Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Surgical Instruments”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Power-assisted lipoplasty (PAL): A clinical pilot study comparing PAL to traditional lipoplasty (TL).

The subject of this paper is a study designed to compare power-assisted lipoplasty (PAL) to traditional lipoplasty (TL) in 30 patients. PAL was used on one side and TL was used on the matching contralateral body area. In PAL, a cannula powered by medical-grade nitrogen (N(2)) reciprocates between 2000 and 4000 cpm with a 2-mm stroke. The device is commercially offered by MicroAire Surgical Instruments. While there was no difference in the speed of recovery or in the aesthetic quality of the result between the two sides, PAL was found considerably superior as far as ease of fat extraction.

Adult↗

Objective psychomotor skills assessment of experienced, junior, and novice laparoscopists with virtual reality.

Objective assessment of psychomotor skills in surgery is now a priority; however, this assessment is difficult to achieve because of measurement difficulties associated with the reliability and validity of assessing surgical skills in vivo and in the laboratory. In this study virtual reality (VR) was used to overcome these problems in the objective psychomotor assessment of senior, junior, and novice laparoscopists. Twelve experienced laparoscopic surgeons (performed >50 Minimal Access Surgery (MAS) procedures), 12 inexperienced laparoscopic surgeons (<10 MAS procedures), and 12 laparoscopic novices (no MAS procedures) participated in the study. Each subject completed all six tasks of the Minimally Invasive Surgical Trainer; Virtual Reality (MIST VR). In comparison to the other groups, experienced laparoscopic surgeons performed the tasks significantly (p < 0.01) faster, had a lower error rate, were more economic in their movement of surgical instruments and in the use of diathermy. As a group they also showed greater consistency in their performance. MIST VR distinguished between the three groups of laparoscopists. VR provides a useful objective assessment tool for evaluating psychomotor skills for laparoscopic surgery.

Adult↗

Arrow wounds: major stimulus in the history of surgery.

To illustrate how the high incidence of arrow wounds provided a major stimulus for the development of surgery until a century ago, we conducted a literature search. Our research shows that archaic peoples developed considerable surgical skill for extraction of arrows, including thoracotomy and trephination. A classical Hindu veda describes a variety of extraction methods, and Homer's Iliad introduces the term iatros, which means "he who extracts arrows." Hippocrates of Kos and Galen, representatives of the humoral doctrine, both shunned surgical intervention and considered purulence a drainage of materia peccans (spoiled humors). Cornelius Celsus was the first to systematically differentiate removal of arrows per extractionem and per expulsionem. Celsus recommended the spoon of Diocles, an ancient surgical instrument specially designed for extraction of arrows. Paulus of Aegina favored rapid extraction, aggressive therapy, and ligature on both sides of a vessel before extraction efforts. Paulus was the first to describe a special instrument for the removal of detached arrowheads per expulsionem (propulsorium). In medieval Europe, the standard of surgery declined drastically. The classical procedure under the dominant influence of the humoral concept was to await pus before extraction and to burn the wound with boiling oil and a branding iron. Arab authors had conserved the knowledge of Celsus and Paulus, and in Europe a renewal was achieved by Ambroise Paré, who has been called the creator of modern surgery. The incidence of arrow wounds increased once more in the American West. Joseph H. Bill, a famous U.S. Army Surgeon preoccupied with arrow wounds, favored rapid extraction and aggressive therapy, and he taught recruits not to apply traction on the shaft. The principles established by Celsus, Paulus, Paré, and Bill not only mark important landmarks in the evolution of surgery but can also serve as the basis for modern treatment of arrow wounds, which still occur, although on a small scale.

General Surgery↗

Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates.

INTRODUCTION: Stainless steel and commercially pure titanium are widely used materials in orthopedic implants. However, it is still being controversially discussed whether there are significant differences in tissue reaction and metallic release, which should result in a recommendation for preferred use in clinical practice. MATERIALS AND METHODS: A comparative study was performed using 14 stainless steel and 8 commercially pure titanium plates retrieved after a 12-month implantation period. To avoid contamination of the tissue with the elements under investigation, surgical instruments made of zirconium dioxide were used. The tissue samples were analyzed histologically and by inductively coupled plasma atomic emission spectrometry (ICP-AES) for accumulation of the metals Fe, Cr, Mo, Ni, and Ti in the local tissues. Implant corrosion was determined by the use of scanning electron microscopy (SEM). RESULTS: With grades 2 or higher in 9 implants, steel plates revealed a higher extent of corrosion in the SEM compared with titanium, where only one implant showed corrosion grade 2. Metal uptake of all measured ions (Fe, Cr, Mo, Ni) was significantly increased after stainless steel implantation, whereas titanium revealed only high concentrations for Ti. For the two implant materials, a different distribution of the accumulated metals was found by histological examination. Whereas specimens after steel implantation revealed a diffuse siderosis of connective tissue cells, those after titanium exhibited occasionally a focal siderosis due to implantation-associated bleeding. Neither titanium- nor stainless steel-loaded tissues revealed any signs of foreign-body reaction. CONCLUSION: We conclude from the increased release of toxic, allergic, and potentially carcinogenic ions adjacent to stainless steel that commercially pure Ti should be treated as the preferred material for osteosyntheses if a removal of the implant is not intended. However, neither material provoked a foreign-body reaction in the local tissues, thus cpTi cannot be recommend as the 'golden standard' for osteosynthesis material in general.

Adipose Tissue↗

Phonosurgery of the vocal folds: a classification proposal.

The Phonosurgery Committee of the European Laryngological Society (ELS) has examined the definition and technical description of phonosurgical procedures. Based on this review, the committee has proposed a working classification. The current presentation is restricted to vocal fold surgery (VFS) with phonosurgical intent. Both the pathology and the therapeutic aim define VFS: (1). vocal fold lesions that impair vibratory movements require excision (e.g., vocal fold nodule), incision and suction (e.g., Reinke's edema), dissection and/or augmentation (e.g., sulcus-vergeture), coagulation or vaporization (e.g., varicosity) and incision and stenting (e.g., glottal web); (2.vocal fold movement disorders require position and/or tension correction by augmentation (e.g., vocal fold paresis), injection (e.g., botulinum toxin for spasmodic dysphonia) and excision (e.g., dysphonia plicae ventricularis). This presentation excludes surgical instrumentation, implants or injectable materials. Being essentially surgeon-dependent, usage may vary over time and with experience.

Humans↗

The umbilicus in laparoscopic surgery.

BACKGROUND: This study examines the factors related to infection and incisional herniation after laparoscopy at the umbilicus, as compared with those at remote sites. METHODS: From a prospective database of 561 cholecystectomies, 190 inguinal hernia repairs, 71 Nissen fundoplications, and 51 ventral hernia repairs, 873 consecutive Hasson cannula sites, 748 umbilicus sites, and 125 remote sites were analyzed. RESULTS: The wound infection rate was found to be 6%: 7% at the umbilicus (9% after cholecystectomy and 2% after other operations [p < 0.05]) and 0% at remote sites (p < 0.05). Excluding cholecystectomy, the umbilical infection rate was 2%, similar to that at remote sites. The postoperative ventral hernia rate was at 0.8%, the same at the umbilicus as elsewhere. The rate was similar for gallbladder and nongallbladder operations and correlated with the postoperative wound infection rate, but not with the preexisting fascial defect rate. CONCLUSIONS: Wound infection at the umbilicus is similar to that at other sites, except after cholecystectomy. Postoperative ventral hernia at the umbilicus is similar to that at other sites and not related to preexisting fascial defects.

Adult↗

Study comparing sutures and nonpenetrating titanium clips for arteriotomy closure after embolectomy.

BACKGROUND: The vascular closure staple (VCS) clip applier system is an alternative to suture for closing arteriotomies and performing vascular anastomoses. This study was designed to evaluate the possible advantages of its use in closing arteriotomies after embolectomy. METHODS: In this study, 26 patients with upper or lower extremity embolism underwent embolectomy, and the arteriotomy was closed using either VCS clips (group A) or sutures (group B). RESULTS: The time required for arteriotomy closure with clips (11.2 +/- 2.7s) was considerably shorter than the time required with sutures (241.2 +/- 48.7s; p < 0.0001), resulting also in shorter clamp times (380.8 +/- 127.3s vs 612.7 +/- 112.6 s; p < 0.0001). No hemodynamically significant stenoses or pseudoaneurysms were detected at the arteriotomy sites in any of the patients up to 1 year after embolectomy. CONCLUSIONS: The VCS clip applier system, a quick and easy method for closing arteriotomies, is as safe as sutures in terms of narrowing of the artery and formation of pseudoaneurysm.

Aged↗

A new robotic endoscope manipulator. A preliminary trial to evaluate the performance of a voice-operated industrial robot and a human assistant in several simulated and real endoscopic operations.

We report our learning experience in simulated and real surgical tasks with a new voice-controlled robotic endoscope manipulator: an industrial robot with the tool-holder arm modified to support the optic and camera. The manipulator control-card programs have been rewritten to meet the needs of endoscopic surgeons. For this preliminary work, systems engineers with an additional monitor monitored, recorded, and compared the percentage effectiveness and precision of the responses of the robotic and human assistant to successive oral commands during the several different experimental surgical tasks. Simultaneously, to help develop this voice-commanded system for future, more precise robotic manipulation of surgical instruments, they measured the cartesian and spherical coordinates of successive positions of the optic. In unexpectedly difficult experimental conditions, the tireless robot proved more precise and effective than the demonstrably fatigable human: the steadier screen images of the robotic manipulations helped the surgeon tie knots in 7-0 sutures.

Animals↗

Endoscopic totally preperitoneal ventral hernia repair.

BACKGROUND: In order to combine the advantages of a minimal invasive approach with a retromuscular mesh implantation, we developed an endoscopic totally preperitoneal approach for the treatment of ventral hernias. METHODS: The surgical technique is described with the accent on preoperative marking of mesh surface, the retromuscular insertion of the first trocar, the extraperitoneal dissection, the reduction of the hernia sac, and the choice and insertion of the mesh. RESULTS: Fifteen patients have been operated. Complete reduction of the hernia sac could be accomplished in five. In eight, the peritoneum was incised at the hernia neck. A polypropylene mesh was used in six cases. In the others, ePTFE or a composite mesh was used. Circumferential fixation with a tacker was performed. No major complications were seen. No mesh needed to be removed. One recurrence was seen 5.5 months postoperatively with a median follow-up period of 126 days. CONCLUSIONS: This new endoscopic technique takes advantage of immediate mesh fixation by the peritoneal sac and may avoid the potential complications related to the transabdominal approach and intraabdominal position of the mesh. A further long-term evaluation is necessary.

Cellulitis↗

Comparison of adhesion formation associated with Pro-Tack (US Surgical) versus a new mesh fixation device, Salute (ONUX Medical).

BACKGROUND: We evaluated efficacy and associated adhesion formation of an innovative mesh fixation device versus the helical tack device and analyzed two implantation techniques. METHODS: Six purpose-bred female hounds were evaluated in this 90-day survival study. Six 4-cm round patches of 1-mm thick DualMesh were fixed to the abdominal wall with either 10 Pro-Tack or 10 Salute constructs in each patch. Zero to 4 additional patches were implanted with only Salute constructs. RESULTS: Adhesion severity scores were significantly higher for middle left abdominal wall sites versus lower right and upper left sites. The adhesion dissection score was higher for group T (Pro-Tack) versus group S (Salute). CONCLUSION: No significant effects occurred with adhesion extent scores, but group T developed denser adhesions. The second analysis determined that no significant differences existed relevant to secondary Salute placement, although the total score approached significance (p < 0.09). Salute equipment was easier to handle and allowed repositioning of the patch during operation.

Animals↗

Gasless laparoscopic surgery for ulcerative colitis and familial adenomatous polyposis:initial experience of 7 cases.

PURPOSE: We evaluated the data on initial experience of gasless laparoscopic surgery for patients with ulcerative colitis (UC) and familial adenomatous polyposis (FAP). PATIENTS AND METHODS: Seven patients (male/female = 3:4, median age 23, UC/FAP=5:2) underwent gasless laparoscopic total (procto) colectomy. Our basic surgical procedure involved (1) a 6- to 8-cm incision made at the beginning of the operation, (2) the wound pulled upward and/or laterally by retractors, and (3) conventional surgical instruments used through the wound; occasionally laparoscopic assistance and abdominal lifting were employed. The results were compared to those of 7 patients who had undergone conventional open surgery. RESULTS: Oral intake started earlier (p = 0.03) and C-reactive protein level on POD 4 was lower (p = 0.03) in the gasless group than in the control group. Duration of surgery, blood loss, requirement of analgesia, and morbidity rate were not significantly different between the groups. CONCLUSION: Our preliminary results suggest that gasless laparoscopic surgery for UC and FAP is feasible and can be an alternative method for minimally invasive surgery.

Adenomatous Polyposis Coli↗

Evaluation of a laparoscopic grasper with force feedback.

BACKGROUND: The clinical implementation of laparoscopic tools with haptic feedback is far from becoming a reality, partly because current tools with force feedback are not configured like conventional surgical instruments. Hence, our goal was to incorporate force sensing into existing laparoscopic tools for use in robot-assisted surgery. METHODS: We developed a laparoscopic grasper with force-feedback capability that would help surgeons to differentiate tissue stiffness based on the measured tissue deformation. RESULTS: Surgeons and nonsurgeons alike were able to qualitatively characterize different tissue samples with a high degree of accuracy. The observed force vs deformation characteristic for various tissue samples confirmed the ability of our apparatus to characterize tissues of varying stiffness. CONCLUSION: This innovative laparoscopic grasper with force-feedback capability enables accurate characterization of tissue deformation and is a promising tool for minimally invasive surgery.

Biomechanical Phenomena↗

Hand dominance and performance in a laparoscopic skills curriculum.

BACKGROUND: This study evaluated the influence of hand dominance on skill acquisition during a basic laparoscopic skills curriculum. METHODS: A total of 27 surgical residents (5 postgraduate year 3 [PGY-3] and 22 PGY-2 residents) participated in a 4-week laparoscopic skills curriculum. The residents were pre- and posttested on six laparoscopic tasks during weeks 1 and 4. During weeks 2 and 3, the residents attended a proctored practice session. The results were compared using analysis of variance (ANOVA), (with significance determined by a p value less than 0.05. RESULTS: The posttest scores were significantly higher than the pretest scores. On the pretest, lefthand-dominant (LHD) surgeons (n = 4) performed significantly better than righthand-dominant (RHD) surgeons (n = 23). In the analysis of individual task pretest scores, LHD surgeons performed significantly better on pattern cutting and vessel loop application. Posttest analysis of overall performance did not show significant differences between the RHD and LHD surgeons. CONCLUSIONS: Participation in a laparoscopic skills curriculum improved overall performance. The LHD surgeons demonstrated better initial performance, but posttest comparison showed no difference between the two groups.

Adult↗

Laparoscopic incisional hernia repair in a porcine model: what do transfixion sutures add?

BACKGROUND: The aim of this study was to evaluate the need for transfixion sutures during laparoscopic ventral hernia repair with mesh. METHODS: Incisional hernias were created in 14 Yucatan mini-pigs. Animals were randomized to undergo laparoscopic hernia repair either with spiral tacks alone (Tacks) or with tacks and 4 Prolene transfixion sutures (Sutured) using Composix E/X mesh (Davol Inc.). At 4 weeks, exploratory laparoscopy was performed to assess the repair and score adhesions. The abdominal wall was harvested for tensile strength analysis and histologic evaluation. Continuous variables were compared using a two-tailed nonpaired t-test. Results are presented as mean +/- standard deviation. RESULTS: The mean hernia size was 8.5 +/- 0.5 cm by 5.5 +/- 0.7 cm, with no difference between groups. The operative time was significantly longer ( p = 0.006) for the Sutured group (62.1 +/- 16.8 min) than for the Tacks group (32.3 +/- 7.0 min). The number of tacks per repair was equivalent between groups. At necropsy, the mesh in all cases was well incorporated, reperitonealized, and without evidence of migration. No hernias recurred. However, the Sutured group had a significantly ( p < or = 0.05) higher adhesion score (5.4 +/- 3.3) than the Tacks group (2.0 +/- 2.7). The tensile strength of the repair zone was no different between groups (Sutured 4.8 +/- 1.5 N/cm, Tacks 3.8 +/- 1.4 N/cm). On histologic examination, the ratio of inflammatory cells to fibroblasts was similar between groups (Sutured 0.2 +/- 0.6, Tacks 0.2 +/- 0.3). Only 82% of tacks in each group penetrated the fascia, and the depth of tack penetration was similar between groups (Sutured 3.7 +/- 0.3 mm, Tacks 3.9 +/- 0.4 mm). CONCLUSIONS: In a porcine model, the use of transfixion sutures was associated with longer operative times and more adhesions, without improvement in tensile strength or mesh incorporation. A human clinical trial is needed to determine the optimal method of securing abdominal wall mesh.

Abdominal Wall↗

Dual endoscopic-assisted endoluminal colostomy reversal: a feasibility study.

BACKGROUND: Emergent colostomies are associated with increased morbidity related to second closure operations. The purpose of this canine pilot study was to create a minimally invasive procedure that would reduce the time interval and morbidity involved with colostomy reversals after left colon end colostomies. METHODS: Six mongrel dogs underwent modified laparoscopic Hartmann's procedures in which the stapled end of the rectal stump was approximated to the left colon proximal to the stoma. After 1 week, they underwent an endoluminal colostomy reversal with a computer-mediated, circular stapling device and varying anvil insertion methods. Variables recorded included anvil insertion technique and feasibility, OR time, complications, and number of days to first meal and bowel movement. A contrast enema performed 1 week post colostomy reversal ruled out anastomosis leaks and stenosis. The dogs were euthanized and subjected to necropsy. RESULTS: Of four anvil insertion techniques tested, the most feasible employed a large-bore needle to perforate through the stapled end of the Hartmann pouch into the lumen of the left colon. Simultaneous endoluminal views of the rectal stump with a sigmoidoscope and the left colon lumen with an endoscope permitted a controlled and safe needle puncture. Through the needle, a guide wire was inserted to withdraw the anvil via the colostomy into place. A transanally inserted stapler was then married to the anvil under fluoroscopic guidance, thus completing the anastomosis. The colostomy was then taken down and transected at the level of the colocolostomy. Average operating time was 126 min (range 90-180), diet was tolerated within 1.5 days, and average number of days to first bowel movement was 2.5. The absence of stenosis, leaks, and inadvertent visceral injuries confirmed feasibility. CONCLUSIONS: In this canine model, a dual endoscopic-assisted colostomy reversal with a computer-mediated, circular stapling device is feasible. Using this technique, colostomy reversals can possibly be performed 1 week post-colostomy without entering the peritoneal cavity, thus reducing the number of invasive operations and subsequent morbidity required to manage emergent colon perforations.

Anastomosis, Surgical↗

A nickel-titanium memory-shape device for colonic anastomosis in laparoscopic surgery.

BACKGROUND: Minimally invasive surgery is used increasingly for colonic resection. With this procedure, the involved colon is dissected laparoscopically and exteriorized through a small incision, and the segment containing the tumor is resected. The anastomosis is performed extraperitoneally either by hand suture or with a stapler. This study was designed to evaluate the feasibility of using a memory-shape compression anastomosis clip (CAC) to perform laparoscopically assisted colonic anastomosis. The study was prompted by the authors' successful experience with the CAC in an animal model and in 10 patients with diverse colonic cancers. METHODS: The sample consisted of 10 patients who underwent laparoscopic colonic surgery at the authors' center. The anastomosis was performed with the CAC for five patients and with a stapler for five patients. To perform anastomosis with the CAC, the two edges of the resected colon are aligned. Two 5-mm incisions are made near the edges, through which the CAC, after cooling in ice water, is introduced in an open position using a special applier. In response to body temperature, the clip resumes its original (closed) position, thereby clamping the two bowel loops together. At the same time, the small scalpel incorporated in the applier makes a small incision through the clamped walls for the passage of gas and feces, and the clip is released into the intestine. The two 5-mm incisions are sutured. The clip is expelled with the stool within 5 to 7 days, creating a perfect uniform anastomosis. RESULTS: Neither group had complications, except one patient from the control group who experienced a small bowel obstruction attributable to a wound suture problem, which required laparotomy. His recovery was uneventful. CONCLUSIONS: The use of the CAC for colonic laparoscopic surgery is simple and very efficient, shortening operation time. It creates a uniform anastomosis, approximating the no-touch concept in surgery, and may prevent infection. It also is lower in cost than the stapler.

Aged↗

Vascular pedicle ligation techniques during laparoscopic colectomy. A prospective randomized trial.

BACKGROUND: A variety of devices are available for pedicle ligation during laparoscopic colectomy including vascular staplers, clips, and electrothermal bipolar vessel-sealing devices. This study assesses their speed, reliability, and cost to guide surgeons in their choice for intracorporeal pedicle ligation. METHODS: A prospective randomized study comparing laparoscopic vascular staplers and disposable clip appliers (S/C) with the LigaSure Atlas (LIG) was performed during elective right, left, and total colectomy. Cases were stratified by procedure. Failure was defined as any bleeding after proper pedicle ligation. RESULTS: The study included 48 S/C patients and 52 LIG patients with no differences in demographics, diagnosis, procedure, number of vessels ligated per procedure, or operative time. Failure occurred for 14 (9.2%) of the 152 vessels ligated in the S/C group, as compared with 5 (3%) of the 169 vessels ligated in the LIG group (p = 0.02). The median blood loss associated with device failure was 50 ml (range, 20-50 ml) in S/C group, as compared with 100 ml (range 25-800 ml) in the LIG group (p = 0.054). Major blood loss attributable to device failure and surgeon error occurred in only one LIG case. The mean cost per case of vessel ligation was significantly less in the LIG group (317 dollars +/- 0 dollars vs 400 dollars +/- 112 dollars; p < 0.001). The cost differences were greatest for total colectomy (LIG = 317 dollars +/- 0 dollars vs S/C = 565 dollars +/- 67 dollars; p = 0.002). CONCLUSION: Device failure, although more common in the S/C group, does not result in significant blood loss. The LigaSure Atlas is more cost effective during laparoscopic colectomy, especially total colectomy, and may allow the surgeon more versatility in its application.

Adult↗