Hemolytic effect of deformed intra-arterial stents and stent grafts in vitro.

Our objective was to evaluate the hemolytic effect of stents and stent grafts in an in vitro flow model. The model consisted of silicone tubings. Pulsatile flow was delivered at 1170 ml/min. Diluted packed erythrocytes were used (hematocrit of 33%). The Palmaz, MegaLink stents or Passager, Hemobahn stent grafts were placed in the middle portion of the model; control experiments contained no implant ( n=10 each). Concentric stenosis of the implant was achieved by constricting the implant to 25, 50, or 70% (area, n=10 each). Samples were drawn at minute 1, 2, 4, 6, 8, 10, 15, and every 10 min up to 1 h. Hemolytic parameters were evaluated. All implants produced hemolysis, increasing in the course of time. Without deformation (0%) the Hemobahn stent causes less hemolysis compared with the other prostheses. At 25% no significant difference could be shown between all devices. At 50% constriction the Palmaz stent caused more hemolysis than the other grafts, and at 70% stenosis the Palmaz and Hemobahn caused more hemolysis than Passager or Megalink. A hemolytic effect was evaluable, probably due to mechanical stress and sheer forces, induced by turbulences in the proximity of the deformed stent. The stent grafts did not perform better than the stents. Differences in the design of a prosthesis and in the degree of stent deformation seem to have an influence on the hemolysis caused.

Blood Vessel Prosthesis↗

Left ventricular pseudoaneurysm and rupture after limited myocardial infarction.

A 50-year-old man had a large lateral left ventricular wall pseudoaneurysm with rupture after a limited myocardial infarction. This was diagnosed by the combination of flow in and out of the aneurysm and pulsatile flow in the pericardial cavity using color flow and continuous wave Doppler ultrasound. This report describes the case management, the use of echocardiography in this setting, and the implications of pseudoaneurysm formation.

Aneurysm, False↗

Free emboli formation in the wake of bi-leaflet mechanical heart valves and the effects of implantation techniques.

The high incidence of thromboembolic complications of mechanical heart valves (MHV), primarily due to platelet activation by contact with foreign surfaces and by non-physiological flow patterns past the valve, still limits their success as permanent implants. The latter include elevated shear and turbulent stresses and shed vortices formed in the wake of the valve's leaflets during the deceleration phase, potentially entrapping activated and aggregated platelets. It is hypothesized that these flow patterns induce the formation of free emboli which are the source of cerebrovascular microemboli associated with MHV. Implicit to this hypothesis is that free emboli formation will be affected by the implantation technique employed and the valve orientation, as those will alter the flow characteristics past the valve and the interaction of the platelets with the flow. In this study, numerical simulations of turbulent pulsatile flow past a St. Jude Medical bi-leaflet MHV were conducted. Platelet shear histories were calculated along pertinent turbulent platelet trajectories, and the effect of a misaligned valve on platelet activation was quantified and compared to that of an aligned valve. It demonstrated that the combination of a tilted valve and subannularly sutured pledgets had an explicit detrimental effect on platelet activation, with the following entrapment of the platelets within the shed vortices of the wake leading to a significant increase of the thromboembolic potential of the valve. This numerical model depicted a viable course for free emboli formation, and indicated how the implantation technique may enhance the risk of cardioembolism.

Aortic Valve↗

Duplex scan findings in patients with spontaneous cervical artery dissections.

AIM: to report duplex scan findings in patients with spontaneous internal carotid artery (ICA) or vertebral artery (VA) dissection. MATERIAL AND METHODS: the records of 24 patients (13 males and 11 females, median age 48 years [range 25-68 years]) with spontaneous extracranial ICA dissection (n=20) or VA dissection (n=4), identified between January 1995 and December 1999, were retrospectively analysed. RESULTS: four different abnormal flow patterns were observed in patients with ICA dissection: (a) absence of flow (15%), (b) staccato flow (50%), (c) reduced flow velocity (25%) and, (d) stenotic flow (10%). B-mode ultrasound showed a homogenous echolucent lesion in eight patients and a double lumen in two. Staccato flow along the entire ICA was observed in only four patients without verified dissection during the study period. In the four patients with VA dissection, duplex scanning demonstrated staccato flow in three and reversed low-amplitude pulsatile flow in one. CONCLUSION: duplex scanning is an important noninvasive diagnostic modality in patients with cervical artery dissection. Staccato flow along the extracranial ICA strongly indicates the presence of spontaneous ICA dissection.

Adult↗

[Emergency endovascular treatment of acute aortic diseases].

PURPOSE: To investigate the safety and efficacy of emergency treatment of acute aortic diseases with endovascular stent grafts. METHODS: In 11 patients (median age 55 years, range 18 - 85) with acute complications of descending aortic diseases endovascular emergency treatment was performed: traumatic aortic rupture (n = 4), penetrating ulcer with aortobronchial fistula or hematothorax (n = 4), acute type B dissection (n = 2, one with penetration, one with subacute mesenteric ischemia), and symptomatic aneurysm of the thoracic aorta (n = 1) with pain and diameter progression. 15 stent grafts were implanted (Talent n = 11, Vanguard/Stentor n = 4). Stent extension was necessary in 4 cases. In 2 cases graft extension was done during the first procedure (due to distal migration and due to the total length of the aortic aneurysm). In 2 cases graft extension was performed 5 days (due to a new aortic ulcer at the proximal stent struts) and 5 months after the initial procedure (recurrent aortobronchial fistula due to aneurysm progression). 14 of 15 implantations required general anesthesia, one symptomatic thoracic aneurysm was performed in local anesthesia and sedation. RESULTS: 14 of 15 graft procedures were performed using the femoral or iliac approach. One procedure required aortofemoral bypass grafting due to extensive arteriosclerotic stenosis and the stent graft was inserted via the bypass graft. The orifice of the subclavian artery was crossed with bare stent struts in 4 cases without neurological complications. Median follow-up is 27 months (range 6 to 72 months). In traumatic aortic ruptures, immediate sealing of bleeding was achieved and follow-up is inconspicuous at a maximum of 72 months. In cases of aortobronchial fistulas, follow-up is satisfactory (maximum 72 months) despite the necessity for reintervention and graft extension. In one acute type B dissection retrograde dissection of the aortic arch occurred during stent release with stable disease during follow-up without neurological complications. In one type B dissection with mesenteric ischemia the mesenteric blood flow was restored. A second look operation confirmed pulsatile flow in the mesenteric trunk but a total necrosis of the small intestine and the patient consequently died. CONCLUSION: Endovascular treatment is safe and effective for emergency treatment of life-threatening complications in selected acute aortic syndromes. Mid-term results are encouraging, however, regular follow-up is mandatory to recognize late complications of the stent graft.

Acute Disease↗

An assessment of three portable peak flow meters.

Peak flow has become widely used as in independent measure of lung function, particularly in asthma, because it can be quickly and easily determined by simple portable instrumentation. Three relatively inexpensive devices, the Armstrong mini-Wright peak flow meter, Vitalograph pulmonary monitor, and HealthScan peak flow meter, were tested for accuracy and reproducibility. Five units of each type were individually connected in series to a pneumotachograph, and 20 measurements (five in each of four flow ranges) were made on each unit at pulsatile flows ranging from 120 to 480 Lpm. The mean percentage of discrepancy (D%) for each instrument of a particular model was calculated at each flow range, and these subsequently averaged to give an inter-instrument percentage of discrepancy at each flow for each model. Intra-instrument variability was also assessed as the mean percentage of discrepancy for all flow rates for each individual instrument. While only the Armstrong mini-wright peak flow meter meets flow range criteria established by the American Thoracic Society and American College of Chest Physicians for flow devices, only the HealthScan-Organon peak flow meter meets the established criteria for accuracy and reproducibility.

Peak Expiratory Flow Rate↗

Measurement of volume flow with time domain and M-mode imaging: in vitro and in vivo validation studies.

Color velocity imaging quantification is a commercially available technique that estimates volume flow within vessels by combining velocity data, acquired by time domain correlation, with vessel diameter measurements obtained by M-mode imaging. By integrating the velocity profile over time, quantitative volume flow calculations may be made. To investigate the accuracy of this system, we used two flow phantoms over a range of steady and pulsatile flows for in vitro evaluation, and the common carotid artery of 10 women on five consecutive occasions was insonated for in vivo assessment. In flow phantom studies, accuracy was within 8% for flows above 200 ml/min, but decreased at lower flows depending on the depth, beam-vessel angle used, and steering of the beam. At angles greater than 70 degrees, velocity errors made quantitative measurement of flow unreliable, whereas at angles less than 30 degrees, the increased error in calculating vessel diameter led to large errors of area estimation, and hence made flow measurements unreliable. For the in vivo studies on the carotid artery the intraoperator repeatability values for the three operators were 9.92% (A), 13.74% (B), and 13.24% (C). The interoperator repeatability for the group was 15.30%. This study suggests that the color velocity imaging quantification technique is an accurate and reproducible method of assessing volume flow in vessels. However, in our experience, obtaining volume flow data is more time consuming and operator dependent than traditional Doppler techniques. The color velocity imaging quantification system may be of use in monitoring conditions in which changes in volume flow in a vessel or to an organ is an important part of the disease process.

Blood Flow Velocity↗

Sonographic and colour doppler morphology in carcinoma gallbladder.

Conventional radiography has limitations in accurate diagnosis of gallbladder cancer (GBC). Ultrasonography (USG) allows correct diagnosis in 70-80% advanced and 23% early GBC. Present study was initiated to identify morphology and flow characteristics in GBC using conventional USG and Colour Doppler USG (CD-USG). In 100 patients, USG assessed morphology of mass lesion/wall thickening together with associated features. Of these, 60 cases were studied using CD-USG for intralesional/perilesional vascularity, peak systolic flow velocity (V max), resistive index (RI) and pulsatility index (PI). USG identified GB with mass lesion in 44% cases (Group-I) and only mass in GB fossa in 56% cases (Group-II). Findings identified calculi (73%), liver infiltration (74%), intrahepatic ductal dilatation (IHDD) (52%), lymphadenopathy (19%) and ascites (5%). CD-USG revealed vascularity, mainly pulsatile flow, in 78.3% cases (in 91.3% Group-I cases). Mean Vmax was 0.3037 m/sec (0.109 - 0.646 m/sec.), mean RI was 0.6621 (0.526 - 1.000) and PI was 1.282 (0.772 -2.140), Mean Vmax and PI were higher in Group-I compared to Group-II. Presence of calculus in 73% cases suggests a high association between calculus and malignancy. As flow signals were seen in 78% of all cases and 91.3% Group-I cases undergoing CD-USG, USG and CD-USG together can improve pickup rate of GBC.

Adenocarcinoma↗

[Non invasive measurement of the cerebral blood flow in infants with hydrocephalus].

The present study was undertaken to verify by a non invasive Doppler technique the effect of ventricular dilatation on cerebral blood flow in infants with hydrocephalus. The measurement of pulsatile flow in cerebral arteries is also a valuable parameter for determination of optimal timing of corrective intervention.

Cerebrovascular Circulation↗

[Comparative study of mechanical heart valves for implantation in mitral position].

For hydrodynamic comparison of mechanical heart valves, three tilting disc valves (Björk-Shiley SD, Björk-Shiley CCD, Björk-Shiley Monostrut) and two bileaflet valves (St. Jude Medical, Duromedics) with annulus diameter dA = 31 mm were perfused in a mock circulation in mitral position. Flow, pressure, and orifice area were measured during pulsatile flow. Insufficiency, maximal orifice area, mean orifice area, performance index and efficiency index were calculated. The tilting disc valves show distinctly lower orifice areas than the bileaflet valves. The mean value of maximal orifice area Amax of the Björk-Shiley prostheses varies between 227.82 +/- 7.77 mm2 and 243.21 +/- 6.21 mm2. The mean value of Amax of the Duromedics prosthesis is 295.45 +/- 7.76 mm2 and that of the St. Jude Medical prosthesis is 477.43 +/- 11.32 mm2. The calculated mean orifice areas A of the bileaflet valves are also higher than those of the tilting disc valves. The mean values of A are: Björk-Shiley SD: 183.55 +/- 10.03 mm2; Björk-Shiley CCD: 206.30 +/- 8.62 mm2; Björk-Shiley Monostrut: 210.12 +/- 4.74 mm2; St. Jude Medical: 398.69 +/- 19.55 mm2; Duromedics: 262.90 +/- 6.84 mm2. The performance index PI is qualitatively identical with the values of the mean orifice area A because in this study only heart valves of the same size were investigated. For calculation of insufficiency I the entire reflux volume VR including closing volume VS and leakage volume VL was used, thus, insufficiency was also determined in intact prostheses. The values of insufficiency of the mechanical valves investigated are higher for the bileaflet valves than for the tilting disc valves.(ABSTRACT TRUNCATED AT 250 WORDS)

Bioprosthesis↗

Pulsatile ocular blood flow measurements in healthy eyes: reproducibility and reference values.

PURPOSE: To determine the reproducibility and the normal reference range of pulsatile ocular blood flow (POBF) values in healthy subjects using the Ocular Blood Flow Tonograph (OBF Laboratories, UK Ltd., Wiltshire, England). METHOD: Pulsatile ocular blood flow was measured in one eye of each of 83 patients. Coefficient of reliability was determined by calculation of intraclass correlation coefficient via one-way analysis of variance. Mean difference between measurements was calculated for bias and first exposure effects. Pulsatile ocular blood flow from 163 healthy individuals were analyzed to determine the distribution, mean, standard deviation (SD), range, and the 5th and 95th percentile values. The influence of age, blood pressure, pulse rate, and intraocular pressure on pulsatile ocular blood flow was determined by regression analysis. RESULTS: Reliability coefficient for pulsatile ocular blood flow values ranging from 290 microliters/min to 2,196 microliters/min was 0.92. Variation in bias and first exposure effect were not significant. Pulsatile ocular blood flow values were normally distributed. Mean values were 669.90 +/- 233.0 microliters/min in men and 841.90 +/- 254.6 microliters/min in women. Fifth and ninety-fifth percentile values were 364.75 microliters/min and 1,266.10 microliters/min in men and 397.18 microliters/min and 1,346.10 microliters/min in women. Pulsatile ocular blood flow was significantly influenced by pulse rate. CONCLUSION: This study confirms the reliability of the Ocular Blood Flow Tonograph in repeated measurements of POBF within individuals over short time intervals. The high interindividual variation in POBF may invalidate comparison of POBF between individuals, and the wide range of normal values may limit the value of using a low POBF as a possible indicator of disease.

Adult↗

The influence of plasma glucose upon pulsatile ocular blood flow in subjects with type II diabetes mellitus.

AIMS/HYPOTHESIS: This study investigated the influence of plasma glucose upon pulsatile ocular blood flow in subjects with Type II (non-insulin-dependent) diabetes mellitus. METHODS: A total of 19 subjects with Type II diabetes and 8 normal control subjects undertook a meal tolerance test after an overnight fast. The pulsatile ocular blood flow, using the Ocular Blood Flow Tonometer, and plasma glucose concentrations were taken at times 0 min, 90 min and 240 min. Blood pressure and glycated haemoglobin concentrations, in the subjects with diabetes, were also measured at time 0 min. Pulsatile ocular blood flow and plasma glucose were also measured at times 0 and 90 min in 5 subjects with Type II diabetes mellitus who remained fasting. RESULTS: It was found that the subjects with diabetes who undertook the meal tolerance test showed a significant increase in both plasma glucose concentrations and pulsatile ocular blood flow from time 0-90 min, followed by a decrease from 90 min to the end of the session at 240 min. (p < 0.001 in each case). Regression analysis showed a significant correlation between the change in pulsatile ocular blood flow and the change in plasma glucose concentration (r = 0.671,p = 0.001). Control subjects showed no significant change in either plasma glucose or pulsatile ocular blood flow during the meal tolerance test. Subjects with diabetes mellitus who remained fasting also showed no significant change in pulsatile ocular blood flow or plasma glucose concentrations. No correlation was found between glycated haemoglobin concentrations or blood pressure and pulsatile ocular blood flow. CONCLUSION/INTERPRETATION: Pulsatile ocular blood flow is influenced by changes in plasma glucose concentrations in Type II diabetes mellitus, indicating that uncontrolled hyperglycaemia might result in a higher pulsatile ocular blood flow than might otherwise be expected.

Aged↗

Role of calcium-sensitive K(+) channels and nitric oxide in in vivo coronary vasodilation from enhanced perfusion pulsatility.

BACKGROUND: In vitro studies support K(+)(Ca) channel-induced smooth muscle hyperpolarization as underlying acetylcholine-mediated (or bradykinin-mediated) vasodilation that persists despite combined nitric oxide (NO) and PGI(2) inhibition. We tested the hypothesis that these channels are activated by enhanced pulsatile perfusion in vivo and contribute substantially to vasodilation from this stimulus. METHODS AND RESULTS: The canine left descending coronary artery was perfused with whole blood at constant mean pressure, and physiological flow pulsatility was set at 40 or 100 mm Hg by computer servo-pump. Cyclooxygenase was inhibited by indomethacin. Mean flow increased +18+/-2% (P:<0.0001) with enhanced pulsatility. This response declined approximately 50% by blocking NO synthase (L-NMMA) or K(+)(Ca) [charybdotoxin (CbTX)+apamin (AP)]. Combining both inhibitors virtually eliminated the flow rise. Inhibiting either or both pathways minimally altered basal coronary flow, whereas agonist-stimulated flow was blocked. Bradykinin-induced dilation declined more with CbTX+AP than with L-NMMA (-66% versus -46%, P:=0.03) and was fully blocked by their combination. In contrast, acetylcholine-induced dilation was more blunted by L-NMMA than by CbTX+AP (-71% versus -44%, P:<0.002) and was not fully prevented by the combination. Substituting iberiotoxin (IbTX) for CbTX greatly diminished inhibition of pulse pressure and agonist flow responses (with or without NOS inhibition). Furthermore, blockade by IbTX+AP was identical to that by AP alone, supporting a minimal role of IbTX-sensitive large-conductance K(+)(Ca) channels. CONCLUSIONS: K(+)(Ca) activation and NO comodulate in vivo pulsatility-stimulated coronary flow, supporting an important role of a hyperpolarization pathway in enhanced mechanovascular signaling. Small- and intermediate-conductance K(+)(Ca) channels are the dominant species involved in modulating both pulse pressure- and bradykinin-induced in vivo coronary dilation.

Acetylcholine↗

Computer-controlled flow simulator for MR flow studies.

A novel computer-controlled flow simulator for use in magnetic resonance (MR) flow experiments was evaluated. The accuracy in constant-flow mode was better than 1%. The accuracy in pulsatile-flow mode was found to be dependent on the interconnecting tubing. The short-term and long-term reproducibilities of pulsatile waveforms were less than or equal to 0.4 mL/sec (1 standard deviation). Increased response times due to the lengths of tubing required in MR flow experiments were surmounted by using a modified tubing configuration and precompensated waveforms. Piston reversal was found not to cause major difficulties in MR flow experiments.

Blood Circulation↗

Microcirculation of the bulbar conjunctiva in the goat implanted with a total artificial heart: effects of pulsatile and nonpulsatile flow.

A new system to observe the microcirculation on the bulbar conjunctiva was developed using a digital high definition microscope to investigate the influence of the flow patterns on the microcirculation in a goat with a total artificial heart (TAH). The undulation pump TAH was implanted into the goat. When the whole body condition became stable, the flow pattern was modulated between the pulsatile and the nonpulsatile mode, and the changes in the microcirculation were observed. When the flow pattern was changed from pulsatile to nonpulsatile mode, the erythrocyte velocity in capillaries dropped from 526+/-83 to 132+/-41 microm/s and remained at a low level. The number of perfused capillaries decreased as well. Then the nonpulsatile flow mode was maintained for 20 minutes. After the flow pattern was returned to the pulsatile mode again, the erythrocyte velocity recovered to the initial level (433+/-71 microm/s). In many cases, the flow of the nonperfused capillaries in the nonpulsatile mode recovered to the initial level after the flow pattern was changed to the pulsatile mode again. The perfused capillary density in the nonpulsatile mode (19.7+/-4.1 number of capillaries/mm) was significantly lower than that in the pulsatile mode (34.7+/-6.3 number of capillaries/mm). It is thought that the basal and flow stimulated endothelium derived nitric oxide release in the microvessels decreased because of the disappearance of pulsatility and that the nitric oxide induced the constriction of arterioles after the flow pattern was changed to the nonpulsatile mode. At the same time, the baroceptors might sense the decrease in the arterial peak pressure or dp/dt, and the sympathetic nerve increases activities and induce the constriction of arterioles. Then, the erythrocyte velocity in capillaries would decrease. Because of the flow pattern further in the chronic phase, it is important to follow the change in the microcirculation.

Animals↗

The reversibility of reduced cortical vein compliance in normal-pressure hydrocephalus following shunt insertion.

Superficial cortical venous compression secondary to alterations in craniospinal compliance is implicated in the pathogenesis of normal pressure hydrocephalus (NPH). A reduction in the pulsation in the outflow of the cortical veins would be expected to occur following compression of these veins and this has been shown in NPH. If cortical vein compression is a causative factor in NPH, it would be expected that cortical vein compliance as measured by pulsatility would be significantly altered by a curative procedure i.e. shunt tube insertion. My purpose is to compare the blood flow pulsatility characteristics in a group of patients with NPH before and after shunt tube insertion. I initially studied 18 subjects without pathology with MRI flow quantification studies of the cerebral arteries and veins to define the range of normality. The main study involved 18 patients with idiopathic dementia and mild leukoaraiosis who served as controls and seven patients with NPH studied before and after shunt insertion. Arterial, superior sagittal and straight sinus pulsatility was not significantly different between the patients with idiopathic dementia and those NPH patients before or after shunting. Cortical vein pulsatility before shunting in the patients with NPH was 43% lower than in those with idiopathic dementia ( P=0.006). Following shunting, cortical vein pulsatility increased by 186% ( P=0.007). There is thus reduced compliance in cortical veins in NPH which is significantly increased in patients who respond to insertion of a shunt tube. These findings suggest that reversible elevation in cortical vein pressure and reversal of the normal absorption pathway for cerebrospinal fluid may be behind the pathophysiology of NPH.

Adolescent↗

Pulsatile ocular blood flow study: decreases in exudative age related macular degeneration.

BACKGROUND: Pulsatile ocular blood flow (POBF) is a parameter for evaluating choroidal blood flow. POBF in the patients with non-exudative and exudative age related macular degeneration (AMD) was investigated. METHODS: POBF, pulse amplitude (PA), systolic and diastolic blood pressures, intraocular pressure (IOP), refractive error, and axial length were compared among 10 patients with non-exudative AMD, 11 patients with exudative AMD, and 69 age matched controls. A Langham OBF computerised tonometer was used with the participants in the sitting position to measure POBF and PA. RESULTS: No significant differences were found in age, systolic and diastolic blood pressures, IOP, or refractive error between patients with exudative and non-exudative AMD and the control subjects. In the patients with exudative AMD the POBF (median, 372.7 microl/min) and PA (median, 1.2 mm Hg) were significantly lower than in the patients with non-exudative AMD (median, 607.0 microl/min (p = 0.02) and 2.2 mm Hg (p = 0.04), respectively) and control subjects (median, 547.4 microl/min (p = 0.01) and 2.0 mm Hg (p = 0.01), respectively). CONCLUSIONS: These data show that the POBF and PA in the patients with exudative AMD are lower than in the patients with non-exudative AMD and normal subjects. Decreased choroidal blood flow may have a role in the development of choroidal neovascularisation in AMD.

Aged↗

Evaluation of the precision of magnetic resonance phase velocity mapping for blood flow measurements.

Evaluating the in vivo accuracy of magnetic resonance phase velocity mapping (PVM) is not straightforward because of the absence of a validated clinical flow quantification technique. The aim of this study was to evaluate PVM by investigating its precision, both in vitro and in vivo, in a 1.5 Tesla scanner. In the former case, steady and pulsatile flow experiments were conducted using an aortic model under a variety of flow conditions (steady: 0.1-5.5 L/min; pulsatile: 10-75 mL/cycle). In the latter case, PVM measurements were taken in the ascending aorta of ten subjects, seven of which had aortic regurgitation. Each velocity measurement was taken twice, with the slice perpendicular to the long axis of the aorta. Comparison between the measured and true flow rates and volumes confirmed the high accuracy of PVM in measuring flow in vitro (p > 0.85). The in vitro precision of PVM was found to be very high(steady: y = 1.00x + 0.02, r = 0.999; pulsatile: y = 0.98x + 0.72, r = 0.997; x: measurement #1, y: measurement #2) and this was confirmed by Bland-Altman analysis. Of great clinical significance was the high level of the in vivo precision (y = 1.01x - 0.04, r = 0.993), confirmed statistically (p = 1.00). In conclusion, PVM provides repeatable blood flow measurements. The high in vitro accuracy and precision, combined with the high in vivo precision, are key factors for the establishment of PVM as the "gold-standard" to quantify blood flow.

Aorta, Thoracic↗