Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

[Determination of sulbactam in human serum using capillary isotachophoresis].

A method of determination of sulbaktam in human serum by capillary isotachophoresis with the use of a conductivity detector was worked out. Prior to the proper analysis, a pretreatment of the sample of serum was carried out by extracting sulbaktam to butyl acetate. The total yield of the proposed analytical procedure with an extraction first stage approaches 94%. The smallest determinable amount of the sample corresponds to 1 micrograms of sulbaktam in 1 ml of serum. The reported method was employed to evaluate the samples of sera of volunteers after intravenous administration of the dosage form sulbaktam-ampicillin (VUFB) and the foreign pharmaceutical preparation Unasyn (Pfizer). Statistically insignificant differences in pharmacokinetic parameters have confirmed that the preparations are highly bio-equivalent.

Electrophoresis↗

Electrothermal atomic absorption determination of aluminum in tissues dissolved in tetramethyl ammonium hydroxide.

In this rapid, precise method for the accurate determination of aluminum in biological tissue, the only preparative step required is the dissolution of the sample in hot aqueous tetramethyl ammonium hydroxide, followed by dilution with ethanol. Aluminum is measured by electrothermal (graphite furnace) atomic absorption spectroscopy, with direct reference to aqueous standards. The CVs for the method within-day and day-to-day are 3.0% and 6.8%, respectively. Analytical recovery of added aluminum is 86 to 108%, and matrix effects are minimal. Measurement of aluminum in tissue from normal laboratory rats and rats injected with aluminum gave values close to those found by an acid digestion method, but higher than those obtained by extraction with a saturated solution of ethylenediaminetetraacetate.

Aluminum↗

Serum and cytosolic levels of CA549 in breast cancer patients.

CA 549 is a new mucinous circulating tumor marker recognized by two monoclonal antibodies (BC4E549 and BC4N154) recently proposed for breast cancer. In this report we compared the levels of CA 549 and CA 15.3, the best known biomarker for breast cancer nowadays, in 68 sieric and 59 cytosolic samples. Serum samples came from 59 breast patients (24 with primary disease = M-, 18 with systemic disease = M+, 17 with no evidence of disease after surgery = NED) and 9 women with benign breast disease = BBD. The cytosols were prepared from primary breast carcinomas according to the method used for hormonal receptors. At first we evaluated the analytical performance of the immunoradiometric assay for CA 549 (Hybri-BREScan, Hybritech) and its applicability to the cytosolic determination. Using a cut-off value of 12 U/mL for CA 549 and 28 U/mL for CA 15.3 serum levels, we obtained the following percentages of positivities: M- = 21%; M+ = 83%; NED = 0%; BBD = 22% for CA 549 and M- = 33%; M+ = 89%; NED = 18%; BBD = 22% for CA 15.3. CA 549 gave information concordant with CA 15.3 in a high percentage of cases both in sera and in cytosols, but the clinical relevance of cytosolic determination remains to be investigated. Since serum CA 549 showed an adequate sensitivity in M+ patients only, it may be proposed in the follow-up to confirm CA 15.3 abnormal values or as an alternative to it.

Antibodies, Monoclonal↗

Glutamate optical biosensor based on the immobilization of glutamate dehydrogenase in titanium dioxide sol-gel matrix.

A simple and novel titania sol-gel derived optical biosensor coupled with carboxy seminaphthorhodamine-1-dextran (SNARF-1-dextran) as the fluorescent dye was fabricated for the determination of glutamate in water and biological samples. The NADH-dependent glutamate dehydrogenase (GLDH) was trapped in titania sol-gel derived matrix prepared by vapor deposition method. In addition, scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to characterize the surface morphology of the spots. SEM and AFM images showed that the deposition of titania precursor at 27 degrees C for 6.5h was found to be suitable to form transparent titania sol-gel matrix to encapsulate GLDH and fluorescent probe. AFM images showed that the roughness of TiO(2) surface increased from 2.16 nm in the absence of GLDH and SNARF to 37.8 nm after the immobilization. The developed titania biosensor has good analytical performance with water samples. A dynamic range between 0.04 and 10mM with the detection limit of 5.5 microM were observed. The responses to glutamate in biological samples also showed good performances, and the dynamic range and detection limit were 0.02-10mM and 6.7 microM, respectively. High precision with relative standard deviations of 4.2 and 10.7% in water and biological samples, respectively, were also demonstrated. In addition, the biosensor showed a relatively high storage stability over more than 1 month. Results obtained in this study clearly demonstrate that this simple vapor deposition method can be successfully used to form transparent titania sol-gel film for the fabrication of glutamate biosensors that are suitable for optical detection of glutamate in water and biological samples.

Biosensing Techniques↗

Separation of proteins with a molecular mass difference of 2 kDa utilizing preparative double-inverted gradient polyacrylamide gel electrophoresis under nonreducing conditions: application to the isolation of 24 kDa human growth hormone.

A method for separating proteins with a molecular mass difference of 2 kDa using SDS-PAGE under nonreducing conditions is presented. A sample mixture containing several human growth hormone (hGH) isoforms was initially separated on a weak anion-exchange column. Fractions rich in 24 kDa hGH as determined by analytical SDS-PAGE were pooled and further separated by cation-exchange chromatography. The fractions pooled from the cation-exchange chromatography contained two hGH isoforms with a 2 kDa molecular mass difference according to SDS-PAGE analysis, 22 and 24 kDa hGH. The 22 and 24 kDa hGH were separated using continuous-elution preparative double-inverted gradient PAGE (PDG-PAGE) under nonreducing conditions. The preparative electrophoresis gel was composed of three stacked tubular polyacrylamide matrices, a 4% stacking gel, a 13-18% linear gradient gel, and a 15-10% linear inverted gradient gel. Fractions containing purified 24 kDa hGH were pooled and Western blot analysis displayed immunoreactivity to antihGH antibodies. PDG-PAGE provides researchers with an electrophoretic technique to preparatively purify proteins under nonreducing conditions with molecular mass differences of 2 kDa.

Chromatography↗

Quantitative analysis of a model opioid peptide and its cyclic prodrugs in rat plasma using high-performance liquid chromatography with fluorescence and tandem mass spectrometric detection.

Two analytical methods were developed for quantitative determination of DADLE (H(2)N-Tyr-D-Ala-Gly-Phe-D-Leu-COOH) and its two cyclic prodrugs in rat plasma. For high-performance liquid chromatography with fluorescence detection (LC-FLU), precolumn derivatization of DADLE was accomplished by labeling the N-terminal amino group with the reagent naphthalene-2,3-dicarboxaldehyde in the presence of cyanide (NDA/CN) to form a highly fluorescent 1-cyanobenz[f]isoindole (CBI) derivative. A multi-dimensional LC system was employed to improve selectivity, and solid-phase extraction (SPE) was used for plasma sample preparation. The cyclic prodrugs were converted to DADLE prior to their derivatization. With fluorescence detection after derivatization, the limit of quantitation (LOQ) was 6 ng ml(-1) for the analysis of DADLE, and good linearity was observed up to 6000 ng ml(-1) in rat plasma. Quantitative analysis of DADLE and its cyclic prodrugs was also performed using liquid chromatography interfaced to electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS). Chromatographic separation was achieved on a C(18) column using gradient elution in a water-acetonitrile system containing 0.1% (v/v) formic acid. The tandem mass spectrometric analysis was performed in the multiple reaction monitoring mode using internal standardization to improve assay precision and accuracy. For plasma sample pretreatment, acetonitrile was added first to precipitate proteins and SPE was used to minimize matrix effects. Using LC-ESI-MS-MS, the LOQ was 0.5 ng ml(-1) for DADLE and 2 to 5 ng ml(-1) for its prodrugs. Good linearity was observed from the LOQ up to 1000 ng ml(-1) for all compounds. For the analysis of DADLE, both analytical methods showed good precision, accuracy and stability. However, for prodrug analysis, LC-FLU showed some sensitivity and accuracy problems, while the LC-ESI-MS-MS method provided consistent and satisfactory results. In conclusion, LC-ESI-MS-MS is the method of choice for the analysis of DADLE and its cyclic prodrugs in rat plasma samples due to its good selectivity, high sensitivity, and fast analysis. Its application was demonstrated through biodisposition and bioconversion studies of the coumarinic acid-based prodrug after intravenous administration in rats.

Animals↗

Accuracy and biological variation of human serum paraoxonase 1 activity and polymorphism (Q192R) by kinetic enzyme assay.

BACKGROUND: Paraoxonase 1 (PON1) phenotype is a better predictor of atherosclerosis risk than are PON1 genetic polymorphisms alone. Larger studies are required to determine the role of PON1 and there is a need for standardized PON1 assays between laboratories. METHODS: We have adapted 5 enzyme kinetic assays for high-throughput automated analysis of PON1 activity. Using different substrates and reaction conditions, we measured PON1 activity and used activity ratios to identify the PON1 Q192R genetic polymorphisms and assessed the accuracy of the genotype assignments in 79 adult study participants by comparing them with genotypes determined by AlwI restriction enzyme digestion of a 176-bp PCR amplification product from genomic DNA. Imprecision was determined using pooled serum and purified enzyme preparations. Biological variability was estimated by analysis of serial samples from 17 individuals. Variability parameters were compared with total cholesterol as a point of reference to a recognized biomarker of coronary heart disease risk. RESULTS: Salt stimulation and inhibition ratios were 97.4% and 94.7% correct in assigning Q192R genotype, respectively. Analytical imprecision (CV) was 1.0%-3.0% for phenylacetate and paraoxon substrate assays and 3.0%-8.0% for the para-nitrophenylacetate substrate assays. Combination of the 2 ratios into a double ratio resulted in 100% correct genotype classification. CONCLUSION: The described methods for measurement of PON1 activity and accurate genotype assignment are rapid and have potential to facilitate the efficient investigation of PON1 status in clinical and epidemiological studies.

Adult↗

Determination of melanotan II in rabbit urine using solid-phase extraction sample preparation followed by reversed-phase high-performance liquid chromatography.

A solid-phase extraction (SPE) method has been developed for the isolation of melanotan II from rabbit urine. The proposed extraction method makes it possible to selectively isolate melanotan II without significant loss of the peptide. Standard curves obtained from high-performance liquid chromatographic (HPLC) analysis of spiked urine extracts are linear from 0.1 to 4.0 micrograms/ml. The analytical method is shown to be highly reproducible, giving a relative standard deviation of less than 5% for both between-day and same-day analyses. The accuracy of the method obtained from standard plots ranges from -3.3 to 3.1%.

Animals↗

Determination of polycyclic aromatic compounds in fish tissue.

A method is presented for the analysis of polycyclic aromatic hydrocarbons (PAHs), polycyclic aromatic sulfur heterocycles (PASHs), and basic polycyclic aromatic nitrogen heterocycles (PANHs) in fish. The analytical procedure includes Soxhlet extraction of prepared fish tissue with methylene chloride followed by gel permeation chromatography (GPC) using Bio-beads SX-3. For PAHs/PASHs, further cleanup is performed using adsorption chromatography on Florisil (5% water deactivated) and elution with hexane. For basic PANHs further cleanup of the fish extracts after GPC is achieved using liquid-liquid partitioning with 6 M hydrochloric acid and chloroform and then basifying the aqueous phase and extracting it with chloroform. Analysis of fortified fish samples was performed using capillary gas chromatography with flame ionization detection and capillary gas chromatography-mass spectrometry. Good agreement was observed for both methods of analysis when applied to fish samples fortified with PAHs, PASHs and basic PANHs at 0.1 to 1 microgram/g, suggesting that the method is effective at removing interfering biogenic compounds prior to analysis. Average recovery of PAHs/PASHs from fortified fish tissue was 87% and 70% for fish tissue fortified at 0.24-1.1 and 0.024-0.11 microgram/g, respectively. Average recovery for basic PANHs was 97% for fish fortified at 1.2-1.4 micrograms/g.

Animals↗

[The use of high-performance liquid chromatography in biochemical and medical analyses (author's transl)].

The HPLC (high-performance liquid chromatography) is applicable for all biochemical analyses, because of the wide variety of separation principles (adsorption-, partition-, ion-exchange- and steric exclusion-chromatography). Of exceptional importance is the reversed phase technique, a special case of partition chromatography. The sensitivity of detectors depends upon the structure of the respective substance, but is ordinarily lower -- apart from fluorescence detection -- than GLC-detectors. The development of new systems is going on. The HPLC is used in the quantitative determination of plasma levels of drugs and their metabolites. This is of special importance during the development of new drugs and for monitoring therapy. The measurement of concentrations of certain biogenic substances helps in diagnosis. An important field of application of HPLC is the use in sample clean-up for other analytical methods. In this application HPLC surpasses all other chromatographic techniques by fastness, reproducibility and suitability for automation.

Adsorption↗

Methods for chromatographic and electrophoretic separation and assay of NADP oxidoreductases.

The different techniques described in purification protocols for pyridine nucleotide-dependent enzymes have been reviewed, covering mainly the papers published in the past six years. Chromatography was reported in 100% of reviewed papers and among the chromatographic techniques, affinity chromatography was the most used (ca. 92%), followed by ion-exchange chromatography (ca. 79%), size-exclusion chromatography (ca. 64%) and hydrophobic chromatography (ca. 24%). Other chromatographic techniques were used infrequently. Each chromatographic technique has a different specific capacity and chemical selectivity and, therefore, the order of selection should be based on a precise knowledge of the nature of the sample and the amount of the target enzyme that it contains. Analytical electrophoresis was used in about 95% of the reviewed papers, with denaturing polyacrylamide gel electrophoresis (PAGE) being the most widely used mode (ca. 92%), followed by native PAGE (ca. 48%). The use of isoelectric focusing was reported in 14% of the papers, while preparative gel electrophoresis was used in only 8% of the cases. The use of other electrophoretic techniques was reported in only a few papers. The use of continuous enzymatic activity assay methods (spectrophotometric) was found in most papers, while high-performance liquid chromatography-based methods (discontinuous assays) were reported in only 11% of the reviewed articles.

Chromatography↗

The use of nuclear magnetic resonance spectroscopy in the detection of drug intoxication.

The use of nuclear magnetic resonance (NMR) spectroscopy as a method for drug analysis has the advantages of reduced pre-analytical preparation time and the potential to detect and quantitate drug conjugates and metabolites simultaneously. NMR was investigated as a method to screen for organic substances (and metabolites) in 25 patients who presented to the Emergency Department with clinical indications of a drug overdose. Urine specimens were examined by 1H NMR spectroscopy at 300 MHz and the results compared with gas chromatography-mass spectrometry (GC-MS) results. There was a 56% concordance (14 of 25 samples) between NMR and GC-MS. NMR identified acetaminophen, ibuprofen, aspirin, valproate, carbamazepine, and pseudoephedrine as parent compounds or metabolites. For a patient for whom GC-MS results were negative, NMR strongly suggested the presence of erythromycin. NMR was most successful in identifying analgesics and antiepileptic drugs (sensitivity 83-100%). In 10 patients, signals from 1,2-propanediol, a common vehicle for some pediatric medications, were observed by NMR spectroscopy. NMR had 0% sensitivity in identifying tricyclic antidepressants and antipsychotic drugs. In these samples, GC-MS detected a variety of compounds, including tricyclic antidepressants and their metabolites and chlorpromazine. In addition, other substances that had not been disclosed as having been ingested, such as caffeine, diphenhydramine, and nicotine, were detected by GC-MS. NMR spectroscopy represents an emerging supplementary analytical technique that is applicable to a wide range of possible intoxicants and to the evaluation of the intoxicated patient, particularly when larger amounts of the intoxicant (> 200 mg) are ingested.

Adolescent↗

Direct cocktail analysis of drug discovery compounds in pooled plasma samples using liquid chromatography-tandem mass spectrometry.

Direct plasma injection technology coupled with a LC-MS/MS assay provides fast and straightforward method development and greatly reduces the time for the tedious sample preparation procedures. In this work, a simple and sensitive bioanalytical method based on direct plasma injection using a single column high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) was developed for direct cocktail analysis of double-pooled mouse plasma samples for the quantitative determination of small molecules. The overall goal was to improve the throughput of the rapid pharmacokinetic (PK) screening process for early drug discovery candidates. Each pooled plasma sample was diluted with working solution containing internal standard and then directly injected into a polymer-coated mixed-function column for sample clean-up, enrichment and chromatographic separation. The apparent on-column recovery of six drug candidates in mouse plasma samples was greater than 90%. The single HPLC column was linked to either an atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI) source as a part of MS/MS system. The total run cycle time using single column direct injection methods can be achieved within 4 min per sample. The analytical results obtained by the described direct injection methods were comparable with those obtained by semi-automated protein precipitation methods within +/- 15%. The advantages and challenges of using direct single column LC-MS/MS methods with two ionization sources in combination of sample pooling technique are discussed.

Chromatography, High Pressure Liquid↗

Direct quantitative analysis of phthalate esters as micro-contaminants in cleanroom air and wafer surfaces by auto-thermal desorption--gas chromatography--mass spectrometry.

This study established an analytical method for the trace analyses of two phthalate esters, including diethyl phthalate (DEP) and di-n-butyl phthalate (DBP), known as the major constituents of cleanroom micro-contamination detrimental to the reliability of semiconductor devices. Using thermal desorption coupled with a GC-MS system, standard tubes were prepared by delivering liquid standards pre-vaporized by a quasi-vaporizer into Tenax GR tubes for calibration. This method was capable of achieving detection limits of 0.05 microg m(-3) for 0.1 m3 air samples and 0.03 ng cm(-2) for 150-mm wafer surface density. Actual samples collected from a semiconductor cleanroom showed that the concentration of DBP in a polypropylene wafer box (0.45 microg m(-3)) was nearly four times higher than that in the cleanroom environment (0.12 microg m(-3)). The surface contamination of DBP was 0.67 ng cm(-2) for a wafer stored in the wafer box for 24 h. Furthermore, among the three types of heat-resistant O-ring materials tested, Kalrez was found to be particularly suitable for high-temperature processes in semiconductor cleanrooms due to their low emissions of organic vapors. This analytical procedure should serve as an effective monitoring method for the organic micro-contamination in cleanroom environments.

Air Pollutants↗

Determination of gamma-hydroxybutyric acid in biological fluids by using capillary electrophoresis with indirect detection.

gamma-Hydroxybutyric acid (GHB) is a central nervous system (CNS) depressant and hypnotic which, in recent times, has shown an increasing abuse either as recreational drug (due to its euphoric effects and ability to reduce inhibitions) or as doping agent (enhancer of muscle growth). Analogues of GHB, namely gamma-butyrolactone (GBL) and 1,4-butanediol (1,4-BD), share its biological activity and are rapidly converted in vivo into GHB. At present, GHB and analogues are placed in the Schedules of Controlled Substances. Numerous intoxications in GHB abusers have been reported with depressive effects, seizures, coma and possibly death. The purpose of the present work was the development of a rapid analytical method based on capillary zone electrophoresis for the direct determination of GHB in human urine and serum at potentially toxic concentrations. Analytical conditions were as follows. Capillary: length 40 cm (to detector), 75 microm i.d.; buffer: 5.0 mM Na(2)HPO(4), 15 mM sodium barbital adjusted to pH 12 with 1.0 M NaOH; voltage: 25 kV at 23 degrees C; indirect UV detection at 214 nm; injection by application of 0.5 psi for 5 s. alpha-Hydroxyisobutyric acid was used as internal standard (IS). Sample pretreatment was limited to 1:8 dilution. Under these conditions, the sensitivity was approximately 3.0 microg/ml (signal-to-noise ratio >3). Calibration curves prepared in water, urine and serum were linear over concentration ranges 25-500 microg/ml with R(2)>/=0.998. Analytical precision was fairly good with R.S.D.<0.60% (including intraday and day-to-day tests). Quantitative precision in both intraday and day-to-day experiments was also very satisfactory with R.S.D.</=4.0%. No interferences were found neither from the most common "drugs of abuse" nor from endogenous compounds. In conclusion, capillary electrophoresis can offer a rapid, precise and accurate method for GHB determination of biological fluids, which could be important for screening purposes in clinical and forensic toxicology.

Calibration↗

High-throughput approaches to the quantitative analysis of ketoconazole, a potent inhibitor of cytochrome P450 3A4, in human plasma.

Ketoconazole, an imidazole-piperazine compound, is an orally active antimycotic agent. In addition, ketoconazole is a specific inhibitor of cytochrome P450 3A4. As about 60% of oxidized drugs are biotransformed by this isoform, the potential effect of a concomitant administration of ketoconazole on drug disposition may be of interest during drug development. The present paper describes three different approaches (methods A, B, and C) to attain high-throughput sample preparation and analysis in the quantification of ketoconazole in human plasma. Method A consisted of acetonitrile precipitation in a 96-well plate, transfer of the supernatant via a Tomtec Quadra 96 Model 320, and subsequent injection onto a 50 x 4.6 mm (i.d.) Develosil Combi-RP-5 column (packed with C30 bonded silica particles). Method B consisted of an identical sample preparation to method A with the exception that a Michrom Magic Bullet(trade mark) column, 2.0 --> 0.50 mm (i.d., tapered bore) x25 mm length, was used. Lastly, in method C, a turbulent-flow chromatography (TurboFlow LC/APCI-MS/MS) module was used for the direct analysis of ketoconazole in human plasma. A Sciex API 3000 was used in methods A and B, while a Micromass Quattro LC was employed in method C. Based on the values obtained for the calibrator (standard) and quality control samples, all three protocols yielded satisfactory accuracy, precision, and reduced manual sample preparation time.

Antifungal Agents↗

Chromatographic separation of carotenoids.

The carotenoids are extremely reactive and consequently unstable due to their long system of conjugated double bonds. Several precautions, such as protection against light and oxygen, use of low temperature and antioxidants, analysis in the shortest possible time, should be taken during isolation and chromatography. The food samples, preferably fresh, are homogenized and immediately extracted with a suitable organic solvent. Saponification has been employed in order to hydrolyze the carotenoid esters, remove fatty material and destroy chlorophyll. This optional step facilitates subsequent carotenoid separation, identification and quantification. The separation of carotenoids is usually carried out by column chromatography, thin layer chromatography and high performance liquid chromatography, in analytical or preparative scale, on many stationary phases such as silica-gel, alumina, MgO, Ca(OH)2 and reversed-phase material (C18 and C30). The choice of the most suitable chromatographic method depends on the amount of sample, carotenoid composition, resolution, speed and purity required. Examples of carotenoid separation in different stationary phases will be shown and discussed.

Carotenoids↗

Fluorimetric liquid chromatographic analysis of amantadine in urine and pharmaceutical formulation.

A simple and sensitive liquid chromatographic method is described for the analysis of amantadine and memantine. The method is based on the derivatization of amantadine and memantine extracted from alkalified samples with (2-naphthoxy)acetyl chloride at mild conditions. The resulting derivatives were analyzed by isocratic HPLC with a fluorimetric detector (lambdaex, 227 nm; lambdaem, 348 nm). The linear range for the determination of amantadine or memantine spiked in urine (1.0 ml) was 1.0-10.0 nmol with a detection limit of about 0.2 nmol (S/N = 3; injected sample 20 microl). Only amantadine preparations are available on our local market, and application of the method to the analysis of amantadine in formulation and in the urine of a dosed subject was demonstrated and proved feasible. Quantitation of AT in tablets or capsules is capable in the linear range of 2.0-50.0 microM. Toluene was used as the solvent for extracting amantadine or memantine in samples and the resulting toluene extract was directly subjected to subsequent derivatization without solvent replacement leading to a simpler analytical procedure.

Amantadine↗