Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

Integrated lectin affinity microfluidic chip for glycoform separation.

Lectin affinity chromatography was miniaturized into a microfluidic format, which results in improvement of performance, as compared to the conventional method. A lectin affinity monolith column was prepared in the microchannel of a microfluidic chip. The porous monolith was fabricated by UV-initiated polymerization of ethylene dimethacrylate (EDMA) and glycidyl methacrylate (GMA) in the presence of porogeneities, followed by immobilization of pisum sativum agglutinin (PSA) on the monolith matrix. Using electroosmosis as the driven force, lectin affinity chromatographies of three kinds of glycoprotein, turkey ovalbumin (TO), chicken ovalbumin (CO), and ovomucoid (OM), were carried out on the microfluidic system. All the glycoproteins were successfully separated into several fractions with different affinities toward the immobilized PSA. The integrated system reduces the time required for the lectin affinity chromatography reaction to approximately 3%, thus, the overall analysis time from 4 h to 400 s. Only 300 pg of glycoprotein is required for the whole separation process. Moreover, troublesome operations for lectin affinity chromatography are simplified.

Adsorption↗

On-chip high-pressure picoliter injector for pressure-driven flow through porous media.

A high-pressure (> 3 MPa) on-chip injector has been developed for microchip applications including HPLC. The mechanical injector is implemented using in situ photopolymerization of fluorinated acrylates inside wet-etched silica microchips. The injector allows reproducible injections as small as 180 pL with < 250 ms duration. The injector operated robustly over 60 days and over 1000 injections. The injector is unique among polymer-based valves as it functions in aqueous, acetonitrile, and mixed buffers at high pressures without detectable leakage.

Acrylates↗

Multistage isoelectric focusing in a polymeric microfluidic chip.

This paper reports a protocol that improves the resolving power of isoelectric focusing (IEF) in a polymeric microfluidic chip. This method couples several stages of IEF in series by first focusing proteins in a straight channel using broad-range ampholytes and then refocusing segments of the first channel into secondary channels that branch from the first one at T-junctions. Experiments demonstrate that several fluorescent proteins that had focused within a segment of the straight channel in the first stage were refocused at significantly higher resolution due to the shallower pH gradient and higher electrical field gradient. Two variants of green fluorescent protein from the second-stage IEF fractionation were further separated in a third stage. Three stages of IEF were completed in less than 25 min at electric field strengths ranging from 50 to 214 V/cm.

Dimethylpolysiloxanes↗

On-chip millionfold sample stacking using transient isotachophoresis.

We present a simple and robust isotachophoresis (ITP) method that can be integrated with microchip-based capillary electrophoresis (CE) devices to achieve millionfold sample stacking. We performed an experimental parametric study to show the effects of initial sample ion concentration, leading ion concentration, and trailing ion concentration on ITP stacking. We also discuss the usefulness and limitations of a simple one-dimensional nondispersive model and a scaling analysis for dispersion rate. We found that a single-column ITP configuration together with electroosmotic flow suppression and high leading ion concentration provide high-performance ITP and can be integrated readily with CE separation. We demonstrated detection of trace of 100 fM Alexa Fluor 488 (signal-to-noise ratio of 11) with a concentration increase of a factor of 2 x 10(6). Application of our ITP/CE protocol to the stacking and separation of negatively charged fluorescent tracers (Alexa Fluor 488 and bodipy) resulted in a concentration increase of 6.4 x 10(4) and a signal increase of 4.5 x 10(5). The ITP/CE protocol can be performed with a standard microchannel cross design or simple flow control. The method can be implemented with available off-the-shelf chip systems using off-the-shelf voltage control systems and buffer chemistries.

Journal Article↗

Hybrid dynamic coating with n-dodecyl beta-D-maltoside and methyl cellulose for high-performance carbohydrate analysis on poly(methyl methacrylate) chips.

Hybrid dynamic coating using n-dodecyl beta-d-maltoside (DDM) and methyl cellulose (MC) has been developed for suppression of analyte adsorption and electroosmotic flow (EOF) in a poly(methyl methacrylate) (PMMA) channel. The adsorption of APTS-labeled sugars in a PMMA channel was obviously suppressed with DDM dynamic coating; however, EOF was reduced only by a factor of approximately 25%, resulting in irreproducible separations. In contrast, both analyte adsorption and EOF in a PMMA channel were efficiently minimized with MC coating; however, concentrated MC above 0.3% was required to achieve high-performance separations, which greatly increased viscosity of the solution and caused difficulties during buffer loading and rinsing. In addition, n-dodecyltrimethylammonium chloride did not show observable effects on reducing analyte adsorption, although it has the same hydrophobic alkyl chain as DDM. These results strongly indicated that the polysaccharide moiety of surface modifiers has a specific affinity to surface charges and is crucial to achieving efficient and stable dynamic coating on the PMMA surface. Hybrid dynamic coating with 0.25% DDM and 0.03% MC was found to minimize both analyte adsorption and EOF in a PMMA channel to a negligible level, while still keeping a low viscosity of the solution. High-speed and high-throughput profiling of the N-linked glycans derived from alpha1-acid glycoprotein, fetuin, and ribonuclease B was demonstrated in both single-channel and 10-channel PMMA chips using DDM-MC hybrid coating. We propose that DDM-MC hybrid coating might be a general method for suppressing analyte adsorption and EOF in polymer MCE devices. The current MCE-based method might be a promising alternative for high-throughput screening of carbohydrate alterations in glycoproteins.

Adsorption↗

Phase-changing sacrificial materials for interfacing microfluidics with ion-permeable membranes to create on-chip preconcentrators and electric field gradient focusing microchips.

We have developed a novel approach for interfacing ionically conductive membranes with microfluidic systems using phase-changing sacrificial layers. Imprinted microchannels in a polymer substrate are filled with a heated liquid that solidifies at room temperature, a monomer solution is placed over the protected channels and polymerized to form a rigid semipermeable copolymer, and then the protective layer is melted and removed, leaving an open microchannel interfaced with a polymer membrane. We have applied this method in miniaturizing electric field gradient focusing (EFGF) and carrying out on-chip protein preconcentration. A semipermeable copolymer in the EFGF microchips fills a region of changing cross-sectional area, which allows a gradient in electric field to be established when an electrical potential is applied. Our technique provides microchip EFGF devices that offer 3-fold improved resolution in protein focusing compared with capillary-based systems. In addition, these EFGF microchips can separate peptide samples with resolution similar to what is obtained in capillary electrophoresis microdevices, and the micro-EFGF systems enrich analytes by a factor of >150. Finally, we have fabricated membrane-integrated microfluidic devices that can concentrate protein samples (R-phycoerythrin) over 10 000-fold to facilitate microchip capillary electrophoresis. Interfacing microchannels with ion-permeable membranes has great potential to enhance microchip analysis of biomolecules.

Electric Conductivity↗

Continuous-flow pI-based sorting of proteins and peptides in a microfluidic chip using diffusion potential.

Efficient sample preparation tools are the key to measuring molecular signals in a complex biological system. A novel continuous-flow isoelectric point (pI)-based sorting technique has been developed for proteins and peptides in a microfluidic chip format. It can sort biomolecules at a relatively high flow rate of up to 10 microL/min and does not require carrier ampholytes, which can create molecular backgrounds for subsequent analysis. Furthermore, the electrophoretic field required to run the pI-based sorting is generated by the diffusion of buffer ions in situ, at the liquid junction between two laminar flows within the microfluidic channel. Utilizing the diffusion potential in combination with a pH difference between the buffers, we demonstrated a separation of binary mixtures of pI markers and proteins without applying any external field. The sorting resolution and its efficiency are sufficiently high for sample preparation and could be further improved by optimizing buffers or with an additional transverse electric field. Once fully developed, it can potentially be a pI-based sample fractionation tool for proteomic analysis of complex biomolecule samples.

Diffusion↗

Electrokinetic protein preconcentration using a simple glass/poly(dimethylsiloxane) microfluidic chip.

We discovered that a protein concentration device can be constructed using a simple one-layer fabrication process. Microfluidic half-channels are molded using standard procedures in PDMS; the PDMS layer is reversibly bonded to a glass base such as a microscope slide. The microfluidic channels are chevron-shaped, in mirror image orientation, with their apexes designed to pass within approximately 20 microm of each other, forming a thin-walled section between the channels. When an electric field is applied across this thin-walled section, negatively charged proteins are observed to concentrate on the anode side of it. About 10(3)-10(6)-fold protein concentration was achieved in 30 min. Subsequent separation of two different concentrated proteins is easily achieved by switching the direction of the electric field in the direction parallel to the thin-walled section. We hypothesize that a nanoscale channel forms between the PDMS and the glass due to the weak, reversible bonding method. This hypothesis is supported by the observation that, when the PDMS and glass are irreversibly bonded, this phenomenon is not observed until a very high E-field was applied and dielectric breakdown of the PDMS is observed. We therefore suspect that the ion exclusion-enrichment effect caused by electrical double layer overlapping induces cationic selectivity of this nanochannel. This simple on-chip protein preconcentration and separation device could be a useful component in practically any PDMS-on-glass microfluidic device used for protein assays.

Animals↗

On-chip titration of an anticoagulant argatroban and determination of the clotting time within whole blood or plasma using a plug-based microfluidic system.

This paper describes extending plug-based microfluidics to handling complex biological fluids such as blood, solving the problem of injecting additional reagents into plugs, and applying this system to measuring of clotting time in small volumes of whole blood and plasma. Plugs are droplets transported through microchannels by fluorocarbon fluids. A plug-based microfluidic system was developed to titrate an anticoagulant (argatroban) into blood samples and to measure the clotting time using the activated partial thromboplastin time (APTT) test. To carry out these experiments, the following techniques were developed for a plug-based system: (i) using Teflon AF coating on the microchannel wall to enable formation of plugs containing blood and transport of the solid fibrin clots within plugs, (ii) using a hydrophilic glass capillary to enable reliable merging of a reagent from an aqueous stream into plugs, (iii) using bright-field microscopy to detect the formation of a fibrin clot within plugs and using fluorescent microscopy to detect the production of thrombin using a fluorogenic substrate, and (iv) titration of argatroban (0-1.5 microg/mL) into plugs and measurement of the resulting APTTs at room temperature (23 degrees C) and physiological temperature (37 degrees C). APTT measurements were conducted with normal pooled plasma (platelet-poor plasma) and with donor's blood samples (both whole blood and platelet-rich plasma). APTT values and APTT ratios measured by the plug-based microfluidic device were compared to the results from a clinical laboratory at 37 degrees C. APTT obtained from the on-chip assay were about double those from the clinical laboratory but the APTT ratios from these two methods agreed well with each other.

Anticoagulants↗

Capillary electrophoresis chips with integrated electrochemical detection.

Capillary electrophoresis systems with integrated electrochemical detection have been microfabricated on glass substrates. Photolithographic placement of the working electrode just outside the exit of the electrophoresis channel provides high-sensitivity electrochemical detection with minimal interference from the separation electric field. Microchip electrophoretic separations of neurotransmitters in under 100 s exemplify the good resolution and attomole detection sensitivity of these devices. Using indirect electrochemical detection, high-sensitivity DNA restriction fragment and PCR product sizing has also been performed. These microdevices match the detector's size to that of microfabricated separation and reaction devices, bringing to reality the lab-on-a-chip concept.

DNA↗

Adaptation of capillary isoelectric focusing to microchannels on a glass chip.

As a first step toward adaptation of capillary isoelectric focusing (cIEF) to microchannels on a glass chip, we have compared the three most common mobilization methods: chemical, hydrodynamic, and electroosmotic flow (EOF)-driven mobilization. Using a commercial cIEF apparatus with coated or uncoated fused-silica capillaries, both chemical and hydrodynamic mobilization gave superior separation efficiency and reproducibility. However, EOF-driven mobilization, which occurs simultaneously with focusing, proved most suitable for miniaturization because of high speed, EOF compatibility and low instrumentation requirements. When this method was tested in a 200-micron-wide, 10-micron-deep, and 7-cm-long channel etched into planar glass, a mixture of Cy5-labeled peptides could be focused in less than 30 s, with plate heights of 0.4 micron (410 plates/s) upon optimization. For a total analysis time of less than 5 min, we estimate a maximum peak capacity of approximately 30-40. Interestingly, the order of migration was found to be reversed compared to capillary-based focusing.

Glass↗

Dynamic DNA hybridization on a chip using paramagnetic beads.

Dynamic DNA hybridization is presented as an approach to perform gene expression analysis. The method is advantageous because of its dynamic supplies of both DNA samples and probes. The approach was demonstrated on a microfluidic platform by incorporating paramagnetic beads as a transportable solid support. A glass chip was fabricated to allow simultaneous interrogation of eight DNA target samples by DNA probes. DNA targets were immobilized on beads via streptavidin-biotin conjugation or base pairing between oligonucleotide residues. The DNA/bead complex was introduced into the device in which hybridization took place with a complementary probe. The hybridized probe was then removed by heat denaturation to allow the DNA sample to be interrogated again by another probe with a different sequence of interest. A pneumatic pumping apparatus was constructed to transport DNA probes and other reagents into the microfluidic device while hydrostatic pumping was used for the introduction of paramagnetic beads with samples. After investigating three types of paramagnetic beads, we found Dynabeads Oligo(dT)25 best suited this application. Targets on the beads could be sequentially interrogated by probes for 12 times, and the hybridization signal was maintained within experimental variation. Demonstration of specific hybridization reactions in an array format was achieved using four synthesized DNA targets in duplicate and five probes in sequence, indicating the potential application of this approach to gene expression analysis.

Actins↗

Single-molecule detection of DNA separations in microfabricated capillary electrophoresis chips employing focused molecular streams.

DNA separations have been performed using microfabricated capillary electrophoresis chips and detected using a single-molecule fluorescence burst counting technique. We enhanced the percentage of electromigrating DNA molecules that were detected by focusing the sample through the 1-microm-diameter focused laser beam. The sample was focused by introducing a taper in the separation channel and by a sheath flow delivered from cross channels. The sample stream width, single-molecule velocities, and single-molecule count rates varied linearly with the current density ratio as expected. The optimal laser power for each focusing condition was investigated using dilute solutions of pBluescript DNA. Although fluorescence burst heights and background varied with laser power, the signal-to-noise ratio was only weakly dependent on this parameter using our single-molecule counting technique. Focused single-molecule counting was used to detect separations of a 100-1000-bp DNA sizing ladder. The increase in molecular detection efficiency was quantified by applying a focusing current midway through the ladder separation and comparing observed count rates to the known molecular concentration in the bands. The molecular detection efficiency varied linearly with the applied current density ratio, and greater than 3-fold enhancements in detection efficiency were achieved.

DNA↗

Integration of a microextraction system on a glass chip: ion-pair solvent extraction of Fe(II) with 4,7-diphenyl-1,10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride

An ion-pair solvent extraction was performed in a microchannel fabricated in a quartz glass chip. the aqueous solution of Fe-bathophenanthrolinedisulfonic acid complex and the chloroform solution of tri-n-octylmethylammonium chloride were introduced into the microchannel, and a parallel two-phase laminar flow was formed. The ion-pair product extracted in chloroform was monitored by the thermal lens microscope. The ion-pair product was gradually extracted from aqueous solution into chloroform when the flow was very slow or stopped, while nothing was extracted into chloroform when the flow was fast. The time for extraction in the present 250 microns microchannel, 45 s, roughly coincided with the molecular diffusion time, and the extraction time was at least 1 order shorter compared with the ordinary extraction time using a separatory funnel and mechanical shaking. The microspace in the microchannel was characterized by the large specific interface area and short diffusion distance, and these characteristics may contribute to highly efficient extraction without mechanical shaking. The success of this molecular transport may lead to the integration of more complicated separation and chemical operations on a microchip and more applications.

Journal Article↗

Reversible surface thiol immobilization of carboxyl group containing haptens to a BIAcore biosensor chip enabling repeated usage of a single sensor surface.

We describe a reversible immobilization method for carboxyl group containing haptens that makes the repeated usage of a BIAcore biosensor chip possible. Haptens which are immobilized according to the surface thiol method can be removed completely from the sensor surface again by a reducing step. In the first part of our study, analogues of the herbicides 2,4-dichlorophenoxyacetic acid and 2,4,5-trichlorophenoxyacetic acid were immobilized in succession to a biosensor surface of a BIAcore surface plasmon resonance instrument according to the thiol coupling method. Direct kinetic analysis of these ligands to a polyclonal anti-2,4-dichlorophenoxyacetic acid antibody were performed using these biosensor surfaces. In the second part of the study, different amounts of 2,4-dichlorophenoxyacetic acid were sequentially immobilized onto the same biosensor surface in order to generate a calibration plot for 2,4-dichlorophenoxyacetic acid. Using this plot, the quantitative detection of the herbicide down to a concentration of 0.1 microg/mL, the maximum admissible concentration of pesticides in drinking water, is possible.

2,4,5-Trichlorophenoxyacetic Acid↗

Aryldiazomethanes for universal labeling of nucleic acids and analysis on DNA chips.

DNA and RNA labeling and detection are key steps in nucleic acid-based technologies, used in medical research and molecular diagnostics. We report here the synthesis, reactivity, and potential of a new type of labeling molecule, m-(N-Biotinoylamino)phenylmethyldiazomethane (m-BioPMDAM), that reacts selectively and efficiently with phosphates in nucleotide monomers, oligonucleotides, DNA, and RNA. This molecule contains a biotin as detectable unit and a diazomethyl function as reactive moiety. We demonstrate that this label fulfills the requirements of stability, solubility, reactivity, and selectivity for hybridization-based analysis and especially for detection on high-density DNA chips.

Biotinylation↗

Immobilization and clustering of structurally defined oligosaccharides for sugar chips: an improved method for surface plasmon resonance analysis of protein-carbohydrate interactions.

Oligosaccharides are increasingly being recognized as important partners in receptor-ligand binding and cellular signaling. Surface plasmon resonance (SPR) is a very powerful tool for the real-time study of the specific interactions between biological molecules. We report here an advanced method for the immobilization of oligosaccharides in clustered structures for SPR and their application to the analysis of heparin-protein interactions. Reductive amination reactions and linker molecules were designed and optimized. Using mono-, tri-, or tetravalent linker compounds, we incorporated synthetic structurally defined disaccharide units of heparin and immobilized them as ligands for SPR. Their binding to an important hemostatic protein, von Willebrand factor (vWf), and its known heparin-binding domain was quantitatively analyzed. These multivalent ligand conjugates exhibited reproducible binding behavior, with consistency of the surface conditions of the SPR chip. This novel technique for oligosaccharide immobilization in SPR studies is accurate, specific, and easily applicable to both synthetic and naturally derived oligosaccharides.

Animals↗

Microfabricated polymer chip for capillary gel electrophoresis.

A polymer (PDMS: poly(dimethylsiloxane)) microchip for capillary gel electrophoresis that can separate different sizes of DNA molecules in a small experimental scale is presented. This microchip can be easily produced by a simple PDMS molding method against a microfabricated master without the use of elaborate bonding processes. This PDMS microchip could be used as a single use device unlike conventional microchips made of glass, quartz or silicon. The capillary channel on the chip was partially filled with agarose gel that can enhance separation resolution of different sizes of DNA molecules and can shorten the channel length required for the separation of the sample compared to capillary electrophoresis in free-flow or polymer solution format. We discuss the optimal conditions for the gel preparation that could be used in the microchannel. DNA molecules were successfully driven by an electric field and separated to form bands in the range of 100 bp to 1 kbp in a 2.0% agarose-filled microchannel with 8 mm of effective separation length.

Coated Materials, Biocompatible↗