Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Influence of segmenting fluids on efficiency, crossing point and fluorescence level in real time quantitative PCR.

The two-phase segmented flow approach to the processing and quantitative analysis of biological samples in microdevices offers significant advantages over the single-phase continuous flow methodology. Despite this, little is known about the compatibility of samples and reactants with segmenting fluids, although a number of investigators have reported reduced yield and inhibition of enzymatic reactions depending on the segmenting fluid employed. The current study addresses the compatibility of various segmenting fluids with real time quantitative PCR to understand the physicochemical requirements of this important reaction in biotechnology. The results demonstrate that creating a static segmenting fluid/PCR mix interface has a negligible impact on the reaction efficiency, crossing threshold and end fluorescence levels using a variety of segmenting fluids. The implication is then that the previously reported inhibitory effects are the result of the dynamic motion between the segmenting fluid and the sample in continuously flowing systems. The results presented here are a first step towards understanding the limitations of the segmented flow methodology, which are necessary to bring this approach into mainstream use.

Complex Mixtures↗

A new strategy for exploiting ion exchange in sequential injection analysis: in-line phytic acid separation/determination in foods as an example.

A novel strategy for exploiting ion exchange in sequential injection systems is proposed. The procedure is based on the selection of a defined volume of a resin suspension, which is introduced and packed in the analytical path, establishing a resin mini-column in the system. The passage of a selected sample volume through the resin mini-column leads to the retention of the analyte, while the sample matrix is discarded. The analyte is eluted during the passage of the eluant/reagent by the packed beads, being the analytical signal monitored (absorbance) in the liquid phase. The beads are then aspirated back to the holding coil and directed to a recovery flask, linked at the selection valve; then the system is ready to begin a new cycle. With the proposed strategy, the main characteristics of the sequential injection system are kept as any new artifact is added to the manifold and system reconfiguration is not required. The feasibility of the approach is demonstrated by the phytic acid determination in food samples. For this specific application, AG1-X8 was selected as ion exchanger, and a solution containing Cl- and Fe(III)-salicylate complex was used as eluant and spectrophotometric reagent.

Anion Exchange Resins↗

Analysis of ephedra-alkaloids using sweeping and cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography methods.

Two stacking methods of capillary electrophoresis (CE) were developed for the separation of very dilute solutions of ephedra-alkaloids, namely ephedrine, pseudoephedrine, methylephedrine, methylpseudoephedrine, norephedrine, and norpseudoephedrine. A sweeping method which uses a carrier comprised of phosphoric acid, sodium dodecyl sulfate (SDS), diethylamine and acetonitrile permits the detection of the alkaloids down to the 10(-1) microg/mL level, and the cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) method using phosphoric acid, SDS, and acetronitrile as electrolytes can detect down to the 10(-3) microg/mL level. The former requires the conductance of the sample solution to be adjusted beforehand, and only five peaks were observed, two of which were overlapped. The latter is capable of separating the six alkaloids but has a somewhat poorer reproducibility. Using an optimized injection time, it was found that the more diluted a solution is, the greater the sweeping effect will be. The CSEI-Sweep-MEKC method with a 600 s injection time and a 10(-1) microg/mL solution concentration provides an amplification effect of approximately 10(4). The method is suitable for analyses of dilute herb drug extracts and mouse sera. The effect of buffers on the separation and validation of the methods in this study are also discussed.

Acetonitriles↗

Numerical analysis of an electrokinetic double-focusing injection technique for microchip CE.

The injection techniques in electrophoresis microchips play an important role in the sample-handling process, whose characteristics determine the separation performance achieved, and the shape of a sample plug delivered into the separation channel has a great impact on the high-quality separation performance as well. This paper describes a numerical investigation of different electrokinetic injection techniques to deliver a sample plug within electrophoresis microchips. A novel double-focusing injection system is designed and fabricated, which involves four accessory arm channels in which symmetrical focusing potentials are loaded to form a unique parallel electric field distribution in the intersection of injection channel and separation channel. The parallel electric field effectuates virtual walls to confine the spreading of a sample plug at the intersection and prevents sample leakage into separation channel during the dispensing step. The key features of this technique over other injection techniques are the abilities to generate regular and nondistorted shape of sample plugs and deliver the variable-volume sample plugs by electrokinetic focusing. The detection peak in the proposed injection system is uniform regardless of the position of the detection probe in the separation channel, and the peak resolution is greatly enhanced. Finally, the double-focusing injection technique shows the flexibility in detection position and ensures improved signal sensitivity with good peak resolution due to the delivered high-quality sample plug.

Computer Simulation↗

Effects of EDTA on signal stability during electrochemical detection of acetaminophen.

The use of EDTA in the medium to avoid the passivation of a solid electrode during electrochemical analysis of acetaminophen is presented in this work. The performance of this system was investigated with respect to pH, applied potential and supporting electrolyte concentration. The major advantage in using EDTA in the supporting electrolyte is the significant increase in sensitivity, precision and stability of the measurements, when compared to the system in absence of the chelating agent. The sensitivity increases 5.5 times (21.5 and 3.9 mA l mol(-1) in the presence and the absence of EDTA, respectively), the repeatability (n=20) is 3.5 times better, expressed by within-run-precision of 4.0% for 6.0 x 10(-5) mol l(-1) acetaminophen in the presence of EDTA while, in its absence, the within-run-precision was higher than 14%. Moreover, the system showed excellent stability, allowing more than 120 measurements with no significant changes.

Acetaminophen↗

Diffusion-limited interaction between unfolded polypeptides and the Escherichia coli chaperone SecB.

SecB is a chaperone dedicated to protein translocation in Escherichia coli. SecB binds to a subset of precursor proteins, and targets them in a translocation-competent state to the SecA subunit of the translocase. The nature and kinetics of the interaction of SecB with polypeptides were studied by spectroscopic techniques using the reduced form of bovine pancreatic trypsin inhibitor (BPTI) as a model substrate. Binding of SecB to BPTI resulted in an increase in the fluorescence of the surface-exposed tryptophan residue 36 of SecB. SecB reversibly binds BPTI in stoichiometric amounts. Labeling of BPTI with the fluorophore acrylodan allowed the analysis of the binding reaction at nanomolar concentrations. High-affinity binding (KD of 5.4 nM) of labeled BPTI to SecB resulted in a blue shift of the acrylodan emission maximum and an increase in the fluorescence quantum yield, suggesting that BPTI binds in an apolar environment. Stopped-flow acquisition of rate constants of complex formation between SecB and BPTI yielded a second-order binding rate constant of 5 x 10(9) M-1 s-1, and a dissociation rate constant of 48 s-1. These data demonstrate that in vitro, the association of SecB with polypeptide substrates is limited by the rate of collision. In vivo, SecB binding is selective, and predominantly occurs with nascent polypeptides. Since these chains are not expected to fold into stable structures, SecB association may be governed by "more or less" specific interactions and be limited by the rate of chain elongation rather than the rate of folding.

2-Naphthylamine↗

Characterizing electrospray ionization using atmospheric pressure ion mobility spectrometry.

Reduced flow rate electrospray ionization has been proven to provide improved sensitivity, less background noise, and improved limits of detections for ESI-MS analysis. Miniaturizing the ESI source from conventional electrospray to microelectrospray and further down to nanoelectrospray has resulted in higher and higher sensitivity; however, when effects of flow rate were investigated for atmospheric pressure ESI-IMS using a nanospray emitter, a striking opposite result was observed. The general tendency we observed in ESI-IMS was that higher flow rate offered higher ion signal intensity throughout a variety of conditions investigated. Thus, further efforts were undertaken to rationalize these contradictory results. It is well accepted that decreased flow rate increases both ionization efficiency and transmission efficiency, thus improving ion signal in ESI-MS. However, our study revealed that decreased flow rate results in decreased ion signal because ion transfer is constant, no matter how flow rate changes in ESI-IMS. Since ion transfer is constant in atmospheric pressure ESI-IMS, ionization efficiency can be studied independently, which otherwise is not possible in ESI-MS in which both ionization efficiency and transmission efficiency vary as conditions alter. In this article, we present a systematic study of signal intensity and ionization efficiency at various experimental conditions using ESI-IMS and demonstrate the ionization efficiency as a function of flow rate, analyte concentration, and solvent composition.

Atmospheric Pressure↗

The quantification of potassium using a quartz crystal microbalance.

N,N'-dibenzyl-4,13-diaza-18-crown-6 (A) and bis[(benzo-15-crown-5)-4'-ylmethyl] pimelate (B) were tested as coatings for two piezoelectric crystals for potassium quantification. Both sensors showed stability, reversibility and sensitivity characteristics that allowed their use in quantitative analysis. However, compound A is much more sensitive to potassium than B. Compound A also shows a larger relative sensitivity for potassium with regard to sodium than B. A pharmaceutical sample of known composition was analysed both by an acoustic wave sensor with a crystal coated with compound A and by conductivity. No statistically significant difference in the median of the results was found (alpha = 0.05), although precision is superior for the conductivity methodology. Performance of the sensor in terms of frequency stability and selectivity was improved by the incorporation of PVC, a plasticizer and a lipophilic salt in the coating composition. Limits of detection found for potassium were 1.92 ppm, or 1.75 ppm for a crystal with a frequency decrease due to coating of 2.9 kHz or 3.9 kHz, respectively. Selectivity coefficients (fixed interference 80 ppm) for potassium over Na, Ca, Al, Zn, Mg, and Fe ranged from 0.103 to 0.332.

Flow Injection Analysis↗

Measuring the length of hydrodynamically injected plugs in capillary electrophoresis using the electrical current monitoring.

Although CE is nowadays a worldwide separation technique, it is generally recognized that one of its main limitations is its poor robustness for quantitative analysis. Although this limitation can partially be surpassed using internal standards (ISs), it is well known that to find adequate standards is a very difficult task when too complex mixtures have to be analyzed. In this work, an alternative method to improve quantitation by CE is presented using the electrical current profile monitored during any CE run. Thus, an abrupt step in the current monitoring is observed when a hydrodynamically injected plug of conductivity different from the BGE leaves the capillary under the influence of the EOF. It is demonstrated that under these conditions, the relative amplitude of this step can be used to measure experimentally the injection length. This measure can not only be used for calibration, but also to correct variations of the length injected which is demonstrated to improve significantly the quantitative accuracy and reproducibility of CE. Thus, RSD values for interday quantification (five experiments a day for 5 days) were improved from 10.5 to 4.2%. Moreover, it is also demonstrated that accuracy of quantitative determinations by CE can greatly be improved by using this procedure. The method can also be implemented in other separation techniques where the EOF is used as driving force (e.g., CEC, MEKC or chip-based separations). Advantages and limitations of this approach in comparison to the use of ISs are also discussed.

Calibration↗

Parallel optimization and genotyping of multiple single-nucleotide polymorphism markers by sample pooling approach using cycling-gradient CE with multiple injections.

Increasing importance of single-nucleotide polymorphisms (SNPs) in determination of disease susceptibility or in prediction of therapy response brings attention of many molecular diagnostic laboratories to simple and low-cost SNP genotyping methodologies. We have recently introduced a mutation detection technique based on analysis of homo- and heteroduplex PCR fragments resolved in cycling temperature gradient conditions on a conventional multicapillary-array DNA sequencer. The main advantage of this technique is in its simplicity with no requirement for sample cleanup prior to the analysis. In this report we present a practical application of the technology for genotyping of SNP markers in two separate clinical projects resulting in a combined set of 44 markers screened in over 500 patients. Initially, a design of PCR primers and conditions was performed for each SNP marker. Then, optimization of CE running conditions (limited just to the proper selection of temperature cycling) was performed on pools of 20 DNA samples to increase the probability of having each of the two allele types represented in the sample. After selecting the optimum conditions, screening of markers in patients was performed using a multiple-injection approach for further acceleration of the sample throughput. The rate of successful optimization of experimental conditions without any pre-selection based on the SNP sequence or melting characteristics was 80% from the initial SNP marker candidates. By studying the failed markers, we attempt to identify critical factors enabling successful typing. The presented technique is very useful for low to medium sized SNP genotyping projects mostly applied in pharmacogenomic research as well as in clinical diagnostics. The main advantages include low cost, simple setup and validation of SNP markers.

Electrophoresis, Capillary↗

Fast sequential injection determination of benzo[A]pyrene using variable angle fluorescence with on-line solid-phase extraction.

A methodology for the analysis of drinking water for one of the most potent carcinogenic agents known; benzo[a]pyrene (BaP), in the presence of other interfering PAHs is presented. The methodology described is based on the sequential injection analysis of the sample on to a microcolumn (containing 5 mg of C18) where extraction and preconcentration of BaP takes place, followed by elution of BaP with 1 ml of 1,4-dioxane and subsequent detection by using variable angle fluorescence. The advantages of the method include the small amount of stationary phase employed together with the possibility of re-using the phase in order to carry out a large number of injections without the need for column re-packing. Also noteworthy is the small volume of 1,4-dioxane used to elute the BaP retained on the column and the small sample volumes required (9-10 ml) for achieving detection limits at the ng l-1 level. Thus, a methodology for BaP determination is obtained which complies with the requirements of the 98/83/EC Directive which fixes a maximum admissible concentration for this pollutant in waters for public consumption of 10 ng l-1. The variable angle spectra obtained are further processed by means of the multiple linear regression technique. The detection limit for BaP is 2.5 ng l-1, and the linear range is between 7.5 and 280 ng l-1.

Autoanalysis↗

On-line multi-analyzer monitoring of biomass, glucose and acetate for growth rate control of a Vibrio cholerae fed-batch cultivation.

In situ near-infrared (NIR) spectroscopy and in-line electronic nose (EN) mapping were used to monitor and control a cholera-toxin producing Vibrio cholerae fed-batch cultivation carried out with a laboratory method as well as with a production method. Prediction models for biomass, glucose and acetate using NIR spectroscopy were developed based on spectral identification and partial-least squares (PLS) regression resulting in high correlation to reference data (standard errors of prediction for biomass, glucose and acetate were 0.20 gl(-1), 0.26 gl(-1) and 0.28 gl(-1)). A compensation algorithm for aerated bioreactor disturbances was integrated in the model computation, which in particular improved the prediction by the biomass model. First, the NIR data were applied together with EN in-line data selected by principal component analysis (PCA) for generating a trajectory representation of the fed-batch cultivation. A correlation between the culture progression and EN signals was demonstrated, which proved to be beneficial in monitoring the culture quality. It was shown that a deviation from a normal cultivation behavior could easily be recognized and that the trajectory was able to alarm a bacterial contamination. Second, the NIR data indicated the potential of predicting the concentration of formed cholera toxin with a model prediction error of 0.020 gl(-1). Third, the on-line biomass prediction based on the NIR model was used to control the overflow metabolism acetate formation of the V. cholerae culture. The controller compared actual specific growth rate as estimated from the prediction with the critical acetate formation growth rate, and from that difference adjusted the glucose feed rate.

Acetates↗

Homogeneous fluorescent derivatization of large proteins.

A method of homogeneously derivatizing large proteins for highly sensitive analysis is described. Homogeneity of the derivative was realized by tagging all the free amino groups of proteins. With this method, alpha-chymotrypsinogen A, ovalbumin and bovine serum albumin were derivatized with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC). Prior to the derivatization, all the proteins were reduced and alkylated. After reacting the resulting unfolded proteins with excessive amounts of AQC, the samples were analyzed with matrix assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) to determine the derivatization degree. The results indicated that all three proteins had been, or had almost been, fully derivatized. HPLC and CE were used for characterizing these protein derivatives. Under the optimized fluorescence detection conditions, the detectability of the tagged proteins was 2400-6200 times better than that detected at UV 280 nm, 170-300 times better than detected at UV 214 nm, and 150-420 times better than measured with their native fluorescence.

Electrophoresis, Capillary↗

Evaluation of the total antioxidant capacity by using a multipumping flow system with chemiluminescent detection.

An automated flow-based procedure for assessment of total antioxidant capacity was developed. It involved a multipumping flow system, a recent approach to flow analysis, and exploited the ability of selected compounds to inhibit the chemiluminescence reactions of luminol or lucigenin with hydrogen peroxide. The system included several discretely actuated solenoid micropumps as the only active components of the flow manifold. This enabled the reproducible insertion and efficient mixing of very low volumes of sample and reagents as well as the transportation of the sample zone toward a flow-through luminometer, where the chemiluminometric response was monitored. With luminol as the chemiluminogenic reagent, linearity of the analytical curves was noted up to 3.2x10(-4), 1.1x10(-3), and 8.8x10(-8) molL-1 for Trolox, ascorbic acid, and resveratrol, respectively. With lucigenin, linear calibration plots up to 2x10(-5) molL-1 of Trolox and 5.7x10(-5)molL-1 of ascorbic acid were obtained. As favorable analytical figures of merit, the measurement precision (RSD typically between 0.2 and 2.0%, n=10), low operational costs, low reagent consumption, sampling rate (160 and 70 h-1), and versatility should be highlighted. The proposed system can be used in distinct analytical circumstances without requiring physical reconfiguration.

Antioxidants↗

Analysis and modeling of fixed bed column operations on As(V) removal by adsorption onto iron oxide-coated cement (IOCC).

Fixed-bed column studies were undertaken to evaluate the performance of iron oxide-coated cement (IOCC) in removing As(V), from aqueous environment, under varying operating conditions. Investigations revealed IOCC to be a very efficient media for the removal of As(V) from water. The Bohart and Adams sorption model was employed to determine characteristic parameters such as depth of exchange zone, time required for exchange zone to move its own height, adsorption rate, and adsorption capacity, useful for process design. The IOCC media effectively removed As(V) from a 2 mg/L solution with a maximum adsorption capacity of 505.3 mg/L. Predicted data points obtained using a Freundlich isotherm model were compared against experimental data points determined in the dynamic process. The effects of important design parameters such as flow rate and influent concentration on the As(V) breakthrough curves were also investigated. The bed depth service time (BDST) model was extended to the prediction of service times of columns operated at different flow rates and influent concentrations and these predicted values were compared with the experimental values. The columns were regenerated by eluting the bound As(V) with 10% NaOH after the adsorption studies.

Adsorption↗

Analysis of zearalenone in cereal and Swine feed samples using an automated flow-through immunosensor.

The development of a sensitive flow-though immunosensor for the analysis of the mycotoxin zearalenone in cereal samples is described. The sensor was completely automated and was based on a direct competitive immunosorbent assay and fluorescence detection. The mycotoxin competes with a horseradish-peroxidase-labeled derivative for the binding sites of a rabbit polyclonal antibody. Control pore glass covalently bound to Prot A was used for the oriented immobilization of the antibody-antigen immunocomplexes. The immunosensor shows an IC(50) value of 0.087 ng mL(-1) (RSD = 2.8%, n = 6) and a dynamic range from 0.019 to 0.422 ng mL(-1). The limit of detection (90% of blank signal) of 0.007 ng mL(-1) (RSD = 3.9%, n = 3) is lower than previously published methods. Corn, wheat, and swine feed samples have been analyzed with the device after extraction of the analyte using accelerated solvent extraction (ASE). The immunosensor has been validated using a corn certificate reference material and HPLC with fluorescence detection.

Animal Feed↗

Development of an element-selective monitoring system for adsorbable organic halogens (AOX) with plasma emission spectrometric detection for quasi-continuous waste-water analysis.

An automated quasi-continuously-operating monitor has been developed for element-selective analysis of adsorbable organic halogens (AOX) in water. After extensive optimization the automatic method was applied to the analysis of standard solutions and real waste water samples to prove its analytical applicability. The new instrument is based on the element-selective analysis of halogens by means of a spectroscopic detection system consisting of a microwave-induced helium plasma excitation source (TM010-type; developed in this laboratory) and the plasma emission detector (PED) which operates with oscillating narrow-band interference filters. After enriching the organic components on activated charcoal and pyrolysis in an oxygen stream at 950 degrees C, in accordance with DIN/EN 38409,H14/1485, interfering CO2 and H2O gas generated during combustion is removed from the analytes in the so-called ELSA-system (element-selective AOX-analyzer). For focused injection into the plasma excitation source the analytes (hydrogen halides) are trapped in a deactivated fused silica capillary at -180 degrees C; this is followed by identification and quantification on the basis of element-specific emission of radiation in the VIS and NIR-region (chlorine 837.6 nm, fluorine 685.6 nm). Bromine and iodine could not be detected with satisfactory inter-element selectivity, because of spectral interferences caused by matrix elements, and so results from the respective single-element investigations for determination of AOBr and AOI are not presented. The procedure has been validated and the analytical performance has been examined by calibration with p-chlorophenol and p-fluorophenol. The limit of detection was 1.1 microg (absolute) for chlorine and 6.6 microg (absolute) for fluorine.

Flow Injection Analysis↗

On-line stoichiometry and identification of metabolic state under dynamic process conditions.

A method for the on-line calculation of conversion rates and yield coefficients under dynamic process conditions was developed. The method is based on cumulated mass balances using a moving average method. Elemental balances were used to test the measured cumulated quantities for gross errors and inappropriate stoichiometry definition followed by data reconciliation and estimation of non-measured conversion rates, using a bioprocess set-up including multiple on-line analysis techniques. The quantitative potential of the proposed method is demonstrated by executing transient experiments in aerobic cultures of Saccharomyces cerevisiae on glucose. Rates and yield coefficients could be consistently quantified in shift-up, shift-down, and accelerostat experiments. The method shows the capability to describe quantitatively transient changes in metabolism including uncoupling of catabolism and anabolism, also for the case when multiple components of metabolism are not measured. The validity of the experiment can be evaluated on-line. Additionally, the method detects with high sensitivity inappropriate stoichiometry definition, such as a change in state of metabolism. It was shown that concentration values can be misleading for the identification of the metabolic state. In contrast, the proposed method provides a clear picture of the metabolic state and new physiological regulations could be revealed. Hence, the novelty of the proposed method is the on-line availability of consistent stoichiometric coefficients allowing a significant speed up in strain characterization and bioprocess development using minimal knowledge of the metabolism. Additionally, it opens up the use of transient experiments for physiological studies.

Bioreactors↗