Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72Linked to original sources

Setting and stress relaxation behavior of resilient denture liners.

STATEMENT OF PROBLEM: Resilient denture liners are widely used for the patients who are not comfortable with correctly made conventional hard-based dentures because of thin and relatively nonresilient mucosa or severe alveolar resorption. There are several materials used for denture liners and the efficacy in their use is influenced by their viscoelastic properties. PURPOSE: This study evaluated the setting behavior and viscoelastic properties of various types of resilient denture liners and the changes in viscoelasticity with the passage of time. MATERIAL AND METHODS: Four types of resilient denture liners were used. Setting behavior of 5 autopolymerizing materials was evaluated with an oscillating rheometer. Stress relaxation tests were conducted to evaluate the viscoelastic properties of 9 materials and changes that occurred over time by means of Maxwell model analogies. RESULTS: Significant differences were found in the setting behavior of the autopolymerizing materials. The acrylic resin and fluoroethylene materials demonstrated viscoelastic properties and the silicone and polyolephin materials were found to be elastic. The acrylic resin materials exhibited the greatest changes in viscoelastic properties over time when compared with silicone, polyolephin, and fluoroethylene materials. CONCLUSIONS: The results suggest that it is important to select denture liner materials according to clinical situations because of the wide ranges of setting behavior, viscoelastic properties, and durability over time.

Analysis of Variance↗

Reinforcement of acrylic denture base resin by incorporation of various fibers.

This study was designed to evaluate improvements in the mechanical properties of acrylic resin following reinforcement with three types of fiber. Polyester fiber (PE), Kevlar fiber (KF), and glass fiber (GF) were cut into 2, 4, and 6 mm lengths and incorporated at concentrations of 1, 2, and 3% (w/w). The mixtures of resin and fiber were cured at 70 degrees C in a water bath for 13 h, then at 90 degrees C for 1 h, in 70 x 25 x 15 mm stone molds, which were enclosed by dental flasks. The cured resin blocks were cut to an appropriate size and tested for impact strength and bending strength following the methods of ASTM Specification No. 256 and ISO Specification No. 1567, respectively. Specimens used in the impact strength test were reused for the Knoop hardness test. The results showed that the impact strength tended to be enhanced with fiber length and concentration, particularly PE at 3% and 6 mm length, which was significantly stronger than other formulations. Bending strength did not change significantly with the various formulations when compared to a control without fiber. The assessment of Knoop hardness revealed a complex pattern for the various formulations. The Knoop hardness of 3%, 6 mm PE-reinforced resin was comparable to that of the other formulations except for the control without fiber, but for clinical usage this did not adversely affect the merit of acrylic denture base resin. It is concluded that, for improved strength the optimum formulation to reinforce acrylic resin is by incorporation of 3%, 6 mm length PE fibers.

Acrylic Resins↗

Transverse strength and fatigue of denture acrylic-glass fiber composite.

OBJECTIVES: The aims of this experiment were: 1) to test the effect of a high concentration of continuous glass fibers on the transverse strength of test specimens made of heat-cured acrylic resin; and 2) to determine the fatigue weakening of both unreinforced and continuous glass fiber-reinforced specimens of heat-cured acrylic resin shaped into upper complete dentures. METHODS: A three-point loading test was used to determine the transverse strength of test specimens (n = 30 per group). The fatigue test was the constant deflection test (n = 10 per group). RESULTS: The results revealed that, compared to unreinforced specimens, continuous glass fibers at a concentration of 58 wt% enhanced the transverse strength of the test specimens up to 146% (p < 0.001) and increased the fatigue resistance (p < 0.001) during 5 x 10(5) loading cycles. SIGNIFICANCE: This study suggests that by incorporating glass fibers into PMMA denture bases, the strength of the denture can be increased.

Composite Resins↗

Efficacy of ultrasound in removal of intraradicular posts using different techniques.

The efficacy of ultrasound in removing cast metal posts was evaluated in this in vitro study using one or two ultrasound units and ultrasonic vibration for various lengths of time. The crowns of 30 healthy maxillary canines were removed, the roots were embedded in acrylic resin blocks, and the root canals were treated endodontically. The canals were prepared and their impressions were taken with self-curing acrylic resin. After casting with copper-aluminum alloy, the posts were blasted with aluminum oxide and cemented with Panavia F resin cement. The specimens were divided into five groups. In groups I and II, only one ultrasound unit was used for 30 and 60 s, respectively; in groups III and IV, two ultrasound units were used simultaneously for 30 and 60 s, respectively; in group V, ultrasound was not used (control). Ultrasonic vibrations were applied with an Enac OE-5 ultrasound unit and an ST-09 tip. All samples were subjected to traction on an Instron machine (model 4444) at a cross-head speed of 1 mm/min. Analysis of the results revealed a statistically significant difference between the groups (ANOVA, P < 0.01); however the difference between groups II and IV was not statistically significant. The efficacy of ultrasound in removing intraradicular posts was confirmed, and the most effective technique was the use of two ultrasound units, independent of the length of time ultrasound was applied.

Aluminum↗

Denture identification--a simple approach.

In order to find a denture identification method that could be rapidly applied to completed dentures, a variety of spirit pens and commercial and experimental sealants were investigated. The pens were generally rapidly removed by one or more abrasive, denture cleansing, antiseptic or mouthwash agent; the sealants exhibited greater longevity. An experimental sealant (acrylic polymer dissolved in chloroform) was found to be cheap, readily prepared, easily applied, very resistant to abrasion, unaffected by immersion denture cleansers, antiseptics and mouthwashes, to produce no more crazing on dentures than the other sealants investigated, and not to affect the transverse strength of acrylic resin.

Acrylic Resins↗

Quantitative real-time PCR for equine cytokine mRNA in nondecalcified bone tissue embedded in methyl methacrylate.

Specific amplification and quantitation of nucleic acid sequences by the polymerase chain reaction (PCR) has been extensively used for the detection of viral infection and gene expression. Although successful amplification of DNA and RNA sequences extracted from paraffin embedded tissue have been described, there are presently no reports available regarding RNA analysis from bone and calcified tissues embedded in hydrophobic acrylic resin. Here we describe a general method for quantitation of specific mRNA sequences extracted from undecalcified bone sections, fixed in paraformaldehyde, and embedded in a hydrophobic acrylic resin. Total RNA was extracted from defined regions of single 50 microm sawed sections. These RNA preparations are suitable for quantitative PCR analysis of mRNA of different cytokines. In addition, the universally expressed housekeeping GAPDH mRNA proved to be useful as an amplification control and to correct for the degree of RNA degradation, which may vary considerably among samples. Reverse transcribed mRNA was amplified and quantitated in Real-Time PCR using a fluorescein labeled internal TaqMan probe.

Animals↗

Immunomicroscopy: resin techniques and on-section labelling with immunocolloidal gold or immunoperoxidase--planning a protocol.

On-section immunocytochemistry is divided into two parts: (i) processing of biological tissue for section microscopy and (ii) immunolabelling of sections. Many of the more successful microscopical methods employ delicate aldehyde fixation of biological tissue followed by "sympathetic" processing into an acrylic resin. Processing regimens do not have to be complicated. Simple and cost effective room temperature protocols utilising partial dehydration have been devised and they can be as effective as the more complex low temperature techniques in preserving both ultrastructure and antigenic reactivity. The embedded material can be investigated by either light or electron microscopy. Frozen sections can be cut and immunolabelled but only if the tissue is chemically fixed first, as in resin embedding. Fixation with low concentrations of aldehyde will normally better preserve tissue immunoreactivity but this may be at the expense of good ultrastructure with these protocols. If so, low temperature resin embedding methods or rapid freezing and cryosubstitution can be tried. The choice of processing protocol will determine which acrylic resin to use, as will the preference for subsequent immunolabelling with either colloidal gold or peroxidase/diaminobenzidine (DAB). Both types of labelling system offer advantages to localisation studies and can be used in combination for double or even triple labelling. Silver enhancement of the colloidal gold or DAB allows for improved observation by light microscopy.

Animals↗

Seal integrity of hollow-bulb obturators.

Five techniques using various materials were evaluated for their ability to produce a watertight seal between obturator and lid. Leakage was determined by an increase in sample weight above that attributed to sorption and by visualization of water inside the clear acrylic resin samples. A watertight seal was obtained for some samples in each of the test groups. Only the two-flask technique sealed with heat-processed acrylic resin produced a watertight seal in all samples. It was determined that pressure up to 30 psi for 1 hour does not rupture a sealed hollow bulb and immersion under pressure is required to detect leakage of a bulb in a short period of time.

Dental Leakage↗

Provisional restoration for abutment of an existing removable partial denture.

The abutment of an existing removable partial denture may require a crown restoration. Fabrication of a provisional restoration to fit the existing clasp assembly requires special consideration. This article presents a simple technique for fabrication of such provisional restorations. An alginate impression is made of the arch with the removable partial denture in place. The abutment tooth is then prepared, providing adequate clearance between the clasp assembly and the tooth preparation. Cold curing acrylic resin of proper shade is mixed and poured in the impression of the abutment tooth. The impression is then seated in the mouth and removed before the acrylic resin is completely polymerized. The provisional restoration is then separated from the partial denture, finished and polished.

Adult↗

Leaching of tobramycin from PMMA bone cement beads.

The in vitro leaching characteristics of tobramycin from acrylic resin (PMMA) bone cement beads have been determined by a radioimmune assay. Tobramycin was incorporated at two concentrations into bone cement beads fabricated from three commercial brands of acrylic resin. Antibiotic leaching followed a curvilinear relationship of the form X . Y = A . X + B . Y. All beads showed similar tobramycin leaching rates over time but the initial amount of leached material differed with the amount of tobramycin incorporated in the bead and the source of the PMMA bone cement. The data indicate that tobramycin-impregnated PMMA beads permit antibiotic leaching at a controlled rate compatible with possible clinical application.

Bone Cements↗

Occupational skin hazards from synthetic plastics.

Epoxy and acrylic resins have numerous industrial applications but are also widely used in the household environment. These compounds are presently one of the most important sources of occupational contact dermatitis. Contact sensitization to epoxy resins is usually caused by the resin itself but hardeners or other additives, such as reactive diluents, plasticizers, fillers and pigments, can occasionally be responsible. Since completely cured epoxy resins are not sensitizers, epoxy resin sensitization is always due to the presence, in the final polymer, of uncured allergenic low molecular weight oligomers. Acrylates are now considered the fourth most common cause of contact sensitization due to resins. Unpolymerized monomers of acrylic compounds are known to be responsible for the contact allergy. Accelerators, inhibitors and catalysts, which are usually added to the acrylates to promote the polymerization process, can also sensitize. Both allergic and irritant contact dermatitis may be caused by exposure to epoxy or acrylic resins and their additives. Contact urticaria, allergic or irritant airborne contact dermatitis caused by volatile compounds, onychia and paronychia can also occur. From January of 1984 to May of 1992 we detected 39 cases of occupational allergic contact dermatitis to epoxy resin system substances and 11 cases of occupational contact sensitization to acrylic compounds. In our experience, the electronics industry as well as paint and glue related activities were the most important sources of epoxy sensitization. Dental materials and anaerobic sealants were found to be the most frequent acrylate sensitizers.

Acrylic Resins↗

Flexural strength of heat-polymerized polymethyl methacrylate denture resin reinforced with glass, aramid, or nylon fibers.

STATEMENT OF PROBLEM: Despite the favorable properties of conventional PMMA used as a denture base material, its fracture resistance could be improved. PURPOSE: This in vitro study was performed to determine whether the flexural strength of a commercially available, heat-polymerized acrylic denture base material could be improved through reinforcement with 3 types of fibers. MATERIAL AND METHODS: Ten specimens of similar dimensions were prepared for each of the 4 experimental groups: conventional acrylic resin and the same resin reinforced with glass, aramid, or nylon fibers. Flexural strength was evaluated with a 3-point bending test. The results were analyzed with a 1-way analysis of variance. RESULTS: All reinforced specimens showed better flexural strength than the conventional acrylic resin. Specimens reinforced with glass fibers showed the highest flexural strength, followed by aramid and nylon. CONCLUSION: Within the limitations of this study, the flexural strength of heat-polymerized PMMA denture resin was improved after reinforcement with glass or aramid fibers. It may be possible to apply these results to distal extension partial denture bases and provisional fixed partial dentures.

Analysis of Variance↗

Accuracy of second pour casts using dual-arch impressions.

This study compared the accuracy of the second pour of addition silicone impressions made using custom acrylic resin complete-arch trays and two types of dual-arch trays. Thirty impressions were made of a typodont using metal dual-arch, plastic dual-arch and acrylic resin complete-arch custom trays (10 impressions/group). Tooth #30 (first molar) and tooth #32 (third molar) in the typodont were custom metal dies made in the shape of complete crown preparations. On the metal dies were scribed reference marks permitting measurements to be made in the mesial-distal, buccal-lingual and occlusal-gingival dimensions. In addition, an inter-tooth measurement between tooth #30 and #32 was made. Following impression procedures, gypsum casts were poured. The casts were removed from the impression and, 24-hours later, second pours were completed. The distances between reference marks on each cast were measured using a measuring microscope. The measurements from each second pour cast were used to compute a group mean, with values expressed as a percent deviation from the master model. A two way analysis of variance was used to compare the groups. No statistically significant differences were found in accuracy among the three type trays except in the inter-tooth measurement where the metal dual-arch tray was more accurate than the other trays.

Analysis of Variance↗

Component failure in removable partial dentures for patients with severe hypodontia.

Removable partial dentures (RPDs) are frequently used in the treatment of severe hypodontia. The failure rates and modes of failure of 138 such prostheses incorporating acrylic resin onlays were assessed in a retrospective survey. Failures primarily occurred either early or late in the life of the prostheses. Particular problems identified were the low wear resistance of acrylic resin onlays and poor fixation of resin components to metal bases, especially when space was limited.

Anodontia↗

Ceramic flask technique for duplicating a complete denture.

The possibilities for use of the duplicate denture are many. The duplicate denture serves as an excellent custom tray for the final working impression. If it is acceptable on the existing denture, the vertical dimension of the duplicate denture can be directly transferred to the articulator. If not acceptable, the vertical dimension can be altered and checked intraorally by adding or removing acrylic resin on the occlusal surface of the teeth. Alterations in esthetics, phonetics, and occlusion can easily be achieved and tested by replacing the original teeth of the duplicate denture with stock acrylic resin teeth. Alterations to the duplicate denture with subsequent patient approval prior to construction of a new prosthesis eliminates many problems associated with new dentures.

Ceramics↗

Claspless chrome-cobalt transitional removable partial dentures.

Many of the acrylic resin and bent-wire temporary partial dentures in use today produce pathologic changes in the oral mucosa. A method is outlined for the use of chrome-cobalt, instead of acrylic resin, to produce temporary prostheses. The resulting temporary partial dentures are esthetically pleasing and biologically acceptable to the oral tissues.

Chromium Alloys↗

Comparative accuracy of implant impression procedures.

In this study, four impression procedures were assessed for accuracy in a laboratory model that simulated clinical practice. The accuracy of stone casts with brass implant analogs was measured against a standard framework. The fit of the framework on the casts was tested by manual and visual judgment and by microscopic measurement. The measurements supported the clinical judgments. When acrylic resin was used to splint transfer copings in an impression, all casts were acceptable and were more accurate than the best of the two other procedures, which did not use an acrylic resin splint. When an impression material was used to orient the transfer copings, the accuracy was better if undercut copings remained in the impression. When impressions were made by removing an impression from smooth transfer copings and replacing the copings in the impression, the majority of casts were unacceptable.

Analysis of Variance↗