Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pliability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Antibacterial activity of resin composites with silver-containing materials.

Resin composites with antibacterial activity may be useful to decrease the frequency of secondary caries around restorations. The purposes of this study were to investigate the antibacterial activity of light-activated resin composites incorporating one of three silver-containing materials and to evaluate their long-term inhibitory effect against Streptococcus mutans The three types of silver-containing materials, Novaron (N), Amenitop (AM), and AIS, were incorporated into TEGDMA-UDMA-based light-activated resin composites, and the antibacterial activities, mechanical properties and release of silver ions were examined. Minimum inhibitory concentrations in suspensions of N, AM, and AIS against S. mutans were 1.1, 1.2, and 23.0 mg/ml, respectively. Resin composites incorporating 5 wt% of Novaron (N-5) and 7 wt% of Amenitop (AM-7) inhibited the growth of S. mutans after immersion in water for 3 months, whereas the resin composite incorporating 10 wt% of AIS did not. No significant difference in either compressive or flexural strength was observed between the control and N-5 composites after 1 d and 3 months storage in water. However, for AM-5 composite, there was a significant difference in both strength parameters between the two immersion periods. There was no or extremely little release of silver ions from the N-5 and AM-5 composites after 1 d or 3 months immersion in water. These results indicated that a light-activated resin composite incorporating silver-containing materials such as Novaron may be clinically useful due to its long-term inhibitory effect against S. mutans and favorable mechanical properties.

Aluminum Oxide↗

In vivo determination of muscle viscoelasticity in the human leg.

The purpose of this study was to examine the methodological validity of the free vibration technique for determining individual viscoelastic characteristics of the human triceps surae muscle-tendon complex (MTC) in vivo. Six subjects sat with first phalangeal joint of the forefoot on the edge of a force-plate. The special frame on the knee was loaded with weight (0-40 kg) for testing. Oscillations of the triceps surae MTC system were initiated with a hand-held hammer by tapping the weight. In order to keep the same posture, the output of the force plate was displayed on the oscilloscope and subjects were asked to maintain the beam on the oscilloscope at a particular location in relation to a reference line. The damped oscillations in conjunction with the equation of motion of a damped mass-spring model were used to calculate the viscosity of muscle (b) and the elasticity of muscle fibres and tendon (k) in each subject, considering moment arm of the ankle joint. With this arrangement, we have obtained high reproducibility in this method. The coefficient of variations (CVs) of b and k in five trials at each weight were quite small (range: 0.5-18.7% in b and 1.0-15.1% in k). There were no significant differences in viscoelastic coefficients between right and left legs. Therefore, it appears that free vibration technique, used here, is adequate in describing the viscoelastic characteristics of the triceps surae in vivo in humans.

Adult↗

Mechanics of human triceps surae muscle in walking, running and jumping.

Length changes of the muscle-tendon complex (MTC) during activity are in part the result of length changes of the active muscle fibres, the contractile component (CC), and also in part the result of stretch of elastic structures [series-elastic component (SEC)]. We used a force platform and kinematic measurements to determine force and length of the human calf muscle during walking, running and squat jumping. The force-length relation of the SEC was determined in dynamometer experiments on the same four subjects. Length of the CC was calculated as total muscle-tendon length minus the force dependent length of the SEC. The measured relations between force and length or velocity were compared with the individually determined force-length and force-velocity relations of the CC. In walking or running the negative work performed in the eccentric phase was completely stored as elastic energy. This elastic energy was released in the concentric phase, at speeds well exceeding the maximum shortening speed predicted by the Hill force-velocity relation. Speed of the CC, in contrast, was positive and low, well within the range predicted by the measured force-velocity properties and compatible with a favourable muscular efficiency. These effects were also present in purely concentric contractions, like the squatted jump. Contractile component length usually started at the far end of the force-length relation. Inter-individual differences in series-elastic stiffness were reflected in the force and length recordings during natural activity.

Adult↗

Assessment of adenoid size in children by fibreoptic examination.

In order to investigate the relationship between the size of the adenoid and upper respiratory symptoms in children, fibreoptic examination of the nasal cavity and nasopharynx was performed in 817 children. The size of the adenoid was classified into three categories according to the distance between the vomer and the adenoid tissue. There was a significant relation between the size of the adenoid and the complaints of nasal obstruction (P < 0.001) and of snoring (P < 0.001), but not with the presence of purulent sinusitis. In the whole population, the size of the adenoid correlated well with the results of tympanometry (P < 0.001), but this does not hold in all age groups. This study has confirmed adenoid hypertrophy as a common aetiological factor in children with the complaints of nasal obstruction and snoring. The enlargement of the adenoid only partially explains the occurrence of otitis media with effusion. The introduction of the flexible fibrescope in the examination of the nasal cavity and nasopharynx in children is of great clinical value, especially in the selection of children for adenoidectomy. It is a minor invasive examination well tolerated by most children, giving more information than a lateral skull radiograph and avoiding unnecessary radiation.

Acoustic Impedance Tests↗

Light-guided tracheal intubation using a prototype illuminated flexible catheter through the intubating laryngeal mask.

We evaluated the efficacy of a newly developed prototype illuminated flexible catheter to facilitate tracheal intubation through the intubating laryngeal mask and compared this light-guided technique with the conventional blind tracheal intubation through the intubating laryngeal mask. The illuminated flexible catheter consists of a completely flexible thin plastic catheter, a bulb attached to its distal end, a 15-mm concentric adapter at its proximal end connected with a battery and a power switch. The device is placed into a silicone tracheal tube in such a way that the bulb protrudes from the distal end of the tracheal tube. One hundred adult patients, ASA I-III, scheduled to undergo propofol/fentanyl/atracurium anaesthesia for elective surgery were studied. All participants underwent a randomized double comparative cross over trial with respect to the tracheal intubation technique through the intubating laryngeal mask. The light guided tracheal intubation was performed as follows; the tracheal tube preloaded with the illuminated flexible catheter was inserted through the intubating laryngeal mask and by observing the glow in the neck was advanced into the trachea. Whenever resistance was felt during insertion, appropriate adjusting manoeuvres were performed. The intubating laryngeal mask was inserted successfully in all patients. The success rate for the blind and light-guided technique was 91% and 100%, respectively (P = 0.003). The mean (+/- SD) duration including appropriate intubating laryngeal mask placement and tracheal intubation, was significantly lower in the light-guided tracheal intubation technique, than with the blind tracheal intubation (31 +/- 8 s vs. 43 +/- 18 s; P < 0.0001). We conclude that the use of an illuminated flexible catheter carries advantages either in optimizing the intubating laryngeal mask position in the laryngopharynx or in achieving a quick and safe light-guided advancement from laryngopharynx into the trachea.

Adult↗

Use of an illuminated flexible catheter for light-guided tracheal intubation through the intubating laryngeal mask by nurses.

We evaluated the ability of inexperienced personnel in using a prototype illuminated flexible catheter to assist tracheal intubation through the intubating laryngeal mask in anaesthetised, paralysed patients. The device consists of a completely flexible thin plastic catheter, a bulb attached to its distal end and a 15-mm concentric adapter at its proximal end. The illuminated catheter is placed into a straight silicone tracheal tube in such a way that the bulb is placed at the distal end of the tracheal tube. Six nurses inexperienced in tracheal intubation followed a 2-hr training program by using the device through the intubating laryngeal mask in a mannequin and then intubated 10 patients each, with instruction from an anaesthetist. All patients (n=60) were ASA 1-2, scheduled to undergo general anaesthesia for elective surgery. After fentanyl/propofol induction the intubating laryngeal mask was inserted. When an adequate airway was established, patients received atracurium and the endotracheal tube preloaded with the device was inserted through the intubating laryngeal mask and by observing the glow in the neck was advanced into the trachea. The final outcome and the duration of the procedure were recorded. The intubating laryngeal mask was inserted successfully in all patients. The success rate of intubation was 57/60 (95%); 38 patients at first attempt and 19 after two or three attempts. The mean (+/-SD) duration of the procedure in the first five patients in the series of each nurse was 74+/-40 s while in the last five patients it was diminished to 52+/-23 s (P=0.01). We conclude that the described methodology has the potential for more widespread use of tracheal intubation through the intubating laryngeal mask even by inexperienced personnel.

Adult↗

Newly developed resinous direct pulp capping agent containing calcium hydroxide (MTYA1-Ca).

AIM: The aim of this study was to evaluate a newly developed resin (MTYA1-Ca) for direct pulp capping. METHODOLOGY: The powder of MTY1-Ca is composed of 89.0% microfiller, 10.0% calcium hydroxide and 1.0% benzoyl peroxide and was mixed with liquid (67.5% triethyleneglycol dimethacrylate, 30.0% glyceryl methacrylate, 1.0% o-methacryloyl tyrosine amide, 1.0% dimethylaminoethylmethacrylate, and 0.5% camphorquinone). The shear bond, diametral tensile, bending and compressive strengths were measured. The alkaline activity of the elute dissolved from MTYA1-Ca was calculated. Cell viability by MTT assay and alkaline phosphatase (ALPase) activity were evaluated from dental pulp fibroblast reaction to the eluate dissolved from MTYA1-Ca. Histopathological studies of the response to exposed dental pulp of beagle dogs were completed with Dycal as a control. RESULTS: The physical properties of MTYA1-Ca were significantly superior to those of Dycal. It was impossible to measure these properties with Dycal because of poor physical properties. Both MTYA1-Ca and Dycal maintained high levels of alkaline activity (pH 10.96-12.20) over the 168-h duration of the study. Cell viability by MTT assay in the intact eluate of MTYA1-Ca was significantly higher than that of Dycal, whilst ALPase showed no difference between MTYA1-Ca and Dycal. A dentine bridge formed more slowly under MTYA1-Ca than under Dycal, but similar amounts had formed at 90 days. CONCLUSIONS: MTYA1-Ca has the potential to be used as a direct pulp capping material.

Analysis of Variance↗

Effect of exposing dentine to sodium hypochlorite and calcium hydroxide on its flexural strength and elastic modulus.

AIM: The aim of this study was to evaluate the effect of sodium hypochlorite (NaOCl) solutions (3%, 5%) and saturated calcium hydroxide (Ca(OH)2) solution, individually and consecutively, on the flexural strength and modulus of elasticity of standardized dentine bars. METHODOLOGY: Standardized plano-parallel dentine bars (n = 121) were divided into five test groups and one control group. The control group 1 consisted of dentine bars, stored in normal saline until testing. The dentine bars in the five test groups were treated by exposure to the following solutions; group 2--3% NaOCl, 2 h; group 3--5% NaOCl, 2 h; group 4--saturated Ca(OH)2 solution, 1 week; group 5--3% NaOCl, 2 h and then saturated Ca(OH)2 solution 1 week; group 6--5% NaOCl, 2 h and then saturated Ca(OH)2 solution 1 week. The dentine bars were then loaded to failure in a three-point bend test. RESULTS: The data revealed a significant (P < 0.001) decrease in the modulus of elasticity and flexural strength of the dentine bars treated with 3% and 5% NaOCl. There was no significant difference in the flexural strength and the modulus of elasticity between the 3% and 5% NaOCl groups. Exposure to Ca(OH)2 significantly (P < 0.001) reduced the flexural strength but had no significant effect on the modulus of elasticity. The groups treated with sodium hypochlorite followed by calcium hydroxide did not have moduli of elasticity and flexural strengths that were significantly different from those treated only with sodium hypochlorite. CONCLUSIONS: NaOCl (3 & 5%) reduced the modulus of elasticity and flexural strength of dentine. Saturated Ca(OH)2 reduced the flexural strength of dentine but not the modulus of elasticity. Sequential use of NaOCl and Ca(OH)2 has no additional weakening effect.

Calcium Hydroxide↗

Effect of sodium hypochlorite on mechanical properties of dentine and tooth surface strain.

AIM: The aim of this study was to test the null hypothesis that sodium hypochlorite irrigation of root canals does not alter the properties of dentine and contribute to the weakening of root-treated teeth. METHODOLOGY: The effect of two concentrations (0.5%, 5.25%) of sodium hypochlorite (NaOCl) and saline on (i) the elastic modulus and flexural strength of machined dentine bars, and (ii) changes in strain of 'whole' extracted human teeth were evaluated. One hundred standardized plano-parallel dentine bars (> 11.7 x 0.8 x 0.8 mm) were randomly divided into the three groups, immersed for 2 h in the respective solutions and then subjected to a three-point bend test. Changes in strain of each of 10 teeth on cyclical nondestructive occlusal loading were measured using electrical resistance strain gauges bonded to the cervical aspects. Each tooth had its crown and enamel reduced and root canal prepared. These were irrigated sequentially in a series of four separate, 30-minute regimes; initial-saline, 0.5% NaOCl, 5.25% NaOCl and final-saline. The changes in strains after each irrigation regime were compared. RESULTS: There was a significant decrease in elastic modulus of the dentine bars immersed in 5.25% NaOCl compared with the saline group (P < 0.01). There was also a significant decrease in flexural strength of the dentine bars in the 5.25% NaOCl group compared to both the saline and 0.5% NaOCl groups (P < 0.01). The strain data from the nondestructive tooth loading tests revealed significant increases in tensile strain between the initial-saline and the final-saline stages (P < 0.01). Significant increases in compressive strains were also found between initial-saline and 5.25% NaOCl; and between 0.5% NaOCl and 5.25% NaOCl stages (P < 0.01). CONCLUSIONS: The null hypothesis was rejected, 5.25% NaOCl reduced the elastic modulus and flexural strength of dentine. Irrigation of root canals of single, mature rooted premolars with 5.25% NaOCl affected their properties sufficiently to alter their strain characteristics when no enamel was present.

Analysis of Variance↗

Stainless steel bands in endodontics: effects on cuspal flexure and fracture resistance.

AIMS: This study investigated the effect of stainless steel bands on cuspal flexure and fracture resistance of extracted maxillary premolars. METHODOLOGY: Twenty extracted maxillary premolars (10 matched pairs) with mesio-occluso-distal (MOD) cavities and endodontic access were subjected to occlusal loading tests (100 N) using a servo-hydraulic testing machine. Cuspal deflections were measured by an extensometer, with and without the band present. Ten teeth (one of each pair) then had the band removed, and all teeth were subjected to loading until fracture. RESULTS: Mean cuspal flexure of teeth with bands was one-half of flexure without bands (P < 0.001). Teeth with bands fractured at higher load than their matched pairs with the band removed (P < 0.001), with mean loads at fracture of 1282 N and 729 N, respectively. CONCLUSIONS: The study showed that stainless steel bands used in endodontics reduce the cuspal flexure of maxillary premolars and increase their fracture resistance.

Adolescent↗

Smooth flexible versus active tapered shaft design using NiTi rotary instruments.

AIM: The aim of this study was to evaluate the influence of a smooth flexible versus active tapered shaft design on canal preparation by NiTi rotary techniques. METHODOLOGY: A XMCT-scanner (SkyScan 1072) and developed software (Bergmans et al. 2001) were used to nondestructively analyze the mesial canals of 10 extracted mandibular molars in 3D with a spatial resolution of 30 microm. Specimens (n = 10 per group) were scanned before (PRE) and after (POST) preparation using Lightspeed (smooth flexible) or GT-rotary (active tapered) files. Numerical values for volumes, dentine removal (net) transportation and centring ability were obtained in addition to a visual inspection on canal aberrations. Data were analyzed by Shapiro Wilk test, multiway factorial anova, Tukey-Kramer test, Wilcoxon test and t-test. RESULTS: Results indicated that the active tapered shaft removed significantly more dentine in the middle to apical portion of the root compared to the smooth flexible design. Both groups demonstrated some straightening, but no significant differences were found with respect to instrument types. However, absolute values for net transportation and centering ratio were small and no canal aberrations could be found. CONCLUSIONS: The smooth flexible shaft design did not improve the morphological characteristics of canal preparation by NiTi rotary instruments when compared with the active tapered design. Therefore, system selection should be based upon other criteria.

Analysis of Variance↗

Quality of preparation of oval distal root canals in mandibular molars using nickel-titanium instruments.

AIM: The aim of this study was to compare the preparation of oval distal root canals in mandibular molars using three different nickel-titanium (NiTi) instruments: Lightspeed (Lightspeed Inc., San Antonio, TX, USA). ProFile .04 (Maillefer Ballaigues. Switzerland) and Quantec SC (Tycom, Irvine, CA, USA). METHODOLOGY: Three groups of 20 extracted mandibular molars with oval distal root canals were embedded in a muffle system as described by Bramante et al. (1987) and modified by Hülsmann et al. (1999). Preparation of the root canals was performed with particular emphasis on the buccal and lingual extensions of the oval shape. The following parameters were evaluated: comparison of pre- and postoperative photographs with regard to the buccal and lingual extensions of the preparation, safety issues (file fractures, perforations, apical blockages, loss of working length), cleaning ability (SEM investigated using a 5-score system for remaining debris and smear layer) and working time. RESULTS: Superimposition of pre- and postoperative cross-sections in the majority of specimens revealed uninstrumented or incompletely instrumented buccal or lingual extensions (Lightspeed and Quantec SC, 56.7%; ProFile .04, 55%) For debris removal, Quantec SC achieved the best results (54.2% scores 1 and 2), followed by ProFile .04 (52.5%) and Lightspeed (46.7%). Preparation resulted in substantial smear layer covering the canal walls for every system (ProFile .04, 38.3%; Quantec SC, 36.6%; Lightspeed, 28.3%). Differences between the three systems were not significant for any of the parameters investigated. Preparation with Lightspeed resulted in two fractured instruments; with Quantec SC. two apical blockages occurred. With ProFile .04, no complications were noticed. Mean working time was shorter for ProFile .04 (261.2 s) than for Quantec SC (272.4 s) and Lightspeed (338.9 s); the differences were not significant. CONCLUSIONS: The flexibility of the NiTi instruments investigated in this study did not allow controlled preparation of the buccal and lingual extensions of oval root canals. The instruments frequently produced a circular bulge in the canal whilst the buccal and lingual extensions remained unprepared, leaving smear layer and debris.

Dental Alloys↗

Factors influencing the fracture of nickel-titanium rotary instruments.

AIM: To evaluate the effect of rotational speed and the angle and radius of curvature of root canals on the fracture of two types of nickel-titanium rotary instruments: K3 and ProTaper. METHODOLOGY: A total of 240 root canals of extracted human maxillary and mandibular molars were divided into two groups of 120, according to the angle of the canal curvature (group A: <30 degrees, group B: >30 degrees). Each group was then divided into two subgroups of 60 canals in order to perform instrumentation using K3 and ProTaper rotary instruments at three different rotational speeds: 150, 250 and 350 r.p.m. (20 canals at each rotational speed). Each instrument was used a maximum of 20 times and at one rotational speed only. The angle and radius of canal curvature were measured in the only group in which fractures actually took place (group B). RESULTS: There were a total of 22 instrument fractures; all of these occurred in canals with curves >30 degree. In a multivariate analysis, it was demonstrated that the files used at a rotational speed of 350 r.p.m. were more likely to fracture than those used at 250 r.p.m. (OR: 1113.88; 95% CI: 2.36-526420.05) and than those used at 150 r.p.m. (OR: 13531.33; 95% CI: 5.37-34120254.00). A decrease in the angle of curvature of the canal also significantly reduced the likelihood of fracture (OR: 0.2083; 95% CI: 0.068-0.6502). These relationships remained significant after being adjusted for the potential interactions between the remaining variables. No significant differences were found between the files or the radii of the canals. CONCLUSIONS: Instrument fracture was associated with rotational speed and the angle of curvature of the canal.

Dental Alloys↗

The effect of cleaning procedures on fracture properties and corrosion of NiTi files.

AIM: To evaluate the effect of repeated cleaning procedures on fracture properties and corrosion of nickel-titanium (NiTi) files. METHODOLOGY: New NiTi instruments were subjected to 2, 5 and 10 cleaning cycles with the use of either diluted bleach (1% NaOCl) or Milton's solution (1% NaOCl plus 19% NaCl) as disinfectant. Each cleaning cycle consisted of scrubbing, rinsing and immersing in NaOCl for 10 min followed by 5 min of ultrasonication. Files were then tested for torsional failure and flexural fatigue, and observed for evidence of corrosion using scanning electron microscope (SEM). Four brands of NiTi files were immersed in either Milton's solution or diluted bleach overnight and evaluated for corrosion. RESULTS: Up to 10 cleaning cycles did not significantly reduce the torque at fracture or number of revolutions to flexural fatigue (P > 0.05, two-way anova), although decreasing values were noted with increasing number of cleaning cycles using Milton's solution. No corrosion was detected on the surface of these files. Files immersed in 1% NaOCl overnight displayed a variety of corrosion patterns. The extent of corrosion was variable amongst different brands of files and amongst files in each brand. Overall, Milton's solution was much more corrosive than diluted bleach. Corrosion of file handles was often extreme. CONCLUSIONS: Files can be cleaned up to 10 times without affecting fracture susceptibility or corrosion, but should not be immersed in NaOCl overnight. Milton's solution is much more corrosive than bleach with the same NaOCl concentration.

Analysis of Variance↗

Properties of glass--ceramic materials for fixed partial denture construction.

In order to determine the feasibility of constructing fixed partial dentures using glass-ceramic materials, the flexural strength and marginal fit of three experimental glass ceramic materials, and DICOR as control, were studied. The flexural strength ranged from 105.8 MPa to 129.5 MPa. Ceramic and alumina addition provided significant strength as tested by ANOVA and multiple range tests (P < 0.05). The range for the cemented bridge margins was from 48.9 microns to 80.4 microns. The tested ceramics had no statistically significant differences in margin openings for the same sites (P < 0.05). However, the openings on the mesial side of the premolar abutment and the distal end of the molar abutment of the fixed partial denture did have statistically significant differences (P < 0.01). Appropriate addition of alumina led to an increase in bending strength. The alumina stabilizes and strengthens the glass-ceramic material by incorporation into the silicone network.

Aluminum Oxide↗

A comparative study of flexible (Polyactive) versus rigid (hydroxylapatite) permucosal dental implants. II. Histological aspects.

Of the many materials that are applied in dental implantology, most have a high Young's modulus. In the concept of osseointegration, which is generally preferred, chewing forces are therefore directly transmitted from rigid implant materials to the relatively flexible surrounding bone. Polyactive is an elastomeric polyethylene-oxide polybutylene-terephthalate (PEO:PBT) copolymer, with a low modulus of elasticity, that exhibits bone-bonding characteristics. Previous finite-element analysis emphasized the benefit of the application of flexible implant materials. To assess the validity of this finite element model, one dense and two porous types of flexible Polyactive permucosal dental implants and one rigid hydroxylapatite (HA) implant were clinically tested in a beagle dog study and were compared during 30 weeks of loading. In an earlier report, it was concluded that dense Polyactive implants function clinically adequately and resemble the mobility of natural teeth. In the current study, the amount of bone contact was quantitatively assessed. Polyactive implants showed a statistically significantly higher bone contact, as compared to the HA implants, probably due to a significant water uptake and a subsequent increase in the volume of the denser Polyactive. Morphological analysis, based on back-scatter electron microscopy and light microscopy, revealed little remodelling activity of the bone surrounding the Polyactive implants. Few remodelling lacunae were seen and de novo bone formation was rarely observed. At some locations, a continuity between calcification zones with the polymer surface and the surrounding interfacial bone was observed, indicating the occurrence of bone-bonding. Also, the bone surrounding the HA implants showed little remodelling activity, although large resorption lacunae were observed, in which HA particles were present. Based on the observations of this study, flexible bone bonding implants might be more capable of transferring stresses to the surrounding bone and are therefore promising alternatives to "routine' rigid implants.

Alveolar Process↗

Experimental wax mixtures for dental use.

Improvements in the properties of dental waxes were sought by alterations in their composition. Twenty-six blends of paraffin wax, beeswax and inorganic filler were subjected to the following tests: plastic deformation (flow), linear thermal expansion, elastic modulus and flexural strength. Flow tests were conducted in accordance with the corresponding ISO specification. Thermal expansion coefficients were estimated using thermomechanical analysis. Mechanical properties were tested using a universal testing machine. Pure paraffin and beeswax were used as controls. The results were subjected to analysis using correlation and regression. Regression coefficients in the range of 0.90-0.99 were obtained in most cases, flow tests exhibiting the highest coefficients and flexural strength the lowest. The incorporated filler particles reduced the flow of the natural waxes, especially of the ester-containing beeswax, and improved the elastic modulus and strength. Good correlation was found between the ingredient proportions and measured properties, suggesting a relationship between them, although this is quite complicated in the case of tertiary wax mixtures. The experimental blends exhibited properties that are potentially useful for a range of clinical applications.

Chemical Phenomena↗

In vitro evaluation of a glass-ceramic restorative material.

The aim of the present study was to evaluate the clinically relevant properties of the recently introduced ceramic material IPS Empress, which is marketed for all-ceramic restorations. The following parameters were investigated: three- and four-point bending strength, bi-axial flexure strength, compressive and diametral tensile strength, compressive strength and marginal fit of full crowns. The results show that this material is a highly developed glass-ceramic with physical properties making this dental material well suitable for adhesively luted restorations.

Adhesives↗