Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MONITORING SYSTEMS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70Linked to original sources

[Application of non-invasive hemodynamic monitoring on high-risk surgical patients in the early stages after emergency admission].

OBJECTIVE: Pulmonary artery (PA) catheterization monitoring (Swan-Ganz) is usually not available to critically high-risk surgical patients before admission to ICU, where action to correct values derived from such monitoring may be too late. To explored the effect of non-invasive monitoring systems that allow hemodynamic monitoring during the early stages after trauma. METHODS: The early temporal hemodynamic patterns after high-risk trauma with non-invasive monitoring systems were evaluated, and compared these to invasive PA monitoring. The study included 156 patients monitored shortly after admission to the emergency department. RESULTS: The non-invasive impedance cardiac output estimations under extenuating emergency conditions were similar to those of the thermodilution method: r=0.69, r(2)=0.87, P<0.001; bias and precision were (0.62+/-0.38)L. min(-1).m(-2). In ICU, these values improved further to: r=0.84, r(2)=0.93, P<0.001; bias and precision were (0.36+/-0.15) L.min(-1).m(-2). Monitoring revealed episodes of hypotension, low cardiac index, arterial hemoglobin desaturation, low transcutaneous oxygen and high transcutaneous carbon dioxide tension, and low oxygen consumption during initial resuscitation. Low flow and poor tissue perfusion were more pronounced in non-survivors by both METHODS. CONCLUSION: Multicomponent non-invasive monitoring systems offer continuous on-line, real-time display of hemodynamic data, they allow early recognition of circulatory dysfunction. Such systems provide information similar to that provided by the invasive thermodilution method, and are more effective and safer.

Adult↗

The LifeShirt system for wireless patient monitoring in the operating room.

We examined the functionality and reliability of a wearable physiological monitoring system (LifeShirt) during normal daily activities and in a hospital operating room (OR) environment. The garment collects physiological data such as oxygen saturation, and stores them in a recorder from which it can be read afterwards. Ten normal subjects wore the shirt continuously for 8 h per day. Feedback from the testers was quite positive, although the collected data varied in quality. Ten hospital patients also wore the shirt during endoscopy. The data collected during the hospital stay were qualitatively adequate. Measuring respiratory function caused the biggest problems. The study showed that intelligent garment technology could be used in an OR environment for patient monitoring, albeit not in realtime. It may also be useful in home follow-up.

Activities of Daily Living↗

[Estimation of the intake of food additives--methods applied in the European Union].

Guidelines for estimation of food additives intake were prepared by Codex Committee on Food Additives and Contaminants (CCFAC) in 1989. During the period 1994, 1995 three specific directives have been adopted, each of them including an obligation for Member States to introduce systems to monitor the usage and consumption of food additives and to report their findings to the Commission. Recommendations of Commission's experts which should be taken into account for preparing the monitoring system by Member States are based on decision tree, which systematizes proceeding procedures. Above mentioned decision tree might be a tool for elimination of the food additive which intake does not pose a health hazard. ADI (Acceptable Daily Intake) plays the essential role in the risk assessment of food additives intake. The food additives, which were not eliminated during the decision tree considerations require detailed revision of the conditions of their use. Poland, as a Candidate Country for EU, after the accession will also be obligated to introduce the system to monitor the usage and consumption of food additives and to report relevant report to the Commission.

Decision Trees↗

Effect of formulation variables on the floating properties of gastric floating drug delivery system.

PURPOSE: To evaluate the contribution of formulation variables on the floating properties of a gastric floating drug delivery system (GFDDS) using a continuous floating monitoring system and statistical experimental design. METHODS: A modified continuous floating monitoring system, which consisted of an electric balance interfacing with a PC, was designed to perform the continuous monitoring of floating kinetics of GFDDS. Several formulation variables, such as different types of hydroxypropyl methylcellulose (HPMC), varying HPMC/Carbopol ratio, and addition of magnesium stearate, were evaluated using Taguchi design, and the effects of these variables were subjected to statistical analysis. RESULTS: The continuous floating monitoring system developed was validated, using capsules with different density, and a good correlation between theoretical and experimental values was obtained (R2 = 0.9998), indicating the validity of the setup. The statistical analysis indicated that magnesium stearate had a significant effect on the floating property of GFDDS (p < 0.05), and addition of magnesium stearate could significantly improve the floating capacity of the GFDDS. It was found that the HPMC of higher viscosity grade generally exhibited a greater floating capacity, but the effect was not statistically significant. For polymers with the same viscosity, i.e., K4M and E4M, the degree of substitution of the function group did not show any significant contribution. A better floating behavior was achieved at higher HPMC/Carbopol ratio. Carbopol appeared to have a negative effect on the floating behavior of GFDDS. CONCLUSIONS: It was concluded that by using a validated continuous floating monitoring system, the effect of formulation variables on the floating property of the delivery system and their ranges could be identified. Incorporation of hydrophobic agents, such as magnesium stearate, could significantly improve the floating capacity of the GFDDS.

Acrylic Resins↗

Detection of bacteraemia by the continuously monitoring BacT/Alert system.

AIMS: To analyse a continuously monitoring blood culture system with respect to the time to detection of various groups of organisms, their clinical importance, and the relative efficacy of the aerobic and anaerobic bottles. METHODS: Four thousand blood cultures were monitored and the information relating to the positive cultures was noted and analysed. RESULTS: Four hundred and seventy seven blood cultures were detected as positive, 81% (387/477) of which were detected within 48 hours. The most pathogenic organisms were detected in the shortest period, less pathogenic later and those generally regarded as contaminants last. Clinically important isolates were also detected earlier. Many positive blood cultures were detected in only one bottle of the set, even those regarded as clinically important. CONCLUSIONS: The management of continuously monitoring blood culture systems could be improved by considering time to detection trends. Clinicians should be aware of the relatively rapid detection of clinically important, positive blood cultures in relation to patient treatment.

Automation↗

Cloning of environmental genomic fragments as physical markers for monitoring microbial populations in coking wastewater treatment system.

The association between community functional shift and dynamics of genomic DNA composition can be used to identify functionally relevant populations as indicator organisms for systems monitoring. In this work, fingerprinting-based community DNA hybridization was used to monitor community structural dynamics and identify genomic fragments whose abundance shifts were concomitant to changes in COD removal capacity in a reactor. A laboratory-scale anaerobic-anoxic-oxic fixed biofilm system treating coking wastewater was operated with (LR mode) or without effluent recirculation (LNR mode). The contribution to total chemical oxygen demand (COD) removal by the anoxic reactor increased from 4% in LNR mode to 26% in LR mode. Long primer RAPD (randomly amplified polymorphic DNA) community fingerprints of the anoxic reactor also changed most significantly from the one similar to the anaerobic reactor to one similar to the oxic reactor. DNA hybridization revealed one signature band of 2.1 kb shared by the anoxic and oxic reactors in LR, but not LNR mode. Clone library profiling of this band resulted in one predominant 2.1-kb genomic fragment (B3) with no homologous sequences in GenBank. Real-time polymerase chain reaction indicated that copy numbers of B3 in the anoxic reactor under LR mode were 69 times higher than that under LNR mode, concomitant to a significant increase in COD removal capacity in this reactor. The different patterns of distribution of B3 in the laboratory system and a comparable malfunctioning industrial system demonstrated the potential of this genomic fragment as physical markers in systems monitoring. In addition, this genomic fragment may allow sequence-guided isolation of the host microbe.

Bacteria↗

An integrated noninvasive system for monitoring the microcirculatory effects of vasoactive drugs: an experimental study.

BACKGROUND: No information is available on the effects of vasoactive drugs on the microcirculation and on the correlation between their effects on the capillary and the systemic circulation. PURPOSE: To characterize the effects of nitroglycerin (NTG), nitroprusside (NP), and metaraminol infusion on microcirculatory variables using a noninvasive monitoring system. METHODS: Increasing doses of NTG (5-40 microg/kg/min) and NP (5-20 microg/kg/min) were intravenously infused to eight rabbits. The microcirculatory parameters were monitored by a combined noninvasive system which included laser Doppler flowmetry (LDF), photoplethysmograph (PPG), and transcutaneous oxygen tension (tc-PO2). Mean blood pressure (MBP) was measured simultaneously. RESULTS: At maximal rate of NTG infusion, the values of LDF, PPG, tc-PO2, and MBP were 72.2 +/- 23.9, 234.7 +/- 165.6, 103.5 +/- 37.4, and 82.7 +/- 7.4% of baseline, respectively. Following NP infusion the LDF, PPG, tc-PO2, and MBP reached 70.8 +/- 24.1, 190.5 +/- 68.9, 70.0 +/- 14.7, and 75.6 +/- 14.6% of baseline, respectively. The tissue oxygenation was significantly reduced during NP infusion compared to NTG (P < 0.05). The values gradually returned to the baseline 10 min after termination of NP infusion, but not after NTG. After injection of 1 mg metaraminol there was a steep decline in LDF, PPG, and tc-PO2 parallel to a significant increase in MBP. When metaraminol was administered after injection of 0.1 mg phenoxybenzamine, these changes were abolished. CONCLUSIONS: This noninvasive system effectively monitors microcirculatory hemodynamic changes induced by vasoactive drugs. NTG and NP cause similar changes in the systemic and microcirculatory bed, with the exception of peripheral oxygenation, which is reduced only during infusion of NP. The changes in the microcirculatory bed following metaraminol and phenoxybenzamine imply that their effects on the arterioles are mediated by adrenergic alpha-receptors.

Analysis of Variance↗

Bioartificial liver process monitoring and control systems with integrated systems capability.

Monitoring and control of a bioartificial liver (BAL) support system have the potential to allow for maximization of device bioactivity and protection of both patient and device from untoward consequences of a complex hemoperfused fluidic process, such as coagulation, leakage, or decreased metabolic output. In this work, an integrated embedded systems controller and associated experimental platform were developed to allow for simultaneous monitoring and control of the physical environment of the BAL support system to ensure optimal and sustained hepatic metabolic function and to allow for simplified recording of experimental data. The user interface and core embedded system kernel were developed with rapid prototyping software tools and allowed for operation of easily modified user interface panels. BAL environment monitoring consisted of real-time recording of ambient and reactor temperatures, reactor inlet pressure, the presence of bubbles in the prereactor inlet tubing, and aqueous oxygen tension. Environmental parameters under direct real-time control included reactor inlet flow rate, ambient temperature, and adaptive control of flow rate in response to changes in either inlet pressure or outlet oxygen tension. Use of embedded system integration techniques will facilitate subsequent BAL studies that are dependent on scale-up of reactor size and number, fluidic complexity, and the degree of parallelism such as large animal studies and, ultimately, human clinical studies. In addition, further studies of the effects of flow rate, shear, oxygenation and metabolic substrate on real-time cellular respiration can be pursued with the use of real-time ruthenium oxymetry, as described in this article.

Animals↗

Heroin epidemics revisited.

This paper reviewed heroin use data from the US government's epidemiologic monitoring system for substance abuse. The monitoring system has multiple components, i.e., the Drug Abuse Warning Network of reporting emergency rooms (9), annual surveys of high school and post-high school youth (3, 4), annual National Household Surveys of Substance Abuse (7, 8, 50), Drug Use Forecasting (51), the Community Epidemiology Work Group (52), and law enforcement systems not reviewed here. These monitoring systems should identify any major increase in heroin incidence in this country relatively early. This is important, because the early stages of heroin epidemics are often hidden from society, and the epidemics are already full-blown by the time health and other agencies become aware of the size of the affected population and are required to respond. The hidden or underground nature of heroin epidemics is caused by 1) the need of each user to hide an illegal activity and 2) the delay between the time when heroin is first used and the onset of physical dependence and other adverse consequences, which bring new heroin addicts to the attention of treatment and enforcement systems. Despite an epidemiologic surveillance system which should rapidly identify large-scale heroin spread in this country, our treatment and law enforcement systems are not organized to respond rapidly to contain an epidemic. Substance abuse treatment services are not structured for rapid expansion and contraction based on fluctuating need. Apart from HIV prevention programs, we do not have outreach teams attached to treatment programs that could quickly identify local outbreaks and involve new heroin abusers in treatment (10).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Chronobiology of Aging in Albizzia julibrissin: I. An Automated, Computerized System for Monitoring Leaflet Movement; The Rhythm in Constant Darkness.

We are using leaflet movements in Albizzia julibrissin as a model system for investigating the chronobiology of aging. To monitor leaflet movements during long dark periods with adequate temporal and spatial resolution, we designed an automated, computerized photoelectric monitoring system. Each of 12 leaflet pairs was positioned in an individual light-proof container, with one leaflet immobilized. The angle of the mobile leaflet was monitored by a photosensor array using a low intensity infrared beam. Leaflet position was determined by custom-developed software, using information on the shading patterns of the sensors. Data on leaflet angle as a function of time were collected and stored on a floppy disc and then printed in numerical and graphical form.Oscillations of young, middle-aged, and old leaflets persist during 7 d of darkness with a periodicity close to 24 h. Period length appears to be age-independent, but rhythmic wave form is age-dependent. The older the leaflet, the earlier and more completely it opens and the less completely it closes.

Journal Article↗

Technical note: a computerized system for monitoring feeding behavior and individual feed intake of dairy cattle.

The objective of this study was to develop and validate a computerized system to monitor feeding behavior and feed intake of loose-housed dairy cattle. The system consisted of 28 scales located in front of each self-locking place of a regular feedbunk. All cows had access to all scales indifferently. Each visit to the feedbunk was monitored by a transponder in the ear of each cow that was detected by a proximity reader located at the top right corner of each headlock. The data from the scales and the proximity readers were continuously recorded by a computer with an average scanning time of 3.5 s. The monitoring system was validated using all 28 feeding places and 51 lactating cows in a series of 4-h observations during 5 different d. During the observation periods, for each feeder, 2 observers recorded the cow number and the exact time of the visit. The observed data were then compared with the computer records. To validate the ability of the system to monitor feed consumption, on separate days, the amount of feed consumed by a cow during a visit was also measured manually with an external scale, and the feed that disappeared from each scale in 2 different 24-h periods was compared with the sum of feed consumed in each scale during these 2 periods. The average time spent in a given scale by each cow determined by direct observations was similar to that determined by the computer. The system was accurate and showed a high specificity (98.8%) and sensitivity (99.6%) for cow detections. Feed weights determined by the computer system were similar to those measured manually with an external scale, implying that the system was also accurate in measuring individual intake weights. In conclusion, the system provided a reasonable estimate of the number of visits per animal, length of each visit, amount of feed consumed per visit and animal, the total amount of feed consumed daily by each animal, and the rate at which animals consume feed.

Animals↗

[Continuous glucose monitoring: different systems, different ambitions].

This paper describes the current approaches towards the development of continuous glucose monitoring system, in which glucose is measured either in blood or in the subcutaneous tissue. These systems may be used as a glycemic holter, or to display continuously the changes in glucose level, to trigger an alarm in case of hypoglycemia, or of risk of hypoglycemia, or finally to pave the way to the development of an artificial beta cell.

Blood Chemical Analysis↗

A new all-season passive sampling system for monitoring H2S in air.

A new Maxxam All-Season Passive Sampling system for monitoring H2S in air has been developed. This passive sampling system employs the same approaches as the Maxxam All-Season Passive Sampling Systems for monitoring SO2, NO2, and O3 reported previously. This system has been extensively tested in the lab (temperature from -20 to 20 degrees C, relative humidity from 30 to 84%, and wind speed from 0.5 to 150 cm/s) and validated in field studies. Comparing measurements obtained with the use of the new passive sampling system with equivalent measurement with the use of an active filter pack H2S sampler yielded an accuracy of greater than 85%. The new H2S passive sampling system can be used to measure ambient H2S concentrations ranging from 0.02 to 7 ppb based on a 1-month exposure period. There is no significant interference found from other sulfur compounds in air. This system has been used in many air monitoring projects.

Air Pollutants↗

A simplified procedure for continuous intraoperative external monitoring of systemic leakage during isolated limb perfusion.

AIMS: Isolated limb perfusion (ILP) with high doses of an alkylating agent alone or in combination with tumor necrosis factor (TNF) in hyperthermic conditions (HAP) has been proposed for the treatment of locoregional tumors. A critical step in ILP/HAP is accurate monitoring of systemic leakage to prevent the toxic effects of chemotherapy, and in particular of TNF. Ten percent systemic leakage from the perfusion circuit is considered the maximum acceptable leakage. In this study we report our experience of a new leakage monitoring system. MATERIALS AND METHODS: Ths new simplified procedure is based on the use of 99mTc-labeled soluble human serum albumin (HSA) and a hand-held gamma probe as detector. The procedure consists of the following steps: 1) A standardized 99mTc-HSA dose of 0.5 MBq/kg body weight is injected into the perfusion circuit before chemotherapy/TNF perfusion and a hand-held gamma probe (IGP) is placed over the precordial area in a zone that was marked on the skin during a simulation test; 2) 48-72 hours before ILP/HAP a complete simulation test is performed with a 99mTc-HSA dose corresponding to 10% of the total dose calculated for the patient's body weight; 3) during the simulation test the maximum count-rate zone on the precordial area is detected by IGP and marked on the patient's skin; 4) a 60-min curve of effective 99mTc-HSA radioactivity decay (physical and biological) is calculated and fitted; 5) to compare external counting with the effective circulating radioactivity, patient blood samples and circuit blood samples are taken every five minutes during ILP/HAP and measured by a laboratory gamma counter and very convenient thanks to the favorable characteristics of IGP. The placed in the operating room. RESULTS: External counting with a hand-held gamma probe was easy to perform time/activity curves obtained during simulation tests showed a regular and constant effective decay with a mean decay rate of 30% at 60 minutes compared to baseline values. The external measurements obtained by IGP proved to be well correlated with blood samples measured in vitro by a laboratory gamma counter. The results of this procedure, in particular the data of the simulation test for each patient, allowed us to correct the limit of 10% maximum leakage during ILP/HAP in accordance with the time/activity curve. CONCLUSIONS: Although 99mTc-HSA has some unfavorable characteristics, it offers many advantages over 131I-HSA. The procedure proposed by us, which was based on the use of an IGP and 99mTc-HAS at a standardized dose of 0.5 MBq/kg body weight and on an individual simulation test for each patient performed 48 hours before ILP/HAP, proved to be simple and accurate in monitoring systemic leakage during ILP/HAP anti-cancer therapy.

Chemotherapy, Cancer, Regional Perfusion↗

Correlation of continuously monitored regional cerebral blood flow and brain tissue oxygen.

BACKGROUND: The purpose of this study was to investigate the relationship between continuously monitored regional cerebral blood flow (CBF) and brain tissue oxygen (PtiO2). METHODS: Continuous advanced multimodal neuromonitoring including monitoring of PtiO2 (Licox, GMS) and CBF (QFlow, Hemedex) was performed in eight patients after severe subarachnoid haemorrhage (n=5) and traumatic brain injury (n=3) for an average of 9.6 days. Parameters were measured using a flexible polarographic PtiO2-probe and a thermal diffusion CBF-microprobe. FINDINGS: Regarding the whole monitoring period in all patients, the data indicated a significant correlation between CBF and PtiO2 (r=0.36). In 72% of 400 analysed intervals of 30 minutes duration with PtiO2 changes larger than 5 mmHg, a strong correlation between CBF and PtiO2 existed (r>0.6). In 19% of intervals a still statistically significant correlation was observed (0.3<r<0.6). During the remaining 9% no correlation was found (r<0.3). Regarding the clinical stability of the monitoring devices, the CBF monitoring system allowed monitoring of CBF in 64% of the time when PtiO2 monitoring was possible only. Phases of non-monitoring were mostly due to fever of the patient, when the system does not allow monitoring to avoid overheating of the cerebral tissue. CONCLUSIONS: This study suggests a correlation between CBF and PtiO2. The level of PtiO2 seems to be predominately determined by regional CBF, since changes in PtiO2 were correlated in 90% of episodes to simultaneous changes of CBF.

Brain↗

Determination of PAH in airborne particulate: comparison between off-line sampling techniques and an automatic analyser based on a photoelectric aerosol sensor.

The automatic analyser is based on a photoelectric aerosol sensor, with continuous sampling and an on-line detection system. Traditional sampling monitoring systems consist of collecting airborne particulate on filters; the sample is then extracted, purified and analysed. It is possible to identify each compound and to determine its relative abundance in the total particulate matter, on the other hand, this method requires great complexity of analysis. Continuous monitoring systems allow getting quicker results to compare with threshold levels. It is also possible to obtain an easier correlation with factors such as traffic flows or meteorological conditions. However, such systems cannot quantify single compounds, and data are expressed as total PAH. The comparison between the results shows a satisfactory linearity between the data obtained with the two methods. The difference of about one order of magnitude between the data obtained with photoelectric aerosol sensor (PAS) system and the sum of the concentrations of selected PAHs determined with off-line methods can be explained with the different selectivity of the two methods employed. This work has been developed in Aosta, the administrative centre of the Aosta Valley district.

Aerosols↗

[Human vital function monitoring as a system with hybrid intelligence].

Monitoring system is considered in this work as a reanimatologist-monitor-patient-medium system. This work is an upgrade to the previous concept of monitoring systems as systems with hybrid intelligence acting under variable conditions of object and medium. Human cardiorespiratory system was considered within the framework of the P. K. Anokhin theory of functional systems. The problem of resuscitation was formulated for this system and volume of required information was determined. Environment characteristics in resuscitation and surgery departments were considered. The requirements for monitor were formulated on the basis of analysis of these systems. The law of mutual adaptation of reanimatologist and monitor was put forward and safety problems associated with human factor were considered. Implementation of these principles in the MITAR 01-R-D is described.

Artificial Intelligence↗

Measurement and prediction of medication compliance in problem drinkers.

BACKGROUND: A variety of methods have been used to measure medication compliance. Although electronic monitoring has been considered to be the best method, it has some potential for error and its high cost may limit its feasibility. This study examined the concordance of data on medication compliance that was obtained by using an electronic monitoring system (Medication Event Monitoring System, or MEMS), daily diary reports, and tablet counts. METHODS: Subjects were 150 problem drinkers participating in a pharmacotherapy trial. Subjects were randomly assigned to receive naltrexone 50 mg (n = 75) or placebo (n = 75) and to receive either daily (n = 72) or targeted (n = 78) medication administration. Comparisons between methods were conducted at the aggregate and individual daily levels, and the association between compliance and three alcohol-related outcomes was evaluated. RESULTS: Daily diaries showed good day-to-day concordance with MEMS and a higher correlation with MEMS than did tablet counts. However, high-compliance subjects did no better than low-compliance subjects on any of three alcohol-related outcome measures. CONCLUSIONS: Compliance measurement using a daily diary method yielded results that are comparable to those obtained with electronic monitoring, which served as a criterion measure. In contrast, tablet counts provided data that were less concordant with the criterion measure. The unique nature of the study sample (i.e., the majority of subjects were not committed to a goal of abstinence), combined with the targeted approach to treatment, may explain the lack of association between compliance and alcohol-related outcomes. Further research should aim to ascertain the factors affecting the relationship between compliance and outcomes.

Adult↗