Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DISINFECTANTS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

[Disinfection of sewage waters from rendering plants with peracetic acid].

In our experiments, peracetic acid--known in commerce as "Wolfasteril" was tested as a new and efficient disinfectant to disinfect sewage waters from rendering plants. Peracetic acid was used in experiments in concentration of 0.1 to 1.0% for 30 sec. to 60 min. As a comparative agent, 5% chloramine was used. Results obtained in preliminary and main experiments proved that peracetic acid is fully appropriate to disinfect biologically cleaned sewage waters in rendering plants. Sewage waters supplying the main stream has to pass mostly a short section after having left the water clarifier. Consequently, the concentration of 1% peracetic acid acting for 30 sec. is the optimum one. The recommendation of this application norm for peracetic acid in water clarifiers from rendering plants being at least suitable in controlling disasters.

Acetates↗

Chlorate as an inorganic disinfection by product in swimming pools.

Chlorate and chlorite concentrations were determined in water samples taken from 33 swimming pools. In the pools under investigation, disinfection of the water is carried out either by gaseous chlorine (n = 14) or hypochlorite solution in conjunction with flocculation and sand filtration. A number of the pools also use ozone treatment to augment the disinfection process. Chlorite was not detectable in any of the samples (detection limit 1 mg/l). High concentrations of chlorate were detected in samples from a number of the pools; in one case as high as 40 mg/l. Higher chlorate concentrations were found to be associated with those pools using hypochlorite solution as a disinfecting agent. In contrast, relatively low chlorate concentrations were found in pools treated with gaseous chlorine. In order to elucidate any relationship between the chlorate content of pool water and that of the respective hypochlorite stock solution, chlorate and bromate concentrations were determined in the hypochlorite stock solutions of nine pools. Bromate concentration in the stock solutions were not found to exceed 1.2 g/l, chlorate was measured in concentrations of up to 44.5 g/l. The additional use of ozone as part of the water purification process appears to have no significant influence on chlorate concentration. Chlorate has no bactericidal properties and does not interfere with the measurement of certain parameters relevant to hygiene in swimming pools such as free and combined chlorine, pH or redox potential. At present, the effects of high chlorate concentrations in swimming pool water are unclear. Our initial investigations indicate that chlorate has no cytotoxic (Neutral-Red assay) or irritating properties (HET-CAM assay). However, both chlorate and chlorite are known to interfere with the haematopoetic system. In Germany, the MCL for chlorite in drinking water is 0.2 mg/l. It is therefore strongly recommended that measures should be taken to reduce chlorate concentrations in swimming pool water.

Animals↗

Something in the water? A health impact assessment of disinfection by-products in New Zealand.

Disinfection by-products (DBP) are a large group of halogenated chemicals formed by the reaction of disinfectant agents with naturally-occurring organic substances in water. Numerous studies have found associations between DBP and some cancers and adverse reproductive outcomes. For both cancer and birth defects the relative risk associated with exposure to DBP is about 1.5. About 66% of New Zealanders, or 2.4 million people, use chlorinated water supplies and are exposed to DBP. New Zealand's unique combination of flora, climate and geology will create unique mixtures of DBP but little detailed information is available on the level or composition of DBP in New Zealand. The population attributable risk per cent, for cancers and birth defects in New Zealand, is about 25%. In other words, a quarter of all bladder, colon and rectal cancers and birth defects may be preventable by reducing DBP exposure. This is equal to 329 preventable cancer deaths in 1995 and 94 preventable birth defects in 1996. DBP exposure can be reduced without compromising microbiological safety of water supplies. The health effects of DBPs must be weighed against the cost of DBP reduction and not against the potential water borne disease prevented by disinfection. Some aspects of New Zealand's water supplies and population provide a unique opportunity to undertake research. Further research is needed on the occurrence of DBPs and their health consequences in order to undertake a properly informed risk assessment.

Abnormalities, Drug-Induced↗

New connection method for isolating and disinfecting intraluminal path during peritoneal dialysis solution-exchange procedures.

Microbiological data have been collected on the performance of a new method of isolating and disinfecting the intraluminal path at the connect/disconnect site of a peritoneal dialysis (PD)-exchange pathway. High-temperature moist-heat (HTMH) disinfection is accomplished by a new device that uses microwave energy to heat the solution contained in the pressure-tight inner lumen of PD connector pairs between the transfer-set connector-clamp and the bag-connector break-away seal. An 85 degrees C (S.D. = 2.4 degrees C, n = 10) rise in solution temperature is seen in 12 seconds, thus yielding temperatures under pressure well over 100 degrees C with starting temperatures of 25 degrees C. Connector pairs were prepared by inoculation of a solution suspension containing at least 10(6) colony-forming units (CFU) of a test micro-organism. Approximately 0.4 mL of solution was contained within the mated connector pair. Using standard D-value determination methods, data were obtained for surviving organisms versus five exposure times and a positive control to obtain a population reduction curve. Four micro-organisms (S. epidermidis, P. aeruginosa, C. albicans, and A. niger) recognized to be among the most prevalent or problematic in causing peritonitis were tested. After microwave heating, the treated solution was aseptically withdrawn from the connector pair using a needle and syringe, plated in growth media, and incubated. Population counts of CFUs after incubation were used to establish survival curves. Results showed a tenfold population reduction in less than 3 seconds for all organisms tested. A 30-second cycle time safely achieves a > 10(8) population-reduction for bacteria and yeast organisms, and a > 10(7) population reduction for fungi. One potential benefit of using this new intraluminal disinfection method is that it may help reduce peritonitis resulting from the even more problematic pathogens such as the gram-negative bacteria and fungal organisms.

Bacteria↗

[Measures for the disposal of non-regulated alternative medical wastes--effects of disinfectants on activated sludges].

Effects on activated sludges of several disinfectants with strong and wide antimicrobial ability, were investigated using an oxygen up-take method. As a results, at the maximal non-reactive concentration of disinfectants, hexachlorophene has estimated value of 6 mg/l and shows the highest toxicity against activated sludges. At the lethal concentration of 50%, the toxicity of triclosan is the strongest disinfectant.

Bacteria, Aerobic↗

Disinfection with flash lamps.

The analysis of published and new data on a pulsed disinfection is presented. It allows the conclusion that the pulsed disinfection mechanism includes both germicidal action of UVC light and a rupture of bacteria due to thermal stress, caused primarily by all UV components of the light pulse. The role of simultaneous cooling and heating of bacteria during a flash lamp pulse has been estimated and a direct detection of such a mechanism is proposed. It is suggested that an optimum pulsed light source for disinfection must have as much percentile content of a broad UV spectrum and a high peak power as is technically justified. Two new applications for pharmaceutics and medicine are suggested.

Disinfection↗

[Irritating effect and dermal toxicity of virkon, a disinfectant widely used in Poland].

The aim of the study was to define the threshold irritating effect of Virkon, a disinfectant widely used in Poland, on the rabbit's skin and eye, and its dermal toxicity in single exposure. The studies were carried out according to the OECD guidelines, modified by Krysiak. A 10% aqueous solution of Virkon in the conditions of multiple open exposure was defined as the threshold concentration evoking small inflammatory reaction. After a single administration of Virkon in aqueous solutions into the rabbit's eye, the value of sensitising effect index was 1.5 for 1% solution of the disinfectant in question which indicates weak inflammatory reaction. The study of dermal toxicity in a single exposure revealed neither animal death nor morphological changes in internal organs which suggests non-cutaneous absorption of Virkon. The present study may provide the basis for assessing dermatological changes in people exposed to disinfectants.

Animals↗

[Problems of disinfection and decontamination in the biological protection and prevention of contagious diseases].

The problems of biological protection of the general population and military staff against biological hazard sources, primarily against biological terrorism and military threat underlie works on the design of new disinfectants having a universal spectrum of antimicrobial action and less ecological hazard than currently available ones. Elimination of biological hazard require effective chemical disinfectants that can completely inactivate microbes of unknown etiology as rapidly as possible and that cause the minimum damage to environmental objects. The disinfectant PFK of various modifications is evaluated in terms of the requirements of that ecological and chemical concept aimed at testing chemicals entering the environment.

Decontamination↗

[Measurement of formaldehyde in disinfectant with spectrophotometry].

Formaldehyde in disinfectant was measured by acetylacetone spectrophotometry. The regression equation was linear when the formaldehyde concentration was smaller than 10 micrograms/ml. The detection limit was 0.08 microgram/ml. The accuracy was less than 3.9% and the recovery varied between 100.2%-108.2% for formaldehyde disinfectant with different concentration, which was similar to titrimetry. It was demonstrated that the method was simple, reproducible, sensitive, precise and accurate, making it important for assay of formaldehyde in disinfectant when disturbance caused titrimetry unavailable.

Disinfectants↗

Low-power microwave disinfection of soft contact lenses.

PURPOSE: To evaluate the effectiveness of low-power microwave irradiation on the disinfection of contaminated contact lenses. METHODS: We infected 24 soft contact lenses with Staphylococcus epidermidis, Staphylococcus aureus, and Pseudomonas aeruginosa. Each contact lens was placed into a vial containing 10 mL of contaminated, non-preserved saline. Each vial was then exposed to 2, 4, 6, 9, 12, 15, or 18 minutes of microwave irradiation in an oven (2,450 MHz 600W) set at 10% power. RESULTS: We found all contact lenses to be disinfected after 15 minutes of exposure. All lenses remained hydrated and revealed no apparent damage when examined under the slit-lamp biomicroscope. CONCLUSIONS: Low level microwaving in a home microwave oven can result in effective and non-damaging disinfection of soft contact lenses.

Contact Lenses, Hydrophilic↗

Responding to fecal accidents in disinfected swimming venues.

These recommendations are solely for management of fecal accidents in disinfected recreational water venues. The recommendations do not address use of other nonchlorine disinfectants because there is limited pathogen inactivation data for many of these compounds. Because improper handling of chlorinated disinfectants could cause injury, appropriate occupational safety and health requirements should be followed.

Chlorine↗

[Effectiveness of environmental disinfection with formalin aerosol].

The effectiveness was tested of preventive disinfection of pig-fattening houses with formalin, applied as aerosol with the Swingfog SN 100 apparatus. The effectiveness of this treatment was evaluated according to the proportion of smears containing lactoso-positive micro-organisms, expressed as a percentage of the total number of smears, and according to the reduction of contamination with E. coli and St. aureus on wooden or aluminium carriers. The effectiveness was found to be good and the treatment is recommended as suitable for the preventive disinfection of stables. However, the following procedure should be strictly observed: Before disinfection the stables must be thoroughly mechanically cleansed, dried, and well closed to be air-tight. The air temperature in these premises should not be lower than 12 degrees C. Formalin (with a minimum content of 40% of formaldehyde) should be applied at a rate of at least 10 ml per 1 m3 of space and the agent should be diluted with water at 1 : 1 ratio prior to use. The aerosol should be produced by the Swingfog SN 100 generator, adjusted to apply about 40 1 of the solution per hour. The maximum space treated from one place should be limited to 500 m3. The exposure time should be at least 16 hours.

Aerosols↗

Performance of the full-scale biological nutrient removal plant at Noosa in Queensland, Australia: nutrient removal and disinfection.

Stringent effluent quality guidelines are progressively implemented in coastal and sensitive areas in Australia. Biological Nutrient Removal (BNR) plants are becoming a standard often including a tertiary treatment for disinfection. The BNR plant in Noosa - Queensland is designed to produce a treated effluent with less than 5 mg/l of BOD5, 5 mg/l of total nitrogen, 1 mg/l of total phosphorus, 5 mg/l of suspended solids and total coliforms of less than 10/100 ml. A flexible multi-stage biological process with a prefermentation stage, followed by sand filtration and UV disinfection was implemented to achieve this level of treatment. Acetic acid is added for phosphorus removal because: i) the volatile fatty acids (VFA) concentration in raw wastewater varies a lot, and ii) the prefermenter had to be turned off due to odor problems on the primary sedimentation tanks. An endogenous anoxic zone was added to the process to further reduce the nitrate concentration. This resulted in some secondary P-release events, a situation that happens when low nitrate and low phosphorus objectives are targeted. Long-term performance data and specific results on nitrogen removal and disinfection are presented in this paper.

Acetic Acid↗

[Evaluation of efficacy of selected antiseptics for hands disinfection before surgical procedures].

The most important in surgical hands washing and disinfections is long-term and effective reduction of bacteria number. The aim of this study was to compare the efficiency of some antiseptic fluids used for surgical hands disinfection's (AHD 2000, Biotensid, Manopronto and Medi-Scrub PVP Iodine). 62 doctors and surgical nurses were examined. The material for the bacteriological examination was collected before and after hands disinfection's. The bacterial flora reduction have been presented as a percent and a logarithmic reduction ratio. All estimated antiseptic fluids were very potent and provided prolonged efficiency when the operation team complied with orders of hands washing.

Anti-Infective Agents, Local↗

[Thoughts upon the construction of requirements of disinfection procedures concerning contaminated hands - an analysis (author's transl)].

The construction of detailed test methods for the evaluation of disinfection procedures has primarily to be based upon requirements which have to be formulated in advance. A recently proposed test model is being discussed on the basis of 5 conceivable formulations of possible requirements. Essentially, they may be allotted to two types: the one implies the comparison of the disinfection procedure to be tested as against an hypothetical procedure. The other makes use of the simple comparison with a concrete standard procedure and is preferable to the first possibility for several reasons. The presented, mathematical formulations of the structure describing the proposed model represents a first approximation in order to permit the comparison of disinfection effects on the hands under assistance of probabilistic methods and eliminating other effects inherent ot a test method.

Disinfection↗

[Hospital hygiene and disinfectants: experience in a teaching hospital].

A survey was conducted during March-July 1999 to assess and identify the disinfectants and chemical sterilants employed in a teaching hospital of Roma. The purposes were studying the problems of safety in the use also, and the treatment like waste of disinfectants and chemical sterilants. Were collected the data from 61% of 39 Department/Institutes of the whole hospital. A total of 635 records were examined, and 40 different active ingredients of 110 commercial forms were identified. This study was conducted by a survey chart. Data collected outline that to minimize the risk for nursing staff, workers and the patients a modern hospital staff should prepare a handbook that can explain the concentrations and correct use for various disinfectants and chemical sterilants that was choose and employed.

Disinfectants↗

Antibacterial efficacy of disinfectants against some gramnegative bacteria.

The antibacterial effect of 11 new commercially manufactured disinfectants on clinical isolates of Salmonella typhimurium DT104, Serratia marcescens and Pseudomonas aeruginosa was studied. The substances tested represented six pure quaternary ammonium substances (QAS) and five QAS combined with other ingredients. The antibacterial efficacy was characterized by influencing the growth of bacterial cells expressed by MIC and ED50 values. The disinfectants are divided into three groups according to their efficacy. The antibacterial efficacy of disinfectants on S. typhimurium DT104 in the study is the highest in comparison with S. marcescens and P. aeruginosa strains. The highest inhibition of growth was caused by Diesen forte on S. typhimurium DT 104 and by Benzalkonium chloride on both S. marcescens and P. aeruginosa strains.

Disinfectants↗