Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VENTILATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Unloadiing of the work of breathing by proportional assist ventilation in a lung model.

OBJECTIVES: Proportional assist ventilation is devised to increase airway pressure in proportion to inspiratory effort. A systematic study of the performance of this new mode of ventilation has not been presented. We tested in the laboratory the capability of proportional assist ventilation to unload the work of breathing in proportion to ventilatory drive, under a variety of mechanical loads. DESIGN: During variations of "ventilatory drive" (i.e., tidal volume), unloading of the work of breathing by proportional assist ventilation was contrasted with unloading by pressure-support ventilation. SETTING: The respiratory laboratory of a university-affiliated teaching hospital. SUBJECT: A bellows-in-a-box lung model, powered by a sine wave air flow generator. INTERVENTIONS: Proportional assist and pressure-support ventilation were preset to provide comparable support at a baseline "ventilatory drive" of 0.7-L tidal volume. The set levels of proportional assist and pressure-support ventilation were subsequently applied to five tidal volumes, from 0.2 to 1.2 L. Three levels of inspiratory support and three settings of mechanical load were evaluated. MEASUREMENTS AND MAIN RESULTS: Proportional assist ventilation significantly (p < .05) reduced the work of breathing of the lung model at all but the lowest tidal volume (0.2 L). The preset proportion of ventilatory support (30%, 50%, and 70%) unloaded the work of breathing uniformly as ventilatory drive was varied at tidal volumes of > or = 0.5 L, but not always at tidal volumes of < or = 0.4 L. In contrast, pressure-support ventilation overassisted low tidal volumes and underassisted high tidal volumes (p < .05). CONCLUSIONS: In a lung model, a prototype system delivering proportional assist ventilation provided uniform unloading of the work of breathing as the ventilatory drive was varied within a tidal volume range of 0.5 to 1.2 L. These findings confirm the theoretical modeling of proportional assist ventilation. This system, however, failed to properly unload low tidal volumes of 0.2 to 0.4 L.

Humans↗

Partial liquid ventilation with perflubron attenuates in vivo oxidative damage to proteins and lipids.

OBJECTIVE: To determine the impact of partial liquid ventilation on the degree of pulmonary damage by reactive oxygen species in a model of acute lung injury caused by systemic endotoxemia. DESIGN: A prospective, controlled, in vivo, animal laboratory study. SETTING: Animal research facility of a health sciences university. SUBJECTS: Forty New Zealand White rabbits. INTERVENTIONS: Mature rabbits were anesthetized and instrumented with a tracheostomy and vascular catheters. Animals were assigned to receive either partial liquid ventilation (n = 16) with perflubron (18 mL/kg via endotracheal tube) or conventional mechanical ventilation (n = 16). Both groups were ventilated using similar strategies, with an Fio2 of 1.0 and tidal volume as required to obtain a normal Paco2. Animals were then given 0.9 mg/kg Escherichia coli endotoxin intravenously over 30 mins. Eight uninjured instrumented and mechanically ventilated animals served as controls. Partial liquid ventilation or conventional ventilation was continued for 4 hrs before the animals were killed. Lung homogenates were analyzed for malondialdehyde (MDA) and 4-hydroxy-2(E)-nonenal (4-HNE) concentrations using a colorimetric assay. To assess protein oxidative damage, carbonyl groups in protein side chains were derivatized with 2,4-dinitrophenylhydrazine followed by Western blotting with a dinitrophenylated-specific primary antibody. MEASUREMENTS AND MAIN RESULTS: MDA (713.42+/-662 vs. 1601.4+/-1156 nmol/g protein; p = .023) and MDA plus 4-HNE (1480.24+/-788 vs. 2675.2+/-1628 nmol/g protein; p = .038) concentrations were lower in animals treated with partial liquid ventilation compared with conventionally ventilated animals, respectively. Animals treated with partial liquid ventilation exhibited attenuation of dinitrophenylated-derivatized protein bands by Western blotting, indicating a reduction in protein oxidative damage. The presence of perfluorocarbon did not interfere with the MDA assay when assessed by independent analysis in vitro. Perflubron did not serve as a sink for peroxyl radicals produced in the aqueous phase during separate in vitro oxidation experiments. CONCLUSIONS: Partial liquid ventilation attenuates oxidative damage to lipids and proteins during experimental acute lung injury. This finding is not caused by binding of lipid peroxidation products to perflubron or by the peroxyl radical scavenging properties of perflubron.

Animals↗

New model of ventilator-associated pneumonia in immunocompetent rabbits.

OBJECTIVE: Despite the high rate of therapeutic failures in ventilator-associated pneumonia, up to now there has been no animal model specifically designed for antimicrobial evaluation. A rabbit model of ventilator-associated pneumonia is described for the first time in this study. DESIGN Prospective, randomized experimental study. SETTING: An animal research laboratory. SUBJECTS: Male New Zealand healthy rabbits (n = 44). INTERVENTIONS: After oral intubation and an hour of mechanical ventilation, animals in the ventilator-associated pneumonia group (n = 22) were infected intrabronchially with a calibrated inoculum of. The nonventilated pneumonia group (n = 22) was composed of animals that received the same inoculum in the absence of mechanical ventilation. Rabbits from both groups were randomly killed 3, 6, 12, 24, or 48 hrs after inoculation. Pneumonia evaluation was based on histologic (macroscopic and microscopic score) and bacteriologic (bacterial count) findings. MAIN RESULTS: Infected animals undergoing mechanical ventilation rapidly developed a progressive bilateral and multifocal pneumonia. Lung bacterial mean (sd) concentration was 6.48 (0.71) log10 colony-forming units (cfu) per gram of tissue at the 48th hour, whereas bacteremia occurred in most cases. In the nonventilated pneumonia group, pneumonia was less severe in terms of bacterial count (3.18 [1.86] log10 cfu/g; p <.05), and spleen cultures remained negative. In addition, microscopic examination revealed noninfectious lung injury in the ventilator-associated pneumonia group, especially hyaline membrane filling alveolar spaces. Of note, these features were never observed in the nonventilated pneumonia group. CONCLUSIONS: An animal model of ventilator-associated pneumonia was obtained in immunocompetent rabbits. Histopathologic and bacteriologic features were similar to those found in humans. Obviously, pneumonia was more severe when animals underwent mechanical ventilation, especially in terms of systemic spread. Noninfectious lung injury corresponding to ventilation-induced lung injury may explain the difference. This model emphasizes the strong impact of both mechanical ventilation and infection on lung because they seem to act synergistically when causing alveolar damage. Moreover, it seems well suited to testing antimicrobial effectiveness.

Animals↗

Pulmonary antioxidant enzyme activity during early development: Effect of ventilation.

OBJECTIVE: To examine the effect of tidal liquid ventilation (TLV) and conventional gas ventilation (GV) on the pulmonary antioxidant enzyme (AOE) activity in two groups of preterm lambs at 110 and 120 days of gestation and to compare these results to age-matched fetal controls. DESIGN: Experimental, prospective, randomized, controlled study. SETTING: School of medicine, department of physiology. SUBJECTS: Thirty-two premature lambs at 110 days (n = 16) and 120 days (n = 16) gestation. INTERVENTIONS: Six lambs at 110 and 120 days were ventilated with TLV for 4 hrs. Three lambs at 110 days were ventilated with GV for 3 hrs, and six lambs at 120 days were ventilated with GV for 4 hrs. Four lambs, each at 110 and 120 days, were used as age-matched fetal controls. Measurements: Sequential measurements of arterial blood chemistries were performed in all groups. Biochemical assays included catalase activity, superoxide dismutase activity, and glutathione peroxidase activity. Histologic examinations of lung sections from TLV and GV lungs were performed. Main Result: Despite vast differences in physiologic outcome, there were fewer differences in AOE activity as a function of ventilation (fetal control, GV, and TLV lambs) and/or gestational age. There were no significant differences in superoxide dismutase and glutathione peroxidase activity as a function of age or ventilation. Catalase activity was significantly higher (p <.05) in fetal 120-day control lambs (24.8 +/- 1.9 units/mg protein) relative to the 110-day control lambs (14.3 +/- 1.7 units/mg protein). Catalase activity significantly (p <.05) decreased in both GV and TLV 120 day lambs compared with fetal controls; yet, in the 110-day gestational lambs, there were no significant differences in enzyme level as a function of ventilation. Thus, an age-specific response to ventilation was evident for catalase activity. CONCLUSION: The present data demonstrate several developmental differences in AOE activity. The lack of ventilation effect in AOE activity, in view of the big difference in physiologic and inflammatory outcomes, suggests that mechanisms associated with free radicals do not underlie the response to different modes of ventilation.

Journal Article↗

Airway pressure release ventilation in pediatrics.

OBJECTIVES: The purpose of this study was to determine the effectiveness of airway pressure release ventilation in children. DESIGN: Prospective, randomized, crossover clinical trial. SETTING: This study was conducted in our 33-bed pediatric intensive care unit at The Children's Hospital of Philadelphia. PATIENTS: Patients requiring mechanical ventilatory support and weighing >8 kg were considered for enrollment. Patients were excluded if they required mechanical ventilatory support for >7 days or required >.50 Fio(2) for >7 days before enrollment. Patients with documented obstructive airway disease and congenital or acquired heart disease were excluded as well. INTERVENTIONS: Each patient received both volume-controlled synchronized intermittent mechanical ventilation (SIMV) and airway pressure release ventilation (APRV) via the Drager Evita ventilator (Drager, Lubeck, Germany). Measurements were obtained after the patient was stabilized on each ventilation mode. Stabilization was defined as oxygenation, ventilation, hemodynamic variables, and patient comfort within the acceptable range for each patient as determined by the bedside physician. After measurements were obtained on the initial mode of ventilation, the subjects crossed over to the alternative study mode. Stabilization was again achieved, and measurements were repeated. After completion of the second study measurements, patients were placed on the ventilation modality preferred by the bedside clinician and were followed through weaning and extubation. Measurements: Vital signs, airway pressures, minute ventilation, Spo(2), and E(T)CO(2) were recorded at enrollment and at each study condition. MAIN RESULTS: APRV provided similar ventilation, oxygenation, mean airway pressure, hemodynamics, and patient comfort as SIMV. Inspiratory airway pressures were lower with APRV when compared with SIMV. CONCLUSIONS: Using APRV in children with mild to moderate lung disease resulted in comparable levels of ventilation and oxygenation at significantly lower inspiratory peak and plateau pressures. Based on these findings, we plan to evaluate APRV in children with significant lung disease.

Journal Article↗

Factors predicting ventilator-associated pneumonia recurrence.

OBJECTIVE: To determine the factors associated with ventilator-associated pneumonia recurrence in patients alive after 8 days of treatment for a first episode. DESIGN: A 16-month, prospective, observational cohort study of patients diagnosed with a first ventilator-associated pneumonia episode. Predictors of recurrence were assessed by logistic regression analysis. SETTING: Two intensive care units in a university hospital. PATIENTS: Bronchoscopy was performed in 124 patients with clinically or radiologically suspected ventilator-associated pneumonia. Ventilator-associated pneumonia was confirmed by the presence of at least two of the following criteria: >/=2% of cells with intracellular bacteria found on direct examination of bronchoalveolar lavage fluid, protected specimen brush sample culture >/=103 colony-forming units/mL, or bronchoalveolar lavage culture >/=104 colony-forming units/mL. Ventilator-associated pneumonia recurrence was confirmed using the same microbiological criteria. Antibiotic treatment for ventilator-associated pneumonia lasted 14 days. MEASUREMENTS AND MAIN RESULTS: Clinical, radiologic, and biological data at intensive care unit admission, on the day of bronchoscopy (D1) and on D8, and outcome variables were prospectively recorded. Ventilator-associated pneumonia recurred in 28 patients (all of them still on mechanical ventilation on D8), 21 +/- 9 days after the first episode (82% after D14). Factors significantly associated with recurrence were: acute respiratory failure as initial reason for mechanical ventilation, D1 radiologic score >7, D8 radiologic score >8, adult respiratory distress syndrome on D8, mechanical ventilation persistence on D8, D8 temperature >38 degrees C, and D8 temperature >D1 temperature, but not disease-severity scores at inclusion and D8, or first-episode pathogen(s). Multivariate analysis identified D1 radiologic score >7 (odds ratio = 3.9; 95% confidence interval, 1.3-11.6), D8 temperature >38 degrees C (odds ratio = 4.4; 95% confidence interval, 1.4-13.4), and adult respiratory distress syndrome on D8 (odds ratio = 14.6; 95% confidence interval, 1.5-143.5) as predictors of recurrence. CONCLUSIONS: Factors of ventilator-associated pneumonia recurrence evaluated on D8 of a 14-day course of antibiotics are linked to the severity of lung injury and persistence of fever, but not to first-episode pathogen(s).

Cross Infection↗

Open lung ventilation improves gas exchange and attenuates secondary lung injury in a piglet model of meconium aspiration.

OBJECTIVE: Previous studies failed to show clear benefits of high-frequency ventilation compared with conventional positive pressure ventilation (PPV(CON)) in experimental meconium aspiration syndrome. However, none of these studies applied an open lung ventilation strategy (OLC), which aims to reduce intrapulmonary shunt due to alveolar collapse. We hypothesized that, if combined with an open lung strategy, both high-frequency oscillatory ventilation (HFOV(OLC)) and positive pressure ventilation (PPV(OLC)) would improve gas exchange and attenuate ventilator-induced lung injury in experimental meconium aspiration syndrome. DESIGN: Prospective, randomized animal study. SETTING: Research laboratory of a large university. SUBJECTS: Forty-two newborn piglets. INTERVENTIONS: Thirty minutes after intratracheal meconium instillation, 36 newborn piglets were assigned to one of three ventilation groups-PPV(OLC), HFOV(OLC), or PPV(CON)-and ventilated for 5 hrs. In both OLC groups, collapsed alveoli were actively recruited and thereafter stabilized using the lowest possible airway pressures. During PPV(CON), ventilator settings were adjusted to prevent critical hypoxia (Pao2 <60 torr [8 kPa]). Six animals served as saline controls. MEASUREMENTS AND MAIN RESULTS: Compared with the PPV(CON) group, arterial oxygenation and lung mechanics were superior in both OLC groups and the saline controls. Analysis of the bronchoalveolar lavage fluid obtained after 5 hrs of ventilation showed increased myeloperoxidase activity in the PPV(CON) group compared with both OLC groups and saline controls. Alveolar protein influx was not different between the groups. Histologic analysis revealed a higher lung injury score in the PPV(CON) group compared with the PPV(OLC) and the HFOV(OLC) groups. CONCLUSIONS: Application of the OLC during PPV and HFOV is feasible in experimental meconium aspiration syndrome and results in superior oxygenation and less ventilator-induced lung injury compared with PPV(CON).

Animals↗

Controlled ventilation enhances catheter stability during radiofrequency ablation.

Variations in the amplitude of the atrial and ventricular depolarization waves of the intracardiac electrogram occur during different phases of respiration. Therefore, we tested whether controlled ventilation would reduce ablation attempts and increase the rate of success in patients undergoing radiofrequency ablation with general anesthesia. Thirty-eight children were divided into two groups: (1) controlled and (2) noncontrolled or cyclic ventilation. In the controlled ventilation group, the mapping electrogram was recorded during sustained inspiration, sustained expiration, and cyclic ventilation. Ablation was done in the phase of ventilation that had the least variability in atrial and ventricular amplitudes. Seventeen patients in the controlled ventilation group had tracings adequate for review. In eight patients, ablation was done during sustained inspiration with the percentage change of atrial and ventricular amplitudes (15% +/- 16% and 13% +/- 16%, respectively) being < that during sustained expiration (38% +/- 27%, P = 0.04 and 20% +/- 21%) or during cyclic ventilation (57% +/- 27%, P < 0.01 and 54% +/- 26%, P = 0.003). In nine patients, ablation was done during sustained expiration with the percentage change of atrial and ventricular amplitudes (5% +/- 5% and 5% +/- 2%) being less than that during sustained inspiration (21% +/- 14%, P = 0.01 and 11% +/- 6%, P = 0.01) or during cyclic ventilation (68% +/- 23%, P < 0.001 and 48 +/- 26%, P = 0.001). We achieved success with each patient in both groups, but the number of ablation attempts were less in the controlled ventilation group 1 (3 +/- 2), as compared to the cyclic ventilation group 2 (8 +/- 8; P < 0.02). We concluded that controlled ventilation reduced the number of ablation attempts and facilitated the ablation procedure.

Adolescent↗

Level of ventilation influences the cardiovascular response to hypoxemia in lambs.

Newborn animals of a number of species display a brisk increase in ventilation followed by a gradual drop toward or below baseline within minutes of exposure to acute hypoxemia. Heart rate and cardiac output (a determinant of systemic oxygen transport along with the arterial oxygen content) appear to follow a similar pattern, but whether or not the cardiovascular response is influenced by the respiratory response is unknown. We therefore carried out experiments in which the level of ventilation was controlled during normoxemia and hypoxemia to test the hypothesis that the level of ventilation influences the cardiovascular response to acute hypoxemia. Six lambs ranging in age from 17 to 22 days were anesthetized, tracheostomized, and instrumented for measurement of cardiovascular variables. A recovery period of at least 3 days was allowed before the study when each lamb was artificially ventilated with a mixture of 70% nitrous oxide and 30% oxygen in nitrogen. A control respiratory frequency (f) of 30 breaths per min was set and a control tidal volume (VT) was chosen to achieve normocapnia. Cardiovascular measurements were made during normoxemia and hypoxemia (FIO2 0.10) 5 min after f or VT was changed to simulate a decrease, no change, or an increase in ventilation. During normoxemia, the level of ventilation had little effect on the measured cardiovascular variables. At control levels of ventilation, hypoxemia caused an increase in cardiac output that was due solely to an increase in stroke volume as heart rate decreased; blood pressure was unchanged. Increasing ventilation during hypoxemia did not augment cardiac output or alter blood pressure as compared with that observed at control levels of ventilation. Decreasing ventilation during hypoxemia, however, decreased cardiac output due to a profound bradycardia; blood pressure increased significantly. Our data provide evidence that the level of ventilation significantly influences the cardiovascular response to hypoxemia in young lambs.

Animals↗

O2 radicals mediate reperfusion lung injury in ischemic O2-ventilated canine pulmonary lobe.

This study was undertaken to determine whether lung injury after a period of ischemia reperfusion is caused by O2 ventilation during ischemia and whether this injury is mediated by reactive O2 metabolites. Isolated canine left lower pulmonary lobes were subjected to room temperature ischemia for 6 h while being ventilated with either 100% O2, room air, or 100% N2. After the ischemic period, all lobes were perfused with autologous blood and ventilated with 100% O2 for an additional 4 h. In lobes ventilated with 100% O2 during the ischemic period, massive weight gain (228%) occurred 4 h after reperfusion. A marked increase in pulmonary shunt was noted. Lobes ventilated with room air behaved similarly. In contrast, lobes ventilated with 100% N2 gained significantly less weight (54%) and did not manifest any increase in pulmonary shunt. When lobes ventilated with 100% O2 or room air were pretreated with superoxide dismutase (SOD), the injury was significantly reduced. Pressure-volume deflation study of lobes, after ischemia only, demonstrated that ventilation with 100% O2 and with 100% N2 both equally decreased pulmonary compliance. We conclude that lung ischemia-reperfusion injury is related to O2 ventilation during ischemia and that injury can be prevented by administration of SOD or ventilation with 100% N2. This suggests that the injury is related to O2 metabolites produced during O2 ventilation in the absence of the circulation.

Animals↗

Self-control and external control of mechanical ventilation give equal air hunger relief.

Elevated end-tidal partial pressure of CO2 (PET(CO2)) causes air hunger; this sensation becomes intense with a relatively small rise in PET(CO2) if ventilation is held constant. Spontaneously breathing subjects increase ventilation in response to CO2, thereby greatly diminishing air hunger. In healthy subjects and ventilator-dependent patients, experimenter-induced increases in ventilator tidal volume (VT) relieve air hunger even if PET(CO2) is kept elevated. We addressed two questions: (1) Can paralyzed, ventilator-dependent patients use the sensation of air hunger to effectively control ventilator VT using nonrespiratory motor pathways; and (2) Do subjects obtain more relief when in control of their own ventilator? Four subjects were trained to increase ventilator VT using a mouth-operated switch. Subjects' ratings of air hunger intensity in response to elevated PET(CO2) were compared during three conditions: (1) constant VT; (2) subject-controlled VT; and (3) experimenter-controlled VT. When given control of their ventilator, all subjects increased VT in response to increased PET(CO2), thereby relieving air hunger. Air hunger relief was similar when the experimenter mimicked these VT changes. These results suggest that: (1) ventilator-dependent patients can use sensation, conscious decisions, and nonrespiratory motor pathways to achieve an appropriate respiratory response to increased PCO2 and (2) control of one's own ventilation is unimportant in these circumstances.

Female↗

Effects of ventilation style on surfactant metabolism and treatment response in preterm lambs.

We investigated whether the style of ventilation would influence respiratory physiology or surfactant metabolism in surfactant-treated preterm lambs. Preterm lambs were delivered at 131 +/- 1 d gestation and treated with an organic solvent extract of sheep surfactant (100 mg/kg). The lambs were randomized to ventilation peiods of 2 h, 5 h, 10 h, or 24 h, and to ventilation with a low rate (15 breaths/min) and high VT (15 ml/kg), with a high rate (50 breaths/min) and low VT (8 ml/kg), or with high-frequency oscillatory ventilation (HFOV). Gas exchange and lung volumes were similar across time and for the different ventilation styles. Saturated phosphatidylcholine (SatPC) in alveolar lavage was lower for the HFOV group than for the other ventilation groups at 10 h and 24 h. The rate of loss of surfactant protein B (SP-B) from these preterm animals' lungs was slow and not influenced by ventilation style. The percentages of surfactants in large-aggregate forms were not changed by style of ventilation, and the large-aggregate surfactants had excellent function when tested in surfactant-deficient preterm rabbits. Alveolar lavage protein was low (30 ml/kg), and tissue hyaluronan did not change with time or ventilation style. In preterm lambs ventilated without causing injury, the extreme styles of ventilation examined in the study had minimal effects on lung function, surfactant function, or surfactant metabolism.

Animals↗

Comparison between tube compensation and pressure support ventilation techniques on respiratory mechanics.

In the intubated patient, the presence of an endotracheal tube increases the work of breathing during spontaneous breathing. The tube compensation technique was developed as a new ventilator mode that can compensate for that additional the work of breathing. We investigated the respiratory parameters during the pressure support ventilation 0, 5, 10 cmH2O and tube compensation 100% modes of the Puritan Bennett 840 ventilator in ten postoperative patients who had undergone radical surgery for oesophageal cancer. Measurements were performed just before extubation. The tidal volume, respiratory rate and other respiratory parameters were measured with a Ventrak respiratory monitor, and the duty ratio, mean inspiratory flow, and rapid shallow breathing index were calculated. In particular, we performed a comparison between pressure support ventilation 5 cmH2O and tube compensation 100%, because pressure support ventilation 5 cmH2O is the usual ventilating mode before the extubation in our intensive care unit. The tidal volume of pressure support ventilation 10 cmH2O was significantly larger and the respiratory rate was significantly lower than the other three modes. There was no significant difference in the minute volume, tidal volume, and respiratory rate between pressure support ventilation 5 cmH2O and tube compensation 100%. The duty ratio of pressure support ventilation 10 cmH2O was significantly smaller than the other three modes. There was no significant difference in the duty ratio and rapid shallow breathing index between pressure support ventilation 5 cmH2O and tube compensation 100%. It was concluded that the assist levels of pressure support ventilation 5 cmH2O and tube compensation 100% were almost equal for clinical purposes.

Aged↗

The effect of open lung ventilation on right ventricular and left ventricular function in lung-lavaged pigs.

INTRODUCTION: Ventilation according to the open lung concept (OLC) consists of recruitment maneuvers, followed by low tidal volume and high positive end-expiratory pressure, aiming at minimizing atelectasis. The minimization of atelectasis reduces the right ventricular (RV) afterload, but the increased intrathoracic pressures used by OLC ventilation could increase the RV afterload. We hypothesize that when atelectasis is minimized by OLC ventilation, cardiac function is not affected despite the higher mean airway pressure. METHODS: After repeated lung lavage, each pig (n = 10) was conventionally ventilated and was ventilated according to OLC in a randomized cross-over setting. Conventional mechanical ventilation (CMV) consisted of volume-controlled ventilation with 5 cmH2O positive end-expiratory pressure and a tidal volume of 8-10 ml/kg. No recruitment maneuvers were performed. During OLC ventilation, recruitment maneuvers were applied until PaO2/FiO2 > 60 kPa. The peak inspiratory pressure was set to obtain a tidal volume of 6-8 ml/kg. The cardiac output (CO), the RV preload, the contractility and the afterload were measured with a volumetric pulmonary artery catheter. A high-resolution computed tomography scan measured the whole lung density and left ventricular (LV) volumes. RESULTS: The RV end-systolic pressure-volume relationship, representing RV afterload, during steady-state OLC ventilation (2.7 +/- 1.2 mmHg/ml) was not significantly different compared with CMV (3.6 +/- 2.5 mmHg/ml). Pulmonary vascular resistance (OLC, 137 +/- 49 dynes/s/cm5 versus CMV, 130 +/- 34 dynes/s/cm5) was comparable between groups. OLC led to a significantly lower amount of atelectasis (13 +/- 2% of the lung area) compared with CMV (52 +/- 3% of the lung area). Atelectasis was not correlated with pulmonary vascular resistance or end-systolic pressure-volume relationship. The LV contractility and afterload during OLC was not significantly different compared with CMV. Compared with baseline, the LV end-diastolic volume (66 +/- 4 ml) decreased significantly during OLC (56 +/- 5 ml) ventilation and not during CMV (61 +/- 3 ml). Also, CO was significantly lower during OLC ventilation (OLC, 4.1 +/- 0.3 l/minute versus CMV, 4.9 +/- 0.3 l/minute). CONCLUSION: In this experimental study, OLC resulted in significantly improved lung aeration. Despite the use of elevated airway pressures, no evidence was found for a negative effect of OLC on RV afterload or LV afterload, which might be associated with a loss of hypoxic pulmonary vasoconstriction due to alveolar recruitment. The reductions in the CO and in the mean pulmonary artery pressure were consequences of a reduced preload.

Animals↗

Obstacles to discharge of ventilator-assisted children from the hospital to home.

Home care for ventilatory-assisted children improves psychosocial development and reduces medical costs compared with hospital care; yet, many ventilator-assisted children remain hospitalized for lengthy periods of time after they have achieved medical stability. To identify factors that contributed to a delay in hospital discharge from the time medical stability was achieved, we reviewed the records of 54 ventilator-assisted children (age 4.6 +/- 5.9 [SD] years at discharge) who were discharged from the hospital on a regimen of home mechanical ventilation. The length of the hospitalization from which the ventilator-assisted children were initially discharged on the ventilator was 172 +/- 161 days (range, 2 to 756). The time from medical stability to discharge was 118 +/- 144 days (range, 2 to 724), or 73 percent +/- 29 percent of the total hospitalization. Fifty-one ventilator-assisted children were discharged to their natural parents' homes, and three were discharged to foster care. Once ventilator-assisted children were medically stable, it took 99 +/- 141 days for third-party payers to approve home care funding, and only 48 +/- 87 days to be discharged once funding was approved. For the 27 ventilator-assisted children with public funding, it took 184 +/- 177 days for home care funding approval, compared with 52 +/- 43 days for the 27 ventilator-assisted children with private funding (p < 0.001). Parent training took only 52 +/- 65 days. It took 369 +/- 334 days (range, 44 to 711 days) to find placement for the three ventilator-assisted children who were placed in medical foster care. In summary, ventilator-assisted children often remained hospitalized for prolonged periods of time, after they were medically stable, for nonmedical reasons. The greatest obstacle to hospital discharge was seeking approval for home care funding and for arranging out-of-home placement. Public funding agencies took significantly longer to approve home care funding than private insurance agencies.

Adolescent↗

A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients.

STUDY OBJECTIVE: To determine the safety and cost-effectiveness of mechanical ventilation with an extended-use hygroscopic condenser humidifier (Duration; Nellcor Puritan-Bennett; Eden Prairie, Minn) compared with mechanical ventilation with heated-water humidification. DESIGN: Prospective randomized clinical trial. SETTING: Medical and surgical ICUs of Barnes-Jewish Hospital, St. Louis, a university-affiliated teaching hospital. PATIENTS: Three hundred ten consecutive qualified patients undergoing mechanical ventilation. INTERVENTIONS: Patients requiring mechanical ventilation were randomly assigned to receive humidification with either an extended-use hygroscopic condenser humidifier (for up to the first 7 days of mechanical ventilation) or heated-water humidification. MEASUREMENTS: Occurrence of ventilator-associated pneumonia, endotracheal tube occlusion, duration of mechanical ventilation, lengths of intensive care and hospitalization, acquired multiorgan dysfunction, and hospital mortality. RESULTS: One hundred sixty-three patients were randomly assigned to receive humidification with an extended-use hygroscopic condenser humidifier, and 147 patients were randomly assigned to receive heated-water humidification. The two groups were similar at the time of randomization with regard to demographic characteristics, ICU admission diagnoses, and severity of illness. Risk factors for the development of ventilator-associated pneumonia were also similar during the study period for both treatment groups. Ventilator-associated pneumonia was seen in 15 (9.2%) patients receiving humidification with an extended-use hygroscopic condenser humidifier and in 15 (10.2%) patients receiving heated-water humidification (relative risk, 0.90; 95% confidence interval=0.46 to 1.78; p=0.766). No statistically significant differences for hospital mortality, duration of mechanical ventilation, lengths of stay in the hospital ICU, or acquired organ system derangements were found between the two treatment groups. No episode of endotracheal tube occlusion occurred during the study period in either treatment group. The total cost of providing humidification was $2,605 for patients receiving a hygroscopic condenser humidifier compared with $5,625 for patients receiving heated-water humidification. CONCLUSION: Our findings suggest that the initial application of an extended-use hygroscopic condenser humidifier is a safe and more cost-effective method of providing humidification to patients requiring mechanical ventilation compared with heated-water humidification.

Adolescent↗

[Mechanical ventilation in children]

OBJECTIVE: To make a brief review about mechanical ventilation in Pediatrics.METHODS: Review of the classification of types of mechanical ventilation, characteristics of pression and flow waves and indications for its installation. In a sequential way we discuss the various modes of ventilation (control ventilation, assisted-control ventilation, assisted ventilation, intermittent mandatory ventilation, synchronized intermittent mandatory ventilation, pressure-support ventilation) showing some advantages and disadvantages of using these modes. RESULTS: General rules for mechanical ventilation are presented, considering some specific pathologies in Pediatrics (acute respiratory distress syndrome, bronchopleural fistulae, cranial trauma, cardiac failure, neuromuscular pathology, acute asthma and in patients with acute descompensation of a cronic respiratory failure). CONCLUSIONS: Some limitations of mechanical ventilation and the possible advances in a short period are presented.

Journal Article↗

The Mayo Ventilator-Dependent Rehabilitation Unit: a 5-year experience.

OBJECTIVE: To describe the outcomes of 206 patients admitted to the Mayo Ventilator-Dependent Rehabilitation Unit (VDRU) during a 5-year study period. DESIGN: We analyze the patient data for 1990 through 1994, which had been prospectively entered into a computer database for a cohort of 206 patients who had become ventilator dependent during their current hospitalization. MATERIAL AND METHODS: Patients in the VDRU were classified into one of six categories that reflected the reasons for ventilator dependence. Ability to be weaned from mechanical ventilation, duration of hospital stay and ventilator dependence, outcome, disposition, demographics, and long-term survival were analyzed. The VDRU patient group was compared for hospital and follow-up outcomes with a group of historical control patients previously described by us. RESULTS: The Mayo VDRU was established in January 1990. During the first 5 years of its operation, 206 newly ventilator-dependent patients were admitted to the VDRU, 190 (92%) of whom survived to be dismissed; 16 patients (8%) died in the hospital. Of the 190 patients dismissed, 77% were able to return to their homes. Overall, 153 patients were liberated from mechanical ventilation, whereas 37 remained either completely or partially ventilator dependent. Of these 37 patients, 27 (73%) were receiving nocturnal mechanical ventilation only. The 4-year survival was 53%. CONCLUSION: The Mayo VDRU has been highly successful in liberating newly ventilator-dependent patients from mechanical ventilation. The long-term survival after management in the VDRU has been excellent. In addition, the medical charges for care in the VDRU are less than intensive-care unit charges.

Adolescent↗