Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “sample preparation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

Determination of perfluorodecalin and perfluoro-N-methylcyclohexylpiperidine in rat blood by gas chromatography-mass spectrometry.

A gas chromatography-mass spectrometry method (SIM mode) was developed for the determination of perfluorodecalin (cis and trans isomers, 50% each) (FDC), and perfluoromethylcyclohexylpiperidine (3 isomers) (FMCP) in rat blood. The chromatographic separation was performed by injection in the split mode using a CP-select 624 CB capillary column. Analysis was performed by electronic impact ionization. The ions m/z 293 and m/z 181 were selected to quantify FDC and FMCP due to their abundance and to their specificity, respectively. The ion m/z 295 was selected to monitor internal standard. Before extraction, blood samples were stored at -30 degrees C for at least 24 h in order to break the emulsion. The sample preparation procedure involved sample clean-up by liquid-liquid extraction. The bis(F-butyl)ethene was used as the internal standard. For each perfluorochemical compound multiple peaks were observed. The observed retention times were 1.78 and 1.87 min for FDC, and 2.28, 2.34, 2.48 and 2.56 min for FMCP. For each compound, two calibration curves were used; assays showed good linearity in the range 0.0195-0.78 and 0.78-7.8 mg/ml for FDC, and 0.00975-0.39 and 0.39-3.9 mg/ml for FMCP. Recoveries were 90 and 82% for the two compounds, respectively with a coefficient of variation <8%. Precision ranged from 0.07 to 15.6%, and accuracy was between 89.5 and 111.4%. The limits of quantification were 13 and 9 microg/ml for FDC and FMCP, respectively. This method has been used to determine the pharmacokinetic profile of these two perfluorochemical compounds in blood following administration of 1.3 g of FDC and 0.65 g of FMCP per kg body weight, in emulsion form, in rat.

Animals↗

Direct assay for creatine kinase by reversed-phase high-performance liquid chromatography.

A direct assay for creatine kinase (CK) activity was developed based on the separation and quantitation of adenosine triphosphate (ATP) by high-performance liquid chromatography. The total incubation time is 13 min and the elution time for ATP is 16 min. Using lyophilized CK as the sample, a sensitivity in the range of 8 U/l (units/liter) was obtained. The method presented also has clinical significance in that CK levels in serum can easily be determined with minimal sample preparation. Using serum samples from a healthy patient and a heart attack victim, activities of 26.6 U/l and 609.0 U/l, respectively, were obtained. Because of the direct measurement of ATP, this method eliminates the coupled reactions encountered in the common spectrophotometric and colorimetric methods of analysis resulting in a simpler and inexpensive assay.

Adenosine Triphosphate↗

Simple high-performance liquid chromatographic method for the measurement of amiloride in body fluids.

A simplified rapid high-performance liquid chromatographic (HPLC) procedure has been developed for the measurement of amiloride in plasma or urine. Solid-phase extraction columns provide quick, clean and simple sample preparation, allowing ten samples to be processed in less than 5 min. The HPLC system uses a standard reversed-phase (C18) column with detection by ultraviolet absorption at 365 nm. The assay has been used to define plasma amiloride concentration-time profiles and to quantitate urine amiloride recovery in healthy men after repeated administration at two doses.

Adult↗

Capillary electrophoretic drug monitoring of methotrexate and leucovorin and their metabolites.

High-dose methotrexate is an important element of treatment protocols in childhood acute lymphocytic leukemia or osteosarcoma. A capillary electrophoretic method has been developed to measure peak levels and the metabolite pattern in patients with delayed methotrexate elimination. It serves to determine plasma levels of methotrexate, leucovorin and their metabolites, 7-hydroxymethotrexate, 2,4-diamino-N10 -methylpteroic acid and 5-methyltetrahydrofolic acid. For the determination of high concentrations (>10 microM) protein precipitation by acetonitrile will suffice for sample preparation. All other samples undergo solid-phase extraction and upgrading on C18 columns. Aminopterin, a therapeutic antecedent of methotrexate, serves as internal standard. Detection is done on a UV detector with a 300 nm filter. Five hundred microl of serum are needed to determine 0.2 microM of a specified substance (0.5 microM 5-methylterahydrofolic acid) with good precision and accuracy. For peak levels, 20 microl of capillary serum are sufficient.

Antimetabolites, Antineoplastic↗

Identification and elimination of polysiloxane curing agent interference encountered in the quantification of low-picogram per milliliter methyl tert-butyl ether in blood by solid-phase microextraction headspace analysis.

Widespread use of the gasoline additive methyl tert-butyl ether (MTBE) and the subsequent human exposure that follows have led to the need to quantify MTBE in a variety of complex biological matrixes. In this work, we demonstrate our latest MTBE quantification assay for whole blood and uncover previously unidentified contamination sources that prevented routine quantification in the low picogram per milliliter (parts per trillion, ppt) range despite a sensitive and selective analytical approach. The most significant and unexpected sources of contamination were found in reagents and laboratory materials most relevant to sample preparation and quantification. In particular, significant levels of MTBE were identified in sample vial septa that use poly(dimethylsiloxane) (PDMS)-based polymers synthesized with peroxide curing agents having tert-butyl side groups. We propose that MTBE is one of the byproducts of these curing agents, which cross-link PDMS via the methyl side groups. Residual MTBE levels of approximately 20 microg/septa are seen in septa whose formulations use these curing agents. Fortunately, these levels can be significantly reduced (i.e., <0.2 ng/septa) by additional processing. Performance achieved with this sample preparation approach is demonstrated using a mass spectrometry-based method to quantify blood MTBE levels in the low-ppt range.

Air Pollutants↗

Synthesis and properties of compressed dihydride complexes of iridium: theoretical and spectroscopic investigations.

Reaction of [Cp*Ir(P-P)Cl][B(C6F5)4] (P-P = bisdimethydiphosphinomethane (dmpm), bisdiphenyldiphosphinomethane (dppm)) with [Et3Si][B(C6F5)4] in methylene chloride under 1 atm of hydrogen gas affords the dicationic compressed dihydride complexes [Cp*Ir(P-P)H2][B(C6F5)4]2. These dicationic complexes are highly acidic and are very readily deprotonated to the corresponding monohydride cations. When the preparative reaction is carried out under HD gas, the hydride resonance exhibits JHD = 7-9 Hz, depending upon the temperature of observation, with higher values of JHD observed at higher temperatures. A thermally labile rhodium analogue, [CpRh(dmpm)(H2)][B(C6F5)4]2, was prepared similarly. A sample prepared with HD gas gave JHD = 31 Hz and J(HRh) = 31 Hz, allowing the Rh complex to be identified as a dihydrogen complex. Quantum dynamics calculations on a density functional theory (DFT) potential energy surface have been used to explore the structure of the Ir complexes, with particular emphasis on the nature of the potential energy surface governing the interaction between the two hydride ligands and the Ir center.

Journal Article↗

Analysis of sweet diterpene glycosides from Stevia rebaudiana: improved HPLC method.

An improved analytical method was developed which may be applied to quality control of stevioside and rebaudioside A contents in dried leaves of Stevia rebaudiana before processing; in a selective sampling program searching for plants of higher yield in diterpene glycosides content; or when a large number of samples are sent to the laboratory for analysis. The procedure developed involves two steps: solvent extraction followed by an isocratic HPLC analysis. The sample, 1 g of dried leaves of S. rebaudiana, is ground and solvent-extracted with EtOH 70% (w/w) in Erlenmeyer flasks by shaking for 30 min in a 70 degrees C water bath. After the extract was cooled, it was filtered and analyzed by HPLC using an NH(2) column (250 x 4.6 mm) and a mixture of acetonitrile/water (80:20, v/v) as mobile phase, pH 5 adjusted with acetic acid. The detection was in the UV range at 210 nm (0.04 AUFS). Quantitation was performed by means of an external standard calibration curve for each analyte which had been obtained from standard solutions of pure stevioside and rebaudioside A. Working under these conditions there were no observed interference effects. The method saves time in sample preparation, and reduces sample handling and chromatographic analysis time, while having little loss of precision [coefficient of variation (CV%) between 1.8% and 3.0%] and recovery [between 98.5% and 100.5%]. The method was applied to 30 samples of S. rebaudiana from Misiones (Northeastern Argentina), and the stevioside content found ranged between 3.78 and 9.75% (weight) whereas Rebaudioside A content ranged between 1.62 and 7.27% (weight).

Chromatography, High Pressure Liquid↗

A high-performance liquid chromatographic microassay employing a liquid-solid extraction technique for etintidine in plasma.

This paper describes a new, rapid solid extraction method for the determination of etintidine in plasma. The method employs a semiautomatic sample preparation system. Plasma samples and the internal standard (cimetidine) were applied onto octyl-bonded silica extraction columns. The extraction columns were then subjected to Tris buffer and water wash and were subsequently loaded onto an automatic sample injection system. The contents of the extraction columns were eluted on-line with a mobile phase of acetonitrile:methanol:0.1% ammonium hydroxide (85:10:5, by volume) onto a silica analytical column and detected by UV absorption at 229 nm. The chromatographic condition separates etintidine from some of its metabolites and other endogenous components in plasma. The detection limit for etintidine was 0.02-0.05 microgram/ml when 0.2 ml of plasma was used. This method has been used for the determination of plasma etintidine levels in humans and mice after oral administration of etintidine and was found to be suitable for pharmacokinetic/bioavailability studies of etintidine in humans and animals. The method can also be used for the quantitative determination of cimetidine and certain metabolites of etintidine.

Animals↗

Comparison of zinc reduction with platinum reduction for analysis of deuterium-enriched water samples for the doubly labeled water technique.

OBJECTIVE: Isotope ratio mass spectrometry of hydrogen and oxygen is frequently used to determine total energy expenditure (TEE) using doubly labeled water. Conventionally, hydrogen isotope ratio is determined in hydrogen gas generated from water samples using zinc reduction. We compare this with a new automated platinum method to determine the ratios of hydrogen isotopes in deuterium-enriched water samples. RESEARCH METHODS AND PROCEDURES: The platinum method of sample preparation was compared with the zinc method in three ways: analytical variation in deuterium enrichment (within sample; n = 51), analytical variation in TEE estimates (within sample set; n = 10), and level of agreement of TEE estimates between both methods (n = 14). RESULTS: For the zinc method, the standard deviation for multiple sets of triplicate 2H2O sample analysis was +/-4.36 per thousand and +/-2.07 per thousand for platinum. The correlation between TEE estimates when sample sets were analyzed in duplicate was r = 0.89 for zinc and r = 0.83 for platinum. The intercept and slope of the regression line were significantly different from the line of identity for duplicate TEE estimates by zinc but were not different from the line of identity for platinum. After correction for the intra-assay variation of each method, the correlation between zinc and platinum for TEE was 0.77, and the intercept, but not the slope, of the regression was significantly different from the line of identity. The mean difference between the zinc method and the platinum method was 56 kcal/day, and the 95% confidence interval was -438 to 550 kcal/day. DISCUSSION: These data suggest that the platinum method is at least as reliable as the zinc method as a sample preparation technique for isotope ratio mass spectrometry of deuterium-enriched water samples. The platinum method is also less costly and less labor-intensive than the zinc method.

Autoanalysis↗

Development and evaluation of analytical methodology for the determination of aflatoxins in palm kernels.

A rapid, simple and reproducible method for the simultaneous estimation of aflatoxins AFB1, AFB2, AFG1 and AFG2 in palm kernel samples has been developed by optimizing the sample preparation, solvent extraction, sample clean-up and quantification procedures. The aflatoxins are extracted from a slurried palm kernel sample with an acetone-water (80 + 20, v/v) mixture and the crude extract is cleaned up by solid-phase extraction using a phenyl bonded phase cartridge. The extract is passed through the cartridge with a water-methanol (93 + 7) mixture. Subsequent elution of the aflatoxins retained on the cartridge is achieved with a 3 ml aliquot of chloroform. The aflatoxin content of the eluate is quantified using a bi-directional high-performance thin-layer chromatography procedure. A critical evaluation of the proposed method was carried out by statistical comparison with the British Standard Method. The proposed procedure was shown to be more efficient and precise. Consistent recoveries of over 90% were achieved from spiked palm kernel extracts and detection limits were found to be 3.7, 2.5, 3.0 and 1.3 micrograms kg-1 for AFB1, AFB2, AFG1 and AFG2 aflatoxins, respectively.

Aflatoxins↗

Infrared matrix-isolation spectroscopy using pulsed deposition of p-H2.

We employed pulsed deposition of p-H2 onto a cold target to form a matrix sample suitable for measurements of infrared absorption. Unlike the method of rapid vapor deposition at approximately 2.5 K, developed by Fajardo et al., this method can be performed at a temperature as high as 5.5 K, achievable with a closed-cycle refrigerator; pumping on liquid helium in a cryostat is eliminated. Compared with the enclosed-cell method developed by Oka, Shida, Momose, and co-workers, this method is more versatile in sample preparation, especially for samples at a greater concentration or with high reactivity. Two experiments were tested: the pulse-deposited sample of CH4/p-H2 yields an infrared absorption spectrum nearly identical to that recorded with rapid vapor deposition, and a sample of vinyl chloride (C2H3Cl) in solid p-H2 irradiated with laser emission at 193 nm yields C2H5, in contrast to formation of HCl, C2H2, and a complex of HClC2H2 observed upon photolysis of C2H3Cl in an Ar matrix. These experiments are also compared with those with n-H2 or Ne as the matrix host.

Journal Article↗

Increased radon detection sensitivity: extraction from 200 ml of water and liquid scintillation counting.

To increase detection sensitivity in a radon ground-water monitoring program, radon is extracted and transferred from 200 mL of water to a liquid scintillator by bubbling and circulating air through the two liquids in a closed system using a peristaltic pump. This results in a count rate that is 11 times higher than for samples prepared by the most widely used method, where 10 mL of water are added to 10 mL of scintillator. Preparation of counting samples is simple and takes 4 min. Standard deviation in radon concentration is 5% and minimum detectable activity is 5 mBq L(-1), using a counter with a background of 3 counts per hour and a counting time of 3 h. This method is also suitable for the measurement of radium in water.

Equipment Design↗

Design of a 5' exonuclease-based real-time PCR assay for simultaneous detection of Bacillus licheniformis, members of the 'B. cereus group' and B. fumarioli in gelatine.

AIMS: The design of a fast, sensitive and specific detection method for Bacillus licheniformis, members of the 'B. cereus group' and B. fumarioli in gelatine. METHODS AND RESULTS: Specific Taqman probes were designed and tested in a real-time PCR setting. A specific fluorescent signal could be obtained for all gelatine isolates attributed to these species in one single real-time PCR reaction. After sample preparation, a gelatine sample spiked with 1 CFU provided enough template DNA for a significant signal. CONCLUSION: The potential of a real-time PCR assay for simultaneous detection of B. licheniformis, members of the 'B. cereus group' and B. fumarioli in gelatine is demonstrated. SIGNIFICANCE AND IMPACT OF THE STUDY: Implementation of the assay in gelatine producing plants may shorten delivery terms and inform on hazards to public health and suitable remediation procedures.

Bacillus↗

Approaches and constraints to identification and quantitation of asbestos fibers.

Asbestos fibers, members of complex crystal-chemical systems, possess some range in characteristic properties. Identification of fibers requires morphological, structural, and chemical data. Most current work centers on identification of single, sublight-microscopic fibers present as contaminants in a range of media. Constraints encountered in the analysis of such materials are: sample preparation of the differing media; level of fiber exposure (contamination); presence (kind and amount) of other particles; tissue types and their different preparation techniques; homogeneity of samples and their preparations; use of proper instrumental technique; time required for analysis, and quantitation.

Air Pollutants↗

Freeze substitution technique for identifying liposomes incorporated in emulsion and gel preparations.

The freeze-substitution technique was utilized for identifying unilamellar and multilamellar liposomes incorporated in gel or emulsion preparations. Samples of each preparation were rapidly frozen in liquid propane and the ice formed in the process was substituted with acetone containing 2 per cent osmium tetroxide at -70 degrees C. Electron micrographs obtained by both freeze-fracture and freeze-substitution methods showed the presence of either small unilamellar or multilamellar vesicles in all the liposome preparations. Results clearly demonstrated that freeze-substitution is a simple and cost-effective technique in comparison to the traditional freeze-fracture method and can be successfully used to characterize liposomes incorporated in dermatological or cosmetic vehicles.

Emulsions↗

Determination of moisture in cheese and cheese products.

Variables related to oven-drying samples of cheese and cheese products to determine moisture content were examined to provide more efficient and reproducible methods. Over 6500 samples of cheese were analyzed in an effort to modify the current AOAC procedure. The gravity atmospheric oven was unsuitable for use in accurate moisture analysis because of wide temperature differentials within the oven cavity. Use of this for oven moisture determination resulted in higher variance, which corresponded to the high temperature variation within the oven. Cheese sample preparation using an Oster blender yielded consistently lower variance in final moisture content than did preparation of cheese samples with a hand grater, rotary grater, and plug and plunger. Sample size of 3 +/- 0.25 g maximized surface area-to-volume ratios and yielded a lower error in final moisture content because of better control of ambient weight loss rates. Use of combination of disposable 5.5 cm diameter aluminum sample pans with 5.5 cm diameter glass fiber filter pads for covers produced a smaller standard deviation for moisture analysis than did the AOAC pan and insert cover and filter paper covers. All pans must be pre-dried for at least 3 h at 100 degrees C, and the glass fiber covers should be pre-dried for 1 h under the same conditions. All dried pans and covers must be stored in a desiccator with active desiccant. Equipment upgrades from the existing AOAC standard methods provide safer more efficient methods of analysis.

Algorithms↗

[SEM observation of treated dentin surface].

Various pretreatments have been attempted to make a polymer bond strongly to dentin. The results of these pretreatments are generally evaluated by SEM or TEM observation. The SEM results sometimes do not lead to the exact evaluation of those pretreatment agents and methods, since artifact arisen during the preparation of SEM samples might conceal the effects of them. However, it could be useful for the discussion of treatments to appreciate the artifact. Thus, by SEM observation we investigated the fine structure of dentin affected by the different sample preparation method.

Acid Etching, Dental↗

Amino acid analysis by capillary gas chromatography.

Two developments have enabled major advancements in the use of capillary gas chromatography (GC), the result being its much more widespread use in investigations on a broad range of chemical and biological problems. The 2 technological developments were the introduction of fused silica capillary columns and the development of immobilized stationary phases for capillary GC columns. Because fused silica columns with immobilized stationary phases of varying polarities are offered by numerous vendors of chromatographic equipment, they have become widely used for many analytical tasks. We conducted a study to compare the effectiveness of commercially available fused silica capillary columns with the classical ion-exchange method in the separation and quantitation of amino acids. We selected the N-trifluoroacetyl (TFA) n-butyl and the N-heptafluorobutyryl (HFB) isobutyl ester derivatives for this study because of the extensive research and application of these derivatives during the past 20 years. The amino acid content of hydrolysates of 5 materials was measured: ribonuclease, beta-lactoglobulin, lysozyme, soybean meal, and a commercial poultry feed. Single 6N HCl hydrolysates of each material were prepared to minimize sample preparation differences, and 3 independent analyses of each hydrolysate were made by each of 3 techniques: the N-TFA n-butyl and N-HFB isobutyl ester methods using capillary gas chromatography and the ion-exchange chromatographic method using a Beckman 121 M amino acid analyzer. Our results clearly demonstrate that capillary GC analysis of amino acids using fused silica bonded-phase columns provides data with good precision and in general excellent agreement with ion-exchange analyses.

Amino Acids↗