0.2:83, v/v/v) at a flow rate of 1.5 ml min-1. The column eluent was monitored by flourescence detection with excitation at 272 nm and emission at 320 nm. The assay is linear over the range 4-759 ng ml-1. The relative standard deviation at the limit of quantification, 4 ng ml-1, was 7.1%. This method was successfully applied to the determination of U-89968E in rat plasma during pharmacokinetic studies.

8-Hydroxy-2-(di-n-propylamino)tetralin↗

It's not just a phase: crystallization and X-ray structure determination of bacteriorhodopsin in lipidic cubic phases.

Utilization of lipidic cubic phases in the crystallization of bacteriorhodopsin (bR) has yielded long sought after crystals that diffract X-rays to 2 A resolution. The resulting structure provides new information on the protein conformation and the mechanism of proton translocation. Crystallization of bR via lipidic cubic phases may be a harbinger of new membrane protein crystallization strategies.

Bacterial Proteins↗

Gas phase RNA and DNA ions 2. Conformational dependence of the gas-phase H/D exchange of nucleotide-5'-monophosphates.

The conformational dependence of the gas-phase hydrogen/deuterium (H/D) exchange of nucleotide-5-monophosphate anions with the H/D exchange reagent D2S is reported here. The electrospray-generated [M-H]- anions of adenosine-5'-monophosphate, adenosine-5'-carboxylic acid, ribitol-5-phosphate, and 2-deoxy-ribitol-5-phosphate were reacted with D2S in the gas phase. Their reactivity (adenosine-5'-monophosphate exchanged 2 of 5 labile hydrogens, adenosine-5'-carboxylic acid exchanged 1 of 4, ribitol-5-phosphate exchanged 2 of 3, and 2-deoxy-ribitol-5-phosphate exchanged 1 of 2) suggests that the hydroxyl group in the 2 position of the ribose sugar and the amino hydrogen on the nucleobase do not exchange readily with D2S. Semiempirical molecular orbital calculations suggest that the labile hydrogens in these positions are thermodynamically facile to exchange but as a conformation inaccessible to the presumed phosphate anion, consistent with a mechanism in which the phosphate anion complexes with the exchange reagent and assists H/D exchange at a neighboring site.

Adenosine↗

Phase transfer and biocatalyst behaviour during biotransformation of beta-ionone in a two-phase liquid system by immobilised Aspergillus niger.

The biotransformation of beta-ionone by Aspergillus niger IFO 8541 entrapped in Ca-alginate beads was investigated in a two-phase liquid system, due to the low aqueous solubility of the precursor. Modelling of phase transfer processes of the substrate demonstrated that the solute was transferred from the organic droplets to the gas, giving a loss by stripping, and then from the gas to the aqueous solution where a chemical degradation occurred. The biological reaction took place after direct precursor transfer from the organic layer to the biocatalyst by surface adsorption. Studies on the biological process demonstrated the critical effect of the biomass content in the medium at the time at which beta-ionone was added. Optimum conditions involved fed-batch feedings of both precursor and carbon source (sucrose) after the biomass concentration reached a value close to 6.8g/l. The biotransformation process then took place at a constant rate of 0.046mmol/lh with a reaction yield, defined with respect to beta-ionone metabolised by the fungus, close to unity. Best results achieved in this study allowed to obtain 3.5g/l biological compounds after 400h reaction.

Journal Article↗

Macroporous polymeric stationary-phase rod as continuous separation medium for reversed-phase chromatography.

A macroporous poly(styrene-co-divinylbenzene) rod has been prepared by a free-radical polymerization of a mixture containing monomers, initiator, and porogenic solvent in the confines of a chromatographic column and used for the first time in the very fast reversed-phase HPLC of proteins. Characterization of the pore structure of the continuous rod by mercury intrusion porosimetry revealed a large volume of pores with a diameter of about 1 micron to pores below 100 nm. Size exclusion chromatography and scanning electron microscopy confirmed the unusual pore size distribution. The presence of large pores make the rod easily permeable to eluents, and therefore, the back pressure of the rod column is modest even at high flow rates. The efficiency of the polymerized column is almost independent of the flow rate. The slope of the line showing capacity factor vs composition of the mobile phase was determined for several proteins, and a gradient for the separation of their mixtures was developed. Excellent separation was achieved even at a high flow rate of 25 mL/min as documented by the resolution data. Tripling the length of the column did not improve the column resolution in protein separation.

Chromatography, High Pressure Liquid↗

Direct determination of substituted azepinoindole enantiomers in rat plasma using silica stationary phase and beta-cyclodextrin as a mobile phase additive.

DU 124884 is a racemic serotonin receptor agonist in an early stage of drug development. DU 124884 and its potential N-desmethyl metabolite, KC 9048, both contain a single chiral center. A direct enantioselective HPLC assay was developed and validated to quantify DU 124884 and KC 9048 in rat plasma. The drug and metabolite enantiomers were extracted from plasma and separated using silica stationary phase with an aqueous mobile phase containing beta-cyclodextrin (beta-CD), triethylamine, and 2-methyl-2-propanol. A variable wavelength detector was used to monitor absorbance at 231 nm. The assay calibration range was from 100 to 5000 ng/mL. Quality control sample precision (< or = 9% RSD) and accuracy (+/-10% error) were satisfactory for all four analytes (n = 12). The method was used to assess drug exposure during a pilot toxicology study in rats. Toxicokinetic study animals were dosed subcutaneously for 15 days at 0, 2.5, 10, and 40 mg of DU 124884.HCl kg-1 day-1. Blood was collected on the last day of dosing between 22 min and 4 h and 13 min after the last dose. The samples showed (+/-)-DU 124884 isomer ratios ranging from 1.1 to 1.3. These data suggest that DU 124884 undergoes stereoselective metabolism in rats. Levels of the N-desmethyl metabolite enantiomers were < 100 ng/mL.

Animals↗

Determination of clenbuterol in bovine liver by combining matrix solid-phase dispersion and molecular imprinted solid-phase extraction followed by liquid chromatography/electrospray ion trap multiple-stage mass spectrometry.

Matrix solid-phase dispersion (MSPD) is a new sample pretreatment for solid samples. This technique greatly simplifies sample pretreatment but, nonetheless, the extracts often still require an extra cleanup step that is both laborious and time-consuming. The potential of combining MSPD with molecularly imprinted solid-phase extraction (MISPE) was investigated in this study. Liver samples were ground in a mortar with C18 sorbent and the homogenized mixture packed into an SPE cartridge and placed on top of a MISPE cartridge. Subsequently, clenbuterol was eluted from the MSPD cartridge onto the MISPE cartridge using acetonitrile containing 1% acetic acid. The ability of the molecularly imprinted polymer to selectively adsorb analyte in acetonitrile was exploited for re-extracting clenbuterol directly from this acetonitrile extract via the double cartridge tandem system. The analyte was eluted from the MISPE cartridge using acidified methanol. A clear eluate was obtained, which was subsequently evaporated, redissolved, and analyzed by HPLC electrochemical detection (ECD) or ion trap mass spectrometry (LC/IT-MS). The MISPE cartridge used in this study was imprinted using bromoclenbuterol, a structural analogue of clenbuterol, as the template. These MISPE cartridges showed excellent stability. The complete extraction procedure was rapid, and recoveries exceeded 90% for the target analyte. The method detection limit for the LC/IT-MS procedure was < 0.1 microg/kg. This method, therefore, satisfies the stringent requirements of European Union regulation EEC 2377/90.

Adrenergic beta-Agonists↗

Use of 1.5-microm porous ethyl-bridged hybrid particles as a stationary-phase support for reversed-phase ultrahigh-pressure liquid chromatography.

A new ethyl-bridged hybrid packing material was evaluated in terms of its suitability for ultrahigh-pressure liquid chromatography (UHPLC). The 1.5-microm particles were obtained and packed into 30-microm-i.d. fused-silica capillary columns up to 50 cm in length. The particles were evaluated by isocratic reversed-phase UHPLC at pressures up to 4500 bar (65,000 psi). The chromatographic performance of these particles was found to be similar to the performance of 1.0-microm nonporous silica particles. The mechanical strength of the ethyl-bridged hybrid material was evaluated by running a 15-cm-long column at pressures up to 4500 bar. No breakdown of the particles in the packed bed was observed. The sample loading capacity of the hybrid material was evaluated and compared to 1.0-microm nonporous silica material by observing analyte peak width versus amount injected. The observed improvement in loading capacity for the hybrid material versus nonporous silica was consistent with the improvement predicted by comparing the phase ratios of the two materials.

Journal Article↗