Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLATES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71Linked to original sources

Preparation, characterization and controlled release investigation of interpenetrating polymer networks of poly(acrylic acid)/triazole modified poly(vinyl alcohol).

A series of interpenetrating polymer networks of poly(acrylic acid) (PAA)/triazole modified poly(vinyl alcohol) (TMIPNs) were synthesized by radical polymerization in methanol at room temperature with l-ascorbic acid (Vc) and peroxide hydrogen (H2O2) as initiators and trihydroxymethyl propane glycidol ether (6360) as a crosslinker. The structures of the gels were characterized by Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC). The swelling/deswelling behavior of hydrogels was studied in different pH and different concentrations of NaCl aqueous solutions. The results showed that the TMIPNs hydrogels had excellent pH- and salt-sensitivity in the range of the investigation. The mechanism of the swelling and the deswelling was discussed and the results were confirmed further by scanning electron microscope (SEM). In addition, the controlled release behavior of TMIPNs in vitro was also studied. The effects of physical stimulus (ultraviolet ray and ultrasonic wave), salt concentration, pH value and the swelling/deswelling on the controlled released behavior were also explored.

Acrylic Resins↗

Cataract extraction and primary hydrophobic acrylic intraocular lens implantation in infants.

PURPOSE: We sought to report the incidence of visual axis opacification and to evaluate the complication and reoperation rates after intraocular lens implantation in infants. METHODS: Twenty-one infants (31 eyes) who had cataract extraction with primary hydrophobic acrylic IOL implantation between October 1996 and May 2002 were reviewed. Posterior capsule was left intact in 14 eyes (group A); posterior capsulorrhexis or capsulotomy with anterior vitrectomy was performed in 17 eyes (group B). Complication and reoperation rates were compared with an age-matched control group of 17 patients (33 eyes) who were left aphakic after pars plicata lensectomy. Mean follow-up period was 41 months (range, 22-75 months) in group A, 37 months (range, 10-75 months) in group B, and 52 months (range, 7-97 months) in the control group. RESULTS: Mean age of the patients was 6.8 months (range, 3-10 months) in group A, 8.9 months (range, 3-18 months) in group B, and 4.9 months (range, 1-15 months) in the control group. Visual axis opacification was significantly higher in group A (86%) when compared with group B (17.6%; P < 0.0001). No significant difference was found in terms of pupillary irregularities and peripheral anterior synechiae formation between pseudophakic and aphakic group ( P = 0.43 and P = 0.306, respectively), whereas pigment dispersion and fibrinous reaction were significantly more common in the pseudophakic group ( P = 0.002). Serious complications, such as retinal detachment, pseudophakic bullous keratopathy, and secondary glaucoma, did not develop in any eye. Reoperation rate was significantly higher in group A (78%) when compared with group B (17%) and the control group (12%; P = 0.0011 and P < 0.0001, respectively). CONCLUSIONS: Visual axis opacification requiring a reoperation was significantly more common in patients with an intact posterior capsule. To decrease the reoperation rate and maintain a clear visual axis, posterior capsulorrhexis with anterior vitrectomy should be performed. Even although early complications were quite frequent, serious late complications were not encountered in any eye. Therefore, under appropriate conditions, IOL implantation is a suitable alternative in infants.

Acrylates↗

Hydrolase-catalyzed Michael addition of imidazoles to acrylic monomers in organic medium.

Hydrolase-catalyzed Michael addition of imidazole derivatives to acrylic monomers in organic medium was described. A serial of N-substituted imidazole derivatives were successfully synthesized in moderate yields by the catalysis of hydrolases in organic medium. Nine commercially available hydrolases from different sources were screened and all of them were found to be able to catalyze this type of addition reaction. The reaction yields depended on the solvent properties and the solvents with higher log P value supported this enzyme-catalyzed reaction to give higher conversion. Influence of the structure of the Michael acceptor and donor on the enzymatic Michael addition was also investigated. The acceptor with shorter alcohol chain afforded a higher yield. A more rapid conversion was observed when the donor had an electron-withdrawing group. This hydrolase-catalyzed Michael addition reaction has widened the applicability of biocatalysts in organic and bioorganic synthesis.

Acrylates↗

Determination of total tiopronin in human plasma by LC-ESI-MS using tris (2-carboxy-ethyl) phosphine as reducing reagent and methyl acrylate as derivatization reagent for the thiol group.

A quantitative method for the determination of total tiopronin (TP) in human plasma was developed by liquid chromatography with electrospray ionisation (ESI) mass spectrometric detection. After reduction with tris (2-carboxy-ethyl) phosphine (TCEP) and derivatization with methyl acrylate (MA) for the thiol group of TP, plasma samples were processed successively by deproteinization and solid phase extraction. N-acetyl-l-cysteine (NAC) was selected as internal standard undergoing the same treatment as TP. The method was validated that it could meet the need of biological analysis. The lower limit of quantitation (LLOQ) of TP in plasma was 0.02microg/mL. Finally, the method was successfully applied to a pharmacokinetic study in 20 healthy Chinese male volunteers after an oral dose of 200mg TP tablets.

Acrylates↗

Experimental study of albumin and lysozyme adsorption onto acrylic acid (AA) and 2-hydroxyethyl methacrylate (HEMA) surfaces.

Many commercial soft contact lenses are based on poly-2-hydroxyethyl methacrylate (HEMA) and acrylic acid (AA) hydrogels. The adsorption of proteins, albumin and lysozyme, on such contact lens surfaces may cause problems in their applications. In this work the adsorption of proteins, albumin and lysozyme, on hydrogel surfaces, AA and HEMA, was investigated as a function of concentration of protein. Also the effects of pH and ionic strength of protein solution on the adsorption of protein were examined. The obtained results indicated that the degree of adsorption of protein increased with the concentration of protein, and the adsorption of albumin on HEMA surface at the studied pHs (6.2-8.6) was higher than AA surface, whereas the adsorption of lysozyme on AA surface at the same pHs was higher than HEMA. The change in ionic strength of protein solution affected the proteins adsorption on both AA and HEMA surfaces. Also, the amount of sodium ions deposited on the AA surface was much higher than HEMA surface. This effect can be related to the negative surface charge of AA and its higher tendency for adsorption of sodium ions compared to the HEMA surface.

Acrylates↗

Enzyme immobilization on poly(ethylene-co-acrylic acid) films studied by quartz crystal microbalance with dissipation monitoring.

In this study, we use the quartz crystal microbalance with dissipation monitoring (QCM-D) to study the immobilization of the enzyme horseradish peroxidase (HRP) on poly(ethylene-co-acrylic acid) (PEAA) films. The surface polarity of spin-coated PEAA films was varied by heat treatments in air or in a 30% NaOH aqueous solution leading to COOH-depleted or COOH-enriched surfaces, respectively. Two reaction schemes, direct adsorption and amine coupling, were employed for HRP immobilization on the two surfaces. The shifts in frequency and dissipation, Deltaf and DeltaD, measured by QCM-D and the ratio DeltaD/Deltaf were used to evaluate the binding amount and the conformation of the adsorbed enzyme. It is found that HRP immobilized via covalent linkages forms rigid and little dissipative films. In contrast, directly adsorbed HRP films exhibit a highly dissipative structure. HRP-catalyzed oxidation of the 4-chloro-1-naphthol in the presence of H(2)O(2) was used to characterize the catalytic activity of the HRP films. The results show that the enzymatic activity of the covalently immobilized HRP tends to be higher.

Acrylic Resins↗

Preparation of anion exchanger by amination of acrylic acid grafted polypropylene nonwoven fiber and its ion-exchange property.

To develop the polymeric adsorbent that possess anionic exchangeable function, PP-g-AA-Am fibers were prepared by photoinduced grafting of acrylic acid (AA) onto polypropylene (PP) nonwoven fibers and subsequent conversion of carboxyl group in grafted AA to an amine (Am) group by reaction with diethylene triamine (DETA). The amination of grafted AA increased with increase in the degree of grafting, the reaction time and temperature of the chemical modification process. Catalytic effect of metal chlorides such as AlCl(3) and FeCl(3) on the amination of grafted AA was significant but not essential to lead the amination. FT-IR and solid (13)C NMR data indicate that amine group was introduced into PP-g-AA fiber through amide linkage between grafted AA and DETA. The anion exchange capacity of PP-g-AA-Am fiber increased with increase in the degree of amination, but reached maximum value at about 60% amination of 150% grafted AA. PP-g-AA-Am fiber showed much higher maximum capacity for PO(4)-P and a similar capacity for NO(3)-N compared to commercial anion resins. Furthermore, the PP-g-AA-Am fiber also has adsorption ability for cations because of unaminated residual carboxyl group.

Absorption↗

Poly(vinyl alcohol) and poly(acrylic acid) sequential interpenetrating network pH-sensitive microspheres for the delivery of diclofenac sodium to the intestine.

Sequential interpenetrating network (IPN) of poly(vinyl alcohol) (PVA) and poly(acrylic acid) (PAA) were prepared and crosslinked with glutaraldehyde (GA) to form pH-sensitive microspheres by the water-in-oil (w/o) emulsification method. Microspheres were used to deliver a model anti-inflammatory drug, diclofenac sodium (DS), to the intestine. The formed IPN was analyzed by Fourier transform infrared spectroscopy (FTIR). Differential scanning calorimetry (DSC) and X-ray diffraction (XRD) analyses were done on the drug-loaded microspheres to confirm the polymorphism of DS. Results indicated a molecular level dispersion of DS in the IPN. Microspheres formed were spherical with the smooth surfaces as evidenced by scanning electron microscopy (SEM). Particle size and size distribution was studied using laser light diffraction particle size analyzer. Particle size analysis was also done by optical microscope for the selected microspheres; the change in diameter of the microspheres when soaked in different media at different time intervals was measured by optical microscope. Microspheres showed a pulsatile swelling behavior when the pH of the swelling media was changed. The swelling data were fitted to an empirical equation to understand the phenomenon of water transport as well as to calculate the diffusion coefficient (D). Values of D in acidic media were lower than those found in basic media. The values of D decrease with increasing crosslinking of the matrix. In-vitro release studies have been performed in 1.2 and 7.4 pH media to simulate gastric and intestinal conditions. The results indicated a dependence on the pH of the release media, extent of crosslinking and the amount of drug loading.

Acrylic Resins↗

Solubilization and stabilization of camptothecin in micellar solutions of pluronic-g-poly(acrylic acid) copolymers.

The capability of a family of copolymers comprising Pluronic (PEO-PPO-PEO) surfactants covalently conjugated with poly(acrylic acid) (Pluronic-PAA) to enhance the aqueous solubility and stability of the lactone form of camptothecin (CPT) was studied. The unprotected lactone form of CPT, which possesses cytotoxic activity, is rapidly converted to the ring-opened carboxylate form under physiological conditions. Firstly, surfactant properties such as critical micellization concentration (CMC) of Pluronic-PAA copolymers were characterized. Then, the equilibrium solubility partitioning and hydrolysis of the lactone form of CPT in the presence of Pluronic-PAA in water and in human serum were analyzed. CPT solubility in polymer micellar solutions was ca. 3- to 4-fold higher than that in water at pH 5. The amount of CPT solubilized per PPO was considerably greater in the Pluronic-PAA solutions than in the parent Pluronic solution, which suggests that the drug is not only solubilized by the hydrophobic cores and also by the hydrophilic POE-PAA shells of the micelles. The equilibrium partition coefficient of the CPT lactone between Pluronic-PAA solutions and water exceeded (2-3) x 10(3). The complete solubilization of CPT and the absence of chemical interactions between CPT and Pluronic-PAA were confirmed by modulated temperature differential scanning calorimetry (MTDSC), infrared spectroscopy, and X-ray diffraction of films. The loading of CPT into the Pluronic-PAA micelles was able to prevent the hydrolysis of the lactone group of the drug for 2 h at pH 8 in water. When compared to the unprotected CPT, the kinetics of the CPT hydrolysis in human serum was about 10-fold slower in the Pluronic-PAA formulations.

Acrylic Resins↗

Management of a posteriorly dislocated endocapsular tension ring and a foldable acrylic intraocular lens.

We report a rare case of late spontaneous extension of a posterior capsule tear from lateral traction of an endocapsular ring, resulting in dislocation of the capsular tension ring and acrylic intraocular lens (IOL) into the vitreous cavity. A 3-port pars plana vitrectomy was performed to explant the prostheses; the eye was made pseudophakic by placement of a scleral-fixated posterior chamber IOL. The combined triple procedure was safe and effective.

Acrylic Resins↗

Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge.

PURPOSE: To evaluate the development of posterior capsule opacification (PCO) after implantation of single-piece hydrophilic acrylic intraocular lenses (IOLs) with an enhanced square edge. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: The standard 570H Centerflex (Rayner Ltd.) design was compared to 2 new designs with enhanced square edges: the 570E and the 570C. Ten IOLs of each type were implanted in a randomized manner by the same surgeon in 15 pigmented rabbits. After a follow-up of 3 weeks, the rabbits were killed and the eyes were analyzed from the posterior view. The intensity of central PCO, peripheral PCO, and Soemmering's ring formation was graded from 0 to 4. The area of Soemmering's ring was graded from 0 to 4 based on the number of quadrants involved. Other parameters analyzed were capsulorhexis coverage of the IOL edge and IOL centration and fixation. Results from the posterior view were complemented by histopathological evaluation. RESULTS: Posterior capsule opacification was lowest in the 570C group, highest in the 570H group, and intermediate in the 570E group. There was a statistically significant difference between the 3 groups in peripheral PCO (P = .039). No significant difference was found between the groups in the other parameters analyzed. When cell ingrowth occurred with the 570H, it started at the optic-haptic junctions, as observed during the clinical follow-up and confirmed by gross and histopathological analyses. CONCLUSIONS: The square optic edge is the most important IOL design feature for PCO prevention. However, it should be present for 360 degrees around the IOL optic to provide an effective barrier effect.

Acrylic Resins↗

Posterior capsule opacification in rabbit eyes implanted with 1-piece and 3-piece hydrophobic acrylic intraocular lenses.

PURPOSE: To evaluate the outcome of posterior capsule opacification (PCO) after implantation in rabbit eyes of currently available 3-piece and 1-piece hydrophobic acrylic intraocular lenses (IOLs) with square optic edges. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: The 3-piece designs evaluated were the AR40e (Advanced Medical Optics Inc.) and the MA60AC (Alcon, Inc.); the 1-piece designs were the SA60AT and the SA30AT (Alcon, Inc.). Nine lenses of each type were implanted in a randomized manner by the same surgeon in 18 Dutch Belted pigmented rabbits. After a follow-up of 3 weeks, the rabbits were killed and analyses of the enucleated eyes were performed from the posterior or Miyake-Apple view. The intensity of central PCO, peripheral PCO, and Soemmering's ring formation was scored from 0 to 4. The area of Soemmering's ring formation was also scored from 0 to 4 based on the number of quadrants involved. Other parameters analyzed were capsulorhexis coverage of the IOL anterior surface, IOL centration, fixation, and presence of striae. Results from the posterior view were complemented by histopathologic evaluation of the eyes. RESULTS: No statistically significant difference was found between the 4 groups of IOLs in the parameters analyzed from the posterior view. When cell ingrowth occurred with the 1-piece designs, causing peripheral and central PCO formation, it was more likely to start at the optic-haptic junctions, as observed during the clinical follow-up with slitlamp examination and confirmed by gross and histopathologic analyses of the enucleated eyes. CONCLUSIONS: The square, truncated optic edge is the most important IOL design feature for PCO prevention. The optic-haptic junctions of the 1-piece designs appear to be sites where the barrier effect of the truncated optic edge is less effective.

Acrylic Resins↗

Effect of tilt of 2 acrylic intraocular lenses on high-order aberrations.

PURPOSE: To investigate the high-order aberrations (HoAs) in pseudophakia between 2 foldable acrylic intraocular lenses (IOL) with differences in the tilt of IOL. SETTING: Department of Ophthalmology, Nara Medical University, Nara, Japan. METHOD: Sixty-four eyes that had uncomplicated phacoemulsification and IOL implantation were assigned to 1 of 2 groups: Acryfold 60BB (HOYA [n=30 eyes]) and AcrySof MA60AC (Alcon [n=34 eyes]). All patients had best corrected visual acuity better than 20/25. High-order aberrations were measured using the Hartmann-Shack aberrometer at 4.0 mm and 6.0 mm wavefront aperture diameters, and the IOL tilt and decentration were measured using Scheimpflug videophotography. RESULTS: There was a significant difference in the IOL tilt (60BB=2.22 degrees +/- 1.44 (SD), 60AC=3.18 +/- 1.84 degrees; P=.041, Mann-Whitney U test), but no difference in IOL decentration (P>.05). In the cornea, there were no differences between the 2 groups in HoAs at 4.0 mm and 6.0 mm aperture diameters (P>.05, Mann-Whitney U test). In the whole eye, there was no difference between the 2 groups in spherical-like aberrations, coma-like aberrations, and total aberrations at the 4.0 mm and 6.0 mm aperture diameters (P>.05). The compensation of the internal optics with the 60BB group was better than with the 60AC group for coma-like (P=.037) and total aberrations (P=.010) at 6.0 mm aperture diameter. CONCLUSION: The smaller tilt of the IOL induced more compensation for the coma-like and total aberrations at the 6.0 mm aperture diameter. The IOL tilt should be small, especially in a large pupil, with regard to HoAs.

Aberrometry↗

Two opacification patterns of the same hydrophilic acrylic polymer: case reports and clinicopathological correlation.

We report 2 intraocular lenses (IOLs) manufactured from the same hydrophilic acrylic polymer by Ioltech that developed optic opacification. In both cases, the postoperative course after implantation of the IOLs was complicated by significant inflammatory reaction with fibrin formation in the anterior chamber. Pathologic analyses of the explanted IOLs were consistent with dystrophic calcification leading to optic opacification, but the pattern was different between the 2 IOL designs. Patient-related factors might have been responsible for this complication.

Acrylic Resins↗

Suppression of fibroblast and bacterial adhesion by MPC coating on acrylic intraocular lenses.

PURPOSE: To investigate cell adhesion to intraocular lens (IOL) surfaces having different properties using bacteria and fibroblasts. SETTING: Department of Ophthalmology, Tokyo Medical University Hospital, Tokyo, Japan. METHODS: The polished acrylic IOLs VA60-BB and VA-60-CB (Hoya) were used with no coating or after coating with poly(2-methacryloyloxyethyl phosphocholine-co-n-butyl-methacrylate) (MPC) or methane gas plasma. Each IOL was placed in a culture of Staphylococcus aureus (5 x 10(7) colony forming units [CFU]/mL) or fibroblasts (SUSM-1, 1 x 10(4) cells/mL), and the cells adhering to the IOL surface were counted after the culture. Fibroblast adhesiveness was evaluated by centrifuging post-culture IOLs in test tubes at up to 15,000 rpm and looking at the ICAM-1 mRNA expression in the adhering fibroblasts using real-time polymerase chain reaction. RESULTS: After 1 minute in the bacterial culture, the mean adhering bacteria count was 0.7 x 10(6) CFU in the MPC-coated IOL group and about 2.0 x 106 CFU in the noncoated IOL group (P = 0.03) and the plasma-coated IOL group (P = 0.02). After 96 hours in the fibroblast culture, the adhering fibroblast count was 2.2/mm2 in the MPC-coated IOL group, significantly lower (P = 0.009) than 57.6/mm2 in the noncoated IOL group and 125.8/mm2 in the plasma-coated IOL group. Cell adhesion and ICAM-1 mRNA expression were weak on the MPC-coated IOL, intermediate on the noncoated IOL, and relatively strong on the plasma-coated IOL. CONCLUSION: The MPC-coated IOL surface inhibited bacterial and fibroblast adhesion, which is an initial stage of cell proliferation and expression, suggesting that MPC coating may provide an effective means of reducing the risk for endophthalimitis in IOL implantation.

Acrylic Resins↗

Hydrophilic acrylic intraocular lens exchange: Five-year experience.

PURPOSE: To evaluate clinical outcomes of opacified SC60B-0UV intraocular lens (IOL) (MDR, Inc.) and clear SC60B-0UV IOL exchange. SETTING: Department of Ophthalmology, Queen's Hospital, Burton-on-Trent, United Kingdom. METHODS: In a prospective audit, 149 patients with 152 SC60B-0UV hydrophilic acrylic IOLs were monitored over 5 years. Perioperative complications were evaluated. The best spectacle-corrected visual acuity, subjective quality of vision, and VF-14 scores were compared preoperatively and postoperatively. RESULTS: Ninety-eight IOLs developed opacification; 52 IOLs were exchanged between February 1999 and October 2004. The lens exchange procedure was uneventful in 39 eyes (75%). Perioperative complications included zonular dehiscence and posterior capsule rupture in 12 eyes (23.1%), total capsule-IOL extraction in 4 eyes (7.7%), iridodialysis in 3 eyes (5.8%), hyphema in 2 eyes (3.8%), and retained haptics in 5 eyes (9.6%). The mean logMAR visual acuity and mean VF-14 scores improved significantly after IOL exchange (P < .01). Forty-seven patients (90.4%) reported improvement in the subjective quality of vision after IOL exchange. However, after the exchange, visual acuity worsened in 5 patients (9.6%) and subjective quality of vision worsened in 3 patients (5.8%); the VF-14 scores decreased in 5 (14.7%) of the 34 patients tested. CONCLUSIONS: Visual function and quality of life were better after IOL exchange. However, poor outcomes in some patients mandate an extensive informed consent procedure for clear IOL exchange.

Acrylic Resins↗

Effect of relining, water storage and cyclic loading on the flexural strength of a denture base acrylic resin.

OBJECTIVES: This study investigated the effect of relining, water storage and cyclic loading on the ultimate flexural strength (FS(U)) and on the flexural strength at the proportional limit (FS(Pl)) of a denture base acrylic resin (Lucitone 550-L). METHODS: Rectangular bars of L were made (64 mm x 10 mm x 2 mm) and relined (1.3mm) with four relining resins (Kooliner-K, Ufi Gel Hard-UGH, Tokuso Rebase Fast-TR and New Truliner-NT). In addition, specimens relined with L and intact L specimens were made (64 mm x 10 mm x 3.3 mm). A three-point flexural test was applied on the specimens (n=10) after (1) polymerization; (2) water storage (30 days); (3) cyclic loading (10,000 cycles at 5 Hz) and (4) water storage (30 days)+cyclic loading. Data (MPa) were analyzed with three-way ANOVA and Tukey's HSD tests (alpha=0.05). To test for a possible correlation between FS(U) and FS(Pl), a linear regression coefficient "r" was calculated. RESULTS: After water storage, L-UGH and L-TR demonstrated an increased FS(U) (41.49-50.64 MPa and 49.95-57.36 MPa, respectively) (P<0.05). Only L-TR demonstrated an increased FS(Pl) (20.58-24.21 MPa) after water storage (P<0.05). L-L had the highest FS(U) (between 78.57 and 85.09 MPa) and FS(Pl) (between 31.30 and 34.17 MPa) (P<0.05). The cyclic loading decreased the FS(U) and FS(Pl) of all materials (P<0.05). Regression analysis showed a strong linear correlation between the two variables (r=0.941). CONCLUSIONS: Water storage improved the FS(U) of L-UGH and L-TR and the FS(Pl) of L-TR. L-L produced the highest FS(U) and FS(Pl). The FS(U) and FS(Pl) of all materials were detrimentally influenced by cyclic loading.

Acrylic Resins↗

Late postoperative opacification of a hydrophilic acrylic (hydrogel) intraocular lens: a clinicopathological analysis of 106 explants.

PURPOSE: To report clinical, pathologic, histochemical, ultrastructural, and spectroscopic analyses of MemoryLens intraocular lenses (IOLs) explanted from patients who had visual disturbances caused by postoperative opacification of the lens optic. DESIGN: Noncomparative, large case series with clinicopathologic correlation. PARTICIPANTS: A total of 106 hydrophilic acrylic IOLs of the same design explanted from 106 different patients. All patients had decreased visual acuity at presentation approximately 2 years after cataract surgery, associated with a whitish fine granularity on the optical surfaces of the IOLs. METHODS: The explanted IOLs were submitted to the John A. Moran Eye Center and were examined under light microscopy, histochemically, and with scanning electron microscopy (SEM) equipped with an energy dispersive x-ray spectroscopy detector with light element capabilities (EDS). MAIN OUTCOME MEASURES: The IOLs were examined for distribution, structure, and composition of the deposits causing opacification of their optic components. RESULTS: The average interval between lens implantation and opacification was 25.8+/-11.9 months. The most frequently associated medical and ophthalmic conditions were diabetes and glaucoma. However, some patients did not have any preexisting medical or ophthalmic conditions. Most of the IOLs had been implanted in 1999 and 2000. Microscopic analyses revealed the presence of multiple fine, granular deposits of variable sizes on the anterior and posterior optic surfaces, especially on the anterior surface. The deposits stained positive for calcium. The EDS confirmed the presence of calcium and phosphate within the deposits. CONCLUSIONS: The results obtained suggest the surface deposits to be composed, at least in part, by calcium and phosphate. A special polishing technique used in the manufacture of most of these IOLs may have caused changes in the lens surface leading to deposit formation. Further studies should be undertaken to confirm this hypothesis.

Acrylic Resins↗