Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Monitoring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

Self-reported seizure frequency and time to first event in the seizure monitoring unit.

PURPOSE: To compare seizure frequency reported in the clinic with time to first diagnostic event during video-EEG monitoring. The effect of the artificial environment of the monitoring unit on self-reported seizure frequency was explored. METHODS: The 155 consecutive patients were seen in the Washington University Epilepsy Center and subsequently underwent video-EEG monitoring during 2001. Of these, 112 had a diagnostic event during monitoring; 31 left without having a definite event; and 12 could not provide an estimate of seizure frequency in the clinic. The time to first event was compared with self-reported seizure frequency. The patients were then divided into three equal groups (tertiles) based on mean seizure frequency, and time to first seizure was compared between groups. Then the numbers of patients staying >7 days without ever having an event were compared between the low and high seizure-frequency groups. Finally, Kaplan-Meier survival curves were calculated. RESULTS: No correlation was found between self-reported seizure rate and time to diagnostic event (r= 0.18; p = 0.06). Time to first event was 2.8 days in the low seizure-frequency group (mean, 2.2/month), 2.1 days in the medium (mean, 8.8/month), and 2.1 days in the high (mean, 24.1/month) groups, which were not significantly different (p = 0.19). Of patients in the low-frequency group, 79% had an event within 7 days. CONCLUSIONS: In the artificial environment of the monitoring unit, self-reported outpatient seizure frequency is not an accurate predictor of duration of video-EEG monitoring required to make a definitive classification of clinical events and should not contribute to the decision as to whether to refer a patient for monitoring.

Adolescent↗

Noninvasive hemodynamic monitoring of critical patients in the emergency department.

OBJECTIVE: To evaluate the feasibility of multicomponent noninvasive hemodynamic monitoring in critical emergency patients and to compare this technique with simultaneous invasive monitoring by the pulmonary artery thermodilution catheter. METHODS: A prospective observational study was done comparing invasive monitoring and noninvasive monitoring in 60 critically ill or injured patients who required hemodynamic monitoring shortly after entering the ED of a university-affiliated country hospital. Cardiac output (CO) values measured by the standard thermo-dilution pulmonary artery catheter technique were compared with simultaneously obtained measurements using a noninvasive bioimpedance method. Concurrent measurements were made of pulse oximetry to screen pulmonary function and transcutaneous oximetry to assess tissue perfusion. RESULTS: The impedance CO values closely approximated those for the thermodilution method; r 0.81, p < 0.001. Significant circulatory abnormalities, including hypotension, reduced cardiac index, arterial hemoglobin desaturation, tissue hypoxia, reduced O2 delivery, and consumption, were found in 54 of the 60 (90%) patients. The cardiac index decreased in 44% of the patients, the transcutaneous O2 decreased in 39%, and the O2 saturation by pulse oximetry fell in 22% during the observation period in the ED (commonly lasting 2-8 hours). CONCLUSIONS: Noninvasive monitoring can provide hemodynamic and perfusion information previously available only by invasive thermodilution catheters. Such noninvasive monitoring can display continuous on-line real-time data, allowing immediate recognition of circulatory abnormalities and providing a means to titrate therapy to appropriate therapeutic goals.

Adult↗

Human biological monitoring of occupational genotoxic exposures.

Human biological monitoring is a valuable tool for exposure assessment in groups of persons occupationally exposed to genotoxic agents. If the monitoring activity covers genetic material the term genetic monitoring is used. The methods used for genetic monitoring are either substance specific, e.g. the quantitation of identified DNA-adducts or substance unspecific as is the measurement of DNA-repair. The sample material used for analysis must be well characterized and subject to uniform processing for comparison of the results. Confounding factors of smoking, age and sex must be well controlled for and the biomonitoring results should preferentially be linked with accurate ambient air monitoring. In persons occupationally exposed to styrene the endpoints of DNA-damage and DNA-repair in genetic monitoring are methods of choice in exposure situations above the current Danish (25 ppm) or Finnish (20 ppm) occupational exposure limit value of styrene in ambient air. The consideration of ethical issues in human genetic monitoring is an important but often overlooked aspect. This includes the scientific and preventional relevance of performing a test on individuals, pre- and post study information of donors and confidentiality as well as ownership of the results.

DNA Damage↗

Blood pressure control by home monitoring: meta-analysis of randomised trials.

OBJECTIVE: To determine the effect of home blood pressure monitoring on blood pressure levels and proportion of people with essential hypertension achieving targets. DESIGN: Meta-analysis of 18 randomised controlled trials. PARTICIPANTS: 1359 people with essential hypertension allocated to home blood pressure monitoring and 1355 allocated to the "control" group seen in the healthcare system for 2-36 months. MAIN OUTCOME MEASURES: Differences in systolic (13 studies), diastolic (16 studies), or mean (3 studies) blood pressures, and proportion of patients achieving targets (6 studies), between intervention and control groups. RESULTS: Systolic blood pressure was lower in people with hypertension who had home blood pressure monitoring than in those who had standard blood pressure monitoring in the healthcare system (standardised mean difference 4.2 (95% confidence interval 1.5 to 6.9) mm Hg), diastolic blood pressure was lower by 2.4 (1.2 to 3.5) mm Hg, and mean blood pressure was lower by 4.4 (2.0 to 6.8) mm Hg. The relative risk of blood pressure above predetermined targets was lower in people with home blood pressure monitoring (risk ratio 0.90, 0.80 to 1.00). When publication bias was allowed for, the differences were attenuated: 2.2 (-0.9 to 5.3) mm Hg for systolic blood pressure and 1.9 (0.6 to 3.2) mm Hg for diastolic blood pressure. CONCLUSIONS: Blood pressure control in people with hypertension (assessed in the clinic) and the proportion achieving targets are increased when home blood pressure monitoring is used rather than standard blood pressure monitoring in the healthcare system. The reasons for this are not clear. The difference in blood pressure control between the two methods is small but likely to contribute to an important reduction in vascular complications in the hypertensive population.

Arteries↗

Monitoring of the neonate undergoing MR imaging: technical considerations. Work in progress.

Instrument monitoring of vital signs in neonates undergoing magnetic resonance (MR) imaging can be difficult because of the unique environmental restrictions imposed by the imager. The authors present their experience with monitoring more than 50 newborn infants and discuss the interaction of monitoring devices with the MR imager. Several MR-compatible monitors allow continuous evaluation of body temperature, heart rate, blood pressure, and auscultation of heart sounds and respiration in mechanically ventilated infants. Signal-to-noise (S/N) ratio measurements taken during imaging of the head of an infant with these monitors in place did not differ appreciably from the ratio obtained during imaging without monitors. Tip angles should be optimized to account for widely varying head size among neonates, since adverse monitoring effects are significantly compounded by improper tip angle adjustment.

Body Temperature↗

Complications of invasive monitoring used in intractable pediatric epilepsy.

Invasive monitoring for intractable epilepsy is useful when the epileptogenic focus is in question even after an extensive noninvasive presurgical evaluation, or when the epileptogenic focus is located in or near eloquent cortex. From June 1989 to June 2001 at the Children's Hospital of Philadelphia, 64 children with intractable epilepsy underwent 67 invasive monitoring procedures as part of their presurgical evaluation. The average age at implantation was 10 years. In all but two cases, subdural strips and grids were used. Depth electrodes, when used, were placed stereotactically or under direct vision. The average duration of the monitoring period was 5.87 days. Every patient had intradural cultures sent during removal of the electrodes, and lumbar punctures were performed in 15 patients. Twenty-one patients had at least one episode of a CSF leak. Of the 67 patients, 10 had positive intradural cultures, only 1 of whom had a positive lumbar puncture and none of whom developed clinically significant meningitis. No clinically relevant hemorrhages occurred as a result of the invasive monitoring. One patient did have a transient visual field loss after placement of an occipital grid. While CSF leaks are common after invasive monitoring despite precautions, clinically significant CSF infections are uncommon and appear to be unrelated to the duration of monitoring, the occurrence of a CSF leak or the length of time the patient is on perioperative antibiotics. We conclude that invasive monitoring for intractable epilepsy is generally safe.

Adolescent↗

Access monitoring does not really improve outcomes.

It is widely accepted that hemodialysis access monitoring combined with preemptive percutaneous transluminal angioplasty (PTA) improves outcomes. The many studies that have evaluated monitoring during the last decade provide an opportunity to examine whether this hypothesis is valid. Because synthetic grafts are more likely than autogenous arteriovenous fistulas to benefit from monitoring, this review is restricted to grafts. Recent studies show that monitoring does not accurately predict graft thrombosis or failure, nor does it prolong graft life. However, monitoring can reduce thrombosis, and thereby reduce access-related hospitalizations and use of central venous dialysis catheters. Because preemptive PTA is expensive, however, monitoring does not reduce the cost of access-related care. The limited benefit that monitoring provides emphasizes the urgent need to develop better approaches to solving the problem of graft thrombosis and failure.

Angioplasty, Balloon, Coronary↗

Association of clinic vascular access monitoring practices with clinical outcomes in hemodialysis patients.

BACKGROUND: Early identification of access dysfunctions may be associated with improved patient outcomes. We examined whether patient outcomes were associated with vascular access monitoring practices in an incident dialysis cohort. METHODS: We conducted a national prospective cohort study and analyzed 363 hemodialysis patients who had a first permanent vascular access (arteriovenous fistula or graft) by 6 months after the start of dialysis. Multivariate methods were used to examine associations between monitoring practices and 6-month Kt/V (reaching Kt/V >/=1.2), access intervention, access failure, and 2-year septicemia and all-cause hospitalization and mortality. RESULTS: Patients who received monitoring weekly or more often (49%) were more likely to have an access intervention (adjusted RH = 1.40, 95% CI, 1.07-1.84) than those who received monitoring less frequently. Additionally, patients treated at clinics that reported performing regular access monitoring (80% of patients) were less likely to be hospitalized for septicemia (IRR = 0.35, 95% CI, 0.21-0.61) or for any cause (IRR = 0.77, 95% CI, 0.60-0.99). There were no statistically significant differences between patients exposed to different vascular access monitoring practices in access failure, achievement of Kt/V, or survival. CONCLUSION: Frequent monitoring of dialysis access may initially increase the number of interventions but is beneficial to longer-term outcomes, including septicemia-related and all-cause hospitalization.

Cohort Studies↗

Prevalence of sleep apnea among Japanese industrial workers determined by a portable sleep monitoring system.

We developed a new portable sleep monitoring system and studied the prevalence of sleep apnea syndrome among Japanese industrial workers. This device assessed three kinds of parameters: nasal airflow, tracheal sound and electrocardiogram (ECG), and digitally stored the clock time of the onset of apnea, apnea duration and R-R intervals by a built-in microcomputer. After monitoring, the portable sleep monitor was connected to a host computer, and apneic episodes, the so-called 'apnea index' as apneic episodes corrected by measuring time ('AI') and R-R intervals were analyzed. In 170 inpatients referred to our sleep clinic, sleep monitoring by this device was performed simultaneously with all-night polysomnography, and the sensitivity and specificity of this device was determined under different criteria of the apnea index (AI) (AI > 5, 10, 15 and 20 episodes/h) by polysomnography. In all AI criteria, the sensitivity was more than 90%, and the specificity was also reasonably high. Using this system, successive 2-night home sleep monitoring was performed on 168 healthy workers in one Japanese industrial company, and 159 people (140 males; 19 females) who had successful monitoring were analyzed. The percentage of persons who had 'AI' of more than 10 episodes/h was 7.5%. There were no significant correlations between 'AI' and age, body weight or scores estimated by sleep questionnaires. These results suggest that even in people who are seemingly healthy significant apneic episodes could be detected by the portable home sleep monitoring system. This system may therefore be useful in evaluating the occurrence of sleep apnea syndrome in general populations.

Adolescent↗

Ambulatory blood pressure monitoring and diagnostic errors in hypertension: a Bayesian approach.

Random variability of blood pressure complicates the diagnosis and subsequent treatment of hypertension. To evaluate the importance of the number of blood pressure measurements in the correct diagnosis and control of hypertension, the authors used a Bayesian model to estimate the true average blood pressure of a group of newly diagnosed hypertensives, then calculated the diagnostic error that would result from monitoring methods using 24 daytime measurements or from using only three random monitoring measurements. The study population consisted of 129 individuals with newly diagnosed mild hypertension according to standard criteria, who were also evaluated with an ambulatory blood pressure monitor. In true normotensives (daytime diastolic blood pressure <90 mm Hg), the negative predictive value with three measurements was 0.92, and it rose to 0.96 with monitoring methods. In mild hypertensives (90-104 mm Hg), the positive predictive value was 0.64 with three measurements and 0.84 with monitoring methods, thus reducing the rate of false mild hypertensives from 35% to 15%. Finally, in patients with moderate or severe hypertension (>104 mm Hg), the positive predictive value improved from 0.26 with three readings to 0.61 with monitoring methods. Similar results were observed with daytime systolic pressure measurements. As the number of measurements increased, the diagnostic error due to the random variability of blood pressure became progressively smaller. In cases of hypertension, the large improvement in predictive values may justify using monitoring methods to confirm standard diagnosis.

Adult↗

Wireless patient monitoring system for a moving-actuator type artificial heart.

In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

Cell Phone↗

Metabolic monitoring for patients treated with antipsychotic medications.

OBJECTIVES: Metabolic side effects of antipsychotic treatment include weight gain, dyslipidemia and increased susceptibility to diabetes. Patients with schizophrenia have increased coronary heart disease mortality and reduced life expectancy. There is an urgent clinical need to monitor antipsychotic-treated patients for metabolic disturbance. Our objectives were to review published international monitoring guidelines, establish goals for metabolic monitoring, and make recommendations for practice. METHOD: We reviewed the major published consensus guidelines for metabolic monitoring of patients treated with antipsychotic medications and selectively reviewed practice guidelines for the management of diabetes, dyslipidemia, and hypertension. RESULTS: Patients with serious mental illness have markedly elevated rates of metabolic disturbance and limited access to general medical care. Monitoring, but not necessarily medical treatment of metabolic disorder, falls within the scope of psychiatric practice and should include screening for metabolic disturbance as well as tracking the effects of antipsychotic treatment. In addition, psychiatrists and psychiatric services should work toward facilitating patients' access to medical care. There is considerable consensus in the published guidelines. Areas of dissent include which patients to monitor, the utility of glucose tolerance testing, and the point at which to consider switching antipsychotics. CONCLUSION: We encourage clinicians to adopt a structured system for conducting and recording metabolic monitoring and to develop collaborations with family physicians, diabetes specialists, dieticians, and recreation therapists to facilitate appropriate medical care for antipsychotic-treated patients.

Antipsychotic Agents↗

Electroencephalographic-video monitoring in neonates, infants, and children.

Electroencephalographic (EEG)-video monitoring is a valuable tool in the evaluation and management of neonates, infants, and children suspected of having seizures or those with confirmed epilepsy. Monitoring may provide the basis for detection, characterization, and quantification of seizures in each of these age groups. The basic functional components of monitoring include: EEG, polygraphic measures, video, and synchronization devices that assure that all recorded modalities can be precisely correlated in time. Monitoring techniques may vary depending on patient age, clinical condition, and clinical questions to be addressed. Specially designed instrumentation is required to perform monitoring; however, the role of the technologist is central in conducting a study with maximum clinical yield in the most efficient manner. The clinical neurophysiologist must recognize the specific objectives of each monitoring study and appreciate the age-dependent features of the EEG and the types of clinical paroxysmal events that may occur at different ages. Neonates, infants, and older children all demonstrate special features to be considered in the conduct and analysis of EEG-video monitoring.

Anticonvulsants↗

The usefulness of one to two hour video EEG monitoring in patients with refractory seizures.

Video EEG monitoring for 1-2 hours was performed on 100 outpatients (57 females and 43 males) with refractory seizures or frequent paroxysmal events. Patients' ages ranged from 8 days to 67 years (mean age 21). At least one clinical seizure or paroxysmal event was observed in 66 patients; 24 of these patients had subtle seizures that would be difficult to observe without videotape monitoring. The combination of videotape and EEG monitoring was able to confirm the diagnosis in 80 cases. The referral diagnosis was changed in 37 patients; they included changes in seizure types in 17 epileptic patients; 10 patients were found to have pseudoseizures and 10 patients had nonepileptic neurological disorders. The yield of EEG seizure activity differed significantly between video EEG monitoring and routine EEG recording (p < 0.001). EEG seizure activity was reported in 77 patients with video EEG monitoring compared to 49 patients with routine EEG recording. We conclude that outpatient video EEG monitoring yields more information on the presence or absence of seizures and their types, improving patient management, and averting the need for prolonged inpatient intensive monitoring.

Adolescent↗

Monitoring of brain tissue oxygenation following severe subarachnoid hemorrhage.

The purpose of this prospective observational study was to investigate the relation between the frequency of critical neuromonitoring parameters (brain tissue pO2, (PtiO2) < or = 10 mmHg, intracranial pressure (ICP) > 20 mmHg, cerebral perfusion pressure (CPP) < or = 70 mmHg) and outcome after severe aneurysmal subarachnoid hemorrhage (SAH). In a prospective study on 42 patients monitoring of ICP, CPP, and PtiO2 (in the area at risk for vasospasm) was performed. All patients were primarily classified as Hunt and Hess grade 4 or with secondary deterioration to this grade. Relative proportions of PtiO2 < or = 10 mmHg (n = 42), ICP > 20 mmHg (n = 25) and CPP < or = 70 mmHg (n = 23) were derived from multimodal neuromonitoring data sets for different time intervals, i.e. 1. the total monitoring time; 2. the total monitoring time without the last two monitoring days; 3. the second last monitoring day; and 4. the last monitoring day. Patients were divided into nonsurvivors (GOS = 1) and survivors (GOS = 3-5). For the total monitoring time, significant differences in the relative proportion of critical values were found for all neuromonitoring parameters (p < 0.05). The detailed analysis of consecutive time intervals revealed significantly increased proportions of critical values in nonsurvivors for all neuromonitoring parameters during the last day only. Additionally, ICP > 20 mmHg was significantly more frequent during the second last day (p < 0.01). For other time periods no differences were observed. We conclude, that critical neuromonitoring values are not early predictors of nonsurvival in patients suffering from severe SAH.

Adult↗

Functional hemodynamic monitoring.

Hemodynamic monitoring is a central component of intensive care. Patterns of hemodynamic variables often suggest cardiogenic, hypovolemic, obstructive, or distributive (septic) etiologies to cardiovascular insufficiency, thus defining the specific treatments required. Monitoring increases in invasiveness, as required, as the risk for cardiovascular instability-induced morbidity increases because of the need to define more accurately the diagnosis and monitor the response to therapy. Monitoring is also context specific: requirements during cardiac surgery will be different from those in the intensive care unit or emergency department. Solitary hemodynamic values are useful as threshold monitors (e.g. hypotension is always pathological, central venous pressure is only elevated in disease). Some hemodynamic values can only be interpreted relative to metabolic demand, whereas others have multiple meanings. Functional hemodynamic monitoring implies a therapeutic application, independent of diagnosis such as a therapeutic trial of fluid challenge to assess preload responsiveness. Newer methods for assessing preload responsiveness include monitoring changes in central venous pressure during spontaneous inspiration, and variations in arterial pulse pressure, systolic pressure, and aortic flow variation in response to vena caval collapse during positive pressure ventilation or passive leg raising. Defining preload responsiveness using these functional measures, coupled to treatment protocols, can improve outcome from critical illness. Potentially, as these and newer, less invasive hemodynamic measures are validated, they could be incorporated into such protocolized care in a cost-effective manner.

Blood Pressure Determination↗

Evoked potential monitoring in carotid surgery: a review of 994 cases.

Intraoperative monitoring of brain function is desirable in carotid artery surgery to detect possible complications, but the monitoring methods must be simple to perform, sensitive, and reliable. Median nerve somatosensory evoked potential (SEP) monitoring fulfills these criteria. Between 1985 and 1990, we performed 994 operations of the carotid artery with SEP monitoring. In 92% of the cases, we were able to obtain viable SEP tracings. In seven cases, irreversible SEP loss was followed by a new neurologic deficit. In one case only, neurologic complications ensued without SEP loss. Although immediate intraoperative therapeutic options are limited, the monitoring enhances patient security by allowing intraoperative detection and postoperative analysis of complications. SEP monitoring appears to be at least as effective as conventional EEG monitoring. The viability, sensitivity, and reliability of newer methods, such as modified spectral EEG analysis, must be measured by this established procedure.

Carotid Arteries↗

Complications of invasive video-EEG monitoring with subdural grid electrodes.

OBJECTIVE: To evaluate the risk factors, type, and frequency of complications during video-EEG monitoring with subdural grid electrodes. METHODS: The authors retrospectively reviewed the records of all patients who underwent invasive monitoring with subdural grid electrodes (n = 198 monitoring sessions on 187 patients; median age: 24 years; range: 1 to 50 years) at the Cleveland Clinic Foundation from 1980 to 1997. RESULTS: From 1980 to 1997, the complication rate decreased (p = 0.003). In the last 5 years, 19/99 patients (19%) had complications, including two patients (2%) with permanent sequelae. In the last 3 years, the complication rate was 13.5% (n = 5/37) without permanent deficits. Overall, complications occurred during 52 monitoring sessions (26.3%): infection (n = 24; 12.1%), transient neurologic deficit (n = 22; 11.1%), epidural hematoma (n = 5; 2.5%), increased intracranial pressure (n = 5; 2.5%), and infarction (n = 3; 1.5%). One patient (0.5%) died during grid insertion. Complication occurrence was associated with greater number of grids/electrodes (p = 0.021/p = 0.052; especially >60 electrodes), longer duration of monitoring (p = 0.004; especially >10 days), older age of the patient (p = 0.005), left-sided grid insertion (p = 0.01), and burr holes in addition to the craniotomy (p = 0.022). No association with complications was found for number of seizures, IQ, anticonvulsants, or grid localization. CONCLUSIONS: Invasive monitoring with grid electrodes was associated with significant complications. Most of them were transient. Increased complication rates were related to left-sided grid insertion and longer monitoring with a greater number of electrodes (especially more than 60 electrodes). Improvements in grid technology, surgical technique, and postoperative care resulted in significant reductions in the complication rate.

Adolescent↗