Closed correction of systemic semilunar valve insufficiency in the neonate.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We report a case of postoperative intracardiac shunts across the membranous septum detected by Doppler echocardiography and discuss the anatomical basis for the development of such a complication.
Soft and hard tissue defects of the cranio- and maxillofacial area, especially after an avulsion injury, are challenging to reconstruct. Sophisticated soft and hard tissue transfer techniques have allowed satisfactory reconstruction of the gross anatomic structure. However, these methods do not allow optimal restoration of fine anatomic detail or function. The advent of dental implants and modified dental implants for craniofacial applications has allowed maximization of cosmetic and functional restoration. Prosthodontists are capable of fabricating subunits of the cranio- and maxillofacial area with fine detail, reproducing the coloring, texture, and idiosyncrasies of a patient's native skin. Dental implant technology has allowed these prostheses to be bone anchored, yielding a reproducible and stable attachment. This method of attachment in turn allows flexibility in the design of the prosthesis, to maximize restoration, and imparts an increased sense of confidence to the patient. Illustrated are six examples demonstrating the versatility of dental implants in the reconstruction of avulsion injuries of the cranio- and maxillofacial complex.
Invasive treatment for nutcracker syndrome is controversial, especially in patients with a pediatric onset. Most patients are treated conservatively for a relatively long time, but severe hematuria with an intermittent exacerbation remained unchanged. Three pediatric patients presented with hematuria associated with or without mild proteinuria and were diagnosed as having nutcracker syndrome. The authors performed self-expandable endovascular stent placement across the left renal vein in these pediatric patients. Severe gross hematuria completely subsided after treatment and no serious complications are noted during 2- or 3-year follow-up; moreover, all patients have good physical development.
Explore the source record for details and available documents.
OBJECTIVES: The purpose of this study was to determine whether multiplanar (MP) transesophageal echocardiographic views were superior to standard views (ST), in the evaluation of mitral prosthesis regurgitation (MR), particularly in presence of wall regurgitant jets. METHODS: We studied all mitral prostheses (n = 43) in which pathological mitral regurgitation had been detected by multiplanar TEE between January 1993 and March 1994. Regurgitant prostheses were classified in two groups according to the presence of wall regurgitant jets and maximum turbulent color flow areas (Amax.) were measured on standard (0 and 90 degrees) and MP (0 to 180 degrees) views. RESULTS: The Amax. detected on ST views were 5.80 +/- 4.60 cm2 and on MP 7.42 +/- 5.13 cm2. Student's test was used to compare both areas and significant differences were found: 1.61 cm2; 95% confidence interval from 0.94 to 2.28 cm2; p = 0.000025. The sample was divided in two groups, A (n = 33): with wall jets and B (n = 10): without wall jets. The Amax. for group A was 5.64 +/- 4.30 cm2 in ST views, and 7.51 +/- 5.12 cm2 in MP. The difference was statistically significant: 1.86 cm2, 95% c.i. from 1.04 to 2.68 cm2; p = 0.00009. Differences for group B were also statistically significant: 0.68 cm2; p = 0.0172. MP views detected a bigger regurgitant area in 26 of the 43 cases (60%). The difference between ST and MP views was significantly bigger for group A than for group B: mean 1.18 cm2; p = 0.0176. MP views detected a severer degree of MR, classified as mild moderate and severe according to the color flow area, than ST views in 8 patients. All of them had wall regurgitant jets. Three had been considered normal on ST views. CONCLUSION: We conclude that MP transesophageal views are significantly superior to ST in the assessment of regurgitant prosthetic mitral valves, particularly in presence of wall regurgitant jets. Our data strongly suggest that multiplanar TEE is the procedure of choice in the assessment of wall regurgitant mitral prostheses.
The authors describe various applications of scintigraphy with labeled leukocytes and its value in the diagnosis of gut diseases such as Crohn's disease, ulcerative colitis and related complications. Furthermore, the study of vascular prosthesis infection, cryptogenetic fever and abdominal sepsis, three cases of which are herein reported, is facilitated. The method, in conjunction with endoscopy and traditional radiology, revealed to be of great value in terms of sensitivity and specificity for the diagnosis of the aforementioned diseases. Therefore, the use of such method is encouraged in all those cases of abdominal sepsis of uncertain interpretation and in the evaluation of vascular prosthesis infection.
BACKGROUND: Unlike vein bypasses, the role of duplex surveillance of infrainguinal prosthetic bypass grafts is controversial. The purpose of this study was to evaluate the adequacy of color duplex surveillance in identifying failing infrainguinal polytetrafluoroethylene (PTFE) bypass grafts and to assess its value in predicting continued bypass patency. METHOD: The surveillance data of primarily patent PTFE bypass grafts were compared with those of revised/occluded PTFE grafts. Ninety-five patients underwent 102 infrainguinal PTFE bypass grafts from January 1991 to December 1996 and were enrolled in a duplex surveillance program at 1 month postoperatively, every 3 months in the first year, every 6 months in the second year, and yearly thereafter. RESULTS: Seventy grafts remained primarily patent, 5 were revised and 27 occluded. There was no significant difference in the mean age, gender, indication for surgery, type of original procedure, or duration of follow-up between both groups. Four hundred and seven duplex surveillance data were available for analysis. Focal increase in peak systolic velocity (PSV) 3 x the adjacent segment or low flow manifested by PSV <45 cm/sec were considered abnormal. In the primarily patent group, 5 bypasses had abnormal duplex surveillance and were found to have no abnormality on angiogram and remained patent during the study period. In the revised/occluded group, duplex surveillance was abnormal in 8 bypasses. Twenty-four bypasses occluded without any predicting abnormalities on their last duplex examination, which was performed within 3 months from the occlusion in the majority of the patients. In the 27 occluded bypasses, no intervention was necessary following the occlusion in 7 grafts because of mild or no symptoms. Two patients were treated with a primary amputation and 2 had new bypasses. In 16 occluded grafts, salvage of the PTFE bypass was attempted. Ten of these grafts were patent at the end of the follow-up. The sensitivity of duplex surveillance was 25% with a positive predictive value of 61.5%. CONCLUSION: Duplex surveillance of infrainguinal PTFE bypass grafts has a low yield and is inadequate at predicting continued bypass patency.
There is a major difference in thrombogenicity between lower extremity prosthetic and autologous vein bypass grafts, and arterial blood flow shear rate is known to influence thrombus formation. Despite this association, there has been little direct clinical observation of shear rates in bypass grafts. The authors developed a new noninvasive method to quantitate human arterial shear rate and used it in a pilot study to characterize differences in lower extremity bypasses. Shear rates were measured in 10 prosthetic and 14 autologous vein femoropopliteal bypass grafts. With CVI-M-mode color flow ultrasonography in resting supine patients, a velocity profile was recorded from a midgraft longitudinal section in the ultrasound beam direction. Shear rates were calculated by using a mathematical-graphic computer program at the anteromedial (near) and posterolateral (far) graft walls by averaging values immediately before and after peak systolic velocity (PSV). Comparison between prosthetic and autologous graft groups respectively revealed that differences in age (67 +/- 12 [SD] vs 71 +/- 10 yr), male gender (60% vs 43%), prevalence of hypertension (50% vs 71%), diabetes (40% vs 64%), smoking (50% vs 50%), hypercholesterolemia (30% vs 29%), coronary artery disease (60% vs 50%), and critical ischemia (60% vs 86%) did not reach statistical significance (p>0.19). Median PSVs were significantly less in prosthetic than in autologous vein bypasses (37 +/- 13 vs 57 +/- 22 cm/s, p=0.018). Prosthetic and autologous graft diameters were not statistically significantly different (6.3 +/- 1.1 vs 5.6 +/- 1.3 mm, p = 0.18). Shear rates were significantly less in prosthetic than in autologous vein bypasses both at the near wall (382 +/- 146 vs 698 +/- 271 s(-1), p=0.003) and at the far wall (551+/-235 vs 827+/-339 s(-1), p-0.037). This mathematical model can be used to calculate shear rate from observed ultrasound flow patterns. Prosthetic bypass grafts had lower shear rates than autologous vein grafts.
AIM: The aim of this study was to examine the results of remote superficial femoral artery endarterectomy (RSFAE) in conjunction with distal aSpire stenting in a multinational study. METHODS: RSFAE is a minimally invasive procedure performed through a limited groin incision. A total of 210 patients were included in this study. The indications for the procedure were claudication in 158 (75%) patients and limb salvage in 52 (25%). After RSFAE the outflow tract atheromatous plaque was ''tacked'' with the aSpire stent, which is an expanded polytetrafluoroethylene (ePTFE) covered nitinol stent with high radial strength, yet it is flexible enough to withstand the compressive forces at the knee joint. Prior to stent deployment, if the stent position is not in optimal position, it can be ''wrapped down'', repositioned and re-expanded. Therefore, not only is the plaque end point tacked, but the collaterals are preserved as well. All patients underwent follow-up examination with serial color-flow duplex ultrasound scanning. RESULTS: The mean length of endarterectomized superficial femoral arteries (SFAs) was 28.2+/-6.2 cm (range 15-43 cm). The primary cumulative patency rate by means of life-table analysis was 60.6+/-4.8% (SE) at 33 months, (mean 17.1 months; range 1-33 months). During follow-up percutaneous transluminal balloon and/or stent angioplasty was necessary in 50 patients for a primary assisted patency of 70.2+/-4.8% at 33 months. The locations of the restenosis after RSFAE were evenly distributed along the endarterectomized artery. There were 2 deaths (myocardial infarctions), 12 (5.7%) wound complications (7 hematomas, 5 skin edge sloughs) and the mean hospital length of stay was only 1.3+/-0.5 days. CONCLUSION: RSFAE with distal aSpire stenting is a minimally invasive, safe durable procedure for the treatment of long-segment SFA occlusive disease.
Between July 1996 and July 1998, 34 patients (female n = 16, male n = 18) were scheduled for catheter--interventional occlusion (ASDO) of an atrium septum defect of secundum type (ASD II). Median age was 7.9 years (2.5-54.6), weight 23.1 kg (9-97). 9 defects were closed with "Angel Wings" (AW) and 25 ASD occlusions were attempted with "CardioSeal" (CS). 30 patients had simple ASD II, 3 persisting foramen ovale with suspected paradoxal cerebral embolization and 1 significant residual shunt at atrial level after corrective heart surgery for interrupted aortic arch type B. ASDO was successful in 31/34 cases (91%). One CS was removed surgically due to significant left to right shunt after release and two CS devices were withdrawn back into the sheath. Median ASD diameter was 11.9 mm (6-16), balloon occlusive diameter was 15 mm (6-20) and median left to right shunt was 40% (6-64%). On follow up minimal left to right shunt was seen in 5/31 patients (16%). In selected patients catheter--interventional ASDO may be a good alternative to surgical ASD closure.
66 patients with congenital or acquired amputations of the hand have been studied after fitting partial or complete silicone hand prostheses which can be manufactured at relatively low cost. Most patients used their prostheses on social occasions only and all but four expressed satisfaction with them.
OBJECTIVES: We sought to characterize a region of apparent systolic flow resembling mitral regurgitation (MR) in patients with mechanical disk mitral prostheses as artifact. BACKGROUND: Diagnosing MR in the presence of mechanical prostheses is challenging. Occasionally, important MR is suggested by a substantial region of systolic Doppler color flow in an acoustically shadowed region of the left atrium when, in fact, only trace MR exists. We hypothesized this pseudo-MR is caused by acoustic mirroring of the left ventricular outflow tract (LVOT) flow by sound reflected off the prosthesis, projecting flow into the left atrium because of longer transit time. METHODS: We reviewed 19 patients with mechanical mitral valves and trace MR by transesophageal echocardiography who had transthoracic echocardiography studies within 1 week (group A), and prospectively studied 22 consecutive patients by transthoracic echocardiography with subtle transducer angulation variation to detect pseudo-MR and characterize it by pulsed Doppler (group B). RESULTS: In group A, 12 of 19 patients had evidence of pseudo-MR on review of their transthoracic echocardiograms, absent by transesophageal echocardiography. In group B, this pseudo-MR signal was present in 13 of 22 patients, with velocity and timing by pulsed Doppler comparable with LVOT flow (onset at 125 +/- 27 milliseconds vs 135 +/- 11 milliseconds from QRS, P = not significant). The angle between the mitral plane and the LVOT, which determines whether this mirroring can occur, was smaller for patients with pseudo-MR. CONCLUSION: Artifactual pseudo-MR is often seen with mechanical mitral prostheses. Its behavior and sensitivity to geometric relationships are consistent with mirroring of LVOT flow. Practically, potential misdiagnosis can be readily avoided by pulsed Doppler sampling, sparing the patient further procedures.
Imaging is an essential component of endoluminal aneurysm repair. Detailed imaging with computed tomography, magnetic resonance imaging and angiography, alone or in combination, is required for the initial assessment and planning. Careful, lifelong follow-up is essential since complications of endoluminal repair may take months or years to appear. Follow-up imaging requires a combination of plain film radiography, colour Doppler ultrasound and helical computed tomography. Magnetic resonance imaging may be valuable for the follow-up of non ferro-magnetic endografts and intra-arterial angiography will be required for specific cases.
OBJECTIVES: Interposition vein cuffs improve the patency of below-knee ePTFE arterial grafts, and there is evidence that they do so, at least in part, by modifying the distribution of myointimal hyperplasia (MIH) at the distal anastomosis. Alteration of local haemodynamics is one of the mechanisms which might be involved. The purpose of this study was to characterise the local haemodynamics within an interposition vein cuff. MATERIAL AND METHODS: Flow patterns have been analysed in a laboratory model of cuffed anastomosis and compared with observations made in patients by cine intra-arterial digital subtraction angiography (IA DSA) and dynamic colour duplex scanning. RESULTS: In contrast to non-cuffed anastomoses in which the flow is predominantly laminar, cuffed anastomoses are associated with the formation of a coherent vortex. CONCLUSION: High frictional forces or shear stress exerted upon the arterial wall by the vortex could explain the beneficial effect of a cuff upon anastomotic MIH, in which case the optimal configuration of small vessel anastomoses would be that which most effectively promotes the formation of this type of vortex.
OBJECTIVES: To evaluate a surveillance programme based on colour duplex ultrasound scanning of above-knee prosthetic femoropopliteal bypass. DESIGN: A retrospective clinical study. MATERIALS: One hundred and eighteen above-knee prosthetic femoropopliteal bypass procedures performed from 1993 to 1996. METHODS: Scans were done at 1, 3, 6 and 12 months, and annually thereafter. Significant graft-related stenotic lesions were defined as 50% diameter reduction or more located at the inflow or outflow arteries, or associated with the graft. Identified lesions were treated by angioplasty or surgical repair. RESULTS: The primary and secondary patency rates at 2 years were 55% and 71%, respectively. Stenotic lesions were documented on 45 of 463 scans (9.7%). Twenty-nine grafts (25%) were treated and only six of these grafts (21%) occluded. This was significantly superior to the occlusion rate of 41% for the whole series. CONCLUSIONS: It appears that one-quarter of above-knee prosthetic femoropopliteal bypasses develop graft-related stenoses. The favourable prognosis of these grafts after treatment for stenotic lesions justifies a surveillance programme. However, most graft occlusions seem to occur in grafts where no stenotic lesion has been previously detected.
AIMS: To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects. METHODS: Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter closure of their atrial septal defects at a mean+/-SD age of 30. 8+/-18.6 years (range 3.7-65.9 years) and mean weight of 56.6+/-25.5 kg (range 12.9-99 kg) using two Amplatzer devices implanted simultaneously via two separate delivery systems. During catheterization, two dimensional transoesophageal echocardiography was performed in all but one patient, during and after transcatheter closure, while three dimensional transoesophageal echocardiography was performed in six patients before and after transcatheter closure. RESULTS: Forty-four devices were deployed in all patients to close 45 defects (one patient with three defects closed by two devices). Two dimensional transoesophageal echocardiography was helpful in selection and in guiding correct deployment of the devices. The mean size of the larger defect, as measured by transoesophageal echocardiography was 12.8+/-5.9 mm and the mean size of the smaller defect was 6.6+/-3.0 mm. The mean size of the larger devices was 15+/-7.5 mm, and 8.4+/-3.7 mm for the smaller. Three dimensional transoesophageal echocardiography provided superior imaging and demonstrated the number, shape and the surrounding structures of the atrial septal defects in one single view. The median fluoroscopy time was 28.7 min. Device embolization with successful catheter retrieval occurred in one patient. Forty-four devices were evaluated by colour Doppler transoesophageal echocardiography immediately after the catheterization with a successful closure rate of 97.7%. On follow-up colour Doppler transthoracic echocardiography demonstrated successful closure in 97.5% at 3 months. CONCLUSIONS: The use of more than one Amplatzer septal occluder to close multiple atrial septal defects is safe and effective. The use of two- and three-dimensional transoesophageal echocardiography provided useful information for transcatheter closure of multiple atrial septal defects using two devices. Three-dimensional transoesophageal echocardiography enhanced our ability to image and understand the spatial relationship of the atrial septal defect anatomy.
The explosion of high-resolution imaging technology in recent years has led to the increasing problem of choosing imaging modalities appropriate to specific clinical questions. In terms of structural information, for example, the relative benefits of ultrasound versus magnetic resonance imaging versus computed tomography scanning are often readily apparent, but in the related area of flow velocity imaging, difficulties may arise. These are perpetuated by the relative lack of information on the fundamental display characteristics of these imaging techniques. Much of this essential information can be acquired from in vitro modeling of the pressure and flow characteristics of a variety of pathologic lesions. The information obtained from such experimental investigation can provide a basis for a more rational approach to the interpretation of these imaging modalities in the clinical setting. We review the recent role of in vitro modeling for enhancing our understanding of the display characteristics of various imaging technologies, with particular emphasis on Doppler ultrasound and color Doppler flow mapping where in vitro modeling has been most extensively studied.