Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RECORDS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

Comparing cardiac action potentials recorded with metal and glass microelectrodes.

Machine-pulled high-impedance glass capillary microelectrode is standard for transmembrane potential (TMP) recordings. However, it is fragile and difficult to impale, especially in beating myocardial tissues. We hypothesize that a high-impedance pure iridium metal electrode can be used as an alternative to the glass microelectrode for TMP recording. The TMPs were simultaneously recorded from isolated perfused swine right ventricles with a metal microelectrode and a standard glass microelectrode during pacing and during ventricular fibrillation. The basic morphology of TMP recorded with these electrodes was comparable. The action potential duration (APD) at 90% repolarization was 241 +/- 29 ms for the metal microelectrode and 236 +/- 31 ms for the glass microelectrode with a good correlation (r = 0.99, P < 0.0001). The maximum slope value of the APD restitution curves during pacing was also significantly correlated. One metal microelectrode and >20 glass microelectrodes were needed per study. We conclude that, in isolated perfused swine right ventricles, the TMP recorded by the metal microelectrode is comparable with that recorded by the glass microelectrode. Because the metal microelectrode is more durable than the glass microelectrode, it can serve as an alternative for APD recording and for restitution analyses.

Action Potentials↗

Massively parallel recording of unit and local field potentials with silicon-based electrodes.

Parallel recording of neuronal activity in the behaving animal is a prerequisite for our understanding of neuronal representation and storage of information. Here we describe the development of micro-machined silicon microelectrode arrays for unit and local field recordings. The two-dimensional probes with 96 or 64 recording sites provided high-density recording of unit and field activity with minimal tissue displacement or damage. The on-chip active circuit eliminated movement and other artifacts and greatly reduced the weight of the headgear. The precise geometry of the recording tips allowed for the estimation of the spatial location of the recorded neurons and for high-resolution estimation of extracellular current source density. Action potentials could be simultaneously recorded from the soma and dendrites of the same neurons. Silicon technology is a promising approach for high-density, high-resolution sampling of neuronal activity in both basic research and prosthetic devices.

Animals↗

A direct comparison of whole cell patch and sharp electrodes by simultaneous recording from single spinal neurons in frog tadpoles.

High-impedance, sharp intracellular electrodes were compared with whole cell patch electrodes by recording from single spinal neurons in immobilized frog tadpoles. A range of neuron properties were examined using sharp or patch test electrodes while making simultaneous recordings with a second control patch electrode. Overall, test patch electrodes did not significantly alter the activity recorded by the control electrode, and recordings from the two electrodes were essentially identical. In contrast, sharp electrode recordings differed from initial control patch recordings. In some cases, differences were due to real changes in neuron properties: the resting membrane potential became less negative and the neuron input resistance (R(i)) fell; this fall was larger for neurons with a higher R(i). In other cases, the control patch electrode revealed that differences were due to the recording properties of the sharp electrode: tip potentials were larger and more variable; resting potentials appeared to be more negative; and spike amplitude was attenuated. However, sharp electrode penetration did not, in most cases, significantly alter the pattern of neuron firing in response to injected current or the normal pattern of activity following sensory stimulation or during fictive swimming. We conclude that sharp electrodes introduce a significant leak to the membrane of tadpole spinal neurons compared with patch electrodes but that this does not change the fundamental firing characteristics or activity of the neurons.

Action Potentials↗

Whole-cell recording of anoxic effects on hippocampal neurons in slices.

1. In 400-microns-thick slices from young adult Sprague-Dawley rats, CA1 pyramidal layer neurons were studied by the whole-cell recording technique. The patch pipettes were filled most often with (in mM) 140 potassium gluconate, 2 MgCl2, and 0.2 guanosine triphosphate (GTP): in many cases, 2 mM ATP and/or 1.1 mM EGTA and 0.1 mM Ca were added. The slices were kept at 30-32 degrees C. 2. Cells recorded with ATP-containing electrodes had a much higher input resistance (RN, 101 +/- 5.6 M omega, mean +/- SE) and somewhat less negative resting potentials (Vm; -59.8 +/- 1.1 mV) than cells recorded with ATP-free electrodes (71 +/- 2.7 M omega and -63.1 +/- 0.8 mV). The presence or absence of ethylene glycol-bis(beta-aminoethyl ether)-N,N,N',N'-tetraacetic acid (EGTA) or the substitution of KCl for potassium gluconate did not significantly affect Vm or RN. 3. Overall changes in Vm and RN elicited by anoxia (95% N2-5% CO2 for 3-6 min) were much less pronounced than those seen previously with intracellular electrodes: instead of a hyperpolarization and a approximately 50% fall in RN, there was only a minor depolarization (by 2.4 +/- 0.7 mV) and a small reduction in RN (by 12 +/- 2.4%). During voltage clamp, at holding potentials approximately -35 mV, anoxia evoked only very small outward currents, especially when we recorded with ATP-containing electrodes. 4. The remaining anoxic changes in RN (but not Vm) were very significantly smaller (P < 0.001) when recorded with ATP-containing electrodes (-6 +/- 1.4%) than with ATP-free electrodes (-19 +/- 2.7%). The presence of internal EGTA (1.1-11 mM) was associated with significantly smaller (P < 0.05) anoxic changes in RN: -9.7 +/- 2.0% versus -17 +/- 3.1% in its absence. EGTA also reduced slow afterhyperpolarizations by 80%, though even 11 mM EGTA did not abolish them. However, EGTA had no significant effect on anoxic changes in Vm and did not suppress voltage sags observed during applications of hyperpolarizing current pulses. 5. Judging by these observations, it appears that 1) the much greater anoxic changes in Vm and RN recorded with intracellular electrodes are probably mediated by a diffusible cytosolic agent and 2) during whole-cell recording, both resting RN and the anoxic fall in RN are more strongly determined by cytosolic [ATP] than [Ca]. How ATP affects RN and anoxic changes in RN remains to be established.

Adenosine Triphosphate↗

Sensorimotor-correlated discharge recorded from ensembles of cerebellar Purkinje cells varies across the estrous cycle of the rat.

1. In the present study, locomotor-correlated activity of cerebellar Purkinje cells, recorded using arrays of microwires chronically implanted in adult female rats, was examined across estrous-cycle-associated fluctuations in endogenous sex steroids. Ongoing studies from this laboratory have shown that systemic and local administration of the sex steroid 17 beta-estradiol (E2) augments excitatory responses of cerebellar Purkinje cells to iontophoretically applied glutamate, recorded in vivo from anesthetized female rats. In addition, this steroid potentiated discharge correlated with limb movement. For the present study, extracellular single-unit activity was recorded from as many as 5-11 Purkinje cells simultaneously during treadmill locomotion paradigms. Motor modulation of activity was recorded across three to five consecutive estrous cycles from behaviorally identified cohorts of neurons to test the hypothesis that fluctuations in endogenous sex steroids alter motor modulation of Purkinje cell discharge. 2. Locomotor-associated discharge correlated with treadmill locomotion was increased by a mean of 47% on proestrus, when E2 levels are elevated, relative to diestrus 1. These changes in discharge rate during treadmill locomotion were of significantly greater magnitude than corresponding cyclic alterations in discharge during stationary periods. 3. Correlations with the circadian cycle were also significant, because peak levels of locomotor-associated discharge on the night of behavioral estrus, following elevations in circulating E2, were on average 67% greater than corresponding discharge recorded during the light (proestrus). 4. Alterations in the step cycle were also observed across the estrous cycle: significant decreases in the duration of the flexion phase (by 265 ms, P < 0.05) were noted on estrus compared with diestrus. 5. When recorded on estrus, Purkinje cell discharge correlated with the stance or flexion phase of the step cycle was greater in magnitude and preceded the event by an average of 130 ms, compared with values determined on diestrus. 6. On estrus, responses of Purkinje neurons to iontophoretically applied quisqualate were enhanced fourfold after administration of exogenous E2, assessed in urethan-anesthetized female rats. 7. In addition, systemic administration of E2 (30 ng iv) potentiated responses of cerebellar Purkinje cells to electrical stimulation of the forepaw by an average of 150%, recorded in anesthetized female rats. 8. These results are consistent with the hypothesis that elevations in circulating E2 are associated with enhanced discharge of cerebellar Purkinje cells in response to pharmacological or electrical stimuli or associated with locomotor behavior.

Animals↗

Intracellular features predicted by extracellular recordings in the hippocampus in vivo.

Multichannel tetrode array recording in awake behaving animals provides a powerful method to record the activity of large numbers of neurons. The power of this method could be extended if further information concerning the intracellular state of the neurons could be extracted from the extracellularly recorded signals. Toward this end, we have simultaneously recorded intracellular and extracellular signals from hippocampal CA1 pyramidal cells and interneurons in the anesthetized rat. We found that several intracellular parameters can be deduced from extracellular spike waveforms. The width of the intracellular action potential is defined precisely by distinct points on the extracellular spike. Amplitude changes of the intracellular action potential are reflected by changes in the amplitude of the initial negative phase of the extracellular spike, and these amplitude changes are dependent on the state of the network. In addition, intracellular recordings from dendrites with simultaneous extracellular recordings from the soma indicate that, on average, action potentials are initiated in the perisomatic region and propagate to the dendrites at 1.68 m/s. Finally we determined that a tetrode in hippocampal area CA1 theoretically should be able to record electrical signals from approximately 1, 000 neurons. Of these, 60-100 neurons should generate spikes of sufficient amplitude to be detectable from the noise and to allow for their separation using current spatial clustering methods. This theoretical maximum is in contrast to the approximately six units that are usually detected per tetrode. From this, we conclude that a large percentage of hippocampal CA1 pyramidal cells are silent in any given behavioral condition.

Action Potentials↗

Epidural recordings of electrical events produced in the spinal cord by segmental, ascending and descending volleys.

Epidural electrodes implanted for a percutaneous trial of therapeutic spinal cord stimulation were used to record electrical events evoked by the stimulation of peripheral nerves or of the spinal cord itself. The data collected in patients with no neurological deficit were analyzed in order (1) to check the consistency between epidural and surface recordings, (2) to get information on the genesis of such potentials, and (3) to demonstrate the feasibility of complex neurophysiological studies by means of epidural electrodes. Spinal cord potentials evoked by segmental volleys were recorded at cervical levels with the recording electrodes anterior, lateral and posterior to the spinal cord. The refractory period of the evoked potentials has been studied as well. Responses to stimulation of the tibial nerve were obtained at T11-12 vertebral level with posterior epidural electrodes. Segmental cervical potentials were characterized by a P10, N11, N13/P13 followed by a slow positivity/negativity. A response of similar waveform, but with different peak latencies, was recorded at segmental levels following tibial nerve stimulation. Such a response showed an increasing number of spikes while ascending along the spinal cord. Maximum conduction velocities in the cord were between 65 and 85 m/s. Our epidural recordings are similar to those obtained from the skin, but with a greater amplitude and waveform resolution. Furthermore, the use of epidural electrodes made it feasible to perform complex examinations of sensory function (i.e., the study of orthodromic and antidromic conduction along the dorsal cord and of the influence of a single dorsal cord volley on the segmental cervical potential). Finally, the genesis of the potentials recorded is discussed.

Adult↗

Methods for recording electrograms of the sinoatrial node during cardiac surgery in man.

Recent reports have shown that it is possible to record extracellular electrograms from the rabbit and dog sinoatrial (SA) node. We applied similar techniques to record SA nodal activity in 23 patients who underwent cardiac surgery for various forms of heart disease. Both a bipolar technique, using pairs of electrodes at various interelectrode distances, and a unipolar technique, using an exploring and an indifferent electrode, were used. To record SA nodal electrograms, polarity was reversed from the conventional electrocardiographic recording; high amplification (100 microV/cm) and low-pass filters (0.15-20 Hz) were used. SA nodal electrograms were recorded from eight of 12 patients using the bipolar method and from nine of 11 patients using the unipolar method. There were no significant differences in the success rate or quality of the recording between the two methods. However, the unipolar method allowed a more accurate localization of the SA node. Human SA nodal electrograms resembled those of the dog and rabbit and showed two distinct slopes: a diastolic slope and an upstroke slope preceding the P wave of the ECG, SA conduction times were 32.4 +/- 2.8 msec (mean +/- SEM) at sinus (PP) cycle lengths of 587.6 +/- 35.6 msec for the bipolar method, and 38.2 +/- 3.2 msec at sinus (PP) cycle lengths of 712.2 +/- 50.7 msec for the unipolar method. These methods for recording of extracellular SA nodal electrograms in man may prove useful in 1) localization of the SA node during open heart surgery and 2) assessment of SA nodal function in health and disease.

Adolescent↗

Electrophysiologic and anatomic basis for fractionated electrograms recorded from healed myocardial infarcts.

The electrophysiologic and anatomic basis for fractionated electrograms were investigated in superfused epicardial preparations from infarcted canine hearts. Fractionated bipolar electrograms were frequently recorded in preparations from infarcts 2 weeks to 18 months old but only rarely in preparations from 5-day-old infarcts. The fractionated electrograms were not caused by movement artifacts. They were not associated with depressed transmembrane resting or action potentials (which were found in the 5-day-old infarcts), but rather transmembrane potentials recorded in the vicinity of the bipolar electrodes were normal. Despite the normal transmembrane potentials, activation time in regions where fractionated electrograms occurred was prolonged. However, prolonged activation time by itself did not cause fractionation, since fractionated electrograms were not recorded from normal preparations in which conduction was markedly slowed by a superfusate containing 16 mM potassium and epinephrine. Unipolar electrograms recorded with glass microelectrodes (tip size 1 to 5 microns) showed that activation in regions where fractionated electrograms were recorded was inhomogeneous. Prepotentials were found preceding the upstrokes of some action potentials in regions where double potentials were recorded, suggesting the possibility of electrotonic transmission across high resistance or inexcitable gaps, but no electrotonic potentials were seen in regions with multicomponent fractionated electrograms. Fractionated electrograms were recorded in regions where infarct healing caused wide separation of individual myocardial fibers while distorting their orientation. The anatomic changes probably caused slow and inhomogeneous activation.

Action Potentials↗

Acoustic recordings from experimental saccular aneurysms in dogs.

In an effort to isolate and characterize the emission of acoustic signals from saccular aneurysms, we made a series of invasive microphone recordings from experimental aneurysms created on the common carotid arteries of dogs using the vein pouch technique. Using a modified probe microphone, we compared recordings from the common carotid artery before creation of the aneurysm to recordings from the aneurysmal surface, both before and after clip occlusion. We then performed spectral analysis, band-pass filtering, and spectrographic analysis to compare the dominant frequency and width of the frequency range of both the aneurysmal and carotid recorded signals. The aneurysmal signals had a significantly higher dominant frequency (p less than or equal to 0.05) and a significantly wider frequency range (p less than or equal to 0.05) than the carotid signals. Aneurysmal signals recorded under conditions of systemic hypotension had a significantly lower frequency (p less than or equal to 0.05) than aneurysmal signals recorded under conditions of hypertension. Our results support the assumptions that acoustic signals from experimental saccular aneurysms are distinct from those of the parent vessel and that the aneurysmal signal can be characterized using passive microphone recordings.

Animals↗

Measuring the effects of supratherapeutic doses of levofloxacin on healthy volunteers using four methods of QT correction and periodic and continuous ECG recordings.

A clinical trial was conducted in healthy volunteers using both periodic and continuous ECG recordings to assess the effect of increasing doses of levofloxacin on the QT and QTc interval. Periodic and continuous ECGs were recorded before and after subjects were dosed with placebo and increasing doses of levofloxacin (500 mg, 1000 mg, 1500 mg) that included doses twice the maximum recommended dose of 750 mg in a double-blind, randomized, four-period, four-sequence crossover trial. Mean heart rate (HR) and the QT and QTc interval after dosing with levofloxacin and placebo were compared, and HR-QT interval relationships defined by linear regression analysis were calculated. After single doses of 1000 and 1500 mg of levofloxacin, HR increased significantly, as measured by periodic and continuous ECG recordings. This transient increase occurred at times of peak plasma concentration and was without symptoms. Mean QT intervals after placebo and mean intervals after levofloxacin were indistinguishable. Using periodic ECG recordings, single doses of 1500 mg were associated with small increases in QTc that were statistically significant. In contrast, an effect on QTc was shown only using the Bazett formula with data obtained from continuous ECG recordings. Together with the finding that levofloxacin does not influence HR-QT relationships, these findings suggest that levofloxacin has little effect on prolonging ventricular repolarization and that small increases in HR associated with high doses of levofloxacin contribute to the drug's apparent effect on QTc. Single doses of 1000 or 1500 mg of levofloxacin transiently increase HR without affecting the uncorrected QT interval. Differences in mean QTc after levofloxacin compared to placebo vary depending on the correction formula used and whether the data analyzed are from periodic or continuous ECG recordings. This work suggests that using continuous ECG recordings in assessing QT/QTc effects of drugs may be of value, particularly with drugs that might influence HR.

Administration, Oral↗

Influence of awareness of the recording of breathing on respiratory pattern in healthy humans.

This study was designed to test whether awareness of the measurement of breathing influences the breathing pattern in healthy subjects under routine laboratory conditions. Seventy four subjects (40 females and 34 males), aged 21-63 yrs, were studied under three different conditions whilst their breathing was being recorded for 5 min by means of inductance plethysmography (Respitrace): 1) subjects were misled into believing that their breathing was not being recorded but that they had to wait for 5 min whilst equipment was calibrated; 2) subjects were instructed that their breathing pattern was being recorded for 5 min; 3) the subject's breathing was recorded for 5 min with mouthpiece and pneumotachograph. The first two conditions were randomized. The Respitrace was calibrated by means of multiple linear regression carried out during the 5 min period of quiet breathing through a mouthpiece. Awareness of the recording of breathing caused prolongation of inspiratory (tI) and expiratory time (tE). Breathing through the mouthpiece resulted in an increase of tI, tE and tidal volume (VT). The breathing irregularities (sighs and end-expiratory pauses) decreased when subjects were aware of the recording of breathing and nearly disappeared when subjects breathed through the mouthpiece. The end-tidal carbon dioxide concentration was not significantly different between the three conditions. Mouthpiece breathing often induced some respiratory discomfort and even anxiety, particularly in females. Awareness by the subject that his or her breathing was being recorded altered the spontaneous breathing pattern, mainly the breathing frequency. In addition, use of a mouthpiece markedly increased tidal volume, particularly in females in whom mouthpiece breathing induced more complaints than in males.

Adult↗

Spatiotemporal receptive field properties of epiretinally recorded spikes and local electroretinograms in cats.

BACKGROUND: Receptive fields of retinal neural signals of different origin can be determined from extracellular microelectrode recordings at the inner retinal surface. However, locations and types of neural processes generating the different signal components are difficult to separate and identify. We here report epiretinal receptive fields (RFs) from simultaneously recorded spikes and local electroretinograms (LERGs) using a semi-chronic multi-electrode in vivo recording technique in cats. Broadband recordings were filtered to yield LERG and multi unit as well as single unit spike signals. RFs were calculated from responses to multifocal pseudo-random spatiotemporal visual stimuli registered at the retinal surface by a 7-electrode array. RESULTS: LERGs exhibit spatially unimodal RFs always centered at the location of the electrode tip. Spike-RFs are either congruent with LERG-RFs (N = 26/61) or shifted distally (N = 35/61) but never proximally with respect to the optic disk. LERG-RFs appear at shorter latencies (11.9 ms +/- 0.5 ms, N = 18) than those of spikes (18.6 ms +/- 0.4 ms, N = 53). Furthermore, OFF-center spike-RFs precede and have shorter response rise times than ON-center spike-RFs. Our results indicate that displaced spike-RFs result from action potentials of ganglion cell axons passing the recording electrode en route to the optic disk while LERG-RFs are related to superimposed postsynaptic potentials of cells near the electrode tip. CONCLUSION: Besides contributing to the understanding of retinal function we demonstrate the caveats that come with recordings from the retinal surface, i.e., the likelihood of recordings from mixed sets of retinal neurons. Implications for the design of an epiretinal visual implant are discussed.

Action Potentials↗

Comparison of depth and subdural electrodes in recording temporal lobe seizures.

Intracranial EEG recording is often required to identify an area of the brain for resective surgery for intractable epilepsy. We simultaneously compared bilaterally placed depth and limited subdural electrode EEG to determine the most effective method of recording seizures from the temporal lobes. Localized complex partial seizures usually appeared earlier in hippocampal depth electrodes and spread later to subdural recording sites. In 3 patients, hippocampal recordings showed localized seizure origin but subdural recording was nonlocalizing due to rapid bilateral seizure propagation. In 1 patient with nonlocalized seizures presumably of extratemporal origin, subdural electrodes incorrectly lateralized seizure origin to a temporal lobe. Auras and subclinical seizures detected by depth electrode recording were often not evident with subdural electrodes. We conclude that EEG recording with hippocampal depth electrodes correctly identifies and lateralizes temporal lobe seizures more often than with limited subdural electrodes.

Adolescent↗

Children's physical activity: using accelerometers to validate a parent proxy record.

INTRODUCTION: The purpose of this study was to validate a parent proxy record of children's physical activity with CSA Model 7164 accelerometers. METHODS: A parent proxy record was developed to record children's activity after school on weekdays and all day long on weekends for 7 d. Parents recorded both duration and intensity of activity (light, medium, hard and very hard). Children simultaneously wore a CSA-7164 accelerometer around their right hip, which served as the objective measurement against which the proxy record was validated. Sixty-five parent/child dyads participated in the study. RESULTS: The overall activity level of the children was low (<3 METs). Spearman-rho analyses indicated that the accelerometer and proxy record showed poor to fair agreement for the entire monitoring period, with parents consistently overreporting their child's activity levels. Correlation between the two instruments was highest at midday on weekends (0.383) and immediately after school on weekdays (0.267). CONCLUSION: Due to the low correlation between this proxy record and the accelerometer, the need still exists for a valid measurement of child physical activity that is both inexpensive and easy to employ in larger community-based interventions.

Child↗

Evaluation of the usefulness of recording the ECG in the 3rd intercostal space and prevalence of Brugada-type ECG in accordance with recently established electrocardiographic criteria.

BACKGROUND: It has been reported that recording electrocardiograms (ECGs) in the 3rd intercostal space (ICS) is one method that can be used for detecting Brugada syndrome; however, the prevalence of Brugada-type ECGs recorded in the 3rd ICS and the usefulness of recording the ECG in the 3rd ICS in accordance with recently established electrocardiographic criteria is unknown. METHODS AND RESULTS: ECGs were recorded in both the 4th and 3rd ICS in 17 Brugada-type ECG patients (group A) and in 206 consecutive male subjects (group B). Brugada-type ECGs were divided into 3 types. In group A, the prevalence of type 1 ECG, which is a coved-type ECG with ST-segment elevation of >/=2 mm, increased from 23.5% to 64.7% when ECG was recorded in the 3rd ICS. The conversion to type 1 ECG was found to be related to induction of ventricular arrhythmia. In group B, the prevalence of Brugada-type ECG increased from 1.5% to 5.8% when the ECG was recorded in the 3rd ICS. CONCLUSIONS: Recording the ECG in the 3rd ICS is useful for identifying high-risk patients with Brugada-type ECG and for detecting concealed Brugada-type ECG.

Adult↗

Multispeed rewritable optical-recording method with an initialization-free phase-change disk.

A new method of multispeed rewritable optical recording is presented. An initialization-free phase-change optical disk is proposed as a candidate for multispeed rewritable optical recording. The simulated results of the initialization-free disk at different linear velocities show that the cooling rate increases from approximately 18.69% to 37.96%. A model that combines the crystallization acceleration effect due to the additional layers and the rapid cooling rate due to the initialization-free disk structure is proposed as the physical mechanism of the multispeed recording method with an initialization-free disk. The dynamic optical-recording properties of the initialization-free DVD-RAM disk at different recording speeds shows that the initialization-free phase-change optical-recording disk is compatible with a broad range of recording speeds from 3.49 to 12.21 m/s.

Journal Article↗

Home sleep monitor for detecting apnea episodes by nasal flow and tracheal sound recordings.

We have developed a portable home sleep monitoring system using nasal airflow (NA), tracheal sound recordings (TSR), and electrocardiogram (ECG). NA was recorded by two thermisters. TSR was recorded by a microphone attached to the skin overlying the cervical trachea. Three kinds of signals were recorded with a cassette recorder. Thirty-seven outpatients who had sleep complaints were monitored during sleep at home using this recorder. Attachment of the pickups was performed by the patients themselves. Recordings were played back and analyzed by a personal computer to evaluate apnea episodes from TSR and R-R intervals beat by beat. This home monitoring system had labor-saving and cost-saving benefits and seemed to be a satisfactory technique for screening.

Ambulatory Care↗