Fracture of biliary endoprosthesis after endoscopic drainage for malignant biliary obstruction. Report of two cases.

The authors report two cases of fracture of a biliary endoprosthesis inserted endoscopically to treat malignant biliary obstruction. To their knowledge, such a complication has never been reported. In both cases, the fracture was revealed by cholangitis which occurred three and eight months after insertion. Successful treatment was achieved by replacement of the biliary stent.

Aged↗

Morphologic characteristics of periprosthetic tissues from hip prostheses with ceramic-ceramic couples: a comparative histologic investigation of 18 revision and 30 autopsy cases.

Pseudocapsules and interface membranes from 18 revision cases having hip prostheses with ceramic-ceramic couples and 30 autopsy specimens (6 with ceramic-ceramic couples, 7 with ceramic-polyethylene combinations and 17 with metal-polyethylene combinations) were histomorphologically analyzed, including a semiquantitative grading of the wear particles and histologic changes. Unlike the revision cases, which usually showed ceramic wear particles in the adjacent tissues, only half of the autopsy cases revealed ceramic wear. As compared to the ceramic-polyethylene and metal-polyethylene couples, the alumina on alumina combinations showed a thinner synovial layer with reduced villous transformation and smaller infiltrates of macrophages and necroses, which can be explained by the absence of polyethylene wear. Metal-polyethylene couplings produced more than twice as many polyethylene wear particles with correspondingly more marked foreign body reaction than the ceramic-polyethylene couplings.

Adult↗

Long-term results of cemented femoral stems with roughened precoated surfaces.

Several recent articles have raised the question that rough surfaces with or without precoating may contribute to the loosening of cemented femoral stems. In this article the author collates selected reports of several different cemented femoral stem designs that have rough surfaces which have shown excellent long term results. Femoral stem loosening is generally multifactorial. It often is difficult to separate the effect of stem design or other changes from the effect of surface finish. Many rough surfaced cemented femoral stems have served well for decades. It is important to analyze all the pertinent factors in cases of early loosening.

Aged↗

The role of proximal femoral support in stress development within hip prostheses.

Bone remodeling commonly associated with implant loosening may require revision total hip replacement when there is substantial proximal femoral bone loss. Additionally, the surgical exposure required to remove primary implants may alter the proximal femur's structure. As a result, in many revision hip situations the proximal femur provides compromised support for the revision femoral component. Stress analyses of the proximal femur with extensively porous-coated prosthetic femoral components show that proximomedial femoral bone loss, ununited femoral osteotomy, and periprosthetic fracture can result in significant elevation of stress within revision prosthetic components. The first principal stress within prosthetic components can, in proximal bone loss conditions, be elevated significantly above a revision prostheses' fatigue strength. Loss of proximomedial bone is predicted to increase stress within a revision component by as much as 82%. An unhealed transverse femoral fracture or osteotomy is predicted to more than double the stress within a revision femoral component. In revision total hip replacement, efforts directed toward the restoration of proximal femoral bone and the use of larger prostheses may contribute to avoiding prostheses fatigue fracture. Similarly, protected weightbearing in patients with ununited femoral osteotomies and periprosthetic fractures may be important to preventing prosthetic fracture.

Arthroplasty, Replacement, Hip↗

A 5-year audit of haemodialysis access.

This is a review of our experience with vascular access procedures over a 5-year period at Derriford Hospital, Plymouth, UK. The aims of the study were to examine the outcome of vascular access procedures and factors influencing access survival. Between April 1995 and March 2000, 151 patients who underwent 221 vascular access procedures were studied. Of these, 136 had autogenous arteriovenous fistulae, whereas 85 had prosthetic AV grafts (41% in the thigh). The overall primary failure rate was 21% whereas the 1- and 5-year cumulative access survival rates were 60 and 41%, respectively. Thigh grafts have a mean survival of 36 months compared with 32 months for prosthetic upper limb and 43 months for autogenous fistulae. Age, diabetes and predialysis status did not significantly influence access survival. Thrombosis was responsible for access failure in 62 cases (28%). Avoiding subclavian vein canulation and performing vessel mapping prior to access placement should reduce the risk of access failure due to outflow obstruction.

Adolescent↗

Appropriate result from an inappropriate ICD shock.

A case of inappropriate detection of an ungrounded external AC current by an implantable cardioverter defibrillator (ICD) is reported. The resultant ICD shock dislodged the patient from the electrical source, thus preventing injury or electrocution.

Defibrillators, Implantable↗

Local head roughening as a factor contributing to variability of total hip wear: a finite element analysis.

Large inter-patient variability in wear rate and wear direction have been a ubiquitous attribute of total hip arthroplasty (THA) cohorts. Since patients at the high end of the wear spectrum are of particular concern for osteolysis and loosening, it is important to understand why some individuals experience wear at a rate far in excess of their cohort average. An established computational model of polyethylene wear was used to test the hypothesis that, other factors being equal, clinically typical variability in regions of localized femoral head roughening could account for much of the variability observed clinically in both wear magnitude and wear direction. The model implemented the Archard abrasive/adhesive wear relationship, which incorporates contact stress, sliding distance, and (implicitly) bearing surface tribology. Systematic trials were conducted to explore the influences of head roughening severity, roughened area size, and roughened area location. The results showed that, given the postulated wear factor elevations, head roughening variability (conservatively) typical of retrieval specimens led to approximately a 30 degrees variation in wear direction, and approximately a 7-fold variation in volumetric wear rate. Since these data show that randomness in head scratching can account for otherwise-difficult-to-explain variations in wear direction and wear rate, third-body debris may be a key factor causing excessive wear in the most problematic subset of the THA population.

Acetabulum↗

Stress intensity factors for a vertical surface crack in polyethylene subject to rolling and sliding contact.

Pitting wear is a dominant form of polyethylene surface damage in total knee replacements, and may originate from surface cracks that propagate under repeated tribological contact. In the present study, stress intensity factors, KI and KII, were calculated for a surface crack in a polyethylene-CoCr-bone system in the presence of rolling or sliding contact pressures. Variations in crack length and load location were studied to determine probable crack propagation mechanisms and modes. The crack tip experienced a wide range of mixed-mode conditions that varied as a function of crack length, load location, and sliding friction. Positive KI values were observed for shorter cracks in rolling contact and for all crack lengths when the sliding load moved away from the crack. KII was greatest when the load was directly adjacent to the crack (g/a = +/- 1), where coincidental Mode I stresses were predominantly compressive. Sliding friction substantially increased both KImax and KIImax. The effective Mode I stress intensity factors, Keff, were greatest at g/a = +/- 1, illustrating the significance of high shear stresses generated by loads adjacent to surface cracks. Keff trends suggest mechanisms for surface pitting by which surface cracks propagate along their original plane under repeated reciprocating rolling or sliding, and turn in the direction of sliding under unidirectional sliding contact.

Chromium Alloys↗

An implantable radiation dosimeter for use in external beam radiation therapy.

An implantable radiation dosimeter for use with external beam therapy has been developed and tested both in vitro and in canines. The device uses a MOSFET dosimeter and is polled telemetrically every day during the course of therapy. The device is designed for permanent implantation and also acts as a radiographic fiducial marker. Ten dogs (companion animals) that presented with spontaneous, malignant tumors were enrolled in the study and received an implant in the tumor CTV. Three dogs received an additional implant in collateral normal tissue. Radiation therapy plans were created for the animals and they were treated with roughly 300 cGy daily fractions until completion of the prescribed cumulative dose. The primary endpoints of the study were to record any adverse events due to sensor placement and to monitor any movement away from the point of placement. No adverse events were recorded. Unacceptable device migration was experienced in two subjects and a retention mechanism was developed to prevent movement in the future. Daily dose readings were successfully acquired in all subjects. A rigorous in vitro calibration methodology has been developed to ensure that the implanted devices maintain an accuracy of +/-3.5% relative to an ionization chamber standard. The authors believe that an implantable radiation dosimeter is a practical and powerful tool that fosters individualized patient QA on a daily basis.

Animals↗

Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

PURPOSE: To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MATERIALS AND METHODS: MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. RESULTS: Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. CONCLUSION: Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves.

Adult↗

Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.

Wear of polyethylene and the resulting wear debris-induced osteolysis remains a major cause of long-term failure in artificial hip joints. There is interest in understanding engineering and clinical conditions that influence wear rates. Fluoroscopic studies have shown separation of the head and the cup during the swing phase of walking due to joint laxity. In ceramic-on-ceramic hips, joint laxity and microseparation, which leads to contact of the head on the superior rim of the cup, has led to localized damage and increased wear in vivo and in vitro. The aim of this study was to investigate the influence of joint laxity and microseparation on the wear of ceramic on polyethylene artificial hip joints in an in vitro simulator. Microseparation during the swing phase of the walking cycle produced contact of the ceramic head on the rim of the polyethylene acetabular cup that deformed the softer polyethylene cup. No damage to the alumina ceramic femoral head was found. Under standard simulator conditions the volume change of the moderately crosslinked polyethylene cups was 25.6 +/- 5.3 mm3/million cycles and this reduced to 5.6 +/- 4.2 mm3/million cycles under microseparation conditions. Testing under microseparation conditions caused the rim of the polyethylene cup to deform locally, possibly due to creep, and the volume change of the polyethylene cup when the head relocated was substantially reduced, possibly due to improved lubrication. Joint laxity may be caused by poor soft tissue tension or migration and subsidence of components. In ceramic-on-polyethylene acetabular cups wear was decreased with a small degree of joint laxity, while in contrast in hard-on-hard alumina bearings, microseparation accelerated wear. These findings may have significant implications for the choice of fixation systems to be used for different types of bearing couples.

Ceramics↗

Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces.

The effect of the roughness and topography of ultrahigh molecular weight polyethylene (UHMWPE) bearing surfaces on the microscopic contact mechanics with a metallic counterface was investigated in the present study. Both simple sinusoidal roughness forms, with a wide range of amplitudes and wavelengths, and real surface topographies, measured before and after wear testing in a simple pin-on-plate machine, were considered in the theoretical analysis. The finite difference method was used to solve the microscopic contact between the rough UHMWPE bearing surface and a smooth hard counterface. The fast Fourier transform (FFT) was used to cope with the large number of mesh points required to represent the surface topography of the UHMWPE bearing surface. It was found that only isolated asperity contacts occurred under physiological loading, and the real contact area was only a small fraction of the nominal contact area. Consequently, the average contact pressure experienced at the articulating surfaces was significantly higher than the nominal contact pressure. Furthermore, it was shown that the majority of asperities on the worn UHMWPE pin were deformed in the elastic region, and consideration of the plastic deformation only resulted in a negligible increase in the predicted asperity contact area. Microscopic asperity contact and deformation mechanisms may play an important role in the understanding of the wear mechanisms of UHMWPE bearing surfaces.

Computer Simulation↗

Effect of bone material properties on the initial stability of a cementless hip stem: a finite element study.

In previous finite element studies of cementless hip stems reported in the literature, the effect of bone quality on the initial micromotion and interface bone strain has been rarely reported. In this study, the effect of varying cortical and cancellous bone modulus on initial stem micromotion and interface bone strain was examined and the potential consequence of these changes on bone ingrowth and implant migration was reported. A finite element (FE) model of a total hip replacement (THR) was created and the Young's moduli of cortical and cancellous bone were systematically varied to study the relative effect of the quality of both types of bone on the initial stability of a cementless THR. It was found that the initial micromotion and interface bone strain in a THR was significantly affected by the overall stiffness of the femur. In other words, both the reduction of the modulus of cortical and cancellous bone caused an increase in the initial micromotion and interface bone strain. This suggests that for FE studies to be truly predictive, a range of bone quality must be examined to study the performance envelope of a particular stem and to allow comparison with clinical results.

Arthroplasty, Replacement, Hip↗

Revision stapedectomy.

The need for revision stapedectomy surgery still exists despite the many changes that have occurred in the surgical technique for the treatment of stapedial otosclerosis over the past 30 years. Sixty-six revision stapes operations were analyzed to determine the causes of failure of previously operated cases of stapedial otosclerosis, and to evaluate the hearing results following a revision stapedectomy. Failure was most often due to erosion of the incus (41%), displacement of the prosthesis from the incus (24%), or migration of the prosthesis from the center portion of the oval window (24%). Postoperative improvement of hearing was observed in 81% of ears operated on for a conductive hearing loss. Closure to within 10 dB, however, occurred in 61%. Two ears suffered a deterioration in the sensorineural hearing level following the revision surgery. Speech discrimination scores following revision surgery were improved in 5% of ears and unchanged in the remainder. Although the overall hearing results are less favorable than those seen in primary stapedectomy, revision stapedectomy surgery should continue to be offered to patients whose primary stapes surgery failed or whose initial good result declined over time.

Adult↗

The skeletal response to matt and polished cemented femoral stems.

We studied the effect of the surface finish of the stem on the transfer of load in the proximal femur in a sheep model of cemented hip arthroplasty. Strain-gauge analysis and corresponding finite-element (FE) analysis were performed to assess the effect of friction and creep at the cement-stem interface. No difference was seen between the matt and polished stems. FE analysis showed that the effects of cement creep and friction at the stem-cement interface on femoral strain were small compared with the effect of inserting a cemented stem.

Animals↗

Is titanium so bad?

Explore the source record for details and available documents.

Arthroplasty, Replacement, Hip↗