Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Refractometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

Fast scanning transmissive delay line for optical coherence tomography.

A novel Fourier domain fast scanning optical delay line is proposed in which the walk-off is eliminated by only two passes through a diffraction grating. Working in transmission, the novel delay line is ideal for balanced optical coherence tomography configurations with recirculation of the reference beam. We evaluate theoretically and experimentally its walk-off and dispersion compensation capabilities.

Equipment Design↗

Spatially resolved Fourier holographic light scattering angular spectroscopy.

We show for what is the first time to our knowledge that digital Fourier holography can be used to record spatially resolved angular light scattering spectra from microscopically structured samples. This is achieved in one or a few digital image captures over large millimeter-scale fields of view. Such spectra are a sensitive measure of microscopic morphology, with wide applications in biological and medical imaging. We demonstrate good agreement between results of experiment and Mie theory for the angular scattering spectra of microspheres in water extracted from local regions within reconstructed 2 x 1 millimeter image sets.

Equipment Design↗

Cell refractive index tomography by digital holographic microscopy.

For what we believe to be the first time, digital holographic microscopy is applied to perform optical diffraction tomography of a pollen grain. Transmission phase images with nanometric axial accuracy are numerically reconstructed from holograms acquired for different orientations of the rotating sample; then the three-dimensional refractive index spatial distribution is computed by inverse radon transform. A precision of 0.01 for the refractive index estimation and a spatial resolution in the micrometer range are demonstrated.

Algorithms↗

Depth from diffracted rotation.

The accuracy of depth estimation based on defocus effects has been essentially limited by the depth of field of the imaging system. We show that depth estimation can be improved significantly relative to classical methods by exploiting three-dimensional diffraction effects. We formulate the problem by using information theory analysis and present, to the best of our knowledge, a new paradigm for depth estimation based on spatially rotating point-spread functions (PSFs). Such PSFs are fundamentally more sensitive to defocus thanks to their first-order axial variation. Our system acquires a frame by using a rotating PSF and jointly processes it with an image acquired by using a standard PSF to recover depth information. Analytical, numerical, and experimental evidence suggest that the approach is suitable for applications such as microscopy and machine vision.

Algorithms↗

Coherence function analysis of the higher-order aberrations of the human eye.

We measured the wavefront aberrations of the eyes of five subjects with a Shack-Hartmann sensor sampling at 21.2 Hz and decomposed the measurements into Zernike aberration terms up to and including the fifth radial order. Coherence function analysis was used to determine the common frequency components between the aberrations within subjects. We found the results to be highly subject dependent. The coherence values were typically <0.4. Possible reasons for this are discussed. Coherence function analysis is a useful tool that can be used in future investigations to determine correlations between the aberration dynamics of the eye and other physiological mechanisms.

Adult↗

Direct determination of the refractive index and thickness of a biolayer based on coupled waveguide-surface plasmon resonance mode.

A coupled waveguide-surface plasmon resonance (CWSPR) biosensor based on the Kretschmann configuration is developed. The CWSPR couples the surface plasmon resonance (SPR) mode and the waveguide mode and generates two sharp resonance dips in the reflectivity spectrum. The proposed biosensor not only retains the same sensing sensitivity as that of a conventional SPR device but also yields sharper dips in the reflectivity spectrum and therefore provides an improved measurement precision. The two reflectivity spectrum dips enable the refractive indices and thicknesses of both the self-assembled monolayer and a layer of human serum albumin absorbed dynamically on the sensing surface to be determined directly on a real-time basis. The CWSPR biosensor provides the capability to detect the biomolecular conformational changes that occur in biomolecular kinetic interactions.

Algorithms↗

Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.

Analog-Digital Conversion↗

Removal of ghost images by using tilted element optical systems with polynomial surfaces for aberration compensation.

A novel solution to problematic ghost images is implemented by using tilted lens elements with polynomial surfaces. Tilting the lens surfaces sends reflections out of the imaging path. The nonrotationally symmetric polynomial surfaces correct aberrations caused by tilts. The complex lens surfaces are fabricated by using gray-scale lithographic patterning of hybrid solgel glass.

Artifacts↗

Incidence-angle dependence of optical reflectivity difference from an ultrathin film on solid surface.

We studied the incidence-angle dependence of the optical reflectivity difference in response to ultrathin films on transparent and opaque substrates. We found that the classical three-layer model reproduces the experimentally obtained angular dependence for a monolayer of xenon on Nb(110) and for a monolayer of protein molecules on functionalized glass. We explore the enhancement of the optical response near the Brewster angle (or its equivalent for opaque substrates) in thin film detection.

Adsorption↗

Imaging and sizing of diamond nanoparticles.

Typical disturbances of biological environment such as background scatter and refractive index variations have little effect on the size-dependent scattering property of highly refractive nanocrystals, which are potentially attractive optical labels. We report on what is to our knowledge the first investigation of these scattering optical labels, and their sizing, in particular, by imaging at subvideo frame rates and analyzing samples of diamond nanocrystals deposited on a glass substrate in air and in a matrix of weakly scattering polymer. The brightness of a diffraction-limited spot appears to serve as a reliable measure of the particle size in the Rayleigh scattering limit.

Algorithms↗

Numerical study of wavelength-swept semiconductor ring lasers: the role of refractive-index nonlinearities in semiconductor optical amplifiers and implications for biomedical imaging applications.

Recent results have demonstrated unprecedented wavelength-tuning speed and repetition rate performance of semiconductor ring lasers incorporating scanning filters. However, several unique operational characteristics of these lasers have not been adequately explained, and the lack of an accurate model has hindered optimization. We numerically investigated the characteristics of these sources, using a semiconductor optical amplifier (SOA) traveling-wave Langevin model, and found good agreement with experimental measurements. In particular, we explored the role of the SOA refractive-index nonlinearities in determining the intracavity frequency-shift-broadening and the emitted power dependence on scan speed and direction. Our model predicts both continuous-wave and pulse operation and shows a universal relationship between the output power of lasers that have different cavity lengths and the filter peak frequency shift per round trip, therefore revealing the advantage of short cavities for high-speed biomedical imaging.

Amplifiers, Electronic↗

Fourier-domain angle-resolved low coherence interferometry through an endoscopic fiber bundle for light-scattering spectroscopy.

We present a novel endoscopic fiber bundle probe incorporated in a Fourier-domain angle-resolved low coherence interferometry system for the measurement of depth-resolved angular scattering distributions to permit the determination of scatterer size via elastic scattering properties. Depth resolution is achieved with a superluminescent diode via a Mach-Zehnder interferometer. The sample is illuminated with a collimated beam, and a Fourier plane image of the backscattered light is collected by a coherent fiber bundle. The angular scattering distribution relayed by the fiber bundle is mixed with the reference field and made to coincide with the input slit of an imaging spectrograph. The data collected are processed in real time, producing a depth-resolved angular scattering distribution in 0.37 s. The data are used to determine the sizes of polystyrene microspheres with subwavelength precision and accuracy.

Endoscopes↗

Diffraction phase microscopy for quantifying cell structure and dynamics.

We have developed diffraction phase microscopy as a new technique for quantitative phase imaging of biological structures. The method combines the principles of common path interferometry and single-shot phase imaging and is characterized by subnanometer path-length stability and millisecond-scale acquisition time. The potential of the technique for quantifying nanoscale motions in live cells is demonstrated by experiments on red blood cells.

Cell Movement↗

Pixel resolution control in numerical reconstruction of digital holography.

A new method for resolution control in numerical reconstruction of digital holography is proposed. The wave field on a tilted or vertical plane can be reconstructed without being subject to the minimum object-to-hologram distance requirement, and the pixel resolution can be easily controlled by adjusting the position of a transitional plane. The proposed method solves the problem of pixel resolution control for small object-to-hologram distances and is especially useful for multicolor, multiwavelength digital holography and metrological applications. Experimental results are presented to verify the idea.

Algorithms↗

Influence of the third-order parameter on diffuse reflectance at small source-detector separations.

Spatially resolved reflectance close to source has received a great deal of attention recently. This research is considered to develop a new noninvasive technique for measuring the optical properties of biological media. Using Monte Carlo simulations, we investigated the influence of third-order parameter 5 on diffuse reflectance and found that the reflectance decreased with an increase of delta at a short source-detector separation of approximately 0.7-2 transport mean free paths. We show that the effects of two parameters, y and second-order parameter delta, on the reflectance are contrary. As a result the influence of the second-order parameter y on the reflectance is irregular when the condition delta delta<<delta gamma is not satisfied.

Algorithms↗

Noninvasive measurement of scattering anisotropy in turbid materials by nonnormal incident illumination.

Many existing methods for the recovery of optical parameters from turbid materials rely on the diffusion approximation, which does not permit the recovery of the degree of anisotropy in the scattering phase function. These methods also make the explicit assumption that light is normally incident at the top surface of the material. We demonstrate a steady-state imaging technique that uses nonnormally incident light to determine anisotropy parameter g by fitting Monte Carlo simulation results to high dynamic range images of the intensity profiles of samples. The proposed method is simpler than existing methods and does not rely on thin samples to produce reasonable results.

Algorithms↗

Extended resolution wide-field optical imaging: objective-launched standing-wave total internal reflection fluorescence microscopy.

Standing-wave total-internal-reflection fluorescence (SW-TIRF) microscopy uses a super-diffraction-limited standing evanescent wave to extract the high-spatial-frequency content of an object through a diffraction-limited optical imaging system. The effective point-spread function is better than a quarter of the emission wavelength. With a 1.45 numerical aperture objective and 532 nm excitation wavelength, a Rayleigh resolution of approximately 100 nm can be achieved, which is better than twice the resolution of conventional TIRF microscopy. This first experimental realization of SW-TIRF in an objective-launched geometry demonstrates the potential for extended resolution imaging at high speed by using wide-field microscopy.

Equipment Design↗