Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DECELERATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Responses of neonates to parents' and others' voices.

Infants stimulated with 8-s recordings of speech and voices reading numbers showed a discrimination between their own mothers' and alien voices. In general, the infants' heart rates rose more in response to their mothers' than to an alien voice. However, infants tested less than 24 h after birth responded with significant heart rate deceleration to the mother's spontaneous speech and to the mother reading numbers. Response to the father's voice was also deceleration but to all alien voices was acceleration. Older infants' responses also tended to be acceleratory to most stimuli. Results support the suggestion that sounds which are repeatedly experienced before birth (especially the mother's voice) become familiar to the fetus so that the neonate responds selectively by orienting to them during the first few hours after birth.

Arousal↗

Fetal cardiac and motor responses to octave-band noises as a function of central frequency, intensity and heart rate variability.

Accelerative and decelerative cardiac responses and motor responses (leg movements) of 37-40 weeks (G.A.) fetuses are analyzed as a function of the frequency of three octave-band noises (respectively centered at 500 Hz, 2000 Hz and 5000 Hz) and of their intensity level (100, 105, 110 dB SPL, ex utero), during high (HV) and low (LV) heart rate (HR) variability pattern states. In both states, increasing the frequency and/or the intensity of the acoustic stimulation: (i) increases the ratios and amplitudes of accelerations, and the motor response ratios, (ii) reduces deceleration ratios and motor response latencies. Cardiac and motor reactiveness are higher in HV than in LV with acceleration ratios always greater than motor ones. However, when a high intensity and/or frequency is used, the reactiveness differences between states disappears. Low intensity and/or frequency stimulation levels induce a majority of decelerations.

Acoustic Stimulation↗

Demonstration of restrictive ventricular physiology by Doppler echocardiography.

In patients with restriction of cardiac filling of various origins, cardiac catheterization has been traditionally used as part of the diagnostic evaluation to verify the presence of restrictive/constrictive hemodynamics. In an attempt to determine whether this "restrictive" physiology could be demonstrated noninvasively, 14 patients who had a history, physical examination, two-dimensional echocardiogram and catheterization data compatible with a restrictive myocardial process were studied with pulsed wave Doppler ultrasound. Forty normal subjects served as a control group. The Doppler ultrasound evaluation included measurement of peak mitral and tricuspid flow velocities and flow velocity integrals, mitral and tricuspid deceleration times and central venous flow patterns during apnea and inspiration. The flow velocity recordings across the mitral and tricuspid valves in patients manifesting restriction were markedly different from those in normal subjects, showing shortened deceleration times across both valves, which indicated both an abrupt premature cessation of ventricular filling and the presence of a diastolic dip-plateau contour in ventricular pressure recordings. In addition, abnormal central venous flow velocity reversals with inspiration and diastolic mitral and tricuspid regurgitation were frequently observed, also suggesting the reduced myocardial compliance characteristic of a restrictive myocardial process.

Adult↗

Doppler echocardiographic observations during percutaneous aortic balloon valvuloplasty.

To evaluate the hemodynamic changes occurring with percutaneous aortic balloon valvuloplasty for aortic stenosis, Doppler echocardiography was performed during the procedure in 16 patients. During balloon inflation, peak velocity and ejection time of the aortic valve systolic signals increased (26 and 30%, respectively; p less than 0.001). Aortic regurgitation deceleration time decreased from 1,337 to 625 ms (p less than 0.001). In three patients, aortic regurgitation stopped before end-diastole; in four patients, end-diastole forward flow across the aortic valve was documented. The deceleration time of the mitral valve inflow signal decreased from 303 to 194 ms (p less than 0.001) during balloon inflation, concurrently with an increase in left ventricular diastolic pressure. Mitral regurgitation signals became more prominent during inflation in 10 patients. Changes that occur during balloon inflation in the aortic valve include progressive left ventricular outflow obstruction, equalization of diastolic aortic and left ventricular pressures and changes in diastolic compliance.

Aged↗

Reduction of left ventricular preload by lower body negative pressure alters Doppler transmitral filling patterns.

The objective of this study was to evaluate the effect of alterations in preload induced by lower body negative pressure on Doppler transmitral filling patterns. Echocardiograms and Doppler recordings were performed in 18 normal young men (aged 23 to 32 years) during various levels of lower body negative pressure (0, -20 and -50 mm Hg). Lower body negative pressure induced a reduction in diastolic velocity integral (from 12.17 +/- 0.79 to 8.42 +/- 0.71 cm, p = 0.0067) and consequently left ventricular diastolic diameter (from 5.11 +/- 0.09 to 4.45 +/- 0.1 cm, p less than 0.0001). There was a significant reflex increase in heart rate from 59.9 +/- 1.9 to 77.1 +/- 2.4 beats/min (p less than 0.0001), but blood pressure was unchanged. This reduction in preload altered Doppler transmittral filling patterns as follows: 1) peak early velocity (E) decreased from 59.2 +/- 3.8 to 39.1 +/- 1.7 cm/s (p less than 0.0001); 2) atrial filing velocity (A) was unchanged (35.58 +/- 1.5 to 33.52 +/- 1.4 cm/s, p = 0.517); 3) E/A ratio decreased from 1.7 +/- 0.13 to 1.19 +/- 0.08 (p = 0.0087); 4) mean acceleration (from 482 +/- 37 to 390 +/- 27 cm/s2, p = 0.03) and mean deceleration (from 327 +/- 31 to 169 +/- 21 cm/s2, p less than 0.001) of the early filling wave were significantly reduced; and 5) peak acceleration (from 907 +/- 42 to 829 +/- 29 cm/s2) and peak deceleration (from 771 +/- 94 to 547 +/- 76 cm/s2) also decreased, but not significantly.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Serial Doppler echocardiographic follow-up of left ventricular diastolic function in cardiac amyloidosis.

A spectrum of left ventricular diastolic filling abnormalities noted on Doppler echocardiography has been demonstrated in patients with cardiac amyloidosis. To determine how these filling abnormalities evolve over time and the significance of any change, serial pulsed wave Doppler studies of left ventricular inflow were performed over 12.6 +/- 4.9 months in 41 consecutive patients (36 men and 15 women, mean age 59 +/- 11 years) with typical two-dimensional echocardiographic features of cardiac involvement. The measurements were peak left ventricular inflow in early diastole (E) and atrial contraction (A) velocities, E/A ratio, deceleration time and isovolumetric relaxation time. Patients were classified by mean left ventricular wall thickness into an early group (less than 15 mm) of 24 patients and an advanced group (greater than or equal to 15 mm) of 17 patients. The total group showed an increased E/A ratio (1.7 +/- 0.9 versus 1.4 +/- 0.9, p = 0.009) and decreased deceleration time (164 +/- 57 versus 174 +/- 51 ms, p = 0.11) at follow-up compared with baseline study. The early group showed significant changes in the E/A ratio (1.6 +/- 1.0 versus 1.2 +/- 0.7, p = 0.001) between the two studies. Seven patients (29%) in the early group showed a change from an abnormal relaxation or "normal" pattern to one of restriction, coincident with increased symptoms in six of these patients. Fifteen (88%) of the 17 patients in the advanced group did not show significant changes in the measures during the follow-up study, but these patients already showed a restrictive pattern.(ABSTRACT TRUNCATED AT 250 WORDS)

Amyloidosis↗

Left ventricular diastolic filling abnormalities identified by Doppler echocardiography in asymptomatic patients with sickle cell anemia.

To determine whether left ventricular diastolic abnormalities are an early feature of sickle cell anemia, indexes of diastolic filling were obtained with pulsed Doppler echocardiography in 30 consecutive patients with this disease (mean age 29 years; range 19 to 39) who had not experienced symptoms of heart failure and had normal left ventricular systolic function. Data were compared with those in 30 normal control subjects of similar ages. Seventeen (57%) of the 30 patients with sickle cell anemia had evidence of abnormal left ventricular diastolic filling. Six of these 17 patients had a Doppler pattern consistent with "restrictive" filling, characterized by reduced early diastolic deceleration time (less than 110 ms) or an increased rate of decline of early flow velocity (EF slope greater than 7.4 m/s2), or both, as well as decreased late diastolic velocity-time integral (2.6 +/- 0.7 vs. 3.4 +/- 0.8 cm in normal subjects; p less than 0.05). Another 11 patients showed a Doppler waveform consistent with impaired relaxation, characterized by prolonged deceleration time (greater than 166 ms) or reduced EF slope (less than 3.8 m/s2), as well as increased late diastolic velocity-time integral (4.0 +/- 0.5 vs. 3.4 +/- 0.8 cm in normal subjects; p = 0.03). This Doppler echocardiographic analysis demonstrates that left ventricular diastolic filling patterns are altered in patients with sickle cell anemia and that these diastolic abnormalities may be present in the absence of symptoms of heart failure. These abnormal patterns suggest an intrinsic myocardial abnormality in patients with sickle anemia and may prove to be early markers of cardiac disease.

Adult↗

Hemodynamic correlates of the third heart sound during the evolution of chronic heart failure.

OBJECTIVES: The purpose of this study was to examine the temporal relation between the development of a third heart sound during the course of evolving heart failure and associated hemodynamic abnormalities. BACKGROUND: Although various theories have been proposed to explain the origin of the third heart sound, the exact origin of this sound remains unknown. METHODS: Studies were performed in seven dogs in which heart failure was produced by multiple sequential intracoronary micro-embolizations. Hemodynamic studies including ventriculography, pulsed wave Doppler echocardiography and intracardiac phonocardiography were performed at baseline, at the time at third heart sound was first heard and at 6 and 24 weeks after onset of the third heart sound. RESULTS: All dogs developed a third heart sound at 9 +/- 2 weeks after the initial embolization. The onset of the sound was accompanied by an increase in left ventricular chamber stiffness relative to the baseline value (0.25 +/- 0.03 vs. 0.14 +/- 0.01 mm Hg/ml) (p < 0.05) and mean deceleration of early mitral inflow velocity (1,040 +/- 90 vs. 590 +/- 40 cm/s per s) (p < 0.05). CONCLUSIONS: These data indicate that the onset of a third heart sound during the course of evolving heart failure occurs coincident with the development of increased left ventricular chamber stiffness and the manifestation of rapid deceleration of early mitral inflow velocity. These findings are consistent with a myocardial vibratory origin of this sound.

Animals↗

Mechanisms of hemolysis with mitral prosthetic regurgitation. Study using transesophageal echocardiography and fluid dynamic simulation.

OBJECTIVES: The aims of this study were to define the hydrodynamic mechanisms involved in the occurrence of hemolysis in prosthetic mitral valve regurgitation and to reproduce them in a numeric simulation model in order to estimate peak shear stress. BACKGROUND: Although in vitro studies have demonstrated that shear stresses > 3,000 dynes/cm2 are associated with significant erythrocyte destruction, it is not known whether these values can occur in vivo in conditions of abnormal prosthetic regurgitant flow. METHODS: We studied 27 patients undergoing reoperation for significant mitral prosthetic regurgitation, 16 with and 11 without hemolysis. We classified the origin and geometry of the regurgitant jets by using transesophageal echocardiography. By using the physical and morphologic characteristics defined, several hydrodynamic patterns were simulated numerically to determine shear rates. RESULTS: Eight (50%) of the 16 patients with hemolysis had paravalvular leaks and the other 8 had a jet with central origin, in contrast to 2 (18%) and 9 (82%), respectively, of the 11 patients without hemolysis (p = 0.12, power 0.38). Patients with hemolysis had patterns of flow fragmentation (n = 2), collision (n = 11) or rapid acceleration (n = 3), whereas those without hemolysis had either free jets (n = 7) or slow deceleration (n = 4) (p < 0.001, power 0.99). Numeric simulation demonstrated peak shear rates of 6,000, 4,500, 4,500, 925 and 950 dynes/cm2 in these five models, respectively. CONCLUSIONS: The distinct patterns of regurgitant flow seen in these patients with mitral prosthetic hemolysis were associated with rapid acceleration and deceleration or high peak shear rates, or both. The nature of the flow disturbance produced by the prosthetic regurgitant lesion and the resultant increase in shear stress are more important than the site of origin of the flow disturbance in producing clinical hemolysis.

Aged↗

Doppler index combining systolic and diastolic myocardial performance: clinical value in cardiac amyloidosis.

OBJECTIVES: This study was designed to determine the clinical value of a Doppler-derived index of combined systolic and diastolic myocardial performance in the assessment of cardiac amyloidosis. BACKGROUND: Cardiac amyloidosis is an infiltrative disease with diastolic and systolic dysfunction. Therefore, the index of myocardial performance combining systolic and diastolic time intervals could be a useful predictor of clinical outcome in cardiac amyloidosis. METHODS: The study included 45 patients with biopsy-proved amyloidosis and 45 age-matched normal subjects. All patients had typical echocardiographic features of amyloid cardiac involvement. A Doppler-derived index, defined as the sum of isovolumetric contraction time and isovolumetric relaxation time divided by ejection time, was measured from left ventricular outflow and mitral inflow Doppler velocity profiles recorded during routine echocardiography. The index as well as conventional systolic or diastolic echocardiographic/Doppler variables were related to subsequent outcome. RESULTS: The isovolumetric contraction and relaxation times were prolonged and ejection time was shortened (p < 0.001) in patients with amyloidosis compared with that in normal subjects, resulting in a marked increase of the index from normal values (p < 0.001). In the amyloid group the index was highest in patients with a low stroke index or with both shortened mitral deceleration time and lower ejection fraction. By univariate analysis, New York Heart Association functional class, the index, ejection fraction and mitral deceleration time were significant predictors of outcome. However, by multivariate stepwise regression analysis, functional class and the index were the only independent predictors of survival. CONCLUSIONS: The Doppler-derived index of combined systolic and diastolic myocardial performance correlates with global cardiac dysfunction and is a useful predictor of clinical outcome in patients with cardiac amyloidosis.

Adult↗

Long-term captopril treatment improves diastolic filling more than systolic performance in rats with large myocardial infarction.

OBJECTIVES: This study sought to determine the effects of long-term angiotensin-converting enzyme (ACE) inhibition on left ventricular (LV) diastolic filling in postinfarction heart failure. BACKGROUND: Long-term treatment with ACE inhibitors is beneficial in experimental animals and patients with heart failure. Because this treatment typically produces only small improvements in LV systolic function, we hypothesized that improvements in LV diastolic filling might contribute to the overall beneficial effects of ACE inhibitors after myocardial infarction (MI). METHODS: We performed transthoracic echocardiographic-Doppler examinations in rats 1 and 6 weeks after transmural MI or sham operation. Rats with MI were randomized to no treatment (n = 10) or captopril (2 g/liter in drinking water, n = 8) after the baseline echocardiogram. RESULTS: Six weeks after MI, untreated rats had significant LV dilation compared with sham-operated rats (LV diastolic dimension [mean+/-SEM] 10.7 +/- 0.3 vs. 8.5 +/- 0.3 mm, p < 0.05). Rats with untreated MI also had impaired fractional shortening (9 +/- 1% vs. 34 +/- 2%, p < 0.05) and depressed systolic thickening of the noninfarcted posterior wall (3% +/- 3% vs, 65 +/- 9%, p < 0.05). Rats with MI showed progressively restricted LV diastolic filling as assessed by transmitral Doppler recordings. At 6 weeks, peak early filling velocity (E) was increased (97 +/- 3 vs. 77 +/- 2 cm/s, p < 0.05), E wave deceleration was more rapid (23 +/- 3 vs. 12 +/- 1 m/s2, p < 0.05), isovolumetric relaxation time was decreased (18 +/- 1 vs. 24 +/- 1 ms, p < 0.05), and late filling velocity was lower (26 +/- 7 vs. 34 +/- 1 cm/s, p < 0.05) in rats with MI versus sham-operated rats. Compared with rats with untreated MI, rats receiving captopril had similar LV diastolic dimensions (10.5 +/- 0.35 vs. 10.7 +/- 0.35 mm), slightly higher fractional shortening (16 +/- 2% vs. 9 +/- 1%, p < 0.05 [captopril MI vs. untreated MI]) and unchanged posterior wall thickening (49 +/- 12% vs. 37 +/- 3%, p = 0.3). In contrast, captopril almost completely normalized diastolic filling abnormalities (E velocity 82 +/- 5 cm/s, p < 0.05 [captopril MI vs. untreated MI]; E wave deceleration rate 15 +/- 2 m/s2, p < 0.05 [captopril MI vs. untreated MI]; isovolumetric relaxation time 20 +/- 1 ms). CONCLUSIONS: Long-term captopril treatment in rats with a large MI modestly limits LV remodeling and the development of systolic dysfunction but markedly improves the restrictive diastolic filling abnormalities that are seen in untreated rats.

Angiotensin-Converting Enzyme Inhibitors↗

Radiographic imaging in assessment of combined manubriosternal and spinal fracture.

Deceleration injuries combined with hyperflexion of the torso as seen in motor vehicle accidents can result in combination of sternal and spinal fractures. This type of injury is associated with abnormalities of the soft tissue structures of the thorax. This publication reviews a case report of a deceleration injury and emphasizes the imaging modalities necessary to evaluate this constellation of abnormalities.

Female↗

Competitive and allosteric binding of 2 alpha-DHET and its optical isomers to rat cardiac muscarinic receptors.

The possibility of both competitive and allosteric interactions of 2 alpha-(2',2'-disubstituted-hydroxy-ethoxy)tropane (2 alpha-DHET) and its four optical isomers with rat cardiac muscarinic receptors was studied. 2 alpha-DHET and its optical isomers competitively inhibited the binding of [3H] quinuclidinyl benzilate to rat cardiac muscarinic receptors and allosterically decelerated the dissociation of bound [3H] quinuclidinyl benzilate in a concentration-dependent manner. The rank order of potencies to displace [3H] quinuclidinyl benzilate binding was 1R-2 alpha-2'R > 1S-2 alpha-2'R > 2 alpha-DHET > 1S-2 alpha-2'S > 1R-2 alpha-2'S, while their potencies to decelerate the dissociation of bound [3H] quinuclidinyl benzilate were not significantly different. The allosteric potencies were found not to be correlated with their binding potencies.

Allosteric Site↗

Left ventricular filling as assessed by pulsed Doppler echocardiography after coronary artery bypass grafting.

Diastolic filling of the left ventricle, as assessed by transesophageal pulsed Doppler echocardiography during and in the early phase following coronary artery bypass grafting, was investigated in nine patients without valvular disease or left ventricular hypertrophy. The ratio between the maximal heights of the early diastolic flow-velocity peak and the late (atrial) diastolic flow-velocity peak, the E:A ratio, and also the deceleration time of the early peak were calculated as indices of left ventricular filling. The E:A ratio decreased from 1.01 +/- 0.06 after induction of anesthesia to 0.46 +/- 0.06 on arrival in the intensive care unit (ICU). The E:A ratio then increased and reached 0.87 +/- 0.08 after 6 hours in the ICU. This increase in E:A ratio in the ICU was due to an increasing peak velocity of the E wave. The deceleration time decreased after surgery and increased from 111 +/- 25 to 145 +/- 12 milliseconds in the ICU. Pulsed Doppler indices of diastolic filling are known to be altered by changes in hemodynamic parameters, to be load-dependent, and to vary with heart rate. In the ICU, pulmonary capillary wedge pressure remained unchanged, heart rate decreased by approximately 12%, and systemic vascular resistance decreased by approximately 40%. The changes in hemodynamic parameters could have affected the E:A ratio, but it is unlikely that they could explain the marked increase in the E:A ratio that occurred in the ICU. The results, therefore, imply the presence of impaired diastolic filling immediately after cardiopulmonary bypass with gradual, but not complete, recovery during the first 6 hours in the ICU.

Aged↗

Relation of impaired left ventricular filling to systolic midwall mechanics in hypertensive patients with normal left ventricular systolic chamber function: the Losartan Intervention for Endpoint Reduction in Hypertension (LIFE) study.

BACKGROUND: Patients with hypertensive left ventricular (LV) hypertrophy commonly have diastolic dysfunction with preserved LV ejection fraction. LV systolic midwall shortening (MWS) may be impaired in hypertensive patients with normal LV ejection fraction. However, it is unclear whether impaired LV filling is related to depressed systolic midwall mechanics. METHODS: Echocardiographic measures of LV diastolic filling and systolic performance were compared in 632 unmedicated patients with stage II or III hypertension and LV hypertrophy determined by electrocardiogram, with LV ejection fraction >55% and <2+ mitral regurgitation. RESULTS: Stress-corrected LV MWS, an index of myocardial contractility, was lower in patients with abnormal as opposed to normal LV filling patterns (98% +/- 12% vs 102% +/- 10%, P <.001) and in patients with prolonged as opposed to normal isovolumic relaxation time (IVRT) (98% +/- 13% vs 101% +/- 12%, P =.014). Stress-corrected MWS was <85% of predicted levels in more patients with abnormal LV filling patterns (11.8% vs 6.3%) or with long IVRT (> or =105 msec) (34% vs 21%, both P <.05). In regression analyses, lower stress-corrected MWS and higher LV mass were independent correlates of longer IVRT, while lower stress-corrected MWS was the only independent correlate of prolonged mitral valve deceleration time (P =.017). Higher LV mass had strong, statistically independent relationships to longer IVRT (by 0.3 g/msec) and decreased stress-corrected MWS (by 0.5 g/%; both P <.0001), independent of body size and age. CONCLUSION: In patients with moderate hypertension and target organ damage who have normal LV ejection fraction, impaired early diastolic LV relaxation (abnormal E/A ratio, prolonged IVRT and deceleration time) is associated with impaired LV systolic midwall mechanics independent of higher LV mass.

Aged↗

Left ventricular diastolic function in normotensive subjects 2 months after acute myocardial infarction is related to glucose intolerance.

BACKGROUND: Both glucose intolerance and myocardial infarction are independently associated with impaired left ventricular (LV) function. This study was carried out to relate LV diastolic function in normotensive subjects 2 months after acute myocardial infarction (AMI) to glucose tolerance status. METHODS: Left ventricular ejection fraction (LVEF), LV mass index, peak velocity of the early phase/atrial contraction wave, deceleration time of E wave, and isovolumic relaxation time were measured during echocardiograph/Doppler cardiography in 200 normotensive patients 2 months after AMI. Twenty-nine patients were known to be diabetic on admission with AMI. Glucose tolerance test was carried out in the 171 patients who are not known to be diabetic. RESULTS: Independent of LVEF, restrictive LV filling (peak velocity of the early phase/atrial contraction wave > 1 but < 2 associated with deceleration time of E wave < or = 140 milliseconds) was found in 72% of the known-diabetic patients, 70% of the 20 preclinical diabetic patients, 23% of the 35 patients with impaired glucose tolerance, 13% of the 15 patients with stress hyperglycemia, and 7% of the euglycemic patients (P < .01). In the rest of these patients, LV filling was nonrestrictive. No significant difference was observed in LVEF and LV mass index between patient groups. CONCLUSION: Independent of LVEF, the pattern of abnormal LV filling in normotensive subjects 2 months after AMI is a function of the severity of glucose intolerance, restrictive in the majority of the diabetic patients and nonrestrictive in the majority of the euglycemic patients, impaired glucose tolerance, and stress hyperglycemia. After AMI, abnormal LV filling occurs even in the absence of detectable systolic dysfunction or left ventricular hypertrophy.

Adult↗

Restrictive physiology in cardiogenic shock: observations from echocardiography.

BACKGROUND: Left ventricular diastolic abnormalities are associated with adverse outcome in myocardial infarction. Intra-aortic balloon pump (IABP) support is associated with improved diastolic filling. In the SHOCK trial and registry, average left ventricular ejection fraction (LVEF) was approximately 30%, higher than expected based on the classic paradigm. We hypothesized that restrictive physiology plays a role in cardiogenic shock (CS). METHODS: Echocardiograms obtained during the SHOCK trial within 24 hours of randomization were centrally interpreted. Patients with quantifiable mitral E-wave deceleration time were included (n = 64). The restrictive filling pattern was defined as deceleration time < 140 milliseconds. RESULTS: The restrictive pattern was seen in 60.9% of patients studied. Patients with this pattern had lower LVEF (31.1% vs 39.0%, P = .02) and higher wall motion score index (2.1 vs 1.8, P = .05). Patients with restriction were more likely to have IABP support during echocardiography (73.7% vs 43.5%, P = .03). There was no difference with and without restriction in demographic and hemodynamic variables or in mitral regurgitation degree or extent of coronary disease. The restrictive pattern had positive predictive value of 80% for pulmonary capillary wedge pressure > or = 20 mm Hg. Thirty-day survival was 53.9% with restriction versus 68.0% without restriction, P = .31. There was no difference in New York Heart Association class at 1 year between groups. CONCLUSIONS: The restrictive filling pattern is common in patients with CS, which may suggest that diastolic dysfunction contributes to CS pathogenesis. Patients with the restrictive pattern had lower LVEF despite IABP support. An association between the restrictive pattern and mortality was not demonstrated; power was limited by sample size.

Aged↗

Unselected low-risk pregnancies and the effect of continuous intrapartum fetal heart rate monitoring on umbilical blood gases and cerebral palsy.

OBJECTIVE: Our purpose was to evaluate the clinical validity of electronic fetal heart rate monitoring to detect fetal acidemia and to evaluate the prevalence of cerebral palsy in unselected low-risk pregnancies. STUDY DESIGN: We selected two secondary and two tertiary level institutions in which 10,030 infants were born. Among them, 5546 of the pregnancies were low-risk pregnancies by antepartum evaluation. The fetal heart rate patterns were interpreted according to the guidelines of the National Institute of Child Health and Human Development. The correlations between the fetal heart rate pattern and umbilical blood gases and the fetal heart rate pattern and cerebral palsy were studied. Spastic cerebral palsy was diagnosed at > or =1 year by pediatric neurologists. Statistics included unpaired t test, contingency table with chi(2) and Fisher tests, and one-way analysis of variance with Bonferroni/Dunn test. RESULTS: On the basis of the severity of decelerations, frequency of decelerations, and decreased variability, umbilical pH, and Po(2) level were decreased accordingly, and incidence of pH<7.1 was increased. Sensitivity and false-positive rate of nonreassuring fetal heart rate patterns for fetal acidemia were 63% and 89%. There were nine cerebral palsy cases: six of the cases were preexisting asphyxia before monitoring was initiated, two of the cases were cytomegaloviral infections, and one of the cases was a maternal amniotic fluid embolism. CONCLUSION: In low-risk pregnancies, intrapartum fetal heart rate monitoring was useful to detect fetal acidemia. Cerebral palsy caused by intrapartum asphyxia was restricted to unavoidable accidents under continuous fetal heart rate monitoring.

Acids↗