Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Automatism”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

The computer-based anesthetic monitors: the Duke Automatic Monitoring Equipment (DAME) system and the microDAME.

From 1972 to 1983 the Duke University Department of Anesthesiology designed, built, and maintained most of its own operating room patient monitoring equipment. Construction of a new hospital facility in 1980 provided the opportunity to design and test a new computer-based system, the Duke Automatic Monitoring Equipment (DAME) System. The system consist of microcomputer-based instrumentation on monitoring carts, which communicate with a central minicomputer that allows selection of different software monitoring packages based on the needs of the patient. Multiple problems, including frequent total monitoring failures during surgery, plagued the DAME System in its first year of operation. Despite resolution of many of these problems, user acceptance was poor because of the large size and weight of the monitoring carts, the inadequate quality of displayed physiological waveforms, and inability to overcome the difficulties of the man-machine interface. Because the remaining problems could not be rectified with the existing monitoring carts, a new generation of monitors was designed. The smaller, multiprocessor microDAME was designed to be as automatic and user tolerant as possible. It would omit much of the flexibility that had proved undesirable in the DAME system. When the microDAME was nearly completed, however, departmental research in that area ceased. It remains for others to apply our experiences to further improve operating room patient monitors.

Anesthesiology↗

Will we see automated record keeping systems in common use in anesthesia during our lifetime? The automated anesthetic record will not automatically solve problems in record keeping.

The proponents of automated anesthetic records list the ostensibly logical reasons for them and then claim that automated records will make everything better. The logic goes as follows: (1) It is good to have accurate records because accurate records (a) make clinical decision making more effective and improve patient safety, (b) provide better defense against frivolous lawsuits, and (c) enable more astute medical policy decisions based on improved retrospective case reviews; (2) automatic record-keeping systems will give more nearly accurate records; (3) therefore, quality of care will improve if we acquire automatic record-keeping systems. This logic fails on several counts, which are detailed in this essay. Having said all this, however, I do believe that automated record systems will be implemented and they will be extremely useful, both for the patient and for those who care for the patient. However, we must exercise great care in their design and implementation, lest they wind up doing more harm than good.

Anesthesia↗

Microcomputer system for automatic identification of the Cryptococcus neoformans and its clinical application.

In this study, microcomputer image processing and pattern recognition technology, and the knowledge of morphology and optical characteristics of Cryptococcus neoformans were used for identification of Cryptococcus neoformans. Four groups of mice were lethally infected with standard strain, Wuhan strain, American B-2643 strain and Var. Shanghainesis of the Cryptococcus neoformans. The samples collected included mice brain, lung, kidney, liver, small intestine tissue and were observed under a light microscope. More than 600 images of the fungus were input into a microcomputer. A system of computer for automatic identification of the Cryptococcus neoformans was developed. The technique involved image preprocessing, image segmenting, coding of line-length on the edge, curve fitting, extracting of image feature, building of image library and feature data bank etc.. And then, 768 images of the clinical samples and other fungus samples whose morphological features tend to be confused with Cryptococcus neoformans were input into microcomputer and subjected to automatic identification. The Cryptococcus neoformans was accurately identified within 15 min, and the consistency rate with results of routine culture was 98%.

Animals↗

Automatic record keeping in anaesthesia--a nine-year Italian experience.

In 1986, in Buccheri La Ferla Hospital, Palermo, an anaesthesia information management project was started. Its aim was to develop a computerized anaesthesia workstation. Today, the system is in daily clinical use and has reached most of its original goals: Automatic collection of physiological signals and patient monitor trends is possible by means of analog-digital conversion or by using serial data transfer. A centralized display is included in the system to allow easy control of the progress of the anaesthetic procedures in the hospital. Available in the workstation, there is an on-line help function to assist pharmacological calculations and administration of anaesthesia drugs. Mail messages can be sent to different anaesthesia workstations and data can be shared between them. Information collected during preoperative visits is automatically transferred from a portable personal computer to the system. There is a nine-year patient data-base with both preoperative and perioperative anaesthesia information which can be accessed from each of the workstations. Today, the system is in daily routine use and comprises eight anaesthesia workstations and two portable personal computers used for preoperative visits. The operation schedule with anaesthetists' notes is printed both for surgical wards and for O.R., using information stored from preoperative visits to the system. For automated data collection a trend resolution of one minute has been used. The postoperative orders are printed from the system in the recovery room and given to the wards with the patient. The feedback from the seventeen anaesthetists and twenty-four nurses who use the system routinely is positive. Today, 16,000 patient records are available in the database. This number increases by 3,300 every year. With increasing computer utilization in patient treatment there have been no legal or administrative controversies. Based on nine years' experience, it is clear that the use of computers in anaesthesia practice improves quality of patient care.

Analog-Digital Conversion↗

Automatic adjustment of contrast and brightness of magnetic resonance images.

Two statistics of the magnetic resonance (MR) image, the median and the standard deviation of the values of the significant pixels, can be used along with the type of image to adjust the contrast and brightness of the image (ie, to "window" it) automatically and robustly. The essential parts of this approach to automatic windowing are (1) avoidance of irrelevant pixels, (2) identification of the type of MR image from information stored in the image header, and (3) use of algorithms for the maximum and minimum values that reflect the preference of the intended viewer using a specific monitor and ambient lighting conditions for the different types of images. An evaluation in thirteen clinical studies yielded 91.5% (2312/2526) images requiring no further adjustment and the remaining 8.5% (214/2526) being improved by further adjustment.

Algorithms↗

Automatic segmentation, tissue characterization, and rapid diagnosis enhancements to the computed tomographic colonography analysis workstation.

An image processing system developed to support examination of computed tomographic colonoscopy (CTC) was developed in 1995. The clinical viability of CTC is enhanced by the solution of several technical problems. These problems include the limited detectability of sessile polyps and difficulties in discrimination between polypoid masses and retained stool. CTC is also made more feasible by simplifying the required colon preparation and reducing the time required to analyze scan results. Each of these challenges have been addressed by enhancements to the CTC analysis workstation software. Endoluminal volume rendering has been enhanced by the addition of automatic segmentation to facilitate analysis of colon segments, which contain tagged liquid stool. By automating this function, the system is able to process scans that are acquired following a wide variety of colon preparation protocols. Similar approaches have been used to identify retained stool. Automatic tissue characterization has also been incorporated into the volume rendering routines to help identify and diagnose polypoid masses. These enhancements have improved the quality of CTC interpretation, while reducing the time required to perform the analysis. This time reduction was necessary to reduce the cost of CTC enough to make it viable for asymptotic population screening. To date, over 150 patient examinations have been performed using this new technique. A recent blinded, prospective study reporting the results from two independent observers has been presented. The technique is feasible, reliable, and has been implemented clinically with results reported within 1 hour of the examination.

Colon↗

An algorithm for automatic segmentation and classification of magnetic resonance brain images.

In this article, we describe the development and validation of an automatic algorithm to segment brain from extracranial tissues, and to classify intracranial tissues as cerebrospinal fluid (CSF), gray matter (GM), white matter (WM) or pathology. T1 weighted spin echo, dual echo fast spin echo (T2 weighted and proton density (PD) weighted images) and fast Fluid Attenuated Inversion Recovery (FLAIR) magnetic resonance (MR) images were acquired in 100 normal patients and 9 multiple sclerosis (MS) patients. One of the normal studies had synthesized MS-like lesions superimposed. This allowed precise measurement of the accuracy of the classification. The 9 MS patients were imaged twice in one week. The algorithm was applied to these data sets to measure reproducibility. The accuracy was measured based on the synthetic lesion images, where the true voxel class was known. Ninety-six percent of normal intradural tissue voxels (GM, WM, and CSF) were labeled correctly, and 94% of pathological tissues were labeled correctly. A low coefficient of variation (COV) was found (mean, 4.1%) for measurement of brain tissues and pathology when comparing MRI scans on the 9 patients. A totally automatic segmentation algorithm has been described which accurately and reproducibly segments and classifies intradural tissues based on both synthetic and actual images.

Algorithms↗

Practice modifies the developing automatic postural response.

The purpose of this study was to examine effects of experience with a postural task on components of the automatic postural response including: (1) probability of activation of functionally appropriate postural muscles; (2) number of functionally appropriate postural muscles activated; and (3) onset latencies of functionally appropriate postural muscles in infants. Infants (n=15; age 36-48 weeks old) able to pull themselves into a standing position but not able to walk independently were tested using a postural task requiring the infant to stand and balance, with support, following a forward or backward movement of the support surface (platform perturbation). Infants were tested twice at 5-day intervals. One-half of the infants, the training group, were given intense platform perturbation training on the days between test sessions. Infants in the second group were also brought into the laboratory on the days between test sessions but were not exposed to platform perturbations during those days. Electromyograms of six leg and trunk muscles were recorded during test sessions to provide muscle onset latencies, probability of muscle activation data, and the number of postural muscles activated following a perturbation. Training infants demonstrated significant increases in probability of activating functionally appropriate muscles with tibialis anterior, quadriceps, and abdominal muscles activated in response to backward sway and gastrocnemius muscle in response to forward sway. The number of functionally appropriate postural muscles activated in a single trial also increased in the training group. There were no significant changes in mean postural muscle onset latencies or number of trials with antagonist muscle coactivation for either training or control groups. These findings suggest that during development selective parameters of the automatic postural response are affected by experience with the postural task.

Child Development↗

[Tissue sampling in the deep head-neck area with a new ultrasound-controlled, semi-automatic micro-punch biopsy device].

Fine needle aspiration biopsy (FNAB) under ultrasound control is an established diagnostic procedure for the head and neck region. Because of the disintegration of tissues, the diagnostic value of the method is limited resulting in only moderate specificity. In a prospective study, we performed a new, semi-automatic biopsy method in patients who had been diagnosed with sonographically confirmed pathologic masses in the head-neck region. This biopsy is carried out with a spring-loaded biopsy pistol which uses a disposable 20-gauge, specially designed cutting needle. Because this method combines the low invasiveness of FNAB with the high specificity of an excisional biopsy, a high tissue quality is obtained. Comparing these bioptic results with those of subsequent excisional biopsies proves that this new method yields a sensitivity of close to 100% for the detection of lymph node metastases of squamous cell carcinomas (SCC). The tissue cylinders have a reproducible size and allow ultrastructural investigations in the transmission electron microscope (TEM) on the ultrastructural level. Due to the excellent tissue preservation in the biopsy cylinders, ultrastructural studies, using transmission electron microscopy, may be carried out with the biopsy material. Furthermore, following paraffin embedding of biopsy cylinders, serial sections may be obtained for special staining techniques, and immunohistological investigations are possible which may serve as an adjunct in the diagnosis of, e.g., lymphoproliferative lesions with a sensitivity of 96%. Summarizing, the new semi-automatic biopsy technique obtains tissue probes of high quality with low invasiveness which enables highly sensitive diagnosis of head and neck lesions.

Biopsy, Needle↗

[Added work of breathing, respiratory pattern and determination of ventilator weaning readiness in inspiratory pressure support and and automatic tube compensation].

We measured the ventilatory pattern and additional work of breathing (WOBadd) at three different levels of inspiratory pressure support [IPS 5, 10, 15 mbar above positive end-expiratory pressure (PEEP)] and in a new ventilatory mode, automatic tube compensation (ATC), in nine operative patients without lung injury nine patients ventilated for several following acute respiratory insufficiency (ARI). In ATC, endotracheal tube resistance is compensated automatically by means of closed-loop control of the calculated tracheal pressure. Pressure support in this mode, i.e. airway pressure above PEEP, is equal to the actual flow-dependent pressure drop across the endotracheal tube (ETT). Airway pressure rises at the beginning of inspiration and falls towards the end. As the tube resistance of ETT seriously hinders expiration and can cause desynchronization between ventilator and patient, airway pressure is reduced below PEEP during expiration in the same way as it is increased during inspiration. The result is a near-constant tracheal pressure at PEEP both during inspiration and during expiration. This mode could be best termed as "electronic extubation". The most striking difference between the postoperative patients and the ARI patients was their minute ventilation (17.8 +/- 1.85 l/min in ARI patients vs 7.3 +/- 3.1 l/min in the postoperative patients). In the postoperative patients augmentation of IPS from 5 to 15 mbar induced a steady increase in tidal volume (VT) and a consecutive decrease in respiratory rate (rr) compared with ATC (VTATC,postop = 463 +/- 78 ml; rrATC,postop = 16 +/- 4 min-1; VTIPS5.postop = 505 +/- 79 ml; rrIPS5,postop = 15 +/- 4 min-1; VTIPS10,postop = 562 +/- 86 ml; rrIPS15,postop = 14 +/- 4 min-1; VTIPS15.postop = 660 +/- 151 ml; rrTPS15,postop = 12 +/- 4 min-1), whereas the augmentation of IPS of 5 and 10 mbar in the ARI patients could not compensate for the increase in rr and the decrease in VT, after switching from ATC to IPS (VTATC,ARI 724 +/- 308 ml, rrATC,ARI = 24 +/- 6 min-1; VTIPS5,ARI = 649 +/- 315 ml; rrIPS5,ARI = 27 +/- 8 min-1; VTIPS10,ARI = 653 +/- 353 ml; rrIPS10,ARI = 25 +/- 8 min-1: Even IPS 15 was not able to reestablish VT at the values observed during ATC (VTIPS15,ARI = 680 +/- 312 ml). During ATC WOBadd was small in both postoperative and ARI patients (WOBadd,ATC,postop = 93 +/- 36 mJ/l, WOBadd,ATC,ARI = 116 +/- 72 mJ/l). In the postoperative patients, an inspiratory pressure support of 5 mbar was not sufficient to compensate WOBadd compared with ATC. However, IPS 10 and 15 mbar were able to compensate for WOBadd (WOBadd,ATC5.postop WOBadd,IPS5,postop = 189 +/- 77 mJ/l; WOBadd,IPS10,postop = 55 +/- 30 mJ/l; WOBadd,IPS15,postop = 21 +/- 11 mJ/l). In the ARI patients an IPS 5, 10 or 15 mbar was not sufficient to compensate for WOBadd (WOBadd,IPS 5,ARI = 1126 +/- 262 mJ/l; WOBadd,IPS 10,ARI 863 +/- 253 mJ/l; WOBadd,IPS15,ARI 763 +/- 298 mJ/l). Under ATC, WOBadd was only 15% of WOBadd under IPS of 15 mbar. All but two patients were successfully extubated after the investigation. These two patients were not extubated because they were dependent on an FIO2 > 0.5. Our results strongly indicate that ventilatory dependence in ARI patients may be caused by the ETT rather than by mechanical dysfunction of the lung. ATC is a very helpful mode to use in distinguishing between ventilatory failure caused by ETT and real ventilatory dependence.

Adult↗

Effects of patient-triggered automatic switching between mandatory and supported ventilation in the postoperative weaning period.

OBJECTIVE: To compare two ventilator settings in the postoperative weaning period. Patient-triggered automatic switching between controlled ventilation and supported spontaneous breathing (Automode, AM) was compared to synchronised intermittent mandatory ventilation (SIMV) with stepwise manual adjustment of mandatory frequency according to the breathing activity. DESIGN: Prospective clinical investigation. SETTING: Eighteen-bed intensive care unit in a university hospital. PATIENTS: Forty postoperative patients with healthy lungs who had undergone brain tumour surgery. INTERVENTIONS: Randomisation either to the AM or SIMV weaning procedure after entering the ICU. MEASUREMENTS AND RESULTS: Total weaning time and number of manipulations on the ventilator were observed. Cardiocirculatory and respiratory parameters were measured consecutively at five points during the weaning period. No significant differences were seen for cardiocirculatory parameters, airway pressures and oxygenation between the two groups. There was a trend to shorter weaning times with AM (136 +/- 46 min vs 169 +/- 68 min, n.s.), the average number of manipulations on the ventilator was lower (0.55 +/- 0.69 vs 5.05 +/- 1.19,p < 0.001) and arterial partial pressure of carbon dioxide (PaCO2) levels showed fewer variations in the late phase of the weaning period (39.5 +/- 3.1 vs 38.3 +/- 7.2, p < 0.001 for differences in variance). CONCLUSIONS: Automatic, patient-triggered switching between controlled and supported mode of ventilation can be used for postoperative weaning of neurosurgical patients with healthy lungs. Compared to a SIMV weaning procedure, fewer manipulations on the ventilator are necessary and individual adaptation of ventilation seems to be more accurate.

Adult↗

Automatic and imperative motor activations in stimulus-response compatibility: magnetoencephalographic analysis of upper and lower limbs.

The stimulus-response (S-R) compatibility effect refers to the difference in performance due to the spatial S-R relationship in choice reaction time. We investigated the mechanism of neural activities in S-R compatibility at the level of the primary motor cortices for upper and lower limbs responses using magnetoencephalography (MEG). In the S-R compatible task, subjects were required to respond on the same side of the stimulus light using either an upper or lower limb. In the incompatible task, subjects were required to respond in the reverse manner. Premotor times of upper and lower limbs were faster for the compatible response than for the incompatible response. The neuromagnetic brain activities related to response execution were estimated using a multi-dipole model. Stimulus-locked MEG indicated that the current moments of motor dipoles for both effectors occurred bilaterally and reached the first peak at a constant delay irrespective of whether the task was compatible or incompatible. This indicates that the neural activation of the primary motor cortex is automatically synchronized with the stimulus onset. Response-locked MEG showed that the peak current moment of the motor dipole contralateral to the response was stronger for the compatible task than for the incompatible one regardless of whether the responses were made using the upper or lower limbs. The MEG results suggest that automatic motor activation facilitates imperative motor activation for a compatible response, whereas it is not sufficient to prime imperative motor activation for an incompatible response.

Adult↗

Are automatic postural responses in patients with Parkinson's disease abnormal due to their stooped posture?

Abnormal automatic postural responses are thought to contribute to balance impairment in Parkinson's disease. However, because postural responses are modifiable by stance, we have speculated that some postural abnormalities in patients with Parkinson's disease are secondary to their stooped stance. We have studied this assumption by assessing automatic postural responses in 30 healthy subjects who were instructed either to stand upright or to assume a typical parkinsonian posture. During both conditions, subjects received 20 serial 4 degrees 'toe-up' rotational perturbations from a supporting forceplate. We recorded short-latency (SL) and medium-latency (ML) responses from stretched gastrocnemius muscles and long-latency (LL) responses from shortened tibialis anterior muscles. We also assessed changes in the center of foot pressure (CFP) and the center of gravity (COG). The results were qualitatively compared to a previously described group of patients with Parkinson's disease who, under these circumstances, typically have large ML responses, small LL responses and insufficient voluntary postural corrections, accompanied by a slow rate of backward CFP displacement and an increased posterior COG displacement. The stooped posture resulted in unloading of medial gastrocnemius muscles and loading of tibialis anterior muscles. Onset latencies of stretch responses in gastrocnemius muscles were delayed in stooped subjects, but the onset of LL responses was markedly reduced. Amplitudes of both ML and LL responses were reduced in stooped subjects. Prestimulus COG and, to a lesser extent, CFP were shifted forwards in stooped subjects. Posterior COG displacement and the rate of backward CFP displacement were diminished in stooped subjects. Voluntary postural corrections were unchanged while standing stooped. These results indicate that some postural abnormalities of patients with Parkinson's disease (most notably the reduced LL responses) can be reproduced in healthy subjects mimicking a stooped parkinsonian posture. Other postural abnormalities (most notably the increased ML responses and insufficient voluntary responses) did not appear in stooped controls and may contribute to balance impairment in Parkinson's disease.

Adult↗

Evaluation and development of automatic two-dimensional measurements of histomorphometric parameters reflecting trabecular bone connectivity: correlations with dual-energy x-ray absorptiometry and quantitative ultrasound in human calcaneum.

In osteoporosis, bone fragility results from both bone loss and changes in trabecular microarchitecture, which can be quantified by bone histomorphometric parameters. Twenty human calcaneum were collected after necropsy. All measurements were performed at the same anatomical location. Bone histomorphometric parameters were measured on histological slides with an automatic image analyzer. The aims of our study were (1) to develop automatic measurements of four additional parameters reflecting trabecular network connectivity and complexity, i.e., trabecular bone pattern factor (TBPf), Euler number/tissue volume (Euler) according to the three definitions previously reported and to a fourth one established in the laboratory (Euler(strut.cavity)), marrow star volume, and interconnectivity index, and to determine their usefulness in microarchitecture characterization; and (2) to validate these parameters by evaluating their relationship with dual-energy X-ray absorptiometry and quantitative ultrasound (QUS) measurements performed on the same samples. The statistical analysis showed that TBPf and Euler(strut.cavity) appeared to be the most significant connectivity parameters, independently of bone quantity (bone mineral density, apparent density, cancellous bone volume). For QUS, after adjustment for bone quantity, only speed of sound (SOS) was significantly and negatively correlated to Euler(strut.cavity). Broadband ultrasound attenuation depends only on bone quantity. In conclusion, TBPf (a strut analysis parameter extrapolable in three dimensions) and Euler(strut.cavity) (the only bone connectivity parameter reflecting SOS) are two valid bone microarchitecture parameters. These new parameters were significantly correlated to the established trabecular structure parameters: trabecular thickness or trabecular spacing, being weakly correlated with SOS.

Absorptiometry, Photon↗

Automatic segmentation of dynamic neuroreceptor single-photon emission tomography images using fuzzy clustering.

The segmentation of medical images is one of the most important steps in the analysis and quantification of imaging data. However, partial volume artefacts make accurate tissue boundary definition difficult, particularly for images with lower resolution commonly used in nuclear medicine. In single-photon emission tomography (SPET) neuroreceptor studies, areas of specific binding are usually delineated by manually drawing regions of interest (ROIs), a time-consuming and subjective process. This paper applies the technique of fuzzy c-means clustering (FCM) to automatically segment dynamic neuroreceptor SPET images. Fuzzy clustering was tested using a realistic, computer-generated, dynamic SPET phantom derived from segmenting an MR image of an anthropomorphic brain phantom. Also, the utility of applying FCM to real clinical data was assessed by comparison against conventional ROI analysis of iodine-123 iodobenzamide (IBZM) binding to dopamine D2/D3 receptors in the brains of humans. In addition, a further test of the methodology was assessed by applying FCM segmentation to [123I]IDAM images (5-iodo-2-[[2-2-[(dimethylamino)methyl]phenyl]thio] benzyl alcohol) of serotonin transporters in non-human primates. In the simulated dynamic SPET phantom, over a wide range of counts and ratios of specific binding to background, FCM correlated very strongly with the true counts (correlation coefficient r2>0.99, P<0.0001). Similarly, FCM gave segmentation of the [123I]IBZM data comparable with manual ROI analysis, with the binding ratios derived from both methods significantly correlated (r2=0.83, P<0.0001). Fuzzy clustering is a powerful tool for the automatic, unsupervised segmentation of dynamic neuroreceptor SPET images. Where other automated techniques fail completely, and manual ROI definition would be highly subjective, FCM is capable of segmenting noisy images in a robust and repeatable manner.

Animals↗

Automatic detection of ground glass opacities on lung HRCT using multiple neural networks.

The purpose of this study was to implement neural networks and expert rules for the automatic detection of ground glass opacities (GG) on high-resolution computed tomography (HRCT). Different approaches using self-organizing neural nets as well as classifications of lung HRCT with and without the use of explicit textural parameters have been applied in preliminary studies. In the present study a hybrid network of three single nets and an expert rule was applied for the detection of GG on 120 HRCT scans from 20 patients suffering from different lung diseases. Single nets alone were not capable to reliably detect or exclude GG since the false-positive rate was greater than 100 % with regard to the area truly involved, more than 50 pixels throughout, and the true-positive rate was greater than 95 %. The hybrid network correctly classified 91 of 120 scans. Mild GG was false positive in 15 cases with less than 50 pixels, which was judged not clinically relevant. The pitfalls were: partial volume effects of bronchovascular bundles and the chest wall. Motion artefacts and diaphragm were responsible for 11 misclassifications. Hybrid networks represent a promising tool for an automatic pathology-detecting system. They are ready to use as a diagnostic assistant for detection, quantification and follow-up of ground glass opacities, and further applications are underway.

Expert Systems↗

Automatic speaking valve in speech rehabilitation for laryngectomized patients.

For speech rehabilitation after total laryngectomy, the Provox FreeHands Heat and Moisture Exchanger (FreeHands HME; Atos Medical AB, Hörby, Sweden) was compared with the Provox Heat and Moisture Exchanger (HME), and the patients' Health-Related Quality of Life (HRQoL) was assessed. A review of the English literature was performed considering automatic speaking valves. The study design was a cohort study. Fourteen laryngectomized male patients who had used the HME successfully before receiving the FreeHands HME entered the study. An ENT specialist and a speech pathologist examined these patients. Data concerning voicing, breathing, skin adhesion, voice and speech quality, and HRQoL were collected by a structured questionnaire. Voice recordings were performed for evaluation of the quality of the voice. A computer-aided search of the MED-LINE database was conducted, supplemented by hand searches of key journals. Twelve patients had used the FreeHands HME on special social occasions and reported three main reasons why FreeHands HME was unsuitable for continuous use: heavier breathing, more difficult speaking, and worse subjective quality of voice. With HME, phonation time tended to be longer and the softest phonation softer ( P =0.034). The loudest phonation was louder with FreeHands HME ( P =0.015). Patients' HRQoL assessed by the 15D profile was similar to that of the age- and sex-matched male Finnish general population (patients 0.877, population 0.884). A review of the literature showed few works dealing with automatic speaking valves. The FreeHands HME is a useful additional device in a selected group of laryngectomized patients. Total laryngectomy did not lower patients' HRQoL notably.

Adult↗

Atrial automaticity and atrioventricular conduction in athletes: contribution of autonomic regulation.

Little is known about the sinoatrial automatism and atrioventricular conduction of trained individuals who present a normal resting electrocardiogram. We used transesophageal atrial stimulation, a minimally invasive technique, to evaluate aerobically trained athletes (n = 10) and sedentary individuals (n = 10) with normal resting electrocardiograms, to test the hypothesis that parasympathetic tone, as detected by heart rate variability, could be associated with changes in sinoatrial automatism and atrioventricular conduction. Corrected sinus node recovery time tended to be longer in athletes than in sedentary individuals, but this difference did not reach statistical significance. The Wenckebach point occurred at a lower rate in athletes than in the controls. Over a 24-h period of measurement, the mean RR interval was longer in the athletes than in the sedentary individuals. The mean square root of successive differences (rMSSD) tended to be higher in athletes than in controls, but this difference did not reach statistical significance. There was a moderate correlation (r = 0.48, P < 0.05) between the index of atrioventricular conduction, the rate at the Wenckebach point, and the logarithmically transformed rMSSD. Thus, as a corollary to its effects on the sinus node, where increased parasympathetic tone, decreased sympathetic tone, and non-autonomic components may contribute to sinus bradycardia, it is possible that athletic training may also induce intrinsic adaptations in the conduction system, which could contribute to the higher prevalence of atrioventricular conduction abnormalities observed in athletes.

Adult↗