Moderate-power helium plasma as an element-selective detector for gas chromatography of dioxins and other halogenated compounds.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Recently, it has been discovered that carba-closo-dodecaborates can be used as cation exchangers in neutral carrier-based ion-selective chemical sensors. Because of their inherent chemical stability and versatile functionalization chemistries, they offer many advantages that may potentially be exploited for ion analyses that require nontraditional sample conditions, including strongly acidic media. In this work, trimethylammonium salts of undecachlorinated (UCC), undecabrominated (UBC), hexabrominated (HBC), and undecaiodinated (UIC) carborane anions were prepared and evaluated for their potential use in solvent polymeric membrane-based sensors. Computational methods including Natural population analysis and electrostatic mapping were used to predict the ion-exchanging ability of each lipophilic anion. In addition, the sandwich membrane technique was used to evaluate the ion-pairing ability of each carborane anion in situ (i.e., within bis(2-ethylhexyl) sebacate (DOS)- and 2-nitrophenyl octyl ether (o-NPOE)-plasticized ISE membranes). The results of the computational and potentiometric studies found that binding affinity of the anions followed the generalized trend HBC > UCC > UBC > UIC. PVC-DOS bulk optode thin films containing the chromoionophore ETH 5315 and a respective anion were used to determine the chemical stability/lipophilicity of the carboranes and tetrakis[3,5-bis(trifluoromethyl)phenyl] borate (TFPB) in acidic media (0.2 M HOAc) under flowing conditions. The studies found that in terms of stability/lipophilicity UIC > UBC > TFPB approximately UCC >> HBC. Electrodes containing a Pb(2+)-selective ionophore, tert-butylcalix[4]arene-tetrakis(N,N-dimethylthioacetamide)(lead IV), were used to evaluate the functionality of each cation exchanger. An evaluation of response characteristics such as slope and selectivity found that UIC and UBC were quite comparable to the behavior of TFPB. Interestingly, both UIC and UBC showed a marked selectivity improvement over cadmium, with log K(pot)(pb),(Cd) values of -7.19 and -7.29, respectively, with TFPB giving a value of -5.89. Demonstrating excellent stability and suitable electrostatic properties, the carboranes, UIC in particular, are a very promising alternative to the tetraphenylborates and should find widespread application in the field of chemical sensors.
The capabilities of a millisecond pulsed glow discharge time-of-flight mass spectrometer for the quantitative analysis of organic molecules were investigated. Mixtures of analytes were separated by gas chromatography, and mass spectra were collected at three different time regimes during the pulse cycle-the prepeak, plateau, and afterpeak time regimes. Elemental information was collected in the prepeak, structural information in the plateau, and molecular ion information in the afterpeak. A sample mixture containing toluene, o-xylene, o-dichlorobenzene, and a binary mixture of methanol and sec-butanol were considered. Calibration curves were constructed for each time regime based on the intensities of the elemental, fragment, and molecular ions. Optimum linearity (r2 = 0.999) was achieved during the plateau time regime, although calibration in the prepeak was also demonstrated, albeit with slightly poorer correlation coefficients (r2 > 0.959). The minimum limits of detection (MDL) were 392, 422, and 557 ng, for toluene, o-xylene, and o-dichlorobenzene, respectively, using a 3-microL injection and a split ratio of 68:1. For the binary alcohol mixture, MDLs of 1.87 and 2.44 microg were determined for methanol and sec-butanol, respectively, based on the intensity of the 16O+ ion during the prepeak and using a split ratio of 58:1.
We have developed a new interface for a commercial ion trap mass spectrometer equipped with APCI capable of real-time measurements of gaseous compounds with limits of detection on the order of pptv. The new interface has been tested using the detection of Br2 and Cl2 over synthetic seawater ice at atmospheric pressure as a model system. A mechanical pump is used to draw gaseous mixtures through a glass manifold into the corona discharge area, where the molecules are ionized. Analysis of bromine and chlorine in dry air show that ion intensity is affected by the pumping rate and the position of the glass manifold. The mass spectrometer signals for Br2 are linear in the 0.1-10.6 ppbv range, and the estimated 3sigma detection limit is 20 pptv. The MS signals for Cl2 are linear in the 0.2-25 ppbv range, and the estimated 3sigma detection limit is 1 ppbv. This new interface advances the field of analytical chemistry by introducing a practical modification to a commercially available ion trap mass spectrometer that expands the available methods for performing highly specific and sensitive measurements of gases in air at atmospheric pressure.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We report on the identity, characterization, and spatial trends of several brominated flame retardants and hydroxylated (OH-) and methoxylated (MeO-) organohalogen contaminants in bald eagle (Haliaeetus leucocephalus) nestling plasma collected from sites along the west coast of North America. Samples were from four southwestern British Columbia (BC) locations, a reference site in northern BC (Fort St. James; FSJ), and from Santa Catalina Island, CA (SCI), an area of high DDT and PCB contamination. Mean concentrations of sigma polybrominated diphenyl ether (sigma PBDE (8 congeners monitored); 1.78-8.49 ng/g), sigma OH-polychlorinated biphenyl (sigma OH-PCB (30 congeners monitored); 0.44-0.87 ng/g), and sigma OH-PBDE (14 congeners monitored; 0.31-0.92 ng/g) were similar in eaglets from southwestern BC yet lower than for SCl and significantly higher than for FSJ. Dominant PBDE congeners were BDE47, BDE99, and BDE100, but SCl eaglets also contained low levels of higher brominated congeners. 4-OH-CB187 and 4'-OH-CB202 accounted for 65-100% of sigma OH-PCB in all BC eaglets, with 4'-OH-CB202 as well as 3'-OH-CB138 and 4-OH-CB146 dominating in SCl eaglets. Ostensibly of biogenic origin, 6'-OH-BDE49 and 6-OH-BDE47 were found in BC nestlings. Only 4'-OH-BDE49 (2.10 ng/g) was found in SCl eaglets. MeO-PBDEs and total hexabromocyclododecane (HBCD) were not found in any birds, but the polybrominated biphenyl BB101 was detected in southwestern BC samples. This study demonstrates that west coast North American bald eagles contain previously unreported organohalogens, which have the potential to impact the health and survival of these raptors.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A mild and general method for the conversion of aryl, heteroaryl, and vinyl bromides into the corresponding iodides was developed utilizing a catalyst system comprising 5 mol % of CuI and 10 mol % of a 1,2- or 1,3-diamine ligand. A variety of polar functional groups are tolerated, and even N-H containing substrates such as sulfonamides, amides, and indoles are compatible with the reaction conditions. Both the reaction rate and the equilibrium conversion of the aryl bromide depend on the choice of the halide salt and the solvent. The best results were obtained using NaI as the halide salt and dioxane, n-butanol, or n-pentanol as the solvents.
Explore the source record for details and available documents.
The first report of the biological production of bromo ochratoxin B by Aspergillus ochraceus Wilh. is presented as well as a study of the influence of potassium bromide, potassium iodide, potassium fluoride, and potassium chloride on the production of ochratoxin A and ochratoxin B. Potassium fluoride and potassium iodide inhibited the growth of the fungus, whereas potassium chloride substantially stimulated the production of ochratoxin A in shaken solid substrate fermentation on whole wheat or shredded wheat, generally giving a high yield of ochratoxins. Increasing levels of potassium bromide led to a decline in ochratoxin A production and an increase in bromo-ochratoxin B, ochratoxin B, and 4-hydroxy ochratoxin B. Nevertheless, A. ochraceus was much less versatile in the bromo analogues than other fungi, which produce metabolites containing chlorine. Analysis included aminopropyl solid-phase extraction column cleanup followed by quantitative analysis on reversed-phase HPLC using fluorescence detection and employing N-(5-chloro-2-hydroxybenzoyl)phenylalanine as an internal standard.
Explore the source record for details and available documents.
Explore the source record for details and available documents.