Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RECORDS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Electrophysiological recordings from oxytocinergic neurones during suckling in the unanaesthetized lactating rat.

A method is described for making extracellular recordings of the spontaneous activity of single hypothalamic neurones in unanaesthetized, freely moving, lactating rats using chronically implanted micro-wire electrodes. Extracellular recordings taken from individual neurones were maintained for periods of between 1 and 12 days. These records were not affected by any normal movement of the animal. As several micro-wires were implanted into each animal it was possible to make simultaneous recordings from several different hypothalamic sites in the same animal. Some recordings were identified as those from magnocellular neurones in the paraventricular nucleus on the basis of antidromic invasion after electrical stimulation of the neurohypophysis. Milk ejection in response to the prolonged sucking of ten or more pups was intermittent, and individual milk ejections recurred at intervals of 2-10 min throughout each period of nursing. The rise in intramammary pressure at milk ejection was associated with a vigorous extensor response from the pups. This was monitored by radar to provide an index of milk ejection in the unanaesthetized rat. Eleven antidromically identified neurones were recorded through 321 milk ejections. Eight of these neurones displayed a transient (2-6s) and very substantial acceleration in discharge at the time predicted for oxytocin release, i.e. 10-12s before milk ejection. The background discharge of these cells was 0.1-2.6 action potentials/s; this increased to 16-50 action potentials/s during the brief period of accelerated activity. Twenty-five neurones were studied during 365 milk ejections in rats which did not have a stimulating electrode implanted in the neurohypophysis. Thirteen of these neurones displayed a burst of high frequency discharge before each milk ejection, similar to that described for the antidromically identified neurones. Two of the non-responsive cells displayed a phasic pattern of discharge, characteristic of vasopressinergic neurone discharge recorded in anaesthetized rats. These observations of putative oxytocinergic neurones in unanaesthetized, freely moving rats are identical with those previously made on anaesthetized rats, and establish that the high frequency burst of electrical activity displayed by magnocellular neurones some 10-12s before milk ejection is responsible for oxytocin release under normal physiological circumstances.

Action Potentials↗

Use of a self-recording and supervision program to change institutional staff behavior.

The use of a self-recording and supervision program to increase interactions between direct care staff and profoundly retarded persons in a state residential facility was investigated. Following baseline, staff were provided with instructions regarding what to self-record, criteria for how many interactions to record, and a prepared card on which to make the recordings. Throughout the study, the staff supervisor monitored intermittently staff-client interactions. Observations indicated that when the staff recorded their interactions with clients in a loosely structured dayroom setting, the rate of interactions increased noticeably for each staff person. Behavioral ecology measures indicated that other staff responsibilities, such as maintaining the cleanliness of residents and the physical area, were not affected detrimentally when social interactions increased and actually showed small improvements. Additionally, small decreases in resident self-stimulatory and disruptive/aggressive behaviors occurred when the rate of social interactions from staff persons increased. Follow-up measures indicated that the rate of staff self-recording was variable, but when staff did self-record, the increased rate of staff-client interactions maintained.

Adolescent↗

Quality assessment of fetal death records in Georgia: a method for improvement.

OBJECTIVES: Although more fetal deaths than neonatal deaths occur, routinely collected fetal death data are seldom used for perinatal epidemiologic research because of data quality concerns. We developed a strategy for identifying and correcting errors in birthweight and gestational age in fetal death records. METHODS: Using data from Georgia for 1989 and 1990, we detected singleton fetal death records having improbable or missing birthweight or gestational age by comparing these values with referent values. To verify the questionable values, we contacted 100 reporting hospitals in 1992. RESULTS: In 817 of 2226 records, values were either improbable (60.1%) or missing (39.9%). We were able to contact the hospitals to verify data for 716 (88%) of these records. Verification resulted in corrections to 405 (57%) records, and 48% of unreported birthweights were obtained. CONCLUSIONS: Many errors in recorded gestational age and birthweight were identified by this method. Rather than deleting or inputting problem data for analyses, researchers should consider efforts to verify them. Efforts to improve this information should include improved reporting, strict quality assurance, and procedures for routine verification and correction of records.

Birth Weight↗

[Objective examination and diagnosis of bruxism. 1. New device for recording muscle activity and tooth contacts during sleeping at home].

The purpose of this study was to make an objective diagnosis of bruxism using a new recording system by observation during sleeping at home. The system was composed of a portable recorder for monitoring bruxism at home and an analyzing device for recalling the data later in laboratory. Muscle activity as recorded by EMG, occlusal tooth contacts were monitored by microvibration pick-up, and grinding sounds were recorded by a small microphone, simultaneously. These were printed on the one recording paper by playing back the tape. Six subjects were selected and were monitored individually for five nights with this new system at home. Records were transcribed and analyzed in the laboratory. As a result, nocturnal muscle activity, occlusal tooth contacts, and grinding sounds were recorded and analyzed efficiently with system. This new system is considered in useful for the investigation and diagnosis of bruxism in periodontal disease.

Bruxism↗

Examination of nasopharyngeal and tracheal somatosensory evoked potential recordings in dogs.

OBJECTIVE: To investigate the value of nasopharyngeal and tracheal recordings of somatosensory evoked potentials (SSEP) in anesthetized dogs. ANIMALS: 10 healthy mixed-breed dogs (5 males and 5 females). PROCEDURE: Square-ware electrical stimuli (50 microseconds duration, 4Hz) were delivered through bipolar surface electrodes to the median nerve of the right forelimb with 7 to 12 mA constant current. The SSEP were recorded with soft electrodes placed on the epipharynx and dorsal wall of the trachea, respectively. Traditional scalp and neck recordings of SSEP were also performed, using SC-inserted needle electrodes. The potentials recorded dorsally and ventrally from the neuraxis were compared to assess the application of these signals for intraoperative neurophysiologic monitoring. RESULTS: Electrical stimulation of the median nerve resulted in multiphasic potentials recorded from all 4 recording sites. Latency and phase shifts were observed between the far-field potentials placed ventrally and dorsally from the neuraxis. CONCLUSIONS AND CLINICAL RELEVANCE: Potentials recorded with nasopharyngeal and tracheal electrodes are regarded suitable for intraoperative neurophysiologic monitoring in anesthized dogs.

Animals↗

A novel miniature bite force recorder and its clinical application.

Solid state components were used to construct a miniature bite force recorder suitable for registrations in large study groups. A semiconductor was chosen as the sensory unit. The complete recording system included a power supply, the bite force recorder, a chart recorder and a millivoltmeter. Laboratory calibration tests were performed to screen the limitations of the recorder. Series of loads were applied in the range from 10 to 1000 N. Eight females and eight males, 20 to 25 years old, were asked to produce a succession of maximum bites at three second intervals for as long as possible. The bite force recorder was positioned between the first molars on the left side. The laboratory tests showed that loads in the range from 10 to 1000 N were recorded with an error less than four percent. In the clinical tests, the mean maximal bite force was 500 N ranging from 330 to 680 N. The number of maximum bites varied from 5 to 27. No statistically significant differences were observed between the sexes as regards the maximal bite force and the number of bites.

Adult↗

Cortical evoked potentials recorded from the guinea pig without averaging.

Potentials evoked by tonal pulses and recorded with a monopolar electrode on the pial surface over the auditory cortex of the guinea pig are presented. These potentials are compared with average potentials recorded in previous studies with an electrode on the dura. The potentials recorded by these two techniques have similar waveforms, peak latencies and thresholds. They appear to be generated within the same region of the cerebral cortex. As can be expected, the amplitude of the evoked potentials recorded from the pial surface is larger than that recorded from the dura. Consequently, averaging is not needed to extract the evoked potential once the dura is removed. The thresholds for the evoked cortical potential are similar to behavioral thresholds for the guinea pig at high frequencies; however, evoked potential thresholds are eleveate over behavioral thresholds at low frequencies. The removal of the dura and the direct recording of the evoked potential appears most appropriate for acute experiments. The recording of an evoked potential with dura electrodes empploying averaging procedures appears most appropriate for chronic studies.

Acoustic Stimulation↗

Long-time follow-up after UPPP for obstructive sleep apnea syndrome. Results of sleep apnea recordings and subjective evaluation 6 months and 2 years after surgery.

Fifty unselected consecutive patients with obstructive sleep apnea syndrome (OSAS) underwent uvulopalatopharyngoplasty (UPPP). The diagnosis was based on the patient's history and recording of respiration movements (Static Charge Sensitive Bed. SCSB) and oximetry, alone or combined with polysomnography. Renewed SCSB oximetry recordings were used to evaluate the success of the treatment. Six months postoperatively 40% of the patients were classified as non-responders, i.e. their oxygen desaturation indices (ODI) were reduced by less than 50% or were still above 20. The mean body mass index (BMI) was significantly higher in the non-responder group. A second recording with complete data was obtained in 45 patients after an average of 21 months. It was found that 9 patients who had been responders in the first postoperative recording had become non-responders. Only 18 of the patients with complete data could be verified as responders after 2 years. The patients who relapsed showed a significant increase in mean BMI between the first and second postoperative recordings compared to the patients who remained responders. There were no significant differences between responders and non-responders concerning age or preoperative severity of OSAS expressed as ODI, nadir SaO2 and percentage of obstructive periodic breathing. Of the non-responders, 47% in the first postoperative recording and 52% in the second reported complete recovery from excessive daytime sleepiness. This subjective improvement was not correlated to the objective results. The conclusions of this study are thus that one postoperative recording is not enough to estimate the outcome of UPPP and that statements of the patient's subjective recovery alone must not be used for this purpose.

Adult↗

Comparison of earlobe and promontorium recording sites in electrocochleography.

A compound cochlear action potential can be recorded in man from the promontorium, after perforation of the tympanic membrane. This same cochlear action potential (along with the responses of the brain stem auditory nuclei) can also be recorded by means of earlobe-vertex electrodes. Recordings were made in patients with chronic perforations of the tympanic membrane from the promontorium and simultaneously from the earlobe (-vertex) in order to see if there is a difference in response threshold. As click intensity was decreased, the responses disappeared in both recordings at about the same stimulus intensity (threshold). At near-threshold click intensities, the response seen in the promontorium recording was the compound cochlear action potential while in the earlobe vertex recording, the response often seen was seen was that from the inferior colliculus. Thus, in most cases, there is no real advantage to be gained by perforating the tympanic membrane in order to record from the promontorium since an identical response threshold can be obtained using surface electrodes.

Acoustic Stimulation↗

Improved lower esophageal sphincter manometry: application of the end-hole recording technique in vivo.

The recommendation to use a thin end-hole catheter for lower esophageal (LES) manometry has a strong theoretic background supported by previous in vitro studies. The pressure in the closed sphincter is measured, and the problem of pressure asymmetry eliminated. In this study the advantage and applicability of an end-hole catheter compared with the composite side-hole catheter for LES manometry was tested in vivo in dogs and human subjects. Pull-through manometry was performed with a continuously infused composite four-lumen catheter with one central channel and three side-hole channels enabling simultaneous end-hole and side-hole recording of LES pressure. A pull-through produced one end-hole and three side-hole pressure registrations. The end-hole recorded resting sphincter pressure was 19.7 +/- 4.5 cm H2O in 6 dogs and 9.9 +/- 6.8 cm H2O in 89 human subjects (volunteers and patients). The side holes recorded higher pressures, longer high-pressure zones, and obvious differences--asymmetry--between the three channels. The correlation between the side-hole and end-hole recordings was equally poor with regard to both pressure and length, with r values from 0.48 to 0.61. The relative difference between the end hole and side holes was most pronounced in low-pressure sphincters. In the dogs the end-hole and one side-hole channel always recorded LES pressure close to the expected 0 pressure during reflux, whereas the other two side-hole channels recorded high pressures. The present study proved the applicability of the end-hole technique for LES manometry in vivo in man. The end hole seemed to record true sphincter pressure.

Animals↗

A hybrid clinical-research depth electrode for acute and chronic in vivo microelectrode recording of human brain neurons. Technical note.

For several decades, important scientific information has been gained from in vivo microelectrode recordings of individual human cerebral cortical neurons in patients with epilepsy. The experimental methods used, however, are technically complex and require a highly skilled intraoperative team. There are also significant experimental time limitations, as well as constraints on the type of behavioral tests conducted, and the brain regions that may be safely studied. In this report, a new method is described for obtaining in vivo microelectrode recordings using a hybrid depth electrode (HDE). High-impedance research recording contacts are interspersed between low-impedance clinical electroencephalographic (EEG) contacts along the HDE shaft. The HDE has the same external physical properties as a standard clinical depth electrode (DE). Following preclinical laboratory testing, 15 HDEs were used in the evaluation of six patients with medically refractory epilepsy. High-quality EEG recordings were obtained in all cases (two acute intraoperative, four from the chronic epilepsy monitoring unit). Action potentials from individual neurons were successfully recorded during all experimental sessions; however, the chronic preparations were clearly superior. Chronic HDEs are placed using a standard stereotactic system, and the locations of recording contacts are documented on a postimplantation imaging study. The quality of the chronic research recordings was excellent over study periods ranging from 5 to 14 days. The patients rested comfortably on the ward and were able to cooperate with complex experimental instructions. Basic neuroscientists participated fully in all aspects of the chronic investigations. The use of an HDE in place of a standard clinical DE may now allow detailed physiological investigations of any brain region targeted for clinical DE implantation.

Brain↗

Enhanced stability of somatosensory evoked potentials attained in the median nerve by using temporal electrodes for intraoperative recording in patients in the semisitting position.

OBJECT: Findings published in case reports indicate that monitoring of median nerve somatosensory evoked potentials (MN-SSEPs) is unreliable in patients who undergo surgery while in the semisitting position due to the occurrence of changes in the potentials that are unrelated to neurological damage. The present study was designed to test the hypothesis that in these patients MN-SSEPs are more stable when recording electrodes are placed over the temporal region. METHODS: In 30 patients who underwent surgery in the semisitting position, MN-SSEPs were recorded intraoperatively by using electrodes placed over the temporal region as well as those placed at conventional recording sites. The authors analyzed MN-SSEP amplitudes and latencies at different recording sites and at distinct steps of the monitoring procedure. In 10 of the 30 patients a clinically significant attenuation (> 50%) of MN-SSEP amplitude was observed at conventional recording sites and this was obviously not related to neurological damage. In contrast, no significant changes were observed in MN-SSEPs recorded from electrodes located over the temporal region. CONCLUSIONS: In patients who undergo surgery in the semisitting position, the use of additional recording electrodes placed over the temporal region makes intraoperative MN-SSEP monitoring less prone to false-positive alarms and thus enhances the reliability of intraoperative MN-SSEP monitoring.

Adolescent↗

[Somatosensory evoked potentials during surgery of scoliosis: significance of epidural recording].

PURPOSE OF THE STUDY: To evaluate the usefulness of the epidural recording in scoliosis surgery in children or young adults. MATERIAL AND METHOD: We used somatosensory-evoked potentials in 60 children or young adults in surgical treatment of scoliosis. Somatosensory-evoked potentials were elicited and recorded using a standard method recording of cortical P40 and subcortical P27, simultaneously with the monitoring of spinal cord function using epidural electrode to record the ascending somatosensory volley (by tibial nerve stimulation) at a high thoracic level. RESULTS: The use of subcortical and epidural recording sites for the somatosensory-evoked potentials indicated that a reliable response could be obtained in 96 p. 100 of the patients. Cortical somatosensory-evoked demonstrated a 48 p. 100 false positive rate. DISCUSSION: Epidural recording in scoliosis surgery is safe and reliable. Combined subcortical and epidural recordings are especially useful in patients with neuromuscular scoliosis or with cerebral palsy that may not have reliable cortical potentials.

Adolescent↗

Analysis of bladder related nerve cuff electrode recordings from preganglionic pelvic nerve and sacral roots in pigs.

PURPOSE: Electrical stimulation of appropriate lower urinary tract (LUT) nerves may be used in bladder dysfunction to achieve continence and abolish hyper-reflexic detrusor contractions. It can also be used for consequent emptying of the bladder. To control the time course of the described functional phases, knowledge of bladder sensory information is needed. We investigated if the latter could be extracted from the LUT nerve activity. MATERIALS AND METHODS: In acute experiments using 10 pigs, tripolar cuff electrodes were placed unilaterally around the pelvic nerve and the S3 and S2 roots. The cuff electrode signals, filling rate and the bladder and rectal pressures were recorded during slow and fast bladder fillings/emptyings. RESULTS: Two pigs were excluded from the analysis because of no observed changes in the nerve signals in one animal, and because of electrical noise problems in the other animal. Fast bladder pressure increases resulted in a sudden pelvic nerve signal rise in 6 out of 7 pigs (3 out of 6 for the S3 nerve signal). Slow bladder pressure increase was reflected in the recorded nerve activity only in 3 out of 8 and in 3 out of 7 pigs for the pelvic and S3 cuff signals respectively. In 2 animals small spontaneous bladder contractions were clearly reflected in the pelvic nerve signal (contractions were observed only in 3 pigs). Except in one pig, there were no slow/fast bladder filling responses recorded in the S2 roots. It is shown that the recorded responses were afferent. CONCLUSIONS: Cuff electrodes can be used to record bladder afferent information from the pelvic nerve and the sacral root S3 in pig. Pelvic nerve recordings were more selective than the sacral root recordings. Nerve activity increases were more distinct and repeatable during rapid bladder pressure changes and small spontaneous bladder contractions than during slow bladder fillings.

Action Potentials↗

[Comparison of nerve conduction studies between conventional and lumbrical/interossei recording methods in diabetics].

Median nerve conduction studies were performed by conventional and lumbrical/interossei recording methods. The former is composed of recordings of compound muscle action potential from abductor pollicis brevis (APB) and sensory nerve action potential from second digit (D) after wrist stimulation. In the latter the recording electrode was placed lateral to the midpoint of the 3rd metacarpal bone, and recorded compound muscle action potential from the 2nd lumbrical (2 L) and sensory nerve action potential from the digital nerve (N) after wrist stimulation. Subjects were 57 healthy individuals and 97 patients with diabetes mellitus. Particularly in diabetic patients values of coefficient of correlation between each measurement were high enough; i.e., r = 0.91 between latencies to 2 L and APB, r = 0.55 between amplitudes of 2 L and APB, r = 0.86 between amplitudes of N and D. Corresponding measurements by conventional method and lumbrical/interossei method were identical in the values of coefficient of correlation between measurements. The characteristics of lumbrical/interossei method are to be able to record compound muscle action potentials and nerve action potential from the same electrode. In this study values obtained by lumbrical/interossei method showed identical correlation between measurements to the corresponding ones by conventional method. In conclusion recordings of APB and D by conventional method can be replaced with the recordings of 2 L and N by lumbrical/interossei method in the evaluation of diabetic neuropathies.

Action Potentials↗

[An automated electronic anesthesia record and automated urine output measurement].

We can now collect many parameters (NIBP, HR, ABP, SpO2, EtCO2, CCO, etc) from an anesthesia monitor in an automated electronic anesthesia record system. The function of automated urine output measurement has been added to an automated electronic anesthesia record system. A digital weight meter connected with a personal computer by RS-232 C is used to measure the weight of urine. We convert the weight to the volume hypothesizing that the density of urine is 1 g.ml-1. Physiologic parameters are recorded every 10 seconds from an anesthesia monitor and we can set the period of automated urine output measurement we like. We must enter the initial and final urine output but the intraoperative urine output is collected automatically to an automated electronic anesthesia record and visualized in urine bar graph. The total volume of urine is calculated. Computerized urine output measurement can record data more frequently, for example, every 10 minute. At the end of the operation, intraoperative data are sent to a host computer and the anesthesia record is printed. Combining the automated urine output measurement with an automated electronic anesthesia record system is useful in anesthesia practice of a long operation.

Anesthesia↗

[Frequency and detection rate of silent myocardial ischemia by Holter monitoring in patients with stable coronary insufficiency under treatment. Study of 95,725 recorded hours].

AIM OF THE STUDY: To determine in standard living conditions the circadian variation of the symptomatic and silent electrocardiographic ischaemia in patients with chronic stable coronary insufficiency. To evaluate the influence of the past history of the patients on the circadian variations of the symptomatic and silent ischaemic events. METHODS: The patients included in the study presented with stable angina pectoris and have undergone a 96 hours Ambulatory ECG (AECG) monitoring with a low-weight and compact material which did not modify their daily activities (R-test). The system records the trace that the patient has initiated it himself following the onset of symptoms and makes possible to distinguish between silent and symptomatic ischaemia. The same experienced cardiologist validated all the AECG records. RESULTS: 1,022 patients aged 64.6 +/- 11.0 years suffering of coronary insufficiency from 5.8 +/- 6.0 years have undergone an electrocardiographic record by an R-test for a total duration of 95,725 hours. Of the 1,022 records, 3,258 ischaemic events have been validated: 295 (9.1%) were symptomatic and 2,963 (90.9%) were silent which correspond to a ratio of 1 versus 9 while this ratio is usually described as 1 versus 4. By 26.5% (n = 271) of the patients, ischaemia have been detected and among them more than a half (54.6%, n = 148) were presenting only silent ischaemia. Of these patients who present silent ischaemia, it was recorded during the first 24 hours by only 63.7% of them which is the usual duration of an ambulatory ECG monitoring. This percentage increases to 83.1% after 48 hours and to 94.1% after 72 hours. CONCLUSION: By more than one third (36.3%) of the patients with stable coronary insufficiency, an ambulatory ECG monitoring recorded during only 24 hours is insufficient to detect a silent ischaemia which will happen later. A record duration of 48 hours reduces this risk to 20% of the patients and of 72 hours to less than 5%.

Activities of Daily Living↗

Intra-individual variability in nighttime urine production and functional bladder capacity estimated by home recordings in patients with nocturnal enuresis.

PURPOSE: We evaluated the intra-individual variability and reproducibility of nighttime urine production on wet nights and functional bladder capacity estimated by long-term home recordings of monosymptomatic nocturnal enuresis. In particular, the intention was to evaluate the validity of 1 versus 2 weeks of recording when estimating urine volume on wet nights and 1 versus 2 weekends of recording when estimating functional bladder capacity. MATERIALS AND METHODS: We analyzed 120, 2-week home recordings of nighttime urine volume from patients with monosymptomatic nocturnal enuresis 6 to 16 years old (mean age 9.1) with at least 3 wet nights per week. Most patients were nonresponders or partial responders to desmopressin. Nighttime urine volume was estimated by weighing diapers before and after sleep, and measuring morning urine volume. Of the home recordings 62 included frequency volume charts for 2 weekends, which were evaluated for functional bladder capacity defined as the largest voided volume observed. RESULTS: No significant overall week-to-week differences were observed in average urine volume on wet nights and functional bladder capacity. There was a large intra-individual variability in all measured variables, which was most pronounced for functional bladder capacity and least pronounced for urine volume on wet nights. With regard to repeatability, the limits of agreement of urine volume on wet nights were -32% and 36% (95% confidence interval) as opposed to -54% and 48% for functional bladder capacity. CONCLUSIONS: In this study intra-individual week-to-week estimates of average urine volume on wet nights demonstrated acceptable variability and repeatability in contrast to functional bladder capacity. A reliable estimate of urine volume on wet nights could be obtained by 7 nights of home recording, whereas 4 days of daytime recording were necessary when estimating functional bladder capacity. Similar studies of patients who respond to desmopressin are needed.

Adolescent↗