Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Separation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

On-chip chiral separation based on bovine serum albumin-conjugated carbon nanotubes as stationary phase in a microchannel.

A novel method of chiral separation based on protein-stationary phase immobilized in a poly(methyl methacrylate) microfluidic chip was developed. BSA conjugated with the shortened carboxylic single-walled carbon nanotubes (SWNTs) was employed as the chiral selector. Successful separation of tryptophan enantiomers was achieved in less than 70 s with a resolution factor of 1.35 utilizing a separation length of 32 mm. This is the first example of chiral separation based on SWNTs-BSA conjugates as stationary phase immobilized in microchip channel. The stability of the stationary phase in the channel was examined by microchip electrophoresis with laser-induced fluorescence detection. Factors that influenced the chiral separation resolution were examined. Under the optimized conditions, the proposed modified chip revealed adequate repeatability concerning run-to-run. These results show that the use of SWNTs-BSA conjugates within microfluidic channels hold great promise for a variety of analytical schemes.

Carbon↗

Capillary electrochromatographic separation of proteins on a column coated with titanium dioxide nanoparticles.

A TiO2 nanoparticle (TiO2 NP)-coated open-tubular column for the capillary electrochromatographic separation of proteins is described. The surface chemistry of the TiO2 NPs on the inner wall of the fused silica was significantly affected by the running buffer. By varying of the phosphate buffer pH, only cathodic EOF was indicated. The results showed that TiO2 NPs are existed as a complexed form with the buffer ligand. Good separation of conalbumin (ConA), apo-transferrin (apoTf), ovalbumin (OVA), and BSA could be achieved with phosphate buffer (40 mM, pH 8.0) and an applied voltage of 15 kV. Five peaks of glycoisoforms of OVA were observed under these conditions. In comparison with the retention behavior of the analytes on the bare fused-silica column, the new column's high resolving power seems to be predominantly derived from the ligand exchange of the analytes with the phosphate adsorbed onto the TiO2 NPs. The method was also used to separate egg-white proteins. Both acidic and basic proteins in egg white were separated in a single run. The microheterogeneities of OVA could also be found in it. The separation efficiency for the main peak of OVA in egg white was around 10,000 plates/m.

Animals↗

Accessible proteomics space and its implications for peak capacity for zero-, one- and two-dimensional separations coupled with FT-ICR and TOF mass spectrometry.

The number and wide dynamic range of components found in biological matrixes present several challenges for global proteomics. In this perspective, we will examine the potential of zero-dimensional (0D), one-dimensional (1D), and two-dimensional (2D) separations coupled with Fourier-transform ion cyclotron resonance (FT-ICR) and time-of-flight (TOF) mass spectrometry (MS) for the analysis of complex mixtures. We describe and further develop previous reports on the space occupied by peptides, to calculate the theoretical peak capacity available to each separations-mass spectrometry method examined. Briefly, the peak capacity attainable by each of the mass analyzers was determined from the mass resolving power (RP) and the m/z space occupied by peptides considered from the mass distribution of tryptic peptides from National Center for Biotechnology Information's (NCBI's) nonredundant database. Our results indicate that reverse-phase-nanoHPLC (RP-nHPLC) separation coupled with FT-ICR MS offers an order of magnitude improvement in peak capacity over RP-nHPLC separation coupled with TOF MS. The addition of an orthogonal separation method, strong cation exchange (SCX), for 2D LC-MS demonstrates an additional 10-fold improvement in peak capacity over 1D LC-MS methods. Peak capacity calculations for 0D LC, two different 1D RP-HPLC methods, and 2D LC (with various numbers of SCX fractions) for both RP-HPLC methods coupled to FT-ICR and TOF MS are examined in detail. Peak capacity production rates, which take into account the total analysis time, are also considered for each of the methods. Furthermore, the significance of the space occupied by peptides is discussed.

Biotechnology↗

Preparative separation of a multicomponent peptide mixture by mass spectrometry.

We report on the first multiplex preparative separation by mass spectrometry of bio-organic molecules in the 200-350 Da mass range that is typical for synthetic drugs. A five-component mixture consisting of two di- and three tripeptides has been separated by mass using a specially designed mass spectrometer. The instrument for preparative separations consists of an electrospray ionization (ESI) source, ion transfer optics, an electrostatic sector, and an inhomogeneous-field magnetic mass analyzer that achieves linear mass dispersion of ion beams. Protonated peptides produced by electrospray were separated, nondestructively landed on a 16-channel array of dry collector plates, and reconstituted in solution. The preparation procedures and the instrumental conditions have been optimized to maximize the ion currents. The significant features of the special mass spectrometer are high ion currents and simultaneous separation and collection of mixture components.

Mass Spectrometry↗

Increased adult hippocampal brain-derived neurotrophic factor and normal levels of neurogenesis in maternal separation rats.

Repeated maternal separation of rat pups during the early postnatal period may affect brain-derived neurotrophic factor (BDNF) or neurons in brain areas that are compromised by chronic stress. In the present study, a highly significant increase in hippocampal BDNF protein concentration was found in adult rats that as neonates had been subjected to 180 min of daily separation compared with handled rats separated for 15 min daily. BDNF protein was unchanged in the frontal cortex and hypothalamus/paraventricular nucleus. Expression of BDNF mRNA in the CA1, CA3, or dentate gyrus of the hippocampus or in the paraventricular hypothalamic nucleus was not affected by maternal separation. All animals displayed similar behavioral patterns in a forced-swim paradigm, which did not affect BDNF protein concentration in the hippocampus or hypothalamus. Repeated administration of bromodeoxyuridine revealed equal numbers of surviving, newly generated granule cells in the dentate gyrus of adult rats from the 15 min or 180 min groups. The age-dependent decline in neurogenesis from 3 months to 7 months of age did not differ between the groups. Insofar as BDNF can stimulate neurogenesis and repair, we propose that the elevated hippocampal protein concentration found in maternally deprived rats might be a compensatory reaction to separation during the neonatal period, maintaining adult neurogenesis at levels equal to those of the handled rats.

Age Factors↗

Separation and analysis of delta 9-tetrahydrocannabinol in biological fluids by high-pressure liquid chromatography and GLC.

High-pressure liquid chromatographic (HPLC) systems were developed to separate quantitatively delta 9-tetrahydrocannabinol from heptane-extractable lipoidal and other endogenous substances in biological fluids. These substances interfered with the quantitation by flame-ionization GLC of the unmodified compound and by electron-capture GLC of the pentafluorobenzoyl derivative. Reversed-phase HPLC elution, with 47% acetonitrile in water, and normal-phase HPLC with 25% chloroform in heptane separated delta 9-tetrahydrocannabinol from 11-hydroxy-delta 9-tetrahydrocannabinol and other monohydroxylated tetrahydrocannabinols. These systems also purified stock solutions of delta 9-tetrahydrocannabinol from accompanying contaminants. The various monohydroxylated tetrahydrocannabinols were resolved from each other in the normal phase, 80% chloroform in heptane. The delta 8- and delta 9-tetrahydrocannabinols were separable in the normal phase with 5% tetrahydrofuran in hexane. The GLC analysis of pentafluorobenzoylated delta 9-tetrahydrocannabinol had a sensitivity of 1 ng/ml of plasma, with an estimated 5% standard error with the developed extraction and GLC procedures. Radiochemical analysis of the HPLC-separated fraction had a sensitivity of 0.2 ng/ml of plasma, with an estimated 2% standard error. There was no significant difference between the liquid scintillation and electron-capture GLC assays of the HPLC-separated delta 9-tetrahydrocannabinol obtained from the plasma of dogs administered the drug. Radiolabeled compounds can be added to plasma samples as internal standards to determine the recovery efficiencies of the several procedures in the analysis of unlabeled tetrahydrocannabinol.

Animals↗

Parallel separations of oligonucleotides with optically gated sample introduction on multichannel microchips.

With the release of the human genome sequence, there has been increasing attention given to other genetic analyses, including the detection of genetic variations and fast sequencing of multiple samples for pharmacogenomics studies. Rapid injections of samples in multiplexed separation channels by optically gated sample introduction are shown here for DNA separation. Serial separations of four amino acids are shown in less than four seconds on a microchip with four multiplexed channels. Five short oligonucleotides have also been rapidly separated in 2% LPA with four channels using this technique. In addition, multiple unique samples have been simultaneously separated and five-base resolution has been demonstrated.

4-Chloro-7-nitrobenzofurazan↗

Optimization of micellar liquid chromatographic separation of polycyclic aromatic hydrocarbons with the addition of second organic additive.

The micellar liquid chromatographic (MLC) separations of polycyclic aromatic hydrocarbons (PAHs) were optimized for three micellar systems, cetyltrimethylammonium chloride (CTAC), dodecyltrimethylammonium chloride (DTAC), and sodium dodecylsulfate (SDS), with 1-pentanol as the only organic additive. A difference in the separation was observed between CTAC and SDS/DTAC. Under each optimized separation conditions, CTAC-modified mobile phase provides the least desirable separation, which is attributed to its longer carbon tail (C16 vs. C12). In addition to 1-pentanol, the main organic additive, a second organic additive (3% 1-propanol) in the micelle-modified mobile phase was found to enhance the resolution of PAH chromatographic peaks. However, the extent of the enhancement varies for the different micellar systems, with the greatest resolution improvement seen for CTAC, and little effect for shorter-tail SDS and DTAC. This study shows the potential use of second organic additive (1-propanol), to the main nonpolar additive (1-pentanol), in facilitating the MLC separation of larger nonpolar compounds.

Carbon↗

Capillary electrochromatographic chiral separations with potential for pharmaceutical analysis.

The use of capillary electrochromatography as a chiral separation technique for pharmaceutical applications is reviewed. Publications of the past 10 years that provide a potential practical application in pharmaceutical analysis are considered. Method development or validation, separation strategies, and potential routine analysis by the methods/applications cited are the main subjects on which we focused our attention. The indirect chiral separation method was only used once in CEC mode. In the direct chiral separations, the use of chiral stationary phases was obviously preferred over the use of chiral mobile phases with non-chiral stationary phases. Amongst the chiral stationary phases, those based on macrocyclic antibiotics and polysaccharide selectors were the most frequently used. Monolithic stationary phases also have several applications, but not so extended as those with packed capillary electrochromatography. The considered papers not only describe the applicability of the technique for relatively large sets of chiral analytes, they also showed that various types of stationary phases can be produced in-house in a simple manner. However, to survive as a mature separation technique, considerable time and effort are still needed to solve some disadvantages currently characterizing capillary electrochromatography.

Journal Article↗

Chromatographic methods for the separation of biocompatible iron chelators from their synthetic precursors and iron chelates.

Chromatographic methods have been developed for the separation of the three novel biocompatible iron chelators pyridoxal isonicotinoyl hydrazone (PIH), salicylaldehyde isonicotinoyl hydrazone (SIH), and pyridoxal 2-chlorobenzoyl hydrazone (o-108) from their synthetic precursors and iron chelates. The chromatographic analyses were achieved using analytical columns packed with 5 microm Nucleosil 120-5 C18. For the evaluation of all chelators in the presence of the synthetic precursors, EDTA was added to the mobile phase at a concentration of 2 mM. The best separation of PIH and its synthetic precursors was achieved using a mixture of phosphate buffer (0.01 M NaH2PO4, 5 mM 1-heptanesulfonic acid sodium salt; pH 3.0) and methanol (55:45, v/v). For separation of SIH and its synthetic precursors, the mobile phase was composed of 0.01 M phosphate buffer (pH 6.0) and methanol (60:40, v/v). o-108 was analyzed employing a mixture of 0.01 M phosphate buffer (pH 7.0), methanol, and acetonitrile (60:20:20, v/v/v). These mobile phases were slightly modified to separate each chelator from its iron chelate. Furthermore, a RP-TLC method has also been developed for fast separation of all compounds. The chromatographic methods described herein could be applied in the evaluation of purity and stability of these drug candidates.

Aldehydes↗

Separation of benzene and deuterated benzenes by reversed-phase and recycle liquid chromatography using monolithic capillary columns.

An alternate pumping-recycle system utilizing a commercially available low dead-volume switching valve was developed for microcolumn LC. The recycle system had two separation columns, and the dead volume of the recycling lines was kept to a minimum by avoiding passage of the sample through the pump chamber, sample injector, and the normal path length of a conventional UV detector. The drawback of the high total back pressure caused by the second column that is placed after the detector was overcome by on-column detection, and this eliminated the need for a high pressure flow cell. The system was used for the separation of an authentic mixture of benzene, benzene-1,3,5-d3, and benzene-d6. Baseline separation was accomplished after six cycles and the calculated theoretical plate number for benzene was 230,000. It was observed that the theoretical plate number (N) increased linearly with increasing number of cycles, and the N per unit time increased with increasing inlet pressure. The separation conditions were optimized and the separation of benzene and benzene-d6 was accomplished within 75 min at 2.5 MPa inlet pressure.

Journal Article↗

GC separation of 2-substituted ethyl propionate enantiomers on permethylated and 2,6-dimethyl-3-pentyl beta- and gamma-cyclodextrin stationary phases.

In this work, the capillary gas chromatographic enantiomer separation of eight congeneric compounds with general formulae CH3-HCX-COOC2H5 (where X = Cl, Br, I, CN, OH, OC2H5, OC6H5 and NHCOCF3) on four different permethyl- and 2,6-di-O-methyl-3-O-pentyl- beta- and gamma-CD stationary phases has been studied. The separation of enantiomers was evaluated in terms of the interactions of the X substituent of studied derivatives, as well as the nature of the 3-O-alkyl group in the 2,6-di-O-methyl-3-O-alkyl-CDs and the CDs cavity size. The differences in thermodynamic data [deltaH and -deltaS] obtained for studied compounds and the selectivity of modified beta- and gamma-cyclodextrin phases in gas chromatographic separation were evaluated. deltaH values were compared with a deltaH value of an achiral standard (ethyl propionate, where X = H) in order to obtain the contribution of a particular substituent to the overall interaction energy. It was shown that the variation in the enantiomeric separation with temperature and the retention order of these compounds on a given cyclodextrin capillary column depends on the nature of the substituents bonded to stereogenic carbon atom. It was found that the temperature dependencies of selectivity factors, In a on 1/T, were both linear as well as non-linear, inter alia depending on the number of glucopyranose units of the CD derivatives. The enantiospecific thermodynamic data [delta21(deltaH)] and [-delta21(deltaS)] which characterize the chiral recognition in the separation system were used to gain more insight into the mechanistic aspects of the enantioseparations on permethylated and 2,6-di-O-methyl-3-O-pentyl-beta- and gamma-cyclodextrins.

Journal Article↗

Zone electrophoresis separation of perfluorocarboxylic acids on a chip with conductivity detection.

Perfluorinated carboxylic acids (PFCAs), amphiphiles of anthropogenic origin, are spread worldwide throughout the environment. This work deals with their zone electrophoresis (ZE) separation on a chip with coupled columns and integrated conductivity detection. Analogies with the electrophoretic behavior of PFCAs and fatty acids were employed in a search for electrolyte conditions suitable for their separation. ZE separations in the water-ethanol electrolyte systems, based on differences in the ionic mobilities of the anions of PFCAs, provided favorable resolution and detection conditions of the homologues containing up to 10 carbon atoms in the alkyl chain. Concentration limits of detection of 0.3-6.5 micromol/L were attained for PFCAs (loaded by a 900 nL volume sample injection channel of the chip) under these separation conditions. The material of which the chip was made [poly(methylmethacrylate)] restricted its use in investigations of the separations of higher PFCA homologues as it was damaged by ethanolic and/or methanolic background electrolyte solutions required in experiments with these amphiphilic compounds.

Journal Article↗

Preparative separation of underivatized amino acids for compound-specific stable isotope analysis and radiocarbon dating of hydrolyzed bone collagen.

Analysis of stable and radioactive isotopes from bone collagen provides useful information to archaeologists about the origin and age of bone artifacts. Isolation and analysis of single amino acids from the proteins can provide additional and more accurate information by removing contamination and separating a bulk isotope signal into its constituent parts. In this paper, we report a new method for the separation and isolation of underivatized amino acids from bone collagen, and their analysis by isotope ratio MS and accelerator MS. RP chromatography is used to separate the amino acids with nonpolar side chains, followed by an ion pair separation to isolate the remaining amino acids. The method produces single amino acids with little or no contamination from the separation process and allows for the measurement of accurate stable isotope ratios and pure samples for radiocarbon dating.

Amino Acids↗

Chiral separation strategy in polar organic solvent chromatography and performance comparison with normal-phase liquid and supercritical-fluid chromatography.

A strategy, including a rapid screening and several optimisation steps, for the separation of chiral molecules of pharmaceutical interest by polar organic solvent chromatography (POSC), using four polysaccharide-based stationary phases, is proposed and compared with previously reported strategies in normal-phase (NPLC) and supercritical fluid chromatography (SFC). In a first part of this paper, different examples demonstrate the effectiveness of the POSC strategy for fast method development. Optimisation is based on the use of experimental design to map the experimental domain in an efficient way. In the second part, the best screening results, obtained after performance of earlier defined chromatographic screening strategies in NPLC and SFC, are compared to those obtained in POSC. The three techniques show complementary separation results and allowed baseline separation of 23 of 25 compounds. POSC is found to be a very interesting separation mode compared to NPLC, because of the many fast (< 10 min) baseline separations obtained.

Chromatography, Liquid↗

Evaluation of a hydrazide-linked alpha1-acid glycoprotein chiral stationary phase: separation of R- and S-propranolol.

The binding and chiral separation of R- and S-propranolol was investigated on a new type of alpha1-acid glycoprotein (AGP) column. This column was prepared through the controlled and mild oxidation of AGP, followed by the immobilization of this protein to hydrazide-activated silica. The effects of temperature, pH, ionic strength, and organic modifiers on the retention and separation of R- and S-propranolol were investigated on this column. Both the association equilibrium constants and number of binding sites for R/S-propranolol on the AGP column were found to increase with temperature and affect the measured retention factors for these compounds. Regarding the other factors, a change in the organic modifier concentration was found to give the largest change in retention and separation. It was found through these studies that both coulombic and hydrophobic interactions played important roles in determining the retention of R- and S-propranolol on the AGP column. The efficiency and separation impedance of this system were also considered. Under the final optimum conditions identified in this study, it was possible to separate R- and S-propranolol with a resolution of greater than 1.38 in less than 5 min on a 4.1 mm I.D. x 5 cm column.

Buffers↗

Studies on azaspiracid biotoxins. I. Ultrafast high-resolution liquid chromatography/mass spectrometry separations using monolithic columns.

In this study, the performance of monolithic columns was evaluated for ultrafast liquid chromatography/mass spectrometry (LC/MS) analyses and for high-resolution separations of several azaspiracid biotoxin analogs. Because of their high permeability, monolithic columns offer a number of advantages over conventional packed columns; viz., very low backpressures and relatively flat van Deemter curves at high flow rates. That is, very high flow rates can be used for ultrafast analyses or, by using longer than normal columns, high-resolution separations are possible. In a series of experiments, we varied the mobile phase flow rates between 1 and 8 mL/min, and studied their impact on chromatographic parameters such as retention time, resolution, number of plates and pressure. The chromatographic run times could be reduced to ca. 30 s without a significant change in the separation efficiency. A signal intensity comparison revealed interesting differences between atmospheric-pressure chemical ionization (APCI) and electrospray ionization (ESI) in their flow-rate dependency. An explanation with respect to the behavior as of a mass-flow or a concentration-dependent device is given in the paper. Additionally, the column length was varied between 10 and 70 cm. As a result, the number of theoretical plates increased substantially. In the example shown in the report, an increase from 13 000 plates for a 10-cm column to 80 000 for a 70-cm column is demonstrated. In addition, the potential of the monolithic columns for high-resolution LC/MS separations is shown for a complex biotoxin mixture, which was separated on a 40-cm-long column.

Animals↗

High-performance liquid chromatography separation and quantitation of methylprednisolone from rat brain.

A sensitive, reliable method for the extraction, separation, and quantitation of methylprednisolone from rat brain is reported. The method can accurately quantitate methylprednisolone levels between 9.8 and 2500 ng/injection using a two-step HPLC separation and monitoring absorbance at 254 nm. A 90% extraction recovery of methylprednisolone (interday variation of 9.0% and an intraday variation of 0.0 to 7.7%) from rat cortex was obtained with a double extraction method using low toxicity solvents. These solvents are known to quantitatively extract the neutral lipids and phospholipids from brain. Combined with the ability to separate the neutral lipid and methylprednisolone fractions for further separation, and the ability to separate all phospholipid classes in the first run, this method offers great utility combined with the reliable, high extraction recovery and sensitive quantitation of methylprednisolone.

Animals↗