Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

The use of pencil lead as a matrix and calibrant for matrix-assisted laser desorption/ionisation.

Pencil lead is shown to be an effective matrix and calibrant in matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry. Various groups of analytes, including peptides, polymers and actinide metals, can be readily ionised using MALDI when deposited onto a pencil lead matrix. The matrix is seen to have advantages in sample preparation relating to its hydrophobic properties and almost complete suppression of the matrix during analysis. Using pencil lead as a matrix is a quick and convenient method of qualitative analysis and has been shown to be quantitative for the isotope ratio analysis of actinide metals.

Actinoid Series Elements↗

Large-scale purification of myeloperoxidase from HL60 promyelocytic cells: characterization and comparison to human neutrophil myeloperoxidase.

A large-scale purification procedure was developed for the isolation of myeloperoxidase from HL60 promyelocytic cells in culture. Initial studies showed the bulk of peroxidase-positive myeloperoxidase activity to be located in the cetyltrimethylammonium bromide solubilized particulate fraction of cell homogenates. The myeloperoxidase was then chromatographically purified using concanavalin A followed by gel filtration. SDS-PAGE analysis of the final preparation showed the presence of only two proteins with molecular masses of approximately 55 and 15 kDa, corresponding to the large and small subunits of myeloperoxidase. These data, along with Reinheit Zahl (RZ) values (A(430)/A(280)) of greater than or equal to 0.72, indicate that the myeloperoxidase prepared by this method is apparently homogeneous. Preparations routinely yielded 12-20 mg of pure myeloperoxidase per 10 ml of cell pellet. The HL60 myeloperoxidase was shown to be indistinguishable from purified human neutrophil myeloperoxidase by size exclusion chromatography, analytical ultracentrifugation, SDS-PAGE, Western blot, and NH(2)-terminal sequence analysis. The activities of the two myeloperoxidase samples, as measured using either the tetramethylbenzidine or the taurine chloramine assay, were indistinguishable. Finally, both enzymes responded identically to dapsone and aminobenzoic acid hydrazide, known inhibitors of myeloperoxidase. A protocol is presented here for the rapid, large-scale purification of myeloperoxidase from cultured HL60 cells, as well as evidence for the interchangeability of this myeloperoxidase and that purified from human neutrophils.

Benzidines↗

Simultaneous analysis of diphenylmethoxyacetic acid, a metabolite of diphenhydramine, and its deuterium-labeled stable isotope analog in ovine plasma and urine.

Diphenylmethoxyacetic acid (DPMA) is a major metabolite of diphenhydramine in monkeys, dogs, and humans. The metabolic fate of diphenhydramine (DPHM) in sheep is not yet well understood; however, preliminary studies have demonstrated the presence of DPMA in the plasma and urine of sheep following an intravenous bolus of DPHM. Our current studies employ the simultaneous intravenous co-administration of DPHM and the stable isotope analog of DPHM to investigate the pharmacokinetics of DPHM in sheep. In these studies, in order to investigate the pharmacokinetics of the DPMA metabolite, measurement of both unlabeled and stable-isotope labeled DPMA is required. Thus, a stable isotope analog of DPMA ([2H10]DPMA) was synthesized, characterized, and purified for use as an analytical standard. The quantitative method for the gas chromatography-electron-impact mass spectrometry (GC-EI-MS) analysis of DPMA and [2H10]DPMA used a single step liquid-liquid extraction procedure using toluene for sample cleanup. The samples were derivatized with N-methyl-N-(tert.-butyldimethylsilyl) trifluoroacetamide. A 1.0-microliter aliquot of the prepared sample was injected into the GC-MS system and quantitated using selected-ion monitoring (SIM). One ion was monitored for each compound, namely, m/z 165 for the internal standard diphenylacetic acid, m/z 183 for DPMA, and m/z 177 for [2H10]DPMA. The ion chromatograms were free from chromatographic peaks co-eluting with the compound of interest. The calibration curve was linear from 2.5 ng/ml (limit of quantitation) to 250.0 ng/ml in both urine and plasma. The intra-day and inter-day variabilities of this assay method were within acceptable limits (below 20% at the limit of quantitation and below 10% at all other concentrations). This method was used to measure the concentration of DPMA and [2H10]DPMA in plasma and urine samples from a ewe in which equimolar amounts of DPHM and [2H10]DPHM were administered by an intravenous bolus dose via the femoral vein. DPMA appeared to persist longer in the plasma and the urine as compared to DPHM. This method is robust and reliable for the quantitation of DPMA and [2H10]DPMA in biological samples obtained from sheep (e.g. plasma and urine).

Acetates↗

Dispersive solid-phase extraction for the determination of sulfonamides in chicken muscle by liquid chromatography.

A new, fast and low-cost sample preparation for the determination of sulfonamide (SA) residues in chicken muscle by LC technique has been developed. The procedure involves single extraction of sample with acetonitrile, followed by a rapid clean-up and was called "dispersive solid-phase extraction" (dispersive SPE). Using dispersive SPE 25 mg of octadecyl sorbent was added to 1 ml of acetonitrile extract, mixed and centrifuged. The acetonitrile layer was evaporated and residue was dissolved in acetate buffer (pH 3.5). Analysed compounds were detected by fluorescence detector after pre-column derivatization with fluorescamine. The separation of analytes was performed with gradient elution with mobile phase methanol: 2% acetic acid and RP-LC analytical column. The whole procedure was evaluated for six sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfametoxypirydazine, sulfametoxazole and sulfadimetoxine) according to the European Commission Decision 2002/657/EC. Specificity, decision limit (CCalpha), detection capacity (CCbeta), trueness and precision were determined during validation process. The dispersive SPE with octadecyl sorbent was found suitable for sample preparation before sulfonamide determination in chicken muscle. As it was found the most of endogenous matrix components were removed and the analytes were isolated from spiked samples with recoveries above 90%. The used analytical conditions allow to successively separate all the tested sulfonamides with the limit of detection at the level of 1-5 microg/kg. The method is simple, rapid and more effective than conventional methods.

Animals↗

Batch immunoextraction method for efficient purification of aromatic cytokinins.

A range of benzylaminopurines naturally occur in plants and exhibit high biological activity. Others have been synthesized, such as 6-(2-hydroxy-3-methoxybenzylamino)purine riboside (2OH3MeOBAPR), which has shown interesting anti-cancer activity under in vitro conditions. In order to study the biological activity of this interesting compound in more detail, a rapid and highly efficient method for its purification from complex samples (e.g. blood and plant extracts) is needed. Therefore, we prepared monoclonal antibodies against 2OH3MeOBAPR. The antibody had undetectable cross-reactivity with all natural isoprenoid cytokinins, but relatively high cross-reactivity with aromatic cytokinins as well as some synthetic di- and tri-substituted 6-benzylaminopurines and the corresponding ribosides. The antibody also showed strong responses and specificity in enzyme-linked immunoassays (ELISAs). In addition, it was used to prepare, for the first time, an immunoaffinity sorbent with high specificity and capacity for aromatic cytokinins. A batch immunoextraction method was then developed and optimized for the purification of 2OH3MeOBAPR from murine blood samples. The high efficacy and simplicity of this method (in off-line combination with HPLC-MS) for the isolation of target analytes from biological material is demonstrated in this study.

Animals↗

Ethanol analysis from biological samples by dual rail robotic autosampler.

Detection, identification, and quantitation of ethanol and other low molecular weight volatile compounds in liquid matrices by headspace gas chromatography-flame ionization detection (HS-GC-FID) and headspace gas chromatography-mass spectrometry (HS-GC-MS) are becoming commonly used practices in forensic laboratories. Although it is one of the most frequently utilized procedures, sample preparation is usually done manually. Implementing the use of a dual-rail, programmable autosampler can minimize many of the manual steps in sample preparation. The autosampler is configured so that one rail is used for sample preparation and the other rail is used as a traditional autosampler for sample introduction into the gas chromatograph inlet. The sample preparation rail draws up and sequentially adds a saturated sodium chloride solution and internal standard (0.08%, w/v acetonitrile) to a headspace vial containing a biological sample, a calibrator, or a control. Then, the analytical rail moves the sample to the agitator for incubation, followed by sampling of the headspace for analysis. Using DB-624 capillary columns, the method was validated on a GC-FID and confirmed with a GC-MS. The analytes (ethanol, acetonitrile) and possible interferences (acetaldehyde, methanol, pentane, diethyl ether, acetone, isopropanol, methylene chloride, n-propanol, and isovaleraldehyde) were baseline resolved for both the GC-FID and GC-MS methods. This method demonstrated acceptable linearity from 0 to 1500 mg/dL. The lower limit of quantitation (LOQ) was determined to be 17 mg/dL and the limit of detection was 5 mg/dL.

Biomarkers↗

Electron-probe X-ray microanalysis of individual particles of solid snow sediment with size factor correction.

A technique is proposed for X-ray electron-probe microanalysis (EPMA) of individual particles of solid snow sediment. Two sample preparation procedures were used to analyze the sediments. The PAP-method and the original bi-exponential model were used for matrix correction and the calculation of elemental composition. A method of calculating composition has been developed for approximately spherical individual particles, comparable in size with an area of X-ray generation. An analytical expression is proposed for determining the composition of these particles, taking account of their size. Including the size factor reduces the error of composition determination from 0.5-45 to 0.2-22% relative percent, for particles in the size range 1-3 microm.

Journal Article↗

Differentiation of spores of Bacillus subtilis grown in different media by elemental characterization using time-of-flight secondary ion mass spectrometry.

We demonstrate the use of time-of-flight secondary ion mass spectrometry (TOF-SIMS) in a forensics application to distinguish Bacillus subtilis spores grown in various media based on the elemental signatures of the spores. Triplicate cultures grown in each of four different media were analyzed to obtain TOF-SIMS signatures comprised of 16 elemental intensities. Analysis of variance was unable to distinguish growth medium types based on 40Ca-normalized signatures of any single normalized element. Principal component analysis proved successful in separating the spores into groups consistent with the media in which they were prepared. Confusion matrices constructed using nearest-neighbor classification of the PCA scores confirmed the predictive utility of TOF-SIMS elemental signatures in identifying sporulation medium. Theoretical calculations based on the number and density of spores in an analysis area indicate an analytical sample size of about 1 ng, making this technique an attractive method for bioforensics applications.

Bacillus subtilis↗

[The review of the European Union documents relating to contamination of aflatoxins in food].

In the following review, Polish and European Union legislation, concerning maximum level of aflatoxins in foodstuffs, was reported. In this moment, no specific requirements exist but according to Food and Nutrition Law all kind of food ought to be free from aflatoxins. Practically, maximum aflatoxins level should be below the detection limit of official analytical method (thin layer chromatography)--5 micrograms/kg and 0.05 microgram/l for milk. Commission Directive 98/53/EC laying down the sampling methods and the methods of analysis for aflatoxins in foodstuffs and Commission Regulation No 152/98 setting maximum levels for aflatoxins in foodstuffs were presented. Also, Ministry of Health Draft Regulation, concerning maximum levels of contamination in food is prepared in accordance with EU regulation, was reported.

Aflatoxins↗

Enzyme-linked immunosorbent assay for microcystins in blue-green algal blooms.

A direct competitive enzyme-linked immunosorbent assay (ELISA) for the freshwater blue-green algal toxin microcystin (MCYST) in algae and water was developed. The assay involves coating anti-MCYST-variant leucine-arginine (LR) antibody to the ELISA plate and the use of MCYST-LR-peroxidase as the enzyme marker. The linear portion of the standard curve for MCYST in phosphate buffer containing saline (PBS) was 0.5-10.0 ng/mL (25-500 pg/assay). The minimum detection level for MCYST-LR was 0.20 ng/mL (10 pg/assay). Contaminated water could be directly used in the ELISA. The overall analytical recoveries for MCYST-LR added to water at levels of 1-20 ng/mL was 83.4%. For analysis of cellular MCYST, the toxin was first extracted from the algae with 0.1M ammonium bicarbonate, diluted with PBS to less than 0.5 mg dried algae/mL (less than 5.0 mg wet weight/mL) and directly used in the ELISA. C-18 reverse-phase Sep-Pak cartridges effectively adsorbed MCYST from the toxin-containing solutions. The toxin could be recovered from the cartridge by eluting with 60% methanol. Using this approach, an algae extract that was relatively free of MCYST was prepared and was used in a recovery study. The overall analytical recovery of MCYST added to the algae extract in the range of 0.25-20 ppm was 83% with a coefficient of variation of 11.9%. The detection limit for MCYST in dried algae was about 0.25-0.5 microgram/g (0.25-0.5 ppm) lyophilized algae sample. This method was applied for the analysis of several naturally occurring algal blooms. Limited samples were also analyzed for MYCST by liquid chromatography.(ABSTRACT TRUNCATED AT 250 WORDS)

Chromatography, Liquid↗

The development of an air sampling and analytic method for o-phenylenediamine in an industrial environment.

A new method for monitoring o-phenylenediamine (OPD) in the industrial environment was developed. Some aromatic amines such as OPD are difficult to collect and analyze directly because they are sensitive to oxidation. The method developed overcomes this difficulty by derivatizing the OPD directly upon collection. The OPD vapor is drawn through a bubbler containing acetic anhydride to form the relatively stable 1,2-diacetamidobenzene. The acetic anhydride solution is analyzed by means of high performance liquid chromatography (HPLC), and the diacetamido derivative quantified. The analysis is linear for standard solutions in the range of 0.5 microgram/mL to over 0.5 mg/mL. Air concentrations of OPD were prepared by passing a metered stream of nitrogen through a class tube packed with OPD crystals and diluting the stream with a metered air stream to achieve the desired level. The collection efficiency and conversion of OPD to the derivative was found to approach 100% at vapor concentrations of 0.09 mg/m3 but was reduced to about 60% at 0.02 mg/m3. The poor recovery at low concentrations appeared to be at least in part due to wall adsorption. Moisture had little effect on sample collection and analysis. O-Toluenediamine, chemically similar to OPD, was found to interfere in the analysis.

Absorption↗

Stabilization of 10-hydroxycamptothecin in poly(lactide-co-glycolide) microsphere delivery vehicles.

PURPOSE: The purpose of this study was to investigate the potential of poly(lactide-co-glycolide) (PLGA) microspheres to stabilize and deliver the analogue of camptothecin, 10-hydroxycamptothecin (10-HCPT). METHODS: 10-HCPT was encapsulated in PLGA 50:50 microspheres by using an oil-in-water emulsion-solvent evaporation method. The influence of encapsulation conditions (i.e., polymer molecular weight (Mw), polymer concentration, and carrier solvent composition) on the release of 10-HCPT from microspheres at 37 degrees C under perfect sink conditions was examined. Analysis of the drug stability in the microspheres was performed by two methods: i) by extraction of 10-HCPT from microspheres and ii) by sampling release media before lactone--carboxylate conversion could take place. RESULTS: Microspheres made of low Mw polymer (inherent viscosity 0.15 dl/g) exhibited more continuous drug release than those prepared from polymers of higher Mw (i.v. = 0.58 and 1.07 dl/g). In addition, a high polymer concentration and the presence of cosolvent in the carrier solution to dissolve 10-HCPT were both necessary in the microsphere preparation in order to eliminate a large initial burst of the released 10-HCPT. An optimal microsphere formulation released 10-HCPT slowly and continuously for over two months with a relatively small initial burst of the released drug. Both analytical methods used to assess the stability of 10-HCPT revealed that the unreleased camptothecin analogue in the microspheres remained in its active lactone form (> 95%) over the entire 2-month duration of study. CONCLUSIONS: PLGA carriers such as those described here may be clinically useful to stabilize and deliver camptothecins for the treatment of cancer.

Antineoplastic Agents, Phytogenic↗

Evaluation of a rapid micro-scale assay for tacrolimus by liquid chromatography-tandem mass spectrometry.

BACKGROUND: The immunosuppressive drug tacrolimus has complex and unpredictable pharmacokinetics, therefore regular monitoring is required in patients receiving tacrolimus therapy. We have developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for measuring tacrolimus concentrations in whole blood and have compared it with a microparticle enzyme immunoassay. METHODS: For the LC-MS/MS assay, samples were prepared in a 96-deep well microtitre plate by adding 10 micro L of blood to 40 micro L of 0.1 mol/L zinc sulphate solution. Proteins were precipitated by adding 100 micro L acetonitrile containing ascomycin internal standard. After vigorous mixing and centrifugation, 20 micro L of the supernatant was injected into the LC-MS/MS system. A C18 cartridge (3 mm x 4 mm) was eluted with a step gradient of 50% to 100% methanol containing 2 mmol/L ammonium acetate and 0.1% (v/v) formic acid, at 0.6 mL/min. The column was maintained at 55 degrees C. RESULTS: The retention times were 0.98 min for ascomycin and 0.98 min for tacrolimus. Cycle time was 2.5 min, injection to injection. The analytes were monitored using a Quattro micro trade mark tandem mass spectrometer operated in multiple reaction monitoring mode using the following transitions: m/z821 > 768 (tacrolimus) and m/z809 > 756 (ascomycin). The limit of quantitation was 0.5 micro g/L and the assay was linear up to 30 micro g/L. Precision of the method, over the concentration range 2.5-15.0 micro g/L, was < 7% within-batch and < 6% between-batch. Total time to analyse 24 samples including result generation was 90 min. CONCLUSION: We conclude that the LC-MS/MS method is quick, precise and robust and will provide a fast turn around of results for the transplant physician.

Chromatography, High Pressure Liquid↗

Monitoring the neuropeptide metabolites by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

The developments of bio-analytical methods for analyzing bioactive peptides are of paramount importance. Neuropeptides and their bioactive fragments play a vital role in the regulation of many biological processes and diseases. This paper presents the use of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) method for monitoring neuropeptides along with their degradation products in plasma samples from cancer patients. The neuropeptides focused in this study were beta-endrophin, substance P, and bradykinin. The method involves the enzyme digestion of the neuroactive peptides followed by MALDI-MS sample preparation and subsequent acquisition of the MS spectral data. The mass spectral profile identifies most of the C-terminal and N-terminal peptides, and the mass accuracy was in the range of -1.68 to 1.46 Da with the mass spectrometer utilised. Analysis of the neuropeptide degradation patterns from the cancer patients were compared with the controls showed similar results. The study reveals that this approach can be used to identify the enzymatic digestion products of protein.

Bradykinin↗

Specific method for determination of gefitinib in human plasma, mouse plasma and tissues using high performance liquid chromatography coupled to tandem mass spectrometry.

A rapid, sensitive and specific method was developed and validated using liquid chromatography-tandem mass spectrometry (LC/MS/MS) for determination of gefitinib in human plasma and mouse plasma and tissue. Sample preparation involved a single protein precipitation step by the addition of 0.1 mL of plasma or a 200 mg/mL tissue homogenate diluted 1/10 in human plasma with 0.3 mL acetonitrile. Separation of the compounds of interest, including the internal standard (d8)-gefitinib, was achieved on a Waters X-Terra C18 (50 mm x 2.1 mm i.d., 3.5 microm) analytical column using a mobile phase consisting of acetonitrile-water (70:30, v/v) containing 0.1% formic acid and isocratic flow at 0.15 mL/min for 3 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 1-1000 ng/mL for the human plasma samples and 5-1000 ng/mL for mouse plasma and tissue samples with values for the coefficient of determination of > 0.99. The values for both within- and between-day precision and accuracy were well within the generally accepted criteria for analytical methods (< 15%). This method was subsequently used to measure concentrations of gefitinib in mice following administration of a single dose of 150 mg/kg intraperitoneally and in cancer patients receiving an oral daily dose of 250 mg.

Animals↗

[Study on characteristics of bias caused by flow injection-capillary electrophoresis with split-flow electrokinetic injection].

The characteristics of bias caused by split-flow electrokinetic injection (SEKI), a new sample injection method applied in coupled flow injection-capillary electrophoretic system (FI-CE), was investigated using pseudoephedrine hydrochloride, a basic drug and ibuprofen, an acidic drug, as model analytes. It was found that bias imposed by SEKI under the conditions of continuous sample matrix/running buffer was similar to that did by electrokinetic injection (EKI). The linearity of calibration curve provided by SEKI was similar to that offered by non-bias hydrodynamic injection (HDI) but significantly better than that obtained by EKI. These features were exploited to improve analytical performances in simultaneous determination of the minor ingredient of pseudoephedrine hydrochloride and the major ingredient of ibuprofen in pharmaceutical preparation. Detectability of 0.7 mg/L for pseudoephedrine hydrochloride, was achieved at a sample throughput rate of 24 times per hour which is 30% lower than that obtained by HDI-based conventional CE. Eleven runs of a test solution containing 13.1 mg/L pseudoephedrine hydrochloride and 81.4 mg/L ibuprofen produced relative standard deviations (RSDs) of 2.8% for the minor ingredient and 1.2% for the major ingredient, which were improved in comparision to that obtained by HDI-based conventional CE. Analytical results for two batches of compound ibuprofen tablets by the SEKI-based FI-CE approach were in good agreement with that obtained by a conventional high performance liquid chromatographic method.

Anti-Inflammatory Agents, Non-Steroidal↗

Chromatographic separation of carotenoids.

The carotenoids are extremely reactive and consequently unstable due to their long system of conjugated double bonds. Several precautions, such as protection against light and oxygen, use of low temperature and antioxidants, analysis in the shortest possible time, should be taken during isolation and chromatography. The food samples, preferably fresh, are homogenized and immediately extracted with a suitable organic solvent. Saponification has been employed in order to hydrolyze the carotenoid esters, remove fatty material and destroy chlorophyll. This optional step facilitates subsequent carotenoid separation, identification and quantification. The separation of carotenoids is usually carried out by column chromatography, thin layer chromatography and high performance liquid chromatography, in analytical or preparative scale, on many stationary phases such as silica-gel, alumina, MgO, Ca(OH)2 and reversed-phase material (C18 and C30). The choice of the most suitable chromatographic method depends on the amount of sample, carotenoid composition, resolution, speed and purity required. Examples of carotenoid separation in different stationary phases will be shown and discussed.

Carotenoids↗

Fluorimetric liquid chromatographic analysis of amantadine in urine and pharmaceutical formulation.

A simple and sensitive liquid chromatographic method is described for the analysis of amantadine and memantine. The method is based on the derivatization of amantadine and memantine extracted from alkalified samples with (2-naphthoxy)acetyl chloride at mild conditions. The resulting derivatives were analyzed by isocratic HPLC with a fluorimetric detector (lambdaex, 227 nm; lambdaem, 348 nm). The linear range for the determination of amantadine or memantine spiked in urine (1.0 ml) was 1.0-10.0 nmol with a detection limit of about 0.2 nmol (S/N = 3; injected sample 20 microl). Only amantadine preparations are available on our local market, and application of the method to the analysis of amantadine in formulation and in the urine of a dosed subject was demonstrated and proved feasible. Quantitation of AT in tablets or capsules is capable in the linear range of 2.0-50.0 microM. Toluene was used as the solvent for extracting amantadine or memantine in samples and the resulting toluene extract was directly subjected to subsequent derivatization without solvent replacement leading to a simpler analytical procedure.

Amantadine↗