Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Separation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

Separation of fluorescein isothiocyanate-labeled amines by microchip electrophoresis in uncoated and polyvinyl alcohol-coated glass chips using water and dimethyl sulfoxide as solvents of background electrolyte.

On-chip capillary electrophoresis with uncoated and polyvinyl alcohol-coated glass channels in aqueous and nonaqueous dimethyl sulfoxide (DMSO) background electrolyte (BGE) solutions was applied in the separation of five amines derivatized with fluorescein-5-isothiocyanate. In aqueous BGE at pH 9.2, baseline separation of the analytes was not achieved on uncoated glass chips, but the separation was clearly improved when the chip channels were coated with polyvinyl alcohol (PVA). Separation was successful in nonaqueous DMSO electrolyte solution containing ammonium acetate and sodium methoxide, on both uncoated and PVA-coated glass microchips. The differences in the pK(a) values of analytes were probably amplified in DMSO, and all five analytes were at least partly dissociated and were separated. Because the viscosity of DMSO is higher than that of water, the migration times were longer in DMSO.

Amines↗

Effects of partial/asymmetrical filling of micelles and chiral selectors on capillary electrophoresis enantiomeric separation: generation of a gradient.

The effect of several experimental parameters on enantiomeric separations in micellar capillary electrophoresis (MCE) was studied. A model separation system was tested. It was composed of an acidic phosphate buffer with sodium dodecyl sulfate (SDS) and hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as the chiral selector. A substituted angelicin was used as a chiral analyte. Changes in the concentration of SDS micelles/SDS monomers in the presence of HP-beta-CD and their impact on the enantioselective separation were investigated. Variation of the composition of electrolytes in the individual compartments of the separation system (inlet vial, capillary, and outlet vial) affected both the migration times and the resolution of the enantiomers. Current vs. time dependencies also were monitored during the separations. A mathematical model of electromigration in micellar systems with chiral selector present was proposed and a computer simulation was used to explain the observed phenomena and to confirm the generation of a CD/SDS-micelle concentration gradient under certain experimental conditions. This is the reported first attempt of a computer simulation of the complex, dynamic chiral environment of the CD-SDS-MCE system.

2-Hydroxypropyl-beta-cyclodextrin↗

Investigation of the novel mixed-mode stationary phase for capillary electrochromatography. II. Separation of amino acids and peptides on sulfonated naphthalimido-modified silyl silica gel.

The potential of 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP) as a mixed-mode stationary phase for capillary electrochromatography (CEC) was investigated for the separation of charged analytes, taking four amino acids (tyrosine, phenylalanine, tryptophan, histidine) as model analytes. The elution process of these charged analytes in CEC with SNAIP was dominated by a combination of both electrophoretic process and chromatographic process involving hydrophobic as well as electrostatic interactions. In order to study the retention mechanism, the CEC retention factor k* and the velocity factor ke* were measured for the amino acids, which allowed the assessment of the respective contribution from the differential processes underlying the separation. Migration and retention could be mediated by changing various mobile phase compositions, including buffer pH, buffer concentration, and concentration of organic solvent. Based on the results obtained by separation of the amino acids, the separation of eight peptides (Gly-Val, Gly-Phe, Gly-Ile, Gly-His, Gly-Lys, Lys-Lys, Gly-Gly-Gly, Gly-Gly-His) was attempted. A good separation was achieved under an isocratic elution with a mobile phase consisting of 35 mM phosphate buffer (pH 3.8) and 40% methanol.

Amino Acids↗

Proline-coated column for the capillary electrochromatographic separation of amino acids by in-column derivatization.

With 3-trimethoxysilylpropyl chloride as the spacer, a proline-coated capillary column was prepared for the capillary electrochromatographic (CEC) separation of amino acids by in-column derivatization. Nine standard mixtures, including aspartic acid, glutamic acid, valine, phenylalanine, alanine, isoleucine, leucine, tyrosine, and tryptophan, were injected. o-Phthalaldehyde (OPA), OPA/2-mercaptoethanol (2-ME) and OPA/N-acetylcysteine (NAC) in borate buffer were tested as the derivatizing agent. Among them, OPA (50 mM) in borate buffer (pH 9.5, 50 mM) gave the best performance. The formation of isoindole could be detected by UV detection. The sandwich-type injection was carried out in hydrostatic mode (10 cm) with the program R(10 s)S(10 s) R(10 s)W(10 min) with R, S, and W being the reagent, sample, and waiting times. Mesityl oxide, benzyl alcohol, and acetone showed some interaction with the column. A current monitoring method was used instead of the determination of the electroosmotic flow (EOF). The direction of EOF was from anode to cathode even under acidic condition lower than the pI value (6.31) of the bonded group due to some unreacted silanol groups. Some parameters including pH, nature, and concentration of the mobile phase and the effect of organic modifier with regard to the CEC separation were investigated. With the proline-coated column (75 (50) cm x 75 microm ID) the best separation was performed in phosphate buffer (pH 4.00, 100 mM) with an applied voltage of -15 kV. The established method was also compared with those precolumn derivatized prior to the separation with proline-coated column as well as with in-capillary derivatization and separation with a bare fused-silica column.

Amino Acids↗

A screening strategy for the development of enantiomeric separation methods in capillary electrophoresis.

Method development of enantiomeric separations in capillary electrophoresis (CE) is a time-consuming task, since finding the appropriate chiral selector is usually a "trial and error" process. It is impossible to predict the selectivity of a selector towards a certain enantiomer. Therefore, the affinity of all selectors has to be examined one at a time. In order to speed up this process, a strategy is proposed based on simple experimental design methodology. The approach includes first a screening in function of the pH to determine the optimal migration conditions followed by a selection of the right chiral selector by means of Taguchi designs. In the approach several variables, such as the type and concentration of cyclodextrin, the concentration of buffer electrolyte, and the percentage of organic modifier, are varied simultaneously to find initial separation conditions rapidly. The resulting initial separation conditions can be optimized in further steps to be more reproducible. We discuss the results of the approach when applied on a number of selected compounds that are recently in development at Johnson & Johnson--Pharmaceutical Research and Development. Parameters, such as quality of the separation and analysis time, are evaluated to determine initial separation conditions for each compound.

Cyclodextrins↗

Separation of biomolecules using electrophoresis and nanostructures.

A large number of nanostructures have the potential to be used together with electrophoresis as separation media or separation additive in capillary electrophoresis, micellar electrokinetic chromatography, capillary electrochromatography, and other analytical techniques. Among those structures are nanotubes, nanocavities, nanowires, nanoposts, nanocones, nanospheres, molecular imprints, nanoparachutes (conical monodendrons), and general nanoparticles with random structures. This review is focused only on publications describing experimental works using molecular imprints, nanoposts, and nanospheres that are fabricated and applied for the purpose of separation media in electrophoresis-driven separations. The review follows an approximate chronological order in each section. As shown, the most popular are those resulting from molecular imprinting technologies. These biomimetic receptors are used in a great variety of fields, which includes electrophoresis, micellar electrokinetic chromatography, capillary electrochromatography, and other fields not reviewed in this work. A few examples of these other fields are, e.g., liquid chromatography, membranes, extractor or preconcentration techniques, immunosorbent assays, and sensing devices. The second topic scanned in the present work is the nanostructures that are used as obstacles to replace gels or polymers solutions in electrophoresis. Finally, the nascent field of nanospheres of gold and other materials as separation media is also reviewed.

Electrophoresis, Microchip↗

Recent advances in capillary separations for proteomics.

The sequencing of several organisms' genomes, including the human's one, has opened the way for the so-called postgenomic era, which is now routinely coined as "proteomics". The most basic task in proteomics remains the detection and identification of proteins from a biological sample, and the most traditional way to achieve this goal consists of protein separations performed by two-dimensional polyacrylamide gel electrophoresis (2-D PAGE). Still, the 2-D PAGE-mass spectrometry (MS) approach remains lacking in proteome coverage (for proteins having extreme isoelectric points or molecular masses as well as for membrane proteins), dynamic range, sensitivity, and throughput. Consequently, considerable efforts have been devoted to the development of non-gel-based proteome separation technologies in an effort to alleviate the shortcomings in 2-D PAGE while reserving the ability to resolve complex protein and peptide mixtures prior to MS analysis. This review focuses on the most recent advances in capillary-based separation techniques, including capillary liquid chromatography, capillary electrophoresis, and capillary electrokinetic chromatography, and combinations of multiples of these mechanisms, along with the coupling of these techniques to MS. Developments in capillary separations capable of providing extremely high resolving power and selective analyte enrichment are particularly highlighted for their roles within the broader context of a state-of-the-art integrated proteome effort. Miniaturized and integrated multidimensional peptide/protein separations using microfluidics are further summarized for their potential applications in high-throughput protein profiling toward biomarker discovery and clinical diagnosis.

Chromatography, Liquid↗

Microchip separations of protein biotoxins using an integrated hand-held device.

We report the development of a hand-held instrument capable of performing two simultaneous microchip separations (gel and zone electrophoresis), and demonstrate this instrument for the detection of protein biotoxins. Two orthogonal analysis methods are chosen over a single method in order to improve the probability of positive identification of the biotoxin in an unknown mixture. Separations are performed on a single fused-silica wafer containing two separation channels. The chip is housed in a microfluidic manifold that utilizes o-ring sealed fittings to enable facile and reproducible fluidic connection to the chip. Sample is introduced by syringe injection into a septum-sealed port on the device exterior that connects to a sample loop etched onto the chip. Detection of low nanomolar concentrations of fluorescamine-labeled proteins is achieved using a miniaturized laser-induced fluorescence detection module employing two diode lasers, one per separation channel. Independently controlled miniature high-voltage power supplies enable fully programmable electrokinetic sample injection and analysis. As a demonstration of the portability of this instrument, we evaluated its performance in a laboratory field test at the Defence Science and Technology Laboratory with a series of biotoxin variants. The two separation methods cleanly distinguish between members of a biotoxin test set. Analysis of naturally occurring variants of ricin and two closely related staphylococcal enterotoxins indicates the two methods can be used to readily identify ricin in its different forms and can discriminate between two enterotoxin isoforms.

Electrophoresis, Microchip↗

Application of dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium in wall modification for capillary electrophoresis separation of proteins.

A zwitterionic surfactant, dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium (C12H25N+(CH3)2CH2CHOHCH2SO3-), named dodecyl sulfobetaine (DSB), was used as a novel modifier to coat dynamically capillary walls for capillary electrophoresis separation of basic proteins. The DSB coating suppressed the electroosmotic flow (EOF) in the pH range of 3-12. At high DSB concentration, the EOF was suppressed by more than 8.8 times. The DSB coating also prevented successfully the adsorption of cationic proteins on the capillary wall. Anions, such as Cl-, Br-, I-, SO4(2-), CO3(2-), and ClO4-, could be used as running buffer modifiers to adjust the EOF for better separation of analytes. Using this dynamically coated capillary, a mixture of eight inorganic anions achieved complete separation within 4.2 min with the efficiencies from 24,000 to 1,310,000 plates/m. In the presence of ClO4- as EOF adjustor, the separation of a mixture containing four basic proteins (lysozyme, cytochrome c, alpha-chymotrypsinogen A, and myoglobin) yielded efficiencies of 204,000-896,000 plates/m and recoveries of 88%-98%. Migration time reproducibility of these proteins was less than 0.5% relative standard deviation (RSD) from run to run and less than 3.1% RSD from day to day, showing promising application of this novel modifier in protein separation.

Adsorption↗

Microchip electrophoretic protein separation using electroosmotic flow induced by dynamic sodium dodecyl sulfate-coating of uncoated plastic chips.

Separation of sodium dodecyl sulfate (SDS)-protein complexes is difficult on plastic microchips due to protein adsorption onto the wall. In this paper, we elucidated the reasons for the difficulties in separating SDS-protein complexes on plastic microchips, and we then demonstrated an effective method for separating proteins using polymethyl methacrylate (PMMA) microchips. Separation difficulties were found to be dependent on adsorption of SDS onto the hydrophobic surface of the channel, by which cathodic electroosmotic flow (EOF; reversed flow) was generated. Our developed method effectively utilized the reversed flow from this cathodic EOF as a driving force for sample proteins using permanently uncoated but dynamic SDS-coated PMMA microchips. High-speed (6 s) separation of proteins and peptides up to 116 kDa was successfully achieved using this system.

Adsorption↗

Nanoparticle-filled capillary electrophoresis for the separation of long DNA molecules in the presence of hydrodynamic and electrokinetic forces.

We report the analysis of long DNA molecules by nanoparticle-filled capillary electrophoresis (NFCE) under the influences of hydrodynamic and electrokinetic forces. The gold nanoparticle (GNP)/polymer composites (GNPPs) prepared from GNPs and poly(ethylene oxide) were filled in a capillary to act as separation matrices for DNA separation. The separations of lambda-DNA (0.12-23.1 kbp) and high-molecular-weight DNA markers (8.27-48.5 kbp) by NFCE, under an electric field of -140 V/cm and a hydrodynamic flow velocity of 554 microm/s, were accomplished within 5 min. To further investigate the separation mechanism, the migration of lambda-DNA was monitored in real time using a charge-coupled device (CCD) imaging system. The GNPPs provide greater retardation than do conventional polymer media when they are encountered during the electrophoretic process. The presence of interactions between the GNPPs and the DNA molecules is further supported by the fluorescence quenching of prelabeled lambda-DNA, which occurs through an energy transfer mechanism. Based on the results presented in this study, we suggest that the electric field, hydrodynamic flow, and GNPP concentration are the three main determinants of DNA separation in NFCE.

Bacteriophage lambda↗

Screening of mixed poly(ethylene oxide) solutions for microchip separation of double-stranded DNA using an orthogonal design approach.

We describe a quick and systematic optimization of molecular weights (MWs) and concentrations of a series of mixed poly(ethylene oxide) (PEO) matrices for separating specific double-stranded DNA fragments on polymethylmethacrylate-based microchips by using an orthogonal design (ORD) approach. The mixed matrices are composed of PEOs in four MW ranges (M(w) 8 x 10(6), 1 x 10(6), 4 x 10(5), and 1 x 10(5)) with varying concentration ratios. In the mixed solutions, PEO with an intermediate MW of 4 x 10(5) is found to be a dominant factor for separating small DNA fragment pairs (e.g., 82 and 88 bp), while PEO with a high MW of 8 x 10(6) plays an important role in separating intermediate and large fragments (e.g., 271 and 281 bp, 506 and 517 bp, 7 and 10 kbp). High-concentration PEO mixtures give better resolution for short fragments, while dilute PEO mixtures show better resolution for long fragments. The optimized matrices are suitable for high-resolution separation of multiplex polymerase chain reaction-amplified products and restriction digest fragments ranging in size from 20 bp to 40 kbp within 4 min at a constant field strength of 177 V/cm. The experimental results indicate the robustness and speediness of the ORD to screen the contribution of PEO MWs and to tune optimally the PEO concentration ratio of different MWs with reference to the performance of specific DNA fragments separated.

Chromosomes, Human, Y↗

Separation, identification, and interaction of heparin oligosaccharides with granulocyte-colony stimulating factor using capillary electrophoresis and mass spectrometry.

A capillary electrophoresis (CE) method was developed for the separation of heparin oligosaccharides compatible to study the interactions between the oligosaccharides and granulocyte-colony stimulating factor (G-CSF). Unfractionated heparin was eliminitively degraded to heparin oligosaccharides by an endolytic heparinase. The degraded smaller oligosaccharides (M(r) < 1000) were baseline-separated by CE under a 50 mM phosphate buffer (pH 9.0) in 10 min. Standard heparin disaccharides and larger oligosaccharides (1000 < M(r) < 8000) were all separated under optimized separation conditions. Compared with standard heparin disaccharides, smaller oligosaccharides contained one nonsulfated, two monosulfated, and two disulfated disaccharides, but trisulfated disaccharides were not found. The smaller oligosaccharides were also identified and molecular mass was deduced by electrospray ionization-mass spectrometry (ESI-MS). Furthermore, interactions between G-CSF and the oligosaccharides were studied by using capillary zone electrophoresis (CZE) under the above separation conditions. It was found that larger oligosaccharides could interact with G-CSF while smaller oligosaccharides were not observed to bind to G-CSF under the experimental conditions. In conclusion, the purified heparinase could selectively degrade heparin into oligosaccharides and the interaction between G-CSF and heparin was correlated with the chain length of heparin.

Chromatography, Gel↗

A simple microfluidic system for efficient capillary electrophoretic separation and sensitive fluorimetric detection of DNA fragments using light-emitting diode and liquid-core waveguide techniques.

A miniaturized CE system has been developed for fast DNA separations with sensitive fluorimetric detection using a rectangle type light-emitting diode (LED). High sensitivity was achieved by combining liquid-core waveguide (LCW) and lock-in amplification techniques. A Teflon AF-coated silica capillary on a compact 6x3 cm baseplate served as both the separation channel for CE separation and as an LCW for light transmission of fluorescence emission to the detector. An electronically modulated LED illuminated transversely through a 0.2 mm aperture, the detection point on the LCW capillary without focusing, and fluorescence light was transmitted to the capillary outlet. To simplify the optics and enhance collection of light from the capillary outlet, an outlet reservoir was designed, with a light transmission window, positioned directly in front of a photomultiplier tube (PMT), separated only by a high pass filter. Automated sample introduction was achieved using a sequential injection system through a split-flow interface that allowed effective release of gas bubbles. In the separation of a phiX174 HaeIII DNA digest sample, using ethidium bromide as labeling dye, all 11 fragments of the sample were effectively resolved in 400 s, with an S/N ratio comparable to that of a CE system with more sophisticated LIF.

DNA↗

Separation of DNA fragments for fast diagnosis by microchip electrophoresis using programmed field strength gradient.

We evaluated a novel strategy for fast diagnosis by microchip electrophoresis (ME), using programmed field strength gradients (PFSG) in a conventional glass double-T microfluidic chip. The ME-PFSG allows for the ultrafast separation and enhanced resolving power for target DNA fragments. These results are based on electric field strength gradients (FSG) that use an ME separation step in a sieving gel matrix poly-(ethylene oxide). The gradient can develop staircase or programmed shapes FSG over the time. The PFSG method could be easily used to increase separation efficiency and resolution in ME separation of specific size DNA fragments. Compared to ME that uses a conventional and constantly applied electric field (isoelectrostatic) method, the ME-PFSG achieved about 15-fold faster analysis time during the separation of 100 bp DNA ladder. The ME-PFSG was also applied to the fast analysis of the PCR products, 591 and 1191 bp DNA fragments from the 18S rRNA of Babesia gibsoni and Babesia caballi.

Animals↗

Chiral separations on multichannel microfluidic chips.

Chiral separations of FITC-labeled basic drugs on multichannel microfluidic chips with LIF detector were investigated. A preliminary screening procedure for seven neutral CDs was performed under optimized conditions for chiral separations of three FITC-labeled drugs (baclofen, norfenefrine, and tocainide) on a mono-channel microfluidic chip. According to the results of screening, FITC-baclofen and FITC-norfenefrine as well as two chiral selectors including gamma-CD and dimethyl-beta-CD (DM-beta-CD) were selected as models to perform chiral separations on a two-channel chip. FITC-baclofen enantiomers were separated completely by gamma-CD in one channel, while resolution of FITC-norfenefrine enantiomers was achieved by DM-beta-CD in the other channel in the same run. Furthermore, the feasibility of using one chiral selector to separate multiple chiral samples was studied on a four-channel chip. These results show that multichannel chip has a potential for chiral high-throughput screening.

Baclofen↗

Enantiomeric separation of furan derivatives and fused polycycles by cyclodextrin-modified micellar capillary electrophoresis.

The enantiomeric separations of highly hydrophobic furan derivatives and polycycles were performed and optimized using CD-modified micellar CE. The most effective chiral selector for the enantiomeric separation of these analytes was hydroxypropyl-gamma-CD. The effects of CD and SDS concentration and organic modifier were examined in order to optimize the separation conditions. The ratio of CD to surfactant concentration affected the enantiomeric separation significantly, with increases in the derivatized CD concentration generally enhancing resolution. Addition of an organic solvent modifier to the run buffer served to increase the analytes' solubility and enhance the separation efficiency. A highly acidic pH was necessary to effectively suppress the EOF when operating in the reverse polarity mode.

Chromatography, Micellar Electrokinetic Capillary↗

Conformational separation of monosaccharides of glycoproteins labeled with 2-aminoacrydone using microchip electrophoresis.

The conformational separation of monosaccharides labeled with fluorescent 2-aminoacrydone (AMAC) was performed by electrophoresis on a plastic microchip with light-emitting diode confocal fluorescence detection. The AMAC-labeled five neutral monosaccharide mixture (D-glucose (Glc), D-mannose, D-galactose, L-fucose, and D-xylose) or two amino monosaccharide mixture (N-acetyl-D-glucosamine and N-acetyl-D-galactosamine) were well separated at pH 8.5 and 0.5% w/v methylcellulose of 200 mM borate buffer conditions using microchip electrophoresis. The separation was successfully performed considering the difference in stability of the complex between the hydroxyl residue of the monosaccharide and borate ions, and we found that 200 mM and pH 8.5 of borate buffer conditions were critical. High-speed separation for the neutral monosaccharides (50 s) and for amino monosaccharides (70 s) was attained at a 400 V/cm of electric field condition, showing all peak resolutions were greater than 0.9% and RSD of mobility were less than 1.9%. The detection limits of 0.86 microM for Glc and <1 microM for all other monosaccharides were enhanced with the addition of 0.5% w/v methylcellulose to the buffer. These attainments are fully compatible with conventional CE. The analysis of the subtle differences in the conformational stability and the value of the hydroxyl residue of the borate complex allowed the development of an efficient prospective tool for attaining high-resolution separation of monosaccharide mixtures having complicated and analogous conformations.

Aminoacridines↗