Affinity chromatography: a review of clinical applications.

Affinity chromatography is a type of liquid chromatography that makes use of biological-like interactions for the separation and specific analysis of sample components. This review describes the basic principles of affinity chromatography and examines its use in the testing of clinical samples, with an emphasis on HPLC-based methods. Some traditional applications of this approach include the use of boronate, lectin, protein A or protein G, and immunoaffinity supports for the direct quantification of solutes. Newer techniques that use antibody-based columns for on- or off-line sample extraction are examined in detail, as are methods that use affinity chromatography in combination with other analytical methods, such as reversed-phase liquid chromatography, gas chromatography, and capillary electrophoresis. Indirect analyte detection methods are also described in which immunoaffinity chromatography is used to perform flow-based immunoassays. Other applications that are reviewed include affinity-based chiral separations and the use of affinity chromatography for the study of drug or hormone interactions with binding proteins. Some areas of possible future developments are then considered, such as tandem affinity methods and the use of synthetic dyes, immobilized metal ions, molecular imprints, or aptamers as affinity ligands for clinical analytes.

Chemistry, Clinical↗

[Applications and progresses of expert system on chromatography].

The expert system on chromatography has achieved great advancement in the past two decades, and is playing a more and more important role in solving analytical problems of complex samples. Research results of expert system on chromatography in authors' group are reviewed with 64 references. A brief introduction of the expert system on chromatography is presented. Applications of the expert system on chromatography are summarized in the fields of petrochemical online analysis, environmental air sample analysis, tumor diagnosis and traditional Chinese medicine analysis. The review followed the scientific foot steps in the authors' group, starting from the development of the expert system on gas chromatography, to the selection of multi-column systems in online industrial gas chromatographs in petrochemical plants, and to the employment of the new techniques in gas chromatography, liquid chromatography and capillary electrophoresis to solve the practical analytical problems in the nation's scientific and economic development.

Chromatography↗

Stationary phase-based two-dimensional chromatography combining both covalent and noncovalent interactions on a single HPLC column.

A new type of 2-D separation material was synthesized and studied. The material is suitable for 2-D chromatography utilizing both covalent and noncovalent interactions. The first dimension is boronate affinity chromatography, and the second dimension is RP chromatography (or vice versa). The polymeric media were prepared using p-vinylphenylboronic acid as the functional monomer. This monomer was selected due to the presence of the boronic acid group for the cis-diol/boronate interaction in boronate chromatography. Two crosslinkers were evaluated, namely ethylene glycol dimethacrylate and divinylbenzene. The crosslinker content was varied to maximize the polymer strength and the RP performance of the packed column. Several parameters were evaluated to define the optimum for polymer strength and column performance including crosslinker, porogen, initiator, and column-packing parameters. The polymer-based HPLC columns were successful in separating phenol, catechol, dimethylphthalate, and hydroquinone under RP conditions, and thus can be used as an RP HPLC column. The columns were also successful in separating catechol and adenosine under boronate chromatography conditions, and thus can be used as a boronate affinity column. Moreover, the two types of chromatography can be performed consecutively on the same column during one complete chromatographic run, making it a 2-D chromatography. Under these 2-D conditions, the catechol was separated from a mixture of phenol, catechol, dimethylphthalate, and hydroquinone; the adenosine ribonucleoside was separated from a mixture of adenosine ribonucleoside, adenosine deoxyribonucleoside, and uridine deoxyribonucleoside. This type of single-column 2-D HPLC eliminates the requirement of a complex and expensive multidimensional HPLC instrument and provides increased peak capacity for separation.

Boronic Acids↗

Csaba Horváth and preparative liquid chromatography.

Few chromatographers have been interested in furthering preparative liquid chromatography. The pioneers, Tswett, Kuhn and Lederer, A.J.P. Martin, Tiselius, isolated fractions but as an intermediate step in the analysis of their samples. The progress in electronics and sensors, and in their miniaturization has lead to the paradoxical situation that the analysts never see the transient pure fractions that their detector quantitates. Yet, over the last 25 years, preparative liquid chromatography has become an important industrial process for the separation, the extraction, and/or the purification of many pharmaceuticals or pharmaceutical intermediates, including pure enantiomers, purified peptides and proteins, compounds that are manufactured at the relatively large industrial scale of a few kilograms to several hundred tons per year. This development that has strongly affected the modem pharmaceutical industry is mainly due to the pioneering work of Csaba Horváth. His work in preparative HPLC was critical at both the practical and the theoretical levels. He was the first scientist in modem times to pay serious attention to the relationships between the curvature of the equilibrium isotherms, the competitive nature of nonlinear isotherms, and the chromatographic band profiles of complex mixtures. The thermodynamics of multi-component phase equilibria and mass transfer kinetics in chromatography attracted his interest and were the focus of ground-breaking contributions. He investigated displacement chromatography, an old method invented by Tiselius that Csaba was first to implement in HPLC. This choice was explained by the essential characteristic of displacement chromatography, in that it delivers fractions that can be far more concentrated than the feed. Remarkably, once the basics of nonlinear chromatography had been mastered in his group, most of the applications that were studied by his coworkers dealt with peptides of various sizes and with proteins. Thus, all the applications of preparative HPLC in the biotechnologies derive directly from Csaba's work. Although displacement did not pan out as a general method, the reasons are related more to practical constraints of the production of pharmaceuticals and to the long period of cheap energy that might be ending now. This report reviews Csaba's work in nonlinear chromatography.

Chromatography, High Pressure Liquid↗

Pharmaceutical applications of micelles in chromatography and electrophoresis.

This review surveys the use of micelles as separation media in chromatography and electrophoresis. Applications to pharmaceuticals whose molecular masses are relatively small are focused on in this review. In high-performance liquid chromatography (HPLC), chromatography using micelles and reversed-phase stationary phases such as octadecylsilylized silica gel (ODS) columns is known as micellar liquid chromatography (MLC). The main application of MLC to pharmaceutical analysis is the same as in ion-pair chromatography using alkylsulfonate or tetraalkylammonium. In most cases, selectivity is much improved compared with other short alkyl chain ion-pairing agents such as pentanesulfonate or octanesulfonate. Direct plasma/serum injection can be successful in MLC. Separation of small ions is also successful by using gel filtration columns and micellar solutions. In electrophoresis, especially capillary electrophoresis (CE), micelles are used as pseudo-stationary phases in capillary zone electrophoresis (CZE). This mode is called micellar electrokinetic chromatography (MEKC). Most of the drug analysis can be performed by using the MEKC mode because of its wide applicability. Enantiomer separation, separation of amino acids and closely related peptides, separation of very complex mixtures, determination of drugs in biological samples etc. as well as separation of electrically neutral drugs can be successfully achieved by MEKC. Microemulsion electrokinetic chromatography (MEEKC), in which surfactants are also used in forming the microemulsion, is successful for the separation of electrically neutral drugs as in MEKC. This review mainly describes the typical applications of MLC and MEKC for the analysis of pharmaceuticals.

Amino Acids↗

Continuous removal of protein aggregates by annular chromatography.

The removal of polymeric proteins from their monomers is a frequently encountered separation task, especially in the polishing step of therapeutic proteins. Continuous separation of protein polymers from monomers by annular chromatography using size exclusion chromatography has been studied regarding the resolution, recovery, fouling, and productivity and has been compared to conventional chromatography. An IgG preparation rich in aggregates was used as a model protein mixture. Under conditions that maximized the throughput, the polymers could be separated from the monomers, but baseline separation could not be achieved. Baseline separation was also not possible in batch mode using equivalent conditions, which was also confirmed by computer simulation. For separation of the aggregates from the product the entire available separation space (360 degrees ) was indispensable. Therefore only cyclic, discontinuous regeneration could be carried out. Loading was identified as a critical step, since the concentrated protein solution evaded into the headspace instead of migrating into the gel where viscous fingering often occurs in conventional chromatography. The productivity of annular chromatography was two times higher than that of the conventional batch chromatography, and the buffer consumption was reduced to half the conventional value. These two benefits are especially important for protein separation processes that suffer from low loadability, such as size exclusion chromatography. We have demonstrated that size exclusion can be performed on an industrial scale when it is run continuously with the aid of a pressurized annular chromatograph.

Chromatography, Gel↗

Purification of an antigenic vaccine protein by selective displacement chromatography.

A recent advance in the state of the art of displacement chromatography has been the development of selective displacement chromatography. In this process, the bioproduct of interest is selectively displaced while impurities with lower retention are eluted in the induced salt gradient and higher retained impurities are desorbed after the breakthrough of the displacer front. In this manuscript, selective displacement chromatography is employed to purify an antigenic vaccine protein (AVP) from an industrial process stream. Displacers were screened and an operating regime plot was employed to establish appropriate conditions for selective displacement. The selective displacement process was successful and resulted in AVP that was equivalent in purity to product obtained at commercial production scale after conventional step gradient chromatography. Methods used to characterize the purified protein include size-exclusion chromatography, SDS-PAGE, isoelectric focusing, N-terminal amino acid sequence analysis, and amino acid composition analysis. This is the first report of the purification of a commercially and pharmaceutically significant protein using selective displacement chromatography and thereby sets the stage for the implementation of selective displacement chromatography for the downstream processing of biologicals.

Amino Acid Sequence↗

Isolation and characterization of the affinity chromatography forms of human Glu- and Lys-plasminogens and plasmins.

Affinity chromatography forms, 1 and 2, were each isolated from human Glu- and Lys-plasminogens by gradient elution from a L-lysine-substituted Sepharose column with a linear gradient of epsilon-aminocaproic acid. Although each of the two zymogen forms contains two affinity chromatography forms, the relative concentrattions of these forms in each of the zymogen preparations depended upon the plasma sample or enriched plasma fraction used for the preparation of the zymogen. Specific analytical acrylamide gel electrophoretic systems were used for the characterization of the zymogen and enzyme forms, and their component affinity chromatography forms, 1 and 2. The four zymogen affinity chromatography forms, Glu-1-plasminogen, Glu-2-plasminogen, Lys-1-plasminogen, and Lys-2-plasmingoen, show distinct stepwise differences in their molecular size and charge. The Glu-1-form is the largest in molecular size and the most acidic, and the Lys-2-form is the smallest in molecular size and the most basic. The proteolytically altered Lys-1- and Lys-2- forms appear to be specifically df the zymogen affinity chromatography forms showed a different distribution of isoelectric forms. The major isoelectric forms isolated from Glu-plasminogen with pI values of 6.2, 6.3, 6.4, and 6.6, and the major isoelectric forms isolated from Lys-plasminogen with pI values of 6.7, 7.2, 7.5, 7.8, and 8.1, (Summaria, L., Arzadon, L., Bernabe, P., Robbins, K. C., and Barlow, G. H. (1973) J. Biol. Chem. 248, 2984-2991) were shown to be mixtures of the Glu-1- and Glu-2- forms, or the Lys-1- and Lys-2- forms, respectively. Although the sialic acid contents of the Glu- and Lys- forms appear to be similar, the isolated affinity chromatography forms show distinct differences. The sialic acid contents of the Glu-1- and Lys-1- forms are identical, and are substantially higher than the sialic acid contents of the Glu-2- and Lys-2- forms which are also identical to each other. It is possible that the charge difference between the zymogen-1- and -2- forms may be related to the differences in their sialic acid content. Each of the four zymogen affinity chromatography forms, when activated by urokinase in the presence of the plasmin inhibitor, Trasylol, was converted to an apparently unique and different enzyme form. The four enzyme forms show distinct stepwise differences in molecular size; Glu-1-plasmin is the largest in size whereas Lys-2-plasmin is the smallest in size. Each plasmin-derived carboxymethyl heavy(A) chain was found to be different in molecular size, but the two carboxymethyl light(B) chains found in each of the four enzyme forms appeared to be identical and of the same molecular sizes. The four heavy(A) chains show a stepwise difference in molecular size; the Glu-1-heavy(A) chain is the largest in size whereas the Lys-2-heavy(A) chain is the smallest in size...

Chromatography, Affinity↗

The determination of anticonvulsants in biological samples by use of high-pressure liquid chromatography.

The procedure for anticonvulsant analysis represent use of a relatively new technology. The procedures compare favorably in accuracy and precision with accepted methodology using gas chromatography [14]. It is possible to determine a greater number of anticonvulsants simultaneously with liquid chromatography than with reported gas-chromatographic procedures. This is because gas chromatography necessitates manipulation of the sample to be analyzed, the various components of which may have completely different manipulation requirements. Liquid chromatography is able to effect the analysis without extensive manipulation of the sample. The columns recommended in Sect. III are currently available standard columns. Column technology is developing at an accelerating rate. It is now anticipated that new developments in microparticulate packings and improvements in packing techniques will give the analyst greater column efficiency. This may be used either to shorten overall analysis time or to include more drugs in a simultaneous analysis. There is not yet available to the analyst a variety of different detectors suitable for routine use. This situation will change. In the case of the successful use of ultraviolet spectrophotometric detectors, the technique is not being fully exploited. Ultraviolet spectrophotometry is firmly established in practice, but as yet it is not routine to apply dual-wavelength spectroscopy to the column effluent. Application of this technique may be expected to improve selectivity and quantitation besides permitting optical resolution of some components that are not separated by the column. In the procedures given in this chapter there was no detailed discussion on gradient elution. This technique is potentially of great utility for simultaneous analyses of many compounds. It should be used only where isocratic elution is out of the question because it calls for somewhat stricter requirements of equipment in control of chromatography conditions. An additional time for equilibration between analyses may be considered too high a price to pay for any advantage gradient elution may give the analyst. The problem of fully automatic operation of liquid chromatographs for the type of analysis discussed here remains to be solved. Automatic operation would advance the use of liquid chromatography in the clinical laboratory probably more than any other single improvement. However, regardless of refinements of this type, liquid chromatography in its modern manifestation has versatility and sensitivity in abundance for analyzing compounds of toxicological and clinical interest. It will therefore assume greater importance in these areas.

Anticonvulsants↗

Analysis of benzo(a)pyrene:DNA adducts formed in cells in culture by immobilized boronate chromatography.

A chromatographic procedure using boronic acid residues linked to a cellulose support [(N-(N'-[m-(dihydroxyboryl)-phenyl]succinamyl)amino]ethyl cellulose), used by Sawicki et al. (Cancer Res., 43: 3212-3218, 1983) for analysis of 7,12-dimethylbenz(a)anthracene:DNA adducts, was modified to allow the analysis of benzo(a)pyrene (BaP):DNA adducts formed in cells in culture. Adducts resulting from reaction of 7 beta, 8 alpha-dihydroxy-9 alpha, 10 alpha-epoxy-7,8,9,10-tetrahydrobenzo(a)pyrene (anti-BaPDE) contain cis-vicinal hydroxyl groups that complex with the boronic acid residues; adducts resulting from 7 beta, 8 alpha-dihydroxy-9 beta, 10 beta-epoxy-7,8,9,10-tetrahydrobenzo(a)pyrene (syn-BaPDE) do not. A mixture of [3H]-syn-BaPDE:deoxyguanosine (dGuo) adduct and [14C]-anti-BaPDE:dGuo adduct was completely resolved on a column of boronate:cellulose. Early-passage cultures of Sencar mouse, Syrian hamster, and Wistar rat embryo cells and a culture of a human hepatoma cell line (Hep G2) were exposed to [3H]BaP, and the BaP:DNA adducts were resolved by boronate chromatography and high-performance liquid chromatography. The Hep G2 cells and mouse embryo cells contained two major adducts, a (+)-anti-BaPDE:dGuo adduct and a syn-BaPDE:dGuo adduct. Boronate chromatography permitted the resolution of an additional minor syn-BaPDE:deoxyribonucleoside adduct in the mouse embryo cells. The hamster and rat embryo cells contained a number of major BaP-DNA adducts that were resolved by boronate chromatography followed by high-performance liquid chromatography. The rat embryo cells contained three syn-BaPDE:deoxyribonucleoside adducts and approximately equal amounts of two adducts tentatively identified as dGuo adducts of the (+) and (-) enantiomers of anti-BaPDE. The boronate chromatography-high-performance liquid chromatography procedure improves the separation of the BaP:DNA adducts formed in biological systems and facilitates the identification of the BaP metabolite(s) responsible for the formation of these adducts.

Animals↗

Structural assessment of the N-linked oligosaccharides of cell-CAM 105 by lectin-agarose affinity chromatography.

The N-linked oligosaccharides of cell-CAM 105, a glycoprotein involved in the intercellular adhesion between rat hepatocytes, were studied by sequential lectin-agarose affinity chromatography of desialylated, [14C]-labelled glycopeptides. These glycopeptides were obtained by extensive pronase digestion followed by N-[14C]acetylation of the peptide moieties and desialylation by mild acid hydrolysis. Assuming that all glycopeptides were radiolabelled to the same specific radioactivity, Concanavalin A-Sepharose chromatography indicated that the majority of the glycans (84%) were of the complex-type of which approximately half were bi-antennary structures. The remainder of the glycans comprised oligomannose-type structures and/or incomplete bi-antennary structures. Pisum sativum lectin-agarose chromatography revealed that part of the bi-antennary glycans contained a fucose residue alpha(1-6)-linked to the N-acetylglucosamine which is attached to asparagine. Furthermore, the presence of tri-, and tetra- and/or tri'-antennary complex-type glycans was demonstrated by chromatography on immobilized Phaseolus vulgaris leukoagglutinating phytohemagglutinin and Aleuria aurantia lectin (AAL). AAL-agarose chromatography furthermore indicated the presence of alpha(1-3)-linked fucose in part of these glycopeptides, whereas no alpha(1-6)-linked fucose could be detected in these structures. The degree of beta-galactosylation of the complex-type glycans was investigated by chromatography on Ricinus communis agglutinin-agarose. The results indicated that only part of the bi-antennary glycans were completely beta-galactosylated. Similarly, at least three beta-galactose residues were present in only a part of the tri-, and tetra- and/or tri'-antennary glycans.

Adenosine Triphosphatases↗

Unified enantioselective capillary chromatography on a Chirasil-DEX stationary phase. Advantages of column miniaturization.

Immobilized Chirasil-DEX (mono-6-O-octamethylenepermethyl-beta-cyclodextrin chemically linked to dimethylpolysiloxane) can be employed as a versatile chiral stationary phase in chromatography. The chiral polymer has a long lifetime and is configurationally and thermally stable. The concept of unified enantioselective chromatography has been demonstrated for the enantiomer separation of hexobarbital by gas chromatography, supercritical fluid chromatography, liquid chromatography and capillary electrochromatography on a single open-tubular column (1 m x 50 microns I.D.) coated with Chirasil-DEX. The advantages of miniaturization in contemporary chromatographic enantiomer separation are demonstrated. Chirasil-DEX coated on porous silica is also useful for enantiomer separation in high-performance liquid chromatography.

Carbohydrate Sequence↗

Separation of catecholamines and their metabolites by adsorption, ion-pair and soap chromatography.

The separation of catecholamines and their metabolites has been carried out by high-performance liquid chromatography using three systems: liquid-solid adsorption, ion-pair partition, and soap chromatography. In the last newly developed technique a reversed-phase packing is used in conjunction with an aqueous organic eluent containing a detergent. The detergent is chosen so that its ion can form ion-pairs with ions of the solutes. Soap chromatography proved the best technique in terms of column efficiency (giving 3000-5000 plates in 125 mm), resolution and sensitivity of detection. Noradrenaline, adrenaline and dopamine, their 3-O-methyl derivatives, L-3,4-dihydroxyphenylalanine, homovanillic acid and other related compounds could be separated in less than 10 min at the 10-50-ng level on columns whose plate heights were in the range of 20-40 mum. The dependence of retention on the concentration of organic modifier and on detergent concentration for three anionic detergents is reported. The method is applied to the direct analysis of urine and the potential of the method for such analyses, especially of pathological urines is demonstrated. Soap chromatography is likely to enlarge the scope of application of high-performance liquid chromatography to biochemical analysis. It is a powerful method for the separation of ionizable compounds which could replace conventional ion-exchange chromatography.

Adsorption↗

Purification of oestrogen synthetase by high-performance liquid chromatography. Two membrane-bound enzymes from the human placenta.

Human placental NADPH-cytochrome P-450 reductase, obtained by 2',5'-ADP-Sepharose affinity chromatography, was separated into two reductase-active peaks on a Pharmacia Mono-Q column. By this short, two-step chromatographic procedure, the two reductases were obtained in a homogeneous state with high retention of activity and in over 900-fold purification. Aromatase-reconstituting activity was present only in the higher-molecular-weight reductase (79 000 D), not in the smaller, 70 000 D reductase, which turned out to be a proteolysis product of the former. Both proteins were eluted as a single peak in reversed-phase high-performance liquid chromatography on a Protesil-diphenyl column. Similar results were obtained with bovine hepatic NADPH-cytochrome P-450 reductases. On the other hand, starting from a reductase-free preparation, we have obtained by high-performance ion-exchange chromatography and high-performance size-exclusion chromatography, only partial purification of the aromatase cytochrome P-450, which showed the following values: aromatase activity, 3.995 nmol/min/mg protein (60-fold purification); cytochrome P-450 content, 1.376 nmol/mg protein (23-fold purification); molecular weight, 165 000 D (estimated as an aggregate by size-exclusion chromatography). Although complete purification of the aromatase component has yet to be accomplished, our results suggest that high-performance ion-exchange chromatography on a Mono-Q column is very useful for the purification of acidic, membrane-bound enzymes with good retention of activity.

Ammonium Sulfate↗

Use of size-exclusion and ion-exchange high-performance liquid chromatography for the isolation of biologically active growth factors.

Size-exclusion and ion-exchange high-performance liquid chromatography were used to purify biologically active growth factors as measured by the ability of the factors to stimulate DNA synthesis in 3T3 cells. Chromatography was performed in aqueous buffer and at neutral pH to avoid possible inactivation of biological activity. The growth factors analyzed were chondrosarcoma growth factor (CHSA-GF), human milk growth factor (HMGF), retinal-derived growth factor (RDGF) and mouse epidermal growth factor (EGF). CHSA-GF, HMGF, and RDGF were eluted from TSK 2000 columns as well-defined peaks of activity with molecular weights of 12,000-15,000, 5000-6000, and 16,000-18,000, respectively. EGF was found to have an abnormally low molecular weight after chromatography on TSK 2000. However, incorporation of guanidine . HCl into the TSK column resulted in the elution of EGF at its known molecular weight of ca. 6000. Anion-exchange high-performance liquid chromatography on AX 300 was used for the purification of HMGF and RDGF, and cation-exchange high-performance liquid chromatography on CM 300 was used for the purification of CHSA-GF. The results show that size-exclusion and ion-exchange chromatography can be used without organic solvents or extremes in pH to purify a number of different growth factors successfully with retention of biological activity.

Animals↗

Influence of the nature of coupling agents on insulin adsorption on supports grafted with sialic acid for high-performance affinity chromatography.

Porous silica exhibits excellent mechanical properties for use as a stationary phase for high-performance liquid chromatography. However, negative surface charges make it unusable in its native state. For this reason, silica beads are coated with dextran polymers carrying a calculated amount of diethylaminoethyl groups. Both the minimization of non-specific interactions and the hydrophilic character of such supports allow their functionalization with biospecific ligands and finally their use in high-performance affinity chromatography of biological products. The use of these modified supports in high-performance affinity chromatography requires a better understanding of various characteristics of stationary phases. For this purpose, several techniques were utilized, in particular, size-exclusion chromatography and adsorption of radiolabelled albumin. These methods provided complementary information on the structure of these supports. Coated silica-based supports were functionalized with sialic acid by means of different coupling agents. The affinity of these supports for insulin was determined by the establishment of adsorption isotherms and by high-performance affinity chromatography, to evidence the relationships between structural characteristics of the supports and their separation properties. The study of interactions between these supports and insulin allowed us to show the importance of the coupling method on the performances of supports in affinity chromatography.

Adsorption↗

Nondestructive detection of neutral glycosphingolipids with lipophilic anionic fluorochromes and their employment for preparative high-performance thin-layer chromatography.

In this study a simple and effective procedure for the isolation of individual neutral glycosphingolipids (GSLs) by preparative thin-layer chromatography is described. The method is based on nondestructive visualization of neutral GSLs on silica gel precoated thin-layer chromatography plates with anionic lipophilic fluorochromes. After thin-layer chromatography, individual neutral GSLs were detected by spraying the plate with fluorochrome solution followed by exposure to ultraviolet light. GSL containing silica gel was scraped off and extracted with chloroform:methanol:water (30:60:8, by vol). Neutral GSLs were freed from contaminating anionic fluorochrome by DEAE-Sepharose anion-exchange chromatography. Finally, a stepwise chloroform:methanol gradient chromatography on a small silica gel K60 column was employed to remove non-GSL impurities. Of nine different anionic fluorochromes tested, 2-(N-methylanilino)-naphthalene-6-sulfonic acid was found to be the most suitable for preparative purposes. The method was proved with reference GSL mixtures containing glucosyl-, galactosyl-, lactosyl-, globotriaosyl-, and neolactotetraosylceramides, each substituted with C24- and C16-fatty acids, resulting in isolation of individual GSL fractions. The technique was applied for the purification of neutral GSLs from mouse kidney and human granulocytes carrying Lewisx-epitopes. In summary, the method described offers an easy to handle and successful preparative thin-layer chromatography strategy to obtain pure neutral GSLs in microgram and milligram quantities.

Anilino Naphthalenesulfonates↗

Detection, isolation and characterization of staphylococcal enterotoxin B in protein A preparations purified by immunoglobulin G affinity chromatography.

Studies were performed to detect and isolate trace contaminants of staphylococcal enterotoxin B (SEB) in various protein A preparations isolated by affinity chromatography employing human IgG covalently bound to Sepharose 4B. Utilizing an ELISA technique, trace amounts (0.018-0.138%) of SEB could be detected in protein A preparations after separation of the SEB employing a molecular sizing column in a high pressure liquid chromatography (HPLC) system. Trace contamination by SEB could be removed from protein A preparations by an additional DEAE ion exchange chromatography step employing a low ionic strength buffer system (0.005 M NaCl in 0.01 phosphate buffer, pH 7.50). The resulting protein A preparations possessed a purity higher than that observed prior to the final purification step. Polyacrylamide gel electrophoresis (PAGE) analyses of the trace contamination removed from protein A preparations by ion exchange chromatography revealed, in addition to SEB, several additional contaminating polypeptides of an unknown nature. These studies indicate that protein A preparations of high purity can be prepared by employing DEAE ion exchange chromatography in addition to affinity chromatography utilizing immobilized human IgG.

Chromatography, Affinity↗