Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CASTS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Treatment of scaphoid fractures with a removable cast.

Forty-four fractures of the scaphoid bone were treated with a short-term removable orthoplast cast and compared with 48 fractures treated with a conventional long-arm plaster cast. At the follow-up, there was no difference between the two treatment groups as regards nonunion or other sequelae. We conclude that the inconvenience of the treatment of scaphoid fracture and the need of physiotherapy can be reduced by using an orthoplast cast.

Carpal Bones↗

Cast or external fixation for fracture of the distal radius. A prospective study of 126 cases.

In a prospective 4-year study, 126 consecutive patients with a fracture of the distal radius were followed. Functional, anatomic, and radiographic final results of fixation with above-the-elbow cast immobilization were compared with the results obtained with external fixation. The results following external fixation of comminuted intraarticular fractures were better than those of similar fractures treated in a cast. Aged osteoporotic patients tolerated better residual deformities, and the clinical results had a relatively low correlation with the final anatomic alignment. We suggest that extraarticular fractures of the distal radius should be treated with cast immobilization. Comminuted intraarticular fractures of the distal radius should be treated with external fixation, which maintains accurate anatomic position until solid fracture healing is achieved.

Adult↗

External fixation or plaster cast for severely displaced Colles' fractures? Prospective 1-year study of 46 patients.

In a prospective randomized study of 47 severely displaced Colles' fractures, 23 had external fixation and 24 had a dorsal plaster cast. Five fractures in the plaster-cast group redislocated and were externally fixed at rereduction after the 11-day follow-up. Three patients in the external-fixation group had a noncomplicated pin-tract infection, and 1 patient had a transient sensory disturbance arising from the cutaneous branch of the superficial radial nerve. After 1 year, the patients allocated to primary external fixation had a better radiographic and functional end result; according to Lidström's grading, 19/22 were excellent or good after external fixation as compared with 12/19 after plaster-cast treatment.

Adult↗

A physiological comparison of the short-leg walking cast and an ankle-foot orthosis walker following 6 weeks of immobilization.

Iatrogenically induced weakness, stiffness, and functional impairment associated with classical methods of short-leg cast immobilization have long been recognized. This study compares the effects of "controlled" immobilization with an ankle-foot orthosis (AFO) and short-leg cast (SLC) immobilization for 6 weeks. A significant reduction in loss of range of motion, muscular strength, and muscular atrophy, ie, functional impairment, at the time of cessation of immobilization was noted when an AFO was used. The additional advantages of an AFO are the elimination of multiple cast changes including economic benefits, ease in the assessment of functional improvement during treatment, and convenient adjustment for swelling and atrophy.

Adult↗

Complications related to postoperative casting after surgical treatment of subluxed/dislocated hips in patients with cerebral palsy.

Three hundred sixteen subluxed/dislocated hips (222 patients) underwent upper femoral osteotomy. Of these, 286 (90.5%) hips were casted (average patient age: 8.9 years) and 30 (9.5%) were not (average patient age: 13.6 years). Average follow-up was 4.7 years. Complications in the casted/noncasted groups (per hip) were: 43/0 (15%/0%) skin sores; 11/1 (3.8%/3.3%) wound infections; 6/0 (2.1%/0%) instrumentation failures; 22/1 (7.7%/3.3%) reoperations; and 13/1 (4.5%/3.3%) rehospitalizations. Differences between the groups were not statistically significant. Casted patients were younger and more neurologically involved. Casting is useful to ensure healing of osteotomies, prevent instrumentation failure and injury to the operated legs, and allow for ease of handling. Complications that occurred were managed and had no long-term sequelae.

Adolescent↗

Development of the computerized dental cast form analyzing system--three dimensional diagnosis of dental arch form and the investigation of measuring condition.

To analyze the functional and morphological harmonies of the tooth and dental arch, a computerized system to measure a dental cast and to detect the apex of dental cusps and angle points of incisors was developed. Detailed morphology in the measured dental cast could be displayed distinctively by computer graphics (CG) with a surface model. Accuracy in determining the position of the apex of the dental cusp was examined by increasing the measuring pitch from 50 microns to 400 microns, the error increased gradually with increased measuring pitch. Taking the measuring error, the time for measurement and the memory size for analysis into account, a measuring pitch of 200 microns was determined to be reasonable. Three-dimensional data measurements from the apex of the dental cusp in molar, and the mesial and distal angles in canine and incisor were fitted to a polynomial formula. In the present measured model, the 4th order polynomial formula was used for the dental arch, and the 2nd order polynomial formula was used for the anteroposterior and lateral occlusal curves. These formulae could be simultaneously superimposed on the surface model of the dental cast, and displayed using CG.

Computer Graphics↗

Mechanical properties and microstructures of dental cast Ti-Ag and Ti-Cu alloys.

In this study, experimental Ti-Ag alloys (5, 10, and 20 mass% Ag) and Ti-Cu alloys (2, 5, and 10 mass% Cu) were made in an argon-arc melting furnace. The alloys were cast into magnesia molds using an argon gas-pressure dental casting machine, and the mechanical properties and microstructures of the castings were investigated. As the concentration of silver or copper in the alloys increased, the tensile strength, yield strength, and hardness of the alloys became higher than those of CP Ti, and the elongation of the alloys became lower than that of CP Ti. Changes in the mechanical properties by alloying were considered to be caused by solid-solution strengthening of the a-phases and by precipitation of intermetallic compounds.

Chemical Phenomena↗

Mechanical properties and grindability of dental cast Ti-Nb alloys.

Aiming at developing a dental titanium alloy with better mechanical properties and machinability than unalloyed titanium, a series of Ti-Nb alloys with Nb concentrations up to 30% was made. They were cast into magnesia-based molds using a dental casting machine and the mechanical properties and grindability of the castings were examined. The hardness of the alloys with Nb concentrations of 5% and above was significantly higher than that of titanium. The yield strength and tensile strength of the alloys with Nb concentrations of 10% and above were significantly higher than those of titanium, while the elongation was significantly lower. A small addition of niobium to titanium did not contribute to improving the grindability of titanium. The Ti-30% Nb alloy exhibited significantly better grindability at low grinding speed with higher hardness, strength, and Young's modulus than titanium, presumably due to precipitation of the omega phase in the beta matrix.

Dental Alloys↗

Clinical application of a static splitting agent for removing the denture from its cast after curing.

A very effective method for removing a denture from its cast after curing has been developed using a static expansive agent for hydration. Three filling hole designs for packing the expansive agent into a stone cast were examined to obtain the most effective method of splitting the cast for clinical application. The dynamic strain in the resin denture base was measured during static splitting one filling hole design was the safest for handling and the most effective for removing the denture. The upper tolerance limits for the maximum strain were estimated to be 2.9 x 10(-3) in the upper denture and 3.4 x 10(-3) in the lower denture. These values were lower than one-third of the critical strain corresponding to the proportional limit of the denture resin.

Calcium↗

Upper extremity casting: adjunct treatment for a child with cerebral palsy hemiplegia.

A common upper extremity deformity with hemiplegia is pronation contracture of the forearm in association with flexion contracture of the elbow. Early management of the child with hemiplegic cerebral palsy is critical in optimizing overall function. The use of inhibitory upper extremity casting can enhance function and improve arm-hand position. The present paper describes the evaluation process before casting, the goals of each phase of the casting program, and the follow-up.

Arm↗

Contralateral limb during total contact casting. A dynamic pressure and thermometric analysis.

The authors draw attention to the importance of evaluation of the contralateral limb when treating unilateral sequelae secondary to distal symmetrical polyneuropathy. Plantar pressure measurements of the contralateral limb during total contact casting are reviewed. The results of thermometric evaluation before and after initiation of repetitive stress were reviewed. The results suggest that the patient walking in a total contact cast may experience a reduced focal pressure on the contralateral limb when compared with uncasted walking and three-point walking with crutches. Dermal thermometry may be a highly sensitive tool in evaluating even mild increases in repetitive stress. To explain this decrease in contralateral stress, the authors examine the features inherent to the total contact cast and propose the concept of proprioceptive stability.

Casts, Surgical↗

Postoperative blood loss into plaster casts after clubfoot surgery: an experimental model.

With major surgery in mind, a simple experimental model was used to study the potential blood loss into plaster of Paris casts. Three lower limb models were used to represent a 3-year-old, a 1-year-old, and a 6-month-old. Two thicknesses of plaster were compared in terms of blood volume required to produce staining on the surface of the cast. Whole blood from the laboratory was infused onto the plaster models at various rates. While allowing for the limitations of the model, the blood volume required before staining through the plaster when three plaster rolls were used was an average of 160 mL in the 6-month-old model and 310 mL in the 3-year-old modal, representing 31.4% and 29.5% of total blood volume, respectively. When only two rolls of plaster of Paris were used, an average of 80 mL in the 6-month-old and 180 mL in the 3-year-old model were lost, representing 15.7% and 17% of total blood volume, respectively. This potential blood loss should be borne in mind during major pediatric foot surgery. The use of drains, releasing the tourniquet before wound closure, and casting with two rather than three rolls of plaster are suggested precautions.

Age Factors↗

Post and core fabrication for divergent canals with a cast post and core and a prefabricated dowel.

A post and core fabrication technique for multirooted teeth with divergent canals uses a combination cast post and core and prefabricated dowel. This method modifies and improves a previously reported method by using a nickel-silver technique post during casting to preserve the channel in the resin core pattern. Following casting, the nickel-silver post is dissolved with nitric acid. Minimal hand instrumentation with a post drill leaves a clean and accurate channel for cementation of an accessory prefabricated stainless steel or titanium post.

Dental Casting Technique↗

Long-term cytotoxicity of dental casting alloys.

PURPOSE: Current in vitro cytotoxicity tests for dental casting alloys may be inadequate because they use a short-term test (generally < 168 h) for a material that is present in the mouth for years. A modified in vitro test was used to test the cytotoxicity of 8 dental casting alloys and 3 pure metals. This modified test attempted to simulate the long-term effects of dental casting alloys in the mouth. MATERIALS AND METHODS: Alloys were tested in cell culture either immediately after polishing (initial) or after 10 months of conditioning in a biologic medium containing serum proteins. The cytotoxicities of the 2 conditions were then compared. Alloys were repolished to assess the reversibility of the 10-month conditioning. RESULTS: Alloys with little initial cytotoxicity showed no 10-month cytotoxicity. Alloys with significant initial toxicity showed significantly less toxicity at 10 months. No alloy increased in toxicity after conditioning. Repolishing multiple times did not necessarily reestablish the initial cytotoxicity response. CONCLUSION: The results indicate that short-term cytotoxicity tests may not accurately measure the long-term cytotoxicity of these types of alloys.

3T3 Cells↗

Comparative evaluation of effect of auxiliary retentive features on retention of complete cast crowns in teeth with adequate and inadequate crown height. An invitro study.

This study was done to evaluate the retention of complete cast crowns in teeth with adequate and inadequate crown height and to evaluate the effects of auxiliary retentive features on retention from of complete cast crowns. Thirty-six extracted human maxillary first premolars were obtained. In one group teeth were prepared to a constant height of 3.5 mm and in the second group teeth were prepared to a constant height of 2.5 mm. Each group was further subgrouped into three. In the first subgroup teeth were prepared conventionally, second subgroup proximal grooves were incorporated and in the third subgroup proximal boxes were incorporated. Tensional forces required to dislodge each cemented casting from its preparation was used for comparison of retention quality. These results were then subjected to an analysis of variance (ANOVA). The retention of crown in tooth with adequate crown height were statistically highly significant (P < 0001), compared to inadequate crown height and in boxes compared to grooves and conventional preparation.

Analysis of Variance↗

[Follow-up studies on model cast prostheses after 4 years wear].

Over a period of 4-1/2 years, patients having model cast dentures that had been inserted in the dental office were checked and submitted to follow-ups. It became evident that the socalled pre-prosthetical measures had been performed in a non-satisfying manner. In 69% of the patients, teeth had been extracted directly before inserting the model cast denture. As a result thereof, a majority of the dentures was sagging after a relatively short time and 70% of the dentures revealed non-occlusion in the final follow-up. 47% of the dentures had to be modified because of necessary tooth extractions, thereby reducing the original number of abutment teeth by 19%. About a third of the inserted model cast dentures showed gross deficiences, the percentage of socalled "collar" constructions was relatively high.

Dental Casting Technique↗

Casting acute fractures. Part 2--Generic preparation and application of plaster slabs.

BACKGROUND: Slabs are ideal initial splints for the emergency treatment of many fractures. Construction of a broader slab of appropriate thickness with appropriate supportive elastic bandages produces a stronger, safer and more comfortable cast. OBJECTIVE: This article will introduce and demonstrate new materials and concepts that may be applied to slab construction in a generic fashion. It will form the basis for applying specific slabs demonstrated later in the series. DISCUSSION: The primary care physician is expected to apply slabs. Often his training has been minimal. The techniques shown are those used by full time casting technicians. These trade secrets are easily reproducible. Mastery will reduce material and labour costs for the general practitioner. The patient will have a stronger, more comfortable cast and fewer unplanned return visits.

Acute Disease↗

A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study.

PURPOSE: The purpose of this prospective multicenter study was to evaluate and compare the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with conventional cast frameworks. MATERIALS AND METHODS: Forty-two partially edentulous patients were provided with Brånemark system implants and arranged into 2 groups. Group A was provided with a conventional cast framework with porcelain veneers in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain on the other side. The patients in group B had an old implant prosthesis replaced by a titanium framework prosthesis. The patients were followed for 3 years after prosthesis placement. Clinical and radiographic data were collected and analyzed. RESULTS: Only one implant was lost, and all prostheses were still in function after 3 years. The 2 framework designs showed similar clinical performance with few clinical complications. Only one abutment screw (1%) and 9 porcelain tooth units (5%) fractured. Four prostheses experienced loose gold screws (6%). In group A, marginal bone loss was similar for both designs of prostheses, with a mean of 1.0 mm and 0.3 mm in the maxilla and mandible, respectively. No bone loss was observed on average in group B. No significant relationship (P > 0.05) was observed between marginal bone loss and placement of prosthesis margin or prosthesis design. CONCLUSION: The use of laser-welded titanium frameworks seems to present similar clinical performance to conventional cast frameworks in partial implant situations after 3 years.

Adolescent↗