Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “TECHNETIUM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Prognostic significance of systolic blood pressure changes during dobutamine-atropine stress technetium-99m sestamibi perfusion scintigraphy in patients with chest pain and known or suspected coronary artery disease.

To investigate the prognostic value of dobutamine stress-induced changes in systolic blood pressure (BP) 418 patients (mean age 60 years, 238 men) with chest pain and known or suspected coronary artery disease, who underwent a dobutamine-atropine stress technetium-99m sestamibi myocardial perfusion scintigraphic study, were followed up for 25 +/- 15 months. Blood pressure was measured by automatic sphygmomanometry every 3 minutes. A marked decrease and increase in systolic BP from rest to peak were defined as changes of > or = 20 mm Hg, and > or = 30 mm Hg, respectively. Worst outcome events were cardiac death (n = 30), nonfatal myocardial infarction (n = 17), and hospitalization for congestive heart failure (n = 8). A decrease in systolic BP (prevalence 16%) was associated with older age and higher baseline systolic BP. Fixed and reversible sestamibi perfusion defects and follow-up results were similar to patients without a systolic BP decrease. In contrast, an increase in systolic BP (prevalence 24%) was associated with younger age, lower baseline systolic BP, and with absence of a history of prior congestive heart failure or treatment with angiotensin-converting enzyme inhibitors. Furthermore, these patients had fewer fixed perfusion defects and tended to have fewer annual event rates (3.5% vs 7.5%, p < 0.10). In a multivariate model, an increase in systolic BP was not an independent predictor for subsequent events. In conclusion, a dobutamine-induced decrease in systolic BP is not associated with fixed or reversible sestamibi defects or adverse prognosis. An increase in systolic BP, however, is associated with less fixed sestamibi defects and a tendency toward less annual event rates.

Adrenergic beta-Agonists↗

Usefulness of hemodynamic changes during adenosine infusion in predicting the diagnostic accuracy of adenosine technetium-99m sestamibi single-photon emission computed tomography (SPECT).

Whether adenosine myocardial perfusion single-photon emission computed tomography (SPECT) remains accurate for detecting coronary artery disease (CAD) in the absence of peripheral hemodynamic changes is unknown. To assess the hemodynamic correlates of perfusion defects, we studied 222 consecutive patients (age 71 +/- 11 years) without prior myocardial infarction or revascularization who underwent adenosine technetium (Tc)-99m sestamibi myocardial perfusion SPECT and cardiac catheterization within 6 months of adenosine study. The SPECT protocol used separate acquisition of rest thallium-201 and adenosine Tc-99m sestamibi, which was semiquantitatively analyzed in 20 segments with a visual 5-point scoring system (0 = normal, 4 = absent uptake). The overall sensitivity, specificity, and predictive accuracy of adenosine Tc-99m sestamibi SPECT for detecting significant CAD were 93% (159 of 171), 73% (37 of 51), and 88% (196 of 222), respectively. The study population was grouped into 6 categories as a function of peripheral hemodynamic changes: (1) increase in heart rate by < or = 10 beats/min (n = 135); (2) increase in heart rate by > 10 beats/min (n = 87); (3) decrease in systolic blood pressure by < or = 10 mm Hg (n = 108); (4) decrease in systolic blood pressure by > 10 mm Hg (n = 114); (5) increase in heart rate by < or = 10 beats/min and decrease in systolic blood pressure by < or = 10 mm Hg (n = 72); and (6) increase in heart rate by > 10 beats/min or decrease in systolic blood pressure by > 10 mm Hg (n = 150). The sensitivity, specificity, and predictive accuracy of adenosine sestamibi SPECT were similar in all 6 categories. The prevalence of left main or multivessel CAD and extent of scan abnormality were also similar among all groups. Thus, the diagnostic accuracy of adenosine Tc-99m sestamibi SPECT is high in patients with or without peripheral hemodynamic evidence of adenosine effect.

Adenosine↗

Influence of race on the prediction of cardiac events with stress technetium-99m sestamibi tomographic imaging in patients with stable angina pectoris.

The prognostic value of myocardial perfusion imaging in African-Americans is unknown. This study compared the prediction of cardiac events of stress technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) imaging in symptomatic Caucasian and African-American patients. Prospectively collected stress Tc-99m sestamibi tomographic imaging data from 4 medical centers, with follow-up information in 1,086 Caucasian and African-American patients, were analyzed in a core statistical laboratory. Primary events of cardiac death and nonfatal myocardial infarction and secondary events of all-cause mortality were analyzed using Kaplan-Meier survival analysis and Cox proportional-hazards multivariable model. Normal images in both African-Americans and Caucasians were associated with a low-annual cardiac event rate, whereas abnormal images were significantly associated with a higher cardiac event rate. The highest predictor of cardiac events was multivessel abnormality in both races. Use of this technique could identify patients at high risk and potentially reduce the high-cardiac event rate in African-Americans by utilizing appropriate therapies.

Aged↗

Detection of coronary vasospasm by posthyperventilation technetium-99m sestamibi single-photon emission computed tomography imaging in patients with coronary artery disease.

Forced hyperventilation is simple, safe to perform, and can be used as a provocative test for coronary vasospasm. This study assesses whether a vasospastic component of angina might be detected in patients with angiographically "nonobstructive" coronary artery disease by posthyperventilation technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) cardiac imaging. Eleven patients with angiographically nonobstructive coronary artery disease underwent Tc-99m sestamibi SPECT imaging at rest and after forced hyperventilation. Vessel diameters were measured by quantitative angiography before and after forced hyperventilation, and posthyperventilation SPECT images were compared with dipyridamole Tc-99m sestamibi stress images. Forced hyperventilation resulted in a 15% reduction in coronary artery diameter in stenotic segments (p <0.01), and a 17% reduction in adjacent nonstenotic segments (p <0.001). Myocardial uptake of Tc-99m sestamibi in segments perfused by vessels with angiographically nonobstructive stenoses was reduced by 24% following forced hyperventilation (p <0.001) compared with only 4% following dipyridamole (p <0.02). These findings suggest that posthyperventilation Tc-99m sestamibi SPECT imaging in patients with angina pectoris and nonobstructive coronary artery disease may be useful in identifying a vasospastic component of angina.

Angina Pectoris↗

Usefulness of technetium-99m sestamibi infarct size in predicting posthospital mortality following acute myocardial infarction.

In this multicenter study, 249 patients who underwent tomographic technetium-99m sestamibi infarct size measurement at hospital discharge were followed up for a median duration of 7 months. Infarct size was significantly associated with mortality (chi-square = 5.8, p = 0.02) and could stratify patients into lower and higher risk subsets: 1-year mortality 2% for infarct size < 14% versus 8% for infarct size > or = 14% of the left ventricle.

Aged↗

Estimation of shunt flow in coronary-pulmonary fistula by lung perfusion scintigraphy with technetium-99m macroaggregated albumin.

The shunt flow from the coronary artery to pulmonary arteries was evaluated in 6 patients with coronary-pulmonary fistula by lung perfusion scintigraphy with technetium-99m macroaggregated albumin. In 2 patients, whose degree of visualization of pulmonary arteries by coronary angiography was relatively high, lung perfusion scintigrams demonstrated the defects at the distal of coronary-pulmonary fistulas.

Aged↗

Comparison of electrocardiographic-gated technetium-99m sestamibi single-photon emission computed tomographic imaging and rest-redistribution thallium-201 in the prediction of myocardial viability.

Although the combined assessment of perfusion and function using rest electrocardiographic (ECG)-gated technetium-99m (Tc-99m) sestamibi single-photon emission computed tomographic (SPECT) imaging has been shown to improve sensitivity and accuracy over perfusion alone in the prediction of myocardial viability, no data are available comparing this technique with rest-redistribution thallium-201. Thirty patients with coronary artery disease and left ventricular dysfunction (ejection fraction < or = 40%) underwent rest-redistribution thallium-201 and rest ECG-gated Tc-99m sestamibi SPECT imaging before revascularization and rest ECG-gated Tc-99m sestamibi SPECT imaging at 1 or 6 weeks after revascularization. All thallium-201 and Tc-99m sestamibi images were interpreted by a consensus agreement of 3 experienced readers without knowledge of patient identity or time of imaging with Tc-99m sestamibi (before or after revascularization) using a 17-segment model. Concordance between techniques for the prediction of viability was 89% (kappa 0.556 +/- 0.109). With rest-redistribution thallium-201, sensitivity, specificity, positive predictive value, negative predictive value, and predictive accuracy were 95%, 59%, 88%, 78%, and 86%, respectively. With rest ECG-gated Tc-99m sestamibi SPECT imaging, sensitivity, specificity, positive predictive value, negative predictive value, and predictive accuracy were 96%, 55%, 87%, 80%, and 86%, respectively (p = NS vs rest-redistribution thallium-201). Although both techniques are comparable for detecting viable myocardium, rest ECG-gated Tc-99m sestamibi SPECT imaging allows direct assessment of both myocardial perfusion and ventricular function, which may be clinically useful in patients who require assessment of myocardial viability.

Coronary Disease↗

Exercise technetium-99m myocardial tomography for the risk stratification of men with medically treated unstable angina pectoris.

The prognostic value of predischarge maximal exercise stress testing with technetium-99m sestamibi (MIBI) myocardial tomography was assessed in 126 consecutive men hospitalized with a diagnosis of unstable angina pectoris who were medically stabilized. None had coronary revascularization for < or = 6 months after testing. Over a mean follow-up of 12 +/- 7 months (range 1 to 29), 35 patients (28%) had a cardiac event--nonfatal acute myocardial infarction (n = 6), cardiac death (n = 5), or rehospitalization for unstable angina (n = 24). Any type of cardiac event occurred in 12% of patients with normal MIBI scans, compared with 39% of those with an abnormal MIBI scan (p < 0.001) and 60% of those with a reversible perfusion defect (p < 0.0001). Only 2% of patients with normal scans had either a nonfatal myocardial infarction or cardiac death, compared with 14% of those with abnormal MIBI scans (p < 0.05) and 25% with a reversible defect (p < 0.001). A fixed perfusion defect was not associated with increased cardiac risk. With use of multivariable Cox proportional-hazards modeling, the only scintigraphic variable with independent predictive value was the presence of a reversible MIBI defect, with a relative risk of 3.8 (95% confidence interval 1.6 to 8.6, p < 0.05) for any cardiac event, and 19.2 (95% confidence interval 2.2 to 167.0, p < 0.05) for a nonfatal myocardial infarction or cardiac death. Cardiac event-free survival was also significantly decreased in patients with a reversible perfusion defect (p < 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Evaluation by quantitative 99m-technetium MIBI SPECT and echocardiography of myocardial perfusion and wall motion abnormalities in patients with dobutamine-induced ST-segment elevation.

ST-segment elevation during exercise testing has been attributed to myocardial ischemia and wall motion abnormalities (WMA). However, the functional significance of ST-segment elevation during dobutamine stress testing (DST) has not been evaluated in patients referred for diagnostic evaluation of myocardial ischemia. DST (up to 40 micrograms/kg/min) with simultaneous echocardiography and technetium-99m sestamibi single-photon emission computed tomography (SPECT) was performed in 229 consecutive patients with suspected myocardial ischemia who were unable to perform an adequate exercise test; 127 (55%) had a previous acute myocardial infarction (AMI). ST elevation was defined as > or = 1 mm new or additional J point elevations with a horizontal or upsloping ST segment lasting 80 ms. Reversible perfusion defects on SPECT and new or worsening WMA during stress on echocardiography were considered diagnostic of ischemia. ST elevation occurred in 40 patients (17%) during the test; 34 of them (85%) had previous AMI. All patients with ST-segment elevation had abnormal scintigrams (fixed or reversible defects, or both) and abnormal wall motion (fixed or transient defect, or both) at peak stress. In patients who had ST elevation and no previous AMI (n = 6), ischemia was detected in all by echocardiography and in 5 (83%) by SPECT. In patients with previous AMI, the prevalence of ischemia was not different with or without ST elevation (53% vs 43% by echocardiography and 53% vs 48% by SPECT, respectively). Baseline regional wall motion score in the infarct zone was higher in patients with ST elevation.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

International prospective evaluation of scintimammography with technetium-99m sestamibi: interim results.

OBJECTIVE: The purpose of this study is to evaluate the validity and reliability of scintimammography with technetium-99m (99mTc)-labeled sestamibi as an adjunct radiodiagnostic agent in the diagnosis of breast cancer. METHODS: This is a multicenter prospective cohort clinical trial that was initiated in June 1999 and will terminate May 2001. All patients with a physical or mammographic finding visiting any of the participating clinics are enrolled in the study. Patients who are younger than 18 years, pregnant, not willing to sign the consent form, or who have undergone an invasive procedure on the breast 30 days or less before scintimammography are excluded. At the time of the first interim report, 633 patients had been recruited from six Canadian centers. To date complete data have been collected for 530 patients. RESULTS: The mean (SD) age of the patients is 56 (12) years with a range between 24 and 85. There were 122 (23%) of the women in the sample who were postmenopausal and 36 (7%) who were perimenopausal. Breast density was graded as dense for 127 (24%), normal for 260 (50%), and fatty for 138 (26%). Of the 530 women in the study 156 (29%) had a palpable mass at physical examination. The mammographic results were classified as 76 (14%) breast imaging reporting and data system (BIRADS) 5, 60 (11%) BIRADS 4, 70 (13%) BIRADS 3 and the remaining BIRADS 2 or 1. The scintimammography results were positive for 118 (23%) of the patients and negative for 412 (78%). The histopathology showed malignant breast disease for 66 (12.5%) of the patients in the sample. Sensitivity and specificity of scintimammography for the detection of breast cancer was estimated 90.9% and 87.5%, respectively. A positive predictive value (PPV) of 50.8% with a negative predictive value of 98.5% and an accuracy of 87.5% were calculated. The PPV is interpreted as the posttest probability of disease given a positive test result. In this sample the pretest probability of disease would be best estimated by the prevalence of disease, which is equal to 12.5%. A positive scintimammography result would change the estimated probability to 51%, which is equivalent to a 400% change from the pretest value. Therefore a positive scintimammography result significantly increases our ability to predict the presence of malignant disease in this population. CONCLUSION: The interim results of the present study suggest that scintimammography with 99mTc-sestamibi is accurate and potentially useful as an adjunct to mammography for the detection of breast cancer.

Adult↗

Prospective comparison of technetium-99m-sestamibi/iodine-123 radionuclide scan versus high-resolution ultrasonography for the preoperative localization of abnormal parathyroid glands in patients with previously unoperated primary hyperparathyroidism.

Surgery for primary hyperparathyroidism is successful in 95% of patients, but ectopic glands and anatomic variations in location are causes of surgical failure. The radionuclide imaging agent, technetium (Tc)-99m-sestamibi, in conjunction with subtraction iodine-123 scanning, is a new method of preoperative localization of abnormal parathyroid glands. In a study approved by the Institutional Review Board, 22 patients with primary hyperparathyroidism underwent preoperative evaluation with high-resolution ultrasonography and Tc-99m-sestamibi/I-123 radionuclide scanning for attempted localization of abnormal parathyroid glands. Results of Tc-99m-sestamibi scanning and ultrasound were correlated with surgical and pathologic findings. Of 22 patients, 16 had a solitary parathyroid adenoma, 1 had a double adenoma, and 5 had diffuse parathyroid hyperplasia. The Tc-99m-sestamibi/I-123 radionuclide scan preoperatively identified a solitary adenoma in 14 of 16 patients (sensitivity: 88%). However, when the data were analyzed retrospectively along with surgical and pathologic findings, the Tc-99m-sestamibi scan correctly localized all parathyroid adenomas for a sensitivity of 100%. The one patient with a double adenoma had a localization image consistent with two enlarged glands. All patients with diffuse parathyroid hyperplasia had Tc-99m-sestamibi imaging consistent with diffuse hyperplasia, although delineation of individual enlarged glands was not possible. High-resolution ultrasound identified 11 of 16 parathyroid adenomas (sensitivity: 69%). The patient with a double adenoma had a negative ultrasound. Ultrasound was less accurate in five patients with diffuse hyperplasia: one scan was completely negative, two scans revealed only one enlarged gland, and two scans revealed two enlarged glands. The Tc-99m-sestamibi/I-123 subtraction radionuclide scan is more sensitive than high-resolution ultrasonography for the preoperative localization of abnormal parathyroid glands. Tc-99m-sestamibi/I-123 radionuclide scanning may be more useful than ultrasonography to the surgeon in the preoperative localization of abnormal parathyroid glands.

Adenoma↗

99m-Technetium sestamibi localized solitary parathyroid adenoma as an indication for limited unilateral surgical exploration.

BACKGROUND: Because of its successful localization of solitary adenomas, 99m-Technetium sestamibi (MIBI) may challenge the standard operation for primary hyperparathyroidism. METHODS: Thirty-five consecutive patients underwent preoperative MIBI localization to optimize a surgical approach. Single-site localization in 21 patients directed a limited unilateral neck exploration (UNE) with adenomectomy and ipsilateral gland biopsy. Fourteen patients who did not localize underwent bilateral neck exploration (BNE). Conversion to a bilateral operation was required in 1 UNE patient because no adenoma was found on that side. RESULTS: There were no significant differences in preoperative and postoperative serological markers between the two groups. However, the total operative time for UNE (49 +/- 21 minutes) was significantly less than for BNE (103 +/- 45 minutes; P <0.001). CONCLUSIONS: Preoperative MIBI scan-directed limited unilateral neck operation may be used reliably for primary hyperparathyroidism due to a single adenoma, and thereby reduce operative time, extent of surgical dissection, and risk.

Adenoma↗

Analysis of savings in operative time for primary hyperparathyroidism using localization with technetium 99m sestamibi scan.

BACKGROUND: The cost effectiveness of preoperative localization in cases of primary hyperpara-thyroidism has not been established. We analyzed the potential savings in operative time after localization with technetium 99m (99mTc) sestamibi scan. METHODS: Thirty-three patients had localization of a solitary adenoma with 99mTc-sestamibi. Measurement was made of the time required for adenomectomy, unilateral neck exploration (UNE), unilateral neck exploration and confirmation of one contralateral parathyroid gland (UNEC), or bilateral neck exploration (BNE). RESULTS: The total operative time in minutes was 76.4 +/- 18.8 for adenomectomy; 87.5 +/- 20.4 for UNE; 105.6 +/- 25.0 for UNEC; and 117.9 +/- 26.7 for BNE. The time difference was significant between adenomectomy versus UNE, UNEC, and BNE. There were also significant time differences between UNE versus UNEC and BNE. CONCLUSIONS: The preoperative localization of a solitary parathyroid adenoma may optimize operative time with UNE, saving approximately 30 minutes.

Adenoma↗

Technetium stannous pyrophosphate myocardial scintigrams in the recognition of myocardial infarction in patients undergoing coronary artery revascularization.

Myocardial imaging using technetium 99m stannous pyrophosphate (99mTc-PYP) has been utilized preoperatively and three to five days postoperatively to detect myocardial infarction in 48 patients undergoing aortocoronary bypass grafting, including 7 having valve replacement (5 aortic, 2 mitral) in addition to revascularization. In the total group of patients operated on there were 3 deaths (6%). Preoperatively, 26 patients had unstable angina and 10 had severe left main coronary artery disease. Eleven of the 48 (23%) were women. ECG and enzyme-proved infarctions occurred in 6 of the 48 patients (12%), but the addition of 99mTc-PYP myocardial imaging demonstrated scintigraphic evidence of infarction in 15 patients (31%), including 2 who died in the operating room. The 99mTc-PYP myocardial imaging technique, which has proved safe, simple, and relatively inexpensive in these patients, suggests that the incidence of infarction after coronary bypass operations is somewhat higher than has been previously recognized from just ECG and enzyme changes. This technique also has been of value in helping to exclude myocardial infarction in difficult clinical situations such as postoperative arrhythmias and the postpericardiotomy syndrome.

Adult↗

Can technetium 99m pyrophosphate be used to quantify myocardial injury in donor hearts?

BACKGROUND: There are no prospective methods available to quantify the myocyte injury in hearts prior to transplantation. The potential of the isotope labeled infarct marker 99m Technetium pyrophosphate (TcPPT) being used in this role was investigated. METHODS: Brain death was induced by creating an extradural space occupying lesion in young adult swine after which hemodynamic changes were monitored and myocyte injury was quantified by histochemistry. TcPPT was administered 5 hours after induction of intracranial hypertension, and after hearts were harvested myocardial uptake was measured. These latter measurements were related to the histochemical assessment of myocyte injury. RESULTS: Sham animals (n = 4) maintained cardiovascular stability and experienced minimal myocyte injury, grades 0 to 3. BD animals (n = 10) exhibited varying patterns of hemodynamic change and myocyte injury, the latter was significant in 6, graded 4 to 11, p less than 0.05. Uptake of TcPPT by BD hearts was greater than twice the 90th centile sham value in 6. The sensitivity and specificity of greater uptake indicating the presence of myocyte injury was 83.3% and 75% respectively. CONCLUSIONS: TcPPT has the potential to quantify myocardial injury induced by brain death and its potential utility merits further investigation.

Animals↗

The effect of antipsychotic medication on relative cerebral blood perfusion in schizophrenia: assessment with technetium-99m hexamethyl-propyleneamine oxime single photon emission computed tomography.

Functional neuroimaging studies in schizophrenia have often been confounded by various factors including medication status. To explore the effects of antipsychotic medications on relative regional cerebral perfusion, we scanned a group of 33 persons with schizophrenia twice, while receiving a stable dose of antipsychotic and after being off antipsychotics for 3 weeks, using technetium-99m hexamethyl-propyleneamine oxime single photon emission computed tomography (Tc-99m HMPAO-SPECT. We found that antipsychotic significantly increased the mean relative cerebral perfusion in the left basal ganglia. Additionally, patients receiving thiothixene (n = 9) had a significantly greater increase in relative cerebral perfusion in the basal ganglia than patients receiving haloperidol (n = 12). These findings indicate that antipsychotics lead to regional increases in cerebral perfusion and that antipsychotic status must be controlled for in functional neuroimaging studies. Functional neuroimaging techniques such as SPECT may be useful in furthering our understanding of the mechanism of antipsychotics.

Adult↗