Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

Color stability of provisional restorative materials after accelerated aging.

PURPOSE: Color of 11 provisional restorative materials (4 acrylic resins and 7 resin composites) was evaluated by reflection spectrophotometry immediately after fabrication, after aging for 15 kJ/m(2), and after aging for 60 kJ/m(2) to determine relative color stability under experimental aging conditions. MATERIALS AND METHODS: Specimens of provisional restorative materials were polymerized according to manufacturers' instructions and aged in an artificial aging chamber with exposure to a total ultraviolet irradiation of 60 kJ/m(2) in increments of 15 kJ/m(2). Color was measured by CIE L*a*b* on a reflection spectrophotometer before and after aging. Color change (Delta E*) was calculated and analyzed statistically by analysis of variance with repeated measures after 15 and 60 kJ/m(2) intervals of aging. RESULTS: Statistically significant changes in color were observed after accelerated aging at both the initial and final aging intervals. Five of the 11 provisional materials tested showed perceptible color change (Delta E* from 3.6 to 9.3) after accelerated aging of 15 kJ/m(2). Seven of the 11 provisional materials tested showed perceptible color change (Delta E* from 3.4 to 9.4) after accelerated aging of 60 kJ/m(2). CONCLUSIONS: Clinically perceptible color changes (Delta E* Delta 3.3) can be expected in some acrylic resin and composite resin provisional materials after accelerated aging.

Acrylic Resins↗

Degree of conversion in denture base materials for varied polymerization techniques.

New processing techniques for denture base acrylic resins have been introduced which have not comparatively quantified the residual monomer content. While proper processing keeps the residual monomer in a tolerable range for most patients, tissue irritation and reaction due to potentially higher residual monomer in these alternative techniques could be a clinical concern. Decreased degree of conversion may influence physical properties as well as biocompatibility. This investigation evaluated the residual monomer content of acrylic resins cured by three different polymerization modes. Materials (polymerization system) evaluated were: Lucitone 199 (conventional process), Accelar 20 (rapid boil-out), and Acron MC (microwave). Fourier transform infrared spectrometry (FTIR) was employed to determine the degree of conversion. All curing methods produced similar results (Lucitone 199 = 92.7% (0.21), Acron MC = 92.6% (0.57), Accelar 20 = 90.9% (0-73). Conversion for Accelar 20 (rapid boil-out technique), though statistically different (P < 0.05, ANOVA) from the other two materials and polymerization techniques, was only slightly less. It is unlikely that the rapid boil-out technique would induce more adverse tissue responses than the other techniques included in this study.

Acrylic Resins↗

[Detection of cytotoxicity of biocompatible materials in MRC-5, HeLa, and RC-IAL cell lines].

The sensitivity of diploid and heteroploid cell lines for detection of cytotoxicity using the agar diffusion method on cell culture, was tested with ascorbic acid solution of different concentrations. A total of 562 samples of 21 various materials were tested. The heteroploid cell line, RC-IAL, showed in relation to the MRC-5 and HeLa cell lines, greater sensitivity because it showed the presence of cytotoxic effect with the lowest concentration used (10 and 25 micrograms/ml) of ascorbic acid and showed greater diameter of cytotoxic halo in 15 samples and equal diameter in 16 of the 43 positive samples (7.6%). Out of 43 positive samples, the MRC-5 line did not show cytotoxicity in 3 sponge samples and 1 of acrylic resin. The PVC (polyvinylchloride) and polyethylene rarely showed positivity, while, the plastic, cotton and acrylic resin demonstrated cytotoxicity in about 5% of samples. We thus suggest the use of the RC-IAL and HeLa cell lines for continuation of this type of analysis at Adolfo Lutz Institute.

Animals↗

A new visible light-cured resin system applied to removable prosthodontics.

Preliminary studies of VLC resins have produced promising results; however, additional research is necessary to completely define qualities of this material. Biologic testing of VLC (Triad) resins indicated that they are nontoxic and biocompatible. They have a wide range of uses in all subdisciplines of prosthodontics. Advantages such as accuracy of fit, superior strength, complete polymerization without residual compounds, ease of fabrication and manipulation, patient acceptance, ability to bond with other denture base resins, and low bacterial adherence make this material an important addition to the choices available to dentists. As with many new materials, there are initial problems or hurdles that must be overcome before there is widespread use. Initial formulations of material had insufficient flexural strength and tended to fracture when flexed over uncut sites on a stone cast. This problem has been reduced by Dentsply International, Inc. with the introduction of the new improved formulation. The original VLC bonding agent did not provide sufficient bond strength with acrylic resin denture base materials, but this also has been improved with development of a new VLC bonding agent. The problem of microporosity and small voids produced when adapting VLC resin sheets against a stone cast may be overcome with pressure or vacuum adaptation techniques. A promising application of VLC resin material is in direct intraoral procedures such as relining of dentures. Physical and chemical properties are superior to autopolymerizing methacrylates. Preliminary studies have shown successful patient acceptance to this clinical procedure. It is of particular advantage to the patient not to be without dentures for the period of at least 1 day necessary for a laboratory-processed relining. Immediate light-curing is time-saving and convenient compared to indirect (heat-cured) relining. Until recently, most direct intraoral applications of autopolymerizing acrylic resin reliner material were considered temporary or expedient to a permanent procedure. The patient and dentist may now have another treatment choice. The release of residual methyl methacrylate, among other shortcomings of AP materials, is not a concern when using the VLC reliner material. Some patients may notice a nonobjectionable taste to the uncured material; however, they can be reassured that the taste will be only temporary until the material is completely polymerized in the curing unit. The flow of the material can be regulated by selection of appropriate viscosity, warming and cooling measures, and partial intraoral polymerization with hand-held curing lights.(ABSTRACT TRUNCATED AT 400 WORDS)

Acrylic Resins↗

Microbicidal efficacy of ozonated water against Candida albicans adhering to acrylic denture plates.

BACKGROUND/AIMS: Ozone is known to act as a strong antimicrobial agent against bacteria, fungi, and viruses. We examined the effect of ozonated water on Candida albicans on acrylic denture plate. METHODS: The heat-cured acrylic resins were cultured with C. albicans. After treatment of flowing ozonated water, the number of attached C. albicans was counted. In some experiments, the test samples were treated with ozonated water in combination with ultrasonication. RESULTS: After exposure to flowing ozonated water (2 or 4 mg/l) for 1 min, viable C. albicans cells were nearly nonexistent. The combination of ozonated water and ultrasonication had a strong effect on the viability of C. albicans adhering to the acrylic resin plates. There were no significant differences in antimicrobial activity against C. albicans between plates immersed in ozonated water with ultrasonication and those treated with commercially available denture cleaners. In addition, electron microscopic analysis revealed that small amounts of C. albicans remained on the plate after exposure to flowing ozonated water or immersion in ozonated water with ultrasonication. CONCLUSION: Our results suggest that application of ozonated water may be useful in reducing the number of C. albicans on denture plates.

Acrylic Resins↗

The bonding properties of elastomer tray adhesives.

1. The surface yielded by the acrylic resin formed against tinfoil provided better retention for the rubber base than any other surface tested. 2. Wax consistently gave the worst results in spite of careful boiling out. 3. The use of wax or asbestos spacers would not degrade the resin surface if tinfoil, or presumably the more easily obtainable aluminum foil, were used as a separating medium. 4. For drying times of between 15 minutes and 72 hours, no significant change was found in bond strength of elastomer to tray material. 5. Drying times of less than 15 minutes were found to be inadequate and to decrease bond strength; they are clinically inadvisable. 6. If, as a result of unavoidable delay, a tray is painted and then left for a number of days prior to making the impression, satisfactory bonding will still occur. However, if the dentist wishes to apply a second coat and dry it for 15 minutes, an increase in bond strength is likely to occur. 7. In the six systems tested, failure occurred at varied levels, from a low of 20 p.s.i. to a high of 80 p.s.i. 8. In the silicone and polyether systems, cohesive failure of the elastomer occurred before the adhesive bond between elastomer and tray failed. This finding correlates with the clinical observation that silicones and polyethers are more difficult to remove completely from acrylic resin trays when an impression has to be repeated.

Acrylic Resins↗

Adherence of Candida albicans to experimental denture soft lining materials.

STATEMENT OF PROBLEM: Colonization of denture soft lining materials by Candida albicans can result in clinical problems. Two experimental silicone soft lining materials have been developed and demonstrate good physical properties. PURPOSE OF STUDY: The aim of this study was to determine the extent of candidal adherence to these materials compared with a commercially available soft lining material and an acrylic resin denture base. MATERIAL AND METHODS: The experimental materials were constructed in a stainless-steel mold, and their surface energies were determined with a dynamic contact angle analyzer. The adherence of three strains of C. albicans was determined with an in vitro assay. In addition, one test strain was used to determine the effect on adherence of precoating the materials with whole saliva. RESULTS: Adhesion to all materials was strain variable, with the lowest adherence recorded for the two experimental materials. Decreased adherence was also apparent after precoating the materials with saliva. Correlation between surface energy of the material and the degree of candidal adhesion was seen for one strain, but no correlation was seen for the other two strains. CONCLUSION: Adherence of C. albicans to the two experimental silicone soft lining materials was significantly less than that for an acrylic resin denture base and a commercially available soft lining material.

Acrylic Resins↗

The national survey of adverse reactions to dental materials in the UK: a preliminary study by the UK Adverse Reactions Reporting Project.

OBJECTIVE: Dental treatment involves the use of a wide range of materials. Many of the dental materials or their components pose a potential risk to the patient and member of the dental team. Pre-market biocompatibility testing cannot guarantee absolute safety, making monitoring of materials likely to cause an adverse reaction essential. The prevalence of adverse reactions to dental materials amongst dental patients and staff has not been systematically monitored in the UK. This project aims to develop a systematic approach to the evaluation and monitoring of the extent and severity of adverse reactions to dental materials in the UK. METHOD: Through the distribution of reporting forms to dental surgeries and laboratories in the UK, the ARRP has received 1,075 complete reports relating to adverse reactions seen or experienced by dental staff and patients. RESULTS: The main findings were that different materials cause adverse reactions to different groups of people. The largest proportion of patient related adverse reactions were reported to be due to metals (n = 175). These were mainly amalgam associated oral lichenoid reactions (n = 124). Dental technicians reported acrylic resin as the causal factor of hand dermatitis in 61% (44 out of a total 72) of cases reported. Finally, dental surgery staff reported gloves as causing hand dermatitis in 75% of cases (398 out of a total 531). CONCLUSIONS: Different dental materials affect different person groups depending on their exposure to the material. Dental staff are most at risk from an adverse reaction to latex gloves, whereas most reported reactions for patients were due to metals. For dental technicians the biggest danger of an adverse reaction was from acrylic resins. There is a need to continue to raise the awareness among dental professionals of the existence of the Adverse Reactions Reporting Project so as to overcome problems of under-reporting.

Acrylic Resins↗

Biocompatibility testing of a silicone maxillofacial prosthetic elastomer: soft tissue study in primates.

Little information exists on the biocompatibility of maxillofacial prosthetic materials. Cosmesil material is a purpose-designed facial prosthetic elastomer that has an established clinical profile in humans but results of biocompatibility testing have not been published. Cosmesil, acrylic resin (positive control), black surgical gutta-percha (negative control), and Silastic 382 material (Dow Corning, Midland, Mich.) (reference control) were processed as custom-designed implants. The implants were inserted into five chacma baboons for a 12-week period in intraosseous, subperiosteal, submucosal, and intramuscular sites. The histologic assessment was based on a modified form of the FDI-ISO Technical Report 7405 for subcutaneous implants. An evaluation was made of capsule formation and inflammatory response. The statistical analysis involved a three-way ANOVA and a Tukey-Kramer Student range test. The critical level of statistical significance chosen was p less than 0.05. The study found that gutta-percha provoked a statistically significantly thicker capsule and a severe inflammatory response. Acrylic resin, Cosmesil material, and Silastic 382 material produced capsule formations and an inflammatory response that did not differ significantly. Cosmesil material is not manufactured as an implant material, but from the present findings it is considered acceptably biocompatible for its intended use where there may be contact with internal tissue spaces that are contiguous to external surfaces.

Acrylic Resins↗

Effects of monomeric acrylic embedding media on the antigenicity of two epitopes of the MIC2-encoded Ewing's sarcoma cell membrane antigen.

Comparative electron microscopic studies of pre- and postembedding immunolabeling experiments have shown that the antigenicity of some epitopes is lost during acrylic resin embedding of the respective tissues. In the present investigation we have tested the sensitivities of two embedding-labile epitopes (HBA-71 and HBA-45) of the Ewing's sarcoma-associated MIC2-encoded E2 antigen to the effects of the different treatment steps, which are necessary for the preparation of ultrathin sections. The extent of antigenic retention was quantitated using flow cytometry and enzyme-linked immunosorbent assays (ELISA) of tumor cell lines, thymocytes and cell membrane extracts. Fixation, dehydration and high temperature treatment of MIC2-positive cells showed only minor effects on the reactivity with the HBA-71 and HBA-45 antibodies. However, exposure of the cells to the monomeric acrylic resins LR White (LRW), LR Gold (LRG) and Lowicryl K4M at 4 degrees C for 2-18 h resulted in a significant reduction of the HBA-71 and HBA-45 reactivities. In contrast, the antigenicity of both epitopes was maintained during treatment with the apolar Lowicryl HM20 embedding medium under these non-polymerizing conditions. The resins have no direct effect on the HBA-71/HBA-45 antigen, since it could be extracted in intact form from membranes of native, but not of fixed, tumour cells using LRW for membrane solubilization. These data indicate that the HBA-71/HBA-45 antigen remains in the cell membrane and is indirectly influenced by the extraction/modification of adjacent membrane constituents. The adverse effects of the polymerization process, in the case of embedding at low temperature in Lowicryl HM20, destroyed MIC2-antigenicity.(ABSTRACT TRUNCATED AT 250 WORDS)

Acrylic Resins↗

Alternative complete-arch cement-retained implant-supported fixed partial denture.

Early implant prostheses designs, which used screw-retained metal and acrylic resin structures, frequently left a space between the prosthesis and the soft tissue. Common deficiencies of this design included phonetic and esthetic problems and screw loosening. Cement-retained implant prostheses are also used in partially and completely edentulous patients, and are thought to have optimal occlusion and esthetics. Moreover, cement-retained prostheses may induce less stress on the implant, thereby maximizing the possibility of a passive fit. Porcelain fused to metal prostheses have been used mostly in partially edentulous situations. Recently, complete-arch porcelain fused to metal prostheses that replace hard and soft tissue have been used and, although this restoration can have excellent esthetics, there are disadvantages such as high cost, potential framework distortion during fabrication, and difficulty in repairing fractures of in-service porcelain. This article describes an alternative technique for the fabrication of a complete-arch, cement-retained, metal-acrylic resin implant-supported fixed partial denture. When compared with porcelain fused to metal complete-arch restorations, this prostheses is esthetic, has excellent retention and stability, yet is relatively inexpensive to fabricate, and requires less laboratory skill.

Acrylic Resins↗

The effect of acquired salivary pellicle on the surface free energy and wettability of different denture base materials.

OBJECTIVE: The objective of the present study was to evaluate the effect of salivary coating on the wettability and surface free energy of different denture base materials. METHODS: Five acrylic resin and two metallic denture base materials were investigated. Ten specimens of each material (20 x 15x1.5mm) were fabricated and a standardized method was used for polishing the test specimens. Whole unstimulated saliva was collected from a single healthy donor. The wettability properties of the materials were tested before and after organic layer formation. The wetting forces were determined according to the Wilhelmy Plate Technique. Diiodomethane, ethylene glycol and formamide were used as probe liquids. The contact angles, Lifshitz-van der Waals surface energy components, Lewis acid-base surface energy components and total surface energies were calculated using the equations described in the paper. The significance of the differences in the experimentally determined surface energies of different denture materials are calculated by statistical methods. CONCLUSIONS: Light-cured acrylic resin was the most wettable material with a significant basic character. Organic layers decreased the total surface free energies of all materials and at the same time imparted a more basic character. The coatings had a homogenizing effect in terms of the surface free energy components of the denture materials, nevertheless, their adhesive properties were still influenced by the substrate employed.

Acrylic Resins↗

The oral pigmentation chart: a clinical adjunct for oral pigmentation in removable prostheses.

PURPOSE: Non-Caucasian patients exhibit different characteristics of oral pigmentation and may request that the acrylic resin parts of their dentures look natural, simulating the original mucosal color. Tooth loss, bone resorption, and lack of attached gingiva may, however, make it difficult to determine what the original pigmentation was like. The purpose of this investigation was to study the distribution in oral pigmentation around the natural dentition in non-Caucasians, in a preliminary effort to classify these variations into a chart of oral pigmentation, and to analyze its reproducibility. MATERIALS AND METHODS: For the study, 106 dentate non-Caucasians were selected from two universities: ACTA (patient group) and UCLA (nonpatient group). A pigmentation scheme was devised on the basis of half of the participants, and the others were divided into categories by four observers independently. Cohen's kappa was then calculated. RESULTS: On the basis of information obtained from the ACTA participants, six categories of mucosal pigmentation were defined. The kappa statistics for the four observers varied from .58 to .79 for intraobserver agreement and from .15 to .55 for interobserver agreement. CONCLUSION: The Oral Pigmentation Chart is a simple device that makes it possible to simulate oral pigmentation in the acrylic resin parts of removable dentures. The reproducibility appeared to be acceptable when clinician and dental technician were calibrated. Patients can be offered a choice of the kind of pigmentation geography they want in their removable prostheses.

Acrylic Resins↗

Effect of a fluoride varnish on the margin leakage and retention of luted provisional crowns.

STATEMENT OF PROBLEM: Provisional crowns cemented with provisional luting agents are susceptible to washout, margin leakage, and secondary caries when placed for a prolonged period. PURPOSE: This study was conducted to determine the effect of combining a varnish containing 2.26% NaF with 2 provisional luting agents on the margin leakage and retention of provisional crowns. MATERIAL AND METHODS: Acrylic resin provisional crowns were fabricated for 8 shoulder-prepared molars. The eight provisional (N=24) crowns were luted individually with Temp-Bond (TB), Freegenol (FG), or Duraphat (DU). Specimens were thermocycled 500 times (5 degrees and 60 degrees C) with a 1-minute dwell time, stored in 100% relative humidity at 37 degrees C for 6 days, and then immersed in a 0.5% Gentian violet solution for 24 hours. Seven days after cementation, a removal test of the crowns (shear retention test) was conducted with a universal testing machine at a crosshead speed of 5 mm/min. Retention was determined as the maximum recorded force needed for crown dislodgment. DU varnish was applied to the inner surface of the dislodged crowns with no removal of the cement layer TB, FG (N=16). The crowns were relined with a 0.5-mm layer of acrylic resin and luted with a combination of luting agent and DU (TB, FG) N=16. No luting agent (NC) served as the control (N=8). Results were analyzed with the Wilcoxon matched-pairs signed-ranks test. Leakage at the margins was assessed with a 4-level dye penetration scale, and statistical differences were identified with a chi(2) test. All hypothesis testing was conducted at the 95% level of confidence. RESULTS: The mean 7-day retention forces were as follows: 44.5 N (Temp-Bond), 51.6 N (Freegenol), and 35.9 N (Duraphat). There were no significant differences among these values. Duraphat combined with Freegenol decreased the retention of provisional crowns, but Duraphat combined with Temp-Bond increased the retention of provisional crowns by 69-145%. Duraphat alone and in combination with both provisional luting agents significantly reduced margin leakage (P<.05). The least margin leakage was evident when the provisional crowns were luted with Duraphat alone. CONCLUSION: With regard to retention and margin leakage, the results of this study suggest that Duraphat varnish can be successfully used as provisional luting agent for single provisional crowns.

Acrylic Resins↗

Denture labels affixed with light-cured versus self-cured resin.

The use of a light-cured acrylic resin was compared to self-cured resin for sealing personal identification labels in existing removable dental prostheses. The light-cured material rated better consistently than the self-cured resin in lack of stain or yellowing, legibility of print, lack of porosity, marginal seal, and surface finish. Another valuable feature of this system was the reduced time required for completion of the procedure.

Acrylic Resins↗

[Thermal expansion of restorative composite resins under the dry and wet conditions (author's transl)].

Linear coefficients of thermal expansion (beta) of twelve restorative composite resins, one Bis-GMA based resin and one self-curing acrylic resin were determined in the temperature range of 4 to 60 degrees C under the dry and the wet conditions on a thermomechanical analyzer. The results were as follows. 1) The thermal expansion curves obtained were nonlinear, and the transition appeared at about 40 degrees C. 2) beta reduced with the elapse of stored time and the number of times of measuring run. It appears that these phenomena were attributable to decrease of monomer remained in each case. 3) beta under the wet condition was larger than one under the dry condition, when specimens were stored for 20 days in each condition at 37 degrees C. Values of beta for composites ranged from 16.1 to 35.3 x 10(-6)/degrees C under the dry condition and from 18.1 to 55.4 x 10(-6)/degrees C under the wet condition. 4) beta of composites varied with filler content and kinds of filler and resin used. Value of beta reduced with increase of filler content, and was lower for Bis-GMA based composite resin than for MMA based composite resin.

Acrylic Resins↗

[The technic for the reoptimization of laryngeal cannulae by recoating them with a silicone material].

In the laryngeal surgical pathology area, the application of a cannula with temporary or long term indications is necessary for ensuring the respiratory function troubled by various causes (inflammatory, tumor or traumatic) that obstruction the respiratory tract. The most frequently used standard cannula is rigid and does not show proper adaptation for every clinical situation, thus leading to local troubles. In this paper, the realization technique of a rigid/flexible and individual cannula applied after the tracheotomy is presented. In order to carry out the cannula, a rigid material is utilized (acrylic resin) for maintaining the shape and dimensions of the laryngeal stoma. It is also utilized an elastically material (acrylic resin with a retard plug--Simpa) that ensures the optimal adaptation, tight close and tissue protection around the stoma. In co-operation with the ORL Clinic--Recuperation Hospital, these cannulae were applied to fifteen patients pursuing their evolution in time.

Catheterization↗