Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Meridians”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Capsulorhexis ovaling and capsular bag stretch after rigid and foldable intraocular lens implantation: experimental study in pediatric human eyes.

PURPOSE: To compare the amount of capsulorhexis ovaling and capsular bag stretch produced by various intraocular lenses (IOLs) implanted in pediatric human eyes obtained post-mortem. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, Salt Lake City, Utah, USA. METHODS: In this nonrandomized comparative study, 16 pediatric human eyes obtained postmortem were divided into 2 groups: Eight eyes were obtained from children younger than 2 years (Group A), and 8 eyes were obtained from children older than 2 years (Group B). All eyes were prepared according to the Miyake-Apple posterior video technique. Six types of rigid and foldable posterior chamber IOLs manufactured from poly(methyl methacrylate) (single-piece), silicone (plate and loop haptics), and hydrophobic acrylic (single-piece and 3-piece AcrySof, Alcon Laboratories) biomaterials were implanted. The capsulorhexis opening and capsular bag diameters were measured before IOL implantation and after in-the-bag IOL fixation with the haptics (or the main axis) at the 3 to 9 o'clock meridian. The percentage of ovaling of the capsulorhexis opening was calculated by noting the difference in the opening's horizontal diameter before and after IOL implantation. The percentage of capsular bag stretch was also calculated by noting the difference in the horizontal capsular bag diameter before and after IOL implantation. RESULTS: All IOLs produced ovaling of the capsulorhexis opening and stretching of the capsular bag parallel to the IOL haptics. There were significant differences in capsulorhexis ovaling and capsular bag stretch (P<.001, analysis of variance) between the 6 IOL types in each group of eyes. The postimplantation difference was significant only between the single-piece hydrophobic acrylic IOL (AcrySof) and the other IOLs. The single-piece hydrophobic acrylic IOL was associated with significantly less capsulorhexis ovaling and capsular bag stretch in both groups (mean 12.06% +/- 0.59% [SD] and 7.6% +/- 1.47%, respectively). CONCLUSIONS: Modern rigid and foldable IOLs designed for the adult population implanted in the capsular bag of infants and children produced variable degrees of capsulorhexis ovaling and capsular bag stretch. The Miyake-Apple posterior video technique confirmed the well-maintained configuration of the capsular bag (with minimal ovaling) after implantation of a single-piece hydrophobic acrylic IOL because of its flexible haptic design.

Capsulorhexis↗

Clinical results of ZSAL-4 angle-supported phakic intraocular lenses in 190 myopic eyes.

PURPOSE: To evaluate the efficacy and safety of angle-supported phakic intraocular lenses (IOLs) in myopia. SETTING: Private practice, Siena, Italy. METHODS: This prospective noncomparative single-surgeon interventional case series comprised 190 consecutive myopic eyes of 115 patients having implantation of a ZSAL-4 IOL (Morcher GmbH) through a 5.5 mm x 3.0 mm sclerocorneal tunnel along the steepest meridian with a surgical iridectomy. Preoperatively, the mean spherical equivalent was -14.37 diopters (D) +/- 4.40 (SD) and the mean astigmatism, 1.66 +/- 1.36 D. RESULTS: Postoperatively, the mean defocus equivalent (DEQ) was 1.55 +/- 1.06 D and the mean astigmatism, 1.41 +/- 1.11 D. The mean surgically induced astigmatism (vector analysis) was 1.03 +/- 0.77 D (95% confidence interval [CI], 0.92 to 1.15); 146 eyes (77%) were within +/-2.0 D of the DEQ, 76 eyes (40%) were within +/-1.0 D, and 36 eyes (19%) were within +/-0.5 D. The safety index was 1.25 and the efficacy index, 0.78. The improvement in best spectacle-corrected visual acuity (0.17) was statistically significant (95% CI, 0.14 to 0.2). Complications were intraocular pressure spike due to topical steroids, 18%; chronic iridocyclitis, 1%; explantation of unstable IOL, 1%; explantation of IOL for iridocyclitis, 0.5%; pupil ovalization, 11%; halos, 18%; and macular hemorrhage, 1%. CONCLUSIONS: Angle-supported IOLs can effectively correct high myopia, although residual refractive errors may require secondary procedures. The main intraoperative and postoperative complications were halos, steroid response, and incorrect IOL sizing. The role of surgery in inducing macular hemorrhages should be assessed further.

Adult↗

Effect of instrument rotation on handheld keratometry.

PURPOSE: To study the effect of instrument rotation on handheld automated keratometry. SETTING: Department of Optometry and Radiography, The Hong Kong Polytechnic University, Hong Kong SAR, China. METHODS: In 33 recruited subjects, corneal curvature in 1 eye (randomly selected) was measured using a Medmont topographic keratometer and a Nidek handheld keratometer. In handheld keratometry, measurements were obtained holding the instrument in the upright position and rotating it anticlockwise 5 degrees, 10 degrees, and 15 degrees and then clockwise 5 degrees, 10 degrees, and 15 degrees. The sequence of measurements was randomly assigned. The steepest and flattest corneal curvatures as well as the axis along the flattest meridian were compared in different conditions. The corneal power was converted to vector representation (M, J0, J45) for a second comparison. RESULTS: There was a significant difference in the steepest and flattest curvatures in different conditions (repeated-measures analysis of variation, P<.05). However, the mean difference between handheld and topographic keratometry was approximately 0.25 diopter (D) for the steepest curvature and 0.05 D for the flattest curvature regardless of the direction and amount of rotation. The intraclass correlation coefficients were nearly 1, which indicated good clinical reliability. The mean difference in axis determination followed the direction and amount of rotation. With vector representation, the difference between the devices increased with the amount of rotation, especially J0 and J45. CONCLUSIONS: Handheld keratometry was in agreement with topographic keratometry. However, practitioners should adjust the axis manually according to the direction and amount of rotation. The difference between handheld and topographic keratometry increased with the rotational effect, which was seen with vector representation. Practitioners are advised to use the handheld keratometer in the upright position.

Adult↗

Zonular dialysis and vitreous loss with a J-shaped hydrodissection cannula during phacoemulsification.

We report a complication that occurred during clear corneal phacoemulsification. When saline was injected during hydrodissection with a 27-gauge J-shaped cannula attached to a 2.0 mL luer-lock polypropylene syringe, the cannula dislodged and slipped behind the iris, hooking to the lens equator. Although the cannula was carefully removed, 3 clock hours of zonular dialysis were observed between the 4 o'clock and 7 o'clock meridians. After phacoemulsification, lens aspiration, and in-the-bag intraocular lens implantation, vitreous was noted inferiorly and the anterior vitrectomy was completed.

Aged↗

Angle-supported phakic intraocular lenses in hyperopia.

PURPOSE: To evaluate the efficacy and safety of angle-supported phakic intraocular lenses (PIOLs) in hyperopia. SETTING: Private practice, Siena, Italy. METHODS: A prospective noncomparative single-surgeon interventional case series comprised 42 consecutive hyperopic eyes of 22 patients having implantation of a type PIOL (Morcher) through a sclero-corneal 5.5 mm x 3.0 mm tunnel along the steepest meridian, with surgical iridectomy. The mean preoperative defocus equivalent (DEQ) was 7.30 diopters (D) +/- 1.89 (SD). The mean spherical equivalent (SE) was 6.61 +/- 1.47 D (range 4.0 to 10.5 D), and the mean refractive astigmatism was 1.51 +/- 1.33 D (range 0 to 5 D). The mean age was 29.9 +/- 6.0 years (range 22 to 42 years). Thirteen patients (59%) were men. RESULTS: Postoperative mean SE was 0.38 +/- 0.52 D (range 0 to 2 D); mean DEQ 0.93 +/- 0.98 D; mean astigmatism 0.95 +/- 1.17 D; mean surgically induced astigmatism (vector analysis) 0.67 +/- 0.58 D (95% confidence interval, 0.49-0.85); 38 eyes (90%) were within +/-2 D of DEQ, 34 eyes (81%) within +/-1 D, and 24 eyes (57%) within +/-0.5 D. Safety index was 1.05; efficacy index 0.85. Complications were night halos 10%; pupil ovalization 7%; pupillary block reversed by neodymium:YAG laser 7%; monocular anterior subcapsular opacity 5%; monocular iridocyclitis 5%; and intraocular pressure rise due to topical steroids 2%. Endothelial cell loss at 12 month was 6% (range +2.5% to -11%). CONCLUSION: High hyperopia was corrected safely and predictably by an angle-supported PIOL with limited complications.

Adult↗

Biometry of phakic intraocular lens using Scheimpflug photography.

PURPOSE: To examine lateral and axial positioning of phakic intraocular lenses (IOLs) with iris fixation in the anterior chamber and to examine short-term stability of the IOL position. SETTING: The Netherlands Opthalmic Research Institute, Amsterdam, the Netherlands. METHODS: Thirty patients participated in the study. Thirty-one eyes were implanted with the 204 type myopia IOL, 14 eyes with the 206 myopia IOL, and 8 eyes with the 203 hyperopia IOL. Scheimpflug slitlamp photographs were made through the optical axis along 4 meridians of the eyes. Ray tracing was used to obtain the lateral and axial position of the IOLs. RESULTS: Centration of the IOL with respect to the pupil's center and the tilt angle of the IOL with respect to the optical axis of the eye were measured. Standard deviation of decentration was 0.21 mm vertically and 0.16 mm horizontally. Standard deviation of tilt was 1.30 degrees vertically and 0.90 degrees horizontally. Tilt and decentration are proportional to each other. Vaulting, the distance between the crystalline lens and the IOL, was constant over a period of 24 months, ranging from 0.2 to 0.8 mm, depending primarily on the radius of curvature of the crystalline lens. A geometric model for this dependence was formulated. CONCLUSION: Phakic IOLs with iris fixation can be positioned in the eye with submillimeter precision. Axial position of iris-fixated phakic IOLs over time is excellent. Axial position and vaulting can be predicted when the radius of curvature of the crystalline lens is known. The IOL behaves as if mounted slightly above a sphere-the anterior surface of the crystalline lens.

Biometry↗

Effective corneal refractive diameter as a function of the object tangent angle in visual space.

PURPOSE: To determine whether the currently accepted method of selecting a minimum optical zone diameter for laser refractive surgery that is equal to or slightly greater than the dark-adapted pupil diameter provides a sufficient diameter of corneal surface to focus light arising from objects in the paracentral and peripheral visual field. SETTING: Department of Ophthalmology and Visual Sciences, Texas Tech University Health Sciences Center, Lubbock, Texas, USA. METHODS: An optical model of the anterior segment was developed to calculate the effective corneal refractive diameter (ECRD), which is the diameter of the area of cornea that refracts all incident light rays arising from an object through the physical pupil (PP). This model incorporates the patient variables of central anterior chamber depth (ACD), central corneal curvature (K(c)), and the diameter of the apparent entrance pupil (EP). The model was expanded to incorporate distant objects off the line of sight (LOS), described by their angular displacement from the fixation object in visual space (the object tangent angle delta(ob)). Results were calculated for the 360 meridian degree visual field (ie, for all objects in visual space perceptually displaced from the fixation object by angle delta(ob)). The effect of the prolate nature of the cornea was also investigated. RESULTS: The ECRD expanded rapidly as a function of PP and delta(ob) but was minimally influenced by K(c). Beyond a critical object tangent angle delta(c), light rays striking the corneal vertex were not refracted through the PP, and the ECRD became an annular surface centered on the corneal vertex. The delta(c) was not a function of K, but increased as the PP increased and decreased as the ACD increased. The prolate nature of the cornea had little influence on the ECRD, even for very peripheral light rays. CONCLUSIONS: The ECRD expands rapidly when considering distant objects only slightly displaced from the LOS. A patient treated with an optical zone equal to or slightly greater than the dark-adapted pupil diameter may experience vision quality loss for paracentral and midperipheral objects even under conditions of ambient indoor lighting.

Cornea↗

Surgically induced astigmatism after phacoemulsification in eyes with mild to moderate corneal astigmatism: temporal versus on-axis clear corneal incisions.

PURPOSE: To determine whether there is a difference in surgically induced astigmatism (SIA) and postoperative uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) between 2 types of clear corneal incisions used in phacoemulsification: the temporal and the on-axis (ie, on the steeper corneal meridian) clear corneal incision (CCTI and CCOI, respectively). SETTING: Moorfields Eye Hospital, London, United Kingdom. METHODS: In a prospective randomized controlled trial (pilot study), 61 eyes with cataract and mild to moderate corneal astigmatism (<2.58 diopters [D] on corneal topography) having phacoemulsification (single surgeon, 3.2 mm incision) were randomized to receive CCTI or CCOI. Main outcome measures included postoperative BCVA and corneal astigmatism and SIA (calculated using the Holladay vector analysis formula). Measurements were repeated postoperatively at 3 weeks in all eyes, whereas only 46 eyes made it to the final assessment at 8 weeks. Continuous variables between groups were compared by Student t test. The power of the study was calculated. RESULTS: At the first follow-up, the difference in SIA between the 2 incision types was 0.15 D and it was not statistically significant (0.65 D in CCOI; 0.50 D in CCTI). At the second follow-up, the difference was 0.29 D and it was statistically significant (0.63 D in CCOI; 0.34 D in CCTI; P = .0004). There was no statistically significant difference in the final postoperative visual acuity. The power of the pilot study was 72%. CONCLUSION: Seven weeks after small-incision phacoemulsification, the CCTI induced less SIA than the CCOI; however, there were no significant differences in the final UCVA and BCVA.

Aged↗

Anterior segment OCT and phakic intraocular lenses: a perspective.

Perfect tolerance is expected when one implants a phakic intraocular lens (pIOL) in the anterior segment. Not only should the material be compatible, but the pIOL must respect the anatomy of the anterior chamber. Based on 3 years of experience using an anterior segment optical coherence tomographer (Visante OCT, Carl Zeiss Meditec), I have defined numerous safety criteria for pIOLs. The internal dimensions of the anterior chamber must be considered along different meridians. I propose an objective measurement of the iris dome, the crystalline lens rise (CLR), which is the distance between the anterior pole of the crystalline lens and a line joining the 2 opposite iridocorneal angles. In a series with the Artisan IOL (Ophtec), pigment dispersion syndrome appeared in 70% of cases in which the CLR was greater than 600 microm. Angle-supported IOLs must be placed relative to the anterior chamber's largest diameter; in the same series of cases, the anterior chamber was oval with a large vertical axis in 74% of cases. The posterior face of an angle-supported IOL must have a 700 microm vault to respect the physiological modifications of the crystalline lens. It is difficult to know the posterior chamber's exact diameter as it varies with the horizontal or vertical axis. It also undergoes constant modifications due to accommodation and aging.

Adult↗

Evaluation of Chapman's neurolymphatic reflexes via applied kinesiology: a case report of low back pain and congenital intestinal abnormality.

OBJECTIVE: To describe the applied kinesiologic evaluation of Chapman's neurolymphatic (NL) reflexes in the management of a person with an unusual congenital bowel abnormality and its role in the manifestation of low back pain. The theoretical foundations of these reflexes will be elaborated on and practical applications discussed. CLINICAL FEATURES: A 29-year-old man had chronic low back pain. Radiographs of the patient's lumbar spine and pelvis were normal. Magnetic resonance imaging (MRI) demonstrated a mild protrusion of the fifth lumbar disk. Oral anti-inflammatory agents, cortisone injections, and chiropractic manipulative therapy provided little relief. Though generally in robust health, the patient was aware of a congenital intestinal abnormality diagnosed when he was a child; it was thought to be of no consequence with regard to his current back condition. INTERVENTION AND OUTCOME: The patient's history, combined with applied kinesiology examination, indicated a need to direct treatment to the large bowel. The essential diagnostic indicators were the analysis of the Chapman's neurolymphatic reflexes themselves, coupled with an evaluation of the traditional acupuncture meridians. The primary prescribed therapy was the stimulation of these reflexes by the patient at home. This intervention resulted in the resolution of the patient's musculoskeletal symptomatology, as well as improved bowel function. CONCLUSION: The rather remarkable outcome from the application of this relatively simple, yet valuable, diagnostic and therapeutic procedure represents a thought-provoking impetus for future study and clinical application.

Acupuncture Points↗

Spatial resolution of EEG cortical source imaging revealed by localization of retinotopic organization in human primary visual cortex.

The aim of the present study is to investigate the spatial resolution of electroencephalography (EEG) cortical source imaging by localizing the retinotopic organization in the human primary visual cortex (V1). Retinotopic characteristics in V1 obtained from functional magnetic resonance imaging (fMRI) study were used as reference to assess the spatial resolution of EEG since fMRI can discriminate small changes in activation in visual field. It is well known that the activation of the early C1 component in the visual evoked potential (VEP) elicited by pattern onset stimuli coincides well with the activation in the striate cortex localized by fMRI. In the present experiments, we moved small circular checkerboard stimuli along horizontal meridian and compared the activations localized by EEG cortical source imaging with those from fMRI. Both fMRI and EEG cortical source imaging identified spatially correlated activity within V1 in each subject studied. The mean location error, between the fMRI-determined activation centers in V1 and the EEG source imaging activation peak estimated at equivalent C1 components (peak latency: 74.8+/-10.6 ms), was 7 mm (25% and 75% percentiles are 6.45 mm and 8.4 mm, respectively), which is less than the change in fMRI activation map by a 3 degrees visual field change (7.8 mm). Moreover, the source estimates at the earliest major VEP component showed statistically good correlation with those obtained by fMRI. The present results suggest that the spatial resolution of the EEG cortical source imaging can correctly discriminate cortical activation changes in V1 corresponding to less than 3 degrees visual field changes.

Adult↗

Evidence for implication of primate area V1 in neural 3-D spatial localization processing.

We investigated the neural mechanisms underlying visual localization in 3-D space in area V1 of behaving monkeys. Three different sources of information, retinal disparity, viewing distance and gaze direction, that participate in these neural mechanisms are being reviewed. The way they interact with each other is studied by combining retinal and extraretinal signals. Interactions between retinal disparity and viewing distance have been shown in foveal V1; we have observed a strong modulation of the spontaneous activity and of the visual response of most V1 cells that was highly correlated with the vergence angle. As a consequence of these gain effects, neural horizontal disparity coding is favoured or refined for particular distances of fixation. Changing the gaze direction in the fronto-parallel plane also produces strong gains in the visual response of half of the cells in foveal V1. Cells tested for horizontal disparity and orientation selectivities show gain effects that occur coherently for the same spatial coordinates of the eyes. Shifts in preferred disparity also occurred in several neurons. Cells tested in calcarine V1 at retinal eccentricities larger than 10 degrees , show that horizontal disparity is encoded at least up to 20 degrees around both the horizontal and vertical meridians. At these large retinal eccentricities we found that vertical disparity is also encoded with tuning profiles similar to those of horizontal disparity coding. Combinations of horizontal and vertical disparity signals show that most cells encode both properties. In fact the expression of horizontal disparity coding depends on the vertical disparity signals that produce strong gain effects and frequent changes in peak selectivities. We conclude that the vertical disparity signal and the eye position signal serve to disambiguate the horizontal disparity signal to provide information on 3-D spatial coordinates in terms of distance, gaze direction and retinal eccentricity. We suggest that the relative weight among these different signals is the determining factor involved in the neural processing that gives information on 3-D spatial localization.

Animals↗

Optical imaging of the retinotopic organization of V1 in the common marmoset.

We examined the retinotopic mapping of the visual world in the primary visual cortex of the marmoset monkey using differential optical imaging. Two sets of complementary stripe-like locations were visually stimulated in turn. Their difference depicts the cortical representations of continuous bands of visual space. By rotating the sets of stripe-like locations it is possible to map different spatial axes. Analogous to the macaque we found that the V1/V2 border represented the vertical meridian, while horizontal, 45-, and 135-degree angled stripes of space were also represented in a continuous manner. We developed a new automatic method of calculating local measures of cortical magnification from our optical retinotopic maps. Using this method we found no evidence of any local anisotropies in cortical representation. Overall our results indicate that space is mapped isotropically in the primary visual cortex of the common marmoset.

Algorithms↗

Effective binocular integration at the midline requires the corpus callosum.

To study the role of the corpus callosum (CC) in midline binocular integration, the effects of late callosotomy and congenital CC agenesis on the ability to perceive dichoptic plaid motion was assessed. Coherent motion was well perceived at all locations in the visual field under dioptic viewing but not along the vertical meridian (VM) when the components were dichoptically presented. This deficit was totally abolished in the agenesis subject and reduced in the callosotomized individual when stimulus size was increased beyond the VM. Electrophysiological correlates were also examined by recording visual evoked potentials and these showed that the P1/N2 components were abnormal for small dichoptic stimuli presented on the midline. These findings attest to the importance of the contribution of CC to midline binocular integration and the effects of cerebral plasticity.

Adult↗

What kind of visual spatial attention is impaired in neglect?

The distribution of spatial attention across the horizontal meridian of the visual field, as assessed by a simple reaction time (RT) paradigm, is dramatically abnormal in neglect patients. In the contralesional hemifield, RT increases sharply from centre to periphery, while in the ipsilesional hemifield, it decreases paradoxically from centre to mid-periphery. In the present study, we firstly asked whether this abnormal distribution of spatial attention is still present when patients know in advance the location of the impending stimulus, and second whether and to which extent it may be influenced by the concomitant presence of hemianopia. In Experiment 1, the stimuli were presented either predictably (blocks of same-point presentations) or unpredictably (blocks of randomised presentations) to one of several contralesional and ipsilesional field locations. As was the case for control subjects, neglect patients showed an overall RT decrease with same-point presentations. However, their abnormal contralesional RT lengthening and ipsilesional speeding were still present. In Experiment 2, the trials were blocked to same-hemifield presentations. In the ipsilesional field condition, neglect patients with and without hemianopia showed the same distorted distribution of attention favouring mid-periphery over central field locations. Two conclusions can be drawn from these experiments: first, the bulk of the abnormal deployment of spatial attention in neglect patients is related to an impairment of exogenous attention which cannot be compensated for by a spared endogenous control. Second, hemianopia does not affect the paradoxical speeding up of RT typically found in the mid-periphery of the ipsilesional field of neglect patients.

Adolescent↗

Form completion across a hemianopic boundary: behindsight?

Patients with homonymous hemianopia may report the completion of forms that overlap the vertical meridian of their field defects. While previous investigations of "hemianopic completion" have variously attributed to the disorder to inattention, residual vision or unstable fixation, we believe that our investigation has controlled for such potentially confounding factors. We report patient P.O.V. who experienced hemianopic completion in everyday life following a surgical lesion of his left occipital lobe. He showed normal spatial attention and normal spatial orienting: hemianopic completion can therefore occur in the absence of inattention. His completion was retinotopic and affected partial as well as complete forms: his hemianopic completion cannot be attributed to residual visual input or poor fixation. P.O.V.'s completion was also systematically affected by varying stimulus contrast and pattern masking. We argue that while other explanations may be appropriate for different cases, P.O.V.'s hemianopic completion reflects normal "constructive" visual processes and can be attributed to the unconstrained operation of visual routines that are normally involved in the perception of partially occluded forms. As such, this disorder has the potential to shed light on some of the most basic aspects of visual perception.

Aged↗

Retinotopic effects during spatial audio-visual integration.

The successful integration of visual and auditory stimuli requires information about whether visual and auditory signals originate from corresponding places in the external world. Here we report crossmodal effects of spatially congruent and incongruent audio-visual (AV) stimulation. Visual and auditory stimuli were presented from one of four horizontal locations in external space. Seven healthy human subjects had to assess the spatial fit of a visual stimulus (i.e. a gray-scaled picture of a cartoon dog) and a simultaneously presented auditory stimulus (i.e. a barking sound). Functional magnetic resonance imaging (fMRI) revealed two distinct networks of cortical regions that processed preferentially either spatially congruent or spatially incongruent AV stimuli. Whereas earlier visual areas responded preferentially to incongruent AV stimulation, higher visual areas of the temporal and parietal cortex (left inferior temporal gyrus [ITG], right posterior superior temporal gyrus/sulcus [pSTG/STS], left intra-parietal sulcus [IPS]) and frontal regions (left pre-central gyrus [PreCG], left dorsolateral pre-frontal cortex [DLPFC]) responded preferentially to congruent AV stimulation. A position-resolved analysis revealed three robust cortical representations for each of the four visual stimulus locations in retinotopic visual regions corresponding to the representation of the horizontal meridian in area V1 and at the dorsal and ventral borders between areas V2 and V3. While these regions of interest (ROIs) did not show any significant effect of spatial congruency, we found subregions within ROIs in the right hemisphere that showed an incongruency effect (i.e. an increased fMRI signal during spatially incongruent compared to congruent AV stimulation). We interpret this finding as a correlate of spatially distributed recurrent feedback during mismatch processing: whenever a spatial mismatch is detected in multisensory regions (such as the IPS), processing resources are re-directed to low-level visual areas.

Acoustic Stimulation↗

Abnormally speeded saccades to ipsilesional targets in patients with spatial neglect.

We mapped the distribution of saccadic reaction times (SRTs) in the visual field of patients with spatial neglect in order to characterise the topography of the bias in spatial orientation peculiar to this disorder. LED-generated stimuli were lit randomly in one of four positions (+/-5 degrees , +/-10 degrees , +/-20 degrees , +/-30 degrees ) along the horizontal meridian in blocks of either ipsilesional or contralesional presentations. Patients were asked to move the gaze as quickly as possible from central fixation to target upon its appearance. Unlike control subjects, patients with neglect showed an asymmetric distribution of visuo-motor performance in the two hemifields with an increasing impairment in target detection and saccadic reaction at increasing eccentricities in the contralesional field. In contrast, in the ipsilesional field they showed abnormally speeded SRTs at 5 degrees and 10 degrees , outperforming even healthy subjects. Latency of saccades increased again at more peripheral ipsilesional locations (20 degrees and 30 degrees ) where there was also a tendency for a higher omission rate as compared to control groups. These results indicate that in neglect patients the spatial orientation bias, as witnessed by saccadic performance, specifically affects an off-centred sector of the ipsilesional space, and this is in keeping with evidence from a previous study using a manual RT paradigm. The generality of this phenomenon across different types of motor response suggests that it depends upon abnormal mechanisms of spatial coding interfering with perceptual processing and orienting behaviour.

Adult↗