Factors affecting selectivity in ion chromatography.

Methods for separation of ions by ion-exchange, ion-pair, and zwitterion ion chromatography share at least one common thread--the induced formation of a cation-anion pair in the stationary phase. Selectivity can be defined as the relative ability of sample ions to form such a pair. Examples are given in anion-exchange chromatography to show the effect of variations in the geometry, bulkiness and polarity of the resin cation on selectivity. The type of resin matrix, the hydrophobic nature of the resin surface and the degree of solvation also affect chromatographic behavior. The selectivity series observed in ion chromatography seems to be best explained by the interplay of two components: electrostatic attraction (ES) and the enforced-pairing (EP) that is brought about by hydrophobic attraction and by water-enforced ion pairing. Selectivity in ion-pair chromatography (IPC) and in zwitterion ion chromatography (ZIC) is affected by both the mobile phase cation and anion. This leads to elution orders for anions that are different from conventional ion-exchange chromatography (IC) of anions where cations are excluded from the stationary phase and have little effect on a separation. The elution order of anions in ZIC is similar to that in IC except for small anions of 2-charge, which are retained more weakly in ZIC. A unique advantage of ZIC is that sample ions can be eluted as ion pairs with pure water as the eluent and a conductivity detector. The mechanism for separation of anions on a zwitterionic stationary phase has been a subject for considerable debate. The available facts point strongly to a partitioning mechanism or a mixed mechanism in which partitioning is dominant with a weaker ion-exchange component.

Chromatography, Ion Exchange↗

Secondary isotope effects in liquid chromatography behaviour of 2H and 3H labelled solutes and solvents.

The separation of solutes that differ only in the extent of isotopic substitution of their hydrogen atoms, using either mixtures of isotopically non-modified or perdeuterated solvents as mobile phases, is described. The occurrence of a secondary isotope effect is demonstrated in reversed-phase liquid chromatography, which is independent of the nature of the stationary phase (different octadecyl-bonded silicas, an embedded alkylamide-bonded silica, as well as one polymeric stationary phase were tested), and the water content and the nature of organic modifier of the mobile phase. The separation of 24 structurally different isotopologue pairs (apolar compounds and polar compounds with exchangeable or non-exchangeable hydrogen atoms) is examined using reversed-phase liquid chromatography. It is found that the greater the number of isotopically substituted hydrogen atoms in a given organic solute, the better is the separation of a particular isotopologue pair. The single secondary isotope effect is shown to be dependent on the number of isotopic substitutions. The greater the number of these substitutions, the smaller is the single isotope effect. The single secondary isotope effect is higher for aromatic hydrocarbons than for aliphatic hydrocarbons. A secondary isotope effect is also observed in chiral chromatography and normal-phase liquid chromatography, as well as on changing the nature of the substituting isotope, i.e.: tritium instead of deuterium. Thus, we have demonstrated that the total secondary isotopic effect for hydrogen/tritium is higher than for hydrogen/deuterium. This isotope effect involves only the consequences of changes in interactions due to nuclear motions. Overall this study confirms the predominance of hydrophobic effects in retention processes in reversed-phase liquid chromatography. In reversed-phase liquid chromatography, a secondary isotope effect related to mobile phase composition is also observed. The behaviour of deuterium oxide and water in mobile phases of the same composition (%, w/w) is compared. Independent of the nature of the organic modifier (methanol, acetonitrile or ethanol), the effect of replacing H2O with 2H2O in the mobile phase, is an increase in the retention factors and an improvement in the chromatographic resolution of isotopologue pairs. This increase in the resolution is not accompanied by a change in the chromatographic selectivity. The measurement of liquid-liquid extraction coefficients proves that the effect is mainly due to the modification of the phase ratio. In general the effect of 2H-labelled solvents (2H2O and C2H3CN) as mobile phase components, compared to their isotopically non-modified isomers, can be rationalized on the basis of their lower polarisabilities. Overall the use of perdeuterated rather than isotopically non-modified solvents as mobile phase components leads to the most efficient separation systems.

Chromatography, High Pressure Liquid↗

Purification of microcystins by DEAE and C(18) cartridge chromatography.

Microcystins (MCs) were purified by DEAE and C(18) cartridge chromatography. Addition of EtOH to the eluents (20%) in DEAE chromatography gave higher resolution than no addition of EtOH. The chromatogram showed three peaks: MC-LR; MC-LY and MC-LF; MC-LW. MC-LR and MC-LW were obtained by one step chromatography with purity of 96 and 88%, respectively. The separation of MC-LF and MC-LW with DEAE chromatography was better than that with reversed-phase chromatography. MC-LY and MC-LF were separated with C(18) cartridge. On the chromatogram, there were three peaks consisting of MC-LY (81% purity), MC-LF (86%), and an unknown compound which was considered as a MC variant judging from the results in HPLC/PDA, FAB-MS, and 1H NMR analyses, but the structure could not be determined. It is concluded that the combination of DEAE and C(18) cartridge chromatography would be a practical approach for the purification of various MCs.

Bacterial Toxins↗

Application of supercritical fluid chromatography to characterize a labile digitalis-like factor.

A sodium pump inhibitor (digitalis-like factor), isolated from the peritoneal dialysate of volume-expanded, hypertensive patients with kidney failure who were treated with this dialysis modality, was further purified and characterized by means of supercritical fluid chromatography, a separation technique whose application to very-low-concentration biomolecules is new. Previous studies suggested that after high-performance liquid chromatography (HPLC) purification, this inhibitor was the only factor correlated with volume status and blood pressure in these patients. When this same HPLC fraction was furthered purified on 2-dimensional supercritical fluid chromatography, a single peak coeluted with [Na,K]ATPase inhibitory activity. When split specimens were used, there was a strict correlation between the peak area, measured by flame ionization detection, and activity (n=10, R=0.98, P=0.00001). Inhibitory activity after supercritical fluid chromatography was still correlated with the degree of volume expansion of donor patients (P=0.01). After HPLC purification, this volume-sensitive inhibitor was chemically labile. With further purification on supercritical fluid chromatography, the active peak was still labile with comparable half-life. Supercritical fluid chromatography coupled with flame ionization detection provided an estimate of the amount of the inhibitor present. Again using split specimens, we determined that the labile digitalis-like factor was approximately 30-fold more effective than ouabain in inhibiting renal [Na,K]ATPase activity and >/=500 times more effective than ouabain in causing vascular smooth muscle contraction. The data suggest that we have purified to homogeneity a labile digitalis-like factor that is readily distinguished from ouabain or bufalin, based on chromatographic characteristics, chemical lability, and a much lower effective concentration for its biological activity.

Cardenolides↗

Prenatal diagnosis of hemoglobinopathies: a potential application of high performance liquid chromatography.

High performance liquid chromatography was compared with carboxymethyl cellulose column chromatography data for analysis of globin chain composition and biosynthetic ratios in fetal blood. A formula was derived for mathematical correction for losses of small amounts of globin protein on the high performance liquid chromatography column. Radioactive globin chain ratios by high performance liquid chromatography are equivalent to those by carboxymethyl cellulose column chromatography, but only when carrier Hb A is added. We conclude that high performance liquid chromatography provides a suitable alternative to carboxymethyl cellulose columns, and has several advantages.

Carboxymethylcellulose Sodium↗

Rapid method for purification of Clostridium botulinum type C neurotoxin by high performance liquid chromatography (HPLC).

The culture supernatant of Clostridium botulinum type C, concentrated by addition of RNA, acid precipitation and subsequent protamine treatment was used as starting material for rapid purification of L toxin (mol. wt. ca. 500K) and M toxin (mol. wt. ca. 350K) of C1 neurotoxin by ion-exchange chromatography on a Mono S column by fast performance liquid chromatography (FPLC). L and M toxins were highly purified further by gel permeation chromatography through a TSK G3000SW column at pH 6.0 by high performance liquid chromatography (HPLC). Purified S toxin (mol. wt. ca. 150K, C1 neurotoxin without a nontoxic component) was then obtained from L toxin rapidly by gel permeation chromatography at pH 7.3 through a TSK G3000SW column by HPLC. Purified S toxin was also obtained rapidly from M and L toxins by ion-exchange chromatography on a Mono Q column at pH 8.0 using an FPLC system. The purified preparations of L, M and S toxins gave single bands on conventional polyacrylamide gel electrophoresis, and had specific activities of 2.8, 6.7, and 14-21 X 10(7) LD50/mg N, respectively, in mice. On immunoelectrophoresis, purified S toxin gave a single arc against anti-crude toxin serum. The yield of toxicity as L and M toxins was 73.1% (32.5% as L toxin and 40.6% as M toxin) from the protamine-treated concentrated culture supernatant. The recovery of toxicity as S toxin from purified L or M toxin was almost 100% (97.6-100% of L toxin and 97.5% of M toxin). These procedures provide a rapid method for purifying L and M toxins, which have stable toxicities.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

On hen egg fractionation: applications of liquid chromatography to the isolation and the purification of hen egg white and egg yolk proteins.

Liquid chromatography has been used as a means of egg protein analysis or as a method for the purification of egg proteins. Several chromatographic methods, including gel permeation, ion-exchange, reversed-phase, hydrophobic interaction, and immobilized-ligand-affinity chromatography, have been carried out for the separation or the purification of egg yolk or egg white proteins. Ion-exchange chromatography appears to be the most frequently used method for protein isolation and it is the easiest to adapt to a process scale. From an analytical point of view reversed-phase chromatography is, at the moment, the recommended method for egg white analysis. Egg white has been fractionated more often by liquid chromatography than has egg yolk. Several chromatographic methods have been developed on a laboratory scale, but the application of these techniques on an industrial scale remains limited.

Animals↗

Linear multidimensional liquid chromatography in the preparative scale purification of calmodulin from brain extract.

Rapid preparative scale purification of calmodulin from crude bovine brain extract is achieved in a single chromatographic run by physically coupling two different liquid chromatography columns which employ different separation mechanisms. In this case columns packed with newly commercialized 40-microns silica-based hydrophobic interaction and 5-microns micron silica-based weak anion-exchange chromatography media were used. The only sample preparation required for conducting this purification procedure is the addition of salt to the crude brain supernatant to promote the initial binding of calmodulin to the hydrophobic interaction chromatography media. Chromatography carried out on such linear arrangements of columns has been referred to as linear multidimensional liquid chromatography.

Animals↗

Application of high-performance liquid chromatography to the purification of the putative intestinal peptide transporter.

A membrane protein of relative molecular mass (Mr) 127,000 was identified by photoaffinity labelling as (a component of) the uptake system for small peptides and beta-lactam antibiotics in rabbit small intestine. This binding protein is a microheterogeneous glycosylated integral membrane protein which could be solubilized with non-ionic detergents and enriched by lectin affinity chromatography on wheat germ lectin agarose. For the final purification of this protein and separation from aminopeptidase N of Mr 127,000, fast protein liquid chromatography (FPLC) was used. Gel permeation, hydroxyapatite and hydrophobic interaction chromatography were not successful for the purification of the 127,000-dalton binding protein. By anion-exchange chromatography on a Mono Q column with either Triton X-100 or n-octylglucoside as detergent, a partial separation of the 127,000-dalton binding protein from aminopeptidase N was achieved. By cation-exchange chromatography on a Mono S HR 5/5 column at pH 4.5 using Triton X-100 as detergent also only a partial separation from aminopeptidase N could be achieved. If, however, Triton X-100 was replaced with n-octylglucoside, the binding protein for beta-lactam antibiotics and small peptides of Mr 127,000 could be completely separated from aminopeptidase N. These results indicate that Triton X-100 should be avoided for the purification of integral membrane proteins because mixed protein-detergent micelles of high molecular weight prevent a separation into the individual membrane proteins. The putative peptide transport protein was finally purified by rechromatography on Mono S and was obtained more than 95% pure as determined densitometrically after sodium dodecyl sulphate gel electrophoresis. By application of FPLC even microheterogeneous membrane glycoproteins from the intestinal mucosa can be purified to such an extent that a sequence analysis and immunohistochemical localization with antibodies prepared from the purified protein is possible.

Affinity Labels↗

Purification of bovine liver rhodanese by low-pH column chromatography.

We report a purification of bovine liver rhodanese (thiosulfate:cyanide sulfurtransferase, EC 2.8.1.1) using column chromatography under conditions that take advantage of recent information regarding the structure and stability of this enzyme. At low pH (e.g., pH 4-6), rhodanese is stabilized against inactivation processes. By maintaining rhodanese at low pH, column chromatography, and especially ion-exchange chromatography, becomes practical, without loss of enzymatic activity. A purification method involving the sequential use of cation-exchange, size-exclusion, and hydrophobic-interaction chromatography was developed, and rhodanese was purified with good yield to electrophoretic purity and high specific activity. Previous methods for purifying bovine liver rhodanese employ repeated ammonium sulfate fractionations and crystallization of the rhodanese. In these methods, it is difficult to separate rhodanese from yellow-brown contaminants in the final stages of the procedures. Here, yellow-brown contaminants, which copurify with rhodanese on the first two columns, are completely resolved by hydrophobic interaction chromatography. This method can be readily scaled up, requires no special equipment, eliminates the variability inherent in previous methods, and is less dependent upon experience.

Animals↗

The chemical interpretation and practice of linear solvation energy relationships in chromatography.

This review focuses on the use of linear solvation energy relationships (LSERs) to understand the types and relative strength of the chemical interactions that control retention and selectivity in the various modes of chromatography ranging from gas chromatography to reversed phase and micellar electrokinetic capillary chromatography. The most recent, widely accepted symbolic representation of the LSER model, as proposed by Abraham, is given by the equation: SP=c + eE + sS + aA + bB + vV, in which, SP can be any free energy related property. In chromatography, SP is most often taken as logk' where k' is the retention factor. The letters E, S, A, B, and V denote solute dependent input parameters that come from scales related to a solute's polarizability, dipolarity (with some contribution from polarizability), hydrogen bond donating ability, hydrogen bond accepting ability, and molecular size, respectively. The e-, s-, a-, b-, and v-coefficients and the constant, c, are determined via multiparameter linear least squares regression analysis of a data set comprised of solutes with known E, S, A, B, and V values and which span a reasonably wide range in interaction abilities. Thus, LSERs are designed to probe the type and relative importance of the interactions that govern solute retention. In this review, we include a synopsis of the various solvent and solute scales in common use in chromatography. More importantly, we emphasize the development and physico-chemical basis of - and thus meaning of - the solute parameters. After establishing the meaning of the parameters, we discuss their use in LSERs as applied to understanding the intermolecular interactions governing various gas-liquid and liquid-liquid phase equilibria. The gas-liquid partition process is modeled as the sum of an endoergic cavity formation/solvent reorganization process and exoergic solute-solvent attractive forces, whereas the partitioning of a solute between two solvents is thermodynamically equivalent to the difference in two gas/liquid solution processes. We end with a set of recommendations and advisories for conducting LSER studies, stressing the proper chemical and statistical application of the methodology. We intend that these recommendations serve as a guide for future studies involving the execution, statistical evaluation, and chemical interpretation of LSERs.

Chemical Phenomena↗

The effect of the mobile phase additives on sensitivity in the analysis of peptides and proteins by high-performance liquid chromatography-electrospray mass spectrometry.

The study of the effect of mobile phases on sensitivity in the analysis of peptides and proteins by high-performance liquid chromatography (HPLC)-electrospray mass spectrometry (ESI-MS) has been the aim of this review. Reversed-phase chromatography (RPLC) is the chromatographic mode most suitable for coupling with ESI-MS since mobile phases containing organic modifiers are used. The analysis of proteins and peptides by RPLC mostly involves the use of trifluoroacetic acid (TFA) as an ion-pairing agent despite its being a strong suppressor of the MS signal. Different studies reporting the effects of using other ion-pairing agents (other perfluorinated acids, acetic acid, formic acid, etc.) and buffers (ammonium acetate, ammonium formate, ammonium bicarbonate, morpholine, etc.) in RPLC-ESI-MS of proteins and peptides did not yield a single strong candidate that could generally replace TFA. The enhancement in sensitivity with other reagents observed in some cases strongly depended on the analyte, the experimental conditions used, and the mass spectrometer and, usually, it did not compensate for the loss in separation resolution related to TFA. The examples of direct coupling of affinity, size-exclusion, or ion-exchange chromatography (IEC) to ESI-MS are very limited because of incompatibilities related to the use of mobile phases containing high salt concentrations. To overcome this problem, an intermediate desalting step is needed. Multidimensional chromatography, microdialysis, and ion-capture modules can be used to couple these chromatographic modes with ESI-MS. Multidimensional chromatography with RPLC as a second dimension has most often been used. Although most examples involve the trap and analysis in the second dimension of a certain part of the first separation, some comprehensive analyses of the entire sample in the second dimension have also appeared.

Chromatography, Affinity↗

High-performance liquid chromatography of membrane proteins.

Various modes of high-performance liquid chromatography, gel filtration, ion-exchange chromatography, hydrophobic interaction chromatography, reversed-phase chromatography and metal chelate affinity chromatography, were investigated for the separation of membrane proteins. All were found applicable to membrane proteins, although the usefulness of each mode differed. For satisfactory results it was important to select appropriate elution conditions. The type and concentration of detergent was of special importance. The effects of other conditions, flow-rate, gradient steepness, type of buffer and salt, eluent pH, etc., were similar to those observed for soluble proteins.

Animals↗

[Clinical application of fast protein liquid chromatography (FPLC) system].

FPLC system is a high-performance liquid chromatography system, designed specifically for separation of proteins, peptides and polynucleotides. Many kinds of column have been prepared, including Mono Q, Mono S, Mono P, Superose, etc. for ion exchange chromatography, chromatofocussing, gel filtration, hydrophobic chromatography, reversed phase chromatography and affinity chromatography. It is a fast and simple system for separation of proteins in various body fluids, particularly plasma, urine and cerebrospinal fluid.

Chromatography, Affinity↗

Ultra-high flow rate capillary liquid chromatography with mass spectrometric detection for the direct analysis of pharmaceuticals in plasma at sub-nanogram per millilitre concentrations.

Ultra-high flow rate liquid chromatography on large particle size stationary phases coupled with mass spectrometric detection (particularly tandem mass spectrometry, MS/MS) is gaining increasing usage for the direct determination of pharmaceuticals in biological fluids. The lack of sample preparation required prior to chromatographic and MS/MS analysis, together with the extremely high throughput of the chromatography, make the technique extremely attractive to the modern pharmaceutical bioanalyst. However, this lack of sample preparation also means that there is no potential for concentration of the sample and, as a consequence, the sensitivity of the technique has been limited. Liquid chromatography on the capillary scale offers sensitivity benefits compared with conventional liquid chromatography as the volume in which the analyte peaks are eluted is greatly reduced. In this paper, we present the use of ultra-high flow rate liquid chromatography on the capillary scale. This enables the quantification of drugs in plasma at sub-nanogram per millilitre concentrations from a very small (2.5 micromgL) aliquot of plasma without sample preparation. We also compare the resolution obtained by ultra-high flow rate liquid chromatography with that achieved on short columns packed with conventional size packing materials operated in an isocratic manner.

Animals↗

Affinity monolith chromatography.

The combined use of monolithic supports with selective affinity ligands as stationary phases has recently given rise to a new method known as affinity monolith chromatography (AMC). This review will discuss the basic principles behind AMC and examine the types of supports and ligands that have been employed in this method. Approaches for placing affinity ligands in monoliths will be considered, including methods based on covalent immobilization, biospecific adsorption, entrapment, and the formation of coordination complexes. Several reported applications will then be presented, such as the use of AMC for bioaffinity chromatography, immunoaffinity chromatography, immobilized metal-ion affinity chromatography, dye-ligand affinity chromatography, and biomimetic chromatography. Other applications that will be discussed are chiral separations and studies of biological interactions based on AMC.

Chromatography, Affinity↗

Structural assessment of beta-glucuronidase carbohydrate chains by lectin affinity chromatography.

Rat liver beta-glucuronidase was studied by sequential lectin affinity chromatography. beta-Glucuronidase glycopeptides were obtained by extensive Pronase digestion followed by N-[14C]acetylation and desialylation by neuraminidase treatment. According to the distribution of the radioactivity in the various fractions obtained by chromatography on different lectins, and on the assumption that all glycopeptides were acetylated to the same specific radioactivity, a relative distribution of glycan structure types is proposed. The presence of complex biantennary and oligomannose type glycans (56.8% and 42.7%, respectively) was indicated by Concanavalin A-Sepharose chromatography. Ulex europaeus agglutinin-agarose chromatography revealed the presence of alpha(1-3)linked fucose in some of the complex biantennary type glycans (16.6% of the total glycopeptides). Wheat germ agglutinin chromatography indicated that the minority (0.5%) were hybrid or poly (N-acetyllactosamine) type glycans. Furthermore, the absence of O-glycans, tri-, tetra- and bisected biantennary type glycans was demonstrated by analysis of Concanavalin A-Sepharose unbound fraction by chromatography on immobilized soybean agglutinin, Ricinus communis agglutinin and Phaseolus vulgaris erythroagglutinin.

Animals↗

Purification of 125I-labeled succinyl cyclic nucleotide tyrosine methyl esters by high-performance liquid chromatography.

Carrier free 125I-labeled succinyl cyclic adenosine monophosphate (ScAMP) and succinyl cyclic guanosine monophosphate (ScGMP) tyrosine methyl esters (TME) were purified by reversed phase high-performance liquid chromatography (HPLC) or descending paper chromatography. Using an isocratic buffer for HPLC, mono-ScAMP-125I-TME and mono-ScGMP-125I-TME were eluted from a C18 column at 8.9 and 6.9 min, respectively. Both of the mono-iodinated radioligands were completely separated from their noniodinated precursors and other iodinated products. The radioligands purified by HPLC or paper chromatography were used for the radioimmunoassay (RIA) of cAMP and cGMP. Cyclic AMP or cGMP inhibited binding of the HPLC purified radioligands at three- to fivefold lower concentrations than the paper chromatography purified radioligands. The sensitivity of the RIA decreased with time if paper chromatography purified radioligands were used, but remained stable for 4 months if the HPLC purified compounds were used, even with storage at 4 degrees C. We attribute these results to better purification of radioligands by the HPLC than by the paper chromatography. Using optimal conditions the HPLC method takes only 10 min and results in a high yield (greater than 95%) of added 125I into the monoiodinated products.